1. essen ane cae 8 2 2 LOCKS TWIN EOGK roter UEM se eS 8 2 3 BUS DISTRIBUTOR TWINCONNECT 8 2 4 EXTENSION UNITS 9 2 5 ARMING DEVICE TWINA LARM En EEEE ENE SEEE ER EO EEEE ENESE en eite rennes 9 2 6 CHP Or NP SM Rae Nub m 11 2 7 CONFIGURATION SET TWINCOMM 2 2224000 02 25000100000000000000000000000000000 eite dans s sense trenes esses etr nenas 12 3 FUNCTION DESCRIPTION pr 13 3 L CODE AND LOCKING FUNCTIONS BENE ER ER deeb tee elie EY RESTE ERREUR 14 3 2 NIIS OIN e pI else 18 3 3 SERVICE EUNGTIONS Ee SERE REN E Tee EYES 20 3 4 ARMING DEVICE AND BAS CONNECTION nen tene sr sites rennen ss enter seen enn 21 3 5 OPERATIONAL u a ame EE HR EE ERE HERE CER ERE YE EE Einen 22 3 6 PREVENTION AGAINST SABOTAGE ws ua nu nenn 24 3 7 OTHER FUNCTIONS N ae a ae EIE ERR CHE BERNER TE Pe ERE EE E Tee EY Ee 24 3 8 einige wie RE 24 3 9 PC SUPPORT WITH CONFIGURATION SET TWINCOMM 22 22 224 2 0002 01000000000000000000000000000050
2. selected lock Master code Please wait Evaluate the entry Motor Open and close gradually een Cancel with ENTER CLEAR Automatic return after 150 seconds Gradual opening and closing With this function the lock can be opened and closed gradually for service purposes This function can only be activated or performed by the owner of the according master code of the according lock The user has 150 seconds to the next motor step If no key is pressed the function is cancelled The gradual opening or closing of the lock bolt is only meant for service purposes and can only be performed in an unlocked system state After this function is completed it is stored in the event log 68 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 6 25 Reset of the Arming Device TwinAlarm Menu Navigation TwinLock TwinLock Service Alarm 21 05 09 12 00 Service Alarm Reset Alarm Select the menu item Alarm Reset see menu plan 4 2 see above Reset When several locks are available Lock 01 in the system select one lock System code 222 Enter system code System code Please wait Evaluate the entry Reset Saved Action completed Automatic return after 3 seconds Alarm device reset The reset can only be performed by the owner of the system code and is saved
3. eene eene eene teer eene 73 6 30 AUTOMATIC ESTO CD CREE TT T P 74 7 PROGRAMMING OF THE SYSTEM WITH THE PC SOFTWARE TWINCOM M 75 Tle GENERAL OPERATION 76 7 2 PROGRAM THE WEEKLY PROGRAM cccececececececececececececececececececeeecececscececesseeeeeeceeeceeeeececesecesececececeeeeeseeesess 78 7 3 PROGRAMMING OF SPECIAL DAYS ccccccecesecesececececececececececececececececesececesscesscesseecseeceeeseceseeesesececeseeeseeeseeesess 79 7 4 PROGRAMMING THE BLOCKING TIME ccccccecececececececececececececececececececececesseecseeceeeceeeseceeeeeceseeececeeeeeeeseeesess 80 7 5 PROGRAMMING PARTIAL BLOCKING TIMES cccccecececececececececececececececececessceeecececececesecececeseeeseseceeeseeeeeeeeess 81 7 6 PROGRAMMING OF GENERAL SETTINGS ccccececececececececececececececseececsceceescesseseseseseeceeeeececeeeseseceeeeeeeeeeeseeesess 82 7 7 PROGRAMMING THE UNLOCKING DELAY 85 78 DISPLAY EVENT 86 7 9 MENU SIMULATOR AND MENU WIZARD 87 7 10 USER MANAGEMENT 5 eere toten Ere eo HUE C EYE STE ERES FUE 88 7 11 CUSTOMER DATA MANAGEMENT i eese eire oo poU Ve tede e ERE Fe Ee Eye EU RENE EE ee ee ROPA e 89 8 AP PEND p cC 90 8 APPHICATION
4. Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 2 System Description TwinLock 7220 Alarm is an electronic high security lock system with integrated arming device for a burglary alarm system class 3 C It is a modular system Up to 14 locks and 2 control units can be connected The security relevant system parts are designed fully redundant The system consists of the following components 2 Control units Terminals Locks Arming device BAS connection distributor Bus distributor Connector for the individual components hub Extension units TwinXT e gt 2 1 Input Unit FlatControl The input unit is mounted on the outside of the safe see assembly of the input unit and is used to control and operate the locking system code input programming etc as well as to arm or disarm a burglary alarm system using a physical code chip card 2 2 Lock TwinLock The locks are mounted within the secured area of the safe see assembly of locks The mnemonic codes are stored and evaluated inside the locks 2 3 Bus distributor TwinConnect The bus distributor TwinConnect enables the connection of the individual system components The system is connected by means of a redundant bus system BUS A and BUS B This bus system allows the entire system to be upgraded to 3 locks 8 Version 1
5. 7 8 9 Re enter the new unlocking 288 The new user code is G 9 9 saved o 9 A user can reprogram his her user code autonomously Otherwise the user only has an unlocking authorization Attention When you program a user code for the first time you must first enter the master code When programming the code you must see to the new unlocking code being checked repeatedly while the safe is open Do not use personal data when programming a code Version 1 08A 43 TwinLock 7220 Manual wrrrkorP WEZ MICROELECTRONICS Hochsicherheitsschl sser L sungen f r mehr Sicherheit 6 3 Delete a user code Menu Navigation TwinLock TwinLock Configuration System 21 05 09 12 00 Configuration System Usercodes System usercodes usercodes delete delete lock 01 Code entry user no 00 old M U code code k k delete user no O1 delete please wait usercode 01 deleted Automatic return after 3 seconds Select the menu item User Codes see menu plan 4 2 see above When several locks are available in the system select one lock clear fi ente Enter the user number 00 For the master code OOOO OOOO OOOO Enter the master code of the selected lock Select the user e g 01 to be deleted ente The selected user is deleted
6. 3901 uoneinByuos snyeys asop POTUIML ur sex zur usdo POTUML sepooJes 1 waysks t jenueo S vg sepootes Ueis s epoolejsel Wes Sun Weis 1ue s s 609072001 MIOTUIML 27 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 4 3 General Operating Instructions System Activation When idle the TwinLock System is activated by operating a menu key at the control unit After the activation a system check is performed and the individual states of the connected locks of the burglary alarm system EMA or Einbruchmeldeanlage and of the TwinLock system are displayed system check system check system check lock opened 01 BAS armed system locked Key Functions Menu Keys cear gt gt Menu navigation to the right i e next menu item lt Menu navigation to the left i e previous menu item enter Selection or confirmation clear Cancel return to previous menu item press 2 seconds return to system menu 0 9 Numeric keys to
7. TwinLock TwinLock Configuration Lock 21 05 09 12 00 Configuration Lock Express blocking lock Select the menu item Express blocking express Dlocking see menu plan 4 2 see above express blocking When several locks are available Lock 01 the system select one lock Master code Enter the master code of the code selected lock Master code Evaluate the entry please wait express blocking Display current settings dud Start the entry with ENTER express blocking Enter the new end time E 21 06 04 05 09 express blocking Action completed saved Automatic return after 3 seconds Express blocking Express blocking can be programmed for each lock Express blocking is active from the time when it was programmed and stays active until the specified end time During this period the according lock can not be unlocked The express blocking programming can only be performed by the owner of the according master code of the respective lock and is saved in the event log Default express blockings 00 00 00 00 00 This function can not be programmed via the PC software 48 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 6 8 Program the Activation of the TwinXT Lock I O Menu Navigation TwinLock TwinLock Configuration Lock 21 05 09 12 00 Configuration Lock Lo
8. 86 Version 1 08A TwinLock 7220 wopr Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 7 9 Menu Simulator and Menu Wizard Einstellungen System Datum Uhrzeit m Usercodes d L schen men Usercode Anzeige Codeverkn pfung Schloss Teilsperrung Schloss 1 0 Zwangsfolge Alarm Twinalarm aktiv Bee Benutzer neu Benutzer Anzeig Benutzer abmeld stiller Alarm Service __ System Reset T T Import Export Versionsabfrage SE Schloss anmeld Schloss Reset T Versionsabfrage Motor Service Alarm Reset T Versionsabfrage Datei Chipkarte Sprache Tools Men assistent Info Zeitprog 1 Zeitprog 2 Einstellungen Schl sser bersicht Protokoll Men simulator kundendat 4 gt TwinLock 21 05 2009 12 00 With the help of the menu wizard individual menus in the user interface of the lock can be activated or deactivated The structure can be simplified for the user or individual menus to which the user should have no access can be selectively hidden With the help of the menu simulator the new user interface can be simulated Version 1 08A 87 TwinLock 7220 Manual MICROELECTRONICS L sungen f r mehr Sicherheit 7 10 User Data Management E TwinComm TwinLock Datel Chipkarte Sprache Mendasisten
9. Automatic return after 3 seconds Code combination code linkage Comment Selection by means of arrow keys and ENTER 1 Single code normal 2 Four eye code 2 users 3 Six eye code 3 users This function can also be configured via the PC software TwinComm 46 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 6 6 Setting the Date Time and Weekday Menu Navigation TwinLock TwinLock Configuration System 21 05 09 12 00 Configuration System Date Time system Select the menu item BESTER see menu plan 4 2 system code Enter system code code k k system code please wait Evaluate the entry Select time date weekday time 10 01 Mo Display current settings date 20 12 02 time 12 00 Mo Reenter date date 18 08 02 time or weekday date time saved Action completed Date Time The date time weekday can only be changed by the owner of the system code This action is saved in the event log Attention The correct setting of the date time weekday is the basis for all timer programs in the system or the event log to run properly Version 1 08A 47 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 6 7 Program Express Blockings Menu Navigation
10. Import Export System code Code System code Please wait Import Export Data import Data import Insert card Data import Configuration Read data gt gt gt gt gt gt Data import Remove card Select the menu item Import Export see menu plan 4 2 see above Enter system code Evaluate the entry Select data import with the menu keys Insert the TwinCard configuration TwinCard configuration Select Export configuration Data is read from the card into the system Remove card The data import procedure is stored in the event log Version 1 08A 59 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 6 18 Read New System Language To switch the language of your system you need an according TwinCard language The language cards can be ordered on request Menu Navigation TwinLock TwinLock 21 05 09 12 00 Import Export Twinkeck Select the menu item Import Export Import Export see menu plan 4 2 System code Enter system Code code System code Please wait Evaluate the entry Import Export Select data import 8 0 9 Data import with the menu keys re Insert the TwinCard language Data import Insert card TwinCard language Select Export con
11. TwinLock 7220 INSYS L sungen f r mehr Sicherheit TwinLock 7220 Manual Twin Lock EN 1300 M 105361 M 102309 High Security Lock Class 3 VdS G 105133 G 102013 IAS ACE Switching Element Class C G 106016 G 106015 IAS ACE Locking Element Class C Version 1 08A 1 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit Copyright May 09 INSYS MICROELECTRONICS GmbH Any duplication of this manual is prohibited All rights on this documentation and the devices are with INSYS MICROELECTRONICS GmbH Regensburg Restrictions of guarantee This handbook contains a concise description The compilation of the text has been made with the utmost care Despite all efforts there may be deviations to the actual functions No guarantee can therefore be given for the accuracy of the contents We can neither assume legal responsibility nor any liability for incorrect information and their consequences Suggestions for improvements and comments are always welcome Trademarks and logos The use of a trademark or logo not shown below does not indicate that it is freely available for use INSYS is a registered trademark of INSYS MICROELECTRONICS GmbH Windows is a registered trademark of Microsoft Corporation Publisher INSYS MICROELECTRONICS GmbH Carl Wittkopp GmbH amp Co KG Waffnergasse 8 Sternbergstr 5 93047 Regensburg
