Home

User Manual - CyberPower Systems

image

Contents

1. erPower he Power To Control the Power User Manual for CPS 00AVR and PowerPanel Plus Software User Manual ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT www cyberpowersystems com faqs htm CyberPower TABLE OF CONTENTS Determining Power Requirements 1 Hardware Installation Guide 2 Software Installation Guide 3 Software User Manual 4 WENT gncoidccccutaciwicasenpieaiseuriiens 10 Thank you for purchasing a CyberPower Systems Product To enjoy all the features and benefits of this Uninterruptible Power System UPS please read and follow all installation and operation instructions completely This UPS is designed to provide guaranteed power protection for connected electronic equipment The accompanying PowerPanel Plus software saves data closes open applications and automatically shuts down your computer system in an intelligent and orderly manner IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important safety instructions Please read and follow all instructions carefully during installation and operation of unit Read this manual thoroughly before attempting to unpack install or operate CAUTION To prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminants Please see specifications for acceptable temperature and humidity range CAUTION To red
2. 2 Enter some data into the application 3 Unplug the UPS from the AC outlet When a power failure occurs PowerPanel Plus will appear on the screen The outlet and battery symbols will change to indicate a power failure The countdown timer will move towards zero When the timer reaches zero the software will begin to save and close any open applications The software will auto assign names to any files that have not been previously saved and then save the file to the PCTemp folder which is located in the root directory of your C drive where C is the name of your main hard drive Once all open files have been saved and closed PowerPanel Plus will shut down the operating system Once the operating system is shutdown the UPS will turn off within 90 seconds Wait until the UPS has turned off before plugging the UPS back into the outlet Once the test has been completed plug the UPS back into the AC outlet and turn it back on You may then restart your computer Please allow 4 hours for the UPS to recharge before attempting another self test If you are not using PowerPanel Plus Have your computer and UPS turned on Unplug the UPS from the wall to simulate a power failure The UPS will begin beeping indicating a power failure Save and close any open files Shut down the operating system Once the computer system is shutdown turn the UPS off Poo CPS700AVR Guaranteed Uninterruptible Power System As the battery disch
3. battery Number of Batteries 12V 7 5AH x 1 Recharge Time 4 to 8 hours from total discharge Interface RS 232 with Plug and Play interface LED Indicators Power On Electrical Wiring Fault AVR Using Battery Check Batter Output Receptacles 2 Battery powered and full time surge protection 4 full time surge protection CPS700AVR Guaranteed Uninterruptible Power System EXPECTED RUNTIME IN MINUTES Example Systems Load Watts CPS 700AVR Model Runtime Desktop PC with 15 Monitor 38 45 Desktop PC with 17 Monitor 28 36 Desktop PC with 21 Monitor 24 28 Tower PC with 21 Monitor 20 24 REPLACING THE BATTERY CAUTION Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery Service the battery under the supervision of personnel knowledgeable of batteries and their precautions CAUTION Use only the specified type of battery See your dealer for replacement batteries CAUTION The battery may present risk of electrical shock Do not dispose of battery in a fire as it may explode Follow all local ordinances regarding proper disposal of batteries CAUTION Do not open or mutilate the batteries Released electrolyte is harmful to skin and eyes and may be toxic CAUTION A battery can present a high risk of short circuit current and electrical shock Take the following precautions before replacing the battery Remove all watches rings or other metal objects Only use tools
4. circuit breaker and does not service equipment with large electrical demands e g refrigerator copier etc Avoid using extension cords If used the extension cord must be rated for 15 amps Depress the power switch to turn the unit on The power on indicator light will illuminate If an overload is detected an audible alarm will sound and the unit will emit one long beep To correct this turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets Wait 10 seconds Make sure the circuit breaker is depressed and then turn the UPS on Your UPS is equipped with an auto charge feature When the UPS is plugged into an AC outlet the battery will automatically recharge To maintain optimal battery charge leave the UPS plugged into an AC outlet at all times To store your UPS for an extended period cover it and store with the battery fully charged Recharge the battery every three months to insure battery life CPS700AVR Guaranteed Uninterruptible Power System POWERPANEL PLUS SOFTWARE INSTALLATION GUIDE Note Use of the software is optional The UPS will provide surge suppression and battery backup without the software You must use the software if you wish to have the automatic shutdown feature FOR WINDOWS 95 98 Me Turn the UPS off and unplug it Connect the serial interface cable to the UPS and an open serial port on the back of the computer Note You must use the serial cable that was s
5. cord be used Use only shielded cables to connect I O devices to this equipment CAUTION Any changes or modifications not expressly approved by the guarantee of this device could void the user s authority to operate the equipment CyberPower The Power To Control the Power For more information contact us at CyberPower Systems USA Inc 5555 12 Avenue East Suite 110 Shakopee MN 55379 Tel 952 403 9500 Fax 952 403 9500 Email sales cyberpowersystems com Web www cyberpowersystems com Entire contents copyright 2001 CyberPower Systems Inc All rights reserved Reproduction in whole or in part without permission is prohibited PowerPanel is a trademark of CyberPower Systems USA Inc
