1. Bug fix MVS 180 Corrected ABEND in DF052X if job dataset isn t accessible Bug fix MVS 128 Corrected computing of data set size in DFO94A Bug fix MVS 178 If a data set cannot be created the EERP is suppressed in case of OFTP 1 4 or 2 0 a NERP is send Bug fix MVS 183 Corrected OFTP2 data underflow during decompression CRYPTLIB Be sure to set parameter FIRSTLVL of CNTL member as mentioned above to avoid allocation error for temporary data sets New blueprint for temporary data sets name T Mxx Dyyddd Thhmmss Cxxxx Cyyyy with name taken from parameter FIRSTLV in CNTL Mxx monitor number Dyyddd date stamp Thhmmss time stamp Cxxxx Cyyyy unique counter since monitor start As the allocation for received datasets is done on the temporary dataset name Last changes at 27 11 15 T Systems gedas deutschland GmbH Changes T Systems page 6 of 21 usage of SMS ACS rules for received data sets may conflict with the new blueprint We provide patch_df139d04 on demand to switch back to the old blueprint for temporary data sets designated data set name with time stamp appended thus enabling the ACS rules designed for the designated dataset name to work on the temporary data set name as before Rel 5 03 Level 00 15 11 13 New MVS 141 and MVS 145 rvsMVS supports RACF managed cryptographic keys hardware protected and clear keys MVS 166 New license is required for the ne
2. Bug fixing Display of velocity on transmission of big files corrected Bug fixing serializing creation of send jobs improved Corrects problem with assigning same timestamp queuing time for multiple send jobs Bug fixing serializing receiving of GDG datasets corrected Rel 4 06 Level 00 03 07 08 Bug fixing command DD EERP corrected IN284073 DF052A Bug fixing serialize FTP transmissions IN294289 DFO88F Disable check of double OID DF022B DF052A Bug fixing license keys with year gt 2009 are useable now DF018A DF130B00 Bug fixing RVSDYN Macro corrected DFO66B Improvement Job data sets for RRE are opened and closed in RDS task DF052X DF052X DF058A ERNO 17 Improvement Message DF5820I count CNT is expanded to 5 digits ERNO 54 Improvement ISPF panel display of transmissions for received data sets shows in details if a RRE was used ERNO 62 Bug fixing Message DF9206E corrected DF093C ERNO 40 Bug fixing check for duplicate file and GDG dataset corrected DF119A ERNO 63 Bug fixing rvs user Codes 116 and 120 are unique now New rvs user Codes are 117 and 118 DF117A DF171A DF 178A DF094A ERNO 64 Last changes at 27 11 15 T Systems gedas deutschland GmbH Changes T Systems page 11 of 21 Improvement If you receive in GDG dataset and the ENQ is already used by another task the details of panel entry contain the a
3. DS command Bug fixing wrong allocation of PDSE Bug fixing stop cancel of rvsMVS IN 175066 Bug fixing parameter DSPTI not changeable Reactivation of RMOP after abnormal end new ODETTE codes added licensing by the use of ODETTE id improve job submit DFO078A is obsolete Suitable REXX scripts are added instead of DF078A Rel 4 00 Level 00 14 02 07 XOT implemented Online Encryption implemented New Status EWR End of Transmission and waiting for EERP Status END changed End of Transmission and EERP received Last changes at 27 11 15 T Systems gedas deutschland GmbH Changes T Systems page 13 of 21 New place holders for physical DSN when creating resident receive Entries AR Record New format for timestamp in logfiles Test for valid security key on start of reception of encrypted files Status of interrupted transmissions will be set to END when receiving duplicate file error on restart of transmission Repeat allocating of INTRDR during end of transmission processing if it is temporary not available Shutdown of rvsMVS if license key is not valid during startup Fixed problem 0C4 when using routing and offline encryption Corrected handling in case of timeout during end file don t send a file twice New files on installation CD Rel 3 1 Level 00 14 02 06 SNMP interface implemented Expiration date expanded from nn to
