Home
Ametek DTI-050 Temperature Indicator Data Sheet PDF
Contents
1. ccccseeeeeeeees O 59 0 00385 1 C Minimum immersion depth 30 mm 1 18 in Self heating effect 0 06 C mW 0 108 F mW Response time Meee MOO 1G ets seid tre arind E E N EE 16 seconds Measured in water Electrical connections E 6 neem eee E ee re ee 4 wire shield CONNECCION erranssa E EaR Eis LEMO goldplated Insulation resistance OT CITS Fee 3 Gohm Outer tube AISI 316T Operating conditions Probe connection and cable Max 70 C 158 F Storage temperature ssssssseseeeeeeeenees 20 to 70 C 4 to 158 FORIO ssori O to 90 RH Protection class connectors cccceeeeeees DIN 40050 IP 50 Shipping dimensions STS 102 A probe including carrying case EAA a aca ectensediceasnoocce 220 x 250 x 60 mm 8 7 x 9 8 x 2 4 in Shipping weight including packing STS 102 A probe ach et teciemtanensteceeigatencnceecesaeeedeces 550 g 1 2 Ib 10 www jofra com Order no Description Temperature Indicator DTI050 DTI050 Temperature Indicator Certification DTI050 G NIST traceable certificate standard H Accredited certificate STS reference sensor 102 Pt100 reference probe cable 50 to 155 C 58 to 311 F Diameter of the probe A Overall diameter 4 mm 0 16 in Shape and length 030 Short sensor 30 mm 1 18 in in plastic case Calibration certificate F NPL traceable calibration certificate on sensor H Accredited calibration cert
2. Auto shut off to extend bat tery life user programmable Type Select type of sensor When using an STS refe rence sensor with intel ligence the indicator auto matically finds the sensor and the data Resolution 1 C 0 001 C Maximum resolution depends on the selected sensor type Hold Makes it possible to freeze the results when doing measurement The results are saved in the EEPROM when it is switched off Serial interface RS232 serial interface to communicate with JOFRA CAL calibration software Also used if adjustment of the unit is necessary External power supply MAX MIN Reads the highest and lowest value from last reset Monitor a safety alarm or look for tempera ture spikes in the process Min and max are saved in the EEPROM when it is switched off It is possible to connect the DTI050 to external 9V supply Useful softcase The DT1050 indicator is supplied in a handy softcase as standard The softcase that protects the instrument is a useful part of the instrument The softcase is designed for easy vertical operation so when opening the case there is easy access to all accessories in the pocket A flap on top of the softcase provides access to the temperature sensor The softcase includes a shoulder strap for convenient transportation of the instru ment when climbing ladders etc At the back of the case a handy strap that fits the hand also makes it possible to han
3. Order No Description Temperature Indicator FP Industrial temperature sensors DTI050 DTI050 Temperature Indicator Temperature IS one of the most measured parameters within industry and science A correct measurement is of great impor Calibration certificate tance to the quality of the product as well as to the security G NIST traceable certificate standard and the energy consumption Therefore it is very important to H Accredited certificate choose the right sensor for the actual application Options Based on long standing experience with development produ C Carrying Case max 350 mm straight probe ction and sales of FP industrial temperature sensors AMETEK X No option used has worked out a unique selection system facilitating the work when ordering industrial temperature sensors and at the same DTIOSOGX Sample order number a time ensuring the optimal choice The system can handle several JOFRA DTI050 temperature indicator with million types without sacrificing the clarity Only 51 spec sheets standard NIST traceable calibration certificate and a Sensor Guide now enable the user to design and adapt the sensors which is the optimal choice for his appllication STANDARD DELIVERY Please find more information about FP industrial temperature sensors at www jofra com e DTIO50 indicator Especially for the DTI050 temperature indicator AMETEK can e NIST traceable calibration certificate in ohm and mV offer the followi
