Home

USER`S MANUAL

image

Contents

1. 3 3 While the appliance is in work mode the green indicator goes off and the flame starts to appear The device works automatically until they run out of fuel or disable the device by the user C Flame size regulation The Zen High can operate in two modes Normal and ECO The device always starts with a standard flame size The device has the adjustable flame size during operation In order to reduce the height of the flame press the ECO button You will hear two beeps and the ECO button will be highlighted The unit is now operating in ECO mode To return to the normal height of the flame press the ECO button you will hear one beep and the ECO button backlight turns off The device is now in normal mode ATTENTION It might take a few moments for the flame to adjust ATTENTION The device switches to ECO mode by itself when there is a danger of over temperature of the device D Device extinguishing Press the START STOP button on the control panel You will hear two beeps and the red indicator will start to blink The flashing red indicator means that the device is too hot to be restarted When the device cools the message will disappear and depending on the amount of the fuel in the tank either the green indicator will flash and indicate the readiness for operation or the blue indicator will indicate the lack of the fuel E Subsequent start up If the blue indicator is flashing on the control panel start from the point B 2
2. If the green READY indicator is flashing on the control panel you can e start form the point B 3 e open the fuel filler bolt the green READY indicator will go off If the blue indicator blinks and a beep sounds intermittently the tank is full and it is not allowed to pour any more fuel Close the fuel filler bolt and proceed in accordance with section B 3 the blue indicators flashes you can refuel see section B 2 and turn on the device see section B 3 or close the fuel filler bolt and activate the device by following the point B 3 F Information and warning alert In order to increase safety the Zen High is equipped with an electronic system to keep the operation safe In the case of a dangerous situation the device immediately triggers alarms CAPTION The indicator is off The indicator flashes The indicator is blinking Copyright Planika Sp z 0 0 www planikafires com 6 Copyright Planika Sp z 0 0 Information and warning alerts oe SIGNALS Control Panel Indicators Ton o If the fire is not visible NO POWER If you see a fire the device is in operation The device is ready for operation No fuel in the tank Initial start up of the device The device is protected against too rapid restart when the fireplace is cooling down or the allowable temperature has been exceeded the fireplace will turn off The device automatically turns off due to lack of fuel
3. e it will be necessary to clean elements not normally available The manufacturer is not liable for damage resulting from improper operation non manual self dismantling attempts to modify El using other liquids than those recommended in point II Fuel VI Disposal and recycling The product is equipped with parts made of aluminium steel plastics and electronics If you need to dispose of the device follow the terms of disposal and recycling in force in your country Moreover dispose of the empty Fanola containers should be dumped to plastic waste baskets Most of the materials used in Planika appliances can be recycled FANOLA fuel recommended for this product has received following certification ecoftuel If you have any technical problems or other questions that need clarification contact your dealer Copyright Planika Sp z 0 0 www planikafires com 8
4. in the tank The fuel tank is full There was a fuel spill or the acceptable device operation temperature has been exceeded Operation error The device temperature below 10 C or critical operation error www planikafires com Make sure the device is properly connected to the power supply Do not leave the device unattended by an adult You can run the device in accordance with section B 3 Fill the fuel in accordance with B 2 paragraph Wait for the appearance of fire the light goes off Allow the device to cool down After cooling the device the red indicator will turn off and the green indicator will start to flash Allow the device to cool down After cooling the device the red indicator will turn off It is not allowed to pour any more fuel Close the Fanola filler bolt The blue indicator will turn off the green one will start to flash Immediately stop pouring the fuel Remove the funnel dry a visible moisture Press the START STOP button to turn off the sound If the spillage is excessive the source of power needs to be disconnected With the use of the manual pump supplied by the manufacturer pump out at least 1 liter of fuel from the fuel filler Wait at least 1 hour to evaporate the remaining moisture and then close the fuel filler bolt Hold the ECO button for about 5 seconds If the alarm message reappears wait a little bit longer until the rest of the moisture evaporates If the message rea
5. olanika NTELLIGENT FIRE USER S MANUAL ZEN High Manufactured by Planika Sp Z 0 0 ul Bydgoska 38 36 061 Brzoza Poland Edition 10751 02 as of 11 05 2015 IT IS OBLIGATORY TO READ AND KEEP THIS INSTRUCTION MANUAL TABLE OF CONTENTS k GENERA Mormaii sana a ii A dabas 3 O A A E IA 3 TA te aslo nla ae oe eeloe te Ae nae ed ede eee eae he ein 3 IV Operation Operating elements rios ada ee eee eee erste 4 Mitial Start Op Of the Te Nica a aE Shs Row ee 5 Flame Size regulado aE N 6 N dedo dabas dardo ate 6 Device ext CUISINE AA a 6 Subsequent start UD ar ias E pb es 6 Information and Warning alert ooo ooo oooo 6 V Cleaning and MaintenanCe s lt ii idas ie ii ei eS a da do 8 WI Disposal iNd TECVCINS 200 A A A a 8 Copyright Planika Sp z 0 o www planikafires com 2 I General information The ZEN HIGH is a decorative appliance with real flames Due to the innovative technology applied the ZEN is simple and safe to use II Fuel In order for the Zen High to function correctly use the recommended FANOLA liquid or other available on the market and fulfilling the criteria of being a 86 96 denatured ethanol in accordance with the European Union guidelines Directive No 162 2013 Using other liquids is prohibited as it may lead to incorrect functioning of the device damage of the device and or may cause fire or and or health risk The manufacturer takes no responsibility for damage caused by u
