User manual DSU BOX - Pelweckyj Videotechnik GmbH
Contents
1. firmware version can be indicated by clicking options button at parametrization software firmware 14 06 2006 or by i taking a look at label of EPROM located at video matrix mainboard VM _0606_X14 is means to 14 06 2006 Alternatively checksum which is indiacted during video matrix startup can be used for determing firmware ver sion Mentioned firmware equals to checksum 1C04 SIMATRIX SYS 8C12 SIMATRIX 648 or 89F2 SIMATRIX 164 respectively Aluminium housing version of DCU dome converter front view Issue 11 2013 5 11 DSU BOX user manual Aly PELWECKYJ 2 1 Number of Domes DSU module is able to control up to 32 domes on same bus accord ing to RS485 specification It is possible to control up to 16 different domes at same time If more than 32 domes should be controlled physically or domes should be controlled in a star shaped manner a RS485 RS422 mul tiplexer would be required f e type RS485MX16 which provides 16 RS485 outputs or 16 RS422 full duplex ports respectively 3 Setting up for Operation 3 1 Environmental Conditions Comply with the environmental conditions specified by the manufacturer operating temperature 5 C to 45 C relative humidity 30 to 85 non condensing Protect the device from moisture and fluids Do not expose the device to direct thermal radiation e g heating devices Do not operate the device in very dus
2. side of housing to remove top cover of DSU i e four screws in total Remove top cover of DSU Cable of power supply should be passed through feed through hole dismantled and connected to two pole power supply terminal block use a screwdriver to release clamp lever Prior closing and screwing housing perform a short test for function Status LED must blink green Remark LED will be unilluminated if polarity is wrong 3 3 Configuration Some DSU configuration by internal DIP switches is dependent on firmware version Firmware version is printed on label inside DSU three letters Following tables will describe DIP switch function ac cording to firmware version Issue 11 2013 7 11 DSU BOX user manual NCS SivisMiniDome Switch Switch setting off Switch setting on S1 Video matrix baudrate 2400 Baud S2 Video matrix baudrate 4800 Baud S3 Video matrix baudrate 9600 Baud S4 Dome baudrate 9600 Baud Dome baudrate 19200 Baud S5 Dome parity None 8N1 Dome parity Even 8E1 S6 Switch must be set to on S7 Terminal filter active Terminal filter inactive S8 reserved reserved NRA SpeedDome Ultra CCDA14x5 Switch Switch setting off Switch setting on S1 Video matrix baudrate 2400 Baud S2 Video matrix baudrate 4800 Baud S3 Video matrix baudrate 9600 Baud S4 Dome baudrat
3. PELWECKYJ VIDEOTECHNIK GmbH DSU BOX DSU dome converter TTY RS422 housing version User manual issue 11 2013 DSU BOX user manual j yy 1 Safety Before starting up operation maintaining transporting or storing this product read the safety advices for this product as well as the entire instruction Pay attention to the warning notices in the succeeding chapters Keep this document for later use or for handing it over together with the product In addition regard the local safety standards or laws for planning installation operation and proper disposal of the product 1 1 Symbol Meaning A Dangerous situation i Useful information 1 2 Meaning of Precautionary Statements The seriousness of a hazard is expressed by the chosen signal word Following signal words will be used in case of an appropriate hazard Signal word Meaning Danger Indicates a hazardous situation which if not avoided will result in death or serious injury Warning Indicates a hazardous situation which if not avoided could result in death or serious injury Caution Indicates a hazardous situation which if not avoided could result in minor or moderate injury Issue 11 2013 2 11 DSU BOX user manual i yy 1 3 Authorized Persons Warning Danger of life for persons without necessary qualification gt Only skilled personnel are allo
4. Position 72 Patrol save Table of menu functios partially only available if camera menu was activated Control SivisMiniDome SpeedDome Ultra VI Pelco Domes JVC Domes unit key or CCDA14x5 Protocol JCBP S Joystick or Move cursor in menu Move cursor in menu Move cursor in Move cursor in me Arrow keys menu nu Zoom Tele Enter Zoom Wide Back Focus Near Sub menu Sub menu K500 OSD Activate camera menu Activate camera Activate camera Activate Deactivate menu menu camera menu K500 SET Menu enter Menu enter Menu enter Menu enter K500 up Menu up Menu up Menu up Menu up K500 down Menu down Menu down Menu down Menu down K500 color Colour Colour Colour Colour K500 B W_ Black white Black white Black white Black white Init Reset Reset Issue 11 2013 9 11 DSU BOX user manual Ally PELWECKYJ 5 Pin assignment of DSU DSU BOX provides two 9 pole D Sub connectors a TTY input and RS422 output RS422 output connector and connection status LED are located at front side of DSU Power supple cable feed through 12V 200mA and TTY input con nector are located on back side of DSU Pinning TTY input 9 pole D Sub male connector Pin Port 1 2 3 RX 4 RX 5 6 GND 7 12V 8 9 Pinning RS422 output 9 pole D Sub female connector Pin Port 1 RS422 TX 2 3
5. RS422 TX 4 5 6 7 8 9 6 Maintenance 6 1 Cleaning For cleaning use only a clean dry cloth Do not use liquid cleaning agents or spray Issue 11 2013 10 11 DSU BOX user manual Aly PELWECKYJ 7 Transport and Storage Keep the original device packaging for later transports Do not expose the device to mechanical shocks Issued by Pelweckyj Videotechnik GmbH GiterstraBe 2 64807 Dieburg Germany info pelweckyj de Issue 11 2013 11 11