4. Effected module DF125B Improvement MVS 299 Introducing check points for improved diagnostics DF094A DF117A DF119B DF 124A DF058A DFO61A DF029A Improvement MVS 297 Extended and sophisticated OFTP tracing DFO94A DF117A DF119B DF 124A DF058A DFO61A DF130W Improvement MVS 295 rvsMVS can now handle data sets with Format VBS und RECLEN gt 32756 Such data sets are created during transfer of POs Effected modules DF094A and DF119A Improvement MVS 259 Extended diagnostics for allocation problems in DFO61A Receive of PO data sets Last changes at 27 11 15 T Systems gedas deutschland GmbH T Systems Changes page 3 of 21 Bug fix MVS 303 Bug Under certain circumstances ABEND 0C4 may occur during rvsMVS shutdown when using XOT Bug in module DFO95I was fixed Bug fix MVS 302 Bug Under certain circumstances ABEND 0C4 may occur during frequent OFTP2 transfer Bug in module DF052A was fixed Bug fix MVS 301 Bug Changing station parameter FILESIG is not followed by refresh of stations definition in KD Bug was fixed in module DF032A Bug fix MVS 296 Bug Transfer of PO with many members may fail Bug was fixed in module DFO80A Bug fix MVS 277 Bug Under certain circumstances ABEND 0C7 may occur during send Bug in module DFO94A was fixed Bug fix MVS 273 Bug Using TCPIPCHK USERSEP alias USP SID2 in station definition
5. nnnn Avoid a dot at position 44 of dataset name Fixed problem with EERPAD parameter see last known bug in release 3 00 00 Rel 3 0 Level 00 12 12 05 Implementation of User Separation USP see chapter 9 6 in installation manual Added new panel to view transmissions if KD and LOG dataset are in read only mode see user manual chapter 2 7 Added new placeholder for RRE see user manual chapter A 3 Added support for files greater than 2 GByte for encryption compression Corrected problem for large PDSE datasets INC 21974 Corrected problem with zero sized records in variable datasets INC 12461 Corrected problem in ODETTE protocol with zero sized subrecords Known Bug parameter EERPAD doesn t work well the problem will be fixed ASAP Rel 2 5 Level 18 25 04 05 Problem Incorrect timeout handling in the ODETTE task Solution Corrected timeout handling Rel 2 5 Level 17 15 03 05 Last changes at 27 11 15 T Systems gedas deutschland GmbH Changes T Systems page 14 of 21 Problem multiple transmit of the same file in conjunction to message DF5406 Cl INEXCLUSIVE CONTROL BY ANOTHER TASK Solution Corrected rvs monitor Problem Sometimes allocation rename problem in case of RR with replace yes Solution avoid rename in case of RR with replace yes implemented Problem Operator canceled task during restart of a large file which took a lot of tim
6. YES When transfer permissions are switched on ULS YES for a given neighbour station then all transmissions in receive and send direction are restricted Only these transmissions are allowed that are defined in the USER member SN sid member for send and RN sid member for receive in permission dataset For further information see the installation manual Rel 2 5 Level 13 07 05 04 Access to KD dataset from C API Corrected problem with FORMAT TEXT and different translation tables corrected reading of stations table Corrected length of YPREFIX 1 5 characters Corrected problem with BSC line abend C04 Rel 2 5 Level 12 26 03 04 Corrected using of OFTP Compression in case of offline GZIP compression Error in Parameter TCPLOCAD removed Error in Parameter TCPIPADR removed Corrected that in case of SSRM no timeout was available Last changes at 27 11 15 T Systems gedas deutschland GmbH Changes T Systems page 16 of 21 Attribute of DF054K it was changed to non reentrant Added DF079S DF075A00 program is obsolete but for compatibility added again not more supported DF148A program is obsolete but for compatibility added again not more supported Rel 2 5 Level 11 11 02 04 DFO58A Abend 30A at Event start removed DFO95A Problem X25 multi number resolved Rel 2 5 Level 10 02 10 03 27 01 04 PDS data set with LRECL 32760 can be s
7. datasets for decryption compression SECRPREF YPREFIX YSTORCL YMAGMCL YDATACL YPALLOC YSALLOC YUNITC und YUNITN Last changes at 27 11 15 T Systems gedas deutschland GmbH Changes T Systems page 18 of 21 STATIONS member 1 COMPRESS GZIP NO 2 DECRIPTION EXT NO 3 the Parameter PPUKID PPUKNM SPUKID SPUKNM SPRKID and SPRKNM are removed 4 The program DF311G is replaced by function GENKEYS in program DFO54K 5 You can find samples of jobs with the program DF054K in Dataset TABLES The parameter TCPLOCAD CNTL member and TCPIPADR STATIONS member is now up to 60 characters long TSD Problem 56164 Automatic EERP is controlled by the CNTL parameters EERPAD YES NO And the STATION parameter DIALOPT You can use the new command DD EERP TSD Problem 46647 Session Timer for Definite Response after Trailer Record SNA is controlled by Session Timer SESSION Table TSD Problem 78663 QNAME for KEY dataset is KEY RSVK GRS You can switch on the messages DF5233P und DF5207P via command T DISP1 problem 78521 The timeout values in X 25 module are increased Problem 60582 Correction in MSGOUT command for JES2 Problem 65832 Correction for deleting RR fields Panel 5 Problem 78414 Problem 72210 SNA trace dataset not free see documentation update Rel 2 5 Level 05 13 06 02 Corrections of the following errors or problems
