4. Junior User Guidebook
Contents
1. Mechanical Specifications 348mm 170mm 78mm L H W About 1 5 kg Interval Period of Adjustment One year is recommended for the calibration interval period 84 www tmatlantic com 9 Appendix 9 Appendix Appendix A Enclosure Standard Accessories A pair of Passive probe 1 2 m 1 1 10 1 Ix CD PC link application software 1x Power cord up to the standards of the country in which it is used 1x USB cable 1x User Manual Appendix B General Care and Cleaning General Care Do not store or leave the instrument where the liquid crystal display will be exposed to direct sunlight for long periods of time Caution To avoid any damage to the instrument or probe do not exposed it to any sprays liquids or solvents Cleaning Inspect the instrument and probes as often as operating conditions require To clean the instrument exterior perform the following steps l Wipe the dust from the instrument and probe surface with a soft cloth Do not make any scuffing on the transparent LCD protection screen when clean the LCD screen Disconnect power before cleaning your Oscilloscope Clean the instrument with a wet soft cloth not dripping water It is recommended to scrub with soft detergent or fresh water To avoid damage to the instrument or probe do not use any corrosive chemical cleaning agent Warning Before power on again for operation it is required to confirm that the instrument has already
2. Fig 5 52 Set the network parameters of the oscilloscope How to Measure Automatically Press the Measure button to display the menu for the settings of the Automatic Measurements The oscilloscopes provide 20 parameters for auto measurement including Vpp Vmax Vmin Vtop Vbase Vamp Vavg Vrms Overshoot Preshoot Freq Period Rise Time Fall Time Delay A gt BF Delay A B Width Width Duty Duty That s 10 voltage and 10 time measurements in all The menu is displayed as Fig 5 53 59 www tmatlantic com 5 Advanced User Guidebook Fig 5 53 Measure Menu The Automatic Measurements menu is described as the following table Setting Tye Press F1 show the measure types Source cH oe the source CH2 Add Show all SS Show all the measures on the screen Add the selected measure types shown at the left bottom you could only add 8 types at most Removeall si Remove all the measures Remove Type Turn G knob select the types need to be deleted Remove a Remove the chosen measure type Measure The measured values can be detected on each channel simultaneously Only if the waveform channel is in the ON state the measurement can be performed The automatic measurement cannot be performed in the following situation 1 On the saved waveform 2 On the mathematical waveform 3 On the XY format 4 On the Scan format Measure the frequency the peak to peak voltage of the Channel
3. Bandwidth 30MHz Sample rate real time Up to 250MS s Dual channel 10K points on each channel for the Record length Autoscale function smart design body 8 inch high definition TFT display 800 x 600 pixels Built in FFT function Pass Fail Function optically isolated Pass Fail output Waveform record and playback VGA port optional Various triggering function USB LAN communication ports Built in Chinese and English help system Multiple language support A www tmatlantic com 4 Junior User Guidebook 4 Junior User Guidebook This chapter deals with the following topics mainly Introduction to the structure of the oscilloscope Introduction to the user interface How to implement the general inspection How to implement the function inspection How to make a probe compensation How to set the probe attenuation coefficient How to use the probe safely How to implement an auto calibration Introduction to the vertical system Introduction to the horizontal system Introduction to the trigger system 5 www tmatlantic com 4 Junior User Guidebook Introduction to the Structure of the Oscilloscope When you get a new type oscilloscope you should get acquainted with its front panel at first and the ADS 2031 2031V digital storage oscilloscope is no exception This chapter makes a simple description of the operation and function of the front panel of the ADS 2031 2031V_ oscilloscope enabling you to be fami
4. f _ ne pan mit End and store Caps l ESC Enter Switch between Close the keyboard capital and small How to Record Playback Waveforms Wave Record function can record the input current wave You can set the interval between recorded frames in the range of 1ms 1000s The max frame number reaches 1000 and you can get better analysis effect with playback and storage function Wave Record contains four modes OFF Record Playback and Storage Record To record wave according to the interval until it reaches the end frame set Record menu shows as follows OFF Close wave record function Record Set record menu Playback Set playback menu Storage Set storage menu End frame Turn the G knob to select the number of frames to Record mode record 1 1000 FrameSet Turn the G knob to select the interval between I l ea recorded frames 1ms 1000s Refresh Refresh DE during recording OFF Stop refreshing Operate Play Begin to record Stop Stop recording Note Both of the waveforms of Channel 1 and Channel 2 will be recorded If a Channel is turned off while recording the waveform of the channel is invalid in the playback mode 47 www tmatlantic com 5 Advanced User Guidebook 0 000ns 250KS s M 200us f 0 00mv Depth 1K Stop Fig 5 36 Wave Record Playback Play back the wave recorded or saved Playback menu shows as follows Setting Start frame Turn the G knob to select the
5. A AKTAKOM AKTAKOM ADS 2031 2031V Oscilloscopes User s Manual www tmatlantic com Table of Contents 1 General Safety CU UIT CIN CTI 2s caccencscxictassntecssusd cule savas dancesiesetectesscunetssd duicetseesestaeseenteskeseass I Za iS APC lerms and SV IMDOIS ssccznceccncisntescacensnecsndutontesenmdeeasednsanenatesdnacsedatonssenanscqebedseesseexanases Z 3 General Characteri slis sacavesaavacasssncedaneauneucconessssssvenesuesssacstanenepeaucsaveicasesurseusanareserosseqeeats 4 4 Junior User GuideDoOk soccnencicciacasaaveccunciuacsannsnoieensesseaesesaseatsaeasasoones veiav neaueaees tanndacseeseneua 5 Introduction to the Structure of the Oscilloscope ssscecccssssecccsssssecossssseccosssseccossssecesssssesessso 6 Pont E n ea E E EE E A E E 6 Riit FNS Pane eiee O EE E io eee q Pe P e E EAE E A A EA EE A A E S 8 Contool key and krob ATE dase E EA E 9 User Tiberi ace Introdicti on sssaaa oeaan sra aeeai 10 How to Implement the General Inspection ssssssscccrsssssssscccccssssssccccccssssssccsssessscsceseees 12 How to Implement the Function Inspection sssccscccsssssscccccsssssscccsscssssssccsscsssssscossees 12 How to Implement the Probe Compensation sssssesesosssececcssseecocossseesossseseccssssseceossssecesossseeeso 13 How to Set the Probe Attenuation Coefficient eesessssceccsssseecocssscecoossseseoosssseecesssseecsssssseso 14 How to USE the Probe SAtely senaniensddirn a Naaa 15 How
6. 3 Coupling Trigger coupling determines what part of the signal passes to the trigger circuit Coupling types include AC DC LF Reject and HF Reject AC AC coupling blocks DC components DC DC coupling passes both AC and DC components LF Reject LF Reject coupling blocks DC component and attenuates all signal with a frequency lower than 8 kHz HF Reject HF Reject coupling attenuates all signals with a frequency higher than 150 kHz 4 Holdoff Trigger holdoff can be used to stabilize a waveform The holdoff time is the oscilloscope s waiting period before starting a new trigger The oscilloscope will not trigger until the holdoff time has expired It provides a chance for user to check the signal in a short period and helps to check some complex signals such as AM waveform etc 37 www tmatlantic com 5 Advanced User Guidebook How to Operate the Function Menu The function menu control zone includes 8 function menu buttons Measure Acquire Utility Cursor Autoscale Save Display Help and 4 immediate execution buttons Autoset Run Stop Single Copy How to Implement Sampling Setup Press the Acquire button and the menu is displayed in the screen shown as Fig 5 25 Fig 5 25 ACQU MODE Menu The description of the Acqu Mode Menu is shown as follows Setting Sample __ Normal sampling mode Use to capture maximal and minimal samples Finding highest and lowest points Peak detect over adjacent
7. Press the F2 button and choose CH2 7 Press the F1 button again and turn the G knob to choose PK PK 8 Read the peak to peak voltages of Channel 1 and Channel 2 from the bottom left 73 www tmatlantic com 6 Demonstration of the screen See Fig 6 2 9 Calculate the amplifier gain with the following formulas Gain Output Signal Input signal Gain db 20xlog gain O 000ns 1 25M57s M 400us Depth 10K Fig 6 2 Waveform of Gain Measurement Example 3 Capturing a Single Signal It s quite easy to use Digital Oscilloscope to capture non periodic signal such as a pulse and burr etc But the common problem is how to set up a trigger if you have no knowledge of the signal For example if the pulse is the logic signal of a TTL level the trigger level should be set to 2 volts and the trigger edge be set as the rising edge trigger With various functions supported by our Oscilloscope user can solve this problem by taking an easy approach First to run your test using auto trigger to find out the closest trigger level and trigger type this helps user to make few small adjustments to achieve a proper trigger level and mode Here is how we achieve this The operation steps are as follows 1 Set the probe menu attenuation coefficient to 10X and that of the switch in the probe to 10X see How to Set the Probe Attenuation Coefficient on P14 2 Adjust the VOLTS DIV and SEC DIV knobs to set up a proper vertical and ho
8. Typical Acquisition real time Input coupling DC AC Ground Input impedance IMQ 2 in parallel with 10pF 5pF Probe attenuation 1X 10X 100X 1000X factor Input Max input voltage 400V PK PK DC AC PK PK Channel channel 50Hz 100 1 isolation 1OMHz 40 1 Time delay between 150ps channel typical Horizontal Sampling rate range Dual CH 5S s 125MS s System aah 5 Single CH 5S s 250MS s Interpolation sin x x Dual CH Max Record length lt Max sampling rate 10K Single CH Scanning speed Ans div 100s div S div a eee Sampling rate 100ppm relay time accuracy 8 www tmatlantic com 8 Technical Specifications Performance Characteristics Instruction Single Interval AT 1 interval time 100ppmxreading 0 6ns accuracy Average gt 16 DC 100MHz 1 interval time 100ppmxreading 0 4ns DC accuracy Average gt 16 3 rdg 0 05 div for AV average Waveform inverted ON OFF Cursor AV and AT between cursors Vpp Vmax Vmin Vtop Vbase Vamp Vavg Vrms Overshoot Preshoot Freq Automatic Period Rise Time Fall Time Delay A B Delay A B t Width Width Duty Duty Waveform Math Fa a FFT Waveform storage Bandwi Full bandwidth dth Phase Measurement Lissajous fi aad differen 3 degrees Ce Communication USB2 0 USB for file storage LAN port port VGA port or RS 232 Optional 82 www tmatla
9. 17 Edge trigger menu Edge menu list Settings Single Mode Set vertical channel trigger type as edge trigger Channel 1 as trigger signal Source Channel 2 as trigger signal External trigger as trigger signal 1 5 of the external trigger signal as trigger signal Block the direct current component Allow all component pass Couple Block the high frequency signal only low frequency component pass Block the low frequency signal only high frequency component pass Slope Trigger on rising edge Trigger on falling edge Acquire waveform even no trigger occurs Mode Normal Acquire waveform when trigger occurs Single When trigger occurs acquire one waveform then stop Holdoff 100ns 10s turn G knob to set time interval before Holdoff another trigger occur Reset Set Holdoff time as default value 100ns 2 Video Trigger Choose video trigger to trigger on fields or lines of NTSC PAL or SECAM standard video signals Trig menu refer to Fig 5 18 Fig 5 18 Video trigger menu 34 www tmatlantic com 5 Advanced User Guidebook Video menu list MENU SETTING INSTRUCTION Single Mode Set vertical channel trigger type as video trigger Select CH1 as the trigger source Select CH2 as the trigger source Source The external trigger input 1 5 of the external trigger source for increasing range of level NTSC Modu PAL Select video modulation SECAM Line Synchronic trigger in video line Field Synchronic trigger in video fie
10. CH1 and the mean the RMS of the Channel CH2 following below steps Press the Measure button to show the automatic measurement function menu Press the H1 button to display the Add menu Press the F2 button and choose CH1 as the source oo ee Press the F1 button the type items will display at the left of screen and turn the 60 www tmatlantic com 5 Advanced User Guidebook G knob to choose Period 5 Press the F4 button the period options added completes 6 Press the F1 button again the type items will display at the left of screen and turn the G knob to choose Freq N Press the F4 button the frequency added completes finish setting of CH1 QO Press the F2 button and choose CH2 as the source 9 Press the F1 button the type items will display at the left of screen and turn the G knob to choose Mean 10 Press the F4 button the Mean added completes 11 Press the F1 button the type items will display at the left of screen and turn the G knob to choose PK PK 12 Press the F4 button the PK PK added completes finish setting of CH2 The measured value will be displayed at the bottom left of the screen automatically see Fig 5 54 0 000ns 1 25MS s M 400us f 0 00m Depth 10K Fig 5 54 automatic measurement The automatic measurement of voltage parameters The ADS 2031 2031V oscilloscopes provide automatic voltage measurements including Vpp Vmax Vmin Vavg Vamp Vrms Vtop Vbase Ov