12. Parllel code Save setting Saved Action completed Notes Only possible if there are 2 or 3 locks in the system Unlocking procedure During the unlocking procedure the status of lock 01 is queried first If lock 01 is closed an unlocking code must be entered without selecting lock 01 beforehand If lock 01 is open the condition of lock 02 is automatically queried When lock 02 is closed an unlocking code must be entered without selecting lock 02 beforehand Lock 02 unlocks gt Programming of the codes In all locks the same codes must be programmed for the according users e g User 08 Code Lock 1 08080808 Code Lock 2 08080808 or Code Lock 3 08080808 1 For this functionality the explicit four eye code code combination is deactivated 2 This function is only approved for 2 or 3 lock operation Version 1 08A 71 TwinLock 7220 Manual Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 6 28 Interrupt Active Timer Programs Menu Navigation TwinLock 21 05 09 12 00 TwinLock 21 05 09 12 00 Timer Prog Cancel Enter code Enter code Code okckckckckck k Notes In the system menu first the key F2 then key 2 is pressed Confirm the entry with Enter Enter the quick unlocking code Lock 01 Active timer programs are interrupted for an unlocking procedure A running timer
13. Alternatively power supply unit 12 VDC via TwinConnect Stand by condition approx 30 Input condition display active approx 55mA 4 92 x 3 54 x 2 44 inches L x W x H 32 F 122 F 75 RH Environment class according to VdS IP 30 9 VDC Alternatively power supply unit 12 VDC via TwinConnect Alternatively emergency power supply via mini DC jack Stand by condition approx 30 Input condition display active approx 55mA 5 51 x 4 02 x 0 98 inches L x W x H 32 F 122 F 75 RH Environment class according to VdS IP 30 9 VDC Idle state approx 40uA Motor operation without bolt load approx 110 mA 3 54 x 2 40 x 1 34 inches L x W x H 32 F 122 F 75 RH Environment class according to VdS IP 30 92 Version 1 08A TwinLock 7220 wrrrkorP WEZ Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit Arming Device TwinAlarm Power supply Current consumption Dimensions Environment Protection class Connections 12 VDC Idle state approx 10mA each active output relay approx 20mA 3 94 x 5 91 x 1 38 inches L x W x H 32 F 122 F 75 RH Environment class according to VdS IP 30 2 RJ11 connectors for the connection of the system busses A and B Terminal connectors for the serial interface RS232 RX TC and GND 1200 baud 8N1 power supply 12 VDC distributor inputs and outputs Bus distributor TwinConne
14. Action completed Only the according owner of the master code can delete user codes This action is saved in the event log The function itself can only be performed at the control unit 44 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 6 4 Display the Programmed User Codes Menu Navigation TwinLock TwinLock Configuration System 21 05 09 12 00 Configuration System Usercodes usercodes Select the menu item Display User Code display usercode see menu plan 4 2 see above display usercode When several locks are available Lock 01 in the system select one lock eg G O master code Enter the master code of the Code selected lock master code please wait Evaluate the entry prog U codes 03 Navigate through the user numbers Usercode 01 OK Use the arrow keys lt gt Terminate with ENTER CLEAR Display the Programmed User Codes For each lock the users can be displayed which were entered in it This means that not the codes themselves are displayed but the status programmed not programmed The display of a programmed user code can only take place by entering the according master code of the lock Comment Prog U Codes 03 1 line Number of programmed user codes for this lock Usercode 01 OK e g progr codes 03 Three user codes are
15. Chip card for the configuration of the system language German English Czech Portuguese Version 1 08A 11 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 2 7 Configuration Set TwinComm The TwinLock system can be configured fast and conveniently using the program TwinComm in connection with the chip card reader of the configuration set and the chip card TwinCard configuration All settings and the event log can be displayed printed and saved TwinCard configuration 12 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 3 Function Description Function Overview Code and Locking Functions 1 Master code per lock 1 System code 35 User codes per lock Status indicator for programmed user codes Unlock amp lock by entering the security code Forced Sequence Parallel code Lock amp Code Automatic lock with door switch Code linking Four eye code six eye code Silent alarm Code manipulation detection Quick unlocking code Timer Functions Weekly program Special days Blocking time Partial blocking times Express blocking Timer program interruption Time delay Alarm sabotage delays Automatic switching to daylight savings time Service Functions Event log 768 events Import export of the configuration via chip card System language c
16. open time dealy v code entry user no 01 v 0123456789 code v code entry please wait BAS active and armed and lock 1 open please wait v open lock 01 open system unlocked disarming BAS disarmed BAS user card out lock opens Time delay expires chosse user number enter gt confirmation enter code wtih menue keys BAS now disarmed remove card TwinLock ID TwinCard code access 30 Version 1 08A TwinLock 7220 wrrrkorP INEN MICROELECTRONICS Hochsicherheitsschl sser L sungen f r mehr Sicherheit 5 1 Unlocking a Lock TwinLock open lock 01 code entry user no 01 lt 0123456789 code kkk kkk code entry please wait code entry 62 user no 01 lt 0123456789 code k k kkk Code entry 63 user no 01 lt 0123456789 code Xxx open delay XXminXXsec code entry user no 01 lt 0123456789 code Xxx open lock opened 01 open system unlocked Automatic return after 3 seconds Select the menu item Unlock see menu plan 4 2 When several locks are available in the system select one lock When Forced Sequence is selected lock 01 is unlocked first Select the user number gt Enter the unlock code Enter a
17. 1 08A 14 05 09 I Subject to correction 96 Version 1 08A
18. RS232 Port This port enables the connection of the system to a PC a serial printer or a modem The protocol or individual online log entries can be sent for example Interface parameters 1200 baud data format 8N1 no handshake It is possible to release or block the system via modem ISDN GSM This functionality is identical to the release signal function via an input contact For a remote release the arming device must be configured accordingly see assembly instructions Release procedure Dialup and connection establishment oa wel Medan to the TwinLock system 2 Identification requirement gt send from ES Le TwinAlarm 2 3 Response 222 Requirement Release 9 Response OK or NOK Termination TwinAlarm ioi Modem ISDN GSM As soon as the system reports OK the release time starts to run The system may now be unlocked After 120 seconds the system is locked again Version 1 08A 21 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 3 5 Operational Safety Redundancy A dual bus system and a dual electronic and mechanical locking system in the locks guarantee high system stability The two identical system parts are completely independent fr
19. The evaluation of the partial blocking time takes place during each locking procedure If lock 01 must be quickly locked despite an active partial locking time the ENTER key must be pressed during the locking procedure when Locking lock 01 Partially locked is displayed This will skip the partial locking time and close lock 01 The partial locking time can be combined with the function automatic locking via door switch and will perform the locking after the configured total blocking time has started Factory setting Su 00 00 00 00 Partial blocking time deactivated 00 00 00 00 Attention To ensure proper functioning of the weekly program the correct setting of the date time and weekday is required Version 1 08A 81 TwinLock 7220 ie Manual L sungen f r mehr Sicherheit 7 6 Programming of General Settings TwinComm TwinLock Datei Chipkarte Sprache Tools Men assistent Info Zeitprog 1 Zeitprog 2 Einstellungen Schidsser Ubersicht Pro WITTKOPP Chipkarte lesen Chipkarte schreiben TwinLock Karte ist aktiviert und Freigegeben 2 Code linkage Programming the four eye code principle For unlocking and programming 2 code entries each are required Parallel code Only possible if there are 2 or 3 locks in the system Unlocking procedure During the unlocking procedure the status of lock 01 is queried first When lock 01 is closed
20. programmed all in all 2 line Displays which user code is programmed OK programmed NOK not programmed e g ucode 01 OK User code 01 is programmed Version 1 08A 45 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 6 5 Code combination Programming Four Six Eye Code When code linkage was selected four eye code six eye code the lock can only be unlocked or programmed by entering 2 or 3 codes The arrangement of the 2 or 3 codes is random The function applies to the entire system i e each lock must be unlocked with 2 or 3 codes when code linkage is activated The programming of this function can only be performed by the owner of the system code and is saved in the event log Note The code combination linkage can only be programmed if 2 or 3 user codes are programmed User codes can only be deleted when the code linkage was deactivated beforehand Menu Navigation TwinLock TwinLock Configuration System 21 05 09 12 00 Configuration System Code combination system Menu item Code combination code combination select see menu plan 4 2 see above t d eee Enter system code system code Evaluate the entry Please wait code combination Select the linkage type code combination code combination deleted paved Action completed 1 user 2 3 user
21. 1 08A TwinLock 7220 wrrrkorP WEZ MICROELECTRONICS Hochsicherheitsschl sser L sungen f r mehr Sicherheit Status messages system check failure Bus A system check failure Bus B system check failure motor A system check failure motor B System check failure motor AB Status DMS XX Error General Error Messages invalide code invalide input failure BUS A failure BUS B failure motor AB COM Error Error Serial No Lock can no longer be addressed at bus A Please call customer service Lock can no longer be addressed at bus B Please call customer service Final bolt position of the lock at bus A is not accessible Please call customer service Final bolt position of the lock at bus B is not accessible Please call customer service Final bolt position of the lock is not accessible at bus A or bus B Please call customer service General lock fault Please call customer service Code entry incorrect Please enter correct code Incorrect or invalid entry Check entry and retry Addressed component at bus A does not respond Please call customer service Addressed component at bus B does not respond Please call customer service Error when unlocking locking a lock Please call customer service Error during communication between control unit and lock Please call customer service Error during communication between control unit and lock Con