6. of CyberPower as permitted by law pay to the Initial Customer the Agreed Damage Amount up to the aggregate limits stated below for all item s of Initial Customer s Connected Equipment The Agreed Damage Amount for all items of Initial Customer s Connected Equipment shall be the lesser of the amount determined under Clause 1 or 2 below reduced by any amounts described in Clause 3 below 1 The fair market value of the Connected Equipment as established by the lower of a the average price the same or similar items are being sold for on eBay b the price list of the Boston Computer Exchange on the date of occurrence or if such price list is no longer published a published or announced price list reasonably selected by CyberPower or c the lowest price the Connected Equipment can be purchased for in the United States or 2 The aggregate ceiling amount for all Connected Equipment as set forth below minus 3 The amount s of all payment you have or are entitled to receive from insurance other warranties extended warranties or from other sources or persons for the Connected Equipment or damage to such equipment so that CyberPower s maximum liability shall be reduced to reflect all such other payments or sources of recovery CyberPower CPS700AVR 175 000 4 If CyberPower replaces the Connected Equipment or pays to the Initial Customer the Agreed Damage Amount the Initial Customer shall transfer such item s to CyberPow
7. software Setup Button Click the setup button to open the Setup Window Model This shows the model of the CyberPower UPS that is being used Version This shows the hardware version Status Bar The area display messages about the status of the software Schedule Button Click this button to access the Schedule Window SaaS a S POWERPANEL PLUS MAIN WINDOW DESCRIPTION E 5 1 Input Voltage This reading shows the current input voltage of the utility power The input normally appears in green but will turn red if the input voltage is lower than 85v or higher than 150v Battery Level This indicator displays the current charge on the battery The indicator will display a red color when a power failure occurs Frequency This indicator displays the frequency of the utility power Scheduled On PowerPanel Plus can be scheduled to turn your computer system on It can only be set when a Scheduled Off is also set Scheduled On settings that are set to occur within seven days will be displayed When the UPS is in standby after the Scheduled Off the using battery and check battery indicators will flash in rotation 5 Final Countdown When PowerPanel Plus detects that the utility voltage is below 85 volts or above 150 volts the Final Countdown will begin When the countdown reaches zero PowerPanel Plus will save and close any open applications and then shut down the operating system in an intelligent and orderly manner 6 Approx
8. status to the PowerPanel Plus software This interface is also This LED indicator will illuminate to warn the user that a wiring problem compatible with the UPS service provided by Windows NT and exits with the AC outlet such as bad ground miss ground or reversed Windows 2000 wiring If this is illuminated the user is advised to disconnect all 7 Battery Power Supplied Outlets electrical equipment from the outlet and have an electrician check the Provides two battery supplied outlets with surge protection for outlet to insure proper wiring connected equipment and insures temporary uninterrupted operation of 3 Using Battery your equipment during a power failure This illuminates during utility failure indicating that the battery is 8 Re settable Circuit Breaker supplying power to the battery power supplied outlets The circuit breaker provides circuit overload and fault protection 4 Power Switch 9 Always on Surge Protection Outlets Can be used as a master on off switch for equipment connected to the Provides two full time surge protection outlets to provide surge battery power supplied outlets suppression for connected equipment 5 Communication Protection Ports Communication protection ports will protect any standard phone fax or modem line INSPECTION The box should contain the following 1 PowerPanel Plus software floppy disk 1 serial interface cable DB 9 1 telephone communication cable 1 user manual 1 warr
9. this Limited Warranty You may also contact CyberPower on the Internet at www cyberpowersystems com FCC Notice This equipment has been tested and found to comply with the limits for a Class B Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced radio TV technician for help Any special accessories needed for compliance must be specified in the instruction CAUTION A shielded type power cord is required in order to meet FCC emission limits and also to prevent interference to the nearby radio and television reception It is essential that only the supplied power
10. to Connected Equipment the Power Control Guarantee covers only damage within the specific terms of the Power Control Guarantee to Connected Equipment and only up to the applicable aggregate ceiling amount The Power Control Guarantee does not cover damage to Connected Equipment or apply if the product has been operated in a failure mode or not in compliance with CyberPower operating instructions and manuals Or if the Connected Equipment has been operated in a failure mode or not in compliance with the instruction and manuals of its manufacturer vendor The Limited Warranty and the Power Control Guarantee Do Not Apply Unless The Initial Customer 1 Has properly connected the Product and the Connected Equipment to properly wired and grounded outlets power supplies including compliance with electrical and safety codes of most current National Electrical Code ANSI NFPA 70 without the use of any adaptors extension cords or other connectors 2 Has provided a suitable and proper environment for use and installation of the Product and Connected Equipment 3 Has properly installed and operated the CyberPower Product and Connected Equipment CyberPower Does Not Cover or Undertake Any Liability in Any Event for Any of the Following h Loss of or damage to data records or software restoration of data or records or reinstallation of software 2 Damage from causes other than AC Power Line Transients spikes or surges on properly installed