11. DC level The diagram of the oscilloscope ground wire connection Probe Oscilloscope Electrical Outlet Signal Input Power Cord Ground Clip The diagram of the ground wire connection when the battery powered oscilloscope is connected to the AC powered PC through the ports Probe Oscilloscope PC Electrical Outlet Battery power USB VGA COM LAN Cable Ground Clip It is not allowed to measure AC power when the oscilloscope is AC powered or when the battery powered oscilloscope is connected to the AC powered PC through the ports Warning To avoid fire or electrical shock when the oscilloscope input signal connected is more than 42V peak 30Vrms or on circuits of more than 4800VA please take note of below items Only use accessory insulated voltage probes and test lead Check the accessories such as probe before use and replace it if there are any damages Remove probes test leads and other accessories immediately after use Remove USB cable which connects oscilloscope and computer Do not apply input voltages above the rating of the instrument because the probe tip voltage will directly transmit to the oscilloscope Use with caution when the probe is set as 1 1 Do not use exposed metal BNC or banana plug connectors Do not insert metal objects into connectors 3 www tmatlantic com 3 General Characteristics 3 General Characteristics Y VV VV VV WV VV VV WV WV
12. For correct measurements the attenuation coefficient settings in the operating menu of the Channel should always match what is on the probe see How to Set the Probe Attenuation Coefficient on P14 If the attenuation coefficient of the 21 www tmatlantic com 5 Advanced User Guidebook probe is 1 1 the menu setting of the input channel should be set to X1 Take the Channel 1 as an example the attenuation coefficient of the probe is 10 1 the operation steps is shown as follows 1 Press the CH1 MENU button to show CH1 SETUP menu 2 Press the H3 menu selection the Probe menu will display at the right of the screen then press the F2 button to select X10 for the probe The Fig 5 3 illustrates the setting and the vertical scale factor when the probe of the attenuation coefficient of 10 1 is used 0 000ns 12 5MS s f 156v Depth 100K Fig 5 3 Regulation of the Attenuation Ratio of the Probe A list of the probe attenuation coefficient and the corresponding menu settings 10 1 100 1 X100 Attenuation Coefficient of the Probe Corresponding Menu Setting 1000 1 X1000 3 To invert a waveform Waveform inverted the displayed signal is turned 180 degrees against the phase of the earth potential Taking the Channel for example the operation steps are shown as follows 1 Press the CH1 MENU button to show the CH1 SETUP menu 2 Press the H2 menu selection button and select ON for Inverted item The w
13. VOLTS DIV knob control voltage scale of CH1 CH2 Horizontal control area with 1 key and 2 knobs HORIZONTAL POSITION knob control trigger position SEC DIV control time base HORIZ MENU key refer to horizontal system setting menu Trigger control area with 3 keys and 1 knob TRIG LEVEL knob is to adjust trigger voltage Other 3 keys refer to trigger system setting 9 www tmatlantic com 4 Junior User Guidebook User Interface Introduction 1 2 34 O1 O N ee oa a 7 8 9 10 11 12 19 18 17 16 15 Fig 4 5 Illustrative Drawing of Display Interfaces Waveform Display Area The state of trigger including Auto Automatic mode and acquire waveform without triggering Trig Trigger detected and acquire waveform Ready Pre triggered data captured and ready for a trigger Scan Capture and display the waveform continuously Stop Data acquisition stopped The purple T pointer indicates the horizontal position for the trigger The pointer indicates the trigger position in the internal memory The two yellow dotted lines indicate the size of the viewing expanded window It shows present triggering value and displays the site of present window in internal memory It shows setting time see Config on P50 It indicates that there is a U disk connecting with the oscilloscope The waveform of CH1 The purple pointer shows the trigger level position for CH1 The positions of two purple dotte
14. Window Setting and the Window Expansion Introduction to the Trigger System As shown in Fig 4 13 there are one knob and three buttons make up TRIGGER CONTROLS The following practices will direct you to be familiar with the setting of the trigger system gradually 17 www tmatlantic com 4 Junior User Guidebook Fig 4 13 Trigger Control Zone Press the Trigger Menu button and call out the trigger menu With the operations of the menu selection buttons the trigger setting can be changed Use the TRIG LEVEL knob to change the trigger level setting By rotating the TRIG LEVEL knob the trigger indicator in the screen will move up and down With the movement of the trigger indicator it can be observed that the trigger level value displayed in the screen changes accordingly PS Turning the TRIG LEVEL knob can change trigger level value and it 1s also the hotkey to set trigger level back to 0 Press the button 50 to set the trigger level as the vertical mid point values of the amplitude of the trigger signal Press the Force button to force a trigger signal which is mainly applied to the Normal and Single trigger modes 18 www tmatlantic com 5 Advanced User Guidebook 5 Advanced User Guidebook Up till now you have already been familiar with the basic operations of the function areas buttons and knobs in the front panel of the oscilloscope Based the introduction of the previous Chapter the user shou
15. YT mode and AUTO triggering 4 At the mode of Autoscale DSO is always set as DC coupling with AUTO 69 www tmatlantic com 5 Advanced User Guidebook triggering In this case making Triggering or Coupling settings have no effect 5 At the mode of Autoscale if adjust the vertical position voltage division trigger level or time scale of CH1 or CH2 the oscilloscope will turn off Autoscale function To back to Autoscale press Autoset 6 Turn off the submenu at the Autoscale menu the Autoscale is off and turn on the submenu still enters into the function 7 When video triggering the horizontal time scale is 50us If one channel is showing edge signal the other channel 1s showing video one the time scale refers to 50us as video one as standard 8 While the Autoscale is working settings below will be made forcibly 1 The DSO will switch from non main time base to main time base status 2 The DSO will switch to Peak detection mode if it is in Average mode How to Use Built in Help 1 Press Help button the catalog will display in the screen 2 Press H1 or H2 to choose help topic or just turn the G knob to choose 3 Press H3 to view the details about the topic or just press the G knob 4 Press H5 to exit the help or just do other operations How to Use Executive Buttons Executive Buttons include Autoset Run Stop Single Copy Autoset It s a very useful and quick way to apply a set of pre set functions to t
16. always be used so it 1s suggested to set it to the value above 2000 Here we set it to 3000 o Ports sett ings P Connect using ME Y e ee TPi92 168 1 72 gt porti 2000 Custom USE Transfer Instructions Some Types can choose to get bin bmp or deep memory data faveF orm Image Hi zh Memory Depth Get Image File bmp Setting Keep Getting Delay ims 2000 C Save data file automatically to below directory For there is a limit mmber of files in one single directory of Windows File System FATI6 FATS2 HIFS m the mmber of files to be saved 15 not certain 1t 15 recommended to choose a directory in NIFS disk drive turn off the storage channels in device and use short directory path to save more files Fig 5 51 Set the network parameters of the Oscilloscope Software 58 www tmatlantic com 5 Advanced User Guidebook 4 Set the network parameters of the oscilloscope In the oscilloscope press the Utility button and press H1 button turn the G knob to select the LAN Set press the H2 button the set menu is displayed on the right Set the IP and the Port to the same value as the Ports settings in the software in step 3 The Netgate and Net mask should be set according to the router Press the H3 button to select Save set it prompts reset to update the config After resetting the oscilloscope if you can get data normally in the oscilloscope software the connection is successful
17. been dried completely avoiding any electrical short circuit or bodily injury resulting form the moisture 85 www tmatlantic com
18. current coupling indicates AC coupling indicates GND coupling It is cursor measure window showing the absolute values and the readings of the two cursors The yellow pointer shows the grounding datum point zero point position of the waveform of the CH2 channel If the pointer is not displayed it shows that this channel is not opened The red pointer indicates the grounding datum point zero point position of the waveform of the CH1 channel If the pointer is not displayed it shows that the channel is not opened 11 www tmatlantic com 4 Junior User Guidebook How to Implement the General Inspection After you get a new ADS 2031 2031V oscilloscope it is recommended that you should make a check on the instrument according to the following steps 1 Check whether there is any damage caused by transportation If it is found that the packaging carton or the foamed plastic protection cushion has suffered serious damage do not throw it away first till the complete device and its accessories succeed in the electrical and mechanical property tests 2 Check the Accessories The supplied accessories have been already described in the Appendix B Accessories of this Manual You can check whether there is any loss of accessories with reference to this description How to Implement the Function Inspection Make a fast function check to verify the normal operation of the instrument according to the following steps 1 C
19. intervals It is used for the Sample detection of the jamming burr and the possibility of reducing the confusion Average 4 16 64 128 It is used to reduce the random and don t care noises with the optional number of averages Change the ACQU Mode settings and observe the consequent variation of the wave form displayed 38 www tmatlantic com 5 Advanced User Guidebook 0 000ns 12 5MS s M 500us _f 0 00mv Depth 100K Fig 5 26 Peak Detect mode under which the burrs on the falling edge of the square wave can be detected and the noise is heavy 0 000ns age HE 12 5M8 7s M 500us Depth 100K Fig 5 27 Normal ACQU Mode display in which no burr can be detected 39 www tmatlantic com 5 Advanced User Guidebook 0 000ns 12 5MS s M 500us Depth 100K Fig 5 28 The displayed waveform after the noise is removed under the Average Mode in which the average number of 16 is set How to Set the Display System Press the Display button and the menu displayed in the screen is shown as Fig 5 29 Fig 5 29 Display Set Menu The description of the Display Set Menu is shown as follows Setting Dots Only the sampling points are displayed Type Vect The space between the adjacent sampling points in the display is filled with the vector form OFF 1 second 2 seconds Turn the G knob to set the persistence time Persist 5 seconds Infinity Clear the persistence XY Mode on Turn on the XY displ
20. it detects a trigger it will acquire enough data continuously to draw the waveform on right of trigger point Trigger control area consists of 1 knob and 3 menu keys TRIG LEVEL The knob that set the trigger level press the knob and the level will be cleaned to Zero 50 The instant execute button setting the trigger level to the vertical midpoint between the peaks of the trigger signal Force Force to create a trigger signal and the function is mainly used in Normal and Single mode Trigger Menu The button that activates the trigger control menu Trigger Control Single trigger Use a trigger level to capture stable waveforms in two channels simultaneously Single trigger has four modes edge trigger video trigger slope trigger and pulse trigger Edge Trigger It occurs when the trigger input passes through a specified voltage level with the specified slope Video Trigger Trigger on fields or lines for standard video signal Slope Trigger The oscilloscope begins to trigger according to the signal rising or falling speed Pulse Trigger Find pulses with certain widths The four trigger modes in Single Trigger are described respectively as follows 1 Edge Trigger An edge trigger occurs on trigger threshold value of input signal Select Edge trigger mode to trigger on rising edge or falling edge The Edge Trigger Menu is shown as Fig 5 17 33 www tmatlantic com 5 Advanced User Guidebook Ea Fig 5