22. Germany 42551 Velbert Germany Phone 49 0 941 58692 22 Phone 49 0 2051 9566 0 Fax 49 0 941 563471 Fax 49 0 2051 9566 66 Internet http www insys security de Internet http www cawi com Errors excepted Subject to technical changes Date May 09 Version 1 08A 2 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit this document The manual contains detailed information for the operation and the programming of the high security lock TwinLock 7220 and is mainly intended for the system MASTER responsible for the system configuration and administration For users we recommend the Quick Reference Guide The concise document contains all important information required for normal system operation in short form The document ASSEMBLY INSTRUCTIONS has been created to assist with the installation of the system This contains all information for the implementation of the TwinLock system Sections marked with this symbol contain important notes regarding the safe damage free operation of this product Please read these sections carefully Version 1 08A 3 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit Contents 1 SYSTEM DIAGRAM SE a 6 2 SYSTEM DESCRIPTION 8 231 INPUT
23. System 21 05 09 12 00 Configuration System Master codes System Select the menu item Master Codes Master codes see menu plan 4 2 see above cear 7 ente Master codes When several locks are available Lock 01 in the system select one lock Master code Enter the master code of the pe selected lock 000 7 9 Master code 2 Please wait Evaluate the entry 97 2 Enter the new master code 5 6 of the selected lock Confirm code Reconfirm the new master conia dil code once more 0009 OO 00A New M code Please wait Save the new code New M code Saved Action completed Automatic return after 3 seconds Besides the normal unlocking authorization the master code is also authorized to configure the lock for quick unlocking and single unlocking with four six eye code The master code of lock 01 is at the same time the system code for system configuration and service functions When entering the code the user 00 is the master Version 1 08A 41 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit ATTENTION The default code 1234567 8 is pre programmed for the master of each lock The user codes no 01 35 of the individual locks have been deactivated by the manufacturer For security reasons the master codes of the individual locks must be changed immed
24. TwinAlarm enable M uis Select the menu item TwinAlarm enable see menu plan 4 2 see above 9 7 System code Enter system code Code System code Evaluate the entry Please wait TwinAlarm enable Display of the current setting 5206 and selection of the new condition clear 0 ente Save setting TwinAlarm active Action completed Saved TwinAlarm active Please wait Automatic return after 3 seconds TwinAlarm active The TwinLock system can be connected to a BAS center via the arming device TwinAlarm When the alarm function is activated the functions of the BAS control the inputs and outputs and the RS232 port are available The activation deactivation can only be performed by the owner of the system code and is saved in the event log Possible message TwinAlarm a No arming device connected or Se eee arming device cannot be addressed 5 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 6 12 Register alarm user Menu Navigation TwinLock TwinLock Configuration Alarm 21 05 09 12 00 Configuration Alarm New user Alarm Select the menu item New user New user see menu plan 4 2 see above 2 Enter system code System code Please wait Evaluate the entry New user Select ne
25. an unlocking code must be entered without selecting lock 01 beforehand When lock 01 is open the condition of lock 02 is queried automatically When lock 02 is closed an unlocking code must be entered without selecting lock 02 beforehand Lock 02 unlocks 82 Version 1 08A TwinLock 7220 wrrrkorP WEZ Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit Activate TwinXT Quick unlocking code General Battery warning limit Switching to Daylight savings time Manual locking Code query Programming of the codes In all locks the same codes must be programmed for the according users e g User 08 Code Lock 1 08080808 Code Lock 2 08080808 or Code Lock 3 08080808 Notes 1 For this functionality the explicit four eye code code linkage is deactivated 2 This function is only approved for 2 or 3 lock operation Lock I O The inputs and outputs of the extension unit TwinXT are activated and queried A user code that skips the unlocking delay can be defined as quick unlocking code Factory setting in the lock User 09 Forced sequence programmable i e the unlocking and locking sequence Unlocking Lock 01 gt Lock 02 Locking Lock 02 gt Lock 01 With this function the threshold of the battery warning can be set between 6 8 V and 9 3 V Critical dropping of the supply voltage 15 automatically detected and the following message is displayed TwinL
26. enter timer programs etc F1 Arming a BAS only possible in the system menu F2 Display of the current battery voltage only possible in the system menu Code input Unlocking and locking codes may only be entered via the menu keys Using the arrow keys the cursor is placed over the desired digit and selected with the enter key As an alternative the code can also be entered in the configuration and service area using the keyboard This function must be activated in the menu Settings System General see manual cear c gt erie TwinControl FlatControl Entering the code using the menu keys Entering the code using the numeric keypad Menu Navigation 28 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit System Menu The start page of the menu structure is called system Th 21 05 09 12 00 The system menu consists of one editable line line 1 system line which can contain individual text and the current date time display line 2 Programming the Code Important notes regarding the programming of the code For security reasons switch the system code or the master code of the individual codes immediately after Installation The default code 12345 6 7 8 is pre programmed for the user no 00 master system master The user codes no 01 35 of the individual locks have been deacti
27. program weekly program special days blocking time express blocking can be interrupted by entering the quick unlocking code The timer program is now interrupted for one unlocking process The unlocking process can be performed The entering of the quick unlocking code and the blocking time interruption are logged The owner of the quick unlocking code also has the opportunity to trigger a silent alarm 72 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl s MICROELECTRONICS L sungen f r mehr Sicherheit 6 29 Ignore Bolt System Position Switch Menu Navigation aa Service System ERI 09 12 00 System Central inactive System Central inactive clear lt gt ente Central inactive Select Yes Yes No clear gt ente Central inactive 5 A Stored The setting is stored The bolt system position switch which may be connected to TwinAlarm or TwinXT is ignored for one locking procedure This means that the system can still be locked properly even if the switch is damaged Version 1 08A 73 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 6 30 Automatic Locking The TwinLock system can be automatically locked using a door switch or a bolt system position switch The switch is con
28. programs The defined release time of the normal time delay is used as release time Example Unlocking code 1 2 3 4 5 6 7 8 gt gt Alarm code 1 2 3 4 5 6 7 9 Code Manipulation When the code has been entered incorrectly for four times a blocking period of 1 minute is activated During this blocking time no opening procedure may be performed Each further incorrect code entry increases the blocking time by one minute The maximum blocking period is 15 minutes see also timer programs and prevention against sabotage wrong code blocking period 16 Version 1 08A TwinLock 7220 INSYS MICROELECTRONICS WITTKOPP Hochsicherheitsschl sser L sungen f r mehr Sicherheit Code distribution in the TwinLock 7220 system ae te ee EE Qoo Qo lock 1 lock 2 TwinAlarm TwinLock secured area 1 systemcode 1 mastercode 35 usercodes mnemonic codes 1 mastercode mnemonic codes 35 usercodes 35 Codes TwinCard code access physical codes Version 1 08A 17 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 3 2 Timer Functions Weekly program There are 2 definable opening periods for each weekday Monday to Sund
29. 0000000 25 4 OPERATION issues ass L R 26 4 1 DISPLAY AND CONTROL ELEMENTS OF THE INPUT EQUIPMENT eee nennen en enne enne nns 26 4 2 MENU NAVIGATION CES 27 4 3 GENERAL OPERATING 2 2 02 0 0020200000010000000000000000000 28 5 GENERAL OPERATION 85 8 30 SL WINTOCKING A DOCE EE 31 52 LOCKRING ROCK ee re EE EIS 32 5 3 STATUS REQUEST OF A DOCK trier eter nennen en antenne ee edu hen 33 S4 RESPONSES cr tee ee en Beben 34 5 5 OPERATION WITH A BURGLARY ALARM SYSTEM 5 36 3 5 1 Arming the Burglary Alarm System unie ted aad arc Davina e cete ce dan 36 5 5 2 Disarming the Burglary Alarm System eese teen nennen nennen 38 EMERGENCY SHUTDOWN OF THE BAS 4221 2 00 0101800 0000000000000000000000000000000000000 39 6 PROGRAMMING THE SYSTEM WITH THE CONTROL UNIT 40 6 1 REPROGRAMMING MASTER SYSTEM CODE esses 41 6 2 PROGRAMMING AND REPROGRAMMING OF A USER 4 4 44 0440 20002 0000000000000000000000000000000 00
30. 0000000000000000000000000000000 58 6 17 READ CONFIGURATION FROM CHIP 59 6 18 READ NEW SYSTEM LANGUAGE 60 4 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 6 19 INSTALL CHANGE LOCKS IN THE SYSTEM ccccccessssceceescececsececeessececeeeececsseeeceesseeccseeeceessseecseseecenseteeees 61 6 20 RESET THE INPUT UNIT TWIN CONTROL FLAT 63 6 21 QUERY OF THE CONTROL UNIT VERSION u einsehen 65 6 22 VERSION QUERY OF THE LOCKS RR HERO ERSTE RERO ERE EAR OE RE EAT 66 0 23 67 6 24 LOCK MOTOR SERVICE 5 PEE PER TEE CER AERE SERERE 68 6 25 RESET OF THE ARMING DEVICE 2 21 1 70 44400 0010000000000000000000000000000 69 6 26 VERSION QUERY OF THE ARMING DEVICE 70 6 27 ACTIVATE PARALLEL CODE nen e Eee TENEO ERE SA 71 6 28 INTERRUPT ACTIVE TIMER PROGRAMS cccecesececececececececececececeeecececececscecseeeseececeseceeeeeceeeseeeceeeeeeeeeseceeesess 72 6 29 IGNORE BOLT SYSTEM POSITION SWITCH eene ene emen
31. 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit TwinConnect allows the connection of the input unit the arming device and up to 3 locks There is also the possibility to cascade several bus distributors i e to connect several TwinConnect units in series to be able to connect several locks In addition TwinConnect has a power supply unit 12 VDC which can supply the TwinLock lock system When the arming device is connected however the system must be supplied through the BAS 2 4 Extension Unit TwinXT The TwinLock system can very easily be extended by 4 inputs and 2 outputs by means of the extension unit TwinXT Basically a TwinXT can be connected to each lock in the system Consequently each lock can be specifically locked or released and each lock can have a bolt system contact 2 switching inputs release bolt system contact for lock 1 2 switching inputs release bolt system contact for lock 2 2 relay outputs status silent alarm 30V 1A Power supply 12 VDC Antitamper loop with tamper switch 2 5 Arming Device TwinAlarm The arming device TwinAlarm is mounted inside the safe and is used as a connecting link between the terminal TwinControl or FlatControl input unit and the locks and a burglary alarm system BAS as well as to connect a serial printer PCs and as a distributor for the burglary alarm system bolt contacts doo
32. 4 43 6 3 DELETE A USER CODE ir ose nee blue Pee eee nance 44 6 4 DISPLAY THE PROGRAMMED USER 8 201 200 0 0 20 2001 000000000000000000000000000000000000 45 6 5 CODE COMBINATION PROGRAMMING FOUR SIX EYE 46 6 6 SETTING THE DATE TIME AND enne nete seen 47 6 7 PROGRAM EXPRESS BLEOCKINGS de eter erbe abe ih kueche an 48 6 8 PROGRAM THE ACTIVATION OF THE TWINXT LOCK 2 2200 000 00000000000000000000000505005 49 6 9 OPENING DURESS PROGRAM FORCED 50 6 10 PROGRAM UNLOCKING TIME DELAY 2 2 2 1 51 6 11 ACTIVATE ARMING DEVICE 0000000000001010000000000000100000000000 52 6 12 REGISTER ALARM USER itti ERA EEEE 53 6 13 DISPLAY REGISTERED ALARM USERS eene nete neta 55 6 14 REMOVE BAS USER DEREGISTER ALARM 5 56 6 15 PROGRAM SILENT ALARM due aber 57 6 16 WRITE LOG AND CONFIGURATION TO CHIP CARD 44200000002000000000