4. temperature Wide temperature range DT1I050 200 to 2500 C 328 to 4532 F STS 050 probe 50 to 400 C 58 to 752 F STS 100 probe 150 to 650 C 238 to 1202 F STS 102 probe 45 to 155 C 49 to 311 F Improve your accuracy DTI050 accuracy to 0 005 C 0 009 F DTI050 STS probe accuracy to 0 04 C 0 072 F Intelligent sensor Critical information stored in a memory chip in the intelligent sensor gives easy access to relevant data and avoid mistakes Minimize paperwork RS232 communication special calibration and data storage software are included Fast response time Ensures correct monitoring of the tempera ture stability Specified low drift Maintains a minimum uncertainty budget throughout the period between re calibra tion intervals Wide selection of probes Straight probes 90 angled probes or cable probes offering flexibility in test methods depending on the sensor under test True field calibrator Low temperature coefficient high accuracy in the lab and in the field ISO 9001 Manufacturer Specification Sheet SS CP 2295 US JOF RA DTI050 Digital Temperature Indicator Handheld reference indicator offering traceable temperature measurement AMETEK Calibration Instru ments has broadened the DTI program by introducing the small sized and easy to use reference indicator JOFRA DTI050 Combined with an accurate JOFRA STS temperature reference sensor the DTI050 temp
5. 0 055 C 0 099 F 1 3 50 to 320 C 58 to 608 F 0 050 C 0 090 F 1 2 0 060 C 0 108 F 1 3 50 to 400 C 58 to 752 F 0 065 C 0 117 F 1 2 0 080 C 0 144 F 1 9 50 to 650 C 58 to 1202 F 0 090 C 0 162 F 1 2 0 100 C 0 180 F 1 3 STS 102 cable sensor see more at page 9 45 to 155 C 49 to 311 F 0 040 C 0 072 F 1 2 0 070 C 0 126 F 1 3 All sensors are supplied with an accredited or traceable certifi cate from a National Accredited Laboratory stating the sensor coefficients Note 1 Specified at 95 confidence interval k 2 over full range including calibration uncertainty excluding 1 LSD Least Significant Digit Note 2 Excl sensor drift please see long term stability at page 5 Note 3 Incl sensor drift please see long term stability at page 5 after 100 hours at max temperature Specification Sheet SS CP 2295 US CONO050 configuration software for special sensor coefficients The JOFRA DTI050 uses intel ligent detection technology for sensors This means that it is able to automatically read calibration data and sensor type from a memory chip placed in the sensor This chip is standard in the STS 050 series and is optional on the STS 100 series The intelligent sensor reading makes it possible to change the sensors used without re pro gramming your DTIO50 When an intelligent sensor is connected all information about the