8. sessions Up to 8 sessions for remote operating within one monitor may now be established at the same time All messages displayed by the rvs monitor are sent to all active remote operator sessions New feature job start in case of send receive transmission failure The condition of failure to send receive a file can be defined as meeting one of the following criteria The file was not sent received before a specified date and time The file was not sent received because the number of retries exceeded a specified limit See the following parameter descriptions MAXRETRY TRANSHLD ERRJOB ENDDATE and ENDTINE program DFO80A00 Introduction of a new parameter NORELAIS sid to suppress routing to a certain station This function is available only for connections using the ODETTE protocol Last changes at 27 11 15 T Systems gedas deutschland GmbH Changes T Systems page 21 of 21 Last changes at 27 11 15 T Systems gedas deutschland GmbH
9. 08361 Use now dynamic allocation to allocate files for external decryption compression INC 7238 Corrected handling of session number in messages for external decryption compression Rel 2 5 Level 14 26 08 04 Last changes at 27 11 15 T Systems gedas deutschland GmbH Changes T Systems page 15 of 21 Added feature User Level Security ULS Basically User Level Security enables a user to user communication It is provided by two features A user is represented by its own RACF User ID and Odette ID Permissions are applied which files are permitted to be transferred from which sources to which destinations Transfer Permission User related RACF ID and Odette IDs A rvsMVS user represents a user account on the operating system RACF ID Now for every rvsMVS user can be defined an own Odette ID When the user sends a file the source Odette ID that is usually the Odette ID of the local station is replaced by the user s Odette ID Partner stations have to configurate the user s Odette ID as if it would belong to a Odette station that is reached by routing When rvsMVS receives a file for a user s Odette ID rvsMVS delivers the file locally and gives it user s access permissions Transfer Permission Transfer permissions are applied on a per neighbour station base For each neighbour station the appliance of the permissions may be switched on by the station configuration parameter ULS
10. 11 14 Last changes at 27 11 15 T Systems gedas deutschland GmbH Changes T Systems page 5 of 21 New MVS 125 rvsMVS supports EAV New MVS 142 rvsMVS supports multiple private keys and multiple certificates for partner station New MVS 182 Station type MVS is extended by station parameter MVSEXT RETAINU IEBCOPY RETAINU retains the record structure of U datasets IEBCOPY allows transmission of PDS E and PDS using IEBCOPY For IEBCOPY max supported blocksize is 32720 Improvement MVS 174 OFTP2 compression and file signature can be defined as optional allows changing when creating send entry Improvement MVS 154 Creation of unique temporary dataset names improved Parameter FIRSTLVL of CNTL member first level pointer for temporary data sets must be defined and access enabled in RACF Improvement MVS 178 Behavior of rename errors during receive can be controlled by new parameter ONRENERR KEEP SCRATCH Improvement MVS 53 DSN syntax check when receiving a dataset Improvement MVS 177 NERP reason is shown in ISPF panel 2 and 6 Improvement MVS 175 OFTP2 commands CERTIFICATE_DELIVER REQUEST REPLACE are refused if the target is not an OF TP2 station Improvement MVS 121 ComSecure keys If more than one public private key is defined for a station ComSecure will use the valid private key which expires next the valid public key which expires last