33. S A ENEE EE ets eed eve Posee eo vA Pee eI oer exitos ter 90 8 1 2 90 9 1 2 Network Connection e et rec 91 82 TECHNICAL D ATA 92 94 Revision History Version 1 08A 5 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 1 System Diagram TwinLock 7220 Alarm Se i TwinLock ID TwinCard code access Gesicherter Bereich TwinLock TwinConnect TwinLock BUS B Zeitsperre inaktiv TwinAlarm TwinLock TwinLock ID TwinCard code access Version 1 08A TwinLock 7220 wopr Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit TwinLock 7220 base system 2 1 FlatControl 2 lock system with XT a TwinConnect TwinXT x te TwinLock 7220 base system 2 1 FlatControl 1 lock system with XT 2m TwinConnect L TwinXT TwinLock
34. The chip card is not required for deletion as the code entry is removed from the arming device Only the owner of the system code can delete an alarm user This action is stored in the event log 56 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 6 15 Program silent alarm Menu Navigation TwinLock TwinLock Configuration Alarm 21 05 09 12 00 Configuration Alarm Silent alarm Al te ie Select the menu item Silent alarm see menu plan 4 2 see above System code Code kx Enter system code System code Please wait Evaluate the entry Silent alarm Yes No Display of the current setting and selection of the new condition Silent alarm Alarm delay 00 Enter the unlocking delay time Silent alarm Silent alarm Saved Deleted Action completed Automatic return after 3 seconds Silent alarm A silent alarm is indicated via the alarm output of the arming device relay output When the function is activated a silent alarm is triggered by entering a valid unlocking code last code digit 1 see example and stored in the event log A time delay can be set 00 99 min which is only activated during the triggering of an alarm The defined release time of the programmed normal time delay is used as release time The function Silent alarm can only be performed by the own
35. an be configured using the chip card Reset of the individual system components Query of the system component version System components login logout Step by step operation for motor test System line free configurable System status indicator Voltage monitoring Arming Device and BAS Connection Activate arming disarming Distributor BAS Inputs BAS ready block disarming release acknowledge timeout bolt system contact BAS Outputs Silent alarm armed disarmed state Connection facility for 2 more bolt system and door contacts each Antitamper loop with area sensor and cover contact Control points for resistance monitoring RS232 Port Version 1 08A 13 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 3 1 Code and Locking Functions Master code Each lock has a master code user ID 00 8 digit master code The master code has the authorization to program lock specific procedures e g time delay user codes etc or to unlock respectively The master code can not be deleted or deactivated ATTENTION The default code for the user 00 Master of each lock is the pre programmed code 1234567 8 The user codes no 01 35 of the individual locks have been deactivated by the manufacturer For security reasons the master codes of the individual codes must be changed IMMEDIATELY When programming the code you must see to the new unlocki
36. atus status Info see menu plan 4 2 Status Selektion lock if there are more lock 01 Locks in the system The status of the selected Status info component is displayed Automatic return after 3 seconds Version 1 08A 33 TwinLock 7220 Manual wrrrkorP WEZ Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 5 4 Responses Unlocking Messages open time lock week open time lock day open blocking period open part lock time open system blocked Open cancel Blocking time open terminal switch open manipulation restart or voltage drop No unlocking possible because the current time is not within the time window defined in the weekly program No unlocking possible because the current date coincides with the date of a defined special day No unlocking possible because the blocking time program is active No unlocking possible because the system is in part lock time mode No unlocking possible because the input RELEASE at the arming device is not active An active timer program is cancelled by activating the input TIMEOUT in the secured area The control unit was switched or re initialized At the last code entry a user entered a wrong code more than three times Attention The system was either restarted or there was no power supply or the battery compartment was opened only for TwinControl 34 Version
37. ay The system can only be unlocked within the set time window The individual weekdays can also be completely locked e g on weekends The programming is performed using the system code Special days 30 definable days on which the system can not be unlocked e g public holidays The programming is performed using the system code Blocking period Period up to three months during which the system can not be unlocked Programming of the start time date time and the end time date time is done using the system code e g company holidays Partl lock time Two time periods for each of the seven days of the week are available during which the system may be partially locked The partial locking is only designed for two lock operation Within the part lock time only lock 2 is closed lock 1 remains open The part lock time may be combined with the function automatic locking via door switch Express blocking Period during which a lock is blocked i e can no longer be unlocked The programming of the end time date time is performed using the according lock master code The express blocking starts with the programming time and must be performed individually for each lock Timer program interruption A person locked in the secured area can deactivate an active timer program weekly program special days blocking period part lock time with a key to enable opening the system from the outside by entering an unlocking co
38. cherheitsschl sser Ie L sungen f r mehr Sicherheit CHIPDRIVE micro COMI Karte ist aktiviert und freigegeben Before the chip card reader is used the serial interface to which the reader is connected must be activated The setting is done in the menu Chip card gt Configure Or the user is prompted to select the interface when the PC software starts for the first time Schnittstelle Schnittstelle 76 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit License chip card To active the PC software you will need a license chip card which is a part of the scope of delivery of the configuration set After TwinComm is started this card must be inserted into the chip card reader WITTKOPP Bish Solutions for higher security TwinLock ID Information i Bitte legen Sie die Lizenzkarte ein TwinCard After the license card has been read the according locking system can be selected gt TwinLock To read the data from the chip card TwinCard configuration it must be inserted WITKOEE Se into the chip card reader Then push the button Read chip TwinLock TE To save the data to the chip card TwinCard configuration it must be inserted into the chip card reader Then push the button Write chi
39. ck I O Lock Select the menu item Lock Lock I O see menu plan 4 2 see above gt System code Enter system code Code System code Evaluate the entry Please wait Lock 1 0 Activate TwinXT Yes No clear Bo ente Lock I O Saved Action completed Automatic return after 3 seconds Lock The inputs or outputs of the locks can be programmed by means of the master code system code of lock 01 The following functionality is achieved Input functions Locking feature contact for external release blocking of the lock Locking after bolt contact query Output functions Silent alarm relay contact for silent alarm messages Display of the lock bolt position relay contact This programming action is saved in the event log Note The function Automatic locking via door contact can only be programmed via the PC software TwinComm see Chap 6 30 The function of the inputs can also be re configured Active contact closed or Active contact open Factory setting TwinXT inactive Version 1 08A 49 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 6 9 Opening duress program forced sequence Menu Navigation TwinLock TwinLock Configuration Lock 21 05 09 12 00 Configuration Lock Opening duress M od Select
40. ct Power Supply Current consumption Dimensions Environment Protection class Extension Unit TwinXT Power Supply Current consumption Dimensions Environment Protection class 12 VDC optional For power supply operation 12 VDC Approx 9 mA Only as distributor 0 mA 3 94 x 2 36 x 0 98 inches L x W x H 32 F 122 F 75 RH Environment class according to VdS IP 30 12 VDC optional Only for output relay operation For power supply operation 12 VDC Approx 20 mA Per relay Only when the inputs are used 0 3 94 x 2 36 x 0 98 inches L x W x H 32 F 122 F 75 RH Environment class according to VdS IP 30 Version 1 08A 93 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 8 3 Notes 94 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit Version 1 08A 95 TwinLock 7220 WITTKOPP EINER ass Manual L sungen f r mehr Sicherheit Revision History MB 1 05 26 03 06 Supplements partial blocking time recurring special days locking with door switch 19 04 06 Layout adjustment 30 10 06 New Layout TwinCards
41. de Afterwards the timer program is resumed The key is connected to TwinAlarm It can not be connected to TwinXT Time delay Unlocking delay individually configurable for each lock 00 99 min A release time 00 99 min can be programmed for each unlocking delay After the time delay expiration an unlocking code must be reentered The programming is performed using the according lock master code A user can be assigned a quick unlocking code function to bypass this program 18 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit Alarm sabotage delays When the unlocking code was entered incorrectly 4 times a time delay of 1 minute starts For each further attempt with a wrong code the waiting period is extended by 1 minute up to a maximum of 15 minutes When a silent alarm is triggered a waiting period with a set duration will start These special programs can not be bypassed or interrupted see also code functions and prevention against sabotage Blocking time interruption A running timer program weekly program special days blocking period part lock time can be interrupted by entering the quick unlocking code This code is entered in the system menu with the following sequence Press the key F2 gt Press the key 2 Now the quick unlocking code for lock 1 must be entered The timer program is now interrupted for one unl
42. ed to not open the lock after it is entered the code is queried and teh BAS is disarmed Two codes may be defined The system line is displayed in the 1st line of the main menu on the display of the control unit It can be changed and set as required anytime 84 Version 1 08A TwinLock 7220 MICROELECTRONICS L sungen f r mehr Sicherheit 7 7 Programming the Unlocking Delay TwinComm Datei Chipkarte Sprache Tools Men assistent Info Zeitprog 1 Zeitprog 2 Einstellungen Schl sser bersicht Protokoll Men simulator Kundendat wirTTKOPP EED For each lock an unlocking delay of 01 99 minutes can be programmed A release time of 01 15 minutes can be programmed as well during which a code entry must take place after the unlocking delay has expired Unlocking delay 00 No unlocking delay Release time 00 No code entry after unlocking delay The lock is immediately unlocked Version 1 08A 85 TwinLock 7220 Hochsicherheitsschl sser Manual L sungen f r mehr Sicherheit 7 8 Display Event Log E TwinComm TwinLock DAR Datei Chipkarte Sprache Tools Men assistent Info Zeitprog 1 Zeitprog 2 Einstellungen Schl sser bersicht Protokoll Men simulator Kundendaten Benutzerdaten Benutzeri_4 gt Protokolldaten TwinComm Datum Aktion Status Zusa
