Home

User Manual

image

Contents

1. U Line L2 Volts L1 24 VAC U Feedback signal Transformer Attention e Observe polarity on secondary of transformers e Connect all actuator black wires 1 to line of transformer and all red wires 2 to the other leg of the transformer and all white wires 3 together to Y of control signal Incorrect polarity can damage controller or cause an error in operation Before starting the operation all electrical and mechanical functions have to be checked The actuator and the controller must be powered by separate transformer Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 100 Poway CA 92064 www inteccontrols com Printed in Germany User Manual GA P70 024 Page 8 INEC CONTROLS A Wilson Mohr Company 8 Dimensions 2 72 3 69 00 disengage button 3 a oN Do o Nlis oma N ym B Aa S 12 o Q2 23 00 oz 10 00 l inches mm 4 53 gt Anti rotation mounting bracket supplied w actuator 115 00 9 Ordering information GA P70 024 w Plenum rated cable GA P70 024T w Terminal block Note Terminal version actuator comes without a feedback signal adj visual position indicator and angle selector Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change
2. GRUNER GHIN 74 CONTROLS GA P70 024 Direct coupled non spring return actuators 70 in Ib User Manual November 2003 CE LISTED ISO 9001 Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 100 Poway CA 92064 www inteccontrols com Printed in Germany User Manual GA P70 024 Page 3 INEC CONTROLS page 1 Application siiis eeo iaeaea a aaaea AALE A EENAA a a a EAEE aN aKa EAE EEEE 4 2 Safety remarks vecesinis cs ccscschec nated iaae naaar aa AAEE eaaa aa aeae aa aaa EAEE aaaea a EATEN NENE EREA 4 3 installation vcccfictsccncenecacerscasc nadecksseetetatupeieecedinatncnenehtieheecdechesteeavanseduucecstecwatedes Getseecslevancdredestnnd 4 4 Adjustment of the angle of rotation 2 cccccceeeeeeeeeceeeeeeeeeeeeeeeee seen eneeeeeeeesneeeseeeeeneneene 5 5 Adjustment of the rotation direction and of the regulating range for proportional CONTIN iasiccsceteseccnsisecen cease cnetndeenssvasevescunees acess aaa Enan Earann Esa denveanstntecesssenstennsneess 5 6 Wiring configuration ccceccsceestecstxesesscencceteveninetncnenensdeseencecheceecauanseciecccantenstnneanctedheccneenetenrandenn 6 7 Parallel control of two or more actuators ssssssssusssnnnunnnnrnnnnnnnnnnnnnnnununnnnnnnnnnnnnn ennnen nnna 7 8 DiMenSi NS vec cciceccscecs ieecs elec de ioe ces eveeat
3. e ete iua kin tie cectiv akari Ra ra rakd E ori acti hiv seeeeebi ideas kere 8 9 Ordering information si c 20ccci estate iste ne Re eee eed 8 10 SPCC Cath ONS eescis see cececicec dacs cet cecces evszecescceneacaveoae see cts cavanauetes aCA aorako ra ss vsestozecestsasasseeeideeeaes 9 Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 100 Poway CA 92064 www inteccontrols com Printed in Germany User Manual GA P70 024 Page 4 INEC CONTROLS Direct coupled non spring return actuators 70 in lb 1 Application Actuators to be easily installed by direct shaft mounting on air dampers shutters and butterfly valves in ventilation and air conditioning systems Can be controlled by any compatible electric or electronic analog controller DDC PLC control or automation system The actuators should be mounted indoors in a dry envi ronment relatively free from corrosive fumes 2 Safety remarks The actuators are not suitable for use in explosive atmospheric applications All service to the actuators mounting electrical connection retrofitting and repair must be carried out with the power supply disconnected The electrical connection must be done by a trained and competent person consi dering the wiring diagrams local and national regulations Use copper twisted conductors only Provide dis connect and overload
4. n range for proportional control The actuator is adjusted to clockwise direction by the factory gt R To change the direction of rotation turn the adjustment knob 2 to L The actuator is factory set for a 0 to 90 range with a 2 to 10 VDC input signal A smaller rotation range may be selected 3 where 2 to 10 VDC is propor tional to the range The actuator must be switched off during set up Note Terminal version has no feedback signal and no angle selector 3 CONTROLS lt 20 100 Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 100 Poway CA 92064 www inteccontrols com Printed in Germany User Manual GA P70 024 Page 6 INEC CONTROLS 6 Wiring configuration Notes e Actuators are provided with color coded wires e Observe polarity on secondary of transformers All common and signal must be connected in line Incorrect polarity can cause controller damage or operation error e Long wire runs requires a 4 wire configuration connect common for power and control signal at the actuator or close by Greater than a 0 2 V drop must be avoided for any common wire Always use a separate transformer when controller power is full wave rectified e Controller and actuators must have separate transformers for paralleled multi actua