21. line to connect the oscilloscope with a router the LAN port of the oscilloscope is in the right side panel the computer should be connected to the router too Set the network parameters of the computer Since the oscilloscope can not support obtaining an IP address automatically you should assign a static IP address The Default gateway and Subnet mask should be set according to the router Here we set the IP address to 192 168 1 71 Subnet mask is 255 255 255 0 Default gateway is 192 168 1 1 57 www tmatlantic com 5 Advanced User Guidebook Internet Protocol TCP IP Properties General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate F settings Obtain an IF address automatically IP address Subnet mask T2552 5 Defaut gateway r5 ai ARIC p m pm samem m Dpotain UNS Server adi Use the following ONS server addresses Prefered DNS server t Be Se Fig 5 50 Set the network parameters of the computer 3 Set the network parameters of the Oscilloscope Software Run the software on the computer choose the Ports settings of the Communications menu item Set Connect using to LAN About the IP the first three bytes is same as the IP in the step 2 the last byte should be different Here we set it to 192 168 1 72 The range of the port value is 0 4000 but the port which under 2000 is
22. multiple X 10 Taking the additive operation between Channel 1 and Channels 2 for example the 24 www tmatlantic com 5 Advanced User Guidebook operation steps are as follows 1 Press the Math button to bring up the Wfm Math menu 2 Press the H1 button and call out the Dual Wfm Math menu The menu will display at the left of the screen 3 Press the F1 menu selection button and choose CH1 for Factor 4 Press the F2 menu selection button and choose 5 Press the F3 menu selection button and choose CH2 for Factor2 The green calculated waveform M is displayed in the screen 1 25MS s M 400us 0 00m Depth 10K Fig 5 7 Waveform resulted from CH1 CH2 Using FFT function The FFT fast Fourier transform math function mathematically converts a time domain waveform into its frequency components It is very useful for analyzing the input signal on Oscilloscope You can match these frequencies with known system frequencies such as system clocks oscillators or power supplies FFT function in this oscilloscope transforms 2048 data points of the time domain signal into its frequency components mathematically and the final frequency contains 1024 points ranging from OHz to Nyquist frequency Taking the FFT operation for example the operation steps are as follows l 2a 3 4 Press the Math button and call out the Math menu Press the H2 button and call out the FFT menu Press the F1 button to choose C
23. number of start frame to playback 1 1000 End frame Turn the G knob to select the number of end frame Playback Mode to playback 1 1000 FrameSet Cur frame Turn the G knob to select the number of current frame to playback 1 1000 Interval Turn the G knob to select the interval between played back frames 1ms 1000s Play mode Loop Play back the wave continuously Once Play back the wave just one time Operate Play Begin to recone Stop Stop recording 48 www tmatlantic com 5 Advanced User Guidebook Startframe End frame 50 Cur frame Interval 100ms Bev 2ni 250KS s _f 0 00mv Frameset Record Playback Loop OncefPlay Stop Fig 5 37 Wave Playback Storage Save the current wave according to the start frame and end frame set Storage menu shows as follows Turn the G knob to select the number of start frame Storage Start frame to store 1 1000 Mode Turn the G knob to select the number of end frame to store 1 1000 Save fo Save the waveform record file to the internal memory Load fo Load the waveform record file from the memory Savemode Frame Set End frame Startframe End frame 250KS s _f 0 00mv Depth 1K Type Mode Frameset save Load Record storage Fig 5 38 Wave Storage 49 www tmatlantic com 5 Advanced User Guidebook To use wave record function do as follows 1 2 3 4 5 6 7 8 9 Press Save button Press H1 button turn
24. serial number showing e Display Press the Utility button and turn the G knob to select the Display to go to the following menu Display te Fig 5 40 Display Menu The description of Display Menu is shown as the follows Setting 5s 50s OFF Set the disappear time of menu GH e Adjust Press the Utility button and turn the G knob to select the Adjust to go to the following menu Fig 5 41 Adjust Menu The description of Adjust Menu is shown as the follows Setting Self Cal aaa Carry out the self calibration procedure Defalt Call out the factory settings 51 www tmatlantic com 5 Advanced User Guidebook Do Self Cal Self Calibration The self calibration procedure can improve the accuracy of the oscilloscope under the ambient temperature to the greatest extent If the change of the ambient temperature is up to or exceeds 5 C the self calibration procedure should be executed to obtain the highest level of accuracy Before executing the self calibration procedure disconnect the probe or wire and the input connector Press the Utility button Then press the H1 button and the function menu will display at the left of the screen turn the G knob to choose Adjust and then press the H2 button to choose Self Cal entering the self calibration procedure of the instrument Autocalibration Remove all probes cables from CH1l CH2 Press lt Auto calibration gt for Calibration Press any ke
25. the G knob to choose Record Press H2 button In the Mode menu press F2 button to choose Record Press H3 button In the Frame Set menu press F1 button and turn the G knob to set End frame press F2 button and turn the G knob to select the interval between recorded frames Press H4 button choose whether to refresh the wave when recording Press H5 button to start recording Press H2 button In the Mode menu press F3 button to enter the Playback mode Set the frame range and Playmode Then press H5 button to play To save the wave recorded press H2 button In the Mode menu press F4 button to choose Storage then set the range of frames to store press H4 button to save To load the waveform from the internal memory press Load and then enter playback mode to analyze the wave How to Implement the Auxiliary System Function Setting e Config Press the Utility button and turn the G knob to select Config to go to the following menu Fig 5 39 Configuration Menu The description of Configuration Menu is shown as the follows 50 www tmatlantic com 5 Advanced User Guidebook Setting Chinese Choose the display language of the operating system Language English Others Display on On Off the date display Set Time Setting Hour Minute Day Month Setting Date Month Lock all keys Unlock method press 50 KeyLock button in trigger control area then press Force button repeat 3 times About Version number and
26. turning the HORIZONTAL POSITION knob in the horizontal control area in the panel you can change the horizontal triggering position to obtain the negative delay making an easy observation of the waveform before the burr occurs see Fig 6 3 0 000ns 62 5MS s M 100us Depth 100K E5 Fig 6 3 Capturing a Single Signal 75 www tmatlantic com 6 Demonstration Example 4 Analyze the Details of a Signal Noise is very common inside most of the electronic signal To find out what s inside the noise and reduce the level of noise is very important function our oscilloscope 1s capable to offer Noise Analysis The level of noise sometime indicates a failure of electronic circuit The Peak Detect functions acts an important role to help you to find out the details of these noise Here is how we do tt 1 Press the Acquire button to display the Acquire menu 2 Press the H1 button to display ACQU Mode menu 3 Press the F2 button to choose Peak detect The signal displayed on the screen containing some noise by turning on Peak Detect function and changing time base to slow down the incoming signal any peaks or burr would be detected by the function See Fig 6 4 O0 000ns 12 5M5 7s M 500us f 0 00mv Depth 100K Fig 6 4 Signal with Noises Separate Noises from the Signal When focusing on signal itself the important thing is to reduce the noise level as lower as possible this would enable user to have more details ab
27. 3000 o Ports sett ings P Connect using ME Y e ee TPi92 168 1 72 gt porti 2000 Custom USE Transfer Instructions Some Types can choose to get bin bmp or deep memory data faveF orm Image Hi zh Memory Depth Get Image File bmp Setting Keep Getting Delay ims 2000 C Save data file automatically to below directory For there is a limit mmber of files in one single directory of Windows File System FATI6 FATS2 HIFS m the mmber of files to be saved 15 not certain 1t 15 recommended to choose a directory in NIFS disk drive turn off the storage channels in device and use short directory path to save more files Fig 5 48 Set the network parameters of the Oscilloscope Software 56 www tmatlantic com 4 5 Advanced User Guidebook Set the network parameters of the oscilloscope In the oscilloscope press the Utility button and press H1 button turn the G knob to select the LAN Set press the H2 button the set menu is displayed on the right Set the IP and the Port to the same value as the Ports settings in the software in step 3 Press the H3 button to select Save set it prompts reset to update the config After resetting the oscilloscope if you can get data normally in the oscilloscope software the connection is successful Fig 5 49 Set the network parameters of the oscilloscope How to connect with the computer through a router 1 2 Connection Use a LAN
28. For example to trigger from an external clock or with a signal from another part of the test circuit The EXT EXT 5 trigger sources use the external trigger signal connected to the EXT TRIG connector Ext uses the signal directly it has a trigger level range of 0 6V to 0 6V The EXT 5 trigger source attenuates the signal by 5X which extends the trigger level range to 3V to 3V This allows the oscilloscope to trigger on a larger signal 2 Trigger Mode The trigger mode determines how the oscilloscope behaves in the absence of a trigger event The oscilloscope provides three trigger modes Auto Normal and Single Auto This sweep mode allows the oscilloscope to acquire waveforms even when it does not detect a trigger condition If no trigger condition occurs while the oscilloscope is waiting for a specific period as determined by the time base setting it will force itself to trigger Normal The Normal mode allows the oscilloscope to acquire a waveform only when it is triggered If no trigger occurs the oscilloscope keeps waiting and the previous waveform if any will remain on the display Single In Single mode after pressing the Run Stop key the oscilloscope waits for trigger While the trigger occurs the oscilloscope acquires one waveform then stop Single In Single mode after pressing the Run Stop key the oscilloscope waits for trigger While the trigger occurs the oscilloscope acquires one waveform then Stop
29. HI as the source Press F2 button the windows item will display at the left of the screen turn the G knob to select Window including Rectangle Hamming Hanning and Blackman 25 www tmatlantic com 5 Advanced User Guidebook 5 Press F3 button to choose the Format including dB Vrms 6 Press F4 button the zoom window will display at the left of the screen turn the G knob to zoom in or out the wave of the multiple including x1 x2 x5 x10 To select the FFT window m There are four FFT windows Each one has trade offs between frequency resolution and magnitude accuracy What you want to measure and your source signal characteristics help you to determine which window to use Use the following guidelines to select the best window Best solution for frequency worst for magnitude Best type for measuring the frequency spectrum of nonrepetitive signals and measuring frequency components near DC Recommend to use for Rectangle Transients or bursts the signal level before and after the event are nearly equal Equal amplitude sine waves with frequencies those are very close Broadband random noise with a relatively slow varying spectrum Better solution for magnitude than Rectangle and good for frequency as well It has slightly better frequency resolution than Hanning Recommend to use for Hamming Sine periodic and narrow band random noise Transients or bursts where the signal levels before and after the even
30. Recall a Wavell ofiii sessies r a ie n aa r ea e EE 44 How to Record Playback Waveforms occicicicsssctu aneceisohasoned scndedeiunstedeecedadaatvexshuwasbsdedansadaredacadedaaawenncdesesades 47 How to Implement the Auxiliary System Function Setting cccccccccccccccececessesssssccsseeeeeeeeeeeeseeeeeeeeas 50 How to Measure A tomaticall ysics aia E aa deanna desea aaia 59 Howto Measure wiii CUSO aopn E EE E ES 63 How to Use Autoscale scnccccccicoseeelacnenecececasaxnnadeseueuassadandisnhullbcensesteeueestecessateddduwsbessseensententsdecsssatacedentecens 68 1 www tmatlantic com How to Use Built in FIG os csessssacdecincn cass tanttecwasasnSeedostatde a aa aiaa TEANA 70 HOW to Use Exec tive UUONS sss ciscssscssaranotisemnsaniosseissanaounaanaseagadadabatnogecsaiadesaiieadcaabadnasoatscasionsweageiabebsdes 70 O DI CINOTIS ONOI iiien EE EE EE E E 72 Example 1 Measurement a Simple Signal sssssssscececcccssssssecsceooscssssescecocosssssssecessesssssssssee 72 Example 2 Gain of a Amplifier in a Metering Circuit eeesecoosssssseececccocsssseseseseocossssssseee 73 Examples Capturing a Sinple Sinab sasien a 74 Example 4 Analyze the Details of a Signal sssssscececcocssssssecscceosssssssscecoccsssssssecesecossssssssee 76 Example 5 Application of X Y Function ccssccccsssesssssccsssessssccccsssessencccsssessesccccscessssscees dd Example 6 Video Siem al PriG GG k siscsaicsseiscewsaessasiesaeniacssnie