43. em language The system language can be transferred using the chip card TwinCard language This card is available in several languages and must be requested separately More functions Reset of the individual system components Query of the system component version System components login logout Step by step operation for motor test Operation of several control units 20 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 3 4 Arming Device and BAS Connection Activate arming disarming The main task of the arming device is to arm or disarm a connected BAS Disarming is basically an unlocking process which requires an additional physical code in form of a chip card Up to 36 different card users can be logged on The user management is performed by the system master The current codes of the logged on cards are saved in TwinAlarm and change after each use The BAS arming procedure can also be tied to a physical code to avoid arming by an unauthorized person distributor BAS Inputs BAS EMA ready block disarming release acknowledge BAS adjustment via configurable inputs BAS Outputs Silent alarm armed disarmed Other Inputs Timeout bolt system contact Other outputs Status Connection facility for two more bolt systems and door contacts each Antitamper loop with area sensor and cover contact Control points for resistance monitoring
44. emote release via remote data transmission On request Main control PC incl Modem ISDN PC Software TwinComm Power pack 12VDC 500mA TwinXT 90 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 8 1 2 Network Connection On request Main control unit ETHERNET Protected area Armored door Network Connection Online logging of all events at the safe The control center or head office records and stores events centrally Centralized timer programs for all connected safes and their users Central access control release by the head office Alarm messages via the network to the control center or head office Easy to use management software with extensive analysis functions for the head office Version 1 08A 91 TwinLock 7220 Manual wrrrkorP Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 8 2 Technical Data Input Unit TwinControl Power supply Current consumption Dimensions Environment Protection class Input Unit FlatControl Power supply Current consumption Dimensions Environment Protection class Lock TwinLock Power supply Current consumption Dimensions Environment Protection class 9 VDC 6 x Mignon Alkaline 1 5V
45. en assistent Info Zeiprog i Zeitprog 2 Einstellungen Schl sser bersicht Protokoll Men simulator Kundendat_4 gt 01 01 2006 4 01 01 2006 01 01 2006 24 12 2006 4 01 01 2006 4 4 01 01 2006 26 12 2006 4 01 01 2006 4 Chipkarte lesen gt Chipkarte schreiben 4 01 01 2006 01 01 2006 4 4 01 01 2006 01 01 2006 4 01 01 2006 01 01 2006 4 4 01 01 2006 01 01 2006 01 01 2006 01 01 2006 e c N 4 01 01 2006 01 01 2006 01 01 2006 4 4 01 01 2006 01 01 2006 4 01 01 2006 01 01 2006 G a G u a u o E G G u u u ad u g u g u u ui 4 4 01 01 2006 01 01 2006 wiederkehrende Sondertage wenn Checkbox aktiviert Karte ist aktiviert und freigegeben Special days Special days are days where the system can not be unlocked all day 30 special days are available The special days are evaluated every time the unlocking procedure is performed This means that the unlocking procedure is cancelled when the unlocking is performed on days which are defined as special days Setting the checkmark will set a special day as a recurring special day This means that the system will be locked each year on this day and month The setting of special days can only be performed by the owner of the system code and is saved in the event log Factory setting 01 01 2006 Special days deactivated Recurrin
46. ent alarm was triggered during the code input at the TwinControl FlatControl device last code digit 1 The relay is triggered for 2 seconds All relay contacts are directed to the screw terminals Resistors for resistance monitored lines may be employed The Relay is used to arm or disarm the burglary alarm system All relay contacts are directed to the screw terminals Resistors for resistance monitored lines may be employed The relay is used to indicate the status of all locks in the system All relay contacts are directed to the screw terminals Resistors for resistance monitored lines may be employed 10 Version 1 08A TwinLock 7220 wrrrkorP MICROELECTRONICS Hochsicherheitsschl sser L sungen f r mehr Sicherheit 2 6 Chip Cards TwinCard WITTKOPP EINER MICROELECTRONICS Solutions for high TwinLock ID TwinCard code access Ws MICROELECTRONICS Solutions for higher security TwinLock ID TwinCard configuration WITTKOPP ff MICROELECTRONICS Solutions for higher security TwinLock ID TwinCard language TwinCard code access Chip card as physical code to disarm a BAS The code is changed continuously TwinCard configuration Chip card for the system configuration and the event log In cooperation the with PC software TwinComm the configuration can be imported or exported and the log can be read out TwinCard language
47. er of the system code and is saved in the event log Example User code 1 2 3 4 5 6 7 8 gt gt Alarm code 1 2 3 4 5 6 7 9 9 becomes 0 Version 1 08A 57 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 6 16 Write Log and Configuration to Chip Card Menu Navigation TwinLock TwinLock 21 05 09 12 00 Import Export TwinLock Select the menu item Import Export Import Export see menu plan 4 2 see above System code Enter system Code code System code Please wait Evaluate the entry Import Export Select data export Data c Export with the menu keys Insert the TwinCard configuration Data export Insert card TwinCard configuration Select Export configuration Data export Configuration Write data Data are written to the gt gt gt gt gt gt Data export Remove card Remove card The data can be read by means of the Configuration set TwinComm and can be processed further The data export procedure is stored in the event log 58 Version 1 08A TwinLock 7220 wrrrkorP WEZ MICROELECTRONICS Hochsicherheitsschl sser L sungen f r mehr Sicherheit 6 17 Read configuration from chip card Menu Navigation TwinLock TwinLock 21 05 09 12 00 Import Export TwinLock
48. figuration Data import Language Read data Data is read from the chip card gt gt gt gt gt gt into the system Data import Remove card Remove card The data import procedure is stored in the event log The new language is activated immediately after the card has been read 60 Version 1 08A TwinLock 7220 wrrrkorP WEZ MICROELECTRONICS Hochsicherheitsschl sser L sungen f r mehr Sicherheit 6 19 Install Change Locks in the System Menu Navigation TwinLock TwinLock Service System 21 05 09 12 00 Service System Install new lock System install new lock System code Code System code Please wait install new lock New lock Bus cable on Master codes Code kkk Serial number Please wait install new lock Lock 02 OK Select the menu item install new lock see menu plan 4 2 see above Enter system code Evaluate the entry install new lock Selection Re register change lock or change a lock change lock Select the lock to L k 01 be replaced clear ente Connect both bus cables of the according lock to TwinConnect and acknowledge with ENTER To allocate the serial number the master code of the new lock must be entered 1234567 8 The serial number is transferred to the lock Detect and initialize the lock Acknowledge the lock number Automatic return after 3 second
49. further unlock code when the four eye code is activated Enter a further unlock code when the six eye code is activated When time delay is activated Display of the remaining time delay After the time delay has expired the release time starts Within this time window a further unlocking code must be entered clear c gt erie After the system lock has been unlocked the system may be configured Version 1 08A 31 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl s MICROELECTRONICS Manual L sungen f r mehr Sicherheit 5 2 Locking a Lock TwinLock Select the menu item Lock close see menu plan 4 2 When several locks are available in the system select one lock When Forced Lock 01 Sequence is selected locks are automatically closed B For Lock amp Code user no Select the user number cear ente k k 0123456789 please wait close Lock locks please wait close lock closed 01 When the system lock 01 was locked the system can longer re configured system locked Automatic return after 3 seconds 32 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 5 3 Status Request of a Lock TwinLock Select the menu item St
50. g special day deactivated Attention To ensure proper functioning of the special days the correct setting of the date time and weekday is required The settings only apply once for the set date Version 1 08A 79 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 7 4 Programming the Blocking Time TwinComm TwinLock Datei Chipkarte Sprache Tools Men assistent Info Zeitprog 1 Zeitprog 2 Einstellungen Schl sser bersicht Protokoll Men simulator Kundendat_4 gt Chipkarte lesen mb E Chipkarte schreiben _ Blocking time It is possible to program a blocking time during which the system can not be unlocked The blocking time can have a duration of 2 months max The programming of this function can only be performed by the owner of the system code and is saved in the event log Factory setting Blocking time deactivated Attention To ensure proper functioning of the blocking time the correct setting of the date time and weekday is required 80 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 7 5 Programming Partial Blocking Times TwinComm Twinlock Datei Chipkarte Sprache Tools Men assistent Info Zeitprog 1 zeitprog 2 Einstellungen Schl sser bersicht Protokoll Men s
51. he BAS control may also for closed systems in this special case be deactivated via the system code Please note that this procedure will trigger an alarm as soon as the locks are opened TwinLock In the system menu first the key F2 then key 4 is pressed Now enter the system code More see Chapter 6 11 Activate Arming Device TwinAlarm In this case the arming device must be deactivated Version 1 08A 39 TwinLock 7220 WITTKOPP EINER ass Manual Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 6 Programming the System with the Control Unit The following functions and settings can be performed using the control unit Reprogram master and system codes Program user codes Delete a user code Display a programmed User code Activate deactivate code linkage Date Time Program unlocking delay Program silent alarm Activate lock I O TwinXT Program forced sequence Program parallel code Write configuration and log to chip card Read configuration from chip card Import new system language Some of these functions and all others can be implemented by means of the Configuration Set TwinComm 40 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 6 1 Reprogramming a Master System Code Menu Navigation TwinLock TwinLock Configuration
52. he system will be in an undefined state More functions Protection against locking the locks while the bolt system is open Constant self diagnosis of the bus lines and system components Log entry of all warning and error messages Validity check of entered times and dates Version 1 08A 23 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 3 6 Prevention Against Sabotage Input unit FlatControl The input unit in the unsecured area is secured by different measures Opening the case battery compartment is immediately detected and displayed until an authorized user unlocks the system lock properly A person standing next to the authorized user cannot watch the entering of the code A special film in the view window of the terminal prevents the reading of the display from a lateral position Besides that the opening code is not entered via the keyboard but via the arrow keys above a digit selection on the display After each entry of a digit the cursor will be displayed at a randomly selected new position Arming device TwinAlarm The arming device case is protected against unnoticed intrusion by means of a tamper switch and protection on all sides All sabotage and control lines to the BAS can be equipped with a defined line resistance Soldering spots for resistance supported performance control are available More functions All codes are
