Home
3. Plant description and technical data
Contents
1. lt 20cm L b nach q2 DIN 4124 5 2 S eg 0 3 S kW BEE EE all rall gt 70cm gt 70cm Subbase Round grain gravel max graining 8 16 acc to DIN 4226 1compacted with Dpr295 2 Tank bed compacted sand Aqabase GO Tank encasing Round grain gravel max graining 8 16 acc to DIN 4226 1compacted with Dpr2 95 GG Area outside tank encasing material of suitable consistence Top layer Topsoil or similar outlet pipes must also be routed at a frost free depth when the rainwater storage tank is installed Unless otherwise spe cified by the authorities the frost free depth is as a rule lo cated at approx 80 cm 5 4 Tests before installation Immediately before placing the tank into the excavation pit the technical expert of the company that has been commis sioned to carry out the installation has to check and certify the following The sound condition of the tank wall The proper condition of the excavation pit with a view to its dimensions and base bedding Consistence of the filling material graining
2. 5 5 Installation To avoid deformation of the tank filling the tank with water and backfilling the excavation pit should general ly be carried out at the same time and quickly ik KESSEL 5 Installation and assembly Placement The tanks must be placed shock free into the excavation pit with the aid of suitable equipment and put down onto the base bedding see also chapter Transport Filling the tank Fill the tank up to the outlet with water Backfilling excavation pit The tank encasing must be produced in a width of at least 50 cm The individual layers should not exceed a height of 30 cm They must be compacted using light compacting equip ment Dpr2 95 Damage to the tank wall and a dislocation of the tanks during and after installation must be ruled out Connection of the tank a Once the excavation pit has been filled up to the lower edge of the inlet and outlet pipe connections and com pacted the inlet and outlet pipes and the empty conduit required for the power and water pipes must be laid frost free in the case of year round use and connected When laying the empty conduit simply remove the KG socket plug DN 150 and lay the KG empty conduit in DN 150 for the power and water pipes from the rainwater storage tank to the rainwater pumping station or to the house at a gra dient and place a socket DN 150 at the end on the insi de cellar wall This allows the backwater proof KESSEL empty
3. Transport must only be carried out by companies who are in possession of the technical experience suitable imple ments equipment and means of transport as well as ade quately trained personnel The tanks must be transported such that they are not sub ject to undue stresses and that a dislocation during trans port is ruled out If restraints are used these must be atta ched such that damage to the tanks is ruled out e g use of canvas belts hemp ropes The use of wire ropes or chains is not permissible Transport of 3000 4500 I 6000 tanks ik KESSEL When lifting transporting and putting down the tanks im pact loads must be avoided If a fork lift is used the tanks must be secured while they are transported on the fork lift Muffs and other projecting tank parts must not be used for attachment or for lifting purposes It is not permissible to roll or drag the tanks across the floor The tanks must be secured against undue dislocations du ring transport The manner of fastening may not damage the tanks 4 3 Storage If it is necessary to store the tanks prior to installation this may only be done temporarily and on level ground that has been cleared of any sharp edged objects In case of outdo or storage the tanks must be protected against damage ex posure to storms and soiling 18 5 Installation and assembly During the intermediate storage of the rainwater stora ge tank and until compl
4. and KG socket plug Instructions for installation operation and maintenance The rainwater storage tank can be used in areas driven over by cars The limits of soil cover in the area that can be walked on are 500 mm lt DSC lt 1500 mm and in the area than can be driven over at 700 mm lt s DSC lt 1500 mm The soil cover DSC corresponds to the clearance between the gro und level and the back of the rainwater storage tank The parts listed in the Accessories chapter can be retro fitted Installation in groundwater The maximum water level must not rise above the base di mension of the standard outlet even briefly To guarantee safety from buoyancy the soil cover layer must be at least 700 mm thick The information in chapter 5 Installation and assembly must be strictly followed Backwater occurs when soils that only allow little water to permeate prevent seepage water flowing away Backwater is formed parti cularly after heavy rain or when snow melts ik KESSEL Installation in areas that can be driven over Class D When the tanks are installed in areas that can be driven over Class D aconcrete base plate must be placed over the rainwater storage tank A formwork plan and reinfor cement drawing can be provided on request The parts listed in the Accessories chapter can be retro fitted Pre scored areas On the ends and the back max DN 150 see in illustra tion Other points are no
5. Separators iki KESSEL