6. or dry chemical extinguisher placed nearby the device e The enabled device must not be moved Wait for complete fuel burn out disconnect the power supply and cool down the elements before moving the device e The device should not be left without adult supervision e Prevent handling of the device by persons not trained e Do not attempt to make changes or repairs to the construction of the device on your own Repairs can be made only by a person trained to service the device e Do not pour FANOLA liquid to a furnace as it may cause damage of the device and cause fire Pouring FANOLA liquid to a burning furnace may cause a sudden ignition and can cause fire burns and a risk to life e Do not heat the FANOLA liquid before starting up the device e Do not start up the device if the FANOLA liquid spilled out from the container e Do not cover the working device as it may cause fire e Keep the device and fuel away from children pets and unauthorized persons e FANOLA liquid is not suitable for consumption Avoid contact with skin and eyes e Do not operate by the filler when the device is running e Do not tamper with the elements inside the furnace body at the risk of burns damage to the device or fire e Some elements of the device heat up to high temperatures Do not touch the area of the furnace of the device as it may cause burns Copyright Planika Sp z 0 0 www planikafires com 3 e Do not place any decorative elements on the burne
7. ppears contact your service provider If the alarm message appears during the start of the device press the START STOP button to turn off the sound and hold the ECO button for about 5 seconds If the message reappears contact your service provider Press the START STOP button to turn off the sound and hold the ECO button for about 5 seconds If the message reappears contact your service provider Press the START STOP button to turn off the sound Provide higher ambient temperature Wait until the device obtains the indoor temperature Hold down the ECO button for about 5 seconds If the message reappears contact your service provider Shut the filler bolt Press the START STOP button to turn off the sound and hold the ECO button for about 5 seconds If the message reappears contact your service provider Filler bolt protection error V Cleaning and maintenance Switch off the device before cleaning Wait until the temperature of the device gets close to the ambient temperature To maintain appropriate technical condition of the device please observe the following rules e Clean the furnace with a soft cloth and water to avoid causing cracks and scratches When purchasing and dozing cleaners be sure to protect the environment and comply with the recommendations of manufacturers It is forbidden to clean the inside of the device by unauthorized persons The manufacturer does not foresee a situation wher
8. r The green indicator Copyright Planika Sp z 0 0 www planikafires com 4 B Initial start up of the device 1 On the control panel the blue light flashes it indicates the lack of fuel in the tank Please refuel FUEL 2 Refueling 2 1 Open the Fanola filler bolt 2 2 Insert the funnel A 2 3 Pour the fuel into the funnel following these precautions 8 pouring be careful not to spill fuel out of the filler If the fuel is spilled error message is displayed go to step F and follow the guidance provided in the table If the spillage RUEL ey is excessive the source of power needs to be disconnected e If 5L containers are used to fill up twist on the cap with the tap onto the container and pour using the funnel To fill up use only accessories provided by the manufacturer 2 4 Pour the fuel to the point where the blue indicator blinks and the intermittent beep will sound Stop pouring Remove the funnel 2 5 Close the Fanola filler bolt The green indicator will flash on the control panel READY 3 Device extinguishing The green indicator flashes on the control panel O READY 3 1 Press the START STOP button on the control panel and hold for 2 seconds You will hear a single beep Copyright Planika Sp z 0 0 www planikafires com 5 3 2 The green indicator will blink to indicate start up of the device it takes a few moments for the appliance to ignite the flame
9. r s surface e Warning The glowing coil temperature heats up to 1300 C Touching the device while it is turned on may cause burns e Warning The furnace heats up to high temperatures during operation e WARNING The first run can be made only after proper installation of the device and reading the manual instructions e WARNING Prior to moving the appliance burn the fuel out and move the appliance slowly in the horizontal position avoiding shaking There is always some fuel left inside the device and if spilled the sensors might get wet If that happens the appliance will not work until the liquid evaporates IV Operation This manual contains all the information necessary for the proper operation of the Zen High It is obligatory to read and keep this instruction manual Operation of the device is permitted only after the device is properly installed according to the instructions and the manual A Operating elements Base Furnace Tempered glass Fire grate 9 0900000000000000000000000000000000000000000000000000000 Control panel Tempered glass Fanola filler bolt Control Panel Starts the device from standby mode or switches to the standby Switches to ECO mode Service USB input hidden under a cap Planika NEW SENS OF FIRE ECO START STOP FUEL READ ERROR The blue indicator The red indicato
10. sing prohibited liquids such as absolute ethanol I Safety The Zen High produces a real open fire so in order to use the device properly and safely and in order to keep the warranty the following safety rules should be observed e Do not expose the device to weather conditions The product is for internal use only e Please read the device installation manual to avoid placing the device in rooms with a capacity of less than required e While working the device emits heat water vapour and carbon dioxide therefore it is necessary to provide proper ventilation of the interior so that the total air exchange is 1 h e During the device s starting sequence the characteristic smell of the liquid used in the device or the recommended FANOLA liquid e Do not install the device in areas of large drafts of air near fans vents etc e Do not place in areas where there might be a potentially explosive atmosphere of paint vapours industrial dusts etc e Do not use the device at the ambient temperature below 10 C 50 Fahrenheit or higher than 30 C 86 Fahrenheit e Install the device only on a flat horizontal surface Setting on an inclined surface can cause incorrect operation permanent damage to the device or cause fire e No flammable items should be placed in direct contact and within a radius of 1 m 3 28 ft around the device Do not place near curtains net curtains etc e It is obligatory to have a carbon dioxide