11. 10 120v 60Hz outlet AC outlet The battery is worn out Contact CyberPower Systems about replacement batteries at tech cyberpowersystems com Mechanical problem Contact CyberPower Systems about at tech cyberpowersystems com PowerPanel Plus is inactive The serial cable is not Connect the serial cable to the UPS unit and an open serial port all icons are gray connected on the back of the computer You must use the cable that came with the unit The serial cable is connected to Check the back of the computer for an additional serial port the wrong port Move the cable to this port The unit is not providing battery Shutdown your computer and turn the UPS off Wait 10 seconds power and turn the UPS back on This should reset the unit The serial cable is not the cable You must use the cable that was included with the unit for the that was provided with the unit software and the unit to be able to communicate SPECIFICATIONS General CPS700AVR Capacity 700VA 350W Input 57Hz to 63Hz Voltage Range 85v 150v UPS Output Line Conditioning AVR Max boost 26 of input voltage for output Regulation regulation while input voltage is from 8 to 30 under nominal AVR buck 13 of input voltage for output regulation while input voltage is from 8 to 26 over nominal On Battery Output 120 Vac 5 user adjustable wave form Full time Surge Protection Output 12 Amps Battery Battery type Sealed Maintenance free lead acid
12. Exits the window Please note You must click Add to add the item to the schedule Turn Off Select the day date and time that you want the computer system to shutdown This is optional to use and has no effect on whether your computer will shut down during a power failure Weekly Setting Allow you to schedule a shutdown and start up based upon the day of the week ah e O ONO POWERPANEL PLUS LOG MENU 1 Event Option Button When this option is selected the log will display different PowerPanel Plus events such as power failure program start and program end 2 Log Display This area displays the information as selected by the Event Closed Application Information or Data Record option button 3 Clear Clears the selected log 4 Cancel Exits the screen without saving any changes 5 OK Exits the screen and saves any changes 6 Data Record Option Button When this option is selected the log will display a record of the items that are shown in the main window 7 Closed Application Information Option Button When this option is selected the log will display the names and location of any files that were auto saved by the software TESTING YOUR UPS SYSTEM Once you have set up your UPS system you may wish to test it Make sure that the UPS has been charged for at least 4 hours before performing this test If you are using PowerPanel Plus 1 With your UPS and computer on open an application such as notepad
13. R ensures consistent power to your computer system and includes software that will automatically save your open files and shutdown your computer system during a utility power loss INCONSISTENT Utility Power CONSISTENT Cyber Power 8 N u im Ny l My cane n idh Automatic Voltage Regulators increase low or decrease high ay voltage to a computer safe nas vots The TOOAVR g auto eee ides battery backup power if line voltage y drops balaw olts of exceads 150 volts AUTOMATIC VOLTAGE REGULATOR The CPS700AVR controls utility power voltage levels that can be inconsistent The incoming utility power may be at a damaging level to important data files but with the Automatic Voltage Regulation of the CPS700AVR the computer will only experience a consistent voltage level An Automatic Voltage Regulator automatically increases low or decreases high voltage to a consistent computer safe 110v 120v The powerful 7 5AH battery provide power only if the incoming voltage drops below 85v or increases above 150v CPS700AVR Guaranteed Uninterruptible Power System DESCRIPTION 1 Power on Indicator 6 Serial Port to PC This LED is illuminated when the utility condition is normal and the UPS This port allows connection and communication from the DB 9 serial outlets are providing clean power free of surges and spikes port on the computer to the UPS unit The UPS communicates its 2 Electrical Wiring Fault Indicator
14. R in the United States or Canada the original end user receives a Limited Warranty and CyberPower s Power Control Guarantee from Cyber Power Systems USA Inc for ease of reading referred to as CyberPower The Limited Warranty and the Power Control Guarantee are intended to be the initial end user s exclusive rights and remedies The Limited Warranty and the Power Control Guarantee are separate all though they are related Limited Warranty The original end user referred to as the Initial Customer receives an express limited warranty for the CPS700AVR referred to as the Limited Warranty purchased from CyberPower referred to as the Product The Limited Warranty is for the Product itself The terms of the Limited Warranty are explained below Power Control Guarantee CyberPower also provides the Initial Customer with protection in the event that the Product is not free from defects in materials and workmanship and certain equipment connected to the Product is damaged the Power Control Guarantee The Power Control Guarantee protects the Initial Customer for damage to equipment plugged into the Product The terms of the Power Control Guarantee are explained below The Limited Warranty and the Power Control Guarantee are subject to the terms set forth below Additionally State or Provincial law may adjust the terms of the Limited Warranty or the Power Control Guarantee or the State or Province may impose addition