53. iately When programming the code you must see to the new unlocking code being checked repeatedly while the safe is open Do not use personal data when programming unlocking codes Loosing a master code can have very costly consequences 42 Version 1 08A TwinLock 7220 wrrrkorP WEZ MICROELECTRONICS Hochsicherheitsschl sser L sungen f r mehr Sicherheit 6 2 Programming and Reprogramming of a User Code Menu Navigation us TwinLock Configuration System 05 Configuration System User codes system usercodes usercodes programming lock 01 H o H 3 H 5 programming user no xx old M U code programming user no xx new usercodes code k k confirm code code k k usercodes please wait usercode xx saved Automatic return after 3 seconds User codes Select the menu item User Codes see menu plan 4 2 see above clear gt ente clear adi ente Select programming Select the lock Enter the user number Enter the old unlocking code user codes user code or master code 2000 OOOO OOO clear go ente Enter the user number of the user code to be programmed Enter the new unlocking code 6
54. imulator Kundendat 4 Wochen ochenpregramm ffnungszeitraum 1 ffnungszeitraum 2 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 x Montag Dienstag Mittwoch x Donnerstag Freitag Samstag lt of of of o Of of of of of ao oy of of of um Sonntag Teilversperrung 4 D a 5 0 5 of alo off ol Of 0 of of CO CO o zeit 1 Teilsperrzeit 2 Chipkarte schreiben Chipkarte lesen aktiv Montag Dienstag Mittoch Donnerstag Freitag Samstag Sonntag HIFI ololojo o ee t3 c2 c2 ujoj o I oro ojo oo Sperrzeit Datum Uhrzeit Start 26 03 2006 00 00 Stopp 31 03 2006 00 00 Karte ist aktiviert und freigegeben Partial blocking time Two time periods for each of the seven days of the week are available during which the system may be partially blocked The partial blocking is only designed for two lock operation Both locks are opened by entering a code Within the partial blocking time only lock 2 is closed lock 1 remains open
55. in the event log The following settings are reset to factory defaults Physical Codes 00 35 Inactive Input level for BAS low active Relay outputs Idle State Disarmed Notes The code cards must be re registered see 6 12 Register alarm user Version 1 08A 69 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 6 26 Version query of the Arming Device TwinAlarm Menu Navigation TwinLock TwinLock Service Alarm 21 05 09 12 00 Service Alarm Version control Select menu item Alarm version query Version control Version number is displayed Version control SW version Axx Automatic return after 5 seconds 22 clear gt ente Version query Every user can perform the version query The current TwinAlarm software version is displayed 70 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 6 27 Activate Parallel Code Menu Navigation TwinLock TwinLock Configuration System 21 05 09 12 00 Configuration System Parallel code System Parallel code System code Enter system code Code System code Please wait Evaluate the entry Parallel code Yes No Display of the current setting and selection of the new condition
56. k Menu Navigation TwinLock TwinLock Service Lock 21 05 09 12 00 Service Lock Reset Select the menu item Lock Reset tock see menu plan 4 2 see above Reset When several locks are available Reset in the system select one lock Lock 01 Enter the master code of the Master code selected lock Code Evaluate the entry Master code Please wait Reset Action completed Saved Automatic return after 3 seconds Lock reset The reset can only be performed by the owner of the system code and is saved in the event log The following settings are reset to factory defaults Master code 12345678 User code 01 35 Inactive Input Output Inactive The lock addresses i e the allocations are not reset A hardware reset can only be performed by removing the seal For this purpose the according lock must be sent to your service partner Version 1 08A 67 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 6 24 Lock Motor Service Menu Navigation TwinLock TwinLock Service Lock 21 05 09 12 00 Service Lock Motor service Lock Select the menu item Motor service Motor service see menu plan 4 2 see above Motor service When several locks are available Lock 01 in the system select one lock Master code Enter the master code of the
57. l sser MICROELECTRONICS L sungen f r mehr Sicherheit 6 21 Query of the Control Unit Version Menu Navigation TwinLock TwinLock Service System 21 05 09 12 00 Service System Version query System Select menu item System version query Version query see menu plan 4 2 see above Version number is displayed SW version Txx clear ente Automatic return after 5 seconds Version query Any user can perform the version query The current FlatControl software version is displayed Please note the version lists Version 1 08A 65 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 6 22 Version Query of the Locks Menu Navigation TwinLock TwinLock Service Lock 21 05 09 12 00 Service Lock Version control Lock Select menu item Lock version control Version control see menu plan 4 2 When several locks are available Lock 01 j in the system select one lock Version control SW version Sxx Version number is displayed Automatic return after 5 seconds Version query Any user can perform the version query The current TwinLock software version is displayed 66 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 6 23 Reset a Loc
58. larm 21 05 09 12 00 Configuration Alarm User display sc T Select menu item User display 4 2 System code Enter system code Code xx kkk System code Evaluate the entry Please wait User display Navigate through user numbers User 01 OK Cancel with ENTER CLEAR Display registered alarm user With this function the system master can check which physical codes TwinCard code access are currently registered This function can only be activated by the owner of the system code and is saved in the event log Version 1 08A 55 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 6 14 Remove BAS user Deregister Alarm User Menu Navigation TwinLock TwinLock Configuration Alarm 21 05 09 12 00 Configuration Alarm remove BAS user Alarm remove BAS user Select the menu item remove BAS user see menu plan 4 2 see above System code Code ke ek Hx Enter system code System code Please wait Evaluate the entry remove BAS user User 01 Select according user or card number Action completed remove BAS user Deleted Automatic return after 3 seconds Deregister alarm user The physical code of an alarm user is deleted in the arming device which means that this user can no longer arm disarm the system
59. luate the entry Master code Please wait Display current settings time delay Start the entry with ENTER Time 00 1 00 Enter the new end time time delay Time 04 Rel 05 Action completed time delay time delay saved deleted Automatic return after 3 seconds e E M M H w K Time Delay for Unlocking This function delays the unlocking procedure when the code is entered correctly The time is entered in minutes 00 99 A time delay can be entered for each lock Release time The release time is used to safeguard the time delay If a release time was programmed e g gt 00 a correct unlocking code must be entered after the time delay has expired to finally open the lock The release time is set in minutes 00 99 and specifies the period during which the user can re enter the unlocking code after the time delay has expired If no release was programmed 00 the lock will open without re entering the code after the time delay has expired The programming of this function can only be performed by the owner of the system code and is saved in the event log Factory setting Time 00 Rel 00 deactivated Version 1 08A 51 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 6 11 Activate Arming Device TwinAlarm Menu Navigation TwinLock TwinLock Configuration Alarm 21 05 09 12 00 Configuration Alarm
60. med This function can only be configured via the PC software TwinComm In this case the unlocking codes apply to 2 or 3 locks e g the user does no longer need to select a lock and he is not bound to a specific lock In all locks however the same codes must be programmed for the according users e g User 08 Code Lock 1 08080808 Code Lock 2 08080808 Or Code Lock 3 08080808 Version 1 08A 15 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit Keyboard entry A simplified code entry for programming processes can be defined to enter the code via the key pad The code entry via the menu keys for an unlocking process however is maintained The definition can only be performed by the system master This function can only be configured via the PC software TwinComm Silent alarm During a threatening situation a special alarm code may be entered when locks are opened and closed to trigger a silent alarm The alarm code consists of the normal user access code where the last number is increased by 1 9 switches to 0 The system now acts exactly like for the normal opening procedure for the user and the intimidator but at the same time a silent alarm signal is sent to the BAS Furthermore an individual opening time delay may be defined for the case of an alarm The lock can only be opened after the set waiting period has expired see also timer
61. nected to a TwinXT or TwinAlarm system depending on the system variant In idle state display off the door or bolt system switch is queried periodically Pressing the key will automatically lock the system Connection to TwinXT The following connections and settings must be performed Connect the switch at the terminals of the bolt system position switch see assembly instructions For a two lock system the terminals of the bolt system position switch must be bridged for lock 1 and 2 Activate TwinXT via the menu or the PC software Set forced sequence the menu or the PC software TwinComm Setting the switching status for the locking via PC software TwinComm Active low gt when the contact is closed gt System locks Active high gt when the contact is open gt System locks Setting Automatic locking with door switch via PC software TwinComm Optional Combination with partial blocking time via PC software TwinComm Connection to TwinAlarm The following connections and settings must be performed Connect the switch at the terminals of the bolt system position switch or the central contact see assembly instructions Activate TwinAlarm Set forced sequence the menu or the PC software TwinComm Setting Automatic locking with door switch via PC software TwinComm Setting the switching state for locking is omitted gt when the contact is closed gt System locks Opti
62. ng code being checked repeatedly while the safe is open Do not use personal data when programming unlocking codes Loosing a master code can have very costly consequences Enter system The system code is identical to the master code of lock 01 user ID 00 8 digit system code In addition to having lock master privileges the system master is also authorized for system programming The system code can not be deleted or deactivated User code Each lock has 35 user codes user ID 01 35 8 digit user code The user codes are programmed or deleted by the according master code A user can reprogram his her user code autonomously Otherwise the user only has an unlocking authorization A user code can be assigned the possibility for Quick unlocking quick unlocking code without time delay expiration see timer programs Status indicator for programmed user codes For each lock the programmed user codes can be displayed The programming status i e OK or NOK is displayed The display can only be activated by the according lock master 14 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit Unlocking amp Locking The unlocking is tied to at least one code entry This always takes place via the menu keys see prevention against sabotage Unlocking can be prevented by several functions timer programs Locking is us
