Home
06-systemes-export_cata 09-10
Contents
1. 4 4 Pulse oincce e CONT lt lt SOFTWARE SUPPLIED 83510 G DC MOTOR SPEED CONTROL amp This model is designed for the simplified study of a speed feedback on a closed loop with a feedback signal generated either by a tachometric dynamo or by an optical impulsion encoder It consists of a direct current motor which drives a second direct current motor functioning as a generator The signal issuing from this generator is used as an image of the speed The shaft assembly also drives a toothed disc which cuts a luminous barrier the impulses of which are applied to a frequency voltage converter A direct current adjustable source integrated in the model is used as the voltage reference level A switching supply controlled by the error voltage supply the motor ACCESSORIES SUPPLIED 1 set of leads 2mm 2 x 100cm 2 x 30cm 2 x 15cm ref B3510 G Dim 250 x 150 x 30mm Weight 900g This model includes sensors currently used in industry e an optoelectro reflection barrier with its output amplifier e a Hall effect sensor with its output amplifier e an inductive proximity sensor with its output amplifier e facing a metallic mass which the operator progressively displaces using a worm screw The model also includes e an electronic switch consisting of a triac and its electronic control e a dry relay and a reed relay with two coils e two solenoids e one facing the Hall sensor e
2. Temperature sensors and heating control Bej Eny ee ce ee EDUCATIONAL OBJECTIVES Studying the regulation of temperature all or nothing Studying the regulation of temperature with control loop with variable gain Studying of thermal sensors thermocouple thermistor NTC and PTC USER S MANUAL PRACTICAL WORKS Proposed Practical Works e Studying and calibration of a conditioner temperature sensor Studying the gain of the amplifier sensor PTC100 TET ee ee Studying of the offset of the amplifier Gain calibration by a standard 22 ohm resistor Adjusting the offset of the amplifier Thermocouple calibration e Features of temperature transducers e Control of the temperature by hysteresis This option consists of an interface unit a connecting cable e Control of the temperature by feedback and software This software records the temperature readouts for the PT100 NTC and J sensors on the SENSOR model and This model includes 3 temperature sensors NTC thermistor J thermocouple PT100 platinum probe displays them on the computer screen Characteristics such These sensors are attached to a resistance or cooled by a built in fan The resistance and fan are controlled as the all or nothing setting for heating and fan power separately by short circuiting two terminals The screen printed front panel shows actual cabling of electronic supply may also be displayed on the screen circuits such as amplifiers
3. Electronic test boards Contact boards for the design and rapid testing of circuits The double reed contacts of these boards are in nickel plated bronze They are pitched 1 inch 2 54 mm apart in an insulating ABS base Contacts grouped in strips of 5 or 10 can be fully dismantled from the rear Use components or leads with maximum diameter 0 6mm E a a Lal a S558 24S R LOE PAARD ranse J J 1 j rete Sepet a aF REF PAL2420 REF GL12 REF GL48 REF GL24 Model with integrated power supply protected from short circuits PAL2420 O to 15V 500mA continuously variable O to 15V 500mA continuously variable 5V 1A fixed Ref PAL2420 PAL2420S GL12 GL12S GL24 GL245 GL48 GL48s 245x195 245 x 195 20075 200875 278 150 2250 x 150 260 x 240 260 x 240 With safety sockets Micro leads Interface lead Storage box for supplied micro leads leads Special lead to connect the testing boards and any system in diameter 2mm Max current 500mA 8 racks Transparent plastic cover Total capacity of the box 160 micro leads Dimensions 230 x 160 x 30mm Weight 180g ref MICRO B se BROWN GREY ORANGE BLACK PURPLE BLUE ref INTER 2N ee 25cm Black color The flexible wire used for these leads is terminated at each end by a 0 6mm diameter nickel plated plug The electrical contact is excellent 206 C PRODUCTS 2 YEARS GUARANTEE SE NSO RS TRAINING SYSTEMS amp MODELS
4. Students have to find out the pure resistances and inductances of an installation without interrupting its operation and with a view to deciding on the compensation condenser battery to activate via a power factor regu ref PSYJR aise ENERGY study of the 3rd and oth order harmonics EDUCATIONAL OBJECTIVES Studying putting into service getting started and setting of the system Studying of harmonic filtering of orders 3 amp 5 and the power factor Practical corrections of harmonics generated by a speed variator USER S MANUAL PRACTICAL WORKS Unit on wheels consisting of passive filters used for studying the filtering of the third and fifth order harmonics and as a result the increase in the power factor during the use of a speed controller for an AC motor or apparatus with a diode thyristor bridge with a capacitor filter HARMOVAR uses the industrial methods employed for decreasing the harmonic pollution generated by U f type frequency converters or other pollutant receivers with third or fifth order harmonic currents inverter switch mode power supply and discharge lamps The passive filters found there have been specially sized for optimal use and so that the LC type filtering systems can be studied They eliminate third or fifth order harmonic currents and show the effect of the third order harmonic current on the neu tral e The network analyser ref 6830 option on page 239 records the harmon
5. The coils are short circuited two at a time One switch per pos fies sibility or three switches e 3 faults involving coil earthing A coil is earthed One switch per phase or three switches e 1 fault on the brake The power in the parking brake is cut lt a a Unit from the teacher side open door STUDENT SIDE UNIT This lockable area is used for starting up the simulator if authorised by the teacher The transparent door gives the unit a highly didactic appearance The student control panel is simpler than the teacher control panel offering standard normal operation indications This means that fault finding testing and measurement are identical to reality in the field e Overall dims 670 x 750 x 1180 mm Weight 136 kg e Laminated bench top 670 x 750 mm e A casters 80 mm e 3 phase Hypra socket on 5m mains cable Unit from the student side open door CGER GBUCiS 2 EA CUARAMNIEE TRAINING SYSTEMS amp MODELS Motor start up studies DEMARAC is supplied already wired tutorials a diagram and technical instructions Safety leads 4mm supplied The unit can be supplied without the for details with a power of up fo 1500W with powder brakes controlled 0 12VDC and all 1000RPM tachometer generators with O 10V 0 20V or 0 60V outputs FEATURES e Three phase 400V supply voltage e Protected by residual current device circuit breakers and fuses e Set of lamps and push but
6. AONTA 4 20mMA and or potentiometer and or potentiometer a a FEATURES e Connection by means of safety leads e Dim 100 x 80 x 90mm e Cable length 90cm ref PT100 BOX Control Dimensions 290 x 190mm x 135mm 390 x 280mm x 185mm a ib eee PT100 4 20mMA TEMPERATURE CONVERTER Example of use TMPT BOX unit TMPT BOX Temperature probe P L Controls the power in the charge by varying the conduction angle of the thyristors according to the control current of 4 20mA Can be connected directly to the built in PLC unit ref AUTO BOX A e This unit allows the connection of a temperature probe to the 4 20mA input of the PID e Adjustment of the signal gain amp zero thanks 2 potentiometers e Compatibility with the 2 or 3 wires temperature probes see PT100 BOX e Input output connection on safety sockets 4mm e Works without any external supply e DIMS 77 x 106 x 92 mm AS SIRI TR Ss ref TMPT BOX FEATURES e Connection by means of safety leads e Max current output 15A e Dim 100 x 80 x 90mm CSRERODUCT T2 Fok CUARAMNIEE 187 REGULATION All or nothing regulators for regulation deen 4 20mA Input Power output ZLO vm FO COO ge O A z Alarm output 12V DC output m LAMP STANDARD MODEL i TOR2002 BOX Foire Monitonrlantrater Alarm Sortie Alarme corie 4 Dt Sho Sul ref TOR2Z002 BOX e 4 20mA input on safety socket
7. Rs 2 EB ca EE ae is a e SS be ESE Wired door plate and grid for system operation with a PLC Supplied with programming and training software ref CHATO AUTO ET ss iin see T i i tt e e e e E TA Rt fi 41 ref CO DEB Detects water flowing in the PVC pipe of the CHATO circuit An NO or NC contact at the sensor output sends information to a PLC or a contactor Features e Can be fitted in any position e PVC connection Diam 40mm to be stuck on e Switchable potential free contact Sie NO or NC 7 230VAC SESSE Wired door plate and grid for system operation with relay e Electrical connection via a DIN connector lila A ref CHATO REL he ee a ee a a oa ba E obi a se a a es ls hs el l E 4 A moving float in a transparent tube indicates the pump s water flowrate in cubic meter hour Features Upright fitting Measuring scale 0 6 to 6 cubic meter hour Ascending fluid Float and stop PVC connection Diam 40mm to be stuck on a Unit with concealed switches to simulate sensor faults 6 switches linked to 6 sensors Unit fixed onto the system s frame ref CHATO PAN ref FLO DEB SUMMARY AND HELP IN THE SELECTION OF THE DIFFERENT CHATO SYSTEM PRESENTED PAGES 164 TO 167 Ref CHATO 4S T6 Ref CHATO 4 Ref CHATO 4 GD Ref CHATO Simulator with electrical Simulator with electrical Simulator with Operative part only cabinet and monitoring cabinet and monitoring electrical cabinet
8. on touchscreen on PC only 168 C PRODUCTS 2 YEARS GUARANTEE ref ASC89 24 LOGIC CONTROLS IN 24V ref ASC89 05 LOGIC CONTROLS IN 5V TRAINING SYSTEMS amp MODELS ee esai The ASC89 lift is a model which may be connected to a PLC or any microprocessor system lt comprises 24 outputs and 21 inputs You can only use a part of input outputs if you want to do easy programmes MAIN FEATURES e Opening and closing of the doors on each floor is done by electric servo motors e The rear of the lift is visible through the sides and the bottom which are transparent e The route of the lift is sensed at each floor by a photo detectors e Two limit switches high amp low without program control stop the lift if there is an error in the program e All of the buttons and switches are fitted with de bounce circuits e The outputs are protected against the possibility of a short circuit e The rear sliding door is of a transparent Plexiglass design and there is no manual access possible as there is risk of damaging the servomotor The mechanical controls are sturdy and can withstand any likely faults 4 LEVELS 1 electrically opening door 1 photo detector for door closed 1 photo detector for door open EACH LEVELHAS 2 safety limit switches for door open close No control from the program possible 1 button to call the lift up except the 3rd floor with indicator lamp 1 button to call the lift
9. remote telephone or colour touchscreen these control lighting openings blinds gates heating sprinklers etc To familiarize students with the cabling each electrical component is connected using Radio transmitter 2 a terminal strip to its control or receiver mo dule A removable translucent plate covers the connections and protects the electrical contacts Components located on the panel e modular panel equipped with 5 circuit breakers and one differential 30mA e 5 lighting circuits living room kitchen garage garden e 3 motor opening circuits 1 motor roller shutter 1 garage door and 1 gate simulated by 2 boxes with indicator lights e 1 heater 500W 1 radio receiver i F Way switch Way switch 1 Way switch 2 e 1 sprinkler pump simulated by indicator light 1 radio receiver P d with Hal leohone li e 1 remote control by telephone controlling 2 lighting sets or the roller shutter a Pee i ue a oe hi E o aie Dorie All these components are associated with radio transmitters and or receivers SIO Cn Gs en nek 8 ve enone a Serpe lee N scien cero fouchsoresh 0007 pixels tapable o managingune radiocomponenis olhe routed via the school s telephone network or via the public telephone network dwelling with built in tutorial for component configuration 152 CE PRODUCTS 2 YEARS GUARANTEE Features e Power supply 230VAC by 5 metre mains cord e Dimensions of the frame 950 x 50 x 1620mm e Di
10. 0 O o e e 9 5 800 OF 0 8 r 2 2 a E E e e asso ht A 7T i Ga ee wI Ei E o Pos gt oe oe te a E LL al _ e 3 metre mains lead for power supply 230V 50 60Hz single phase e Console dimensions 1000 x 160 x h 300mm Weight 14kg Composition of the console e 1 Start Stop button with indicator light general control e 1 current generator adjustable by potentiometer from 4 to 20mA e 1 magneto thermal RC circuit breaker 30mA e 1 dimmer 230VAC with control 0 1OVDC e 3 pushbuttons NO e 1 dimmer 230VAC with control 4 20mA e 3 pushbuttons e 1 buzzer 24VDC e 2 ON OFF switches NO e 2 3 pole contactors 24VAC 2 auxiliary contacts NO e 2 ON OFF switches e 3 green indicator lights 24VAC e wind sensor binary contact e 3 red indicator lights 24VAC e 1 light sensor binary contact e 1 source of fixed voltage 230VAC 50Hz e 3 limit switches NO e 1 source of fixed voltage 24VDC e Temperature sensor PT100 3 wire output e 1 source of voltage 24VAC 50Hz e 1 voltage generator adjustable by potentiometer from O to 1OVDC e 1 carrying handle Quality control system by vision sensor EDUCATIONAL OBJECTIVES Study and putting into service of a quality control system by vision sensor Creating the wiring for motorized conveyor belt and video and position sensors Using video recognition programming software TEACHING RESOURCES STUDENT amp TEACHER Practical works proposed e Carry out the configu
11. 186 C PRODUCTS 2 YEARS GUARANTEE TRAINING SYSTEMS amp MODELS SRC power control and loads for regulation HEATING UNIT SCR POWER CONTROLS These SCR power units control the power in the charge by varying the conduction time of the thyristors according to the control current 4 20mA The power the output power the control input 4 20mA and the potentiometer can be used on 4mm safety terminals A potentiometer front allows to 4 vary the conduction time ref RH BOX 230V power supply heating unit fitted with a 75W lamp Completely safe thanks to two 4mm double channel terminals The Pt100 temperature probe with a maxi mum diameter of 7mm can be inserted sideways e g PT100 BOX Powered via 230V mains supply or SCR power unit e g GRAD BOX which regulates the light intensity and therefore the temperature in the unit This temperature can be measured by a temperature probe e g PT100 BOX Compatible with resistive loads only Ref CIA GRA30M CIA GRA30T Features e 75W incandescent lamp E27 e Mains power supply via 2 safety terminals e Inlet port can accommodate temperature probe up to 7mm in maximum e Dim 250 x 250 x 110mm PT100 TEMPERATURE SENSOR oes l _ i r mr a k Supply type Single phase 3 phase Main supply 230VAC 3 X 400VAG 220VAC from mains Auxili uxiliary supply for the cooling fan Output voltage 230VAC 3 X 400VAC Max output current 30A 30A
12. 1Hz 50Hz 1 MHz 0 01 fanout 10 TTL load 1 variable signal generator 6 ranges from 1Hz to 1MHz Fanout 10 TTL or CMOS load cs an aS pth 2 x 8 outputs edge O I 1 TTL level e a ee ee E f 4 outputs edge O I 1 TTL or CMOS level each with debounce circuit Fae 2 ra gee ae 1 fixed AC output 6Vrms with overload protection eee a iG Eesha Thumbwheel switch 2 digit BCD code output common point input F a ne Shack a a E 16 x LED indicating high and low logic state 4 sets of independent 7 segment LED display with BCD i A aC pee Tr 3 x LED functioning as a logic probe Ge eet boi aaa oe a 1 speaker with driver circuit Dimensions 400 x 300 x 130 mm Weight 5 8kg ACCESSORIES SUPPLIED e 1680 tie point breadboard which can be easily put into and taken off permutable with the modules e jumpers leads 198 C PRODUCTS 2 YEARS GUARANTEE Logic gates circuits transistors TTL and CMOS logic cir cuits TTL CMOS I O voltage and current measurement experiments Basic logic gate transmission delay mea surement AND OR NAND NOR XOR gate charac teristics Interface between TIL CMOS and CMOS TIL ref DIGITAL1 NOR NAND XOR gate circuits reverser comparator circuit experiments Schmitt trigger open collector gate circuits ref DIGITAL2 Three state gate circuit Adder Arithmetic logic unit Bit parity generator ref DIGITAL3 Adder Subtractor 2 and 3 inputs reverser BCD code
13. Motor operation e Circuit breaker in front of the power source e Mains power on 400V e General residual current circuit breaker protection e 24V mains power on e General emergency stop and Start Stop TCOMIROL e 2 circuit breakers for protecting the three phase and 24V power supply e Cabinet door safety contact control e till open information elast customer information e information request details FEATURES OF THE TEST CABINET pecremicnel hemo e 800 x 600 x 250mm steel cabinet You can also create your own monitoring e Plate on door with actuators and control lamps wired to the HARTING connector e Free spaces for the addition of control accessories DIAM 22 5 7 INCH TOUCHSCREEN COLOUR e High visibility 256 colour TFT screen e Communication via RJ45 connector for the TCP IP ETHERNET network e Adjustable contrast and brightness e 24V DC 0 3A power supply e Dim 130 x 104 x 41mm e Rapid hanging and connection of a grid no bigger than 750 x 550mm e Door safety contact power to the cabinet is cut off automatically if the door is opened e 4 fixed connectors on grid to be wired by students e 4 rapid connection jacks to the sensors controls and motor The systems which include a monitoring function are all supplied KEY OPERATED DOOR OVERRIDE assembled and fully wired Detailed instructions with full features of e Allows the live cabinet to be used with the door open if the switch has been activated each component and tufo
14. SIMULATE e the detection of the 6 water level sensors Features of the PLC supplied e sequential function chart or ladder language programming e 230V mains power supply e 14 inputs 24V DC on terminal e 10 binary outputs 230V 2A on terminal e RJ45 Ethernet output used for connecting the PLC to the IP computer network e The programming software and index in the form of ladder language is supplied The water that comes out of our taps is drinkable and has travelled a long way In some cases it is pumped from rivers and then undergoes various treatment processes before it becomes fit for drinking It flows into a settling basin at the bottom of which the heaviest materials are deposited then it is filtered through layers of sand and sterilised in order to remove bacteria This clean water is then transported by means of pipes and pumping before it is stored in a water tower These provide consumers with a constant pressure The CHATO system enables students to simulate this entire circuit from the stage where water is pumped from rivers to the stage where it arrives in people s homes System characteristics e Frame on wheels e Dim 1500 x 750 x 1970mm e Weight 190kg 164 C PRODUCTS 2 YEARS GUARANTEE TRAINING SYSTEMS amp MODELS EDUCATIONAL OBJECTIVES _ FEATURES OF THE DIFFERENT COMPONENTS Understanding putting into service getting PUMPS amp FLOW CONTROL VALVES SENSO