15. Windows Me Windows NT and Windows 2000 The latest version can be downloaded from www cyberpowersystems com downloads htm It works in conjunction with the UPS to provide full protection of valuable computer systems applications and data In the event of a power failure PowerPanel Plus automatically saves and closes open files under auto assigned file names or existing files names after a software controlled delay The computer and UPS are automatically shutdown to conserve battery power Files with auto assigned names will be saved under C PCTemp where C is the name of your main hard drive Files that have previously been saved will be saved in their original location PowerPanel Plus is equipped with a Schedule feature that can automatically save and close open files and then shutdown the computer and UPS at a user specified date and time as well as start the computer at a user specified date and time Use of this feature is optional and is not required for the power failure shutdown to occur The use of the PowerPanel Plus software is optional The UPS unit will provide full surge suppression and battery backup without the software You must use the software if you wish to have the automatic shutdown feature POWERPANEL PLUS MAIN MENU j min 3 Gh j Log Button Click on the log button to open the Log Window Power Button Clicking on the power button will stop the software Minimize Button Click this button to minimize the
16. aim under any applicable insurance other warranty or extended warranty The Power Control Guarantee is separate from the Limited Warranty but they are related The Limited Warranty does not cover Connected Equipment but as is explained below to be covered under the Power Control Guarantee the Connected Equipment must have been damaged due to a failure of the Product that is covered by the Limited Warranty The Connected Equipment must have been damaged due to a defect in materials or workmanship of the Product and the Product must still be covered by the Limited Warranty and the Initial Customer has made a valid claim for the Product under the Limited Warranty In the event of damage to the Connected Equipment your exclusive remedy and CyberPower s sole obligations are as follows for Connected Equipment If a the Product purchased and owned by you is defective in material or workmanship under the Limited Warranty or any applicable Implied Warranty b the Limited Warranty requirements have been met and c none of the limitations or exclusions on warranty coverage apply CyberPower will as CyberPower elects as permitted by law repair replace or pay the Agreed Damage Amount defined below for the item s of your electronic equipment directly and properly connected to the product the Connected Equipment if that Connected Equipment is x damaged by AC power line transients spikes or surges on properly installed grounded and co
17. al obligations or additional implied warranties To the extent necessary to comply with those laws the terms of the Limited Warranty and the Power Control Guarantee should be read to adjust to those requirements only to the extent necessary to comply with such local law If you are an Initial Customer you are asked to read the following terms and conditions carefully before using the Product By using the Product you consent to be bound by and become a party to the Limited Warranty and Power Control Guarantee If you do not agree to the terms and conditions of the Limited Warranty and Power Control Guarantee you should return the Product for a full refund prior to using it REGISTRATION CyberPower requests that you complete and return the Warranty Registration Card enclosed with the Product or register the Product at its website www cyberpowersystems com to establish that you are the original end user consumer purchaser of the Product and therefore entitled coverage under the Limited Warranty and the Power Control Guarantee Registration is not required for Limited Warranty coverage but note if you do not complete a registration card you will be required to provide proof of purchase as described below to have the benefits of this Limited Warranty LIMITED WARRANTY CyberPower warrants to you the Initial Purchaser that the Product will be free from defects in material and workmanship for three years from the date of original purchase
18. anty registration card 1 UPS unit HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT o_o Make sure that the total Volt Amp VA requirements of your computer monitor and peripheral equipment does not exceed 1440VA 2 Insure that the equipment plugged into the three battery power supplied outlets does not exceed the UPS unit s rated capacity 7O0VA 350W for CPS700AVR If rated unit capacities are exceeded an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip 3 Ifthe power requirements of your equipment are listed in units other than Volt Amps VA convert Watts W or Amps A into VA by doing the calculations below Note The below equation only calculates the maximum amount of VA that the equipment can use not what is typically used by the equipment at any one time Users should expect usage requirements to be approximately 60 of below value TO ESTIMATE POWER REQUIREMENTS Watts W x2 VA or Amps A x 120 VA Add the totals up for all pieces of equipment and multiply this total by 6 to calculate actual requirements There are many factors that can affect the amount of power that your computer system will require The total load that you will be placing on the battery powered outlets should not exceed 80 of the unit s capacity CyberPower HARDWARE INSTALLATION GUIDE oe Circuit Breaker g a a L Your new UPS may be used immediately upon receipt Ho