11. Changes T Systems a page 1 of 21 Changes rvsMVS 5 Copyright 2015 by T Systems gedas deutschland GmbH Last changes at 27 11 15 T Systems gedas deutschland GmbH Changes T Systems page 2 of 21 Known compatibility issues rvsMVS lt 5 01 00 zOs gt 1 13 S0C1 S0C6 on EERP processing as result of repeated module loading fixed by patch_load_DFO94E 5 00 02 rvsMVS lt 5 00 02 ZOs gt 1 12 S0C4 in DFO18A on startup and DF018C on list CPUID fixed by Patch_rvsMVS_48_DF018 4 00 08 and DF018A 5 00 00 Since rvsMVS version 5 03 00 the using of Language Environment has been changed see TABLES CEEOPTS For detailed information see the installation manual CEEOPTS MSGFILE RVSCMSG FBA 121 0 ENQ RPTOPTS OFF RPTSTG OFF TERMTHDACT UAIMM TRAP ON NOSPIE The Values RPTOPTS and RPTSTG are reporting options If there is a problem you will switch it to ON Important is that the option POSIX OFF is removed Changes rvsMVS Rel 5 04 Level 04 30 11 15 Category Reference Description Change MVS 267 OFTP2 Improvement now available Request e Encryption and compression of empty data sets Change MVS 268 OFTP2 Improvement now available Request MVS 269 e Length of OID in certificate can be higher than 32 e Exponent of public key can be lower than 17 Improvement MVS 304 Redesign of command D SID see documentation
12. RDR remote job processing is configurable by CNTL parameter RJOBSUB Improvement RRE username can be changed in RRE update panel Improvement DELAY command in START member refer Operation_Manual doc Improvement VALIDFROM parameter for self signed certificates Improvement DF018A and DF130B00 print version information during startup Bugfix avoid SOC7 during DB command when using NOEXP license key IN662906 Bugfix avoid changing active transmissions by command S SID NAME NEWSID SID Bugfix corrected error messages in DF053V Bugfix corrected ABEND S13C in SNA task IN624614 Rel 5 01 Level 01 22 06 12 Bugfix OFTP2 Encryption isn t available if ComSecure isn t licensed Bugfix OFTP2 decryption sets the numbers of transmitted records to null Bugfix OFTP2 decryption sets user completion code to four Last changes at 27 11 15 T Systems gedas deutschland GmbH Changes T Systems page 8 of 21 Bugfix OFTP2 decryption in format TEXT and last line doesn t end with line separator Ox0d Ox0a gt Last line contains wrong data 2 last bytes or an ABEND SO0C4 occurs Improvement for TYPE MVS the VDSN is extended by additional characters Improvement SYSOUT I INTRDR remote job processing is deprecated Rel 5 01 Level 00 13 04 12 Bugfix Bugfix Bugfix Bugfix Bugfix Bugfix fixed Bugfix unnecessar
13. Specification of XNUMCHCK parameter CNTL Member now processed separately for each CTCP Rel 2 5 Level 04 07 05 02 Corrections of the following errors or problems Incorrect OFTP exchange buffer for text format if no compression is done character X 80 at the end of the last OF TP buffer of a transmitted file Automatic jobstart variable FILESIZE not correct in case of restart TCP IP component for IBM TCP IP does not work under Z OS 1 2 Last changes at 27 11 15 T Systems gedas deutschland GmbH Changes T Systems page 19 of 21 TCP IP activation continues after GETHOSTBYNAME failure Abend 0C4 sometimes occurs during file allocation Unallocation not done for a received file in case of GDG processing when GDG base entry did not exist Receiving of EERPs now accepted even if the EERP contains invalid data Autodial loop if a file is to be sent but the remote station indicates the send only option within the SSID protocol record Abend 0C4 during start of rvs in conjunction with the display of an error message Support of the stations parameter NORELAIS for SNA connections DFO80A00 check for a correct remote station ID sometimes not done Automatic transfer of received data into a SYSOUT class not done if start parameter DDEVTYP TAPE specified Routing of a received EERP to the final destination sometimes not done in case of parallel sessions timing problem R
14. dditional information GDG basic is use by another job DF037B DF 124A ERNO 66 Bug fixing FTP ABEND 0C4 corrected DFO88F ERNO 67 Bug fixing corrected problem for X SID KNUMCHCk DF048B XOT DFO95I DF095J DFO95K ERNO 46 59 61 Improvement line driver doesn t stop automatically for all TCP IP errors messages for connect improved Bug fixing if you stop the line drive the listen socket is always closed now improve XOT trace functionality Bug fixing creation of RRE via job corrected DFO80A Rel 4 05 Level 00 22 02 08 Bug fixing FTP task DF088Y deleting of datasets on non SMS managed volumes Bug fixing DF052X refresh of AR records for compression security Bug fixing DF072A00 dynamic allocation of rvs log dataset corrected Bug fixing DFO94A time check corrected during receiving SFID and EERP Bug fixing DF124A rename of datasets for compression security Improvement ABEND 837 is recovered for SNA similarly to ABEND B37 Change usage of XOT component is controlled by license key module name H Change default value of XOT receiver port from 3305 to 1998 Rel 4 04 Level 00 29 11 07 Bug fixing Odette task DFO94A invalid record byte count during receive because of incorrect handling of filler byte Reset restart position in case of invalid record byte count Bug fixing SNA restart Bug fixing DFO78B incorrect call of DFO76A Correc