6. wD gt Shape and length 250 Straight probe 250 mm 9 8 in in alu case 350 Straight probe 350 mm 13 8 in in alu case 500 Straight probe 500 mm 19 7 in in alu case 901 90 angled probe 207 mm 8 1 in in plastic case Calibration certificate F NPL traceable calibration certificate on sensor H Accredited calibration certificate on sensor standard FS NPL traceable system calibration certificate HS Accredited system calibration certificate Options C System carrying case max 350 mm probe X No option used DTI050G100A250HXX Sample order number JOFRA DTI050 temperature indicator with NIST traceable calibration certificate and 4 mm STS 100 Reference sensor Straight 250 mm with accredited calibration certificate and 2 m cable REDEL connector for DTI050 JOFRA STS 100 A B Order no Description Base model number Pt100 reference probe solid 150 to 650 C 238 to 1207 F STS100 Diameter of the probe A Overall diameter 4 mm 0 16 in B Overall diameter 6 35 mm 0 25 in Shape and length 250 Straight probe 250 mm 9 8 in in alu case 350 Straight probe 350 mm 13 8 in in alu case 500 Straight probe 500 mm 19 7 in in alu case 901 90 angled probe 207 mm 8 1 in in plastic case Cable length and termination Cable 0 5 m 1 6 ft LEMO connector Cable 2 m 6 6 ft LEMO connector Cable 2 m 6 6 ft Banana plug connectors Cable 2 m 6 6 ft REDEL connector for DTI
7. 100 A B series has a relatively small diameter This leaves optimum space for sensors under test in the dry block and ensures a fast response time A fast reacting sensor will optimize the measurement information In addition to straight probes in 4 mm and 1 4 in AMETEK also offers a 90 angled version specifically developed for use with dry block temperature calibrators This probe allows the user to have both the sensor under test and the reference probe in the thermowell at the same time even if the sensors have a connection or a transmitter head Reduced hysteresis and drift The main reason for drift within a sensor assembly is im purities within the element especially at temperatures above 350 C 660 F All internal parts must be cleaned thoroughly The assembly of the components is performed in a clean room These precautions ensure minimum contamination of the ele ment during use and provide the user with the best possible performance Ageing annealing Once the probes are assembled they are subjected to a long approval process This includes mechanical stress reduction of the entire assembly as well as ageing the sensor element itself The purpose of ageing the sensor is to remove the initial drift The procedure involves heating the sensor up to maximum and holding it for 1 hour before cooling down This process is repeated over a period of several days The resistance is then measured at 0 C 32 F and recorded The
8. 2380 See the above mentioned specification sheets and further information about the JOFRA instruments at www jofra com Specification Sheet SS CP 2295 US SPECIFICATIONS STS 100 A B Temperature range All probes sestencacemcneceduesicsnatioianass 150 to 650 C 238 to 1202 F Accuracy Hysteresis 0 C 32 F 0 01 C 0 02 F Long term stability 2 0 C 32 F typ 0 014 C 0 025 F Repeatability 1 0 002 C 0 0036 F Note 1 When used in the range 80 to 650 C 112 to 1202 F Note 2 When exposed to 650 C 1202 F for 100 h Stability will depend on actual use of the sensor Sensing element e E E E E E E ce eee seo Pt100 Nominal resistance 0 C 32 F ccccccccsseseeeeeeeeeeeeeees 100 Q LE NOU ee use det se ccecaetutneneesncaerananeaandeac 40 mm 1 6 in Temperature Coefficient ccccceeeeeee eee OL 59 0 00385 1 C Minimum immersion depth STS 100 A 4 mm 0 16 in ccceeeeeeeeee 100 mm 3 9 in STS 100 B 6 35 mm 0 25 in cctcssesncsccudenceconss 110 mm 4 3 in Self heating effect 0 06 C mW 0 108 F mW Response time STS 100 A 4 mm 0 16 In 50 o ra 8 seconds STS 100 A 4 mm 0 16 in Tog 9076 sxcscsaccnseaniat 26 seconds STS 100 B 6 35 mm 0 25 in Tos 50 18 seconds STS 100 B 6 35 mm 0 25 in T QO 00 44 seconds Liquid in motion v 0 4m s Electrical connections Cable o oo ceccccccccccccceccccecuccc