19. arges the unit will beep more rapidly indicating that the battery is nearing discharge Once the test is complete plug the UPS back in to the AC outlet and start your computer Please allow 4 hours for the UPS to recharge before attempting another self test DEFINITIONS FOR ILLUMINATED LED INDICATORS Eo J Condition On Off AVR AVR is maintaining a consistent 120v level 5 Quickly during a power sag Flash Slowly On Off Off AVR AVR is maintaining a consistent 120v 5 during a power surge EEEE En a Utility Failure The UPS is providing battery power to the Battery Power Supplied outlets S S a Utility Failure The UPS is providing battery power The rapid beeps indicate the battery will run out of charge within a few minutes Two i Overload Occurs in the Full time Surge Protection Outlets Turn the UPS off and unplug at least one piece of equipment from the UPS Wait 5 seconds i rapid eee reset the circuit breaker and turn the UPS on On Off Flash On Off Long Beep Overload Occurs in the Battery power Supplied Outlets Turn the UPS off and unplug at least one piece of equipment from the UPS Wait 5 seconds reset the circuit breaker and turn the UPS on Off Long Beep Overload Occurs in the Battery power Supplied Outlets Turn the UPS off and unplug at least one piece of equipment from the UPS Wait 5 seconds reset the circuit breaker and turn the UPS on Weak Battery Recharge the battery for at least 8 hours If Check Ba
20. berPower 4 Pack and ship the Product to CyberPower as instructed in your Return Material Authorization Show the Return Material Authorization code on the shipping label or include it with the Product You must prepay all shipping costs and you are responsible for packaging and shipment CyberPower will inspect and examine the Product within ten 10 days of receipt If the Product is not as warranted CyberPower will repair or replace the Product and return it to you at CyberPower s expense or if CyberPower is unable to or decides not to repair or replace the Product if defective within a reasonable time CyberPower will refund to you the full purchase price you paid for the Product purchase receipt showing price paid is required POWER CONTROL GUARANTEE If you are the Initial Purchaser and the Product is still covered by the Limited Warranty the Power Control Guarantee provides protection for damage to equipment connected to the Product Connected Equipment subject to certain terms and limitations 10 CPS700AVR Guaranteed Uninterruptible Power System The Power Control Guarantee is not first dollar coverage CyberPower s obligation is reduced by any amounts that Initial Customer is entitled to recover from other sources regarding the Connected Equipment including insurance other warranty or extended warranty coverage whether or not the Initial Customer makes a claim for recovery including but not limited to a cl
21. claim for warranty service 3 When you call write or E Mail identify the Product the Purchase Date and the item s of Connected Equipment Have information on all applicable insurance or other resources of recovery payment that are available to the Initial Customer for the Connected Equipment and the name of the power utility supplier for the location of the Connected Equipment and request Return Material Authorization information from CyberPower 4 Pack and ship the Product to CyberPower and if requested by CyberPower the item s of Connected Equipment a repair cost estimate for the damage to the Connected Equipment and or a written statement of how the damage occurred as instructed in your Return Material Authorization Show the Return Material Authorization code on the shipping label or include it with the Product Initial Customer shall prepay all shipping costs and is responsible for packaging and shipment CyberPower will inspect and examine the Product and the item s of Connected Equipment or at CyberPower s election your written statement and repair cost estimate for those item s You must return the product for inspection If the Product is warranted under the Limited Warranty and the damage to Connected Equipment is covered by the Power Control Guarantee CyberPower will in addition to Limited Warranty remedies for the CyberPower Product itself repair or pay the costs of repair or replace the Connected Equipment or at the option
22. de compliant 120 volt power lines in the United States and Canada or by transients surges or spikes on standard telephone equipment lines or Base 10 100T Ethernet lines that are properly installed and connected a Power Disturbance and y is directly plugged into and properly connected to a CyberPower Product in its original condition which is properly operated when a Power Disturbance passes through the CyberPower Product and y 1 exhausts the protection capacity of the CyberPower Product or y 2 damages the CyberPower Product This provision sets out the only liability of any character of CyberPower for direct indirect special consequential and or incidental damages under our Limited Warranty applies only to Connected Equipment and all such Liability is limited to the Agreed Damage Amount To make a Warranty claim for damage to Connected Equipment under the Power Control Guarantee you must do the following 1 Complete and return the CyberPower Warranty Registration Card or provide reasonable proof for example a sales receipt that establishes you as the Initial Customer the original consumer purchaser of the Product within ten 10 days of the event for which you want to make a claim for warranty service 2 Call CyberPower at 952 403 9500 or write to CyberPower at 5555 12 Avenue East Suite 110 Shakopee MN 55379 or E Mail CyberPower at tech cyberpowersystems com within ten 10 days of the event for which you want to make a
23. er without warranty by the Initial Customer but free of lien or other interest CONDITIONS COMMON TO THE LIMITED WARRANTY AND THE POWER CONTROL GUARANTEE The Limited Warranty and the Power Control Guarantee are the only and the exclusive express warranty of CyberPower with respect to the Product This exclusion of other express warranties applies to written and oral express warranties Any Implied Warranty of Merchantability or for Fitness for a Particular Purpose if applicable to the Product is limited in duration to the period of ownership by the Initial Customer This provision shall NOT create any Implied Warranty or Merchantability or of Fitness for a Particular Purpose that would not Otherwise apply to the Product NOTE Some States do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you 11 CyberPower LIMITATION THE LIMITED WARRANTY AND THE POWER CONTROL GUARANTEE DO NOT COVER The Limited Warranty and the Power Control Guarantee are intended to exclusive rights and remedies and replace any other rights to the extent allowed by law 1 As to CyberPower products the Limited Warranty does not cover or apply to Misuse modification operation or storage outside environmental limits for the Products in transit in shipment or in storage damage or deterioration improper operation or maintenance use with items or equipment not designed or intended for use with the Product 2 As