15. e The Cancel command detach of rvs task interrupted KD update The message DF5406 CI IN EXCLUSIVE CONTROL BY ANOTHER TASK occurred Solution Improved handling of KD update and detach of rvs tasks Rel 2 5 Level 16 04 03 05 Problem INC 21053 Currently you can only use license keys where the expiration date is not longer than 05365 Solution Corrected check of expiration date Problem Abnormal end 0C4 occurs if you use the command Y STATIONS with wrong syntax Solution We improved command routine Problem You can t establish a SNA connection if ULS User Level Security is enabled in the license key Solution Corrected the handling with KD record bits problem disabled feature in H record Problem If you use KD dataset in SYSPLEX environment you can get a problem with duplicate indexes The Problem can occur if anew EXTEND of KD data set is created Solution The problem is fixed if your load library is APF authorized If not you have to use a primary allocation of KD data set which is large enough to avoid build of new EXTEND for KD data set Rel 2 5 Level 15 07 10 04 If you used FORMAT TEXT you couldn t change the translation table always E2ANSI or ANSIZE Now you can choose an own translation table TSD 98759 Corrected Format TEXT for FIXED datasets with external decryption compression Now all lines have the correct length record length include trailing spaces INC
16. e rvs stations table REFR STAT Dispatcher task abend S12F timer error Timeout value in case of allocation problems increased to 10 minutes Performance improvements for dataset I Os up to 16 buffers are used for reading or writing data TCP IP problems with abends SB37 for trace datasets are now solved avoided Trace will automatically be switched off if this abend has occurred Improved error recovery in case of abend S837 when receiving files PDS transfer via OF TP routing to another final destination did not work New features Functional enhancement a rvsMVS monitor controlled External Decryption and Compression Feature This functional change consists of a separate management of a new send request queue and a new receive entry queue These queues will be managed by the Service Provider Task based on a new Send Dispatcher Task and a new Receive Dispatcher Task Send Dispatcher gets control from the rvsMVS monitor to encrypt and to compress the data set before sending if it is flagged in the send request The Receive Dispatcher gets control after a complete receiving of such a data set for decompressing and decryption After successfully finishing these processes the well known rvsMVS post processing tasks like RR Entry Processing rename or GDG handling will be performed End to End Response will be transferred after successfully finishing these processes See Document Dokumentation_Rel2502 Support of parallel remote operator
17. e will never be refreshed in case of O error Bug fix MVS 198 Bug Under specific circumstances content of message DF37131 was corrupted Bug fix MVS 211 Bug Sending multi volume datasets caused ABEND Bug fix MVS 212 Bug Length of DNS name for local station was restricted to 21 characters Solution Length of DNS name for local station is now extended to 64 characters Bug fix MVS 255 Bug Wrong station displayed in some messages DF2525Q DF9I28W Bug fix MVS 232 Bug In case of routed send jobs with identical queuing time but different counters processing was done only for one of these send jobs Bug fix MVS 256 Bug In case of EERPs with identical queuing time but different counters sending was done only for one of these EERPs Duplicate key message for the other EERPs Bug fix MVS 229 If EFCHECK NO is set in definition of send job DFO80A00 SECURITY YES will be ignored even if SECURITY OPT is set for the related station Bug fix MVS 223 Bug Under specific circumstances messages from accessing control dataset are not displayed Bug fix MVS 223 Bug Update of send request in KD fails if Cl split occurs Solution Update of send request in KD will be re tried if Cl split occurs Bug fix MVS 245 Bug Operator command free DSN lt dsn gt does not work Bug fix MVS 209 Bug If using a non existing SID in creation of send job wrong message appears Rel 5 04 Level 00 25
