Home
PEDICURE SPA USER MANUAL
Contents
1. Pioneering Smart Pedi Spas PEDICURE SPA USER MANUAL VERSAS Before Operating the unit please read this manual thoroughly and retain it for future reference RECEIVING AND INSPECTION PLEASE TAKE NOTE Thoroughly inspect each shipment immediately upon arrival It is important that you notify the driver and insist on a notation of the damage Make this notation directly on the freight company s waybill or bill of lading Failure to note damage on the waybill or bill of lading may impede and or prevent any claims that you may have against the freight carrier If missing parts or damage is found Please notify the carrier at once and request an inspection DO NOT DISCARD THE SHIPPING BOX If you give the carrier a clear receipt for goods that have been damaged in transit you do so at your own risk and expense TRADEMARK DISCLAIMER V Spa Elite Platinum Mystique Versas Vista Elite Ultra Q Spa Sani Drain PureFlo Pioneering SMART Pedi Spa Auto Fill AutoClean and TT350 and Tru Touch are the registered trademarks of Lexor Inc Reproduction or reuse of part or all of trademarks are expressly prohibited without written permission from Lexor Inc Due to limitation of the printing process product colors shown might look different from actual colors Lexor will not be responsible for any misprint of this advertisement Lexor s footspa specification and prices may change without prior notice Pedicure Spas are intended for
2. professional used only always follow your State Board s sanitation and disinfectant guideline Table of Contents RECEIVING AND INSPEQCTION erm 1 SAFETY aad cp mk OBI bao ne E eU 3 PARTS Identifying Parts for Versas Model 4 INSTALLATION opa to Spa Recommended 5 Wall SP Tcl ec or RT 5 Manicure Tray Armrest Back Rest Installation 6 DOWN SWINGING ATITIEBS tdeo 6 7 FUMON GODPeellofS 2 E TE 8 FOWer D AIN naa a E E D 8 Gravity Dran Under GEOBd s b a E EE 9 Plumbing Flow Pattern for Power Drain eese 9 Plumbing Flow Pattern for Gravity 10 Hot And Cold Water Supply LINES 10 SPA SPECIFICATION Electrical and Pedicure Spa Component Specification 12 OPERATION AND CARE Operation and Care Instructions 13 Manual Operation For Non Auto Fill V Drain Models 13 EAE E E 13 OOM 13 DAINO 13 AUTO E 14 cost
3. UNLESS THEY ARE CLOSELY SUPPERVISED AT ALL TIME e LIRE LES INSTRUCTION DU FABRICANT AVANT DE METTRE EN MARCHE e UTILISER SEULEMENT A L INTERIEUR e COUPER LE COURANT AVANT DE PROCEDRE AU DEPANNAGE AU NETTOYAGE Warning 4 Excessive water temperature is dangerous and should be checked BEFORE use 2 Maximum temperature of the water should never exceed 100 degrees F 3 DO NOT STEP STAND IN FOOT BASIN 4 Always enter and exit the Pedicure Spa slowly and carefully 5 NEVER bring and or operate any electrical devices into or near the Pedicure Spa 6 Maximum load in spa chair is 250lbs 114kg Warning If a crack in the GLASS BOWL occurs DO NOT handle unless the proper attire and equipment is used Discontinue use of the bowl until proper equipment is replaced You may be held accountable for any injury that may occur Lexor Inc is not liable for any injury that may occur STATES NOTICE In the common wealth of most of the States all pedicure spas shall be installed for Commercial usage in the states are required to have backflow preventer This equipment shall be installed between the water inlets and the spa at Salon s cost ND CON O CO PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE Identifying Parts for Versas Model Pedicure Whirlpool with Massage System Identifying Parts Head Rest Chair Cushion with Massage Armrest Cushion Massage Remote Control Manicure Tray Optio