6. conduit seal to be fitted correctly later The empty conduit must be kept as short as possible Unnecessary changes in direction must be avoided To make it easier to pass cables and pipes through later bends gt 45 must be avoided b Laying with gradient When inlet pipes are laid from the rainwater filter drainpipe to the cistern and from the over flow connection to the sewer connection or to seepage care must be taken that there is sufficient gradient in the direction of flow according to DIN 1986 c Backwater protection for sewer connection If the overflow connection of the rainwater storage tank is connected to the public sewer it must be protected from backwater according to DIN 1986 either by a lifting station or by free gradient to the sewer or alternatively through a backwater valve according to DIN 1997 for wastewater free of sewage rainwater When a backwater valve is used care must be taken that the emergency valve always remains open to guarantee draining against the sewer backwater even in the event of backwater In addition a rat protection gate can be retrofitted d Aerating and ventilating the rainwater storage tank The KESSEL rainwater storage tank Aqabase must be sufficiently aerated and ventilated to guarantee safe ope ration One of the four possibilities 1 4 see illustration must be realised The pipe nominal width DN 100 ik KESSEL should be kept short always be on the rise and sealed b
7. dimension H3 even briefly To guarantee safety from buoyancy the soil cover layer must be at least 700 mm thick The infor mation in chapter 5 Installation and assembly must be Strictly followed Backwater occurs when soils that only allow little water to permeate prevent seepage water flowing away Backwa ter is formed particularly after heavy rain or when snow melts Maximum permanent load on the cover is 50 kg Note 3000 4500 6000 The limits of soil cover in the area that can be walked on are 500 mm lt DSC lt 1500 mm and in the area than can ik KESSEL be driven over at 700 mm lt DSC lt 1500 mm The soil cover DSC corresponds to the clearance between the gro und level and the back of the rainwater storage tank Note 9000 I The limits of soil cover are at 200 mm lt DSC lt 1500 mm The parts listed in the Accessories chapter can be retrofitted Pre scored areas On the ends and the back max DN 150 see in illustration Complete dome area max 3 max DN 150 minimum cen tre 90 see illustration Other points are not allowed without the agreement of the manufacturer Only use the KESSEL saw cap for scoring the openings see Accessories chapter Only use KESSEL seals for ducts for sealing see Accesso ries chapter Art Nr 85460B cupola area D Be Be Q O Remark To achieve optimum sealing of the bore hole the clearance between the edge of the bore ho
8. 3 and 9 m3 useful volume The main advantage of the 100 recyclable and light material PE is its easy placement in the excavation In addition the KESSEL rainwater stora ge tank is a monolithic tank that is absolutely impermeable to water and resistant to acid rain To achieve greater useful volumes the rainwater storage tanks can be installed and piped parallel in series 6 Rainwater pumping system Aqabull with Switch unit Agatronic S D Service water network 3 Plant description and technical data 3 1 KESSEL Rainwater storage tank Aqabase For outdoor use Art Nr 85460 Art Nr 85490 Condition on delivery scope of supply Tank in mint green colour with baffle for inlet slowdown Cover secured against unauthorised opening childproof Screw attachment of the cover with the dome area through 3 hexagon stainless steel bolts DIN 571 5 x 70 mm offset by 120 degrees 2 seals for pipe duct DN 100 Instructions for installation operation and maintenance The rainwater storage tank may only be installed outdo ors in an area that is not driven over Retrofitting with attachment pieces that can be driven over does not in crease the possible load capacity Aqabase for outdoor use is suitable in soil that can absorb rain and allow it to seep in or is free of groundwater Installation in groundwater or backwater is not possible Backwater occurs when soils that only allow little water to p
9. 33 860 121 860 116 85 412 With two seals each DN 32 DN40 one seal DN 50 and one blind plug each DN 40 and DN 50 Suitable for KESSEL rainwater pumping systems Agabull Aqadive and rainwater filters with without back flushing unit ik KESSEL 23 8 Accessories Article Order Nr KESSEL inlet slowdown 100 85 418 made of polyethylene 100 with branch 100 90 To slow down the rainwater flow into the rainwater storage tank 45001 9000 vw 6000 8 3000 KESSEL overflow siphon 100 85 419 made of polyethylene 100 For optimum removal of floating material 3000 4500 90001 vw M ZS 6000 ik KESSEL 24 8 Accessories Article Order Nr KESSEL stickers Not drinking water 85073 for marking the pipes as non drinking water pipes KEIN TRINKWASSER Lx B 26 x 80 mm NOT DRINKING WATER 5 pcc box EAU NON POTABLE AQUA NON POTABILE KESSEL sign Not drinking water for marking the tapping points L x W 60 x 120 mm neg 2 pcc box In diesem Geb ude Serien KESSEL sign No cross connection to the drinking water network serene aa en et heed DIN 1988 E for attachment near the water meter L x W 105 x 148 mm 1 pc box KESSEL saw cap 50 100 For scoring the openings for pipe duct seals DN 50 70 100 125 150 Seal for pipe duct 50 850114 70 850116 100 850117 125 850118 150 850119 KESSEL s