18. ed in licence key parameters of decryption will affect decryption feature shown in table Stations tab Parameter Parameter DF080A00 Result DECRIPTION DECRIPTION not set not set decryption disabled not set DECRIPTION NO decryption disabled not set DECRIPTION EXT decryption disabled message is written DECRIPTION NO not set decryption disabled DECRIPTION NO DECRIPTION NO decryption disabled DECRIPTION NO DECRIPTION EXT decryption disabled message is written DECRIPTION EXT not set decryption is used DECRIPTION EXT DECRIPTION NO decryption disabled DECRIPTION EXT DECRIPTION EXT decryption is used Rel 2 5 Level 07 20 08 03 Includes all changes of rvsMVS 2 05 06 Patch version The user exits DFUX001 and DFUX002 are replaced by DUMMY Module Rel 2 5 Level 06 20 08 03 Patch version only You can use this version to patch rvsMVS 2 05 05 only ONLINE compression COMPRESS RVS is replaced by offline GZIP compression Changes in compression decryption module CNTL member 1 Parameter COMPRESS EXT YES and DECRIPTION EXT YES are not longer necessary The SECR COMP module is active if it is allowed by licence key Y Z 2 Use COMPRESS NO and or DECRIPTION NO to switch off decryption and or compression although it is allowed by licence key 3 the parameters GPUKID GPUKNM GPRKID und GPRKNM are removed 4 There are new parameters to control the allocation of temporary
19. el 2 5 Level 03 18 01 02 Corrections of the following errors or problems Determination of filesize not correct for files with more than 32767 used tracks Allocation error 970C for a file to be received if the filesize primary space specification exceeds the capacity of 65535 tracks Byte count overflow when sending or receiving files greater than 2 1 GB invalid byte count condition at end of transmission Check for duplicate file condition now also done in relais stations not only in stations which are final destination of the file Rel 2 5 Level 02 28 11 01 Corrections of various errors or problems Remote operating function sometimes an abend SOC4 occurred during session termination or during session setup Remote operating function wrap around mode division of line 24 to line 3 resulted in suppression of one byte if the message text exceeded 74 bytes TCP IP loop of message DF83041 ACCEPT FAILED when the maximum number of sockets CNTL parameter TCPMAX has been reached Last changes at 27 11 15 T Systems gedas deutschland GmbH Changes T Systems page 20 of 21 User abend 1720 in program DF072A rvs control dataset damaged this situation might have occurred in a multi system LPAR environment but is solved now SNA ENQ for SYSDSN sometimes held in case of GDG processing SNA files have sometimes not been sent after processing of the refresh command for th
20. ent now DFO76A The output of program expands by new missing parameters Abend 0C4 at restart Comp Decryption removed MAXRETRY does not work correctly Retry Count in KD KDRSTNO increased at open of the file Problem VOLUME CNTL and STORCLAS in RR Entry resolved DFO058A improved reentrant SECRPREF Problem with SECPREF resolved Restart Problem with restart fixed always started at position 0 Restart PDS Dataset Abend 009 fixed TCP IP Task Handling with long DNS name up to 60 chars improved Panels send request mask improved corrected parameters of decryption and compression Trace X 25 Problem with X 25 trace removed can t stop the trace Trace TCP IP Problem with TCP IP trace removed wrong content Rel 2 5 Level 09 12 09 03 Decryption Compression Improve error handling in DF052V interface of decryption to DF310A TCP IP Task Problem with long DNS Name fixed interface structure was not initialized DFO83A DF312A Odette task Problem with dynamic temporary allocation in case of REPLACE YES fixed DF117A End processing Problem with wrong filename in case of DEVICE TAPE fixed DF124A Rel 2 5 Level 08 05 09 03 Abend after command p rvs removed Last changes at 27 11 15 T Systems gedas deutschland GmbH Changes T Systems page 17 of 21 Problem with parameter TCPIPADR sometime abend removed If decryption is enabl