4. spa basin must be wiped dry with a clean towel At the End of Each Day 1 The screen shall be removed all debris trapped behind the screen shall be removed and the screen and the inlet shall be washed with soap or detergent and water 2 Before replacing the screen the screen shall be totally immersed in an EPA registered disinfected with demonstrated bactericidal fungicidal and virucidal activity which must be used according to the manufacturer s instructions 3 The spa system shall be flushed with low sudding soap and warm for at least 10 minutes after which the spa shall be rinsed and drained At Least Once A Week 1 The spa basin shall be filled completely with warm water and 1 teaspoon of 5 2596 bleach for each gallon of water or a solution of Sodium Hypochlorite of approximately 50ppm used according to manufacturer s instructions 2 he spa system shall be flushed with the bleach and water solution or Sodium Hypochlorite solution for 5 10 minutes and allowed to sit for 6 10 hours 3 The spa system shall be drained and flushed with water before use upon a patron 20 WARNING FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY AND OR WARRANTY WILL BE NULL YOU MUST HAVE A QUALIFIED LICENSED PLUMBER TO CONNECT THE SPA IN PLACE SAFELY UL SAFETY RECOGNIZED FOR UNITED STATES AND CANADA PROPER INSTALLATION ACCORDING TO THIS MANUAL IS REQUIRED 2012 All Rights reserved Design and Specifications are subject to change wit
5. E E 14 Jet Cover Removal amp 1 6 ienai 16 Jet Housing Removal amp Installation cccccccecccseceeseeeeeeeeseeeeseeeeseusesseeeseeeseeeeseees 17 Massage System amp Remote 18 Top massage Chair Basic Installation ccccce cece eeeeeeeeeeeeeeseeeesaeeeeanenas 19 Safety Requirements for Pedicure 20 Safety Precautions Precautions READ AND FOLLOW INSTRUCTIONS CAREFULLY SAFETY PRECAUTIONS LAN wamne THIS PRODUCT IS FOR INDOOR USE ONLY DISCONNECT POWER SUPPLY CORD BEFORE SERVICING This product is to be connected to a branch circuit outlet protected by a Class A GROUND FAULT CIRCUIT INTERRUPTER GFCI and the GFCI shall be tested regularly for continued protection and correct operation If a Class A GFCI protected outlet is not available DO NOT USE THIS PRODUCT Please contact a licensed electrician for installation of a Class A GFCI according to local electric codes or equivalent A Warning DO NOT USE if you are diabetic have poor circulation or if any area of your feet or legs is inflamed or has an open sore Consult your physician before using if you have any kind of fungal infection swelling fracture or persistent pain LAN wring TO REDUCE RISK OF INJURY DO NOT PERMIT CHILDREN TO USE THIS UNIT
6. Flow Pattern for Gravity Drain Lexar Pedicure Spa Plumbing Flow Parttern Gravity Drain Hat cald water inlet Back Flcw Preventer Mot lincluded 1 14 Flex Hase Wi Removable Connection Under ground To Sanitary Plumbing Is responsible for under ground wastewater treabment system based on ihe ANSI Standard ATT 1 2003 Comm 81 B HOT AND COLD WATER SUPPLY LINES Carefully connect 2 ID supply hoses not provided to fresh water sources Shut off valves not provided should be utilized Valves should be placed outside the tub for easy access Before water line connections please follow below Determine if your spa chair is used for a new construction of a salon or a replacement spa chair 1 New construction Make sure to remove any and all debris and or dust from current hot cold water pipes before hooking up to spa Suggested direction to remove debris turn on water and drain into a bucket or container See illustration below 2 Replacement Spa Always use new hot cold water hoses when connecting a new spa chair to prevent debris such as old rubber particles from clogging drain 10 Installation CONNECT DRAIN WITH POWER DRAIN PUMP OR GRAVITY DRAIN NO PUMP Using 34 schedule 40 PVC Power Drain or 1 14 flex tube Gravity Drain and appropriate traps Connect drain to meet local plumbing codes Rubber connection to the drain should be removable for easy service and should not be permanent to prev
