Home

Partner P-832-ICON Keypad User Manual

image

Contents

1. from Ready state Arm system Stay access code do not exit premises OR press if enabled Arm system No Entry Delay access code Bypass zones two digit zone number s to exit Disarm system access code Exit premises when system armed OR press if enabled Reset smoke detectors OR press if enabled Program access codes refer to Programming Access Codes in Instruction Manual Send Fire message press and hold for two seconds if enabled Send Auxiliary message press and hold for two seconds if enabled Send Panic message press and hold for two seconds if enabled Set system time and date master code enter current time 24hr format 00 00 23 59 and date month day year as 10 digits hh mm MMDDYY Silence fire alarm Silence intrusion alarm access code Turn auto arm on off
2. master code Turn door chime on off to toggle on or off OR press if enabled Turn on bypassed zones if Stay armed View alarm memory View troubles Troubles indicated by numbers 1 8 on top of keypad display See Viewing Trouble Conditions in Instruction Manual for list of trouble definitions 2 System Lights 5 Emergency Keys 4 Function Buttons 3 Number Pad 1 Display Using the P832 ICON Keypad WARNING Please refer to the System Instruction Manual for information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer I N S T R U C T I O N S
3. 1999 Digital Security Controls Ltd Printed in Canada 29004721 R002 1 Display 2 System Lights Ready Light If the Ready light is ON the system is ready for arming The system cannot be armed unless the Ready light is ON Armed Light If the Armed light is ON the system has been armed successfully Trouble Light If the Trouble light is ON press to view the troubles The keypad will indicate the troubles using numbers 1 8 at the top of the keypad display See Identifying Trouble Conditions in your system s Instruction Manual 3 Number Pad Use the number pad to enter your code and to access system functions To exit a function and return to the Ready state press To select a function press 5 Function Buttons If your installer has enabled them you can use the function buttons to access the stay arm away arm door chime sensor reset and quick exit features Your installer may program other functions for these buttons Press and hold the appropriate button for two seconds Refer to your Instruction Manual for more information on these features 4 Emergency Keys Press both keys for two seconds to send a FIRE message Press both Keys for two seconds to send an AUXILIARY message Press both Keys for two seconds to send a PANIC message IMPORTANT NOTE All Keypads The Fire Auxiliary and Panic keys will NOT function unless programmed by the installer If these keys are in service and the
4. installer has enabled audible feedback holding down the key for two seconds will cause the keypad sounder to beep indicating that the input has been accepted and sent The P832 ICON keypad shows the status of your security system using an LCD style display along with fixed words and numbers This instruction sheet describes the basic features of the keypad For more detailed information on your security system and how to use it please read your system s Instruction Manual Important Note Test system weekly and have any system trouble conditions corrected by your alarm installer Using the P832 ICON Keypad The P832 ICON works similarly to the other keypads described in your system s Instruction Manual For more information on individual functions see your system s Instruction Manual Viewing Open Zones Before you can arm your system all the zones must be closed If some zones are currently open the keypad will display Open and the Ready light will be off To see the numbers of the open zones press Before you try to arm your system go to the open zones and close all doors and windows and make sure no one is present in zones with motion detectors Viewing Zones in Alarm If there is an alarm on your system the keypad will display Alarm and will scroll the numbers of the zones affected System Functions Quick Reference The following chart lists the basic functions of your system and the keys to pres
5. master code enter current time 24hr format 00 00 23 59 and date month day year as 10 digits hh mm MMDDYY Silence fire alarm Silence intrusion alarm access code Turn auto arm on off master code Turn door chime on off to toggle on or off OR press if enabled Turn on bypassed zones if Stay armed View alarm memory View troubles Troubles indicated by numbers 1 8 on top of keypad display See Viewing Trouble Conditions in Instruction Manual for list of trouble definitions 2 System Lights 5 Emergency Keys 4 Function Buttons 3 Number Pad 1 Display Using the P832 ICON Keypad WARNING Please refer to the System Instruction Manual for information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer I N S T R U C T I O N S 1999 Digital Security Controls Ltd Printed in Canada 29004721 R002 1 Display 2 System Lights Ready Light If the Ready light is ON the system is ready for arming The system cannot be armed unless the Ready light is ON Armed Light If the Armed light is ON the system has been armed s
6. s for each function NOTE Some functions may not be available on your system Ask your installer for more information To do this Press this Arm system Away access code leave through entry exit door OR press if enabled Arm system Quick from Ready state Arm system Stay access code do not exit premises OR press if enabled Arm system No Entry Delay access code Bypass zones two digit zone number s to exit Disarm system access code Exit premises when system armed OR press if enabled Reset smoke detectors OR press if enabled Program access codes refer to Programming Access Codes in Instruction Manual Send Fire message press and hold for two seconds if enabled Send Auxiliary message press and hold for two seconds if enabled Send Panic message press and hold for two seconds if enabled Set system time and date
7. s instruction sheet describes the basic features of the keypad For more detailed information on your security system and how to use it please read your system s Instruction Manual Important Note Test system weekly and have any system trouble conditions corrected by your alarm installer Using the P832 ICON Keypad The P832 ICON works similarly to the other keypads described in your system s Instruction Manual For more information on individual functions see your system s Instruction Manual Viewing Open Zones Before you can arm your system all the zones must be closed If some zones are currently open the keypad will display Open and the Ready light will be off To see the numbers of the open zones press Before you try to arm your system go to the open zones and close all doors and windows and make sure no one is present in zones with motion detectors Viewing Zones in Alarm If there is an alarm on your system the keypad will display Alarm and will scroll the numbers of the zones affected System Functions Quick Reference The following chart lists the basic functions of your system and the keys to press for each function NOTE Some functions may not be available on your system Ask your installer for more information To do this Press this Arm system Away access code leave through entry exit door OR press if enabled Arm system Quick
8. uccessfully Trouble Light If the Trouble light is ON press to view the troubles The keypad will indicate the troubles using numbers 1 8 at the top of the keypad display See Identifying Trouble Conditions in your system s Instruction Manual 3 Number Pad Use the number pad to enter your code and to access system functions To exit a function and return to the Ready state press To select a function press 5 Function Buttons If your installer has enabled them you can use the function buttons to access the stay arm away arm door chime sensor reset and quick exit features Your installer may program other functions for these buttons Press and hold the appropriate button for two seconds Refer to your Instruction Manual for more information on these features 4 Emergency Keys Press both keys for two seconds to send a FIRE message Press both Keys for two seconds to send an AUXILIARY message Press both Keys for two seconds to send a PANIC message IMPORTANT NOTE All Keypads The Fire Auxiliary and Panic keys will NOT function unless programmed by the installer If these keys are in service and the installer has enabled audible feedback holding down the key for two seconds will cause the keypad sounder to beep indicating that the input has been accepted and sent The P832 ICON keypad shows the status of your security system using an LCD style display along with fixed words and numbers Thi

Download Pdf Manuals