5. ntrols 12700 Stowe Dr Suite 100 Poway CA 92064 Fax 858 578 4633 amp 888 FX INTEC www inteccontrols com Physical Enclosure cover base color protection Mounting position Anti rotation bracket Stacking paralleling Clamp connection to round shaft square shaft Wire connection Wire size Terminal version wire connection Dimensions Weight Manufacturing Listings Approvals Warranty CONTROLS ABS UL 94 5V PA 6 6 Grey and black NEMA 2 NEMA 1 for Terminal version Any position Included w actuator Refer to table Multiple Actuators 5 46 to 5 8 8 to 16 mm O 5 46 to 15 32 8 to 12 mm 3 ft 0 9 m cable color coded plenum rated 18 AWG 0 75 mm Terminal block outside of cover screw type for lead wire min 26 AWG 0 14 mm max 14 AWG 2 5 mm 4 53 x 2 56 x 2 40 in 115 x 65 x 61 mm 1 2 Ibs 0 53 kg ISO 9001 certified CE UL and CSA Five year material and workmanship Two year standard three year conditional Specification subject to change without notice Printed in Germany
6. protection if necessary This actuator may only be operated by 24 VAC VDC The transformer must be sized according to technical data of the actuator see section 10 Electronics and controllers must be powered from a separate transformer when controller power is full wave rectified Otherwise the controller or the actuator may be damaged Always read the controller installation instructions before making any connection 3 Installation Direct mounting with V bolt clamp to the damper shaft diagr 1 and fixing with enclosed anti rotation mounting bracket diagr 2 Shaft 5 46 to 5 8 8 16 mm O 5 46 to 15 32 0O 8 12 mm e Turn the damper until the blades are closed e Disengage the gears by pressing the red button and rotate the clamp until the switching position indication shows 90 e Tighten the nuts on the clamp 4 6 ft lb diagram 1 diagram 2 Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 100 Poway CA 92064 www inteccontrols com Printed in Germany User Manual GA P70 024 rs INTEL 4 Adjustment of the angle of rotation Both end stops are adjusted to 0 and 90 For smal ler rotation angles loosen the screws 1 at the metal end stop adjust the end stops as required and fasten the screws again 5 Adjustment of the rotation direction and rotatio
7. tor application e Provide overload protection for line voltage and disconnect as required GA P70 024 Proportional control U Feedback signal Line L2 9S 2 10 VDC Volts L1 Signal can provide position indication or master slave applications 24 VAC z Terminal version is w o feedback signal Transformer Y Control signal 2 10 VDC or 4 20 mA w 500 Q resistor between com blk and Y control signal wht 4 Terminal version wiring connection 1 com 2 24V 3 control signal Multiple actuators GA P70 024 L R selector built in actuator cover maximum quantities Proportional Select Angle of rotation Stacking torque is additive 4 R CW 0 90 Parallel connection 90 L CW 0 90 2 10 VDC Parallel connection 10 4 20 mA w 500 Q resistor Master slave 10 via U feedback signal Customer Services 858 578 7887 amp 888 GO INTEC Fax 858 578 4633 amp 888 FX INTEC Specification subject to change without notice INTEC Controls 12700 Stowe Dr Suite 100 Poway CA 92064 www inteccontrols com Printed in Germany User Manual GA P70 024 Page 7 INEC CONTROLS 7 Parallel control of two or more actuators Notes e Provide overload protection and disconnect as required e Always use a separate transformer when controller power is full wave e Set reversing switch L R as required GA P70 024 Proportional control Y Control signal
8. without notice INTEC Controls 12700 Stowe Dr Suite 100 Poway CA 92064 www inteccontrols com Printed in Germany User Manual GA P70 024 ooo UMEL 10 Specifications Control Input signal Input impedance Feedback signal Electrical Power supply Over voltage Power consumption Performance Torque Damper size Angle of rotation CCW L and CW R angle Rotation time Power failure Position indicator Synchronization Overload protection Manual override Motor type Noise level Environmental Permissible ambient working temperature storage temperature humidity Customer Services 858 578 7887 amp 888 GO INTEC Proportional 2 10 VDC or 4 20 mA w 500 Q resistor 50 kQ 2 10 VDC Terminal version is w o feedback signal 24 VAC VDC 20 50 60 Hz Up to 40 V max 5 sec 2 5 W 4 5 VA 70 in Ib 8 Nm Up to 18 sq ft 1 6 m 0 95 95 0 selectable adj angle with integral stops L R selector built in actuator cover Angle selector built in actuator cover electronically adj 20 100 Terminal version is w o angle selector 60 to 120 sec 0 90 Stays in last position of operation 0 10 divisions and adj visual indicator Terminal version is w o visual indicator 1 Electronic throughout rotation Built in disengage button DC motor Max 35 dB A 22 F to 122 F 30 C to 50 C 40 F to 176 F 40 C to 80 C 5 95 RH non condensing INTEC Co