15. Schneider PLC for the COM version Understanding and use of the supervision on PC for the COM version Understanding of an IP network for the COM version USER S MANUAL PRACTICAL WORKS FIRE DOOR CONTROL SYSTEM EQUIPMENT e 2 resettable manual triggers with diaphragms e 2 optical smoke detectors They can be activated using an aerosol that is supplied with the panel e independent initiating detector fitted with a maintenance free battery 3 hours autonomy with reset push button with operating test push button e 1 door with electric bolt e 1 PLC Schneider Supplied with programming software and communicating software Vijeo Designer ref GES 6 COM EDUCATIONAL OBJECTIVES Understanding and settings of a fire door control system Programming and setting of the Schneider PLC for the COM version Understanding and use of the supervision on PC for the COM version Understanding of an IP network for the COM version USER S MANUAL PRACTICAL WORKS 6S PRODUCTS Z VWeANSS QuAlyalN cle TRAINING SYSTEMS amp MODELS WIRELESS ANTI INTRUSION UNIT INTRUDER ALARM CONTROL SYSTEM EQUIPMENT e 1 radio unit fitted with a siren which can be disabled e 1 radio keypad for receiving informa tion and remote control with LCD display e 2 infrared sensor 12m range e 2 radio remote controller 4 buttons Range 100 to 300m e 2 break contacts for protecting access points doors and w
16. a RJ45 connector Profile view ref GES 41 COM ref GES 41 no communicating without PLC Base on wheels e Dim Lx x H 750 x 670 x 1950mm 130kg e White melamine panel Dimensions 1000 x 750mm Features of the PLC supplied with GES 41 COM e 9 2AVDC inputs 7 binary outputs e Software supplied with ladder language programme e Programming sequential function chart or ladder language e Fully functioning program Supplied e Ethernet connection to the IP computer network Supplied with the supervision software vijeo designer EDUCATIONAL OBJECTIVES Understanding and settings of a security lighting control system with autonomous batteries or a main power supply Making of the wiring of components and security lighting units Understanding of the security lighting units addressing Use of the setting software URA vision Programming and setting of the Schneider PLC for the COM version Understanding and use of the supervision on PC for the COM version Understanding of an IP network for the COM version USER S MANUAL PRACTICAL WORKS Practical works ____ e Settings of the addressable security lighting units with the use of URA vision software e Realization of complete wiring e Measurement of the voltage and current on the main power supply e Test of the different functionalities e Programming and setting of the Schneider PLC for the COM version e Understanding and use of the su
17. a tenth of a degree OPTION INTERFACE amp LOGIFOUR SOFTWARE eae VSITGUR Conirala de FOUR Thernigue g d f er cer t t 4 r h i l 23445 6 10 11 22 29 14 15 i 17 if i9 20 timis Tel Pac Hi Patios deg Haanes s 20 00 m0 01 000 ref LOGIFOUR This PC interface connected to the DB9 outlet and software are used to record and draw graphs of temperature and heating control directly on PC The connection to PC is made by USB ADDITIONAL FUNCTIONS e Digital display of the two variables e Cursor function e Data transfer to plotter e Zoom function OPTION 4 20mA LOOP CALIBRATOR e Programming in of the output span to supply a typical intensity like 4 8 12 16 or 20mA e linear ramps manual ramps auto ramps e Display 5 digits e Carry case user s manual external battery Pack for 6x 1 5V AA batteries e Input for mains adapter DC 12V not included e Dimensions 88x168x26mm Weight 330g ref VA100 RANGE RESOLUTION ACCURACY 4 20 mA IUA 0 025 SUA 0 20mA IUA 0 025 5pA 0 24mA IA 0025 10pA 4 20V ImV 0 05 5mV 0 20V ImV 0 05 5mV 0 24V ImV 0 05 10mV 190 C PRODUCTS 2 YEARS GUARANTEE TRAINING SYSTEMS amp MODELS Air conditionning system Power factor correction system I MADCOS ref CLIMABOX EDUCATIONAL OBJECTIVES Understanding of the functioning of an air conditioning system Performing maintenan
18. between O and 5Vcc Triangular 5Vcc Square 5Vcc TTL 5V 1 VOLTMETER O to 30V analogue impedance 320 kQ 1 UNIVERSAL COUNTER 8 DIGITS Frequencymeter 1Hz to 1OOMHz Periodm tre 0 01ps to 99 999 999us TTL and CMOS Internal External Input 1 MICRO AMMETER 0 to 100 pA analogue impedance 1kQ 1 LOUDSPEAKER 4 ADAPTERS These adapters allow the unit to be connected to an external electronic unit 2 banana inputs of 4mm diameter 2 inputs of female BNC connectors 3 SWITCHES 2 to 2 positions and 1 to 3 positions 6 positions rotary switche 2 POTENTIOMETERS 0 to 1k O to 100kQ Logic test unit MNAC TRAINER Ss a ie eae ref AT104 MICRO LEADS NOT SUPPLIED SEE PAGE 206 AT104 is a test bed intended for learning about logic circuits Several of the commonest circuits are integrated into the test bed They are fed and their inputs outputs are clearly indicated on short sum maries There are 3 inverters 3 exclusive OR 6 AND 6 OR 6 NAND 6 NOR A manual supplied with the test bed shows how to make an RS D bistable a comparison unit a trigger a counter etc Maintenance the cover is removable the standard circuits are easily replaced Dimensions 340 x 265 x 130mm Weight 4 7kg Mains 230V 1 INTERCONNECTION BREADBOARD with 1580 contacts 2 fields of 640 contacts bearing the components 3 fields of 100 feed distribution contacts 4 SUPPLIES immediately next to the board short circuit protec
19. eccloce MACHIN SORTIES h 4 04 m e feds PROFINET ENTREES ana PUISSANCE L PUISSANCE ooolooo ooo 200 200 222 e00 o00 MAS 0 12KW eecjecoloce LI MAS 0 12KW ET2008 eee 222 222 g ooo 222222 Boojooo PROFIBUS ezeleee BE essisss a POM Gg Bessy ete ee LOE A ror i to H SORTIES 3 o A E 158 CE PRODUCTS 2 YEARS GUARANTEE TRAINING SYSTEMS amp MODELS Fieldbus study for ETHERNET SCHNEIDER Components EDUCATIONAL OBJECTIVES Studying of Fieldbus communication between different automatism components Studying of the ethernet wiring and IP network creation Settings of Ethernet components Programming of the set TEACHING RESOURCES STUDENT amp TEACHER VIDEO Features of the basement e Base on wheels e Dim Lx xH 750 x 670 x 1950mm e Weight 65kg Practical works e Creating an company IP Ethernet network with multiple PCs e Programming a PLC with a built in or remote Ethernet bus on a TCP IP interface e Programming a HMI interface touch screen with built in Ethernet bus e Programming of a speed converter from the So Move software e Interconnecting and settings of components for a global operation e Using the PLC programmi
20. gate opening and closing push button the gear motor s the light the 24V power supply for the cells and the mains power supply for the 4 photoelectric cells e 1 fault simulator unit enables the user to create a malfunction in the photoelectric cells e 1 set of keys for unlocking the door mechanically 170 CSERODUCT ZZ TEAR CUARAMNIEE TRAINING SYSTEMS amp MODELS Pneumatic handling line a gt ae ee eo E 3 T e 7 i bs i L1 f i E i p 3z na a ar i a LN iE i me e r A Map me a e o aa a x f a r tur 7 38 ee eS a a i T EDUCATIONAL OBJECTIVES Introduction to pneumatic components Programming approach by PLC Monitoring of the system in manual or automatic mode USER S MANUAL amp THEORETICAL COURSES The model is delivered ready for use the electric part is completely wired and alll the pneumatic connections made The quick fit joints allow dismounting reas sembly of pneumatic interconnections with 4mm tubes of various colors A manual gives details of the operation of all the electro pneumatic components used and their adjustment Several cycles are described including one complete with its grafcet MANUAL CONTROL BOX SUPPLIED This box contains e 9 push buttons corresponding to each actuator e 11 indicator lights which give information about the state of the sensors It allows very slow observation of pneuma
21. ronan auton o a Number of outputs LOAN OF Nothing outputs 10 All or Nothing outputs 26 All or Nothing outputs ZA max on resistive load 2A max 2A max Analog 2 inputs 0 1 0VDC o 2 inputs PT100 2 analog inputs 0 10V 1 output 0 10VDC or 4 20mA 1 output 0 10VDC or 4 20MA 230VAC 50 60Hz by means of socket unit switch Etnermet R49 3 mircable 6 detailed practical works Ethenge R45 34m cable PLC configuration use and USB cable PE PLE programming Supplied with Integrated touchscreen units Re toucpox e Resolution S207 7 Oi pixels e a cant Supplied with E E a Ethernet RJ45 3 m cable User s manual with tutorials 172 CSERODUCT eZ EA CUARANIEE TRAINING SYSTEMS amp MODELS SOFTWARE OPTIONS For PLC AUTO 238 For PLC Ery AUTO 238A MAT BOX For PLC AUTO 221 For Touchscreen AUTO PRO AUTO 221 A C TOUCH BOX Ses AUTO PROA aa E O enma ref LOG STEP ref UNITY SMALL ref SOMACHINE Very intuitive it proposes an online help and Very intuitive it allows a multitasking Effective and open professional software tutorials allowing the user to start quickly programming It can convert easily your solution wich includes Vijeodesigner with the different programming screen programs made under PL7 Include the programming of controlers and HMI interface Human Machine Interface Brand SCHNEIDER MODICOM M340 M238 Number of Inputs 16 isolated inputs 24Vcc 14 inputs 24V Number of outputs 16 outputs 2A max
22. selected the most commonly used KNX modules in the intelligent home domain These modules are easy to install on the aluminium wheeled frame The KNX devices are configured using the ETS Lite tool 20 participants max supplied with the model Comprises e 1 Aluminium wheeled frame taking 18 modules e 1 Power supply console 230VAC on 4mm terminals protection by RC circuit breaker 30mA emergency stop 2 2P E outlets with indicator light e 1 Rack for leads 20 fingers e 1 30V power supply module for the bus e 1 USB interface module for programming from a PC e 2 4 key pushbutton modules with indicator lights 1 per brand e 1 2 key pushbutton module with indicator lights e 1 universal pushbutton interface module e 1 Presence detector module e 1 4 output switch actuator module e 1 2 output switch actuator module e 1 2 output control actuator module e 1 1 output control actuator module e 1 2 output roller blind actuator module e 1 Module with printing and signalling for two roller blinds e 1 Module with printing and signalling for opening closing gate and garage e 4 Modules for bulkhead lights 60W 230VAC cCSERODUCT ZZ EAR CUA NEE 153 TRAINING PANELS Training panels simple or communicating version ACCESS CONTROL SYSTEM BY SWIPE CARDS amp ENTRY SYSTEM EQUIPMENT educational reinforced electrical cabinet and modular equipment 230V AC power supply Protected by circuit breakers including on
23. supplied The main cabinet components e 1 Schneider PLC e 1 2 2kW speed controller e 1 analogue card controls the 4 20mA or 0 10V speed controller signal e 1 Ethernet card is used to connect the entire system to an IP computing network such as for example the establishment s network to monitor operations from a remote computing room e Controls on the front of the door General Start Stop button Emergency stop CO2 level potentiometer Auto Manual Fan Start Stop button Potentiometer for the fan air flow Warning buzzer if excessive CO2 level RJA5 connector for the PC link Electrical protective devices for users and equipment Monitoring functions on the PC screen Display on digital displays and by curves e CO2 level and air flow in the tunnel e number of open or closed traffic lanes e presence of a fire in the tunnel e controls access to each traffic lane e regulates the fan air flow e triggers the fire alarm e select the Auto or Manual operating mode CGRRO DUCIS I EARI C UVARANIEPE 177 PROGRAMMING SYSTEM Programming systems with USB connection TRAFFIC LIGHTS WITH PLC This model is a room lighting unit comprising an electrical cabinet and a console fitted with low voltage spotlights Using a TCP IP PLC and monitoring software it is possible to control the model and view its operation on a computer OPERATING PART ELECTRICAL CABINET LIGHTING CONSOLE e 1 32A rated 30mA residual curren
24. the model e A Start cycle button a Stop cycle button e a reset button e a general emergency button stopping the electric and pneumatic supplies e The connector which the user connects to the PLC or to the manual control box USER S PROTECTION e A transparent color door is a barrier between the pneumatic jacks and the user s hand The opening turns off the air pressure PLC only for PNEU99 version e 14 inputs 10 outputs RELAYS e 2 languages Grafcet instructions contact language e Programming from a PC using a software included Delivered with a complete and functional program OTHER CHARACTERISTICS The conveyor belt is either controlled by the automatic system and the end of belt detection switch or by being forced into operation An electromagnet illustrates picking up by a magnetic field PNEU is connected to the air network by splined terminal placed on the valve block of stop regulator filter distribution output by quick coupling PNEU is delivered on a 1000 x 750mm chassis with lateral fixing brackets on a table OPTION COMPRESSOR ref PRESS 35 CSERODUCT T2 EA CUA NIE 171 PLC UNITS Integrated PLC units i r j r T T T P _ _ __ _ i ap i e r f f 1 ox r 4 7 SOCSSCCCCCCRCR00 P oy 000000080000006 i a EET E vw BCE y AUTO PRO A Saye Ge Rice Sata e0eeo 200000 a a y i 7 i m a AUTO 238 A MAT BOX Ree
25. tutorial and instructions for use are supplied voltages and currents in the halogen lamps e Power supply 230V 50Hz voltages and currents in the filter components e Cabinet 820 x 400mm Height 930mm e Switches for activating or deactivating the filter components e Base with wheels with laminated bench top 1200 x 750 x 970mm e An Automatic Manual mode switch e Overall dimensions 1200 x 750mm Height 1900mm Weight 128kg e A lighting potentiometer CSERODUCT T2 EA CUARAMNIEE 193 MOTOR SYSTEMS Fault finding in motor View of the teacher side door closed and open wv View of the student side door closed Faults can be looked for inside the student unit and in the motor terminal EDUCATIONAL OBJECTIVES Simulating common failures encountered with a cage induction motor with brake damage winding cut shorted to ground Diagnosis by performing measurements and safety tests TEACHING RESSOURCES PRACTICAL WORKS The user s manual has been made by teachers Practical works e Cut Winding e Winding in short circuit a allowing the quick implementation of the product e Winding to ground and the creation of practical work in the spirit of Damaged winding fault finding in the industry e Cut brake control system ref MOTODIAG This complete kit on casters comprising two back to back units and an asynchronous squirrel cage motor and a parking brake can be u
26. via ASMAT interface R f M221 MAX see page 172 CHOICE N 2 AUTOMASC is delivered in a plastic box including e a 30 inputs 26 outputs PLC dry contacts e a USB connection interface with the PC e supplies for the PLC outputs e All cables to the lift mains cable It is connected to the lift rear connectors with 2 flat cables one for inputs the other one for outputs PROGRAMMING User can program AUTOMASC with 2 languages Instructions list or contact language You can program it from PC using the software included Delivered with a program designed for complete functioning of the lift OTHER FEATURES The front panel is transparent to see many LED showing the PLC state AUTOMASC is supplied with a demo program which can be modified or completed The technical leaflet indicates the corresponding between the lift inputs and outputs and the ones of the PLC allowing the development of a complete program Mains 230 240V 50Hz 50VA Dimensions 250 x 180 x 175 mm Weight 2 7kg ref AUTOMASC TRAINING SYSTEMS Motorized gates ref PO PB2 e Double casement e Current consumed 0 8A e Max power 200W e Speed reduction ratio 1 296 EDUCATIONAL OBJECTIVES ref PO PC1 e Sliding e Current consumed 1 5A e Max power 290W e Speed reduction ratio 1 30 Understanding putting into service getting started and setting of a automatic or semi automatic portal Interconnecting of th
27. wave oscillating circuit Colpitts Crystal Square generator with fixed variable frequency flip flop timers divider by Z Bistable Intermittent oscillating circuit ref ANALOG9 Schmitt s trigger circuit Sawtooth wave oscillating circuit linear ramp generator Regulated voltage cur rent circuit with zener diode transistor Regulated adjustable voltage Current limiting ref ANALOG10 Regulated voltage circuit with IC Constant current circuit Amplitude modulation circuit AM ref ANALOG11 Frequency modulation circuit FM Transistor differential amplification Characteristics of OP amplifiers input output impe dance bandwidth slew rate offset voltage measure ments for direct and inverse amplifier ref ANALOG12 OP amplifier circuits inverse and non inverse amplifi cation voltage follower Difference amplification Sum amplification clipping circuit constant voltage and current circuit integrator circuit ref ANALOG13 OP amplifier circuits logarithm amplification expo nential amplification circuit peak value detection cir cuit precision clipping circuit voltage regulator circuit sampling hold circuits ref ANALOG14 OP amplifier instrument amplification circuit high pass low pass and band pass amplification circuit ref ANALOG15 Tone controller circuit RIAA amplifier circuit Single power bias amplification circuit Positive feedback OP amplifier comparator Sch
28. 2 ee es ee Le i i prsaesnosnanaa Aa SINAMICS _ Aaa TIT E ar ee ee ee O ae PJ Th ref MAQ NET 0 MAQ NET ref MAQ NET N ref MAO NETN without table table SOFTWARE OPTION LOG STEP is highly intuitive On line help and the practi cal assignments let students learn quickly with the different programming screens Single workstation licence Com patible with Windows XP Home Pro 7 Home Pro 32bits Recommended PC configuration Dual Core Processor 2Ghz or equivalent RAM 2GB and screen resolution 1280x1024 For programming the PLC and the touchscreen HMI Programming of the PIF function ref LOG STEP EDUCATIONAL OBJECTIVES Studying of Fieldbus communication between different automatism components Studying of Profinet and Profibus wiring Settings of components Profinet and Profibus Programming of the set TEACHING RESOURCES STUDENT amp TEACHER VIDEO Features of the basement e Base on wheels e Dim Lx x H 750 x 670 x 1950mm e Weight 64kg Composition of the model WAM Power supply from three phase mains 3 x 400V N E e power supply unit with user and appliance protection 30mA distributes voltage 24VAC to the speed controller for the PLC HMI offset I O interfaces and AOOVAC 3p E e machine box with 3 PB 3 switches 7 indicator lamps and 3 PB and 3 switches for simulating sensors e 2 machine boxes each with 4 indicator lamps and 2