6. U must match to terminal baudrate of video matrix E Terminal filter must be set to on if DSU is operated at Simatrix 164 168 or 648 Issue 11 2013 8 11 DSU BOX user manual 4 Camera specific functions of DSU Dome functions for which no standard key of control unit is assigned can be accessed via position preset commands instead Used posi tion presets are not further available i e only position presets 1 60 and 73 99 are available if supported by dome Table of special functions Control SivisMiniDome SpeedDome Ultra VI Pelco Domes JVC Dome unit key or CCDA14x5 Protocol JCBP S Position 61 Activate camera menu Activate camera menu Activate camera Activate camera menu menu Position 62 Deactivate camera Deactivate camera Deactivate camera Deactivate camera menu menu menu menu Position 63 Autofocus Autofocus Autofocus Autofocus Position 64 Startposition home Startposition home Startposition home Startposition home position position position position Position 65 Colour Colour black white IR cut filter on day Position 66 black white IR cut filter off night Position 67 Patrol start Patrol start Patrol start Position 68 Patrol stop Patrol stop Patrol stop Position 69 Patrol learn Patrol learn Patrol learn Position 70 Reset dome Reset dome Stop scan Position 71 Patrol test
7. e 9600 Baud Dome baudrate 19200 Baud S5 Menu control via pos commands Menu control via pos commands Pos 60 72 according to table of chapter 5 Pos commands would be sended transpar ently refer to dome manual S6 Switch must be set to on S7 Terminal filter active Terminal filter inactive S8 Varispeed characteristic matched to Varispeed characteristic matched to SpeedDome Ultra RAS816 CCDA1425 CCDA1435 NPE Protocol Pelco D several dome types Switch Switch setting off Switch setting on S1 Video matrix baudrate 2400 Baud S2 Video matrix baudrate 4800 Baud S3 Video matrix baudrate 9600 Baud S4 Dome baudrate 9600 Baud Dome baudrate 19200 Baud 5 Varispeed characteristic Varispeed characteristic linear optimiert for SpeedDome 2 S6 Switch must be set to on S7 Terminal filter active Terminal filter inactive S8 Reserved reserved NJV JVC Dome Protocol JCBP S Switch Switch setting off Switch setting on S1 Video matrix baudrate 2400 Baud S2 Video matrix baudrate 4800 Baud S3 Video matrix baudrate 9600 Baud S4 Dome baudrate 9600 Baud Dome baudrate 19200 Baud S5 Dome parity None 8N1 Dome parity Even 8E1 S6 Switch must be set to on S7 Terminal filter active Terminal filter inactive S8 reserved reserved Remarks m Video matrix baudrate setting of DS
8. ty environments Do not operate the device in the neighbourhood of a strong source of electromagnetic waves Do not expose the device to mechanical shocks If DSU controls domes which are located outside the building where video matrix is installed a lightning protection coarse protection is required at control lines Control lines which are installed at rough electrical in parallel to ac power lines conditions have to be equipped with a surge protection f e Phoenix before connecting to DSU DSU complies to requirements for surge according to EN 61000 4 5 class 2 and requirements for burst according to EN 61000 4 4 test level 2 Issue 11 2013 6 11 DSU BOX user manual Ally PELWECKYJ 3 2 Installation Connect DSU module TTY input to unused Terminal connector of SIMATRIX video matrix by using a 1 1 direct connection cable male female maximum length 5m DSU will be supplied with power from video matrix via this cable Do not connect an additional external power supply to DSU If distance between DSU and video matrix is greater than 5m power has to be supplied by an external power supply 12V 200mA not part of the delivery available on request Only Pin 3 and 4 of TTY input must be used in this case not pin 6 and 7 cable length up to 1200m Connecting an external power supply to DSU Disconnect all plugs from DSU Unscrew two upper screws on each
9. wed to work on the device gt Disregarding this can cause death serious injury or consider able property damage This document does exclusively address the following target audi ence installer maintainer Qualification Function Has expert knowledge in the field of Set up the product electric installations and knows elec trical hazards of any kind Maintain the produet Dismantle the product Comply with the appropriate safety regulations for low voltage sys tems especially general safety and installation regulations 1 4 Device specific Advices A Warning Proper and safe functioning of the device depends on appropriate transport storage installation and on accurate operation and maintenance Use only the power supply recommended by the manufacturer Danger of life by electric shock The interior of the power supply contains energized conductors gt Do not open the power supply gt Disregarding this can cause death serious injury or consider able property damage Comply with the environmental conditions specified by the manufacturer Issue 11 2013 3 11 DSU BOX user manual j yy Modifications of the device are only allowed as far as they are mentioned in this document or explicitly allowed by the manufacturer Use only spare parts and accessories approved by the manufacturer The device may only be operated when dr
10. y and undamaged High temperature variations can cause accumulation of moisture inside the device e g after transport Power on the device only after the temperature of the device is adapted to room ambient temperature Only use wall plug adapters or wall power supplies complying with local permissions or regulations Electrostatic Discharge Electrostatic discharge can damage or destroy components gt Do not touch parts at risk e g contacts of plugs gt Before touching a device discharge your body electrostatically e g by touching a grounded metallic object Issue 11 2013 4 11 DSU BOX user manual PELWECKYJ VIDEOTECHNIK GmbH 2 Introduction DSU module transfers video matrix Siemens SCU protocol of TTY interface to one dome protocol which is provided at output port RS485 TX only or RS422 full duplex reverse channel will not be used respectively According to firmware version DSU is able to control dome cameras of several manufactures by using their specific communication proto col one protocol per each firmware version This manual is indented for DSU hardware version 08 and following firmware versions CCDA14x5 or SpeedDome Ultra NRA SivisMiniDome NCS Pelco D protocol several types NPE JVC Dome Protocol JCBP S NJV Using DSU connected to a Simatrix SYS 648 or 164 requires video matrix firm ware version from date 14 06 2006 Actual