10. 4 Inlet for filtered rainwater 5 Outlet to the sewer seepage Empty conduit connection 7 Attachment piece 12 3 Plant description and technical data Dimensioned drawing Erd berdeckung Ten T 140 mm Te Class A B Class D S000 Liter 470 w am ve 85490 808 0 all dimensions in mm Base dimension Installation suggestion the chapter Installation and assembly must be taken into account G Inlet DN 100 i Outlet DN 100 i Empty conduit connection DN 100 with compensation DN 150 1 Rainwater storage tanks Aqabase Komfort 2 Inlet slowdown 3 Overflow siphon 4 Inlet for filtered rainwater 5 Outlet to the sewer seepage Empty conduit connection 7 Attachment piece iki KESSEL 13 3 Plant description and technical data 3 4 KESSEL Rainwater storage tank Aqabase Multicompact Condition on delivery scope of supply Tank grey Telescopic height adjustment of attachment piece Cover Class B according to EN 124 made of cast iron lock able surface waterproof with lift out key Secured against unauthorised opening by 3 inner hex bolts Inlet DN 100 with integrated rainwater filter System 400 with back flushing unit and inlet slowdown connection through slip on sleeve Outlet DN 100 with overflow siphon and backwater valve with integrated rat protection connection through pointed end Empty conduit connection DN 150 with seal for pipe duct
11. Di Page 5 4 Tests before mstallaton Page ET e Page 6 Installation Service and mantenance Page EN TC Te GE Page EEN ee Page Declaration of conformity oiicccccccceccecceceeceeececescceeesseeseeseeseesesseeseeseesensensnveneeneaneen Page Handover Cetificate e Page Dear customer we are pleased that you have decided to buy a KESSEL product The entire plant was subjected to a stringent quality control before it left our factory Nevertheless please check imme diately whether the plant has been delivered to you complete and undamaged In case of any transport damage plea se refer to the instructions in the chapter Warranty in this manual These installation operating and maintenance instructions contain important information that has to be observed during 2 4 11 14 16 18 18 18 19 19 19 19 19 21 21 22 26 2 installation assembly operation maintenance and repair Prior to carrying out any work on the plant the operator and the responsible technical personnel must carefully read and heed these instructions Important The information values specifications etc given in these instructions for installation operation and mainte nance cannot be transferred to other products on account of the tested statics KESSEL AG ik KESSEL 2 Application Area The KESSEL rainwater storage tank Aqabase is used for For collecting rainwater This is used for the service water supply to private house
12. INSTALLATION OPERATING AND MAINTENANCE INSTRUTIONS KESSEL Rainwater storage tank Agabase for outdoor use Art Nr 85430 85445 85460 85490 Standard 85430B 85445B 85460B 85490B Comfort 85430 80B D 85445 80B D 85460 80B D i 85490 80B D Multicompact 85530 80B D 85545 80B D 85560B D OREINA 85630 80B D 85645 80B D 85660B D Product advantages m Easy placement in the excavation possi ble without a crane being necessary Numerous pre scored areas for various connection possibilities Material is recycling friendly m Absolutely waterproof thanks to seam less monolithic structure Nationwide service network picture shows 85490B The installation and service of this unit should be carried out by a licensed professional servicer Name Sign Subject to technical amendment 1 Safety instructions The personnel for installation assembly operation maintenance and repair must possess the ap propriate qualification for this type of work The area of responsibility the authority and the super vision of personnel must be exactly regulated by the operator The operational security of the plant supplied is only guaranteed when it is used in accordance with the regulations The limits of the technical specifications may not be exceeded on any account During installation assembly operation maintenance and repair of the plant the regulations for the prevention of accidents
13. Liter 335 835 80 110 85660 80B D Hap With a storage volume for the rainwater using Vol A in Liter a 1000 1500 2000 2500 3000 3500 4500 4500 5000 5500 6000 470 650 820 1050 1155 lt a ee ee SE 500 670 820 950 1090 1280 1500 1675 Ps ae 440 560 700 800 890 1000 1130 1220 a 1530 1675 all dimensions in mm Base dimension Mean dimension of scored areas Installation suggestion the chapter Installation and assembly must be taken into account KESSEL Rainwater storage tank Aqabase Retention for the intermediate storage of rainwater 1 Inlet for filtered rainwater 2 Inlet slowdown 3 Throttled outlet outlet quantity from 0 1 1 I s fixed ex factory 4 Free outlet 5 Overflow siphon 6 Outlet to the sewer seepage Q Empty conduit connection Ventilation possibility 1 Scored area for connection for larger useful volume Vol A Storage volume for rainwater use Vol PB Retention volume is discharged throttled to the sewer seepage after heavy rain Total volume Vol A Vol B ik KESSEL 17 4 Packaging Transport and Storage The chapter Safety instructions must be heeded 4 1 Packaging Packaging the tanks for the purpose of transport or storage is not necessary if the following points are observed Note The ingress of impurities dirt dust etc into the rain water storage tank must be avoided If necessary covers must be attached to all openings 4 2 Transport