29. 75 PROGRAMMING SYSTEM Managing of hypermarket lighting by supervision Yep Front view ref MAQ LIGHT Large floor area buildings like supermarkets require a lot of lighting The control of this lighting is a real economic and ecological issue which requires thinking about the concept of zoning and presence MAQ LIGHT offers the study of this need through controllers PLC and supervision controlled by 2 touch screens The presentation with two sided vertical panels on a wheeled frame provides an ergonomic view of the zones to be controlled Comprises e 1 unit with magneto thermal RC protection devices amp emergency stop e 3 SCHNEIDER Ethernet PLCs e 1 Ethernet colour touch screen HMISST 3 5 e 1 Ethernet colour touch screen HMISST 5 7 e presence detector e 1 Day Night simulation unit with potentiometer e 1 engraved face defining the 3 lighting zones Face equipped with 16 indicator lights simulating the light points e 3 control units with 7 pushbuttons and 7 indicator lights e Ethernet RJ45 switch e 6 Ethernet leads 1 5 metres anh TTT bitin a Sia ia _ wF E _ a e EDUCATIONAL OBJECTIVES Study and putting into service of a lighting management system for hypermarket by supervision Studying the configuration of an Ethernet type computer network Studying the programming of a PLC in contact language Studying the programming of an HMI Human Machin
30. ANTEE TRAINING SYSTEMS amp MODELS study of the role of the earth amp a differential circuit breaker ref SELDIF The front synoptic shows e the public network with its medium voltage low voltage transformer substation and the neutral to earth connection in this substation e the transmission line from the transformer substation to the dwelling e the domestic installation with the residual current circuit breaker 30mA the local earth and a washing machine The TT neutral system is the same as that of a domestic installation e A person in the right hand part has an LED for a heart If a dangerous leakage current flows here the LED comes on e A two pole industrial residual current circuit breaker 30mA is located in the centre of the synoptic e Two jumpers enable the washing machine to be fully isolated and current measurements to be taken e An ON pushbutton starts the washing machine and a green LED comes on symbolizing rotation of the machine Safety terminals Amm located on the front let the student measure the fault currents and insert different resistive modules These modules simulate two earth resistance values and two leakage current values One module with variable resistance enables the differential s tripping current to be measured To prevent any risk of electrocution to the student the model operates at extra low voltage using an isolating transformer to standard NFC61 558 CEPRODUC T Z2 EAR GU
31. ANUAL amp THEORETICAL COURSES Set of components for the study of a 4 20mA temperature regulation loop with a PT100 temperature sensor and a dimmer switch all controlled by PID regulator Temperature probe PT100 These solutions of regulation are delivered with all the necessary safety leads a user s manual for each component and also wiring diagrams PID REGULATION LOOP ref REGULIDE standard model ref REGUL G communicating model MAIN COMPONENT STANDARD VERSION MAIN COMPONENT COMMUNICATING VERSION a AT403 80X NT a COMMUNICATING Entr e sorte PID REGULATOR F a Ref PID G PID REGULATOR A HA 4 20mA See Page 189 R f AT403 BOX giz Voir page 189 Sortie Alarme ZS0WAC DA GY y HEATING UNIT Ei 4 gt ay i Al A DC POWER SUPPLY Ref RH BOX i UN iI Ref CHT V7 tT Ref AD1 24 See page 187 s a C Es see page 55 east i See page 189 PT100 TEMPERATURE PT100 TEMPERATURE SENSOR SCR POWER CONTROL CONVERTER Ref PT100 BOX Ref GRAD BOX Ref TMPT BOX See Page 187 See Page 187 See page 187 CE PRODUCTS 2 YEARS GUARANTEE 185 REGULATION Temperature control by PLC ref REGULAIR EDUCATIONAL OBJECTIVES Studying the analogical regulation loop Studying the role of the frequency converter in a regulation system Understanding the PID configuration by PLC USER S MANUAL PRACTICAL WORK Practical works TUTORIAL 1 STUDY OF T
32. ARA NIEE EDUCATIONAL OBJECTIVES Educating students about the risks of electrocution in the event of direct contact Educating students about the risks concerning the quality of the earth Showing the role of a 30mA residual current circuit breaker in a house TEACHING RESOURCES STUDENT amp TEACHER Theoretical recalls provided e Operation of a magneto thermal circuit breaker rating breaking capacity tripping curve symbols e Operation of a residual current circuit breaker rating tripping time symbols e Physiological effects of the current hazard zones current function times dangerous voltages e Maximum resistance of the earth Practical work supplied No earth and no insulation fault e potential risk Earth lt 1002 and net insulation fault e with person in contact with the metal enclosure of the machine e with no contact Appearance of a fault current greater than 30mA tripping of the differential Demonstration of the short circuit Earth lt 1002 and low insulation fault Appearance of a fault current less than 30mA no tripping of the differential Measurement of the fault current in the person in contact with the machine Earth gt 1002 and low insulation fault Appearance of a fault current less than 30mA no tripping of the differential Measurement of the fault current in the person in contact with the machine Earth gt 1002 and net insulation fault e with person not in contact with the metal
33. C Speaker 8Q 0 25W with driver circuit 0 25W potentiometers 1kQ 10kQ 100kQ 1MQ Breadboard 1680 tie point breadboard on top panel can be easily put into and taken off permutable Dim 400 x 300 x 130 mm Weight 5 8kg EDUCATIONAL OBJECTIVES Studying by different modules of electrical amp electronical circuits commonly encountered TEACHING RESSOURCES PRACTICAL WORKS AMPERES ROLE DONDE i rae ia ae ore 11 EXPERIMENT MODULES Designed with a 215 x 165 x 30mm solid body plastic housing with electrical wiring printed on the front panel An 8 bit DIP switch located on the right top corner allows the user to simulate faults Each analogue module is delivered with 2 experi ment manuals A E ee RL FEF 41 m STUDENT BOOK supplied with each module A theoretic part definitions terminology characteristics curves schemas theoretical sche mas and wiring diagrams with link slots The functioning is explained in details An experimental part to guide step by step the student to do practical works choice of measurement appliances settings measurement to do blank tables to be filled curves to be drawn Result commentaries additional practical works INSTRUCTOR BOOK supplied with each module Practical works presentation purposes manipulation interpretation Switches position to simulate troubleshooting Detailed and pedagogical solutions of practical works Calculation shown in extenso
34. EE TRAINING SYSTEMS amp MODELS Power quality control Inside view of the cabinet MEASUREMENT READINGS IN MANUAL MODE WITH A NETWORK ANALYSER PAGE 239 EDUCATIONAL OBJECTIVES Understanding and using of the method of Fourier series decomposition Studying of the power in presence of harmonics Understanding the compensation of the power factor by harmonics correction Studying the functioning of the dephasing dimmer USER S MANUAL PRACTICAL WORKS e Making a power balance in presence of harmonic of currents and voltage e Observing the disturbances caused by a dimmer e Raising the power factor by offsetting a portion of the reactive power and filtering of harmonic of order 3 e Observing network disruptions caused by a dimmer Proposed Practical Works 32 18 Ark H25 09 AM H 3t 156 Hz HZ 50 0 2 148 543 A Thad 4 7 SEC 64CT ST 2H g e Increasing the power factor by canceling the reactive power with an anti resonance circuit e Reading the evolution of the PLC program e Producing a summary document as a record Four 500W halogen lamps on a tripod are powered by a SCR power regulator which creates harmonic pollution and reactive power degrading the power factor A passive filter with an LC circuit is used for e minimising the third order harmonic pollution HZ 50 0 55 719 075 A e measuring the power factor by decreasing the reactive power The 59 9 SEC 64CT SMT e observing the res
35. HE 0 10V CONTROL TUTORIAL 2 STUDY OF THE 4 20mA CONTROL TUTORIAL 3 STUDY OF THE TEMPERATURE REGULATION BY PID SUPPLIED READY FOR OPERATION WITH THE TECHNICAL INSTRUCTIONS THE PROGRAMMING SOFTWARE AND THE PLC PROGRAMS WHICH CORRESPOND TO THE VARIOUS TUTORIALS TO BE UNDERTAKEN ALL OF THE COMPONENTS CAN BE SOLD SEPARATELY PT100 Signal TUTORIAL 3 t ORDER MEASURED t ooo0oo0o0000000000 USB LINK A PLC ooo0oo00000000000 COMPUTER N a 4 20mA CONTROL y __0 10V CONTROL MAINS SUPPLY HOT ON OFF 8 REACHED 0000 0o00 BUTTON ON LAMP ORDER A prioote 4484 E PROBE 0 50 FREQUENCY CONVERTER OO O000 k e oz 0 10V PT100 BOX HEATING UNIT MOTO VENTILATOR VOLTAGE i 4 20MA CONTROL GRADATOR BOX For each tutorial students must e Develop the PLC program e Configure the speed controller tutorial 1 and tutorial 3 e Produce the wiring diagram e Wire the components e Modify and observe the speed settings tutorial 1 temperature settings tutorial 2 and PID settings in order to regulate the temperature around a setting tutorial 3 e Using the PLC measure on the PC the setting and instantaneous tempera
36. I PEE ii i UE ii mp T os 471 ite p m aang IBE Bs d is s medal Re ee ee ie ee H a ES Ao a os oe baina l raa ref MAQ IP ref MAQ IP N Without table SWATCH ETHERNET roy i aigi f Autores NZ f n ETHERNET Maquette MAQ IP Das tes ba hemn Pe ee ei N C PRODUCTS 2 YEARS GUARANTEE EEA SAFETY TRAINING Cabinet for electrical authorization e ae aml ak alee vie acute i J E ui G Ri ty e a ee i k i Above HABILIT24 S version mobile version Below HABILIT24 version fixed Close up on disconnectors busbar sets and panel of safety instructions attached to the cabinet bottom ee i n A The service voltage of 24VDC protected by fuse and circuit breaker makes use of the cabinet completely safe The integrated load comprised of six 60W lamps enables a sufficiently significant current to be generated The cabinet is self contained and requires no connection to the mains 230V when in use A mains cable is nevertheless included for recharging the batteries using an integral charger Available in 2 versions fixed or mobile ref HABILIT24 Fixed version ref HABILIT24 S Mobile version with base on wheels EDUCATIONAL OBJECTIVES Put into application the knowledge rules and methods for certification for authorization to electrical hazards Carry ou
37. LOG2 Transistor amplification circuit common emitter circuit common base common collector Automatic and voltage divider bias point Feedback collector base Switching Switching type transistor circuit Relay control ref ANALOG3 Darlington s circuit Photoelectric control circuit Delay control circuit FET measurement of IDSS IGS Vp MOSFET measurement of IDSS Vp FET and MOSFET amplifiers common source common drain Schemes Automatic and voltage divider bias point ref ANALOG4 Two stage amplificator circuit RC coupled Direct coupled amplification circuit Transformer coupled amplification circuit Push pull amplification circuit with impedance adapter transformer ref ANALOG5 Condenser coupling multi stage amplification circuit OTL amplification circuit OCL amplification circuit IC amplification circuit ref ANALOGG Multistage amplifiers with direct coupling Transistor negative feedback circuit Serial voltage negative feedback circuit Parallel voltage negative feedback circuit Serial current negative feedback circuit Parallel current negative feedback circuit ref ANALOG7 Direct feedback circuits Low frequency sine wave oscillating circuit RC phase shifting and Wien bridge oscillator circuit High frequency sine wave oscillating circuit Hartley oscillator circuit Astable oscillating circuit with fixed or ajustable frequency and output on transformer ref ANALOG8 Sine
38. Moreover the instructor will find technical comple ments which can be distributed to students without any modifications 6S PRODUCTS 2T EAR I CUVARANIEPE TRAINING SYSTEMS amp MODELS DC voltage and current measurement Electronic amp electrical circuit lab Ohm s law Power in DC circuit Series Parallel network and Kirchhoff s law Thevenin s and Norton s theorems Maximum power transfer theorem RC circuit and transient phenomena AC voltage and current measurement RC RL RLC circuits Transformer characteristics Series and parallel resonant circuits LC filter ref ELEC Magnetic devices Magnetic field ref ELEC2 Drawing magnetic curves Magnetic field strength Lentz s and Faraday s laws ref ELEC3 Ampere s rule ref ELEC4 Fleming s rule ref ELEC5 Self induction Mutual induction Magnetic flux detection by sensor and amplifier ref ELEC6 Diode characteristics Rectifier circuit half and full wave Filter circuit LC filters and RC filters in x Zener diode characteris tics LED characteristics Transistor characteristics NPN PNP Vce IB Multimeter functions FET characteristics Triac UJT characteristics ref ELEC7 One stage transistor amplifier AB class Push pull Voltage regulator SCR power dimmer Two stages amplifier Relay characteristics Touch controller switch ref ELEC8 Two stages amplifiers by transformers Coupl
39. OUR Thernigu Fiha Peete Meme Gated Fale a l a i 20 t mis Saah ihih ieliet Maht wia benk parry im 11 if 13 14 15 i6 17 i Tew Tac Pate deg Hawass MT 20 00 mmo 01000 ref LOGINIV This PC interface connected to the DB9 outlet and software are used to record and draw graphs of instantaneous water level and control signal of the pump speed directly on PC The connection to PC is made by USB Additional functions e Numerical display of the two measurements e Cursor function e Compilation of data in a spreadsheet e Zoom function C PRODUCTS 2 YEARS GUARANTEE 181 REGULATION Level control system by means of PLC amp Touchscreen EDUCATIONAL OBJECTIVES Studying putting into service getting started and setting of the system Understanding the setting and the programming by PLC Understanding the PID level regulation probes and sensors TEACHING RESOURCES PRACTICAL WORKS Practical works e Drawing of wiring diagrams e Setting and programming the PLC e Configuration of the PC Ethernet links PLC Touch Screen e Configuration and setting of the touch screen e Setting the 4 20mA water level regulation with the PID of the programmable PLC e Wiring the grid e Understanding the functioning of the level regulation by PID probes and sensors REGULEAU is a level control system relying on a PLC and touchscreen which can be used in three detection modes using e 3 binary float
40. PB and 2 switches for simulating sensors e PLC SIMATIC S7 1200 141 100 Integral Ethernet port e Profibus interface e 1 ETHERNET switch 4 ports RJ45 e 1 HMI colour touchscreen 5 7 with Profinet RJ45 port e 1 interface ET200S 41 40 offset with Profinet coupler e 1 interface ET200S 41 40 offset with Profibus coupler e 1 speed controller SINAMICS G120C 0 55kW with integral graphic terminal e 1 Asynchronous motor 230 400V 0 12kW with fan for viewing rotation 1 set of Profinet Profibus leads e 1 set of Profinet Profibus connectors for mounting e 20 metres of Profinet Profibus cable e Starter software for programming the speed controller e 1 CD includes the instructions for the different components and the practical assi gnments and programming examples for the PLC the speed controller and the HMI HMI Human Machine Interface KTP600 SWITCH KrP600 Dfe 2 o 900 ule e 2229 Ha 3 s 2 Se See texan 0 7 1200 B PROFIBUS a M pROFIBUS T seeleos oce 200S 2eefoo o00 PROFIBUS
41. RS started and setting of the system E T 2 PUMPS Understanding the settings and the program ming of the PLC P e 230 400V 3 phase motor Know more about the monitoring application 3 gt SINGLE PHASE UPON REQUEST bh 4 e Power 750W a e Stainless steel body and RAR S turbine Proposed Practical Works ________ W e Auto start e Setting of the PLC FLOW CONTROL VALVES e IP addressing management e 1 for setting tank pump Loading modification monitoring creation 1 for water tower pump ALL OR NOTHING FLOW SENSOR Schneider mm RE Detects water flowing in the PVC e Dry contact horizontal level pipe of the CHATO circuit An SENSo NO or NC contact at the sensor e max voltage 24V output sends information to a e Max current 3A PLC or a contactor 150L TANK MONITORING ON TOUCHSREEN RER CHATO4ST6 PLC programming software Monitoring software VijeoDesigner 5 7 inch colour touchscreen The monitoring software delivered with the set allows to modify the initial program and to create CCC your own programming Used to drain the tank e q to simulate reservoir f 9 Simulates domestic water e Simulate the river maintenance consumption e Plastic tank with drain plug Connected by hoses to the e Installed on a base so it can tank that simulates the river be moved with the system 1 ES gt ri The sensor shows the flowrate of the water on the display unit when it lea
42. TOR 6 all or nothing outputs 4 static outputs 24V 4 voltage current inputs LOV 7 O 10V 7 0 5V 7 IVZ 25V 2 inputs 4 20mA 0 1 0Vcc 0 20MA Z 4 20MA 20MA output 4 20mMA 7 0 1 0Vcc 2 voltage current outputs 10V 0 20mA 4 20MmA EinemetmoduieiGh Ar nmks45 Ethernet port 1 Modbus port 1 Ethernet port UNITY SMALL in option SoMachine in option 230VAC 50 60HZz by means of socket unit switch 360 x 270 x 170mm 330 x 200 x 80mm RE AUTO PRO AUTO PROA AUTO 238 AUTO 238 A 1 ethernet RJ45 3 m cable 1 ethernet RJ45 3 m cable 1 USB cable eas SPATE oe z STU BOX6 TOUCH BOX amp 6 x ca STU BOX4 CEEROPDUC T TT EAR I CUVA RAINE 173 PLC UNITS Programmable controls system BASIC MODEL MODEL WITH TCP IP ETHERNET MODULE T ider This unit is a programmable interface working as a PLC with orders inputs and We have added to the ZELIO 201 24 opposite a network communication module contacts outputs Its particularity is to integrate a clock which sets controls Its which can be used to connect the ZELIO to the Ethernet using the Modbus TCP programming software is very easy to use Among its various and user friendly protocole functions the function SIMULATION which allows to check the program before using it in real condition Ethernet module features Dimensions of the box 360 x 270 x 170mm e direct connection to the ZELIO e female RJ45 reinforc
43. TRAINING SYSTEMS amp MODELS Training panels PAGES 152 156 Fieldbus PAGES 157 159 Safety training PAGES 160 161 Training systems PAGES 162 171 PLG PAGES 172 175 Programming PAGES 176 179 Regulation PAGES 180 190 Energy PAGES 191 193 Motor system PAGES 194 196 Circuit Lab PAGES 197 203 Test units PAGES 204 206 Sensors PAGES 207 209 TRAINING PANELS Home automation panel with touchscreen and radio components Coupling a receiver transmitter pair through the protection window by pressing a contact Panel delivered wired programmed with instructions of each components FRONT VIEW diagrams and practical works E REAR VIEW ref DOMOPLUS EDUCATIONAL OBJECTIVES Understanding of the housing automation made for the housing renovation BEFORE AFTER Understanding of a real and complete solution for a flat Se heer DOUBLE CIRCUIT SWITCHING Studying the wiring and settings of communicating components POINT LIGHT POINT LIGHT Studying the programming and the DELTA DORE solution e to circuit breaker Proposed Practical Works ee B I e Renovation of different circuits lightings thermal circuit e Programming according different imposed scenarios Radio receiver Features of the basement e Base on large wheels e Dim Lx Ix H 1500 x 750 x 1980mm e Melamine surface 1200 x 1700mm e Weight 128kg Controlled by switch