24. grounded and code compliant 120 volt power lines in the United States and Canada transients surges or spikes on standard telephone land lines PBX telephone equipment lines or Base 10 100T Ethernet lines when properly installed and connected This exclusion applies for example to fluctuations in data transmission or reception by CATV or RF transmission or fluctuations or by transients in such transmission 3 Damage from any circumstance described as excluded above with respect to the Product 4 Damages from fire flood wind rain rising water or leakage or breakage of plumbing from abuse misuse or alteration of either the Product or the Connected Equipment Exclusion of Consequential and Other Damages The sole and exclusive remedies of the Initial Customer are those provided by the Limited Warranty and Power Control Guarantee CyberPower excludes any liability for personal injury under the Limited Warranty and Power Control Guarantee CyberPower excludes any liability for direct indirect special incidental or consequential damages whether for damage to or loss of property loss of profits business interruption loss of information or data EXCEPT FOR AND ONLY FOR the specific limited agreement of CYBERPOWER to provide certain warranty benefits regarding Connected Equipment under the CYBERPOWER Power Control Guarantee NOTE Some States or Provinces do not allow the exclusion or limitation of incidental or consequential da
25. imate Backup Time This indicator shows the approximate amount of backup time that is available based upon the battery capacity and the load on the system This indicator can appear in red yellow or green depending upon the number of minutes available 7 Scheduled Off PowerPanel Plus can be set to automatically shutdown the computer system at a user specified time Scheduled Off settings that are set to occur within seven days will be displayed 8 Temperature This indicator displays the internal operating temperature of the unit If the temperature exceeds 158 F 70 C the indicator will change from green to red RON 9 CPS700AVR Guaranteed Uninterruptible Power System Load Level This indicator shows the of capacity of the battery outlets that is currently being used If the load level exceeds 90 the indicator will change to a red color 10 Output Voltage This indicator shows the output voltage of the UPS POWERPANEL PLUS SETUP WINDOW Sensitive to Variation on Line Voltage This feature is for other CyberPower Products Since the 7OOAVR has Automatic Voltage Regulation this feature is not necessary Auto Restart This feature allows the UPS to restore power to the battery outlets once the power is restored after a power failure Software Broadcast With this option enabled the software will play audible voice messages through your computer speakers A sound card and speakers are required Time Between Po
26. mages so the above limitation may not apply to you DO NOT USE FOR MEDICAL OR LIFE SUPPPORT EQUIPMENT OR OTHER HIGH RISK ACTIVITIES CyberPower does not sell the Products for use in high risk activities The Product is not designed or intended for use in hazardous environments requiring fail safe performance including the operation of nuclear facilities aircraft navigation or communication systems air traffic control weapons systems life support or medical applications or for use in any circumstance in which the failure of the Product could lead directly to death personal injury or severe physical or property damage or that would affect operation or safety of any medical or life support device collectively High Risk Activities CyberPower expressly disclaims any express or implied warranty of fitness for High Risk Activities CyberPower does not authorize use of any of its products use in any High Risk Activities ANY SUCH USE IS IMPROPER AND IS A MISUSE OF CYBERPOWER PRODUCTS The Limited Warranty and the Power Control Guarantee are governed by the laws of the United States and the State of Minnesota without reference to conflict of law principles The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded Contact Information CyberPower s address is 5555 12 Ave East Suite 110 Shakopee MN 55379 and its phone number is 952 403 9500 CyberPower is the warrantor under
27. ng this setting High Voltage Failure Sets the upper level where the UPS will cycle to battery This level can be adjusted from 140v to 150v Low Voltage Failure Sets the lower level where the UPS will cycle to battery This level can be adjusted from 85v to 95v Battery mode Output Voltage Sets the voltage that the unit will output when running on battery This level can be adjusted from 100v to 125v Cold Start When this is enabled the UPS can start in the absence of AC power To maximize battery life it is recommended to keep this disabled Default Restores the settings to the factory defaults Cancel Exits the window without saving changes OK Exits the windows and saves changes Remote On Function This function is not available on this model CyberPower POWERPANEL PLUS SCHEDULE MENU i Special Setting This setting allows you to schedule a one time startup shutdown Schedule Display This area displays the days dates and times of any scheduled startups and shutdowns Turn On Select the day date and time that you want the computer system to restart Can only be used in conjunction with a scheduled shutdown Turn On Disabled When the button states Turn On Disabled the UPS is set to restart in accordance with the schedule When the button states Turn On Enabled the UPS will not restart in accordance with the schedule Clear Clears the selected item from the schedule Add Adds an item to the schedule OK