9. e JOFRA STS 102 A probe e Plastic carrying case with foam insert e Accredited certificate points 45 20 0 50 100 and 155 C e User manual e Calibration tube N COMPATIBLE JOFRA INSTRUMENTS The JOFRA STS 100 probes can be used with the following JOFRA instruments JOFRA DTI 1000 spec sheet no SS CP 2290 JOFRA DTI050 spec sheet no SS CP 2295 JOFRA ATC series spec sheet no SS CP 2285 JOFRA ASC300 spec sheet no SS CP 2350 JOFRA AMC900 spec sheet no SS CP 2380 See the above mentioned specification sheets and further information about the JOFRA instruments at www jofra com See specifications and ordering information at the next page page 10 SPECIFICATIONS STS 102 A Specification Sheet SS CP 2295 US JOFRA DTI050 AND STS 102 A Temperature range All probes ccccecseseeeeseseeeeeeeeeees 50 to 155 C 58 to 311 F Accuracy Hysteresis 0 C 32 F wscssdecccnccaciinacctioastadeates 0 01 C 0 018 F Long term stability 1 0 C 32 F typ 0 025 C 0 045 F Repeatability ccccccetidcectcet coats hasecencbenedseeumeiids 0 002 C 0 0036 F Note 1 When exposed to 155 C 311 F for 200 hours stability will depend on actual use of the sensor Sensing element WS oats E E E PTE E E eet Pt100 Nominal resistance 0 C 32 F ccccccsssseeeeeeeeeeseeeeeees 100 STAG ON ep ceitapesecncesateindeaeaewaedenspoasvendeecceesateneeoei 30 mm 1 18 in Temperature coefficient
10. probe Carton case with foam insert e Straight probes Carton case with foam insert e User manual COMPATIBLE JOFRA INSTRUMENTS The JOFRA STS 050 probes can be used with the following JOFRA instruments JOFRA DTI050 spec sheet no SS CP 2295 See the above mentioned specification sheets and further information about the JOFRA instruments at www jofra com Specification Sheet SS CP 2295 US SPECIFICATIONS STS 050 A B Temperature range All probes eee 50 to 400 C 58 to 752 F Accuracy Hysteresis 0 C 32 F 0 01 C 0 02 F Long term stability 2 0 C 32 F typ 0 014 C 0 025 F Repeatability 1 0 005 C 0 009 F 1 when used in the range 50 to 400 C 58 to 752 F 2 when exposed to 400 C 752 F for 100 h Stability will depend on actual use of the sensor Sensing element e E E A E E E E T Pt100 Nominal resistance 0 C 32 F ccccccccsssseeeeeeeeeeeeeees 100 Q EST Saseqaveneceascenenececosszencunnes ssanconteoeceeenceticeedtens 22 mm 0 9 in Temperature coefficient ccccceeeeeeees OL 59 0 00385 1 C Minimum immersion depth STS 050 A 4 mm 0 16 in 0 eeeeceeceeeeeeeees 60 mm 2 36 in STS 050 B 6 35 mm 7 0 25 in n 90 mm 3 54 in Self heating effect 0 04 C mW 0 07 F mW Response time STS 050 A 4 mm 0 16 M Tye S07 ssiri 7 seconds 0 STS 050 A 4 mm 0 16 in Tog 90 sesesziccesnscacne 17 seconds STS 050 B 6 35
11. sensor is again heated up to maximum and this time the temperature is held constant for 100 hours Finally the output from the sensor is again measured at 0 C 32 F and recorded The difference between the first and the second measurement is recorded The difference between these two measurements is our verification of the stability qualities of the sensor To be accepted for final calibration and certification the probe must meet our minimum tolerance Specification Sheet SS CP 2295 US Reduced isolation resistance error Electrical isolation resistance parasite resistance error when measured at the highest operating temperature should be as high as possible A low isolation resistance would cause the output signal to be incorrect in relation to the temperature JOFRA STS 050 A B and STS 100 A B series probes meet the IEC 751 requirements of isolation resistance by several hundred percent The final quality certificate check Upon completion of every certificate after final calibration of the probe examination and approval cycles are performed according to our established procedures The critical verification is to ensure that the difference between the initial and the final 0 C 32 F measurement on the certificate meets our minimum tolerance These requirements are based on a vast amount of data which has been evaluated statistically This value indicates if the probe has a sufficient long term stability AMETEK al