7. e water line air gap is accommodated with back flow prevention required by plumbing code e Depending on pedicure spa model arms may swing open swing up down or slide forward backward PECIFICATIONS Spa Dimensions amp Weights All Spa seat up right L 51 52 129 132cm Versas amp model Length 50 127cm Wz31 79cm w Tray 45 46 114 116cm H 56 1 42cm Clearance of 18 20 32cm needed for recline Empty Weight 200 Ibs Shipping Weight 260 165 Pedicure Stool 12 13 Manicure Stool 16 25 20 Spa Water Capacity 5 US Gallon Jet Motor 120 VAC at 85W 60Hz Massage Motors Seat Sliding amp Reclining 24VDC 2 5Ax5 Discharge Pump Motor 120 at 85W 60 Hz Maximum vertical lift 3ft Flow rate 500 GPH floor level Power source 115 VAC 60HZ Power needed per spa chair 6 Amp One 1 electro mechanical knob for the Whirlpool Rated at 5A contact Electrical Switches One 1 electro mechanical knob for the Drain Rated at 5A contact Installation should be made with connection at the external interface parts Please consult with your local plumber Safety Versas Pedicure Spa is UL listed 12 Plug amp Play Installation Operation and Care OPERATION AND CARE INSTRUCTIONS Manual Operation For Non Auto Fill Drain Models Filling Close the Drain Stopper by turning the Drain Knob counterclockwise Utilizing the single lever hot cold mixer faucet loca
8. ent damages Wall m m JA to 1 1 2 T connector NV To Main Drain Tub Check Valve amp y Detail A 11 Spa Specifications ELECTRICAL AND PEDICURE SPA COMPONENT SPECIFICATIONS All electrical connections MUST be made by a qualified licensed electrician in accordance with Local amp National Electrical and Building Codes A 110V 50 60 Hz 15 Amp GFCI protected grounded circuit MUST be used to supply power to the Pedicure Spa A dedicated circuit must be used with a GFCI All wiring must conform to National amp Local Electrical Codes IT IS EXTREMELY IMPORTANT THAT THE FOOT SPA OPERATES WITH GFCI PROTECTION VERY IMPORTANT Both back of chair and seat are adjustable When both are at maximum positions one must allow 18 44cm from back wall to foot spa This minimum distance assures unobstructed recline Failure to follow this required dimension might damage your spa components and plumbing connections which will void your warranty PEDICURE SPA SPECIFICATIONS e Construction Marble composite high gloss acetone proof gel coat Two 2 electro mechanical knobs control the drain and whirlpool Electro mechanically operated reclining massaging and sliding seat with hand held control One 1 pipe less whirlpool jet Pipe free technology Power drain or Gravity drain Extendable water spray positioned well abov
9. hout notice 21
10. igned for overflow protection in case of an emergency Jf water flow rate is too weak due to current plumbing you may notice the water stops before reaching water sensor This is because the 3 minute time out has been activated To continue filling turn the Auto Fill knob clockwise Must scrub and clean water sensors frequently to ensure that water stops right at sensor level If necessary clean using sponge buffer Manual conversion Auto Fill option can be simply reset to normal manual mode as a contingent system when automatic operation becomes unavailable Please call our Customer care for step by step instructions Panel Functional Switches amp Operating Instructions Hot Cold water faucet located at the center of the front panel 1 1 Use faucet knob to adjust optimal water temperature at H Left or C Right directory 1 2 Pull out and tilt down faucet knob to shut off water any time during the automatic or manual operational cycle Drain Knob ___ A ___Auto Fill Jet Knob Water Control Knob Hot Cold N wearin Must be used when spa chair is left unattended or for overnight procedures to shut off water supply to basin Water Control Knob Pull out knob in direcion of arrow Tilt down knob to shut off water 14 Operation and Care and Care Auto Fill Jet Switch Dual functional momentary switch located on the right side of the front panel 1 Totu