63. ngen f r mehr Sicherheit Error messages Burglary alarm system could not be armed because BAS was perhaps not acknowledged The input BAS ready at the TwinAlarm is not set by the BAS so arming is disabled The selected EMA user number is not identical to the user number of the code card The code on the code card is wrong i e the code card is invalid No code card was logged in yet i e the BAS cannot be armed Version 1 08A 37 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 5 5 2 Disarming the Burglary Alarm System The system TwinLock 7220 Alarm can disarm a connected BAS using the arming device TwinAlarm The disarming procedure is linked to the unlocking procedure of the system lock lock 01 for the forced sequence for all locks and is enabled by entering the mnemonic code during the unlocking procedure plus the additionally required physical code TwinCard code access If an unlocking procedure is not possible due to an active timer program or the like no disarming will take place TwinLock Select the menu item Unlock open see menu plan 4 2 When several locks are available in the open system select one lock When Forced Sequence is selected lock 01 is unlocked first BAS user User no 01 lt Select the BAS user number card number aser oi Insert card into the control
64. nlocking delay Inactive Partial blocking Inactive System line TwinLock Lock with code Inactive Opening duress Inactive Parallel code Inactive Send log online Inactive Arming device Inactive Battery warning limit 7 0V Code linkage 1 user TwinXT Inactive Version 1 08A 63 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit Only the control unit is reset This means that all settings which are stored in the control unit are reset to factory defaults The locks are not reset during this procedure and therefore maintain their allocations After a control unit has been reset it is restarted The system sends a prompt for re registering System setup New system clear a Se ente To re integrate the existing locks into the system the menu item Terminal switch must be activated using the arrow keys System setup Switch to Terminal switch Acknowledge with Enter ner Select the number of locks available in the system Acknowledge with Enter Select the number of the control unit System setup Acknowledge with Enter Terminai No 01 lt Usually always 01 After all data is entered a system check is performend and the system is operational Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitssch
65. ock Low Batt The time is automatically switched at the last weekend in March and at the last weekend in October can only take place via a code entry Version 1 08A 83 TwinLock 7220 Manual Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit Automatic locking a door switch Manual locking after bolt system query TwinAlarm active Silent alarm BAS level Arming with code card BAS user 1 BAS user 2 System line Automatic locking with bolt system or door switch For this action the function TwinXT active must be programmed or TwinAlarm active Before the locking procedure the position of the bolt system is queried using a switch For this action the functions TwinXT active or TwinAlarm active must be programmed Activate TwinAlarm This function is required for the arming disarming of a BAS Activate silent alarm time delay 01 99 minutes BAS input and output level setting Factory setting at the lock low active Notes The levels must only be reprogrammed in special circumstances The factory setting should be applicable to all conventional burglary alarm systems From version T08 control unit 2 different code cards can be inserted Code card Code card Il Factory setting at the lock Code card It is not possible to use both card types in one system Allocating a BAS user number which is us
66. ocking process The unlocking process can be performed The entering of the quick unlocking code and the blocking period interruption are logged The owner of the quick unlocking code also has the opportunity to trigger a silent alarm Version 1 08A 19 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 3 3 Service Functions Event Log The latest 768 events programming processes hardware errors and certain status messages manipulation and sabotage attempts are logged in chronological order including date and time perhaps the user number The event log can be displayed online i e each log entry is immediately transmitted to a printer PC connected via TwinAlarm There is also the possibility to transfer the entire event memory to the TwinCard configuration Display and printing of the event memory take place with the PC software TwinComm The clear text display of events in the set language is identical to the messages at the control unit TwinControl FlatControl or with the messages in the PC software TwinComm Configuration import export An entire configuration profile can be swapped out to the chip card Twin Card Configuration This profile can then be edited with the PC software TwinComm and reimported or saved The above described event log is also written to the card and can be displayed printed and saved using TwinComm Syst
67. om each other and can therefore function individually Voltage monitoring When the power supply is applied or when the system recovers from energy saving mode the state of the battery system voltage is checked When the system falls below a set warning threshold an entry is made in the log and a message is displayed Press F2 to display the system voltage from the system menu TwinLock TwinLock battery 9 0V Low Batt Every time the system is restarted battery replacement or when the system is activated the battery voltage is measured and checked If the battery voltage falls below the set warning limit the message II Low Batt is displayed and also stored the event memory 22 Version 1 08A Hochsicherheitsschl sser MICROELECTRONICS TwinLock 7220 WITTKOPP EINER L sungen f r mehr Sicherheit Power Failure The FlatControl receives its power supply via each of the two bus cables When a voltage failure occurs an emergency current feed for the entire system is possible via a jack at the bottom of the keyboard For this an adapter cable 7237 101 0 and a 9 volt block battery alkaline type is required For the connection of the adapter cable see figure Real time clock The date and the time are generated by a specially buffered real time clock and will survive even if the system receives no current for several days If a real time clock still happens to be deleted t
68. onal Combination with partial blocking time via PC software TwinComm 74 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 7 Programming of the System with the PC Software TwinComm Solutions Tor TwinLock N ID b TwinCard configuration The following functions can be performed with the configuration software TwinComm General settings Silent alarm alarm delay TwinXT active Automatic switching to daylight savings time Quick unlocking code Four Six eye principle Lock after bolt system contact query Quick unlocking code System line Battery warning limit Parallel code Forced Sequence Timer Programs Weekly program Special days Blocking time Time delay release time Teilsperrzeit Managing functions Customer data e User data e Menu simulator and menu wizard Version 1 08A 75 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 7 1 General Operation Installation guidelines for the software can be found on the program CD Start screen TwinComm Datei Chipkarte Sprache Tools Men assistent Info Zeitprog 1 Zeitprog 2 Einstellungen Schl sser bersicht Protokoll Men simulator Kundendat 4 gt WITTKOPP WITTKOPP cawi INSYS Rep Chipkarte lesen gt Chipkarte schreiben Hochsi
69. p card TwinCard configuration Version 1 08A 77 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 7 2 Program the Weekly Program TwinComm TwinLock Datei Chipkarte Sprache Tools Men assistent Info Zeitprog 1 Zeitprog 2 Einstellungen Schl sser bersicht Protoko 26 03 2006 00 00 31 03 2006 00 00 Karte ist aktiviert und freigegeben Weekly program For the 7 weekdays 2 periods each are available during which the system can be unlocked The weekly program is evaluated every time the unlocking procedure is performed This means that the unlocking procedure is cancelled when the opening is performed during a time which is not within those two periods defined in the weekly program Green 00 00 00 00 Unlocking can take place all day Gray Unlocking can only take place during the specified period Red No unlocking procedure can be performed on this day Factory setting Mo Su 00 00 00 00 Weekly program deactivated 00 00 00 00 Attention To ensure proper functioning of the weekly program the correct setting of the date time and weekday is required 78 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 7 3 Programming of Special Days TwinComm TwinLock Datei Chipkarte Sprache Tools M
70. r contacts resistance monitoring etc Soldering terminals for the mounting of resistors for resistance monitored lines are available The inputs can be customized in various ways using jumpers In TwinAlarm the electronic keys chip cards as well as the input signals of the burglary alarm system are evaluated The TwinAlarm housing is protected against sabotage by the means of a tamper switch and protection on all sides and it is secured with a sealing adhesive label Version 1 08A 9 TwinLock 7220 wrrrkorP INEN Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit BAS Inputs BAS READY Prevents the BAS from being armed Customization by jumper and software DISARM BLOCK Prevents the BAS from being disarmed Customization by jumper and software RELEASE Prevents the unlocking of the locks customization by jumper and software ACKNOWLEDGEMENT Evaluates the arming acknowledgement of the BAS Other Inputs NO TIMEOUT CENTRAL CONTACT Outputs ALARM ARMED DISARMED STATUS Customization by jumper and software Enables the interruption of the timer programs weekly programs special days blocking time so that for example persons locked into the safe may be freed during an active timer program The central contact prevents the shutting of locks when the bolt system is open gt Bolt system contact The relay switches when a sil
71. r enables the blocking of individual menu items of the terminal to disable the selected functions at the terminal Version 1 08A 25 TwinLock 7220 WITTKOPP Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 4 Operation 4 1 Display and Control Elements of the Input Equipment LC Display Background lighting TWIN CONTROL TwinLock ID TwinCard code access Insertion of the chip card Chip at the bottom 26 Version 1 08A f v 0 2 WITTKOPP L sungen f r mehr Sicherheit 0 9 2 0 T E 0 mi 0 T g 2 Hochsicherheitsschl sser TwinLock 7220 4 2 Menu Navigation Jonuoo jasal WHEE Joyoul uoIsI8A yoo wepe sposissp e dsip 4 yoo mau uoIsien was s Jes Aejdsip sseinp SV ejqeue uneje B91A1aS plodxe yodu 499 921 198 9921198 AIOTUML zur xx NOOTUIML uus uneje
