Home
Manual
Contents
1. RH 10 to 60 C 14 to 140 F 10 to 75 RH 240 L x 68 W 25 H mm 210g including battery 9V battery carrying case screwdriver instruction manual windscreen 3 5mm plug NOMENCLATURE AND FUNCTIONS Microphone 1 2 inch Electret Condenser microphone Display Serves to display the sound pressure level dB over or under range OVER maximum hold data MAX HOLD and Low battery indicator BT dB Sound pressure level with 0 1dB resolution OVER Shown when the range setting is too high or low 6 DVM1351 SOUND LEVEL METER Power and Range switch Turn power ON and select measurement range Hi range 75 130dB Lo range 35 90dB When OVER is indicated slide range switch to another range for measurement Response and Max hold switch Setting the meter dynamic characteristics Fast slow and maximum value hold S slow response for comparatively stable noise measurement F fast response for fast varying noise MAX HOLD the max hold position is used to measure the maximum level of sounds The maximum measured level is continuously updated To re fresh please set switch to F or S position to cancel existing value then set switch to MAX HOLD position Function switch A C weighting amp calibration selector A A weighting C C weighting CAL 94dB Calibration Calibration control can be adjusted clockwise or anticlockwise to standard 94 0dB Rese
2. SOUND LEVEL METER Avellemen components DVM1351 RANGE BESPOHSE 4 i a4 FEDER bie Lomas soem Hi a f e 13048 IEG 51 AKSI 81 4 TYPE ACCURACY 1 5a8 cE INSTRUCTION MANUAL HANDLEIDING MANUEL D UTILISATEUR SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter Use the meter only as specified in this manual otherwise the protection provided by the meter may be impaired Environment conditions Altitude up to 2000 meters Relatively humidity 90 max Operating Ambient 0 40 C Maintenance amp Cleaning Repairs or servicing not covered in this manual should only be performed by qualified personnel Periodically wipe the case with a dry cloth Do not use abrasives or solvents on this instrument Safety symbols Meter is protected throughout by double insulation or reinforced insulation Complies with EMC 2 DVM1351 SOUND LEVEL METER GENERAL DESCRIPTION AND FEATURES Thanks you for selecting our Sound Level Meter To ensure that you get the most from it we recommend that you read and follow the manual carefully before use This unit conforms to the IEC651 type2 ANSI S1 4 Type2 for Sound Level Meters The Sound Level Meter has been designed to meet the measurement requirements for industrial safety offices and sound quality control in various environments Rang
3. battery cover on the back and insert one 9V battery Note make sure the battery polarity is correct 2 Battery Replacement When the battery voltage drops below the operating voltage BT will appear on the display and the battery should be replaced with a new one OPERATING PRECAUTIONS 1 Wind blowing across the microphone will bring additional extraneous noise Once using the instrument in the presence of wind the windscreen must be mounted in order not to pick up undesirable signals 2 Calibrate the instrument before operation if the instrument has not been in use for a long time or has been operated in a bad environment 3 Do not store or operate the instrument at high temperature and in a humid environment for a long period 4 Keep microphone dry and avoid severe vibration 5 Please take out the battery and keep the instrument in a low humidity environment when not in use 10 DVM1351 SOUND LEVEL METER MEASUREMENT 1 Open battery cover and install a 9 Volt battery in the battery compartment 2 Turn on power and select the desired response and weighting If the sound source consists of short bursts or only catching sound peak set RESPONSE to FAST To measure average sound level use the slow setting Select A weighting for a general noise sound level and C weighting for measuring the sound level of acoustic material 3 Hold the instrument comfortably in the hand or fix it on a tripod and point
4. es from 35dB to 130dB at frequencies between 31 5Hz and 8KHz Display with 0 1 dB steps on a 4 digits LCD With two weighting A and C Both AC and DC signals output is available from a single standard 3 5mm coaxial socket suitable for a frequency analyser level recorder FFT analyser graphic recorder etc DVM1351 SOUND LEVEL METER SPECIFICATIONS Standard applied Frequency range Measuring level range Frequency weighting Microphone Display Digital display Time weighting Level ranges Accuracy Dynamic range Alarm function Maximum hold Calibration 4 DVM1351 SOUND LEVEL METER IEC651 Type2 ANSI SI 4 Type2 31 5Hz 8KHz 35 130dB A C 1 2 inch Electret condenser microphone LCD 4 digits Resolution 0 1dB Display period 0 5 sec FAST 1 25mS SLOW 1 sec Lo 35 90dB and Hi 75 130dB 1 5dB under reference conditions 55dB OVER is show when input is out of range Hold readings with decay lt 1 dB 3 minutes Electrical calibration with the internal oscillator 1 KHz sine wave AC output DC output Power supply Power life Operating temperature Operating humidity Storage temperature Storage humidity Dimensions Weight Accessories DVM1351 SOUND LEVEL METER 0 65 Vrms at FS full scale output impedance approx 600Q 10mV dB output impedance approx 100Q One 9V battery About 50hrs alkaline cell 0 to 40 C 32 to 104 F 10 to 90
5. t button Serves to reset the maximum level indication Output jack Standard 3 5mm 3 pole coaxial output socket Serves to supply AC signals and log converted DC signals to external equipment DVM1351 SOUND LEVEL METER OUTPUTS Two outputs can be accessed through 3 5mm stereo phone plug refer DC output Logarithmic signal 10mV dB Impedance lt 100Q AC output approx 0 65Vrms corresponding to each range step Impedance 600Q DC OUTPUT AC OUTPUT GROUND Battery cover on bottom LCD DISPLAY DESCRIPTION Sound Pressure Level measuring value resolution 0 1dB Measuring unit When readout is out of range MAX HOLD Maximum hold BT Low battery indicator 8 DVM1351 SOUND LEVEL METER CALIBRATION PROCEDURES 1 Using an acoustic calibrator a Make the following switch settings RANGE Hi RESPONSE F FUNCT A b Put the microphone carefully into the insertion hole of the calibrator Turn on the switch of calibrator and adjust the CAL screw of the instrument until the level display indicates the desired level C N Note Our products are well calibrated before shipment Recommended calibrator cycle is one year 2 Calibration using the internal oscillator a Make the following switch settings RANGE Hi RESPONSE F FUNCT A b Adjust the unit to the readout DVM1351 SOUND LEVEL METER MEASUREMENT PREPARATION 1 Battery Loading Remove the
6. the microphone at the suspected noise source the sound pressure level will be displayed 4 When MAX HOLD mode is chosen the instrument captures and holds the maximum noise level for a long period Press RESET button to reset the maximum level indication 5 Turn OFF the instrument when not in use DVM1351 SOUND LEVEL METER 11