11. nal Tub Bowl Footrest Sani Drain System with Discharge On Off Knob 9 Hot Cold Water Mixer Valve 10 Dual Function Auto Fill amp Jet On Off Knob Upgrade Option Only 11 Flex Water Filler Spray opout 12 Up Down Armrest Tub Light Drain Stopper Pure Flo Jet Handbag Purse Hook Optional High Profile Stool for Manicure Optional Installation SPA to SPA RECOMMENDED CLEARANCE MANICURE TRAY ARMREST BACK REST INSTALLATION Up Down Swinging Armrest Arm Rest Cushion Manicure tray Purse Hook 1 Plug In the manicure trays and attach the purse hook 1 Supplied Installation BACK REST 1 To set backrest up Lift up the backrest until a Click is heard Make sure the lever is locked before operating 2 To fold down backrest Lift up lever handle located on the left side bottom of Chair Installation Plumbing Connections Warning Before any connection pay attention to these subjects 1 Debris or residue may become lodged into the Hot and Cold hoses during construction which may clog the Hot and Cold Mixer To clean drain a good amount of water from water hoses to bucket before connecting them to the pedicure spa Failure to do so may void your Warranty 2 Hooking up a used Hot Cold flex hose is not recommended since debris from broken rubber seal might clog water mixer Failure to do so may void your Warranty 3 Backflow preve
12. nter Due to differences in construction lay out of your Salon and City s plumbing code please contact your local Plumber to fulfill your needs as required Backflow Preventers are not supplied by the pedicure spa manufacturer 4 Check valve is an optional part and supplied free of charge for your convenience Factory is not liable for this Check valve 5 Maximum Inlet water pressure must be under 75 PSI Power Drain 34 PVC Drain 17 1 2 ID Cold Water 9 4 1 2 ID Hot Water 4 1 X r oY __26 oe AC 3 4 Check Valve See Installation Instruction attached with supplied Check Valve Installation Gravity Drain Under Ground 11 2 pipe 1 1 4 pipe 1 2 ID Cold Water 777 4 2 ID Hot Water Plumbing Flow Pattern for Power Drain Lexor Pedicure Spa Plumbing Flow Parttern Power Drain Hoticold water inlet Back Flow Prevenber Mot Included Ootlonal as required by Local Clty Plumbing Code Drain pump sies detail All Draln plolng from check Valve to wall and behind wall not Included To be connected to an Indirect Waste Connector HH Hot Cold Valves must be located outside of HA spa where they can be easily accessed detail Local plumbing is responsible from check valve to wall for wastewater treatment system according to Local Plumbing Code Malin Line Installation Plumbing
13. rn water on Turn knob clockwise for 1 second and release Water will fill up to reach the sensor level and activate the whirlpool jets to proceed a running duration of thirty 30 minutes automatically 2 To turn water off Turn knob clockwise for 1 second and release to turn off water The switch can be activated to turn on or turn off water any time during the Auto Fill cycle EXCEPT when water is at sensor level To turn Off the whirlpool jet Turn knob clockwise for 1 second and release This Jet cannot be turned on if water level is not at sensor level Drain Switch Dual Action Electro mechanical Switch located on the left side of the front panel When activating the switch it will raise the drain stopper and power up the drain pump if exist at the same time 3 1 To drain water Turn the drain knob clockwise Switch is activated 3 2 To turn off the drain pump Turn the drain knob counterclockwise 15 Jet Cover amp Impeller Cover amp Impeller JET COVER REMOVAL amp INSTALLATION 1 Turn Counterclockwise to remove Turn Clockwise to install Motor amp Housing Impeller Jet Cover Jet Cover amp Impeller JET HOUSING REMOVAL amp INSTALLATION 1 Turn clockwise to remove motor Turn counterclockwise to install motor 17 Operation and Care MASSAGE SYSTEM amp REMOTE CONTROLLER 1 Press Auto Button to start Auto mode Press again to turn off massage Auto and Manual mode