14. The foundation soil must be horizontal and level so that the system can be put down onto its full surface in addition the foundation soil must guarantee a sufficient load bearing ca pacity As subbase a compacted round grain gravel max graining 8 16 thickness minimum 30 cm Dpr295 and on top of that 3 10 cm compacted sand are necessary The clearance between excavation pit wall and tank must be at least 70 cm The slopes must comply with DIN 4124 The depth of the excavation pit must be dimensioned in such a way that the limits of soil cover are not exceeded MIN lt DSC lt MAX see the chapter Technical Data 19 Installation in terrain with a sloping location When installing the rainwater storage tank in terrain with a sloping location care must always be taken that the lateral ly thrusting soil pressure of disturbed ground is absorbed by a correspondingly designed retaining wall Connecting several rainwater storage tanks If several tanks are installed next to one another behind one another the clearance between the tanks must be at least 70 cm Frost free depth for use all year round When installing the rainwater storage tank it is imperative to pay attention to the locally determined frost free depth To guarantee problem free operation in winter too the inlet and e kb SEENEN hein Bai SES BEL we ony Ce gt
15. a ce the product or it is economically unfeasible to repair or re place the product the customer has the right to cancel the order contract or reduce payment accordingly KESSEL must be notified immediately in writing of defects in a product In the case that the defect is not visible or difficult to detect KESSEL must be notified immediately in writing of the defect as soon as it is discovered If the product is repaired or re placed the newly repaired or replaced product shall receive a new warranty identical to that which the original defective product was granted The term defective product refers only to the product or part needing repair or replacement and not necessarily to the entire product or unit KESSEL products are warranted for a period of 24 month This warranty period be gins on the day the product is shipped form KESSEL to its cu stomer The warranty only applies to newly manufactured products Additional information can be found in section 377 of the HGB 21 In addition to the standard warranty KESSEL offers an addi tional 20 year warranty on the polymer bodies of class Il fuel separators grease separators inspection chambers wa stewater treatment systems and rainwater storage tanks This additional warranty applies to the watertightness usability and structural soundness of the product Arequirement of this additional warranty is that the product is properly installed and operated in accordance with the
16. and the pertinent standards and directives must be heeded These are among others e Accident prevention regulations e Construction work BGV C22 e Technical wastewater systems GUV V C5 e Safety regulations for working in enclosed spaces of technical wastewater systems GUV R 126 e Handling biological working materials in technical wastewater systems GUV R 145 e Directives for working in tanks and narrow spaces BGR 117 e Standards e Excavations and trenches slopes planking and strutting breadths of working spaces DIN 4124 e Construction and testing of drains and sewers DIN EN 1610 Tool for safety and health protection in technical wastewater systems Warning e Hazards through gases and vapours such as risk of suffocation risk of poisoning and risk of explosion e Risk of falling e Risk of drowning e Germ pollution and wastewater with sewage e High physical and psychic strain during work in deep narrow or dark spaces e and others Warning Non compliance with the operating instructions may result in considerable damage to property personal injuries or fatal accidents Caution The system represents one component in a whole plant Please therefore also heed the operating instructions for plant as a whole and the individual components During assembly maintenance service and repair work on one of the components the plant as a whole must always be put out of operation and secured against unintentional restart Conversions or chan
17. ermeate prevent seepage water from the excavation flo wing away Backwater is formed particularly after heavy rain or when snow melts Maximum permanent load on the cover is 50 kg Note 3000 4500 6000I The limits of soil cover are at 500 mm lt DSC lt 1000 mm Note 9000I The limits of soil cover are at 200 mm lt s DSC lt 1000 mm The soil cover DSC corresponds to the clea rance between the ground level and the back of the rain water storage tank The parts listed in the Accessories chapter can be retro fitted Pre scored areas On the ends and the back max DN 150 see in illustra tion Complete dome area max 3 max DN 150 minimum centre 90 see illustration Other points are not allowed without the agreement of the manufacturer Only use the KESSEL saw cap for scoring the openings see Accessories chapter Only use KESSEL seals for ducts for sealing see Accessories chapter Art Nr 85460 cupola area D Be De Q j O Remark To achieve optimum sealing of the bore hole the clearance between the edge of the bore hole and uneven contour should not be less than 15 mm 15 15 mm mm ik KESSEL 3 Plant description and technical data Dimensioned drawing 3000 Liter 1200 1785 4500 Liter 1760 2300 6000 Liter 1760 2300 all dimensions in mm Mean dimension of scored areas Installation suggestion the chapter Installation and a
