Instruction of Using Veterinary SpO2 Probes

image

Contents

1. press the sensor into one of the fixing slots Fig 7 then fix the other sensor Fig 1 Fig 2 Fig 3 Big Clip Connection LY A hi Fig 6 Fig 7 Rubber Wrapper Connection Fig 4 Fig 5 Small Clip Connection Rubber jackets Clip and Sensor 900184 Instruction of Using Veterinary SpO Probes Placement of Veterinary SpO Probe As a general rule measuring SpO for animals is performed when the animal is under anaesthesia and the optimal measuring site is their tongues Normally the animal s tongue will slip out after anaesthesia At first clip the probe on its tongue Fig 8 Then according to perfusion index PI value greater PI is better you can find an appropriate site Besides the tongue you can clip or wrap the SpO sensor onto other places such as legs or tail Fig 9 Since animal hair will decrease the sensitivity or even make the measurement failure please always choose the place with less hair under the sensor If necessary shave off the hair on the measuring site Tips for SpO Monitoring If there is strong ambient light interference you can use opaque thing to cover the measuring site and the probe By doing so measurement distortion may be avoided The lights including surgery lamp halogen lamp fluorescent lamp and infrared heating lamp can also cause measurement distortion In such condition you can use solid black thing to cover the measuring site and the probe If PI v
2. Instruction of Using Veterinary SpO Probes Choosing Veterinary SpO Probe PC 66V Handheld Pulse Oximeter is equipped with special probes for monitoring animals Now two types of SpO probes with three kinds of adapters are provided one is the Y type probe with clear coating on the sensor which is suitable for big animals or where the tissue is thick or dark the other one is the Y type probe with opaque coating on the sensor which is suitable for small animals or where the tissue is thin or transparent The three kinds of probe adapters are big clip small clip and rubber wrapper respectively which can be used on different measuring site accordingly such as tongue ear leg or tail Please choose the appropriate probe and adapter according to its character and the measuring site Connection of Small Clip Follow the step 1 step 2 and step 4 mentioned in SpO Probe Connection Connection of Big Cli 1 Take off the two rubber jackets from the clip 2 Fix the sensor cable to the clip Fig 1 3 Slide one sensor the side with coating inward into the fixing slot from the clip opening to the stop at the end of the slot Fig 2 and then fix the other sensor 4 Install the two rubber jackets to the clip Fig 3 Section Connection of Big Clip and refer to Fig 4 and Fig 5 Connection of Rubber Wrapper l Spread the rubber wrapper there are two fixing slots Fig 6 Hold the rubber wrapper and
3. alue is less than 1 the probe with clear coating on the sensor is recommended for a better measurement result Amendment to PC 66B User Manual Dear Users The operation and software of PC 66V are almost the same as PC 66B but there are some differences so the corresponding information in PC 66B User Manual needs to be amended for your use Details read as follows 1 The following information will be added to Section 4 5 On the above mentioned screens longtime press 66 key for entering menu screen as shown below MENU UPLOAD DATA VERSION SETUP set parameter values Refer to Section 4 5 for detailed setup operations e UPLOAD DATA reserved for future use VERSION display version information Select the item SETUP UPLOAD DATA or VERSION with Navigation Key then press Er key for entering sub menu screen 2 Pulse Rate detecting range can be selected so the Figure 10 Menu Setup Screen C in section 4 5 is replaced with the following figure ALARM PR LO 50 PR RANGE 25 200 PULSE SOUND REC INTERVAL Fig 10 Setup Screen C PR RANGE choose the pulse rate range Two options 25 200 bpm or 120 410 bpm Operation Instruction Long time press A V Navigation key to shift cursor continuously or increase decrease numerical value continuous Short time press A V Navigation key to shift cursor or increase decrease numerical value single t
4. ime 3 The following operation instruction will be added to section 4 6 1 SpO 12 50 35 SpO Trend PR Trend Trend Recall Screen Operation Instruction On trend recall screen if PR scale values show on the screen but no PR trend it means the PR value exceeds the current PR display range There are two groups of PR scale range 25 200 or 120 410 Longtime press os key the current right scale values will be changed to the other group of PR scale values thus you can view PR trend of full range 30 400 4 Brief Comparison between PC 66V and PC 66B Handheld Pulse Oximeters Performance Differences between PC 66V and PC 66B PC 66V PC 66B SpO sensor photodetector Photodiode Light frequency converter Y type probes with clear and Opaque coating on 2 different sensors adapters of big small SpO probe type clips and rubber wrapper are provided PR measuring range 30 400bpm 30 240bpm f Low end 25 200bpm PR range selection Miek ead 024 Oyen Reusable adult and pediatric clip probes disposable neonatal Y type probes with wrapper Full range 30 240bpm Intended use for

Download Pdf Manuals

image

Related Search

Related Contents

Lincoln Electric 655/R Welder User Manual  VGN-CS Series  Flex Network 高速カウンタユニット取扱説明書  仕様書(PDF:123KB)  Panasonic Toughpad 4K User's Manual  ACCUEIL DE GROUPES SCOLAIRES - Le Valet de Coeur  Advanced User Manual  QVS AS-401S User's Manual  instrucciones_instalacion... - PS-POOL  Jabra Rox Wireless  

Copyright © All rights reserved.
Failed to retrieve file