21. n Java 1 5 or higher Bugfix ABEND S0C4 in XOT removed Bugfix record length for U datasets set to zero in case of OF TP2 routing Improvement support of multiple private keys Improvement self signed and CA signed certificates supported Improvement keysize and validity can be changed Improvement display of certificates in batch Improvement 31Bit support for module DF018A and DF018C Rel 5 00 Level 00 15 12 10 Supporting the OFTP2 file services which means that files could be encrypted compressed and signed with the help of the internal key store infrastructure The OFTP2 Features are only running by the integration of hardware encryption facility Rel 4 08 Level 00 03 03 09 Format of Control Dataset has been changed Please refer release notes and manuals for more information about compatibility and interfaces A separate patch fixes a problem with backward compatibility in SNA LUO linedriver Please read installation notes for more information Improvement code translation when routing TEXT files can be disabled by parameter Improvement New field ACCTCPN in rvs accounting record ACTXTAREA ALCTYPE extended by line types T for TCP IP and H for XOT IN330168 Improvement New fields in rvs accounting record ACTXTAREA supporting transmissions of big files Improvement New fields in SMF record supporting transmissions of big files Bug fixing empty volume parameter in resident recei
22. tart at the beginning in case of restart So all changes of the RRE will be considered for this AR entry see message DF1197W Last changes at 27 11 15 T Systems gedas deutschland GmbH Changes T Systems page 7 of 21 Improvement If OFTP2 received files should be routed to OFTP 1 2 station only first file will be accepted All others will be rejected with SFNA duplicate file and RETRY NO Improvement expand range for DF079B up to 365 days Improvement performance optimization reduce svc s Improvement new messages if KD access failed see messages and codes Improvement transmission with OFTP2 file description are accepted by rvsMVS and is there ignored Bugfix in case of error during copy operation from or to tape user abend is suppressed and transmission is canceled Bugfix SNA file transfer corrected end time initialization GDG allocation changed from scratch to noscratch ABEND 0C7 fixed speed computing Bugfix corrected computing of allocation for PO data set transfer Bugfix corrected utility program DF079B delete old entries Bugfix use correct volume configured in RRE to store PO dataset Bugfix in case of PO dataset transfer there are too many open allocations Bugfix corrected handling with multivolume data sets DFO80A00 Rel 5 02 Level 00 18 10 12 Improvement rvsMVS is TLS ready refer Addendum_OFTP2Features pdf Improvement SYSOUT I INT
23. ted offline features security and compression for z OS 1 7 and higher Improvement a warning is written if free space for rvslog is lower than 15 and rvsMVS is stopped if free space is lower than 5 Maximal count of sessions of TCP IP LU62 and FTP is reduce to 999 Bug fixing DF052X und DF 124A receive of GDG data set with offline features Compression and Security failed Bug fixing DF54K ABEND 0C4 in DELETE function Improvement panel 2 shows additionally active and canceled records Improvement panel 6 it works also as read only panel Rel 4 02 Level 02 10 08 07 Last changes at 27 11 15 T Systems gedas deutschland GmbH Changes T Systems page 12 of 21 Newrvs usercodes as text messages in ISPF Panels Overhead in case of transmission interrupt was reduced Improve error handling when open of a dataset fails Rel 4 02 Level 00 20 07 07 Bug fixing XOT free of unused memory Bug fixing XOT cause and diag in console message Bug fixing stop cancel rvsMVS RRE s are cached by a monitor memory list see Operation_Manual chapter 5 27 new commands DS RRLIST FRRLIST R Bug fixing DFO58A abend during job submit of empty member Bug fixing DF008A abend 0C4 buffer pool Improve timer handling Bug fixing Operator Task abend 23E Rel 4 01 Level 00 25 05 07 Bug fixing XOT abend 4088 Bug fixing XOT free of unused sockets Bug fixing XOT handling of
24. unpredictable mal behaviour may occur when starting rvsMVS or refreshing stations table Bug in module DF022B was fixed Bug fix MVS 270 Bug Line tracing into a SYSOUT class does not work Bug was fixed in module DF007A TCP Bug fix MVS 264 Bug Under certain circumstances ABEND 0C4 may occur during shut down of rvsMVS Bug in module DFO96A was fixed Rel 5 04 Level 03 07 05 15 Category Reference Description Improvement MVS 217 Incomplete EERP hash contained but no signature is tolerated by rvsMVS Improvement MVS 254 New version 3 4 2 of 3 party tool Cryptlib used in OFTP2 context Improvement MVS 227 XOT line driver re engineered Improvement MVS 226 New CNTL parameter TEMPNAME with value TSTAMP or UNIQUE default controls naming of temporary datasets For unique dsn Temp dsn lt FLP gt T Mxx Dyyddd Thhmmss Cxxxx Cyyyy Routing dsn lt FLP gt RLS Mxx Dyyddd Thhmmss Cxxxx Cyyyy Improvement MVS 200 It is not longer possible to create send jobs for PO datasets where the receiver is not of type MVS Improvement MVS 258 Panel DF100P00 SEND A DATASET extended with DISP C C as Copy Last changes at 27 11 15 T Systems gedas deutschland GmbH T Systems Changes page 4 of 21 Improvement MVS 199 SIDs can now begin with digits too Bug fix MVS 216 Bug RRE JOBLIB cach