14. s for cleaning requirements Overnight soaking with overdosed Chlorine may damage rubber part in basin CLEANING PROCEDURE IS REQUIRED BY STATE BOARDS Note A cleaning log should be kept with each pedicure spa Each State will have slight differences in cleaning policies please check with your state s Bureau of Barbering and Cosmetology or Regulatory Authority for specific details Safety Requirements for Pedicure Spas The Bureau of Barbering and Cosmetology requires that salons using whirlpool pedicure foot spas must follow these disinfecting procedures to ensure proper cleaning and maintenance of the equipment and to prevent the spread of bacterial or parasitic disease Violation of this section may result on an administrative fine and or disciplinary action Each foot spa that is not in compliance with this section may result in a separate violation NOTE Authority cited Section 7312 Business and Profession Code Reference Section 7312 e Business and Professsion Code Below is a suggestion for your pedicure spa chair s cleaning procedure After Each Customer All water shall be drained and all debris shall be removed from the spa basin 2 he spa basin must be cleaned with soap or detergent and water 3 The spa basin must be disinfected with an EPA registered disinfectant with demonstrated bactericidal fungicidal and virucidal activity which must be used according to manufacturer s instructions 4 The
15. ted on the front of the Pedicure Spa fill the tub to the water level above the whirlpool jet at least 1 inch You must completely submerge the jet If during the operation of the whirlpool the water level decreases simply add more water Whirlpool Starting Turn the Jet Knob located on the right side of the front panel to clockwise to turn on Turn counterclockwise to shut off Do NOT turn ON the WHIRLPOOL JET unless adequate water is in the tub Draining Turn the Drain Knob clockwise to open the Drain Stopper Power Drain will turn on automatically if drain pump exist Do NOT turn ON the DRAIN PUMP unless adequate water is in the tub THE WARRANTY IS VOID IF THE PUMP HAS BEEN RUNNING DRY NOTE Whirlpool action can cause even small amounts of soap or body oil to foam excessively For this reason refrain from using these products during the whirlpool cycle Jet Knob Water Control Knob Hot Cold 13 Operation and Care Auto Operation Auto Fill Models Upgraded Automatic Auto Fill cycle Water will automatically turn off when optimal water level is detected by 2 sensors It is followed with the immediate start of Whirlpool jet for a duty cycle of thirty 80 minutes The Auto Fill cycle is safely protected by 2 sensors 3 minute time out and can be extended with a manually operative shut off valve located at the front panel Please note The 3 minute time out is des
16. will run for duration of 20min 2 Press any button Rolling Spot Kneading Tapping Combine to enter Manual mode 3 Press Rolling Spot to start rolling up down and stop at desired spot 4 Press Intensity button to select tapping intensity 5 Vibro Button LED is an option Pressing this button will resume with Tapping action 6 Press any chair button Recline Incline Backward Forward to move the chair to desired positions 18 Operation and Care NOTE If the Massage Chair is not provided then the end user will need to install a UL listed and cUL CSA certified massage chair with a suitable Class 2 Power Supply TOP MASSAGE CHAIR BASIC INSTALLATION INSTRUCTIONS aya ET Drill 4 mounting holes 17 Width216 5 Length 11 Install seat frame and secure 4 screws from bottom base Using the provided stand off to adjust the height of seat frame as needed to allow seat frame to travel freely Lift up back massage to engage locking device Manually adjust actuator rod to lock as needed Install back cushions Plug AC cord to power strip Located inside of the tub base Install seat cushion with 2 screw knobs Level the back massage and secure 2 hinge screws onto the metal brackets Do not turn the screw all the way in Leave thread screw head for sliding Install back shell with 4 screws as Fig 3 Controller PCB 19 A WARNING vou must always refer to your state or local guideline
Download Pdf Manuals
Related Search
Related Contents
Samsung SC-152G manual do usuário Mobile Tennis Scorer plus Statistics User Manual Dataflex CPU Protection Case 2 Fans 729 Canon PC800S Camcorder User Manual Istruzioni per l`uso Navini Networks 40-00292-00 User's Manual ILWIS 3.6 Open GEONETCast Toolbox Plug-in User Manual manuale infusore SP InfoCity3D User's Manual NVRPOE Series 1080P NVRs Plug and Play! - Tri Copyright © All rights reserved.