Home

ASD-G9ETH Version Info (July 21, 2015)

image

Contents

1. section 10 10 2 Socket timeout resolution entered via web page Config tab increased to 0 01s increments o Increased the number of registers writable in a write multiple registers packet from 100 to 123 o Increased the number of coils writable in a force multiple coils packet from 1600 to 1968 e BACnet IP changes o Added support for output object priority arrays and relinquish default properties o Changed added supported datatypes for reading and writing object properties ref Datatypes Supported table in section 13 4 2 e EtherNet IP changes o Allow only one exclusive owner connection o Allow only one input connection instance to be active at a time e g 70 71 or 150 o Allow multiple clients to simultaneously establish input only connections O Added support for the ODVA AC DC drive profile instances 20 amp 70 21 amp 71 ref section 13 2 2 Added support for the AC DC Drive Control Supervisor and Motor Data objects Changed product type code from Communications Adapter 12 to AC Drive 2 Added the ability for the user to choose the action to take when an I O connection s run idle header indicates that the client is in the idle state ref section 10 8 3 e Web page changes o Added Modbus tab Page 6 of 8 1600 Aspen Commons Suite 210 Middleton WI 53562 Te 608 831 1255 INDUSTRIAL CONTROL COMMUNICATIONS INC Fax 608 831 2045 Email sales iccdesigns com o Corrected an issue ca
2. GSDML file e GSDML V2 0 ICC ASD G9ETH 20101104 xml e Fixed XML schema version User s manual version e 10639 2 300 000 gt 07 24 2009 Multiprotocol firmware e 2 200 release Page 4 of 8 1600 Aspen Commons Suite 210 Middleton WI 53562 Tel 608 831 1255 INDUSTRIAL CONTROL COMMUNICATIONS INC Fax 608 831 2045 Email sales iccdesigns com CRITICAL FIRMWARE UPDATE NOTE Note that the V2 200 multiprotocol firmware image name 10610a_rom bin does not follow the firmware image filename conventions used with previous firmware updates typically something like 10610a_eth_vXXXX_image bin This name change for V2 200 is intentional do not modify the filename prior to uploading it to the interface card The reason for this is because V2 200 amp future firmware releases require a one time adjustment to internal memory locations and the adjustment code contained in this firmware release will only be executed by the interface card when it receives this firmware file with the special filename 10610a_rom bin If you have any questions regarding this update process please contact ICC technical support for assistance Modbus TCP changes o Added optional supervisory timer BACnet IP changes o Added support for Reinitialize Device service o Fixed an issue whereby the priority array entries for user added objects i e BACnet objects that are added by direct XML file editing were not being properly initialize
3. UPDATE NOTE Review the V2 200 firmware release notes before updating to this firmware version e Other changes o Support P9 VLP parameters Page 3 of 8 CE 1600 Aspen Commons Suite 210 Middleton WI 53562 1 AAAA A Tel 608 831 1255 INDUSTRIAL CONTROL COMMUNICATIONS INC Fax 608 831 2045 Email sales iccdesigns com User s manual version e No new user s manual released at this time current version remains 10639 2 300 000 gt 06 01 2011 Multiprotocol firmware e 2 300 release e CRITICAL FIRMWARE UPDATE NOTE Review the V2 200 firmware release notes before updating to this firmware version e EtherNet IP changes o Added class 1 I O support for point to point unicast in the TO direction o Fixed ListServices response to correctly return the service string e BACnet IP changes o Fixed invalid character set for Device Object character string properties e Other changes o Fixed directed broadcasts when the subnet mask is set to a value other than 255 255 255 0 PROFINET firmware e 2 300 release e CRITICAL FIRMWARE UPDATE NOTE Review the V2 200 firmware release notes before updating to this firmware version e PROFINET changes o Added support for timeout processing e Other changes o Fixed directed broadcasts when the subnet mask is set to a value other than 255 255 255 0 EtherNet IP EDS file e V2 1 e Updated connection description to support point to point unicast in the TO direction