31. adjust the main window The display in the screen is shown as Fig 5 14 30 www tmatlantic com 5 Advanced User Guidebook bsos ooo DPP lee en ee ee ee A s s I o M s y o 12 5MS s M 500us oe Depth 100K oriom ECE Fig 5 14 Main Time Base Set Window Press the H2 menu selection button and choose Set The screen will show a window area defined by two cursors Use the HORIZONTAL POSITION and SEC DIV knobs to adjust the horizontal position and size of this window area In FFT mode Set menu is invalid See Fig 5 15 O s am LC Oe a aans ee o ee a aa o E E E a an O A E E o e nana O S L 12 5M57s M SO0us W 100us Depth 100K CD 8 Mein Set ane Fig 5 15 Window Setting Window Expansion Press the H3 menu selection button and choose Zoom As a result the window area defined by two cursors will be expanded to the full screen size see Fig 5 16 31 5 Advanced User Guidebook S M 500us W 100us Depth 100K 12 5MS Fig 5 16 Zoom Window 32 www tmatlantic com 5 Advanced User Guidebook How to Set the Trigger System Trigger determines when DSO starts to acquire data and display waveform Once trigger is set correctly it can convert the unstable display to meaningful waveform When DSO starts to acquire data it will collect enough data to draw waveform on left of trigger point DSO continues to acquire data while waiting for trigger condition to occur Once
32. as 10X and that of the switch in the probe as 10X see How to Set the Probe Attenuation Coefficient on P14 and connect the probe with the CH1 channel If a probe hook tip is used ensure that it keeps in close touch with the probe Connect the probe tip with the signal connector of the probe compensator and connect the reference wire clamp with the ground wire connector of the probe connector and then press the button Autoset 2 Check the displayed waveforms and regulate the probe till a correct compensation is achieved see Fig 4 7 and Fig 4 8 13 www tmatlantic com 4 Junior User Guidebook Overcompensated Compensated correctly Under compensated Fig 4 7 Displayed Waveforms of the Probe Compensation 3 Repeat the steps mentioned if needed Fig 4 8 Adjust Probe How to Set the Probe Attenuation Coefficient The probe has several attenuation coefficients which will influence the vertical scale factor of the oscilloscope To change or check the probe attenuation coefficient in the menu of oscilloscope 1 Press the function menu button of the used channels CH1 MENU or CH2 MENU 2 Press H3 button to display the Probe menu select the proper value corresponding to the probe This setting will be valid all the time before it is changed again JN Caution The default attenuation coefficient of the probe on the instrument is preset to 10X Make sure that the set value of the attenuation switch in the probe is
33. ave Menu The description of the Save Function Menu is shown as the following table Setting Wave Setting Image Record When the type is Wave the menu shows as following CH1 Source CH2 Choose the waveform to be saved Math Choose the address which the waveform is Object I 15 saved to or recall from Recall or close the waveform stored in the current object address When the show is Object amp Show ON if the current object address has been Show ON used the stored waveform will be shown OFF the address number and relevant information will be displayed at the top left of the screen if the address is empty it will prompt None is saved Choose the saving type about the Record type see How to Record Playback Waveforms on P47 Type Save the waveform of the source to the selected address Whatever the Type of save menu is set you can save the Save l l waveform by just pressing the Copy panel button in any user interface Storage format is BIN Save to internal storage or USB storage If ET choose the USB storage the file name is Storage editable The waveform file could be open External waveform analysis software on the supplied CD When the type is Setting the menu shows as following 44 www tmatlantic com 5 Advanced User Guidebook Setting 1 Setting The setting address Settings eae Save the current oscilloscope setting to the v internal storage Load Recall the setting
34. aveform is inverted as it is shown in Fig 5 5 3 Press the H2 menu selection button again and select OFF for Inverted item 22 www tmatlantic com 5 Advanced User Guidebook The waveform goes back to its original one as it is shown in Fig 5 4 nan O o n o o o o n O O E G lll ee n a a Cell O N S Sitov _0 00a 12 5MS s M 500us PRE eas Coupling Inverted Prohe DC x10 Fig 5 4 Original Waveform 0 000ns ERER ee ee ee ae ee a e MA eoo saiv 12 5MS7 s M 500us A Coupling Inverted OOO DC ON OFF Probe x10 Fig 5 5 Inverted Waveform oO Use Mathematical Manipulation Function The Mathematical Manipulation function is used to show the results of the addition multiplication division and subtraction operations between Channel 1 and Channel 2 and the FFT operation of Channel 1 or Channel 2 23 5 Advanced User Guidebook Fig 5 6 Wave math menu The corresponding FCL Functional Capabilities List of the Waveform Calculation Function Menu __ _ Setting Fato CHR Select the signal source of the factor Dual Wf ae sien 87 Select the sign of mathematical manipulation Se Select the signal source of the factor2 Select CH1 as FFT source Source Select CH2 as FFT source Rectangle Blackman Window Select window for FFT Hanning Hamming Select dB for Format Format Select Vrms for Format Set multiple X 1 Set multiple X2 Zoom Set multiple X5 Set
35. ay function Turn off the XY display function Turn on the cymometer Cymometer Turn off the cymometer VGA Disp VGA Connect the VGA port to a monitor If set it as ON the waveform could be displayed on the port is optional computer monitor 40 www tmatlantic com 5 Advanced User Guidebook Display Type With the F1 menu selection button pushed down you can shift between Vect and Dots types The differences between the two display types can be observed through the comparison between Fig 5 30 and Fig 5 31 Tema Vom Tet Fee Sheet N Vinal Soe feed T e O A a leet Sat Tiel E tao EE feat Wool ott Jeet Wael fied omer Voce Jer A Vist Hast eh net Vet es Yee Veo Fecal Voc aaa S En ome Tea An aa We Jenny eon Gale mm Jamel Jeet emt feet Jeet Waal ona Quer a Yuu Dery Jiao Vem a Wein Ii 12 5M5 s M 500us Depth 100K _f 152v Persist XY Mode Cymometer VGA Disp OHE OO F F SOR O F F O F F Fig 5 30 Display in the Vector Form I rl Patt EA Weal Yani Neat Vane O E um tent Cer fet S flour Gar Wom mt ASE A fee E Pug S fam O fume Te E fat A A Come tn RI E he O A Hoot inet A a ume Lait E S TOE A aa T eT T Qe Teme tamed Wl A ft GY fos Celt O Toe Guy E Toe Yom Tae N Via Comat M S500us Type a S Ss j CS ib 5 2Vv Persist XY Mode Cymometerf VGA Disp Dots Weet OFF ON OFFI ON oFFf ONM OFF Fig 5 31 Display in Dots form Persist When the Persist function is used the persis
36. ced User Guidebook 1 Press the Display button and call out the Display Set Menu 2 Press the H3 menu selection button to set XY Mode ON The display format is changed to be XY mode see Fig 5 33 SOKS s M 1 0Oms Depth 1K Fig 5 33 XY Display Mode Cymometer It is a 6 digit cymometer The cymometer can measure frequencies from 2Hz to the full bandwidth Only if the measured channel has triggering signal and in Edge mode it can measure frequency correctly In the Single trigger mode it is a one channel cymometer and it can only measure the frequency of the triggering channel In the ALT trigger mode it 1s a two channel cymometer and it can measure the frequency of two channels The cymometer 1s displayed at the right bottom of the screen To turn the cymometer on or off 1 Press the Display button 2 In the Display menu press the H4 button to toggle between the cymometer display ON or OFF VGA Output VGA port is optional The VGA port could be connected to a computer monitor The image of the oscilloscope can be clearly displayed on the monitor To set the VGA Output l Press the Display button 2 Inthe Display menu press the H5 button to toggle between ON or OFF 43 www tmatlantic com 5 Advanced User Guidebook How to Save and Recall a Waveform Press the Save button you can save the waveforms settings or screen images The menu displayed in the screen is shown as Fig 5 34 Fig 5 34 Waveform S
37. comparing will stop and when it goes on running the number of Pass Fail will increase from the former number not from zero 5 When the waveform playback mode is on Pass Fail is used to test the played back waveform specially e Output Press the Utility button and turn the G to select the Output to go to the following menu Fig 5 45 Output menu The description of Output menu is shown as the follows Function Settin Description Menu ms a Type Trig level Output trig signal synchronously YP Pass fail Output High Level when Pass and Low Level when Fail e LAN Set 54 www tmatlantic com 5 Advanced User Guidebook Using the LAN port the oscilloscope can be connected with a computer directly or through the router to connect The network parameters can be set in the menu below Press the Utility button and turn the G knob to select the LAN Set to go to the following menu Fig 5 46 LAN Set menu The description of LAN Set menu is shown as the follows Function P ELA Press F1 button to switch between each byte turn the G knob to change value 0 255 Port Turn the G knob to change value 0 4000 Press F3 button to switch between each byte turn the G knob Netgate to change value 0 255 Press F4 button to switch between each byte turn the G knob Phy addr to change value O FF Press F5 button to switch between each byte turn the G knob Net mask to change value 0 255 Save the curr
38. d line cursors measurements The waveform of CH2 10 www tmatlantic com 13 14 15 16 17 18 19 20 21 22 Zo 4 Junior User Guidebook The frequency of the trigger signal of CH1 It indicates the current function menu Current trigger type T Rising edge triggering L Falling edge triggering ae Video line synchronous triggering wl Video field synchronous triggering The reading shows the trigger level value of the corresponding channel The reading shows the window time base value The reading shows the setting of main time base The readings show current sample rate and the record length It indicates the measured type and value of the corresponding channel F means frequency T means cycle V means the average value Vp the peak peak value Vk the root mean square value Ma the maximum amplitude value Mi the minimum amplitude value Vt the Voltage value of the waveform s flat top value Vb the Voltage value of the waveform s flat base Va the amplitude value Os the overshoot value Ps the Preshoot value RT the rise time value FT the fall time value PW the width value NW the Width value D the Duty value D the Duty value PD the Delay A B value and ND the Delay A Bt value The readings indicate the corresponding Voltage Division and the Zero Point positions of the channels The icon shows the coupling mode of the channel indicates direct
39. e waveform takes to rise from 10 to 90 of its amplitude Fall Time Time that the falling edge of the first pulse in the waveform takes to fall from 90 to 10 of its amplitude Width The width of the first positive pulse in 50 amplitude points Width The width of the first negative pulse in the 50 amplitude points Delay 1 2 The delay between the two channels at the rising edge Delay 1 2 The delay between the two channels at the falling edge Duty Duty Cycle defined as Width Period Duty Duty Cycle defined as Width Period How to Measure with Cursors Press the Cursor button to display the cursor measurement function menu CURS MEAS in the screen The Cursor Measurement for normal mode The cursor measurement includes Voltage Measurement and Time Measurement at normal mode shown as Fig 5 57 Fig 5 57 CURS MEAS Menu The description of the cursor measurement menu is shown as the following table 63 www tmatlantic com 5 Advanced User Guidebook pacity Switch off the cursor measurement vos Display the voltage measurement cursor and menu Time Display the time measurement cursor and menu Source CH1 Display the channel generating the waveform to CH2 which the cursor measurement will be applied When carrying out the cursor measurement the position of Cursor 1 can be adjusted with the VERTICAL POSITION knob of Channel 1 and that of Cursor 2 can be adjusted with the VERTICAL POSITION k