72. s Version 1 08A 61 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit Re registering replacing of locks Only the owner of the system code can re register or replace a lock This action is stored in the event log ATTENTION The system code is only queried if a lock is already registered in the system Only one individual lock can be re registered or replaced If there are more locks in the system this procedure must be repeated Each lock that is being re registered receives the next hightest lock number in the system 62 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 6 20 Reset the Input Unit Twin Control Flat Control Menu Navigation TwinLock TwinLock Service System 21 05 09 12 00 Service System Reset System Select the menu item System Reset Reset see menu plan 4 2 see above System code Enter system code Code System code Evaluate the entry Please wait Reset Action completed Saved Automatic return after 3 seconds System reset Only the owner of the system code can perform the system reset The following settings are reset to factory defaults Weekly program Inactive Quick unlocking code 09 Special days Inactive TwinCard code access Active Blocking time Inactive U
73. saved and evaluated within the secured area Log entry of all security relevant events Blocking times when a wrong code is entered repeatedly see code programs timer programs Configuration only possibly for unlocked systems after entering the system codes 3 7 Other Functions Automatic switching to daylight savings time System line freely configurable When the system is activated the company name is displayed for example System status indicator The condition of the individual locks can be queried 3 8 Certifications The TwinLock 7220 system is VdS approved for locks as BAS locking and arming devices classes 3 C 24 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 3 9 PC Support with Configuration Set TwinComm Basically the TwinLock 7220 system also works without PC support but using the software simplifies the configuration and enables easy reading of the event log The exchange of data with the lock system takes place with the chip card TwinCard configuration and the service function Import Export at the control unit Read out configuration profiles can be saved printed or modified and reimported All timer programs and system settings can be programmed When the system settings are read out the event log is also written to the chip card The protocol can be displayed and printed with TwinComm The menu manage
74. t Ino Each user of bersicht Protokoll Men simulator Kundendaten Benutzerdaten Benutzer bersicht the lock can be ums allocated a name which is also saved in the event log Karte ist aktiviert und freigegeben TwinComm Datei Chipkarte Sprache Tools Men assistent Info bersicht Protokoll Men simulator Kundendaten Benutzerdaten Benutzer bersicht overview can printed or saved for administrative Benutzer bersicht TwinLock purposes Benutzer bersicht TwinLock Schloss 1 Mastercode Hr Direktor BenutzerCode 1 Hr Meier BenutzerCode 3 Fr Huber BenutzerCode 4 Fr M ller Schloss 2 Mastercode 88 Version 1 08A TwinLock 7220 L sungen f r mehr Sicherheit 7 11 Customer Data Management TwinComm Datei Chipkarte Sprache Tools Men assistent Info Zeitprog 1 Zeitprog 2 Einstellungen Schl sser bersicht Protokoll MenUsimulator Kundendat 4 gt Fa Mustermann AG 1930 Musterhausen Hr Mustermann Customer data can be saved and archived for each programming This means that an individual configuration file can be created for each customer This file can be read also at a later date Version 1 08A 89 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 8 Appendix 8 1 Applications 8 1 2 Remote release TwinLock R
75. the menu item opening duress see menu plan 4 2 see above System code Code kk Enter system code System code Please wait Evaluate the entry 22 Display of the current setting Te and definition of the new condition opening duress Action completed Saved Automatic return after 3 seconds Forced Sequence Programming the function Opening duress determines the unlocking or locking sequence The system will only then be in an unlocked state when all locks are open It will be in a locked state when all locks are closed Opening sequence lock 1 lock 2 lock n system unblocked Locking sequence Lock n lock 2 lock 1 system locked The programming of this function can only be performed by the owner of the system code and is saved in the event log Factory setting No opening duress no forced sequence No 50 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit 6 10 Program Unlocking Time Delay Menu Navigation TwinLock TwinLock Configuration Lock 21 05 09 12 00 Configuration Lock Time delay Select the menu item time delay or see menu plan 4 2 see above time delay When several locks are available ioe OF in the system select one lock Enter the master code of the Master code selected lock Code Eva
76. trol unit serial number does not match the lock Please call customer service Version 1 08A 35 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit 5 5 Operation with a Burglary Alarm System BAS 5 5 1 Arming the Burglary Alarm System The system TwinLock 7220 can arm a connected BAS using the arming device TwinAlarm The arming may only occur when 1 The system lock is locked usually lock 1 for the forced sequence for all locks 2 At least one physical code chip card has been logged on 3 The connected BAS is activated TwinLock Arming using 04 05 09 21 06 the key F1 in the system menu BAS user Select the BAS user number user 01 lt chip card number user 01 When the function Arm amp Card card has been activated the chip card TwinCard code access is required user 01 4 for the arming procedure User 01 The BAS is now armed BAS armed an acoustic signal is emitted Automatic return after 3 seconds Note We recommend to activate the function Arm amp Card as otherwise the BAS could be armed by a non authorized person The BAS user numbers are only linked to the logged on chip cards and have nothing to do with the user numbers of the individual locks 36 Version 1 08A TwinLock 7220 wrrrkorP WEZ Hochsicherheitsschl sser MICROELECTRONICS L su
77. tz 03 04 06 Code Eingabe 1 Hr M ller 03 04 06 Motorfehler 03 04 06 Motorfehler 03 04 06 Motorfehler 18 03 04 06 Motorfehler 03 04 06 Manipulation 1 Hr Meier 03 04 06 Falscher Code 1 Hr Meier 03 04 06 Falscher Code Hr Meier 03 04 06 Falscher Code 1 User 35 03 04 06 Motorfehler 18 03 04 06 Motorfehler 03 04 06 Falscher Code Hr Meier 03 04 06 Falscher Code Hr M ller 03 04 06 Motorfehler 03 04 06 Motorfehler 03 04 06 Motorfehler 03 04 06 Motorfehler 03 04 06 Neustart 02 04 06 Daten Export 02 04 06 Code Eingabe Hr M ller 02 04 06 System entsperrt 02 04 06 Schloss auf 02 04 06 Code Eingabe User 0 02 04 06 Schloss aut 02 04 06 Unscharf 02 04 06 Code Eingabe j Hr Meier 02 04 06 Codekarte User 1 02 04 06 Scharf j User 1 02 04 06 EMA nicht bereit User 1 02 04 06 System versperrt 02 04 06 Schloss zu 02 04 06 Schloss auf Chipkarte lesen Chipkarte schreiben CHIPDRIVE micro Vorgang l uft 100 The following events are logged All unlocking and locking procedures and all code entries are logged Furthermore all configuration procedures and manipulation attempts are logged The log list can be printed on a connected printer or saved and archived in a file Use the button Update user to display the according user names after the log is being read if the users were entered
78. ually not tied to a code entry and is either initiated by the menu item Lock or by a switch which is connected to the lock Forced Sequence When a forced sequence is activated the locks can only be opened in a certain sequence lock 01 02 When locking the system the sequence is reversed The system is only unlocked and accessible for configuration and service after all locks have been opened Lock amp Code When this function is activated the locking process is tied to the entry of a valid code This means that the system can only be locked by authorized persons The user number is recorded in the log This function can only be configured via the PC software TwinComm Automatic lock with door switch The system can be locked automatically using a door switch or a bolt system contact which is either connected to a TwinAlarm or TwinXT system depending on the system variant This function can only be configured via the PC software TwinComm Code linkage For the entire system the function Four eye code or Six eye code can be programmed A lock can thus only be unlocked by entering 2 or 3 user codes respectively Programming can only be performed by the system master If a four eye or six eye code has already been programmed the system master can perform the programming only in connection with other users of lock 01 Parallel code For a 2 or 3 lock system the function parallel code can be program
79. unit insert card with the chip facing downward Codelinkage Unlocking see time delay for unlocking unlocking a lock See also Unlocking a Lock The BAS is now disarmed BAS disarmed an acoustic signal is emitted BAS user Remove code card remove card ee The lock is opened open lock open 01 After the system lock has been unlocked open the system may be configured system unlocked 38 Version 1 08A TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS L sungen f r mehr Sicherheit Attention The disarming procedure can only take place with the code card and the mnemonic code The BAS user numbers are only linked to the logged on chip cards and have nothing to do with the user numbers of the individual locks The BAS is disarmed before the locks are unlocked Remove the code card only when the system asks the user to do so Error messages The BAS could not be disarmed The input Disarm Block at TwinAlarm 15 set by the BAS so disarming is disabled The selected EMA user number is not identical to the user number of the code card Wrong card ID The code on the code card is wrong i e the code card is seve invalid Error code card Emergency shutdown of the BAS control If it is no longer possible to disarm the BAS control via TwinLock because the available code cards are faulty or other technical errors have occurred t
80. vated by themanufacturer When programming the code you must see to the new unlocking code being checked repeatedly while the safe is open i Do not use personal data when programming unlocking codes Version 1 08A 29 TwinLock 7220 Manual WITTKOPP Hochsicherheitsschl sser IN maa L sungen f r mehr Sicherheit 5 General Operation Processes TwinLock Open more locks in the system open lock XX BAS active and armed and lock 1 BAS user user 01 v user no 01 card in code entry user no 01 v 0123456789 code code entry Please wait 4 eye code chosse user number enter gt confirmation enter code with menue keys code entry user no 01 v 0123456789 Code code entry please wait 6 eye code yes choose lock confirm with enter with forced sequence lock 1 is automaticly chosen choose BAS user Nr enter gt confirmation insert card TwinLock ID TwinCard code access chosse user number enter gt confirmation enter code wtih menue keys chosse user number enter gt confirmation code entry user no 01 v 0123456789 code entry please wait code enter code wtih menue keys time delay
81. w user number User 01 card number clear 0 Bo ente User O1 Insert TwinCard code access Insert card User 01 Save setting Please wait TwinCard code access User 01 Remove card Remove TwinCard code access User 01 Action completed Automatic return after 3 seconds Register alarm user A mnemonic and a physical code are required to control the BAS The mnemonic code is realized the unlocking code of the lock The chip card is the physical code carrier The code is saved in the arming device and on the card Every time the system is disarmed the physical code is changed i e a new code is stored in the card to achieve a high level of security Version 1 08A 53 TwinLock 7220 WITTKOPP EINER ass Hochsicherheitsschl sser MICROELECTRONICS Manual L sungen f r mehr Sicherheit Use the function Register alarm user to allocate a physical code to a specific user The alarm function is only linked to lock 01 system lock Only the owner of the system code can create a new alarm user This action is stored in the event log Error messages sid Inserted chip card is invalid cannot be read 54 Version 1 08A Hochsicherheitsschl sser MICROELECTRONICS TwinLock 7220 WITTKOPP EINER ass L sungen f r mehr Sicherheit 6 13 Display Registered Alarm Users Menu Navigation TwinLock TwinLock Configuration A