44. They cannot come into contact with dangerous voltages as these are confined to the electrical cabinet The maximum voltage that can be accessed on the student terminal block is 24V DC The terminal block and the components allow all wiring errors and fault finding exercises The water level and pump delivery curve charts curve charts used to determine the static gain loop gain and critical gain the dead time and the time constant are noted either manually the slow speed of the phenomena means that this procedure is possible or using a PC combined with LOGINIV software option and the associated interface or by using general software The DESNIV model does not need to be connected to the water network In order to prevent any overflow a binary level sensor stops the pump if the water rises up to the top section of the column TRAINING SYSTEMS amp MODELS SUPPLIED WITH A 4 20MA LOOP CALIBRATOR e Programming in of the output span to supply a typical intensity like 4 8 12 16 or 20mA e linear ramps manual ramps auto ramps e Display 5 digits e Carry case user s manual external battery Pack for 6x 1 5V AA batteries e Input for mains adapter DC 1 2V not included e Dimensions 88x168x26mm Weight 330g RESOLUTION ACCURACY 1 uA 0 025 5A 1 uA 0 025 5A 1 uA 0 025 10A ImV 0 05 5mV ImV 0 05 5mV ImV 0 05 10mV LOGINIV INTERFACE amp SOFTWARE OPTION s VISIFOUR Conirale da F
45. Torque wave form for a winding with one notch e Calculation of the resistance of a phase Practical check e For each phase power supply strategy establish the opening and closing sequences of the switches wire the control circuit based on the waveforms of the torques for each phase determine the waveform of the resulting torque and currents determine the optimal polar arc CGRRO DUCI SZ Eke RAINE CIRCUIT LAB k e el a r AF eo SiMe p Sas bees a krent ine _ T me a 7 a lt AMANANAA Electronic circuit lab equipped with a main unit and 11 experiment modules Each module permits to realize several practical work Supplied with leads and user s manual ee MAIN UNIT PSY2101 INCLUDING A fixed DC supplies with output overload protection 5V 5V 12V 12V 300mA on each output Dual DC power supply with output overload protection 3V to 18V 1A continuously adjustable AC power supply with output overload protection 0 9VAC 500mA Signal generator Sine square and triangle 10Hz to 100kHz 4 ranges 100Hz 1 10 100 kHz Output impedance 509 Output voltage 9Vpp with 502 load 18Vpp open loop ref PSY2101 3 1 2 digit digital voltmeter and ammeter Range 2V 200V accuracy 0 3 Range 200pA 2A accuracy 0 5 Analogue voltmeter and ammeter O to 20V DC 0 to 100mA DC 0 to 1A DC O to 15 V AC 0 to 100mA AC 0 to 1A A
46. a visual LED display and a piezoceramic type buzzer with integral micro oscillator ref B3510 L Dim 250 x 150 x 30mm Weight 900g Includes a stepping motor with 2 separate coils the motor driver and the specialised logic test circuit The latter can be accessed either by a PC via a 25 pin parallel port or by a manual control logic system integrated This logic comprises a controled impulse generator by push button for the step by step lead and a variable frequency generator for the continuous working ACCESSORIES SUPPLIED 1 set of leads 2mm 2 x 100cm 4 x 30cm 3 x 15cm 1 lead DB25 SERIE 1 software on CD ref B3510 T Dim 250 x 150 x 30mm Weight 900g 6S PRODUCTS I EARI CUVA RANEE ee PRACTICAL WORKS e Study of the luminous barrier frequency voltage converter Study of the tachometric filter e Study of the loop amplifier and of the controlled switching power supply e Comparison of tachometric voltages and optical encoder converter e Comparison of low rotation frequencies with and without feedback loop Study of the feedback response for different values of loop gain PRACTICAL WORKS e Description of the different components and their usage e Functioning of the amplifiers e Measurement of the detection distance of the inductive sensor e Analysis of the electronic switch controlled by direct or alternating current e Study of a line consisting of an optoelectro bar
47. adder circuit Bit parity generator with XOR gate 10 to 4 bit decoder with TTL IC ref DIGITAL4 A to 2 bit encoder 4 to 2 bit decoder Decoder circuit experiments decoding 7 segment display with BCD code ref DIGITALS5 10 to 4 bit encoder Multiplexer circuit experiments Digitally controlled analog Multiplexer demultiplexer circuits Bi directional transmission with CMOS IC ref DIGITALG Oscillator circuit with basic logic gates with Schmitt trigger Voltage controlled oscillator circuit with 555 trigger Monostable multivibrator and synchronous astable multivibrator ref DIGITAL7 CEEROPDLUC T TEAR I CUVARANIBE 13 EXPERIMENT MODULES Designed with a 215 x 165 x 30mm solid body plastic housing with electrical wiring printed on the front panel An 8 bit DIP switch located on the right top corner allows the user to simulate faults Solution for faults are listed in the experiment manual for user s reference Comprehensive experiment and TRAINING SYSTEMS amp MODELS instructor s manual are supplied with modules and contains theoretical drawings wiring drawings The experiment part has input signals location of test points tables to be filled up comments and exercises ee en m om mo oe Variable duty ratio oscillator RS T D JK flip flop Preset left right shift register circuit Noise elimination circuit ref DIGITAL8 JK flip flop asynchronous synchronou
48. al board which protrudes onto the console enables the user to add an ammeter or a wattmeter in order to measure the current and power SET OF CABLES Set of two 3 metre long cables supplied with TAPIX Wena epee reer eee el deve eee eee eee a ee ee ae A 162 CE PRODUCTS 2 YEARS GUARANTEE TRAINING SYSTEMS amp MODELS MODEL WITH TEST CABINET MODEL WITH TEST CABINET AND MONITORING These versions are identical to TAPIX only the connec H tion console is replaced by a control panel and a test Schyeier am cabinet The setting up of the grid is immediate It s an autonomous system lif 4 Harting connectors connect the grid to the test ca binet end the control panel The right panel of the test HE cabinet is equipped with the buttons and the indicator lights necessary to the startup of the student s grid Some versions as TAPIX ARM GD It s an autonomous system USER S MANUAL SUPERVISION PW REF TAPIX S TAPIX S T6 PLC programming software E 7 Software for touchscreen Software for PC 5 7 inch colour touchscreen MONITORING ON TAPIX SYSTEMS ENABLES THE USER TO DISPLAY ref TAPIX ARM GD e till open information e last customer information ref TAPIX CAB model with wired grid e information request details e Presence of items on the belt FEATURES OF THE POWER CONSOLE The build up of lems on the beli e Console which is used for safe testing and supplies the three phase and 24V power e
49. and standard pushbuttons MAQ SI uses the simulation of lighting commercial spaces to facilitate the teaching process EDUCATIONAL OBJECTIVES Study of a wiring diagram developed in automation Study and operation of a PROFINET computer network Study of the programming of a SIEMENS PLC Study of the programming of an HMI Human Machine Interface TEACHING RESOURCES STUDENT amp TEACHER VIDEO Practical works e Creation of the wiring diagram e Creation of the PROFINET computer network e Creation of the PLC programs in contact language e Creation of the supervision from the HMI Human Machine Interface e Change of IP addressing e Test of the assembly Features of the basement e Base on wheels e Dim Lx x H 750 x 670 x 1950mm e Weight 60kg Composition of the model Power supply from the mains 230VAC Mains lead 3m e 1 unit with magneto thermal protection residual current device 30mA and emergency stop e 1 SIEMENS PROFINET S7 1200 14 inputs 10 outputs PLC with analogue board 4 20mA 0 10V e 1 SIEMENS KTP600 PROFINET touch screen 5 7 inches 256 colours e 1 Day Night simulation unit 4 20mA 0 10V 1 printed face with 16 indicator lights e 1 control unit with 4 pushbuttons and 5 switches e 1 Ethernet RJ45 switch e 6 Ethernet leads 1 5 metres 6S PRODUCTS Z Weeks QuaAlyaiN ce 157 FIELDBUS Fieldbus study for PROFINET amp PROFIBUS SIEMENS Components
50. and automated temperature control All the components are surface mounted to facilitate signal capture CHARACTERISTICS Each of the three analog sensors is connected to an amplifier to suit its voltage impedance and linearity The output levels of the three amplifiers are all calibrated at 10mV C to facilitate comparisons of accuracy e On screen temperature display for the 3 sensors anc bernal nerna e On screen display of the fan and heating control signal Two temperature control systems may be studied all or nothing heating by hysteresis circuit or proportional characteristics heating with a variable gain automatic control loop The heating power circuit is either powered by e Configurable acquisition time transistor controlled direct current or by Triac controlled 15VAC alternating current A digital thermometer e Zoom function provides a continuous readout of heating element temperature e Cursor function x and y axes configurable e Scale notation Max and Min values e Curve and background colours configurable CHARACTERISTICS e Print characteristics after page layout configuration 4157 215V DC powersusply e Acquisition data recovery in spreadsheet form e Equipped with a DB25 male plug to connect to the PC interface DOAN WANE AVAIIAELE E SI ANDINA e Dimensions 330 x 200 x 50mm e Weight 1kg CSERODUCT P2 Foo CUARAMNIEE 207 SENSORS soeed feedback Ea 3510 L Bee eae 4 4 4
51. ce operations USER S MANUAL 6 PRACTICAL WORKS Proposed Practical Works e Temperature stabilization by simple fan air conditioner alone by ventilation and air conditioner e Sudden internal heat e External temperature too low winter e Condensation problems e Incorrect design of the air conditioner preventing temperature stabilization e Adjustment of the temperature set point CLIMABOX is an air conditioned industrial electric board often used in industry whenelectronic components need a steady temperature Delivered with wiring diagrams and practical works MAIN COMPONENTS e A complete air conditioning system e An extractor fan e Many heating resistors e Two counters start and time e Four digital thermometers e One alarm buzzer FEATURES OF THE BOARD e 230V 50Hz single phase power supply e Dim Lx W x H 550 x 450 x 650 mm Weight 45kg C PRODUCTS 2 YEARS GUARANTEE ref MAQCOS l EDUCATIONAL OBJECTIVES Studying the power factor amp Demonstrating the interest of power factor corrector for the cost of the power kWh USER S MANUAL 3 PRACTICAL WORKS Proposed Practical Works _ e studying of an industrial lighting installation from fluorescent tubes Current of branches power of the transport line with and without power factor correction Active and reactive power in the branches Fresnel diagrams e Study of the pure inductance of a plant in working in o
52. cess and the correction component e Determining the static features of the procedure with a view to calculating the following adjustments integration constant dead time e Implementing various empirical methods for setting PID correctors e Testing the performance of the loop in servo control mode and in regulation mode e Displaying on a flatbed plotter or PC or by manual measuring the responses of the PID adjusters by requesting the measurement input by position or speed level Implementing and verifying a level measurement for a dry column or a wet column DESIGN The DESNIV model uses only industrial components e A PID regulator 4 20mA standard on the measuring input and on the output e An industrial three phase pump with a bronze body e A differential pressure level sensor e An industrial frequency variator The column is large in size as is the volume of water it contains Therefore it has high inertia This means that the physical phenomena are very similar to those for high capacity tanks used by the pharmaceutical and oil industries Pressure differences due to the significant height of the water column can be used to adjust the water level to the nearest 5mm The inputs and outputs for the following are grouped together on a terminal block which is separate from the electrical cabinet sensor regulator variable speed drive and 24V DC power supply Students wire up the control and measuring loops on this terminal block
53. ctrical cabinet and 2 toll lane indication signs Using a TCP IP PLC and monitoring software it is possible to control the model and view its operation on a computer opening closure of lanes mana gement of banker s card or telepayment electronic road pricing ERP payments manual or automatic function with time stamp on the PLC etc ELECTRICAL CABINET e 1 32A rated 30mA residual current four pole circuit breaker e 1 bipolar circuit breaker for protecting the PLC and sign e 1 set of junction boxes OPERATING PART EACH CONSISTING OF e 4 24V lamps Open Closed Banker s card Telepayment e 2 m of multiwire cable for connecting to the electrical cabinet PLC PC connection by USB e with 10 relay outputs and 14 inputs supplied with 1 TCP IP interface for Ethernet connection 2 1 5m multiwire cables for interconnection with the model programming software in English French in ladder language e Dimensions 170 x 130 x 130 mm 230 240VAC MONITORING e Multilingual programming software for managing the toll indication cabinet from a PC e Offers the basic features of a graphical tool acquisition and display of PLC variables monitoring and control of the toll lane lane open lane closed payment by BC or telepayment e The software s graphics editor supports many applications The user can modify the preloaded demo program or create a new one FEATURES OF THE ASSEMBLY e Powered by a 230V mains cable e M
54. cy lighting unit BAES with information transferred to the PC e 1 addressable LED EVACUATION and self contained emergency lighting unit BAES with information transferred to the PC e 1 addressable BI FUNCTIONAL LED and self contained emergency lighting unit BAES with information transferred to the PC e 1 modular BTI URAVISION interface for the ETHERNET connection between the self contained emergency lighting unit network and the computer e 1 manual unit shutdown control e 1 spotlight connected to the mains showing its presence 156 C PRODUCTS 2 YEARS GUARANTEE FIELDBUS TRAINING SYSTEMS amp MODELS study model for the PROFINET system with supervision SIEMENS i gee dl T rey 7 A L W uT E D a l a POITE EEEE EEEE POTEEUUTUTENE CE TA ba a Fj ae a e g ers _ PROFINET is an open communication standard for industrial automation Developed by SIEMENS PHOENIX Contact MOLEX and other constructors it provides automation solutions for processes production and movement control Through its opening and the use of standard communica SS 7 g tions media Ethernet PROFINET enables the use of all brand of equipment MAQ SI is a study system equipped with SIEMENS components and designed for understanding the PROFINET system with programmable controller touch screen
55. ding the different types of signals like thermocouple thermoresistance thermistance 0 10V and 4 20mA linear outputs e Bar graph image of the power output e 4 20mA input on safety sockets 4mm e 4 20mA output on safety sockets 4mm e 250V 5A relay output on safety sockets 4mm e Alarms output high amp low on safety sockets e Internal timer e Supply 240VAC 50Hz e Dimensions 145 x 185 x 100mm DC POWER SUPPLY ref AD1 24 24V 2 2A DC Supply Output on safety sockets Amm Protection overload and short circuit by electronic limitation 6S PRODUCTS Z WeANxs QuaAlyAN cle e Configurable output in O 10V and 4 20mA on safety sockets e All or nothing alarm relay output on safety sockets e The PID unit is fully configurable from the keys on the front panel or from the software e Power supply 230VAC 50Hz power cord e Programming software connection lead to PC delivered with the unit e Dims 150 x 200 x 100 mm ee pI fir PETC RTE LD REGULATION System for heat regulation by P I D AOE TUN FOUR DESP REGULATION THERMEN iA EDUCATIONAL OBJECTIVES Understanding of the regulation principles by PID from theory to practice Wiring calibration loop measuring statement of curves USER S MANUAL 15 PRACTICAL WORKS Practical works e Wiring of a measuring loop according the standard 4 20mA with Pt100 probe and transmitter e Calibration of the converter Pt100 4 20mA with the help
56. down except the ground floor with indicator lamp 1 lamp to indicate the presence of the lift 1 photodetector to indicate the presence of the lift CONTROLS INSIDE 4 buttons for each floor 1 stop button THE LIFT 1 switch to simulate a blocked door 4 lights for each floor 1 light inside the lift simulating the lighting UNIT SUPPLIES the motors the LED internal logic to the unit POWER TO OTHERS Dims 780 x 480 x 440mm Weight 15kg Supply 230V 50Hz SPECIFICATIONS The unit is available in two driving logic values 24V or 5V INTERFACES FOR DIDACTIC LIFT CHOOSE ONE OF THEM INTE RFACE WITH BUILT N PLC C PRODUCTS 2 YEARS GUARANTEE 169 CHOICE N 1 ASMAT is an interface allowing a quick connection to the ASC89 lift from a PLC To help in quickly identifying the functions of the connectors small symbol and piece of text next to each connector allowing immediate understanding of its function The operating sense Lift PLC or PLC Lift It is clearly indicated by vertical arrows Metal box 22 x 272 x 32mm Weight 250g CONNECTION CONNECTION ASMAT LIFT ASMAT PLC Two flat cables with One The front face of the board has two columns of 4mm plugs which are used to connector for the inputs and connect to the PLC with normal leads The plugs on the left are for the the other for the outputs inputs to the PLC on the right for the outputs ref ASMAT PLC which can control the 24V lift
57. e 30mA e 1 access control module 6 swipe cards and 1 entry system e 1 PLC Schneider Supplied with programming software and communicating software Vijeo Designer ref GES 2 COM EDUCATIONAL OBJECTIVES Understanding and setting of an access control system by swipe cards amp entry system Programming and setting of the Schneider PLC for the COM version Understanding and use of the supervision on PC for the COM version Understanding of an IP network for the COM version USER S MANUAL PRACTICAL WORKS ENTRY ACCESS amp VIDEO ACCESS CONTROL SYSTEM EQUIPMENT e 1 educational reinforced electrical cabinet and modular equipment 230V AC power supply Protected by circuit breakers including one 30mA e 1 door opening onto the street with electric door opener e 1 street video unit comprising a camera a loudspeaker a 4 button caller keypad one for each area e 1 building videophone with a screen that is linked to the camera e 3 building entry phones The videophone and entry phones have a button which controls the electric door opener e 1 4 channel distributor for interconnec ting the videophone and entry phone e 1 PLC Schneider Supplied with programming software and communicating software Vijeo Designer ref GES 5 COM EDUCATIONAL OBJECTIVES Understanding and setting of an access control system by video and intercom Programming and setting of the