40. ency suppress and the low frequency suppress to smooth the high frequency or low frequency noise triggered by the interference 5 No Display Responses to the Push down of Run Stop Check whether Normal or Signal is chosen for Polarity in the TRIG MODE menu and the trigger level exceeds the waveform range If it is make the trigger level 1s centered in the screen or set the trigger mode as Auto In addition with the Autoset button pressed the setting above can be completed automatically 6 The displaying of waveform seems getting slow after increasing AVERAGE value in Acqu Mode see How to Implement Sampling Setup on P38 or a longer duration is set in the Persist in Display see Persist on P41 It s normal as the Oscilloscope is working hard on many more data points 80 www tmatlantic com 8 Technical Specifications 8 Technical Specifications Unless otherwise specified the technical specifications applied are for ADS 2031 2031V only and Probes attenuation set as 10X Only if the oscilloscope fulfills the following two conditions at first these specification standards can be reached E This instrument should run for at least 30 minutes continuously under the specified operating temperature E If change of the operating temperature is up to or exceeds 5C do Self calibration procedure see How to Implement Self calibration on P15 All specification standards can be fulfilled except one s marked with the word
41. ent settings and prompt reset to update the config How to connect with a computer directly 1 Connection Plug in the LAN line to the LAN port in the right side panel of the oscilloscope plug the other end into the interface of the computer 2 Set the network parameters of the computer Since the oscilloscope can not support obtaining an IP address automatically you should assign a static IP address Here we set the IP address to 192 168 1 71 55 www tmatlantic com 5 Advanced User Guidebook Internet Protocol TCP IP Properties General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate F settings Obtain an IF address automatically IP address Subnet mask Default gateway Obtain DNS server adi Use the following ONS server addresses Prefered DNS server H TBE Se Fig 5 47 Set the network parameters of the computer 3 Set the network parameters of the Oscilloscope Software Run the software on the computer choose the Ports settings of the Communications menu item Set Connect using to LAN About the IP the first three bytes is same as the IP in the step 2 the last byte should be different Here we set it to 192 168 1 72 The range of the port value is 0 4000 but the port which under 2000 is always be used so it 1s suggested to set it to the value above 2000 Here we set it to
42. enu attenuation coefficient as 10X and that of the switch in the probe switch as 10X see How to Set the Probe Attenuation Coefficient on P14 2 Connect the probe of Channel 1 to the measured point of the circuit 3 Press the Autoset button The oscilloscope will implement the Autoset to make the waveform optimized based on which you can further regulate the vertical and horizontal divisions till the waveform meets your requirement 2 Perform Automatic Measurement The oscilloscope can measure most of the displayed signals automatically To measure the period and frequency of the Channel and the mean and peak to peak voltage of the Channel 2 follow below steps 1 Press the Measure button to activate the measurement function menu 2 Press the H1 to display the Add menu 3 Press the F2 button to choose CH1 as the source 4 Press the F1 button the type items will display at the left of screen and turn the G knob to choose Period 5 Press the F4 button the period measurement will be added 6 Press the F1 button again the type items will display at the left of screen and turn the G knob to choose Freq 7 Press the F4 button the frequency measurement will be added finish settings of channel 1 8 Press the F2 button to choose CH2 as the source 9 Press the F1 button the type items will display at the left of screen and turn the G knob to choose Mean 10 Press the F4 button the mean measurement w
43. er input jack is blew the cover can be pried open with a straight screwdriver Restart the instrument after completing the checks above 2 After acquiring the signal the waveform of the signal is not displayed in the screen Check whether the probe is properly connected to the signal connecting wire Check whether the signal connecting wire is correctly connected to the BNC namely the channel connector Check whether the probe is properly connected with the object to be measured Check whether there is any signal generated from the object to be measured the trouble can be shot by the connection of the channel from which there is a signal generated with the channel in fault Make the signal acquisition operation again 3 The measured voltage amplitude value is 10 times or 1 10 of the actual value Look at the attenuation coefficient for the input channel and the attenuation ration of the probe to make sure they are match see How to Set the Probe Attenuation Coefficient on P14 4 There is a waveform displayed but it is not stable Check whether the Source item in the TRIG MODE menu is in conformity with the signal channel used in the practical application Check on the trigger Type item The common signal chooses the Edge trigger mode for Type and the video signal the Video Only if a proper trigger mode is applied the waveform can be displayed steadily Try to change the trigger coupling into the high frequ
44. ershoot and Preshoot Fig 5 55 below shows a pulse with some of the voltage measurement points 61 www tmatlantic com 5 Advanced User Guidebook Overshoot Vmax l N A Vtop y pE Vamp Vhase Vmin Freshoot Fig 5 55 Vpp Peak to Peak Voltage Vmax The maximum amplitude The most positive peak voltage measured over the entire waveform Vmin The minimum amplitude The most negative peak voltage measured over the entire waveform Vamp Voltage between Vtop and Vbase of a waveform Vtop Voltage of the waveform s flat top useful for square pulse waveforms Vbase Voltage of the waveform s flat base useful for square pulse waveforms Overshoot Defined as Vmax Vtop Vamp useful for square and pulse waveforms Preshoot Defined as Vmin Vbase Vamp useful for square and pulse waveforms Average The arithmetic mean over the entire waveform Vrms The true Root Mean Square voltage over the entire waveform The automatic measurement of time parameters The ADS 2031 2031V oscilloscopes provide time parameters auto measurements include Frequency Period Rise Time Fall Time Width Width Delay 124 Delay 1 2 Duty and Duty Figure 5 56 shows a pulse with some of the time measurement points 62 www tmatlantic com 5 Advanced User Guidebook Rise Time Fall Time oO l l l l l l i Width i AAA i Fig 5 56 Rise Time Time that the leading edge of the first pulse in th
45. f the waveform is turned on and its menu is displayed e If the waveform is on and its menu is not displayed its menu will be displayed e If the waveform is on and its menu is displayed the waveform is turned off and its menu goes away CH1 menu CH2 menu Couple setting Probe setting Fig 5 1 Channel Setting Menu 20 www tmatlantic com 5 Advanced User Guidebook The description of the Channel Menu is shown as the following list Setting DC Pass both AC and DC components of the input signal Coupling AC Block the DC component of the input signal GROUND Disconnect the input signal OFF Display original waveform Inverted ON Display inverted waveform X1 Match this to the probe attenuation factor to have an accurate reading of vertical scale 1 To set channel coupling Taking the Channel 1 for example the measured signal is a square wave signal containing the direct current bias The operation steps are shown as below 1 Press the CH1 MENU button and call out the CH1 SETUP menu 2 Press the H1 button the Coupling menu will display at the screen 3 Press the F1 button to select the Coupling item as DC Both DC and AC components of the signal are passed 4 Then press F2 button to select the Coupling item as AC The direct current component of the signal is blocked The waveforms are shown as Fig 5 2 Depth 100K Fig 5 2 AC Coupling Oscillogram 2 To adjust the probe attenuation
46. from the selected address When the type is Image the menu shows as following Save the current display screen The file can be only stored in a USB storage so a USB storage must be connected first The file name is editable The file is stored in BMP format Save and Recall the Waveform The ADS 2031 2031V oscilloscope can store 15 waveforms which can be displayed with the current waveform at the same time The stored waveform called out can not be adjusted In order to save the waveform of the CH1 into the address 1 the operation steps should be followed 1 Saving Press the H1 button the Type menu will display at the left of screen turn the G knob to choose Wave for Type 2 Press the H2 button and press F1 button to select CH1 for Source 3 Press the H3 button and press the F1 turn the G knob to select 1 as object address 4 Press the H5 button and press F1 button to select Internal 5 Press the H4 button to save the waveform 6 Recalling Press the H3 button and press the F1 turn the G knob to select 1 as object address Press F2 button to set Show as ON The waveform stored in the address will be shown the address number and relevant information will be displayed at the top left of the screen 45 www tmatlantic com 5 Advanced User Guidebook 12 5M5 s M 500us _f 40 0v Depth 100K Internal Fig 5 35 Wave Saving Tip Whatever the Type of save menu is set you can save the waveform by just
47. g conductor must be grounded The product must be grounded properly before any connection with its input or output terminal When powered by AC power it is not allowed to measure AC power source directly because the testing ground and power cord ground conductor are connected together otherwise it will cause short circuit To avoid electric shock there must be a ground wire connect between ground and the ground port on the back of product panel Check all Terminal Ratings To avoid fire or shock hazard check all ratings and markers of this product Refer to the user s manual for more information about ratings before connecting to the instrument Do not operate without covers Do not operate the instrument with covers or panels removed Use Proper Fuse Use only the specified type and rating fuse for this instrument Avoid exposed circuit Do not touch exposed junctions and components when the instrument 1s powered Do not operate if in any doubt If you suspect damage occurs to the instrument have it inspected by qualified service personnel before further operations Use your Oscilloscope in a well ventilated area Make sure the instrument installed with proper ventilation refer to the user manual for more details Do not operate in wet conditions Do not operate in an explosive atmosphere Keep product surfaces clean and dry l www tmatlantic com 2 Safety Terms and Symbols 2 Safety Terms and Symbols Safety Term
48. he horizontal direction of the screen indicating Cursorl and Cursor2 3 According to the measured waveform adjust the positions of Cursorl and Cursor2 by turning the VERTICAL POSITION knob of CH1 and CH2 Cursor increment window at the left bottom shows absolute value of the two cursors amplitude difference and the present position 66 www tmatlantic com 5 Advanced User Guidebook 0 000Hz 1 00001KHz SKS s 250Hz 800mv 0 00div Vamp Ma thFFT Fig 5 61 wave of Vamp cursor measurement Carry out the following operation steps for the Freq cursor measurement l 2A Press Cursor and recall the Cursor Measure menu Press the H1 button the Type menu will display at the right of the screen Press the F3 button to select Freq for Type with two purple dotted lines displayed along the vertical direction of the screen indicating the corresponding Cursor 1 and Cursor 2 According to the measured waveform adjust the positions of Cursorl and Cursor2 by turning the VERTICAL POSITION knob of CH1 and CH2 Increment window shows two cursors difference value and the present position See Fig 5 62 67 www tmatlantic com 5 Advanced User Guidebook 0 000Hz 4x 1 000KH2Z x1 5 000H2Z x2 1 005KHZ i 1 00001KHz SKS s 2S50Hz _f 800mv 0 00div Fig 5 62 wave of Freq cursor measurement How to Use Autoscale This is a very useful function for first time users to carry out a simple and quick test on the inp
49. he incoming signal and display the best possible viewing waveform of the signal and also works out some measurements for user as well The details of functions applied to the signal when using Autoset are shown as the following table 70 www tmatlantic com 5 Advanced User Guidebook Run Stop Enable or disable sampling on input signals Notice When there is no sampling at STOP state the vertical division and the horizontal time base of the waveform still can be adjusted within a certain range in other words the signal can be expanded in the horizontal or vertical direction When the horizontal time base is lt S50ms the horizontal time base can be expanded for 4 divisions downwards Single Press this button you can set the trigger mode as single directly so when trigger occurs acquire one waveform then stop Copy You can save the waveform by just pressing the Copy panel button in any user interface The source wave and the storage location are according to the settings of the Save function menu when the Type is Wave For more details please see Save Function Menu on P44 Jl www tmatlantic com 6 Demonstration 6 Demonstration Example 1 Measurement a Simple Signal The purpose of this example is to display an unknown signal in the circuit and measure the frequency and peak to peak voltage of the signal 1 Carry out the following operation steps for the rapid display of this signal 1 Set the probe m