18. etion of the installation work suitable safeguarding measures must be taken at the building site to prevent accidents and damage to the rainwater storage tank The chapter Safety instructions must be heeded 5 1 Installation conditions Installation must only be carried out by companies who are in possession of the technical experience suitable imple ments and equipment as well as adequately trained person nel A measurement of the soil conditions with a view to its structural suitability must have been carried out soil classi fication for structural purposes DIN 18196 The maximum occurring groundwater or backwater level must be establis hed Installation in groundwater or backwater Install max Ground minima Height possibly water level above ground Te Aqabase for the Green area Aqabase yes 700 mm till outboard wing Standard alternatively Comfort Dimension H3 Multikompakt Retention A sufficient drainage of seepage water is compulsory for soils that are impermeable to water The types of loads oc curring such as maximum travelling loads and installation depth must have been clarified 5 2 Filling material Subbase Round grain gravel max graining 8 16 acc to DIN 4226 1 Tank bed sand Tank encasing Round grain gravel max graining 8 16 acc to DIN 4226 1 Area outside the Tank encasing Top layer material of suitable consistence Topsoil or similar 5 3 Excavation pit
19. ges to the plant may only be carried out in agreement with the manufacturer For safety reasons use original spare parts and accessories approved by the manufacturer The use of other parts may void the liability for any consequences arising thereof The cover on the rainwater storage tank must be sufficiently secured against unauthorised ope ning in particular by children The system does not influence the quality of the service water In the case of backwater wastewater from the sewer can be pushed back into the service water network The service water is not suitable for consumption and personal hygiene Signs saying Caution Not drinking water must be attached to all tapping points ik KESSEL EIER mere oh CC EE NA E LO CS Page 2 Application CT WEE Page 3 Plant description 3 1 Rainwater storage tank Agqabase for outdoor use Page and technical data 3 2 Rainwater storage tank Agqabase Standard Page 3 3 Rainwater storage tank Agabase Komfort Page 3 4 Rainwater storage tank Agabase Multicompact Page 3 5 Rainwater storage tank Agabase Retention Page 4 Packaging transport and storage 4 1 Packaging Page A 2 TRANSQOMN siise anea ea na noaea Se Page A O Le E E scones Page 5 Installation and assembly 5 1 Installation conditions eeen Page 5 2 Filling material sicccehisiienanncshsisduatesssvnserscereretoceiaiviannesteihs Page 5 3 Excavation
20. gn matter and flushed If an empty conduit Service and maintenance The KESSEL rainwater storage tank Aqabase has to be checked every six months by the operator cleanness air tightness sturdiness and safety against unauthorised ope ning If necessary the tank must be serviced by a specialist com pany Normally servicing is only required every 5 10 years During servicing the following procedure should be followed Empty the tank Clean the inside walls of the tank the built in components attachments and cover using a soft brush and water with out cleaning agents Empty the tank completely has been laid between the rainwater storage tank and the building suitable measures e g empty conduit sealing must be taken to ensure that no water can enter the building through the empty conduit The backwater level must be taken into account The additional components required for rainwater use should be installed and tested before initial operation Check the function of the built in components overflow si phon inlet slowdown floating switch etc Fill the rainwater storage tank up to about 30 cm with drin king water service water Secure the rainwater storage tank cover against unautho rised opening 7 Warranty 1 In the case that a KESSEL product is defective KESSEL has the option of repairing or replacing the product If the product remains defective after the second attempt to repair or repl
21. holds public facilities as well as trade and industry Depending on the quality the service water can be used for a wide range of different uses In private households for flushing toilets watering gardens for cleaning and washing clothes In public facilities for flushing toilets as cleaning water and for watering green areas Numerous commercial and industrial applications are conceivable In addition to the sanitation area and for watering lawns gar den areas the service water can also be used for washing and cleaning processes air conditioning plants and as process water The connected rain collecting areas must be evaluated depending on the system technology and soiling level The service water is not suitable for consumption and per sonal hygiene Caution not drinking water For the intermediate storage of rainwater By installing rainwater storage tanks with connected seepage larger quantities of rainwater can be kept out of the sewage sy stem and negative effects can be avoided Jo collect spring water groundwater and river water 1 Drainpipe 2 Rainwater filter System 400 3 Rainwater storage tank Aqabase Komfort 6000 4 Coarse intake filter floating iki KESSEL GG Empty conduit seal DN 150 For other applications Ask us about tailor made solutions for your requirements The KESSEL rainwater storage tanks Aqabase made of PE LLD are supplied in different sizes with 3 m3 4 5 m3 6 m