58. e Interface Studying the coexistence of several PLCs and HMIs TEACHING RESOURCES STUDENT amp TEACHER Practical works e Creation of the architectural diagram of the electrical installation e Creation of the computer Ethernet e Creation of PLC programs in contact language e Creation of the supervision from the two touch screens e Change of IP addressing e Testing the assembly Features of the unit e Power supply 230VAC by 3 metre mains cord e Dimensions 750 x 670 x h 1950mm e Weight 64 kg 176 C PRODUCTS 2 YEARS GUARANTEE TRAINING SYSTEMS amp MODELS Ventilation control and Tunnel access i al _ eo J m i o s o j ad i i m 4 4 3 Features of the unit e Wheeled frame 750x670mm J e Total height 1870mm e Powered by a 400V three phase hypra socket e 1000VA Fan 96m3 min maximum flow rate 400V 3 phase 400mm SIMULATEUR DE GESTI ON DE VENT ET D ACC S DUM E VENTILATION TUNNEL ROUTIER E ie T 1 W i r pue be pan a e O a www langlois frane iil my or al Wo r ay io ms j p p a i ce Oe ee Ml ads ie T ee po Be De i i Janaa P PY eee ee os Ue EFT OA eg a r Lie ed ie Bii Cii im Lows m imm Bai Monitoring software arane program Monitoring from a PC Se SS program EDUCATIONAL OBJECTIVES Studyin
59. e different components in jumper wires mode Tutorials are supplied with automatic functions e Wiring of all of the components e Adjusting the various operating settings e Measuring the properties of gear motors and comparing these values with the ones for the rating plate e Looking for one or more faults Features common to both gates e Emergency stop circuit breaker e 230V AC mains power supply e Power supply to photoelectric cells 24V AC internal power supply e Fault simulator unit with 4 circuit breakers causing a fault on each cell e Life time pre lubrication using grease e Dimension of the unit 1400 x 800 x 1700mm Weight 90kg e Sold with all connection diagrams and all the various settings to be entered for the smooth operation of the gates USER S MANUAL 4 PRACTICAL WORKS Components involved in the automatic operations common to both gates e 1 frame on wheels with brake e or 2 gear motors depending on the selected automatic operation model e 2 pairs of photoelectric cells to secure the opening and closing of the gate e 1 unit fitted with an electronic card controls the operation of all of the different settings such as closure time delay activating the remote control etc e 1 gate opening and closing remote control e gate operation indicator light e 3 consoles consisting of 4mm safety terminals for the 230V and 2mm for the extra low voltage containing the wiring for the key operated
60. e river e 2 transparent tank 60L simulate the settling basin Fitted with 3 water level sensor all or nothing e 2 motorised pumps draws the water river to the basin basin to the water tower e 1 tap drains the water tower e 2 All or nothing flow sensors e 1 valve drains the settling basin e 2 valves at the motorised pump output to adjust the flowrate of the water e 2 emergency overflows e 750 x 1500mm base on wheels enables you to move the system e test cabinet not wired e 1 electric console with control and protection Understanding putting into service getting started amp setting of the system Wiring of different components and connection USER S MANUAL PW Proposed Practical Works e Wiring of electrical components according the different operating modes e Troubleshooting and maintenance DOOR OF THE CABINET OPENED DOOR CLOSED J j 5 J 4 J Ca de FEehes f Bjal sal saiia k a a a e et eee hith srk al Rept Rem ma Mame ee eed bid Me bee I is a iaai lp lon imp a i TECHNICAL FEATURES OF THE CABINET 800 x 600 x 250mm steel cabinet supplied with a grid efile Plate on door with unwired control lamps and actuators Free spaces for the addition of DIAM 22 control components Rapid connection and hanging of the grid not exceeding 750 x 750mm Door safety contact Fixed connectors on grid to be wired by students Male Harting connectors to level sensors to motorised pumps t
61. ecessary colour drawings are used to illustrate comments Angular diagrams timing dia grams and schematic diagrams are used to illustrate step by step the operation and or stages of implementation In addition the following is required for all tutorials e a 30V DC 2A power supply e an oscilloscope with a memory function e a dynamometer a gaussmeter not essential used for checking the current of the field e enamelled wire for winding on the rotor s supplied Automatically controlled synchronous machine TUTORIALS ALL LEVELS OF TRAINING Because the motor is open students can see the air gap the orientation of the magnetic field the di rection of the current the direction of rotation the active winding part and the yoke MICROMAG can be used as a motor or a generator By manually rotating the rotor the machine will operate as a generator Students read out from the oscilloscope the EMF on the two phase terminals This voltage indicates indirectly the torque ripple when the machine is operating as a motor EXAMPLE 1 For each of the three phases students produce a static torque diagram or EMF diagrams for each phase based on the rotor s angular position Students check the values experimentally by measuring torques using a dynamometer and the EMFs shown on the oscilloscope They plot torques in a graph and check them experimentally EMFs respectively when the two phases are connected in anti series or th
62. ed cable Sum up of functions and possibilities of the unit and its software e a communication display LED LK ACT 10 100 e 12 inputs 24V DC 6 can be wired in analog inputs O 10V e a STATUS display LED STS e 8 dry contacts outputs e a display indicating state and local programming e 6 keys for local programming SOFTWARE SUPPLIED WITH ZELIO 201 24 AND ZELIO NET Zelio Soft 2 Logiciel de programmabon Programming sofware The multilanguage software also has Help function for user e 3 programming languages Besides its help function always available as a Search Menu the software has e a good viewing of clock settings a demo video functioning like a VCR Short films show the main steps for e a free keyboarding of associated comments for the follow up of steps programming the system e a simplified communication between the unit and the PC serial connection e a direct display of the text on the unit display e a visualization of outputs state e an input output computer simulation by a simple click on the mouse 174 C PRODUCTS 2 YEARS GUARANTEE TRAINING SYSTEMS amp MODELS simulator for checking controller PLC programming l i Checking a PLC program requires the connection of an operative part PUP PLC groups together a set of actuators power supplies and components required for checking programs lts complete composition provides great comfort for this check seests 5 Fe Se E s 3 a2 0 n 0 3
63. enclosure of the ma chine measurement of the fault current e with person in contact with the enclosure measurement of the fault current greater than 30mA no tripping of the differential LED symbolizing the heart coming on Others characteristics e Power supply 230VAC 50Hz e Dimensions 390 x 270 x 100mm e Weight 2 3kg e Supplied with 5 resistive modules coupling jumpers amp leads TRAINING SYSTEMS supermarket checkout simulator OPERATIVE PART ONLY EDUCATIONAL OBJECTIVES Understanding putting into service getting started and setting of the system Making different wirings and functioning tests Illustration and visualization of the result of a PLC program USER S MANUAL PW Proposed Practical Works e Studying and locating of the different components e Wiring of cells light signal tower and gearmotor e Making different wirings corresponding to various operating scenarios of the system Features of the basement e Frame on wheels e Dimensions 1600 x 650 x 1150mm Hight without indicator light e Weight 60kg B Photo electrics CONVEYOR BELT cells Cashier unit TAPIX is a conveyor belt for a cash register with the same features as the ones you would find in a supermarket lt comprises a conveyor belt driven by a gear motor a control unit used by the cashier an indicator light showing the status of the cash till and start and end of belt sensors The TAPIX system will
64. etal industrial cabinet with a glazed door Dimensions 400 x 300 x 200 mm e Indication sign 420 x 80 x 70 mm e The unit is supplied already wired with an example of monitoring and all the linking cables which are required for its proper operation SAMSUNG This model simulates a drinking water pumping station Using a TCP IP PLC and monitoring software it is possible to control the model and view its operation on a computer OPERATING PART e 3 push buttons for On Cycle Start Cycle Stop e 6 switches representing the water level sensors e 4 lamps representing the operation of the two pumps PLC PC connection by USB e with 7 relay outputs and 9 inputs supplied with a TCP IP interface for the Ethernet connection a 1 5m M F DB25 cable for interconnection with the model programming software in English French in ladder language e Dimensions 170 x 130 x 130 mm 230 240V AC MONITORING e Multilingual software for controlling the lights using a PC e Offers the basic features of a graphical tool acquisition and display of PLC variables monitoring and control of the station operation start up and shutdown of the pumps and maintenance operations etc e The software s graphics editor supports many applications The user can modify the preloaded demo program or create a new one FEATURES OF THE ASSEMBLY e Dimensions 330 x 200 x 80mm e The assembly is supplied already wired with a monitoring examp
65. evel measurement by hydrostatic pressure of wet column Adjust the level transmitter Wiring putting into service amp adjustment of components transmitter regulator Make current measurements as in industry without opening loops with the help of a multimeter Taking in hand the setting software of the frequency converter TEACHING RESOURCES 19 PRACTICAL WORKS PRACTICAL WORKS ON THE MEASURING CIRCUIT e Wiring the measuring loop which comprises the 4 20mA output differential pressure transmitter a 24V DC power supply and the PID e Calibrating the level transmitter Dry column method e Calibrating the level transmitter Wet column method e Producing a calibration sheet for the transmitter and a calibration curve e Calculating the scale range of the transmitter e Measuring the current in the loop without opening it e Using a calibrator for measuring the transmitter current or generating a 4 20mA current on the PID input PRACTICAL W ORKS OF REGULATION e Producing a regulation loop diagram with a view to wiring the correction component and the measuring circuit e Producing an operating diagram through the identification of various components namely the regulator the correction component and the process e Identifying the quantities at play namely the adjusted quantity controlled variable correcting variable and disturbances e Determining the direction of the regulator depending on the direction of the pro
66. g putting into service getting started and setting of the system Understand the setting and the programming by PLC Understanding and use of a supervision Practical approach of analog inputs USER S MANUAL TUTORIALS MONITORING Proposed Practical Works e PLC programming e Loading modification creation of a supervision program e Ethernet network configuration e Analysis of the regulation TA11 is a study system used to regulate the CO2 level in a motorway tunnel It consists of a fan for air renewal and an electrical cabinet grou ping the regulation system components The cabinet and fan are placed on a wheeled frame and connected by a 5m cable Complete unit supplied ready for operation with monitoring The PLC is supplied as well as the monitoring program and wiring diagrams Are also supplied The Teachers Students tutorials on PLC programming monitoring the Ethernet network analogue regulation Operation On the cabinet s door a potentiometer simulates the CO2 level in the tunnel Depending on the CO2 level the PLC controls the fan s rotation speed and plans the access to the 4 traffic lanes represented by 8 indicator lights positioned above the cabinet A stand alone fire sensor indicates there is a fire in the tunnel An electronic buzzer warns that the CO2 level is too high An anemometer fixed in the fan s air flow controls the rotation This regulation system is PC monitored via the Schneider software
67. hase after another they firstly check the connection Next they connect the switches of the switching system with the three phases of the stator By overriding the rotor switch drive system students check that its rotation is driving the rotor in synchronism Finally by resetting the switch drive by the rotor students test the machine in automatically controlled operating mode Students read out from the os cilloscope the currents in two successive phases and their conduction diagram EXAMPLE 5 The aim of the tutorials is to draw students attention to the various power supply strategies with a view to establishing a rotating field To this end they have a document to complete which shows the successive angular positions of the switch and the rotor the status of the switches the current in the windings and the angular diagrams for each phase They must determine the shape of the torque for each phase as well as the resulting torque TUTORIALS UNIVERSITY amp ENGINEERING SCHOOL e Principle of axial motor e Main pa and Ja parameters of a permanent magnet e Recoil line e Ampere turns of a coil equivalent to a magnet e Hypotheses about the field and materials e Magneto static laws used e Calculation of field B and comparison with the measurement e Motor torque calculation Generator EMF calculation e Relationship between EMF and torque e Calculation of a number of turns for a given torque e EMF waveform for a winding with one notch e
68. ic graph e A switch on the front of the unit is used for activating or deactivating the H3 and H5 filters e Jumpers and double channel terminals are used for electrical measurements current voltage and power not only on the network side but also on the receiver side and in each filter FEATURES e Operation on 230V single phase network or 230V 400V three phase network e Fitted with induction coils and capacitors which have been specially calculated for optimum filtering e Equipment sized under rated conditions for 1500W motor test bench controlled by frequency converter e Compatible with our frequency converters pages 95 98 e Supports the max effective line current 15A H3 max 1OA H5 max 5A e Wiring consisting of 4mm safety leads e Supplied with instructions for use and tutorials e Easy to move thanks to its wheels e Dimensions 450 x 450mm Height 530mm Weight 73kg 4 728 Akp PP pep controllers Examples of line current measurements see Pages 95 98 taken with our 6830 network analyser Page 239 on HARMOVAR associated 3 441 AD Hz 58 PE 13 with our ACVARS frequency converter That 53 6 SEC 64C Page 95 H3 filter activated f 7 2 aai Ark Peep meae me a a nemen a EE P SaR me a aa ae ae ae aa moe ae mon DB Ast 150 Hz HZ 50 0 gB 35 541 149 A Thd 148 6 SEC 64CT IUT 2a o e ee eeeee btto e666 e e s6668 H3 filter deactivated 192 CE PRODUCTS 2 YEARS GUARANT
69. indows etc e 1 optical smoke detector with its own aerosol EQUIPMENT e 1 stand alone alarm unit powered by mains and battery e 1 power supply for the sensors e 2 infrared detectors e 1 keypad for code entry 4 numbers e siren e 1 flashing light e magnetic door opening detector fitted on the window e 1 PLC Schneider Supplied with programming software and communicating software Vijeo Designer telephone interface e 1 telephone e 1 telephone transmitter carries out all ref GES 3 COM the alarm transmission and reception functions The panel is fitted with a stand alone telephone line Doesn t require the public telephone network EDUCATIONAL OBJECTIVES EDUCATIONAL OBJECTIVES Understanding and settings a wireless anti intrusion unit Programming of the different components of an anti intrusion unit like the main unit the sensors the keyboard the ringing alarm the autocom PBX the transmitter the remote controllers USER S MANUAL PRACTICAL WORKS Understanding and settings an anti intrusion unit Programming and setting of the Schneider PLC for the COM version Understanding and use of the supervision on PC for the COM version Understanding of an IP network for the COM version USER S MANUAL PRACTICAL WORKS LIGHT CONTROL IN A BUILDING EQUIPMENT e educational reinforced electrical cabinet and modular equipment e 1 push button operated remote dimmer sw
70. ing Push pull output on speaker Wheatstone bridge ref ELEC9 Photoresistor characteristics Using a switch Thermistor characteristics Wheatstone using Thyristor drived by thermistor 3 stages amplifiers controled by microphone ref ELEC10 Blocking oscillator Blocking oscillator with speaker output Astable multivibrator LC resonant circuit Electronic birdcall circuit ref ELEC11 197 CIRCUIT LAB Digital logic lab Be Gif Ora aye Digital logic lab equipped with a P ry oeGoe00GCeeORCS Oe eh a ee a a main unit and 13 experiment fiarr TELLEF There LEETE modules Each module permits to realize several practical works r er Supplied with leads and user s manual l Se eas Tt at a ry Epis eee E EDUCATIONAL OBJECTIVES Studying by different modules of logic circuits commonly encountered TEACHING RESSOURCES PRACTICAL WORKS dm E a iia ii br b Ha EES LS pa En jaun rea Tye ity tate m zi T EELCEETET E a mnr fe S Shits at ie TONANATOAN Lope CE FAPEBMEN won fa ie ae _ ate pa E Pin e a a ref PSY3101 PSY3101 MAIN UNIT WITH 4 fixed DC supplies with output overload protection 5V 5V 12V 12V 300mA on each output 1 adjustable DC power supply with output overload protection from 1 5 to 15V 500mA 3 fixed frequencies
71. itch to control the spotlight brightness e 1 push button operated remote dimmer switch to control brightness and a presence sensor e 1 dusk to dawn switch e 1 push button operated timer with switch off warning e presence detector with dusk to dawn cell to control a fluorescent tube e 1 daily timer switch with infrared presence detector to control an incandescent lamp e 1 PLC Schneider Supplied with programming software and communicating software Vijeo Designer ref GES 11 COM EDUCATIONAL OBJECTIVES Understanding and settings of a light control system with various sensors Programming and setting of the Schneider PLC for the COM version Understanding and use of the supervision on PC for the COM version Understanding of an IP network for the COM version Side with push buttons Side with electrical cabinet USER S MANUAL PRACTICAL WORKS and spotlights presence and brightness sensors C PRODUCTS 2 YEARS GUARANTEE 155 TRAINING PANELS security lighting control system Front view CONFIGURATION SOFTWARE for the addressable self contained emergency lighting unit supplied with GES 41 and GES41 COM User friendly only a few minutes are required to start using this software Each self contained emergency lighting unit has its own address Configuration information and faults detected on the self contained emergency lighting units are permanently stored in a database PC connection using