50. ill be added 11 Press the F1 button the type items will display at the left of screen and turn the G knob to choose PK PK 12 Press the F4 button the peak to peak voltage measurement will be added finish 12 www tmatlantic com 6 Demonstration settings of channel 2 Then the period frequency mean and peak to peak voltage will be displayed at the bottom left of the screen and change periodically see Fig 6 1 0 000ns 1 25M857s M 400us 0 00m Depth 10K Fig 6 1 Measure Frequency and PK PK value for a given signal Example 2 Gain of a Amplifier in a Metering Circuit The purpose of this example is to work out the Gain of an Amplifier in a Metering Circuit First we use Oscilloscope to measure the amplitude of input signal and output signal from the circuit then to work out the Gain by using given formulas Set the probe menu attenuation coefficient as 10X and that of the switch in the probe as 10X see How to Set the Probe Attenuation Coefficient on P14 Connect the oscilloscope CH1 channel with the circuit signal input end and the CH2 channel to the output end Operation Steps 1 Press the Autoset button and the oscilloscope will automatically adjust the waveforms of the two channels into the proper display state 2 Press the Measure button to show the Measure menu 3 Press the H1 button 4 Press the F2 button and choose CH1 5 Press the F1 button and turn the G knob to choose PK PK 6
51. ipse is in the II and IV quadrants the determined phase difference angle is in the I and II quadrants that is within the range of 1 2 x or a 3m 2 78 www tmatlantic com 6 Demonstration Example 6 Video Signal Trigger Observe the video circuit of a television apply the video trigger and obtain the stable video output signal display Video Field Trigger For the trigger in the video field carry out operations according to the following Steps 1 Press the Trigger Menu button to display the trigger menu 2 Press the H1 button to display the trigger type menu 3 Turn the G knob to choose Video as the mode 4 Press the H2 button to display the Source menu 5 Press the F1 button to choose CH1 for Source 6 Press the H3 button to display the Modu menu 7 Press the F1 button to choose NTSC for the modulation 8 Press the H4 button to display the sync menu 9 Press the F2 button to choose Field for Sync 10 Turn the VOLTS DIV VERTICAL POSITION and SEC DIV knobs to obtain a proper waveform display see Fig 6 7 0 000ns A E Oy Oe CO ae a a OO ee ee EE rer See E OE e a A A R a O TEN D 125M57s M 50us Depth 100K Fig 6 7 Waveform Captured from Video Field Trigger 79 www tmatlantic com 7 Troubleshooting 7 Troubleshooting 1 Oscilloscope is powered on but no Display Check whether the power connection is connected properly Check whether the fuse which is beside the AC pow
52. ld Sync Odd Synchronic trigger in video odd filed Even Synchronic trigger in video even field Line NO Synchronic trigger in designed video line turn the G knob to set the line number Auto Acquire waveform even no trigger occurred Holdoff 100ns 10s adjust the G knob to set time interval before another trigger occur neon Reset Set Holdoff time as 100ns 3 Slope Trigger Slope trigger sets the oscilloscope as the positive negative slope trigger within the specified time The Slope Trigger Menu is shown as Fig 5 19 Fig 5 19 Slope trigger menu Slope trigger menu list Single Mode Source CHI Select CH1 as the trigger source CH Select CH2 as the trigger source Slope Set vertical channel trigger type as slope trigger 2 eo Slope selecting When Pe wr HE Set slope condition turn the G knob to set slope time ae le Threshold High level Adjust G knob to set the High level upper limit amp SlewRate Low level Adjust G knob to set Low level lower limit 35 www tmatlantic com 5 Advanced User Guidebook Slewrate Slew rate High level Low level Settings Auto Acquire waveform even no trigger occurred Normal Acquire waveform when trigger occurred Mode l Single When trigger occurs acquire one waveform then stop Holdoff 100ns 10s turn the G knob to set time interval before another trigger occur Reset Set Holdoff time as 100ns 4 Pulse Width Trigger Holdoff Pulse trigger occurs accordi
53. ld have an initial knowledge of the determination of the change of the oscilloscope setting through observing the status bar If you have not been familiar with the above mentioned operations and methods yet we advise you to read the section of Chapter 4 Junior User Guidebook This chapter will deal with the following topics mainly How to Set the Vertical System How to Set the Horizontal System How to Set the Trigger System How to Implement the Sampling Setup How to Set the Display System How to Save and Recall Waveform How to Record Playback Waveforms How to Implement the Auxiliary System Function Setting How to Implement the Automatic Measurement How to Implement the Cursor Measurement How to Use Autoscale function How to Use Executive Buttons It is recommended that you read this chapter carefully to get acquainted the various measurement functions and other operation methods of the ADS 2031 2031V oscilloscope 19 www tmatlantic com 5 Advanced User Guidebook How to Set the Vertical System The VERTICAL CONTROLS includes three menu buttons such as CH1 MENU CH2 MENU and Math and four knobs such as VERTICAL POSITION VOLTS DIV for each channel Setting of CH1 and CH2 Each channel has an independent vertical menu and each item is set respectively based on the channel To turn waveforms on or off channel math Pressing the CH1 MENU CH2 MENU and Math buttons have the following effect e If the waveform is of
54. liar with the use of the ADS 2031 2031V_ oscilloscope in the shortest time Front Panel The ADS 203 1 2031V oscilloscope offers a simple front panel with distinct functions to users for their completing some basic operations in which the knobs and function pushbuttons are included The knobs have the functions similar to other oscilloscopes The 5 buttons Fl F5 in the column on the right side of the display screen or in the row under the display screen H1 H5 are menu selection buttons through which you can set the different options for the current menu The other pushbuttons are function buttons through which you can enter different function menus or obtain a specific function application directly 1 2 3 Fig 4 1 Front panel Power on off Display area Control key and knob area Probe Compensation Measurement signal 5V 1KHz output EXT Trigger Input Signal Input Channel Menu off oA Se YS 6 www tmatlantic com 4 Junior User Guidebook Right Side Panel Fig 4 2 Right side panel 1 USB Host port It is used to transfer data when external USB equipment connects to the oscilloscope regarded as host device For example use this port to save waveform file into USB flash disk 2 USB Device port It is used to transfer data when external USB equipment connects to the oscilloscope regarded as slave device For example to use this port when connect PC to the oscilloscope by USB 3 COM VGA port Optio
55. nal To connect the oscilloscope with external equipment as serial port or to connect the oscilloscope with a monitor or a projector as VGA output 4 The port of trigger signal output amp Pass Fail output 5 LAN port the network port which can be used to connect with PC 7 www tmatlantic com 4 Junior User Guidebook Rear Panel a Se Fe C Ge EF DAMEN LILLIPUT TECHNOLOGY OO LTO ae FUJIAN HLUFUT OPTOELECTRONICS TECHNOLOGY CO LPO AWARNING ee SSS ee pu es m m n a LLLE POWE MAR pavi TERIAL HUMBER Fig 4 3 Rear Panel Handle Air vents AC power input jack Fuse Foot stool which can adjust the tilt angle of the oscilloscope 8 www tmatlantic com 4 Junior User Guidebook Control key and knob Area a ee Ea 1 Zo 6 7 8 Fig 4 4 Keys Overview Menu option setting H1 H5 Menu option setting F1 F5 Menu off turn off the menu G knob General knob when a O symbol appears in the menu it indicates you can turn the G knob to select the menu or set the value You can press it to close the menu on the left Function key area Total 12 keys Vertical control area with 3 keys and 4 knobs CH1 MENU and CH2 MENU correspond to setting menu in CH1 and CH2 Math key refer to math menu the math menu consists of six kinds of operations including CH1 CH2 CH2 CH1 CH1 CH2 CH1 CH2 CH1 CH2 and FFT Two VERTICAL POSITION knob control the vertical position of CH1 CH2 and two
56. ng to the width of pulse The abnormal signals can be detected through setting up the pulse width condition The Pulse Width Trigger Menu is shown as Fig 5 20 Fig 5 20 Pulse Width Trigger menu Pulse Width Trigger menu list MENU SETTING INSTRUCTION Set vertical channel trigger type as pulse trigger Single Mode Pulse Select CH1 as the trigger source Select CH2 as the trigger source S CH1 ource CH AC DC HF Coupling LF Polarity when Auto Mode Poa Single Holdoff nee Not allow DC portion to pass Allow all portion pass Not allow high frequency of signal pass and only low frequency portion pass Not allow low frequency of signal pass and only high frequency portion pass Choose the polarity Select pulse width condition and adjust the G knob to set time Acquire waveform even no trigger occurred Acquire waveform when trigger occurred When trigger occurs acquire one waveform then stop 100ns 10s adjust G knob to set time interval before another trigger occur Set Holdoff time as 100ns 36 www tmatlantic com 5 Advanced User Guidebook Term interpretation 1 Source Trigger can occur from several sources Input channels CH1 CH2 Ext Ext 5 Input It is the most commonly used trigger source The channel will work when selected as a trigger source whatever displayed or not Ext Trig The instrument can be triggered from a third source while acquiring data from CH1 and CH2
57. nob of Channel 2 Perform the following operation steps for the voltage cursor measurement of the channel CH1 1 Press Cursor and recall the Cursor Measure menu 2 Press the H2 button and choose CH1 for Source 3 Press the H1 button the Type menu will display at the right of the screen Then press the F2 button to choose Voltage for Type with two purple dotted lines displayed along the horizontal direction of the screen which indicating Cursor and Cursor2 4 According to the measured waveform adjust the positions of Cursorl and Cursor2 by turning the VERTICAL POSITION knob of CH1 and CH2 Cursor increment window at the left bottom of waveform shows absolute value of D value of cursor 1 and cursor 2 and the present position of the two cursors See Fig 5 58 0 000ns i 1 00000KHz ee NS eee 0 00m Depth 10K Fig 5 58 Waveform of Voltage Cursor Measurement Carry out the following operation steps for the time cursor measurement of the 64 www tmatlantic com 5 Advanced User Guidebook channel CH1 1 Press Cursor and recall the Cursor Measure menu 2 Press the H2 button and choose CH1 for Source 3 Press the H1 button the Type menu will display at the right of the screen Press the F3 button to select Time for Type with two purple dotted lines displayed along the vertical direction of the screen which indicating Cursor 1 and Cursor 2 4 According to the measured waveform adjust the positions of Curso
58. nob to choose Pass fail menu option Pass Fail menu will be displayed in the bottom 2 Enable switch on Press H2 button to show Operate menu then press F1 button to set Enable as ON 3 Create rule Press H4 button to enter Rule setting menu Press F1 button to choose the source Press F2 button turn the G knob to set Horizontal tolerance Press F3 button turn the G knob to set Vertical tolerance Press F4 button to create the rule 4 Set output type Press H3 button to enter Output option setting Choose any one or two of the options Pass Fail or Beep Pass and Fail are mutually exclusive options which could not be chosen simultaneously Stop means stop once the condition satisfies your setting 5 Begin to test Press H2 button then F2 button to select Start the test will begin 6 Save rule Press H5 button then F2 button to save the rules which could be called up at once when need press F3 button to call up the rule saved 53 www tmatlantic com 5 Advanced User Guidebook 1 300ms IRTA M 5 0ms _ 400mv Depth 100K pass fail Fig 5 44 Pass Fail test Note 1 When Pass Fail is ON if XY or FFT is ready to run then Pass Fail will be closed under the mode of XY or FFT Pass Fail is unable 2 Under the mode of Factory Auto Scale and Auto Set Pass Fail will be closed 3 When no save setting left in the rule save tip will be given to show NO RULE SAVED 4 Under the status of stop data