4. class 3 explicit messaging tag references expanded to allow direct access to any available register e Ethernet IP now triggers timeout processing when connection errors occur e Add support for Modbus TCP function codes 02 and 04 e Add support for PCCC protocol for Allen Bradley PLC 5 and SLC 500 series PLCs PROFINET firmware e 2 000 release Page 7 of 8 1600 Aspen Commons Suite 210 Middleton WI 53562 Tel 608 831 1255 INDUSTRIAL CONTROL COMMUNICATIONS INC Fax 608 831 2045 Email sales iccdesigns com Add Alarm monitoring functionality with email reporting Add ability to change authentication information config tab Add ability to change IP address assignments via web page config tab Add selection for writing drive configuration parameters to just RAM or both RAM and EEPROM config tab ASD interface CPU firmware V1 100 release If communication to the drive is lost then the network interface CPU is held in reset to prevent the illusion that the drive is still communicating to the Ethernet network Add support for writing configuration parameters to both EEPROM and RAM Correct an issue that causes the drive to fault with an option PCB error after resetting from any other unrelated fault All customers are recommended to upgrade their ASD interface CPU firmware to V1 100 contact ICC technical support for assistance if you currently have an interface board with V1 000 ASD interface CPU fir
5. EE 1600 Aspen Commons Suite 210 Middleton WI 53562 1 AA Te 608 831 1255 INDUSTRIAL CONTROL COMMUNICATIONS INC Fax 608 831 2045 Email sales iccdesigns com ASD G9ETH Version Info gt 07 21 2015 Multiprotocol firmware e V2 352 release e Modbus TCP changes o Added option to enable and disable the connection timeout timer e BACnet IP changes o Internal memory improvements e EtherNet IP changes o Ignore socket address info items to improve compatibility during connection establishment o Fixed get attribute single of AC DC assembly I O data e Web page changes o Changed XML TCP port to 843 to improve firewall and internetwork compatibility PROFINET firmware e V2 352 release e PROFINET changes o Updated PROFIdrive profile state machine transitions e Web page changes o Changed XML TCP port to 843 to improve firewall and internetwork compatibility GSDML file e GSDML V2 0 ICC ASD_G9ETH 20150210 xml e Limited the lowest I O cycle update time to 8ms e Updated the maximum input output and total sizes to account for overhead data User s manual version e 10639 2 352 000 gt 10 17 2014 Multiprotocol firmware e V2 350 release e Delay network communication until all drive parameters are initially scanned PROFINET firmware e 2 350 release e Delay network communication until all drive parameters are initially scanned User s manual version e No new user s manual released at this time curre
6. ccess PROFINET firmware e V2 320 release Page 2 of 8 1600 Aspen Commons Suite 210 Middleton WI 53562 Te 608 831 1255 INDUSTRIAL CONTROL COMMUNICATIONS INC Fax 608 831 2045 Email sales iccdesigns com e PROFINET changes o Modified the handling of modules after the PROFINET connection is terminated The modification will improve the compatibility with the PROFINET controller on the subsequent connection e Other changes o Modified the FTP server to improve Windows Explorer FTP compatibility o Fixed a bug where some parameters were not displaying the correct value o Internal enhancements for drive parameter data access EtherNet IP EDS file e V2 1 file revision 1 1 e Added and updated all available connections User s manual version e No new user s manual released at this time current version remains 10639 2 310 000 gt 10 19 2012 Multiprotocol firmware e No new multiprotocol firmware released at this time current version remains at V2 310 PROFINET firmware e Nonew PROFINET firmware released at this time current version remains at V2 310 User s manual version e 10639 2 310 000 e Minor documentation improvements gt 11 09 2011 Multiprotocol firmware e 2 310 release e CRITICAL FIRMWARE UPDATE NOTE Review the V2 200 firmware release notes before updating to this firmware version e Other changes o Support P9 VLP parameters PROFINET firmware e V2 310 release e CRITICAL FIRMWARE
7. d Web page changes o Fixed a bug whereby failed XML sockets were not being properly recycled This could lead to a web browser session being unable to establish a successful XML socket connection until the interface card is rebooted o Added supervisory timer selection to Modbus tab o Added Dashboard tab Other changes o Fixed a bug which prevented the SMTP authentication from being deleted once settings have been entered PROFINET firmware V2 200 release CRITICAL FIRMWARE UPDATE NOTE When migrating to V2 200 PROFINET firmware from a previous version of firmware updating to V2 200 requires an additional intermediate step not typically necessary with version to version firmware updates Prior to uploading the V2 200 PROFINET image with filename 10610a_pnio_v2200_image bin you must first upload and run the associated V2 200 multiprotocol image with filename 10610a_rom bin The reason for this is because V2 200 amp future firmware releases require a one time adjustment to internal memory locations and this adjustment code only exists in the multiprotocol 10610a_rom bin firmware image After applying the V2 200 multiprotocol image and allowing the card to reboot you may then freely apply the V2 200 PROFINET image to return PROFINET functionality to the interface card No interface card configuration information is modified or lost during this stair step application process If you have any questions regarding this update p