72. le and all mains leads necessary for proper operation CSRERODUCT P2 Fok CUA NIE 179 REGULATION system for water level amp flow regulation by PID Satie puissance PID Entr e varisteur Ge r g Entr e Variateur de frig Terminal block with inputs and outputs of variator control and PID sensors disturbance valve e Power supply 230VAC e Overall dimensions 1100 x 670mm Height 1980mm Weight 104kg ref DESNIV OPERATING PRINCIPLE W__lW_____ The objective is to adjust the water level in a transparent polycarbo nate column diameter 160mm height 1370mm A pump draws the water from a 50 litre tank at the bottom of the column The water constantly flows through the setting valve from the column towards the tank under gravity The PID regulator receives the water level information from a 4 20mA sensor It compares this signal with the level reference and controls the pump delivery via a frequency variator The system operates in two modes servo control and regulation In regulation mode a manual valve creates the disturbance Pressure sensor and disturbance valves Wired grid including with a speed controller 180 CE PRODUCTS 2 YEARS GUARANTEE EDUCATIONAL OBJECTIVES Studying putting into service getting started and setting of the system Understanding and setting of the PID level regulation Calculating the span amp zero offset of a l
73. ly to within a tenth of a degree The DESP model uses only industrial components The PID control system 4 20mA standard for measuring input and out put controls air stream temperature To prevent any risk of burning oven power has been limited to 250W and air temperature to 100 C The student wires the Pt100 3 wire probe 4 20mA mea suring loop 4 20mA control loop temperature transmitter and loop power supply to the terminal strip Current is measured at the conversion resistance using a multimeter without opening the loops Maximum accessible voltage without dismantling the apparatus 24VDC The system operates in two modes automatic and control In the latter case an adjustable speed fan sets up a disturbance The terminal strip and components are suitable for demonstrating all types of wiring errors and trou bleshooting The temperature and thermostat control current graphs used to determine static loop and critical gains as well as dead time and the time constant are produced either manually possible due to the slow changes in temperature or on a PC using LOGIFOUR software option and PC interface In aeronautics gluing techniques between metals and composite materials require accurate temperature of polymerization glues to ensure maximum grip This model of oven of glues polymerizing which the airflow is used to carry the parts to be glued to the appropriate temperature has a PID temperature regulation accurate to
74. mensions of each module 250 x 165 mm e Total weight 50 kg OD hae er ides Ls ee bl i mi rimar cae cimae ae ee aa l TE pm mi si ki Amiha Additional KNX modules See Page 54 study system for the KNX bus wr TRAINING SYSTEMS amp MODELS EDUCATIONAL OBJECTIVES Studying KNX communication media Studying the principle of a home control installation with KNX devices Configuration of KNX devices Creating the wiring of KNX devices Creating home control scenarios TEACHING RESOURCES STUDENT amp TEACHER Practical works e Creation of the complete wiring diagram e Study the creation of KNX wiring and programming for the functions of lighting control shutter and opening control using pushbuttons e Creation of home control scenarios like using a single key to switch off the lights lower the blinds and open the garage door and the gate e Combine several different brands makes with the same KNX standard ref DOMO KNX The KNX bus offers a standard of compatibility and interoperability that is unique and global in the home control sector With KNX PARTNER certified manufacture the DOMO KNX model enables the study and putting into service of multibrand KNX products SCHNEIDER and HAGER other on request The KNX devices are prepared in plastic housings with the front engraved and equipped with 4mm terminals The wiring of the Bus and the power are then created using safety leads We
75. mitt trigger window type comparator ref ANALOG16 Operational amplifier oscillators Monostable and astable multivibrator square wave generator Sine wave oscillation circuit RC oscillator Wien oscillator ref ANALOG17 CEERODVUC T 2 EokoeCeRAINIE TRAINING SYSTEMS amp MODELS STUDENT BOOK supplied with each module e A theoretic part definitions terminology charac teristics curves schemas theoretical schemas and wiring diagrams with link slots The functio ning is explained in details e An experimental part to guide step by step the student to do practical works choice of measu rement appliances settings measurement to do blank tables to be filled curves to be drawn e Result commentaries additional practical works INSTRUCTOR BOOK supplied with each module e Practical works presentation purposes manipulation interpretation e Switches position to simulate troubleshooting e Detailed and pedagogical solutions of practical works e Calculation shown in extenso Moreover the instructor will find technical complements which can be distributed to students without any modifications CIRCUIT LAB Conversion test benches RECTIFIER SINGLE PHASE DIRECT CURRENT CONVERSION TEST BENCH Ga CO 1000 IS SUPPLIED WITH 4 MOVEABLE FRONT PANELS INSTRUCTION BOOK INCLUDED TUTORIALS CEIIO10 CATIII pol2 300V CLI ref CO 1000 EDUCATIONAL OBJECTIVES Studying of the controlled no
76. mm Total height 1970mm Weight 118kg CE PRODUCTS 2 YEARS GUARANTEE 195 MOTOR SYSTEMS ref MICROMAG SCOPE OF SUPPLY Supplied complete and in working order together with e 1 wound stator e 2 additional bare combs for winding e enamelled wire dia 0 5 mm e 14 leads dia 2 mm e 1 full set of instructions with amended tutorials EDUCATIONAL OBJECTIVES Identifying the internal components of a auto controlled synchronous machine theoretical and practical Functioning in motor and in generator Achieving the coils and set the switch TEACHING RESOURCES MADE BY THE SCHOOL ENSEEIHT MICROMAG uses only dry contacts with no complex electronic circuit so that its operation is accessible to everyone Using this model students discover little by little the various components of an automatically control led synchronous machine and more generally of a motor via a theore tical and practical approach The theoretical approach can be accessed at different study levels At the secondary school level the torque the EMF and the number of turns in the winding are calculated simply by ap plying formulae Engineering students will have the necessary mathema tical knowledge to establish these relationships by using the laws of electromagnetism and applying them to the MICROMAG machine MICROMAG comes with a manual containing all of the basic laws which are necessary for understanding the tutorials Wherever n
77. n controlled and mixed rectification of the single phase All types of practical tests on the rectification of controlled and uncontrolled single phase current can be carried out with this single box which comprises built in supplies including a power supply a probe for measuring the AC DC current output an ignition angle display and 4 switches to change from the diode assembly to the rectifier assembly The test bench is supplied with 4 movable front panels Each one is a specific mask with holes for the in dicator lights input output terminals and switches requi red for a particular set of tests Each panel is printed with the instructions for just those tests None of the components are directly accessible to avoid short circuits Rectifiers and diodes are specially mounted to facilitate maintenance and are visible behind a movable transparent cover The 30V x 6A output is capable of running a powerful motor elec trical power 150W mechanical power 90W connected to a brake making it possible to observe the influence of braking on the conduction angle The instruction book supplied with the test bench explains the tests listed below for each front panel RECTIFIER CONTROL The ignition angle is controlled by a potentiometer and dis played The control pulses applied to the trigger through separation pulse transformers are output via BNC to the oscilloscope CURRENT PROBE This probe consists of a Hall effect sensor and i
78. n to a DC motor power supply Any of these 4 diodes can be replaced by a rectifier at any time simply by throwing the appropriate switch This facilitates comparisons between all diode all rectifier symmetrical mixed and asymmetrical mixed assemblies MONTAGE A veve verstos eT TeaNsronmaTEURAPonTMuss PANEL C ASSEMBLY WITH TWO RECTIFIERS es AND MID POINT TRANSFORMER Ha Controlled single and double wave rectification The tests on panel A may be used again for comparison PANEL D BRIDGE CIRCUIT ASSEMBLY MONTAGE EN PONT ALL RECTIFIERS OR MIXED Comparative studies of diode rectifier mixed assemblies Experiment 1 Power flow on active inductive load E R L Operates as a static convertor Operates as a grid interactive inverter Experiment 2 Application to a DC motor power supply DCM Mixed bridge circuit assembly Experiment 3 Power flow on active inductive load E R L Experiment 4 Application to a DC motor power supply DCM 202 C PRODUCTS 2 YEARS GUARANTEE INVERTER TRAINING SYSTEMS amp MODELS SINGLE PHASE CONTINUOUS ALTERNATING CURRENT CONVERSION TEST BENCH ea CO 1000 IS SUPPLIED WITH 2 MOVEABLE FRONT PANELS INSTRUCTION BOOK INCLUDED TUTORIALS ACCESSORIES FOR CO 1020 Ref ECO 10 Ref ECOI Z 150 Rel ECON 779 Ref ECOI 2Z 35 Rheostat ECO1 2 102 P 110 Rheostat ECO1 2 15 P 110 Rheostat ECO1 2 22Q P 110 Rheostat ECO1 2 33Q P 110 for an optimal use low resis
79. ng software In the practical works the sequences of programming of each components is provided in the form of video files for a better understanding of the student HMI Human Machine Interface Composition of the model Power supply from mains 230V 2P E e power supply unit with user and appliance protection 30mA distributes voltage 24VAC to the speed controller for the PLC HMI offset I O interfaces and 230VAC 2p E e 2 machine boxes each with 3 PB 3 switches 7 indicator lamps and 3 PB and 3 switches for simulating sensors e 1 PLC Ethernet 24 inputs 16 outputs e 1 PLC Ethernet 14 inputs 10 outputs e 1 ETHERNET switch 5 ports RJ45 e touchscreen HMI 3 8 with Ethernet ports e 1 speed controller ATV32 0 18kW e 1 asynchronous motor 230 400V 0 12kW with fan for viewing rotation e 1 multifunction programming graphic terminal with large monochrome screen 8 lines 240x160 pixels for programming the speed controller 1 set of Ethernet leads e 1 set of Ethernet mounting connectors e 20 metres of Ethernet cable e 1 software for PLC programming e 1 Vij o designer software for programming the HMI e 1 SoMove software for programming the speed controller ATV32 e 1 DVD includes the instructions for the different components and the practical assignments and programming examples for the PLC the speed controller and the HMI video HMI Human Machine Interface b a E ee ee TENERE Ta q F AITT
80. ng version Understanding of the link resistance temperature as measuring principle USER S MANUAL amp THEORETICAL COURSES Set of components for the study of a All or Nothing temperature regulation loop with a PT100 temperature sensor and 4 20mA signal Understanding and wiring of a regulation chain All Or Nothing 0 iT These solutions of regulation are delivered with all the necessary safety leads __ PT100 Signal a user s manual for each component and also wiring diagrams fe A ORNO REGULATION LOO ref REGULOR standard model ref REGUL S communicating model MAIN COMPONENT STANDARD VERSION MAIN COMPONENT COMMUNICATING VERSION TOR2002 BOX Ce RA A COMMUNICATING REGULATOR TOR o Ref TOR COM REGULATOR TOR pini NERE D 3 See Page 188 Ref TOR2002 BOX See Page 188 x Fy LIGHT HEATING UNIT A Ry Ref CHT V7 Ref RH BOX See page 187 see page 55 PT100 TEMPERATURE PT100 TEMPERATURE SENSOR CONVERTER Ref PT100 BOX Ref TMPT BOX See Page 187 See page 187 184 CE PRODUCTS 2 YEARS GUARANTEE TRAINING SYSTEMS amp MODELS PID temperature regulation EDUCATIONAL OBJECTIVES Understanding and wiring of a regulation chain of temperature by PID Studying setting control of a PID regulator Retrieving information by computer communicating version Understanding of the link resistance temperature as measuring principle USER S M
81. o the 400 and 24V power sources and to the control panel TECHNICAL FEATURES OF THE CONSOLE Console which makes testing safe with control of the cabinet door s safety contact Circuit breaker in front of the power source General residual current circuit breaker 30mA General emergency stop and Start Stop 2 circuit breakers for protecting the three phase and 24V power supply DOOR OVERRIDE Key operated door override switch Allows the live cabinet to be used with the door open if the switch has been activated Operates with a different key to the No 455 CEEROPDVUC T 2I EAR I CUVUARANIEPE TRAINING SYSTEMS amp MODELS Drinking water supply simulator operative part only WATER PR TRANSPARENT TANKS MADE TOWER i FROM UNBREAKABLE LEXAN RAPID CONNECTION INTERFACE FOR THE PUMPS This unit is plugged directly into the mimic console transforming the 12 safety terminals 4mm into a HARTING industrial rapid connector ref CHATO SYSTEM DESCRIPTION e 1 150 litre tank simulates the river e 2 transparent tanks 60L simulates the settling basin and the water tower Fitted with 3 water level sensors All or Nothing e moto pump draws the water from the river to the basin e moto pump draws the water from the river to the water tower e tap simulates the water consumption The water flows from the water tower to the river e 1 valve drains the settling ba
82. oad equipped with 4 traffic lights Using a TCP IP PLC and monitoring software it is possible to control the model and view its operation on a computer OPERATIVE PART e 6 x traffic lights control INPUT by 24 VDC level e 4 x car detection sensor OUTPUT by 24 VDC level supplied by the PLC e 6x traffic lights manual swith on off e Interconnection DB25 plug e Dimensions 390 x 325 x 140 mm PLC PC connection via USB e model 9 output amp 7 relay inputs supplied with one interconnection wire plug link on the didactical model one programming software english french based on contact language e Dimensions 170 x 130 x 130 mm 230 240 VAC MONITORING e Traffic lights system controlled from a computer e Visual and intuitive display interface Acquisition of PLC parameters and visual control Cars and traffic lights monitoring Traffic lights control switch on off adjustement time orange flashing e The software visual editor allowed to adapt the basic settings and to change software visual interface Large possibility of use according to your particular teaching needs FEATURES OF THE ASSEMBLY e Dim 390 x 325 x 160mm e The assembly is supplied already wired with a monitoring example and all mains leads necessary for proper operation 178 CSRRODUCT T2 Fok CUA NEE TRAINING SYSTEMS amp MODELS LIGHT SIGNS SYSTEM FOR A MOTORWAY TOLL PUMPING STATION Simulates a motorway toll Comprises 1 ele
83. oad protection 5V 5V 12V 12V 300mA on each output 1 Dual DC power supply with output overload protection 3V 18V 1A continuously adjustable 2 AC power supplies with output overload protection O 9VAC 500mA Signal generator Sine square and triangle 10Hz to 100kHz 4 ranges 100Hz 1 10 100 kHz REF ANALOG 3 Output impedance 509 Output voltage 9Vpp with 50Q load 18Vpp open loop 3 1 2 digit digital voltmeter ammeter Range 2V 200V accuracy 0 3 Range 200pA 2A accuracy 0 5 Analogue voltmeter ammeter O to 20V DC 0 to 100mA DC O to 1A DC O to 15 V AC O to 100mA AC 0 to 1A AC Speaker 8Q 0 25W with driver circuit 0 25W potentiometers 1kQ 10kQ 100kQ 1MQ Breadboard 1680 tie point breadboard wich can be easily put into and taken off permutable with the modules Dimensions 400 x 300 x 130 mm Weight 5 8kg i eg REF ANALOG 200 C PRODUCTS 2 YEARS GUARANTEE Silicium Germanium Zener Photodiode and LED diode characteristics experiments Clipping and clamping circuits ref ANALOGI Half wave and full wave rectifier circuit Bridge rectifier circuit Dual power rectifier circuit Voltage doubler amp multiplier circuit RC direct current charge amp discharge circuit Differentiator integrator RL charge amp discharge circuit NPN and PNP circuit IE IB IC measurement ref ANA
84. of a decade box not supply e Establishing a calibration sheet drawing the calibration curve e Identifying and testing of a Pt100 probe Calculation of the current through the Pt100 probe e Measuring of a loop current without opening the loop e Using a 4 20mA calibrator e Establishing the functional diagram and determining the role of different components e Establishing the loop diagram of regulation and the wireline diagram e Identifying the controlled value the monitoring value the disturbance values e Determining the direction of action of the regulator according to the direction of the process and the direction of the correction member e Determining the static characteristics of the process static gain timeout time constant in order to calculate the transfer function e Determining the oscillations period and the gain of the critical loop the integration factor Determining using models Broida and Pessen correctors P and D e Viewing of the response curves with 3 correctors P and D e Adjusting of the PID correctors and testing according two methods enslavement and regulation e Testing of different empirical methods for adjusting PID correctors e Troubleshooting training by fault simulation FEATURES e Supply 230VAC e Dimensions 350 x 200 x 122 mm e Weight 3 7kg This small oven where an air stream is used to bring the parts to the correct temperature is equipped with PID to control the temperature accurate
85. onance phenomenon It is also possible to study the operation of the phase shift of the SCR regulator Principle the industrial lighting of the panel simulated by the four halogen lamps on a tripod varies depending on the ambient sunlight simulated by one low voltage spotlight placed in the cabinet When the current in the halogen lamps is significantly degraded the filtering components are activated either manually via the switches on the front or automatically by a PLC Auto mode 3 sunlight levels are programmed For weak sunlight the 3rd order current harmonic is high The PLC activates a passive filter which tends to decrease this harmonic Manual Mode a potentiometer is used for continually adjusting the sunlight level Varying it makes it possible to Lille e VIEW with the help of the network analyser ref 6830 the effect of the dimmer on the level of the current harmonics fare HST eae RO NE e MEASURE THE power factor by inserting a capacitor induction coil The network analyser reveals that the solution Thd 36 8 SEC 64CT SUT 2a can be found in the induction coil Lighting provided 50 with passive filter reduction e FILTER HARMONIC 3 by using a resonant filter which will reduce noticeably its current of third order harmonic THE FRONT PANEL COMPRISES OTHER FEATURES e Safety terminals for the measurements e Light column indicating that the mains power is on voltages and currents supplied by the network e PLC Software