22. le and uneven contour should not be less than 15 mm 15 15 mm mm 3 Plant description and technical data Dimensioned drawing _ Weight GECKEN E 3000 Liter 1200 1785 1425 1205 1130 110 500 2857 85430B 4500 Liter 1760 2300 1940 1735 1670 150 500 2282 85445B 500 6000 Liter 1760 2300 1940 1735 1670 150 3062 85460B all dimensions in mm Mean dimension of scored areas Installation suggestion the chapter Installation and assembly must be taken into account Q Rainwater storage tank Aqabase Standard 2 Baffle for inlet slowdown 3 Childproof cover that can be walked on GO Inlet 5 Outlet ik KESSEL Plant description and technical data Dimensioned drawing good titer 2010 2870 2170 150 ve CICI 3470 aso 854008 all dimensions in mm Installation suggestion the chapter Installation and assembly must be taken into account 1 Rainwater storage tank Agabase Standard 2 Childproof cover that can be walked on 3 Inlet 4 Outlet ik KESSEL 3 Plant description and technical data 3 3 KESSEL Rainwater storage tank Aqabase Comfort Art Nr 85460 80B Art Nr 85490 80B Condition on delivery scope of supply Tank grey Telescopic height adjustment of attachment piece Cover Class B according to EN 124 made of cast iron lock able surface waterproof with lift out key Secured against unautho
23. rised opening through 3 square bolts Inlet DN 100 with integrated inlet slowdown connection through slip on sleeve Outlet DN 100 with integrated overflow siphon connection through pointed end Empty conduit connection DN 150 with seal for pipe duct and KG socket plug Instructions for installation operation and maintenance The rainwater storage tank can be used in areas driven over by cars Note 3000 4500 6000I The limits of soil cover in the area that can be walked on are 500 mm lt DSC lt 1500 mm and in the area than can be dri ven over at 700 mm lt DSC lt 1500 mm The soil cover DSC corresponds to the clearance between the ground level and the back of the rainwater storage tank Note 9000I The limits of soil cover are at 200 mm lt DSC lt 1500 mm Installation in groundwater Installation in groundwater or backwater is possible The maximum water level must not rise above the dimension H3 even briefly To guarantee safety from buoyancy the soil cover layer must be at least 700 mm thick The infor mation in chapter 5 Installation and assembly must be 11 strictly followed Backwater occurs when soils that only allow little water to permeate prevent seepage water flo wing away Backwater is formed particularly after heavy rain or when snow melts Installation in areas that can be driven over Class D When the tanks are installed in areas that can be driven over Class D a concre
24. ssembly must be taken into account 1 Rainwater storage tank Aqabase for the green area 2 Baffle for inlet slowdown 3 Childproof cover that can be walked on 4 Inlet 5 Outlet ik KESSEL 3 Plant description and technical data Dimensioned drawing all dimensions in mm Mean dimension of scored areas Installation suggestion the chapter Installation and assembly must be taken into account 1 Rainwater storage tank Agabase for the green area 2 Baffle for inlet slowdown 3 Childproof cover that can be walked on GO Inlet 5 Outlet ik KESSEL 3 Plant description and technical data 3 2 KESSEL Rainwater storage tank Aqabase Standard Art Nr 85460B Art Nr 85490B Condition on delivery scope of supply Tank in grey colour with baffle for inlet slowdown Cover secured against unauthorised opening childpro of Screw attachment of the cover with the dome area through 3 hexagon stainless steel bolts DIN 571 5 x 70 mm offset by 120 degrees 2 seals for pipe duct DN 100 Instructions for installation operation and maintenance The rainwater storage tank may only be installed outdo ors in an area that is not driven over The tank can be used in areas driven over by passenger cars by being retrofit ted with KESSEL attachment pieces that can be driven over Installation in groundwater or backwater is possible The maximum water level must not rise above the
25. surface Protects the pump from suctioning in damaging particle sizes Large flow possible thanks to high quality non return valve KESSEL suction coarse filter floating 85 051 for suctioning rainwater from rainwater storage tanks floating version with floating ball made of PE with suction hose 8m long standard suction hose and connec tion and hose fitting filter body with filter made of stainless steel mesh width 1 2 mm all connections 1 inch with backflow protection device EZ Sc eg Le oo e Guarantees suctioning of the cleanest water about 15 cm underneath the water surface Large flow possible thanks to high quality non return valve ik KESSEL 22 8 Accessories Article Art Nr 85 412 KESSEL polyethylene adapter Suitable for all KESSEL Agabase rainwater storage tanks Extension height 510 mm Extension height 1010 mm KESSEL lip seal DN 600 KESSEL cover plate made of plastic For custoamry concrete rings BEGU Covers telescopic adjustable from 40 to 300 mm KESSEL lip seal DN 600 KESSEL cover plate made of GG Class B lockable Can be driven on by cars up to 12 5 t KESSEL plastic attachment piece With clamping ring telescopic height adjustment from 100 to 600 mm for cover Class A B D lockable KESSEL lip seal DN 600 KESSEL empty conduit seal DN 150 made of plastic Order Nr 917 406 917407 860 116 860 122 860 116 860 1