59. ntic com 8 Technical Specifications Trigger 6 div from the screen center Trigger level range 600mV Trigger level 40mV 6 of Set Value Accuracy typical EXT 5 200mV 6 of Set Value Tri i Wa According to Record length and time base displacement Trigger Holdoff 100ns 10s range 50 level setting Input signal frequency gt S50Hz typical Rising Falli E S ene _ ising alling Sensitivity Positive pulse gt lt Trigger condition Be negative pulse gt lt Pulse Width range 30ns 10s Support standard NTSC PAL and SECAM broadcast systems Video Trigger 1 525 NTSC and 1 625 PAL SECAM l n Positive pulse gt lt Trigger condition _ Slope Trigger negative pulse gt lt 24ns 10s Pulse trigger 83 www tmatlantic com 8 Technical Specifications General Technical Specifications Display Display Type 8 Colored LCD Liquid Crystal Display Display Resolution 800 Horizontal x 600 Vertical Pixels Display Colors 65536 colors TFT screen Output of the Probe Compensator Output Volt K ee About 5V with the Peak to Peak voltage 21MQ Typical Frequency Typical Square wave of 1KHz Power Mains Voltage 100 240 VAC RMS 50 60Hz CAT II 2A T grade 250V Environment Temperature Working temperature 0 C 40 C P Storage temperature 20 C 60 C Relative Humidity Height Operating 3 000 m Non operating 15 000 m Cooling Method
60. onnect the power cord to a power source Push down the button of the signal on the top The instrument carries out all self check items and shows the Boot Logo Press the Utility button then press H1 button to get access to the Function menu Turn the G knob to select Adjust and press H3 button to select Default The default attenuation coefficient set value of the probe in the menu is 10X 2 Set the Switch in the Oscilloscope Probe as 10X and Connect the Oscilloscope with CH1 Channel Align the slot in the probe with the plug in the CH1 connector BNC and then tighten the probe with rotating it to the right side 12 www tmatlantic com 4 Junior User Guidebook Connect the probe tip and the ground clamp to the connector of the probe compensator 3 Press the Autoset Button The square wave of 1 KHz frequency and 5V peak peak value will be displayed in several seconds see Fig 4 6 12 5MS s M S00us Depth 100K Edge Baal Fig 4 6 Auto set Check CH2 by repeating Step 2 and Step 3 How to Implement the Probe Compensation When connect the probe with any input channel for the first time make this adjustment to match the probe with the input channel The probe which is not compensated or presents a compensation deviation will result in the measuring error or mistake For adjusting the probe compensation please carry out the following Steps 1 Set the attenuation coefficient of the probe in the menu
61. out the signal The Average function offered by our Oscilloscope can help you to achieve this Here are the steps for how to enable Average function 1 Press the Acquire button to display the Acquire menu 76 www tmatlantic com 6 Demonstration 2 Press the H1 button to display ACQU Mode menu 3 Press the F3 button turn the G knob and observe the waveform obtained from averaging the waveforms of different average number User would see a much reduced random noise level and make it easy to see more details of the signal itself After applying Average user can easily identify the burrs on the rising and falling edges of some part of the signal see Fig 6 5 12 5MS s M 500us Depth 100K Fig 6 5 Reduce Noise level by using Average function Example 5 Application of X Y Function Examine the Phase Difference between Signals of two Channels Example Test the phase change of the signal after it passes through a circuit network X Y mode is a very useful when examining the Phase shift of two related signals This example takes you step by step to check out the phase change of the signal after it passes a specified circuit Input signal to the circuit and output signal from circuit are used as source signals For the examination of the input and output of the circuit in the form of X Y coordinate graph please operate according to the following steps 1 Set the probe menu attenuation coefficient for 10X and that of the s
62. pressing the Copy panel button in any user interface If the Storage of the save menu is set as External you should install the USB disk Please refer to the contents below to install the USB disk and name the file to be saved Save the current screen image The screen image can only be stored in USB disk so you should connect a USB disk with the instrument l Install the USB disk Insert the USB disk into the 1 USB Host port of Fig 4 3 Right side panel If an icon ES appears on the top right of the screen the USB disk is installed successfully The supported format of the USB disk FAT32 file system cluster size cannot exceed 4K Once the USB disk cannot be recognized you could format it into the supported format and try again After the USB disk is installed press the Save panel button the save menu is displayed at the bottom of the screen Press the H1 button the Type menu will display at the left of screen turn the G knob to choose Image for Type Press the H4 button the input keyboard used to edit the file name will pop up The default name is current system date Turn the G knob to choose the keys press the G knob to input the chosen key The length of file name is up to 25 characters Choose and press the Enter key of the keyboard to end the input and store the file with the current name 46 www tmatlantic com 5 Advanced User Guidebook 20111101_654523 character 4 _ aree i
63. rizontal ranges for the signal to be observed 3 Press the Acquire button to display the Acquire menu 4 Press the H1 button to display the Acquire Mode menu 5 Press the F2 button to choose Peak detect 74 www tmatlantic com 6 Demonstration 6 Press the Trigger Menu button to display the Trigger menu 7 Press the H1 button to display the Trigger Type menu 8 Turn the G knob to choose Edge as the mode 9 Press the H2 button to display the Source menu 10 Press the F1 button to choose CH1 as the source 11 Press the H3 button to display the Coupling menu press the F2 button to choose DC as the Coupling 12 Press the H4 button to choose ra rising as the Slope 13 Rotate the TRIG LEVEL knob and adjust the trigger level to the roughly 50 of the signal to be measured 14 Check the Trigger State Indicator on the top of the screen if it is not Ready push down the Run Stop button and start acquiring wait for trigger to happen If a signal reaches to the set trigger level one sampling will be made and then displayed in the screen By using this approach a random pulse can be captured easily For instance if we want to find a burst burr of high amplitude set the trigger level to a slightly higher value of the average signal level press the Run Stop button and wait a trigger Once there is a burr occurring the instrument will trigger automatically and record the waveform during the period around the trigger time By
64. rl and Cursor2 by turning the VERTICAL POSITION knob of CH1 and CH2 The cursor increment window at the left bottom of the waveform shows absolute difference frequency and the present time of the two cursors 0 000ns 4xi 1 000ms 1 4x 1 000KHZ x1 0 752ms x2 0 2468ms 1 00000KHz 1 25M57s M 400us f0 00m Depth 10K Fig 5 59 Waveform of Cursor Measurement The Cursor Measurement for FFT mode Press the Cursor button to display the cursor measurement function menu CURS MEAS in the screen which includes Vamp Measurement and Freq Measurement at the mode of FFT shown as Fig 5 60 65 www tmatlantic com 5 Advanced User Guidebook Fig 5 60 CURS MEAS Menu The description of the cursor measurement menu is shown as the following table Function Settin Description OFF Switch off the cursor measurement Type Vamp Display the Vamp measurement cursor and menu Freq Display the Freq measurement cursor and menu When carrying out the cursor measurement the position of Cursor 1 can be adjusted with the VERTICAL POSITION knob of Channel 1 and that of Cursor 2 can be adjusted with the VERTICAL POSITION knob of Channel 2 Perform the following operation steps for the Vamp cursor measurement 1 Press Cursor and recall the Cursor Measure menu 2 Press the H1 button the Type menu will display at the right of the screen Press the F2 button to select Vamp for Type with two purple dotted lines displayed along t
65. s Terms in this manual The following terms may appear in this manual LN Warning Warning indicates the conditions or practices that could result in injury or loss of life A Caution Caution indicates the conditions or practices that could result in damage to this product or other property Terms on the product The following terms may appear on this product Danger It indicates an injury or hazard may immediately happen Warning It indicates an injury or hazard may be accessible potentially Caution It indicates a potential damage to the instrument or other property might occur Safety Symbols Symbols on the product The following symbol may appear on the product Hazardous Voltage Refer to Manual Protective Earth Terminal rh Chassis Ground e Test Ground To avoid body damage and prevent product and connected equipment damage carefully read the following safety information before using the test tool This product can only be used in the specified applications A Warning The two channels of the oscilloscope are non isolated electrically The channels should adopt common basis during measuring To prevent short circuits the 2 probe ground must not be connected to 2 different non isolated DC level 2 www tmatlantic com 2 Safety Terms and Symbols A Warning The channels should adopt common basis during measuring To prevent short circuits the 2 probe ground must not be connected to 2 different non isolated
66. sitivity and anti clockwise to decrease 3 When the vertical position of the channel waveform is adjusted the changed value is displayed at the left bottom corner of the screen see Fig 5 12 0 000ns 1 25M57s M 400us _ 0 00m Depth 10K Fig 5 12 Information about Vertical Position 29 www tmatlantic com 5 Advanced User Guidebook How to Set the Horizontal System The HORIZONTAL CONTROLS includes the HORIZ MENU button and such knobs as HORIZONTAL POSITION and SEC DIV 1 HORIZONTAL POSITION knob this knob is used to adjust the horizontal positions of all channels include those obtained from the mathematical manipulation the analytic resolution of which changes with the time base 2 SEC DIV knob it is used to set the horizontal scale factor for setting the main time base or the window 3 HORIZ MENU button with this button pushed down the screen shows the operating menu see Fig 5 13 Fig 5 13 Time Base Mode Menu The description of the Horizontal Menu is as follows l Sey The setting of the horizontal main time base is Main Main Time B l used to display the waveform Set Set Window A window area is defined by two cursors This n function is not available at FFT mode Zoom Zoom Window The defined window area for display is expanded to the full screen Main Time Base Press the H1 menu selection button and choose Main In this case the HORIZONTAL POSITION and SEC DIV knobs are used to
67. t are significantly different Good for magnitude but poorer frequency resolution than Hamming Recommend to use for Hanning Sine periodic and narrow band random noise Transients or bursts where the signal levels before and after the event are significantly different 26 www tmatlantic com 5 Advanced User Guidebook Best solution for magnitude worst for frequency Recommend to use for Blackman Single frequency waveforms to find higher order harmonics Fig 5 8 5 9 5 10 5 11 are examples for measuring sine wave with a frequency of 1kHz under the selection of four different windows for FFT T oO 000Hz i I FFT j Source CH1 CH2 Window Rectangle mY a a Re AE a OAE P EO a aE S EE AAE A A Be O a T Format Vrms dB Zoom xX 1 1 00002KHz _f 800mv 0 O0div Dual Wfm FFT Math Fig 5 8 Rectangle window mo 000Hz Window Hamming 1 00001KHz _f 800mv 0 O0div Dual Wim FFT Math Fig 5 9 Hamming window Zt 5 Advanced User Guidebook 0 000Hz Window Hanning Format Vrms dB Zoom x1 1 00001KHz EZ EE 0 00div Dual Wfm Qe ____ PET Math Fig 5 10 Hanning window o FFT Source CH1 CH2 Window Blackman Zoom 1 00000KHz _f 800mv 0 O0div Dual Wim FFT Math Fig 5 11 Blackman window Notes for using FFT E Use Zoom function to magnify the FFT waveform if necessary E Use
68. tence display effect of the picture tube oscilloscope can be simulated The reserved original data is displayed in fade color and the new data is in bright color Press the H2 button the Persist menu will display at the right of screen Press the F1 button different persistence time can be chosen 4 5 Advanced User Guidebook OFF Isecond 2second 5second and Infinity When the Infinity option is set for Persist time the measuring points will be stored till the controlling value is changed see Fig 5 32 By pressing the F2 button the persistence will be cleared 160 0us 12 5MS s M 500us Depth 100K Fig 5 32 Infinite Persistence Display XY Format This format is only applicable to Channel 1 and Channel 2 After the XY display format is selected Channel 1 is displayed in the horizontal axis and Channel 2 in the vertical axis the oscilloscope is set in the un triggered sample mode the data are displayed as bright spots The operations of all control knobs are as follows E The Vertical VOLTS DIV and the VERTICAL POSITION knobs of Channel 1 are used to set the horizontal scale and position E The Vertical VOLTS DIV and the VERTICAL POSITION knobs of Channel 2 are used to set the vertical scale and position continuously The following functions can not work in the XY Format Reference or digital wave form Cursor Time base control Trigger control FFT Operation steps 42 www tmatlantic com 5 Advan