86. only operate once the console has been connected to an external electrical cabinet MIMIC CONSOLE ALLOWING ELECTRICAL CONNECTION e 1 HARTING rapid connector on the console for connecting sensors the cashier unit and the status indicator light 1 set of safety terminals on the console bringing together the wiring for the motor s terminal board e This area can take a HARTING rapid connection interface if the user does not have any electrical measurements to take from the motor CASHIER UNIT CONNECTED TO THE CONSOLE It comprises all of the various controls that the cashier requires e Till open push button e Last customer push button e Information request push button e 3 position switch 1 Forced belt operation The belt will continue to move forwards 2 Automatic operation of belt The belt will move forwards depending on the objects that are placed on it 3 Switch off belt STATUS INDICATOR LIGHT CONNECTED TO THE CONSOLE Indicates the status of the till to customers e Green till open e Orange last customer e White Call PHOTO ELECTRIC CELLS CONNECTED TO THE CONSOLE e Placed at the start and end of the belt they detect the presence of an item on the belt which in turn activates the belt that items are building up at the end of the belt which in turn shuts down the belt e These cells are of the NO dry contact output type GEAR MOTOR Three phase 230 380V The motor s termin
87. pable of all variable frequency controls CONTROL MODE The control mode is selected by pressing the MODE key e SYMMETRICAL e OFFSET e BIPOLAR PWM e THREE POLE PWM A LED indicates which mode has been selected SELECTING ADJUSTMENT PARAMETERS Adjustment parameters are selected by pressing the SELECT key e FREQUENCY Hz e OFFSET ANGLE e 1st ANGLE a IN PWM e 2nd ANGLE b IN PWM A LED indicates which parameter has been selected In PWM mode the signal pattern is determined by the size of the angle a b selected which amounts to setting the pulse width Depending on the values of these angles it is possible to eliminate the 3rd and 5th rank harmonics to obtain a spectrum with fewer harmonics closer to the sinusoid curve CURRENT PROBE This probe measures AC DC and AC DC current and is connected in series like an ammeter in the circuit to be measured A BNC terminal displays an image of the current intensity at a voltage of 1 V A Variable coil P 117 12V 24V Battery Single phase transformer 12V 230V wth its lamp 230V 40W load made up of a 40W machine 12V 230V Capacitor 22uF PANEL A SINGLE PHASE STATIC HALF BRIDGE VOLTAGE CONVERTER 2 SWITCHES The diode and power transistor operate by cross barring Presentation of symmetrical control Presentation of the Pulse Width Modulation control Bipolar PWM wave Experiment N 1 Throughput over resistive load R Experiment N 2 Throughput o
88. parameters e display of the speed controller s power in correlation with the pump delivery e adjusting the settings A 5 _ m A E E 5 Removable grid quickly taken through Harting plugs Example of monitoring on the touchsreen 182 CE PRODUCTS 2 YEARS GUARANTEE TRAINING SYSTEMS amp MODELS ay ee E ee ee ee ae aT ee a ee CO oOooooo0oo0o0000000 24V Conductive PLC Probes ooooo0oo0oo00000000 ETHERNET RJ45 A N CONTROL AN Level sensor 24V 24V RES INDICATOR LIGHTS CONVERTER OOOO OO ON OFF Signal jo OFF Signal c E 4 F Pressure sensor PPER TANK OTEO s MANUAL VALVE FLOW SETTING E WATER PUMP SS COMPUTER po UTILISATION NSONDES sj Dinda Enna PD a Sase inmsin Toce Retour page d acceuil f Automatic drawing of the measuring value order value PID status on the touchscreen english version available Probes status on the touchsreen english version available CSERODUCT T2 Fo CUARANIEE 183 REGULATION All or nothing temperature regulation Regulator output Mains input gece 220V w EDUCATIONAL OBJECTIVES EEE 1 ei ala PT100 gt E E Te t Studying setting control of a All Or Nothing regulator gumm Retrieving information by computer communicati
89. pervision on PC for the COM version e Understanding of an IP network for the COM version Monitoring software supplied Allows you to acquisition and display of PLC variables monitoring and control of the process you to create your own monitoring Displays battery operated the presence of a voltage on the lighting unit terminals Controls the activation of the anti panic unit the activation of the security lighting units TECHNICAL FEATURES AND EQUIPMENT e educational reinforced electrical cabinet and modular equipment 230V AC power supply Protected by circuit breakers including one 30mA e The unit is supplied fully wired in working order with a wiring diagram operating principle and detailed instructions for each component Front panel Units power supply from a central source e 2 LED EVACUATION lighting units e 2 LED MOOD lighting units e 1 BTM modular remote control e 1 switching unit controlling the MOOD lighting units e 1 central source LSC equipped with a sealed battery 48V 160W voltage 4 fuse outputs digital display of the operating voltage drain current indicator lights for the mains power on battery operations battery charging and faults e 1 forced operation switch for the MOOD lighting e 1 spotlight connected to the mains showing its presence Back panel Power supply for the stand alone units e 1 addressable LED MOOD and self contained emergen
90. provement of accuracy using an angle sensor e 4 BIT GRAY ENCODER GRAY DCB code comparison A synchro sensor is required
91. ration and programming of the video sensor using the software e Wiring of the conveyor belt vision sensor and position sensor MAQ VISION is a model equipped with a vision sensor combined with configuration software for Testing with different part samples part surveillance and recognition by video This type of automatic visual quality control is nowadays used on many production lines It enables the checking of parameters like presence position orien tation sorting integrity and marking It is also used for guiding before gripping The image of the reference part and its acceptance tolerances are saved in the sensor s memory The good part or Composition of the model bad part result is obtained from binary outputs e Power supply unit magneto thermal protection device MAQ VISION is equipped with a motorized conveyor belt 24VDC It carries the part under the sensor and indicator light for checking An indicator light signals if the part is conform or not e Motorized conveyor belt 24VDC Supplied with the video recognition programming software e Colour vision sensor on height and tilt adjustable support e Binary position sensor peetares e Indicator light for nonconform part e 2 metre mains lead for power supply e Dimensions of the housing 240 x 180 x h 130mm e Dimensions of the conveyor belt 300 x 110 x 120mm e 1 Configuration software e 2 part samples conform and nonconform C PRODUCTS 2 YEARS GUARANTEE 1
92. rder to determine the capacitor bank necessary Role of automatic compensation e Study of resonance max min current The MAQCOS model is designed for studying and rectifying power factors It consists of three branches e source branch S representing the energy supplied by the electricity mains Network e plant branch L symbolizing a plant s energy consumption e plant branch C including the padding condensers integrated in the model and connected using jumper wires Each branch is equipped with the same measuring instruments e ammeter e wattmeter measuring active energy e Power factor meter measuring the power factor e varmeter measuring reactive energy Students are thus able to compare four electrical variables in the three branches at the same time They will observe surprisingly that the source current value in the mains network branch may be much lower than the value in the plant branches That source reactive energy is close to zero when power factor is around 1 whereas plant reactive energy is at maximum value The model shows the impact of a power factor regulator on the cost per kWh transmitted and the resulting electricity bill MAQCOS is supplied with a fluorescent tube and IPXX connection TECHNICAL SPECIFICATIONS e 13 displays 3x A 3 xW 3x power factor 3 x VAR 1x V e 10 condensers 0 1pF 41 pF e Fuse protection e Dimensions 510 x 400 x 150 mm Weight 8 2kg VARIABLE INDUCTANCE OPTION
93. ree phases in anti series and parallel They produce a phase power diagram based on the rotor s angular position EXAMPLE 2 The MICROMAG winding can include one two or three notches per pole and per phase Students perform a theoretical calculation to determine the number of notches and turns of the winding required for a torque specified by the teacher They then perform this winding on a comb using enamelled wire Next they check the obtained static torque in practice using a dynamometer EXAMPLE 3 Using these diagrams students study the principle of the switch which powers in sequence the phases of a synchronous machine based on the rotor s angular position This switch comprises a position sensor and electrical switching This is performed in MICROMAG by means of a rotating disk which is synchronous with the rotor and carries magnets The magnets activate reed switches in series with the windings Students have to place the magnets onto an angular sector of 120 on the switch s disk in order to power two phases It is also possible to perform a 180 control by using one anti series phase and the other two in pa rallel By manually activating the disk students check on the ohmmeter whether the opening closing sequence of the switches matches the previously established phase power diagram exactly based on the rotor position EXAMPLE 4 Students place the windings that they have produced inside the motor By manually powering one p
94. rial supplied Operates with a different key to the No 455 The monitoring is fully developped and operational 6S PRODUCTS 2T EAR QualyalN ce 163 TRAINING SYSTEMS Drinking water supply simulator ViieoDesigner schneider SYSTEM DESCRIPTION TRANSPARENT TANKS MADE FROM UNBREAKABLE LEXAN e 1 150 litre tank simulates the river eee p E e 2 transparent tank 60 L simulates the settling basin and the water tower WATER TOWER Fitted with 3 water level sensor all or nothing e 2 motorised pumps draws the water river to the basin basin to the water tower e 1 tap drains the water tower e 2 all or nothing flow sensors e 1 valve drains the settling basin e 2 valves at the motorised pump output to adjust the flowrate of the water e 2 emergency overflows e test cabinet with PLC Analog card and Ethernet e Protection main control panelwith circuit breakers including one 30mA control and consignment THE MONITORING ENABLES TO DISPLAY e The water levels e The settling basin pump feed e The water tower pump feed e Movement of the water from the river into the settling basin e Movement of the water in the settling basin to the water tower Low water level warning message for each tank THE MONITORING ENABLES TO CONTROL e the settling basin pump feed manually e the water tower pump feed manually e the cycle start e MANUAL AUTOMATIC MAINTENANCE mode THE MONITORING ENABLES TO
95. rier a switch and a solenoid e Possibility of making other lines optoelectro barrier reed relay Hall sensor electronic switch buzzer ACCESSORIES SUPPLIED 1 set of leads 2mm 2 x 100cm 2x 50cm 3 x 30cm 3 x 15cm a PRACTICAL WORKS e Study of the principle of a stepping motor and its different ways of functioning by step and half step e Vibrations seen at low frequency loss of steps at high frequency e Determination of the take in resonance frequency and of the rotation limit frequency e Observation of signals delivered by the driver to the motor windings e Inversion of currents in the motor coils e Observation of 4 signals applied by the control logic to the driver out of phase with one another PRACTICAL WORK WITH COMPUTER A program in basic and working in DOS is supplied This completely listed program can be freely copied and if necessary modified by the user In particular it allows control of the speed and direction of rotation CSERODUCT P2 Fok CUA ANE TRAINING SYSTEMS amp MODELS Position feedback Es Et E53 ref B3510 J This model is designed for the simplified PRACTICAL WORKS study of a closed position feedback loop e Study of the principle of a closed feedback loop error It is composed of a direct current motor voltage pre amplification driver stage push pull the rotation of which drives a worm e Study of limitation of movements circuits screw e Anti jamming
96. rstanding the different ways of starting an induction motor TEACHING RESSOURCES PRACTICAL WORKS Proposed Practical Works Studying of the functioning star delta starting direct by frequency converter by soft starter Statement of engine characteristics taking measurement of U and Study of current transformers e Modification of the acceleration and deceleration ramp of the frequency converter e Setting the PC connection PLC ref DEMARAC System for studying the start up of asynchronous motors For this completely stand alone sys tem all you have to do is connect it to a 3 phase 400V mains socket Selection of the required motor start up type via push buttons at the front of the electrical cabinet A 300W asynchronous motor a powder brake and a tachometer generator are fixed directly onto the base with wheels The power unit and the electrical cabinet are linked together using Amm safety leads so that measurements can be taken using a hook on ammeter or voltmeter etc A key operated switch at the front makes it possible to use the electrical cabinet when it is swit ched on with the door open In this way a qualified individual may take electrical measure ments inside the cabinet A multifunction measuring unit displays the electrical quantities on the front door A digital tachometer shows the motor rotation speed A potentiometer at the front is used for varying the motor load e Dimensions Base with wheels 750 x 670
97. s e 4 height adjustable conductive probes e 1 4 20mA hydrostatic pressure sensor The water drawn from the lower tank supplies the Upper tank where the sensors are located before running away via a manual valve The PLC s PID and the variable flow pump allow a level control COMPONENTS PARTS OF THE MODEL e 1 100L lower tank e transparent 60L upper tank graduated in cm e 3 level sensors with binary float 24V 3A e 4 50cm long 6mm conductive probes e 1 hydrostatic pressure sensor Rating 4 20mA output for 0 600mm water level e Cabinet and console e 1 5 7 TFT touchscreen e 1 4 port RJ45 Ethernet hub e 1 three phase speed controller e 1 PLC with software fitted with a TCP IP interface for the RJ45 link to a PC and the touchscreen 14 Inputs 10 Binary Outputs 24V 1 analog input 4 20mA 1 analog output 4 20mA and 0 10V ogoan FRTECTION F Fs CEVERROUILLAGE 24V SA 50H SOUS HABILITATION ref REGULEAU REGULEAU Is SUPPLIED ALREADY WIRED AND READY FOR USE WITH TUTORIALS INSTRUCTIONS SOFTWARE PLC AND MONITORING PROGRAMS e 1 Vijeo Designer software with a complete monitoring program e 1 30mA residual current circuit breaker thermal magnetic circuit breakers e 230V power supply e Base with wheels brake 1500 x 750mm Weight 144kg ACTION OF THE MONITORING e starting and stopping the system e choice of level control type e water level and settings bargraphs e display and adjustment of the PID
98. s binaries up down bi directional counters Ring counter circuit Johnson s counter circuit ref DIGITAL9 JK flip flop asynchronous counter decimal divide by N preset synchronous binary decimal Constructing ROM memories with diodes RAM memories with D flip flop Constructing EPROM ref DIGITAL10 Constructing 64 bits RAM circuit Constructing Electronic EPROM circuit ref DIGITAL11 Construction dynamic scanning counter with single chip microprocessor 8 bit analog digital converter circuit ref DIGITAL12 Digital analog converter circuit unipolar and bipolar 3 digits analog digital converter circuit ref DIGITAL13 CIRCUIT LAB Analog circuit lab 17 EXPERIMENT MODULES Designed with a 215 x 165 x 30mm solid body plastic housing with electrical wiring printed on the front panel An 8 bit DIP switch located on the right top corner allows the user to simulate faults Each analogue module is delivered with 2 experi ment manuals Analog circuit lab equipped with a main unit and 17 experiment modules Each module permits to realize several m practical works Supplied with leads and user s manual EDUCATIONAL OBJECTIVES Studying by different modules of analog circuits commonly encountered TEACHING RESSOURCES PRACTICAL WORKS pip hase i kd x The t oo Fae he wR Aa E rra J ref PSY2101 MAIN UNIT PSY2101 WITH A fixed DC supplies with output overl
99. s 4mm e 10 000 counts configurable display e Settings of the display For 4mA input the user can choose the value displayed between 1000 and 9999 For 20mA input the user can choose the value displayed between O and 9999 e Setting of the decimal point e Example of a 5bars converter For 4mA display indicates 0 000 For 20mA select 5 000 for the maximum value e Output 250VAC 0 5A relay on safety sockets 4mm e Output 12VDC allow the wiring a 4 20mA loop without an external supply e Alarms high and low relay output on safety sockets 4mm e Settings offset hysteresis gain filter e Dimensions 145 x 185 x 100 mm LORD The regulator unit controls in all or nothing the supply of the load from a 4 20mA signal EXAMPLES OF USE Enter the order value directly in the regulator When the 4 20mA signal from the sensor reaches the order value the state of the dry contact changes and opens or closes the supply circuit of the load programming of the contact state NO or NC Supply of the unit in 230V power cord The communicating version has the same features and includes in 9 addition a possible programming by software and retrieving datas files curves COMMUNICATING MODEL SCHNEIDER e LCD display in 11 segments of 3 colours green red orange e 1 0 10V input 4 20mA thermocouple on safety sockets configurable from the keyboard or the software e 1relay output dedicated to heating or cooling on safet
100. s connected in series like an ammeter The current image is a voltage of 0 5 V A available via BNC INDICATOR LIGHTS LEDs indicate which rectifiers and diodes have been selec ted which transformer windings are connected to the power supply and the rectifier inverter mode BUILT IN 200VA POWER SUPPLY 2 mid point reactors 2 x 15 Vrms Power supply 230VAC 50Hz 250VA Dimensions 670x370x170mm Weight 5 2kg ACCESSORIES FOR CO 1000 Ref ECO1 2 10Q Rheostat ECO1 2 102 P 110 Ref SH90 24 Motor 90W P 72 Ref FR90 Powder brake FR90 P 73 Ref PSYJR Variable coil P 117 Ref CO 104 Smoothing coil 40mH 3A L gt Advised option Ref CO 105 Smoothing coil 20mH 3A Ref CO 108 Smoothing coil 60mH 3A Ref CO 106 12V 24V Battery MONTAGE A DEUX DIODES ET TRANSFORMA TEUR A PONT MILIEU PANEL A ASSEMBLY WITH TWO DIODES AND MID POINT TRANSFORMER Return to single half wave rectification and switching to double half wave rectification by simply adding jumper straps Experiment 1 Power flow on resistive load R Experiment 2 Power flow on inductive load R L MONTAGE EN PONT DE DIODES PANEL B DIODE BRIDGE CIRCUIT ASSEMBLY po ee E i a Ti l O E aw 2 i Experiment 1 Power flow on resistive load R id Experiment 2 Power flow on inductive load R L ie o7 Experiment 3 Power flow on active load E R ean Experiment 4 Power flow on active inductive load E R L Experiment 5 Applicatio