28. puter O p Ep pra U When your computer restarts the PowerPanel Plus software will appear on your screen for a few seconds and then minimize It will appear as a blue and white battery icon located in the system tray near the clock PowarPanal Plus icon ime BT i Bb seam FOR WINDOWS 2000 Click on Start point to Settings and then click Control Panel Double click on Power Options On the UPS Tab click Select In the UPS Selection Dialog Box under Manufacturers click None Exit to the desktop Shutdown the computer Turn the UPS off and unplug it Connect the serial interface cable to the UPS and an open serial port on the back of your computer Note You must use the cable that was supplied with the unit 8 Plug the UPS into an AC outlet turn the UPS on and then start your computer 9 Windows will find New Hardware 10 Insert the software disk into the floppy drive 11 Follow the on screen instructions 12 Once the software is installed remove the floppy disk and restart your computer oe a ae When your computer restarts the PowerPanel Plus software will appear on your screen for a few seconds and then minimize It will appear as a blue and white battery icon located in the system tray near the clock PowerPandl Flis loon on 6 VEJAS seam CyberPower POWERPANEL PLUS SOFTWARE USER MANUAL OVERVIEW PowerPanel Plus version 1 13 or greater is designed for use with Windows 95 Windows 98
29. subject to the terms of this Limited Warranty To be covered you must still be the owner of the Product at the time of the failure that results in the claim made under this Limited Warranty Your exclusive remedy and CyberPower s sole obligations are as follows for the Product If a the CyberPower Product you purchased and still own is defective in material or workmanship under this Limited Warranty or any applicable warranty imposed by law and b all Limited Warranty requirements have been met CyberPower will repair or replace the Product if it proves to be defective in material or workmanship during the Warranty Period To make a Limited Warranty claim on a Product you must do the following 1 Complete and return the CyberPower Warranty Registration Card or provide reasonable proof of purchase for example a sales receipt that establishes you as the Initial Customer the original end user consumer purchaser of the Product and prove that the Product was purchased within three years of the event for which you want to make a claim for warranty service 2 Call CYBERPOWER at 952 403 9500 write to CYBERPOWER at 5555 12 Avenue East Suite 110 Shakopee MN 55379 or E Mail CYBERPOWER at tech cyberpowersystems com within ten 10 days of the event for which you want to make a claim for warranty service 3 When you call write or E Mail identify the Product the Purchase Date and request Return Material Authorization information from Cy
30. ttery is illuminated contact CyberPower Systems for battery replacement information a Scheduled Turn on If the two battery indicators are flashing in rotation the UPS is waiting to turn on as configured in the schedule Cold Start Disabled If the two battery indicators are flashing at the same time the cold start has been disabled The UPS will not start in the absence of AC power On Off On Off Set Up None Electrical Wiring Fault This indicates a wiring a problem such as a bad ground missed ground or reversed wiring within the AC outlet User is advised to disconnect all electrical equipment from the outlet and have the outlet checked by an electrician Cy berPower TROUBLESHOOTING Full time surge protection Circuit breaker has tripped due Turn the UPS off and unplug at least one piece of equipment outlets stop providing power to to an overload Wait 10 seconds reset the circuit breaker by depressing the equipment button and then turn the UPS on The UPS does not perform Battery not fully charged Recharge the battery by leaving the UPS plugged in expected runtime Battery is slightly worn out Contact CyberPower Systems about replacement batteries at tech cyberpowersystems com The UPS will not turn on The on off switch is designed to Turn the UPS off Wait 10 seconds and then turn the UPS on prevent damage by rapidly turning it off and on The unit is not connected to an The unit must be connected to a 1
31. uce the risk of electric shock do not remove the cover secured by star shaped screws No user serviceable parts are inside except for the battery Refer servicing to qualified personnel CAUTION The battery can energize hazardous live parts inside even when the AC input power is disconnected CAUTION UPS must be connected to an AC power outlet with fuse or circuit breaker protection Do not plug into an outlet that is not grounded If you need to de energize this equipment turn off and unplug the unit CAUTION To avoid electrical shock turn off the unit and unplug it from the AC power source before servicing the battery or installing a computer component DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT CyberPower Systems does not sell products for life support or medical applications or for use in any circumstance that would affect operation or safety of any medical for life support or medical applications or patient care DO NOT USE WITH OR NEAR AQUARIUMS To reduce the risk of fire or shock do not use with or near aquariums Condensation from the aquarium can come in contact with the unit and cause the unit to short out WHAT IS AVR This machine provides complete power protection from utility power that is not always consistent The CPS700AVR features a high level of surge suppression 825 Joules for power line surges and provides long lasting battery backup with a 7 5AH battery for loss of utility power and voltage sags The CPS700AV