69. terssciavacesancsausnsaacsasnsiemsauisesatedeviasstenis 79 Te MPOUMDICSHOONNO osr A EEE E 80 Os LECH ICE Specifica ONS sssrin N EE l General Technical SOCCINCAOMS isesi eara S EN 84 T APPENUIN serinin rnn e EEE EE EEEE AANEEN EEEREN 85 Appendix A CLO EC ravi sss cca ccenecc esse cct usana aaas aas aaRS TE siias 85 Appendix B General Care and le amine vsissscscsaceiiesversccascensssasnstesdnusecutinsasaaavsaseteicneianiendeseiwuns 85 ll www tmatlantic com 1 General Safety Requirements 1 General Safety Requirements Before any operations please read the following safety precautions to avoid any possible bodily injury and prevent this product or any other products connected from damage In order to avoid any contingent danger this product is only used within the range specified Only the qualified technicians can implement the maintenance To avoid Fire or Personal Injury Connect the probe correctly The grounding end of the probe corresponds to the grounding phase Please don t connect the grounding end to the positive phase Use Proper Power Cord Use only the power cord supplied with the product and certified to use in your country Connect or Disconnect Correctly When the probe or test lead is connected to a voltage source please do not connect and disconnect the probe or test lead at random Product Grounded This instrument is grounded through the power cord grounding conductor To avoid electric shock the groundin
70. the default dB scale for details of multiple frequencies even if they have very different amplitudes Use the Vrms scale to compare frequencies E DC component or offset can cause incorrect magnitude values of FFT waveform To minimize the DC component choose AC Coupling on the source signal E To reduce random noise and aliased components in repetitive or single shot events set the oscilloscope acquisition mode to average 28 5 Advanced User Guidebook What is Nyquist frequency The Nyquist frequency is the highest frequency that any real time digitizing oscilloscope can acquire without aliasing This frequency is half of the sample rate Frequencies above the Nyquist frequency will be under sampled which causes aliasing So pay more attention to the relation between the frequency being sampled and measured Note In FFT mode the following settings are prohibited 1 Window set 2 XY Format in Display SET 3 Measure Use VERTICAL POSITION and VOLTS DIV Knobs 1 The VERTIVAL POSITION knob is used to adjust the vertical positions of the waveforms including the captured waveforms and calculated waveforms The analytic resolution of this control knob changes with the vertical division 2 The VOLTS DIV knob is used to regulate the vertical resolution of the wave forms including the captured waveforms and calculated waveforms The sensitivity of the vertical division steps as 1 2 5 Turning clockwise to increase vertical sen
71. the same as the menu selection of the probe attenuation coefficient in the oscilloscope The set values of the probe switch are 1X and 10X see Fig 4 9 14 www tmatlantic com 4 Junior User Guidebook Fig 4 9 Attenuation Switch JN Caution When the attenuation switch is set to 1X the probe will limit the bandwidth of the oscilloscope in SMHz To use the full bandwidth of the oscilloscope the switch must be set to 10X How to Use the Probe Safely The safety guard ring around the probe body protects your finger against any electric shock shown as Fig 4 10 Fig 4 10 Finger Guard Warning To avoid electric shock always keep your finger behind the safety guard ring of the probe during the operation To protect you from suffering from the electric shock do not touch any metal part of the probe tip when it is connected to the power supply Before making any measurements always connect the probe to the instrument and connect the ground terminal to the earth How to Implement Self calibration The self calibration application can make the oscilloscope reach the optimum condition rapidly to obtain the most accurate measurement value You can carry out this application program at any time This program must be executed whenever the change of ambient temperature is 5 C or over Before performing a self calibration disconnect all probes or wires from the input connector Press the Utility button then press H1 but
72. tical VOLTS DIV knob and change the Vertical Scale Factor Voltage Division it can be found that the scale factor of the channel corresponding to the status bar has been changed accordingly Press buttons of CH1 MENU CH2 MENU and Math the operation 16 www tmatlantic com 4 Junior User Guidebook menu symbols waveforms and scale factor status information of the corresponding channel will be displayed in the screen Introduction to the Horizontal System Shown as Fig 4 12 there are a button and two knobs in the HORIZONTAL CONTROLS The following practices will gradually direct you to be familiar with the setting of horizontal time base Fig 4 12 Horizontal Control Zone 1 Use the horizontal SEC DIV knob to change the horizontal time base setting and observe the consequent status information change Rotate the horizontal SEC DIV knob to change the horizontal time base and it can be found that the Horizontal Time Base display in the status bar changes accordingly 2 Use the HORIZONTAL POSITION knob to adjust the horizontal position of the signal in the waveform window The HORIZONTAL POSITION knob is used to control the triggering displacement of the signal or for other special applications If it is applied to triggering the displacement it can be observed that the waveform moves horizontally with the knob when you rotate the HORIZONTAL POSITION knob 3 With the HORIZ MENU button you can do the
73. to Implement Self calibration esosssseccocsssseccccssseccccssseccocsssecesessssseccsssssecesssssecessssseeese 15 Introduction to the Vertical Sy SteM ciccisscssssccccsenscsseaasssiesencesedccaavedsasceesbensensedioaiseavecsswacecnvetsasien 16 Introduction to the Horizontal System sssesesoocsssssseececcososssssececocososssssececesoosssssssesseososssssssee 17 Introduction to the Trigger System sssssssececccccsssssseseccocoscssseseceseocosssssseseceocossssssseceseesosssssseee 17 5 Advanced User GUNA CU OGG caneineserpaseatecentsausinesesacesun iensessieossenevsssesnausvactensvanssereseuieeue sess 19 How to Set the Vertical Systeni ireen a E EEEN S 20 Use Mathematical Mamipulation FONGO isc acease se ceceantee tas ements sae sues ase EEEa 23 Usma FET NCO seseina ai ii a a aidai iaa 25 Use VERTICAL POSITION and VOLTS DIV Kn0bS sssessececccscsssssscecccccosssssssececoosossssssee 29 How to Set the Horizontal System sccssssseseccccccssssssecceosoccssssseccccoocsssssseccccosossssssseesessssssssssee 30 How to Set the Triper Sy Sten ives csccscsciccsetcssnsncaverscaescusivsssenwassdacsessrcantaascevevesessesianesbetousbiocssians 33 How to Operate the Function Menu siess aeni aoa a aei ERE 38 How to Implement Sampling Setup s000cccccscceeeceseesssesssseececcceeeeneeenseesesssneensenececereesecenseessszens 38 How to Sethe Display VU aeneon erase oie wns ssn closivnccmta cate OODE EEANN aasia 40 How to Savo and
74. ton to call out the Function menu turn the G knob to choose Adjust Press H2 button to choose the option Self 15 www tmatlantic com 4 Junior User Guidebook Cal run the program after everything is ready Introduction to the Vertical System As shown in Fig 4 11 there are a few of buttons and knobs in VERTICAL CONTROLS The following practices will gradually direct you to be familiar with the using of the vertical setting Fig 4 11 Vertical Control Zone 1 Use the button VERTICAL POSITION knob to show the signal in the center of the waveform window The VERTICAL POSITION knob functions the regulating of the vertical display position of the signal Thus when the VERTICAL POSITION knob is rotated the pointer of the earth datum point of the channel is directed to move up and down following the waveform Measuring Skill If the channel is under the DC coupling mode you can rapidly measure the DC component of the signal through the observation of the difference between the wave form and the signal ground If the channel is under the AC mode the DC component would be filtered out This mode helps you display the AC component of the signal with a higher sensitivity 2 Change the Vertical Setting and Observe the Consequent State Information Change With the information displayed in the status bar at the bottom of the waveform window you can determine any changes in the channel vertical scale factor Turn the ver
75. ut signal The function 1s applied to follow up signals automatically even if the signals change at any time Autoscale enables the instrument to set up trigger mode voltage division and time scale automatically according to the type amplitude and frequency of the signals Fig 5 63 Autoscale menu The menu is as follows ON Turn on Autoscale Autoscale OFF Turn off Autoscale 68 www tmatlantic com 5 Advanced User Guidebook Follow up and adjust both vertical and horizontal settings Follow up and only adjust horizontal scale Follow up and only adjust vertical scale Show Multi period waveforms Only show one or two periods If you want to measure the two channel signal you can do as the follows 1 Press Autoscale button the function menu will appear 2 Press H1 to choose ON 3 Press H2 and choose ee for Mode item 4 Press H3 and choose ATATAT for Wave item Then the wave is displayed in the screen shown as Fig 5 64 0 000ns 1 25M5 s M 400us Depth 10K Cad Fig 5 64 Autoscale Horizontal Vertical multi period waveforms Note 1 Entering into Autoscale function and the symbol A will be flickering on the top left of the screen every 0 5 second 2 In the mode of Autoscale the oscilloscope can self estimate Trigger Mode Edge Video At this point the trigger menu is not available 3 At the mode of XY and STOP status pressing Autoset to enter into Autoscale DSO switches to
76. witch in the probe for 10X see How to Set the Probe Attenuation Coefficient on P14 2 Connect the probe of channel 1 to the input of the network and that of Channel 2 to the output of the network 3 Push down the Autoset button with the oscilloscope turning on the signals of the two channels and displaying them in the screen 71 www tmatlantic com 6 Demonstration 4 Turn the VOLTS DIV knob making the amplitudes of two signals equal in the rough 5 Press the Display button and recall the Display menu 6 Press the H3 button and choose XY Mode as ON The oscilloscope will display the input and terminal characteristics of the network in the Lissajous graph form 7 Turn the VOLTS DIV and VERTICAL POSITION knobs optimizing the waveform 8 With the elliptical oscillogram method adopted observe and calculate the phase difference see Fig 6 6 The signal must be centered and kept in the horizontal direction Fig 6 6 Lissajous Graph Based on the expression sin q A B or C D thereinto q is the phase difference angle and the definitions of A B C and D are shown as the graph above As a result the phase difference angle can be obtained namely q arcsin A B or arcsin C D If the principal axis of the ellipse is in the I and II quadrants the determined phase difference angel should be in the I and IV quadrants that 1s in the range of 0 n 2 or 3a 2 2n If the principal axis of the ell
77. y to quit 1MS s M 5 0ms _f0 00mv Depth 100K Fig 5 42 Self Calibration Pass Fail The Pass Fail function monitors changes of signals and output pass or fail signals by comparing the input signal that is within the pre defined mask Press the Utility button and turn the G knob to select the Pass fail to go to the following menu pass fail Fig 5 43 Pass Fail menu 52 www tmatlantic com 5 Advanced User Guidebook The description of Pass Fail Menu is shown as the follows Control enable switch Operate Control operate switch Signal tested corresponds with the rule Signal tested not correspond with the rule Output Beep when it satisfies the rule Stop once satisfying the rule Control the display status of info frame Source Select source CH1 CH2 or Math Horizontal Change the Horizontal tolerance value by turning the G knob Vertical Change the Vertical tolerance value by turning the G knob Create Use the rule set as testing rule Number Choose any one from Rulel Rule8 as your rule name SaveRule Save Click Save to save the rule Load Load some rule as the testing rule Pass Fail test Detect whether the input signal is within the limits of the rule if it exceeds limits of the rule it is Fail otherwise it is Pass Also it can output fail or pass signal by built in and configurable output port To run the test read the following steps l Press Utility button then H1 button turn the G k