101. sed to simulate the faults which occur most frequently The principle and the instructions have been devised by teachers who want to propose a method for diagnosing faults PRINCIPLE Faults are recreated when the teacher rotates a single switch Students can take measurements or perform tests in complete safety regardless of the fault type Faults can be looked for inside the student unit and in the motor terminal The unit is isolated from the mains by means of an insulation transfor mer In addition a TT earthing system is recreated on the secondary for safety reasons Therefore even isolation faults are detected by a 30mA differential mechanism All safety measures are implemented in order to protect individuals and equipment See the faults in the description of the teacher unit TEACHER SIDE UNT __ _ The teacher uses this lockable area to manage faults activated by key switches he she knows and to viewall mn y of the simulator s workings Thanks to indicator light i ae The position of the switches and indicator lights remain invisible to students The following faults are possible e 3 faults involving damaged coil A resistor is connected in series with a coil to change its impedance One switch per phase or three switches e 3 faults involving power being cut in a coil The power is cut in a coil One switch per phase or three switches e 3 faults involving a short circuit in a coil
102. sin Flow rates are adjusted by 2 valves at the output of moto pumps e 2 safety overflows devices on the upper parts of tanks avoid any overflow e 1 set of 2 cables 3m equipped with female Harting connector can connect the operative part on your connection box of a control unit e 750 x 1500mm base on wheels enables you to move the system easily e mimic console quick connection interface MIMIC CONSOLE All the connections and measuring are made on this user friendly mimic console e 1 male HARTING connector on the left section is connected to the 6 water level sensors e A synoptic indicates the function of each connection and the main features of the system e 12 safety terminals and 1 earth socket 4mm are connected to the electrical windings of the moto pumps The student is able to measure the currents with a multimer CONNECTION BY SAFETY SOCKETS OR BY MEANS OF THE QUICK CONNECTION INTERFACE e A quick connection interface 4mm terminals male Harting is plugged on 13 connection sockets for the connection to a control cabinet not supplied Set of 2 3 metre long cables supplied with CHATO A detailed synoptic on the interface shows the function of each connection e interconnection cable for sensors e 1 interconnection cable for motors CSERODUCT T2 EA CUA NEE 167 TRAINING SYSTEMS Options for drinking water supply simulator CHATO 4 amp CHATO ALL OR NOTHING FLOW SENSOR GRID amp PLATE FOR PLCS
103. system The screw cursor is integrally attached to Study of the feedback response to a voltage step for a copying potentiometer which supplies an electrical image of its position The potentiometer operated manually ACCESSORIES SUPPLIED 1 set of leads 2mm 3 x 100cm 2 x 30cm different values of loop gain determines the basic position Incremental amp absolute encoder n T reel ref B3510 R This model illustrates how an incremental encoder and an absolute encoder work They work in exactly the same way as commercial encoders However since resolution is not important in our application the num ber of sensors is limited to 5 The model has two interchangeable encoder discs with the sectors representing DCB encoding and Gray encoding When the operator turns the disc by hand the phototransistors underneath send their signals to the decoding logic and the display 4 line x 20 character LCD screen and to 4mm diameter terminals in order to control all of the control or decoding logics performed by the operator The sensitivity of the phototransistors can be adjusted depending on the ambient light PRACTICAL W ORKS _2 AMMMMMMMMMMMNANNN e 3 BIT ABSOLUTE DCB ENCODER correspondence between the position of the disc the status of the sensors and the display Transition codes and synchronisation sensor e INCREMENTAL DCB ENCODER use of the encoder in counter and count down mode Detection of the direction of rotation im
104. t four pole circuit breaker 2 double pole circuit breakers for protecting the 6 lighting circuits e 6 double pole remote control switches e 1 double pole circuit breaker for protecting the PLC e 1 connection terminal block e 6 24V LED lamps e 6 push buttons for manual lighting control e 1 3m multiwire cable for connecting the lights to the electrical cabinet PLC e with 10 relay outputs and 14 inputs supplied with a cable for interconnection with the model programming software in English French in ladder language e Dimensions 170 x 130 x 130 mm 220 240V AC MONITORING e Allows you to manage the lighting control model from a PC e Offers the basic features of a graphical tool acquisition and display of PLC variables monitoring and control of lights switching on switching off and timer e The software s graphics editor supports many applications The user can modify the preloaded demo program or create a new one FEATURES OF THE ASSEMBLY e Powered by a 230V mains cable e Metal industrial cabinet with a glazed door Dims 400 x 300 x 200 mm e Lighting console dim 400 x 330 x 200mm e The assembly is supplied already wired with a monitoring example and all mains leads necessary for proper operation T oa VO At WE GERGEEE ii ee i TTL APSE WOIE AZ Lin 19 9 la SAMSUNG p ee _ A i 7 z This model simulates a crossr
105. t practical assignments wiring tasks relevant to electrical authorization Perform maintenance and cleaning operations in an industrial cabinet Perform removal from service operations of electrical equipment Take measurements using a clampammeter TEACHING RESOURCES STUDENT amp TEACHER Practical works e Reminder on electrical authorization e Changing sets of copper busbars e Removing the cabinet from service e Complete the removal from service and authorization documents e Check correct use of PPE e Reading the current in the electrical cabinet using a clamp ammeter Comprises A e 1 main source and one secondary source 24VDC distributed on 2 sets of flat copper busbars 100A e 2 disconnectors with visible cutting for padlocking e 2 special circuit breakers DC 10A 1 set of protection devices by fuse RC circuit breaker 10A 10mA IS type e 4 gel batteries 12V 14Ah e 3 dual switches e 6 bulkhead lights 24VDC 60W e 1 battery charger 230VAC 24VDC e panel of safety instructions for electrical authorization e 1 2 colour light column indicating 24VDC on and battery recharging e 1 lot of 2 posts 5m of red and white chain e 1 insulating mat e 1 insulating blanket e 2 removal from service padlocks Features e 3 metre mains lead for battery charger e Dimensions HABILIT24 450 x 700 x h 2000mm Weight 96 kg HABILIT24 S 600 x 800 x h 2120mm Weight 111 kg 160 C PRODUCTS 2 YEARS GUAR
106. tance loads are better RESOR Ref G 06 ket G 107 Nei SOS NEL COT ref CO 1020 EDUCATIONAL OBJECTIVES Studying of a 24V single phase inverter in half bridge and in bridge TEACHING RESSOURCES PRACTICAL WORKS This bench is suitable for all types of tests on independent single phase static voltage converters It has 2 detachable front panels with holes forming a mask that reveals the layout diagram for the specific type of test to be carried out The choice of layout consisting of MOS power transistors is thus determined by the front panel slotted into the casing PANEL A Single phase static half bridge voltage converter two switches PANEL B Single phase static bridge voltage converter four switches The system includes a control panel offering the following options SYMMETRICAL OFF SET BIPOLAR PWM and THREE POLE PWM a display frequency and offset angles indicator lights control mode selection and adjustment parameters and an AC DC current probe for measuring and displaying all the current in the layout It runs both on batteries and the laboratory continuous power supply and has reinforced safety systems for reversed polarity and shutdown of unused transistors The output IMAX 3A is sufficient to run a motor of significant power and in particular to study the U F control TRANSISTOR CONTROL PANEL This flexible easy to use control panel is entirely managed by micro controller and is ca
107. ted SUPPLY 5V 1A O to 15V 0 5A 0 to 15V 0 5A 5V 0 5A aa E lt 100mV lt 150mV lt 150mV lt 30mV Load variation 100 lt 50mV lt 150mV lt 150mV lt 25mV Mains variation 15 3 CLOCKS at fixed frequencies of 1Hz 10Hz 100Hz square signal O to 5V Short circuit protected 1 SHORT CIRCUIT INDICATOR lights up when a supply or clock has short circuited 4 SWITCHES delivering between O and 5V 8 LED DISPLAYS marked 0 to 7 204 C PRODUCTS 2 YEARS GUARANTEE TRAINING SYSTEMS amp MODELS Electronic test unit i 5 oth MATA ATIF ref AT102 MICRO LEADS NOT SUPPLIED SEE PAGE 206 ELEMENT OF REPLACEMENT The central board Identical for the 3 benches AT102 AT104 AT106 For receptacle 173 x 120mm Designed for installation and rapid testing of prototypes and for practical experiments with analog and digital circuits The contact board which is hardwearing is removable Dimensions 340 x 265 x 130mm Weight 4 8kg The components are inserted on the contact board with the normal pitch spacing of 2 54mm There are 1896 contact points divided into 12 contact points of supply lines 256 separate sets of 5 contact points receiving components and interconnetions QgQaovandad LO sS T A Q8 Q Double connecteur sorties d codeur entr es 7 segments 4 SUPPLIES Positioned in view immediately on the face they are protected against short circ
108. tic phenomena and learning about the basic regulation of flow control actuator speed and detector positions OPERATING CYCLE The parts placed on the conveyor belt are held by the vacuum suction grip of a first pneumatic jack then placed on the horizontal jack grasped by the electromagnet jack undergoing a complete handling cycle before being returned to the belt PNEUMATIC COMPONENTS e 3 double effect pneumatic jacks 32mm Travel 250mm each equipped with flow reducers allowing fine adjustment of their movement magnetic position detectors 2 or 3 per actuator with LED quick fit joints for 4mm tubes e 2 5 2 electropneumatic distributors e 1 5 3 electropneumatic distributor All distributors are fitted with 24V DC coils LED visual display of the state of the coils quick fit joints for 4mm tubes fitted on mountings with silencers e Vacuum generator One of the actuators is fitted with a suction grip with its vacuum system An adjustable threshold vacuostat delivers an electrical presence or absence of vacuum signal A vacuometer allows visual checking on the vacuum e Jacks protection To avoid any risk of destroying a pneumatic jack an entirely pneumatic logic system without student access prevents the simultaneous movement of the horizontal jack with a vertical jack ELECTRIC BOX e Contains a regulated 24V DC 2A source to feed the PLC if necessary if it does not have an internal supply The necessary supplies to
109. tons for viewing and controlling the required type of start up e Multifunction measuring unit with digital display which is wired at the start of the circuit measuring the phase to ground and composite voltages the line currents the active reactive and apparent power in total the power factor the THD total harmonic distortion e Digital display showing the motor s rotation speed e Starter Decelerator Schneider All of the settings are adjusted using potentiometers on the front of the device acceleration time deceleration time and torque etc Acceleration time from 1 1 to 5 seconds Deceleration time from 0 to 5 seconds Torque adjustment from 20 to 65 of the breakaway torque of the direct motor e Frequency converter Schneider ATV31 type Possible adjustments Acceleration ramp Quick stop free wheel Pre selected speeds e 2 potentiometers at the front of the cabinet adjust the motor s rotation speed and the motor s load e Contactor circuit breaker wired upstream of the motor protect against overloads and short circuits A display built into the unit indicates the current consumed by the motor and the thermal protection threshold e 300W 400V 690V 1 0 75A asynchronous motor 1500rpm e 300W powder brake 0 10V power supply e 20V for 1000rpm tachometer generator power unit Please ask us Compatibility with motors ASUS ECE al fad otal RIAA ISA coe EDUCATIONAL OBJECTIVES Unde
110. ture curves tutorial 3 PID function from the PLC The values of the settings temperature power output and the proportional and derived coefficients are completely configurable COMPONENTS OF THE REGULAIR SYSTEM Moto ventilator 230 400V 3 phase asynchronous motor Rated speed 1500 RPM Power supply on safety sockets 4mm Electric fan shown without its protection cover e SCR power unit Single phase SCR power unit Connection by means of safety leads 4 20mA control 1 max output 15A Dim 100 x 80 x 90mm Heating unit 230V mains power supply by means of safety terminals 75W lamp Max heating temperature of approximately 90 C Can accommodate temperature probes up to 7mm in Pt100 box Pt100 Temperature Probe 3 wires Connection by means of safety leads Cable length 90cm Dim 10x 80 x 90mm PLC Unit 14 inputs 24V 10 binary outputs 1 Pt100 analogue input 2 outputs 0 10V and 4 20mA Mains power supply by means of socket unit switch PLC programming software Speed variator frequency converter 230V mains input Output to 230V three phase motor 1 input 0 10V Protection against short circuits Protection against overloads Protection against phase outages Connection by means of safety terminals Control units lamps 1 2 position switch 4 24V lamps 3Red 1Green Connection by means of safety leads 2 outputs 0 10V or 4 20mA Mains power supply by means of socket unit switch
111. uits Variable DC from O to 15V 300mA ripple 30mV Variable DC from O to 15V 300mA ripple 30mV Fixed DC 5V 1A 100mV ripple Fixed DC 5V 100mA 30mV ripple 1 FUNCTION GENERATOR From 0 1Hz to 200kHz in 6 ranges varied with a control dial The output is protected against short circuits Sinewave level variable from O to 10V peak to peak Triangular wave level variable from O to 5V peak to peak Square wave level variable from O to 15V peak to peak 2 DIGITAL DISPLAYS 7 segments and decimal point display Switched by the inputs of D1 amp D2 Direct control of each segment abcdef Access to the input of the ABCD decoder IC 1 DC DIGITAL VOLTMETER 3 1 2 digits with a maximum reading of 2 000 Ranges 200mV 2 20 200VDC Input impedance 10M 1 UNIVERSAL COUNTER 8 DIGITS Frequencymeter 1 Hz to 1OOMHz Periodmeter 99 999 999s TTL amp CMOS Internal External Input 8 DIODE DISPLAY Status from O to 7 with lamps to view logic levels 10 LOGIC SWITCHES 8 with 2 positions giving a voltage a either O or 5V 2 with 3 positions giving voltages of 5V OV 5V 2 LOGIC PUSHBUTIONS 2 anti bounce outputs A and A respectively B and B supplying a level between O and 5V on the side of the unit 4 ADAPTERS These adapters allow the unit to be connected to an external electronic unit 2 banana inputs of 4mm diameter 2 inputs of female BNC connectors CE PRODUCTS 2 YEARS GUARANTEE 205 TEST UNITS
112. ver inductive load R L Experiment N 3 Throughput over resonant load R L C n lllat SEPT a L i ga 1 SALAS ES Pii PANEL B SINGLE PHASE STATIC BRIDGE VOLTAGE CONVERTER 4 SWITCHES Presentation of offset control Presentation of the Pulse Width Modulation control Three pole PWM wave Experiment N 1 Throughput over resistive load R Experiment N 2 Throughput over inductive load R L Experiment N 3 Throughput over resonant load R L C Application to induction heating Experiment N 4 Application to speed variations in an alternating current motor Experiment N 5 Application to a backup power supply Using the CO 1000 test bench as a charger C PRODUCTS 2 YEARS GUARANTEE 203 TEST UNITS Analog test unit ref AT106 MICRO LEADS NOT SUPPLIED SEE PAGE 206 AT106 is a test bed for analog circuits Easy maintenance common circuits and diagrams provided Dimensions 340 x 265 x 130mm Weight 3 7kg Mains 230V 1 BOARD 1896 contacts with spacing 2 54 1 280 bearing the components 400 for supply distribution 4 SUPPLIES short circuit protected SUPPLY 5V 1A 1A O to 15V 0 3A 0 to 15V 0 3A 5V 100mA i lt lt 0 05 of V lt 0 05 of V Load variation 100 lt 100mV lt 50mV lt 30mV lt 30mV Mains variation 15 lt 50mV 1 FUNCTION GENERATOR Sinusoidal Square Triangular Ranges 0 1Hz 200 kHz fine adjust ment vernier Sinusoidal adjustable
113. ves the pump Students can observe a change in the flowrate depending on the valve setting 4 20mA signal output on 4mm safety terminals ref CHATO DEBIT MONITORING ON PC ONLY HYDROSTATIC PRESSURE SENSOR OPTION REF CHATO 4S This option supported by the PLC and the monitoring PLC programming software eines eta so a program measures the water level The monitoring Monitoring software VijeoDesigner _ PEL a B screen displays the levels in the tanks proportionally to i the pressure Possibility to install 2 sensors one on each The system is the same than in the version above but y tank Basin Water tower without the touch screen The monitoring is made on PC with the software SCHNEIDER VijeoDesigner e Piezoelectric measuring cell e Scale precision 0 5 CE PRODUCTS 2 YEARS GUARANTEE 165 TRAINING SYSTEMS Drinking water supply simulator with electrical cabinet not wired EDUCATIONAL OBJECTIVES Version without monitoring TRANSPARENT TANKS MADE FROM UNBREAKABLE LEXAN WATER TOWER D ref CHATO 4 GD Open solution to traditional cabling solution in electrical engineering wi ring e Door panel prewired e Free spaces for adding some control components Diam 22mm e The grid is easy to disconnect due to Harting connectors and plugs for the level sensors the moto pumps and the power supplies 400V and 24V SYSTEM DESCRIPTION e 1 150 litre tank simulates th
114. y sockets e 1 All or nothing alarm output on safety sockets e Auto setting or automatic reset e Hysteresis functions for the activation or deactivation control e 230 VAC power supply by power cord e ZELIO temperature software connection cable to PC supplied e Dims 150 x 200 x 100 mm 188 6S PRODUCTS TI EAR I QuAlyaiN ce TRAINING SYSTEMS amp MODELS PID regulators for regulation The PID regulator is the correcting component into a regulation loop for the monitoring of a process boiler compressor pump It receives a 4 20mA signal from the sensor which is the image of the value to regulate temperature pressure flow It compares it to the set point programmed in the PID and drive the process to reduce the difference process variable set point Entr e 4 20mA Sortie 4 20mA 4 20mA Entr e 0 4 Alimentation 24V DC Consigne Sortie Alarme The communicating version has the same features and includes in addition a possible programming by software and retrie ving datas files curves Alimentation 0 STANDARD MODEL T COMMUNICATING MODEL GEFRAN AT403 BOX Entr e i o Ei ES ia aay PPOs CO Sortie Alarme SOVAC SA 1 mt a ref AT403 BOX e Automatic tuning and manual PID e A digits display for the instant value e A digits display for the set point e Universal input on safety sockets Configurable accor
Download Pdf Manuals
Related Search
Related Contents
Instruments - Analytik Jena AG Foxda Tech FM-6603 User's Manual MagicCylinder II Powder coating booth DMT143 User's Guide M211435EN-D Compressed Air Brakes - Groups 00 AV-3G-XMUX User manual vm103 7” tft/lcd 2 din navigation dvd receiver 一取扱説明書・ OP27, OP37 Operator Panels Ma... - JC CARPO-KE00R00 User Manual_V3 0_120724 Copyright © All rights reserved.