26. t allowed without the agreement of the manufacturer Only use the KESSEL saw cap for scoring the openings see Accessories chapter Only use KESSEL seals for ducts for sealing see Accessories chapter Remark To achieve optimum sealing of the bore hole the clearance between the edge of the bore hole and uneven contour should not be less than 15 mm 15 15 mm mm 3 Plant description and technical data Dimensioned drawing 3000 Liter 1785 4500 Liter 2300 6000 Liter 2300 3000 Liter 4500 Liter 6000 Liter all dimensions in mm 1425 1945 1945 835 835 835 Erd berdeckung Tey T 265 mm 1155 1420 1130 1675 1945 1670 1675 1945 1670 Weight in kg Aqabase Attachement Fixtures CLASS A B CLASS D 190 107 148 85530 80B D 270 107 148 85545 80B D 370 107 148 85560 80B D Base dimension Mean dimension of scored areas Installation suggestion the chapter Installation and assembly must be taken into account 15 KESSEL Rainwater storage tank Aqabase Multicompact with rainwater filter and backwater valve Q Inlet for unfiltered rainwater 2 Rainwater filter System 400 3 Filtered rainwater to the tank GO Soiled water to the sewer for seeping 5 Inlet slowdown Overflow siphon D Empty conduit connection Outlet to the sewer seepage 9 Backwater valve Ventilation possibility OD Scored area for connection for larger useful vol
27. te base plate must be placed over the rainwater storage tank A formwork plan and reinforcement drawing can be provided on request The parts listed in the Accessories chapter can be retrofitted Pre scored areas On the ends and the back max DN 150 see in illust ration Other points are not allowed without the agreement of the manufacturer Only use the KESSEL saw cap for scoring the openings see Accessories chapter Only use KESSEL seals for ducts for sealing see Accesso ries chapter cupola area D Be ise Q gt O Remark To achieve optimum sealing of the bore hole the clearance between the edge of the bore hole and uneven contour should not be less than 15 mm 15 15 mm mm ik KESSEL 3 Plant description and technical data Dimensioned drawing Leerrohr DN 150 3000 Liter 4500 Liter 6000 Liter 3000 Liter 4500 Liter 6000 Liter ik KESSEL 1785 2300 2300 Erduberdeckung Ten T 90 mm 5 LU E Zulauf DN 100 m 1375 1155 1420 1130 1895 1675 1945 1670 1895 1675 1945 1670 Weight in kg T TEU Aqabase Attachement Fixtures Class A B Class D 1010 1100 75 105 85430 80B D 1010 1100 75 105 85445 80B D 1010 1100 75 105 85460 80B D Base dimension Mean dimension of scored areas Q Rainwater storage tanks Aqabase Komfort 2 Inlet slowdown 3 Overflow siphon
28. tion d leau de pluie Aqabase den folgenden Normen entspricht is in agreement with est en accord avec DIN 1986 100 DIN 1988 4 EN 1717 EN 12056 EN 476 EN 752 2 3 Zur Kennzeichnung der Ubereinstimmung der Produkte ist auf dem Typenschild das Zeichen der Richtlinie 93 68 EWG angebracht The 93 68 EEC code mark should be located on the ID plate on the product Le marquage et indentification du produit figurent sur la plaquette d identification selon les directives 93 68 EWG Lenting den 4 12 2009 A Kessel E Thiemt Vorstand Vorstand Managing Board Managing Board Conseil d administration Conseil d administration ik KESSEL 26 Important contacts Info Separator Type Day Hour Project description Building services supervisor Address Telephone Fax Builder Address Telephone Fax Planner Address Telephone Fax Contracted plumbing company Address Telephone Fax Commissioning no KESSEL System operator owner Address Telephone Fax Other remarks The system operator and those responsible were present during the commissioning of this system Place and Date Signature Builder Unterschrift Anlagenbetreiber d Backwater protection L Septic Systems _ Lifting Stations and pumps _ Inspection Chambers L Drains and shower channels LJ Rainwater Management 2 Separators Systems Grease Separators Oil Fuel Coalescence Separators Starch Separators Sediment
29. trictly followed Backwater occurs when soils that only allow little water to permeate prevent seepage water flowing away Backwater is formed parti cularly after heavy rain or when snow melts ik KESSEL Installation in areas that can be driven over Class D When the tanks are installed in areas that can be driven over Class D a concrete base plate must be placed over the rainwater storage tank A formwork plan and reinfor cement drawing can be provided on request The parts listed in the Accessories chapter can be retro fitted Pre scored areas On the ends and the back max DN 150 see in illustra tion Other points are not allowed without the agreement of the manufacturer Only use the KESSEL saw cap for scoring the openings see Accessories chapter Only use KESSEL seals for ducts for sealing See Ac cessories chapter Remark To achieve optimum sealing of the bore hole the clearance between the edge of the bore hole and uneven contour should not be less than 15 mm 3 Plant description and technical data Dimensioned drawing Leerrohr DN 150 E A i Ablauf DN 100 3000 Liter 1200 1785 1425 1420 1130 110 4500 Liter 1760 2300 1945 1945 1670 150 6000 Liter 1760 2300 1945 1945 1670 150 Weight in kg Aqabase Attachement Fixtures Class A B Class D 3000 Liter 335 835 80 110 85630 80B D 4500 Liter 335 835 80 110 85645 80B D 6000