32. upplied with the unit Plug the UPS into an AC outlet turn the UPS on and then start your computer Windows will find New Hardware Insert the software disk into the floppy drive Follow the on screen instructions Once the software is installed remove the floppy disk and restart your computer N NO ORO When your computer restarts the PowerPanel Plus software will appear on your screen for a few seconds and then minimize It will appear as a blue and white battery icon located in the system tray near the clock Fwar Panal Flis loon Dij 6 i La ee eae niian FOR WINDOWS NT Click on Start point to Settings and then click Control Panel Double click on the UPS Icon Remove the check mark from the box labeled UPS is installed on Click OK Acknowledge the message that the UPS is in an unknown state Exit to the desktop Shutdown your computer Turn the UPS off and unplug it Connect the serial interface cable to the UPS and an open serial port on the back of your computer Note You must use the cable that was supplied with the unit 10 Plug the UPS into an AC outlet turn the UPS on and then start your computer 11 Click on Start point to Settings and then click Control Panel 12 Double click on Add Remove Programs 13 Insert the software disk into the floppy drive 14 Click Install 15 Follow the on screen instructions 16 Once the software is installed remove the floppy disk and restart your com
33. wer Failure and Shutdown This is the user controllable delay between when the power fails and the software starts the shutdown process If unchecked the unit will run on battery until the low battery signal is received 2 minutes of backup time remaining and then start the shutdown process Time Between Power Failure and Initial Warning This setting determines the delay between when the power fails and the first audible alarm Delay Between Warning Messages User adjustable setting for the delay between the audible alarms that occur during a power failure UPS Self Test Allows the user to test the UPS without having to unplug the unit from the wall When Run is clicked the will switch to battery power and the unit will beep About This button will display information about the software as well as contact information Advance This button opens the Advanced Setup Window Default Click this button to return the software to original factory settings Cancel This button exits the window without saving changes OK This button exits the window and saves changes UPS is Installed On This shows the COM port that the UPS is using The port assigned to the UPS needs to be used exclusively for the PowerPanel Plus software Buzzer This toggles the audible alarm on and off POWERPANEL PLUS ADVANCED SETUP aay gt OND Low Battery Voltage This sets the low battery cutoff level The user can slightly extend the UPS run time by adjusti
34. wever recharging the battery for at least four hours is recommended to insure that the battery s maximum charge capacity is achieved Charge loss may occur during shipping and storage To recharge the battery simply leave the unit plugged into an AC outlet The unit will charge in both the on as well as the off position If you wish to use the software connect the enclosed serial interface cable to the serial port on the UPS and an open serial port on the computer If you are not going to use the software you do not need to connect the cable With the UPS unit off and unplugged connect your computer and monitor into the battery power supplied outlets Plug your peripheral equipment printer scanner speakers into the full time surge protection outlets DO NOT plug a laser printer copier space heater vacuum or other large electrical device into the UPS The power demands of these devices will overload and possibly damage the unit IN i ail Wall Jack To protect a fax telephone or modem line connect a telephone cable from the wall jack outlet to the in jack of the UPS Connect a telephone cable the out jack on the UPS with the CPU icon to the modem port of the computer The out jack with the telephone icon can be used to protect a telephone or fax machine line f Circuit Breaker Plug the UPS into a 2 pole 3 wire grounding receptacle wall outlet Make sure the wall branch outlet is protected by a fuse or
35. with insulated handles Do not lay tools or metal parts on top of battery or any terminals Wear rubber gloves and boots Determine if the battery is inadvertently grounded If inadvertently grounded remove source of ground CONTACT WITH GROUNDED BATTERY CAN RESULT IN ELECTRICAL SHOCK The likelihood of such shock will be reduced if such grounds are removed during installation and maintenance applicable to a UPS and a remote battery supply not having a grounded circuit oP a TO REPLACE THE BATTERY Turn off and unplug all connected equipment Turn the UPS off and unplug it from the AC power source Turn the UPS upside down Remove the 4 retaining screws Turn the UPS right side up and remove the cover Remove the battery from the compartment Disconnect the battery wires from the battery Install the replacement battery by connecting the red wire to the positive terminal of the battery and connecting the black wire to the negative terminal of the battery 9 Slide the battery back into the compartment 10 Replace the outlet cover and the 6 retaining screws 11 Recharge the unit for 4 8 hours to ensure the UPS performs expected runtime Sea eT REMINDER Batteries are consider HAZARDOUS WASTE and must be disposed of properly Contact your local government for more information about proper disposal and recycling of batteries CyberPower Limited Warranty And Power Control Guarantee In purchasing a CPS700AV

Download Pdf Manuals

image

Related Search

Related Contents

Benq MP626 data projector  User Manual - TuneUp Utilities  PlasmaSync® 50MP1  M-Cab 7001232 mounting kit  クリックロガー取扱説明書(PDFファイル)  Audit Tool User Guide - Bournemouth University  Teknokroma Analítica S.A. Camí de can Calders 14, 08173  Krups 872 User's Manual  Manuel d`utilisation / User manual BM  Dataram DRSX4470M2L/16GB memory module  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.