12. specifications specified at ambient temperature c008 23 C 5 C 73 F 49 F Outside ambient 23 C 5 C ce eceseeeeeeees 0 001 rdg C Outside ambient 73 F 9 F eens 0 0028 rdg F CJ compensation 18 to 28 C 64 to 83 F 0 2 C 0 36 F CJC outside ADOVE c ccccceeeeseeeeeeees 0 05 C C 0 05 F F Power supply IVINS geste aaecnase8eesnecees E 9 VDC 200 mA Battery eecect pec eesestiodctigetenseceutrcossetdieebsatseeteoe 1 x 9 VDC Alkaline Battery life szeesesec pices teat sassctcnosceese ree nenceeee Minimum 10 hours Low battery INGICATOS cccccccesceeceseeeseseeeceseeeneaees at 6 VDC AUO OM ooer tease ceaecneces 1 30 minutes Display EE E E NE E Graphical display Display resolution css ec ctincaucsscudanicntsnccuatenbansivelenwdunensten 5 digits Display update es denece scxuvanencntuavestudseeratecusibaseedt twice per second RS232 communication interface CONNECCION erry e E ances 3 pin JACK Communication rate cee eeseeeeeeeeeeeeeeeeeeees 9600 baud ASCII Instrument dimensions Indicator L x W x H 188 x 84 x 52 mm 7 4 x 3 3 x 2 1 in Indicator weight including battery 0 400 g 14 1 oz Shipping dimensions Indicator L x W x H 250 x 160 x 100 mm 9 8 x 6 3 x 3 9 in Indicator weight including battery 0 1 1 kg 2 4 Ib Specification Sheet SS CP 2295 US ORDERING INFORMATION DTIO50 ACCESSORIES
13. traceable system calibration certificate Accredited system calibration certificate C X Options System carrying case max 350 mm straight probe No option used DTI050G050A250FX Order no STS050 Sample order number JOFRA DTI050 temperature indicator with NIST traceable calibration certificate and 4 mm STS 050 Reference sensor Straight 250 mm with NPL traceable calibration certificate and 2 m cable REDEL connector for DTI050 Description Base model number Pt100 reference probe solid with handle 50 to 400 C 58 to 752 F Diameter of the probe Overall diameter 4 mm 0 16 in Overall diameter 6 35 mm 0 25 in 250 350 500 901 Shape and length Straight probe 250 mm 9 8 in delivered in carton Straight probe 350 mm 13 8 in delivered in carton Straight probe 500 mm 19 7 in delivered in carton 90 angled probe 207 mm 8 1 in delivered in carton Cable length and termination D Cable 2 m 6 6 ft REDEL connector for DTI050 Calibration certificate H Accredited calibration certificate F NPL traceable calibration certificate standard STS050 A 250 D F AMETEK CALIBRATION INSTRUMENTS Headquarter Sample order number 4 mm STS 050 Reference probe Straight 250 mm Cable length 2 m 6 6 ft with REDEL connector for DTI050 and NPL trace able calibration certificate commercial and a technological point of view AMETEK Denmark A S Sales Europe and the Mid
14. 050 oooO Calibration certificate H Accredited calibration certificate Standard F NPL traceable calibration certificate No certificate Annealed only Useless without calibration certificate coefficients STS100 A 901 DH Sample order number 4 mm STS 100 Reference sensor angled 90 Cable length 0 5 m 1 6 ft with REDEL connector for DTI050 and accredited calibration certificate Specification Sheet SS CP 2295 US JOFRA STS 102 A JOFRA has also designed a special cable type reference sensor the STS 102 A Due to the small size and flexible connection the design permits positioning of the sensor throughout the depth E of the well in a dry block eg under a sanitary flange The reference sensor must be placed at the