30. ubmersion pump KTP 300 10 m cable without floating switch made of PP R1 28 740 with backwater flap 10 m cable with floating switch connection can be pivoted R1 28 840 Motor capacity P 300 W Operating voltage 230 V 50 Hz max pumping height 6 5 m max pumping capacity 8 7 mi max submersion depth 10 m Pressure connection R 1 side vertical Suction cage can be removed reduction of the water level to 8 mm possible Mobile or stationary use No tilting no lurching Can be submersed completely ik KESSEL 25 CC I KESSEL EU KONFORMITATSERKLARUNG EC declaration of conformity D claration CE de conformit Nach der Maschinenrichtlinie 98 37 EG der Niederspannungsrichtlinie 73 23 EWG Richtlinie der elektromagnetischen Vertr glichkeit 89 336 EWG und Richtlinie f r Druckgerate 97 23 CEE According to the Machine Guidelines 98 37 EC the Low Voltage Guidelines 73 23 EEC Electromagnetism Guidelines 89 336 EEC and the Pressure System Guidelines 97 23 CEE Selon les directives m caniques 98 37 EG les directives de basse tension 73 23 EWG les directives pour la compatibilit lectromagn tique 89 336EWG et les directives pour appareil pression 97 23 CEE KESSEL AG Bahnhofstra e 31 D 85101 Lenting erklaren wir we declare nous d clarons dass das Produkt that the product que le produit KESSEL Regenwasserspeicher Aqabase KESSEL Rainwater storage tank Aqabase Citerne de r cup ra
31. ume ik KESSEL 3 Plant description and technical data 3 5 KESSEL Rainwater storage tank Aqabase Retention k Condition on delivery scope of supply Tank grey Telescopic height adjustment of attachment piece Cover Class B according to EN 124 made of cast iron lock able surface waterproof with lift out key Secured against unauthorised opening by 3 inner hex bolts Inlet DN 100 with integrated inlet slowdown connection through slip on sleeve Outlet DN 100 with outlet throttling 0 1 I s emergency overflow DN 100 and overflow siphon connection through pointed end Empty conduit connection DN 150 with seal for pipe duct and KG socket plug Instructions for installation operation and maintenance The rainwater storage tank can be used in areas driven over by cars The limits of soil cover in the area that can be walked on are 500 mm lt DSC lt 1500 mm and in the area than can be driven over at 700 mm lt DSC lt 1500 mm The soil cover DSC corresponds to the clearance between the gro und level and the back of the rainwater storage tank The parts listed in the Accessories chapter can be retro fitted Installation in groundwater The maximum water level must not rise above the base di mension of the standard outlet even briefly To guarantee safety from buoyancy the soil cover layer must be at least 700 mm thick The information in chapter 5 Installation and assembly must be s
32. valid installation and user s manual as well as the corresponding norms regulations 2 Wear and tear on a product will not be considered a defect Problems with products resulting from improper installation handling or maintenance will also not be considered a defect Note Only the manufacturer may open sealed components or screw connections Otherwise the warranty may become null and void 01 06 2010 ik KESSEL 8 Accessories Article Order Nr KESSEL single flap backwater valve Staufix with emergency valve made of plastic Flap closes automatically and there is an emergency valve that can be closed by hand Not for wastewater with sewage DN 100 L 355 H 180 25 AxB 205x 155mm DN 125 L 405 H 240 40 AxB 270 x 200 mm DN 150 L 450 H 240 40 AxB 270 x 200 mm DN 200 L 530 H 278 50 Ax B 353 x 248 mm With plastic flap 100 72 100 125 72 125 150 72 150 200 72 200 With stainless steel flap rat protection 100 72 100R 125 72 125R 150 72 150R KESSEL suction fine filter floating 85 050 for suctioning unfiltered rainwater from rainwater storage tanks floating version with floating ball made of PE with suction hose 3 m long standard suction hose and connection and hose fitting filter body with filter made of stainless steel mesh width 0 23 mm all connections 1 inch with backflow protection device Guarantees suctioning of the cleanest water about 15 cm underneath the water
33. y an insect proof aeration and ventilation stack Aeration and ventilation must not be together with other installati ons e Insert the telescopic KESSEL attachment piece into the opening of the rainwater storage tank and move to the i 8 5 RB p i Ill shows 6000 I Tank S required position With the aid of the existing clamping ring it is now possible to fasten the attachment piece in the de sired position alignment with the top ground surface The fine adjustment to the final height is then effected with the adjusting screws A ground slope can be compensa ted for with the continuously height adjustable and up to 5 inclinable attachment piece The attachment piece must then be sufficiently backfilled and compacted For larger installation depths the special KESSEL adap ter part no 917403 installation height 400 mm is to be used f Secure the rainwater storage tank cover against unauthorised opening 20 6 Installation Service and Maintenance The chapter Safety instructions must be heeded Initial operation The rainwater storage tank may only be put into operation when the technical expert of the company that has been commissioned to carry out the installation has certified pro per installation Before the rainwater storage tank is put into operation the rain collecting area the trough the downpipe the drain basic pipe rainwater filter and outlet pipe must be cleaned of forei