8. mware User s manual version 10639 2 000 000 gt 10 12 2007 Multiprotocol firmware V1 000 initial release PROFINET firmware V1 000 initial release ASD interface CPU firmware V1 000 initial release User s manual version 10639 1 000 000 Page 8 of 8
9. nt version remains 10639 2 310 000 Page 1 of 8 1600 Aspen Commons Suite 210 Middleton WI 53562 Te 608 831 1255 INDUSTRIAL CONTROL COMMUNICATIONS INC Fax 608 831 2045 Email sales iccdesigns com gt 10 08 2014 Multiprotocol firmware e V2 340 release e Added parameter F781 as requested by Toshiba PROFINET firmware e V2 340 release e Added parameter F781 as requested by Toshiba User s manual version e No new user s manual released at this time current version remains 10639 2 310 000 gt 10 02 2014 Multiprotocol firmware e V2 330 release e Improved handling and recycling of network resources e Added support for new parameters as requested by Toshiba e By default enable the option to update both RAM and EEPROM as requested by Toshiba PROFINET firmware e V2 330 release e Added support for new parameters as requested by Toshiba e By default enable the option to update both RAM and EEPROM as requested by Toshiba User s manual version e No new user s manual released at this time current version remains 10639 2 310 000 gt 05 30 2013 Multiprotocol firmware e V2 320 release e CSP changes o Added logical ASCII addressing for both Typed Read and Typed Write commands e Other changes o Modified the FTP server to improve Windows Explorer FTP compatibility o Fixed a bug where some parameters were not displaying the correct value o Internal enhancements for drive parameter data a
10. rocess please contact ICC technical support for assistance PROFINET changes o Added support for PROF Idrive profile Web page changes o Fixed a bug whereby failed XML sockets were not being properly recycled This could lead to a web browser session being unable to establish a successful XML socket connection until the interface card is rebooted o Added Dashboard tab o Added SMTP Authentication fields to Alarm tab Other changes Page 5 of 8 1600 Aspen Commons Suite 210 Middleton WI 53562 Tel 608 831 1255 INDUSTRIAL CONTROL COMMUNICATIONS INC Fax 608 831 2045 gt Email sales iccdesigns com o Added support for email servers that require authentication SMTP AUTH when sending alarm emails o Added support for changing the IP address related parameters via the drive s keypad only applies to G9 drives with V203r5 or later control board firmware or H9 drives with V204r4 or later control board firmware GSDML file e GSDML V2 0 ICC ASD G9ETH 20090724 xml e Added PROFIdrive module e Corrected Module VM_23 IN8_OUT6 input and output sizes User s manual version e 10639 2 200 000 08 29 2008 Multiprotocol firmware e 2 100 release e Modbus TCP changes o Fixed infinite looping that could occur if extraneous data remains in receive buffer as a result of an improperly coded Modbus master driver sending extra garbage bytes after the normal data packet Added register remapping capabilities ref
11. used by a new Flash Player policy file request that occurs with the latest release of the Flash Player browser plug in This would cause the XML sockets to fail on their initial connection attempt o Added Run Idle Flag behavior checkbox to EtherNet IP tab o Added SMTP Authentication fields to Alarm tab e Other changes o Added support for email servers that require authentication SMTP AUTH when sending alarm emails o Added support for changing the IP address related parameters via the drive s keypad only applies to G9 drives with V203r5 or later control board firmware or H9 drives with V204r4 or later control board firmware PROFINET firmware e Nonew PROFINET firmware released at this time current version remains at V2 000 User s manual version e 10639 2 100 000 gt 06 09 2008 ASD interface CPU firmware e 1 200 release e Minor efficiency improvements to communication between ASD interface CPU and network interface CPU gt 04 15 2008 Multiprotocol firmware e 2 000 release e Add Alarm monitoring functionality with email reporting e Add ability to change authentication information config tab e Add ability to change IP address assignments via web page config tab e Add selection for writing drive configuration parameters to just RAM or both RAM and EEPROM config tab e Add Ethernet IP class 1 IO messaging support with associated consumed produced data configuration e Ethernet IP

Download Pdf Manuals