25. ve entry overwrites volume parameter in CNTL IN387528 Improvement timeout for getting ENQ in case of receiving GDG files can be modified by parameter IN339329 Improvement EERP can be suppressed by parameter Entries in station table cannot span more than one line anymore Improvement primary allocation in SNA LUO linedriver increased Bug fixing first level pointer can be set by parameter for temporary files used by online security component IN383449 Last changes at 27 11 15 T Systems gedas deutschland GmbH Changes T Systems page 10 of 21 Improvement Output of DF076A extended with earliest transmission date and time New fields for transmission of big files Rel 4 07 Level 00 14 01 09 Format of Control Dataset has been changed Please refer Release Notes and manuals for more information about compatibility and interfaces Improvement no code translation when routing TEXT files former ASCII gt EBCDIC gt ASCI Bug fixing evaluation of rename macro improved IN339392 Bug fixing Message DF5274P corrected Bug fixing abend 0C9 in DFO94A corrected abend occurred when restarting transmissions of big files Bug fixing problem with big files and unit counter corrected Bug fixing wrong message in ISPF panels when transmitting duplicate files via SNA LUO corrected Improvement recover of abend 001 on access of jobs PDS Please refer Release Notes for more information
26. w feature RACF key management New MVS 142 rvsMVS supports hardware asymmetric RSA encryption symmetric 3DES and AES encryption and hash SHA1 MVS 166 New license is required for the new feature hardware security Improvement MVS 158 KEYLABEL for RACF managed key with spaces are allowed Improvement MVS 162 export of certificates from certificate store VSAM Improvement MVS 161 If an RRE is deleted the current TSO user is stored in KD field KDUSER This KD record can be found in RVSLOG data set Bug fix MVS 155 corrected output of DF076A for PO data set transfer Bug fix MVS 159 corrected ABEND S0C4 in case of Online Security Bug fix MVS 160 corrected ComSecure and Online encryption problem if a lot of ComSecure Online Encryption tasks were started Bug fix MVS 170 corrected ABEND SOC9 during receive of SFID extension Bug fix MVS 167 corrected ISPF panel view panel 2 and 6 for different SID and same DSN Bug fix MVS 165 corrected log output if license is invalid telephone number address etc Bug fix MVS 163 corrected work buffer size for reading KD records Bug fix MVS 157 corrected check of DEVTYP during receive of SFID Bug fix MVS 155 corrected messages in messages and codes Bug fix MVS 116 initialize USER area in DF124A Rel 5 02 Level 01 12 06 13 Improvement If a RRE has changed for an existing receive entry AR the AR entry will s
27. y message DF5X22P removed OFTP2 allocation error on missing option SECRPREF distinguished name length of OFTP2 certificates increased ABEND 806 during PDS transfer fixed unknown parameter error LU62MODE fixed BAD_DATA error in case of OFTP2 compression and encryption S0C1 S0C6 as result of repeated module loading fixed related to z Os 1 13 EERP Improvement rollback function in case of KD write error Improvement license key extension Improvement encryption can be requested by ISPF Panels and in batch DFO80A00 Improvement security functions displayed in ISPF Panels and in batch DF076A Improvement OFTP2 batch messages corrected Improvement special VDSN supported used for OFTP2 certificate exchange Improvement new commands for SNMP component support start stop and automatic restart Rel 5 00 Level 02 30 06 11 Bugfix Bugfix Bugfix Bugfix Bugfix loop during decryption of datasets negotiation of security features avoiding ABENDS on invalid values for record format V avoiding duplicate temporary dataset names for SNA transmissions avoiding duplicate temporary dataset names in DFO80A00 Last changes at 27 11 15 T Systems gedas deutschland GmbH Changes T Systems page 9 of 21 Bugfix problems with DNS name resolution resolved if the IP address contains zeros Bugfix wrong state in central journal if no EERP is expected Bugfix snmpAgent runs o