same level and in parallel with the sensor under test as indicated in the illustration to the right The illustration shows calibration of a sanitary sensor The sensor is in contact with the insert Below you see the custom insert and STS 102 A reference sensor placed in a JOFRA ATC 156 B dry block calibrator On the right the sanitary sensor has been fitted into the insert and is ready for calibration Note that the design makes room for the reference sensor cable To learn more about the possibilities with the JOFRA STS 102 A reference sensor see accessory sheet AS CP 2201 available at www jofra com or from your local distributor STANDARD DELIVERY
15. 2 1800 012 021 100 a0 148 22 ota 021 20 150 22 ace ort 020 50 ol s02 1400 019 028 Treo i200 1400 ers oas 027 K 200 aol sea a oi 056 ao 25 148 a 0 16 028 25 tao 1a e oa 025 20 i000 248 tase 0 18 0 98 ooo 1372 ese 2502 ozs 0 41 100 800 148 nar o24 0 48 Teo 900 sare ves oma 025 IN 200 o f a oas 0 87 oo f o a e a ozs 0 42 25 o a e oo 0 87 20 410 e ro 019 0 94 Tato nol vo a 020 0 857 mR of 250 a2 a oe 1 78 260 400 asa 752 oss 1 00 400 i000 752 iss oss 0 96 F000 er tes2 sors 0 49 0 89 S _o 250 4 oa 1 70 i000 asa tase oa 1 12 tooo 1400 tes2 2552 0 50 0 89 1400 1767 asse sets 057 1 08 so of 200 se o2t 098 of tao a2 aaa ota 024 veo 400 248 752 os 0 28 ju 200 0 see se ose 0 94 of e00f a0 av o 25 0 45 ep 0 200 a0 ase o4 072 200 600 soa i112 os 054 Too 800 mme 1472 oas 0 68 o f eof reo 1472 012 oa 0 70 TT reo 2000 212 seae 0 56 1 01 T2000 2500 s6s2 4590 070 1 40 xe 200 o sea 148 o21 098 100 300 148 572 0 10 028 soo 800 sve aare 019 0 94 Specification Sheet SS CP 2295 US FURTHER SPECIFICATIONS Environmental conditions Operating temperature 08 10 to 50 C 14 to 122 F Storage temperature 20 to 60 C 4 to 140 F Atmospheric MUMIOUIY serocsueetinaterccacenssticeredanchatemenditeavenns O to 90 All
16. 30 0 035 752 1166 0 047 630 0 057 0 102 0 011 0 021 80 0 027 poof oof sef 212 0 019 0 085 po oof sof 212 572 0 029 0 051 pT oof of 572 752 0 034 0 062 po 400 eof 72 1166 0 046 0 082 po ao of sof 112 0 012 0 024 po S o of f 32 0 015 0 027 poof iof 82 212 0 019 0 035 po oof f 212 500 0 028 0 050 po 260 sooj 500 572 0 029 0 051 po sooj of 572 752 0 034 0 062 pT 400 eof 752 1472 0 047 0 085 po o of sof 112 0 017 0 030 po o of f 32 0 020 0 086 o of iof 32 212 0 025 0 044 po t00f 260 212 500 0 033 0 060 pT 260 soo soo 572 0 034 0 061 0 072 1472 0 053 0 032 0 036 30 4 400 6 8 32 572 752 E ofj 10 0 025 100 212 72 752 72 752 00 300 00 400 30 630 00 00 300 00 00 30 630 00 00 300 00 00 30 630 00 PT3926 100 ohm 1472 0 053 0 096 PT385 2000hm 200 80 328 112 0 032 0 057 0 of 12 32 0 036 0 068 poof iof sef 212 0 041 0 074 pot woof 260 212 500 0 045 0 081 20 soo sooj 572 0 053 0 095 pT sooj of 572 752 0 057 0 102 pT 4o eof 72 1166 0 076 0 138 PT385 400ohm_ 200 8o 328 112 0 019 0 035 po o o of f 32 0 030 0 054 poof oof sef 212 0 034 0 061 p10 oof 212 572 0 039 0 069 po 00400 572 752 0 044 0 079 pT 4o eof 752 1166 0 056 0 101 Specification Sheet SS CP 2295 US 4 wire RTD Type 12 months Te
17. cecucccucucaeaucueauaucucaeaueas 4 wire shield SOMMOC LON soriire sanninna e A a LEMO goldplated Insulation resistance CPS LETTA a E E E EEN EAA E ene ae 100 Gohm O G50 O7 1202F en S 70 Mohm Outer tube Inconel 600 Operating conditions Probe connection and cable Max 70 C 158 F Storage temperature ccceee 20 to 70 C 4 to 158 F Humidity lt 2 2dcexeckexceadacccundneveiicbacenseqantesdaccsedeassaecneds O to 90 RH Protection class connectors ccseeeeeees DIN 40050 IP 50 Shipping dimensions including carrying case Straight probes LX W X H eccetrctcty ccasedanracerone nes aseaeeuayenoreccdate AEE E LEETE 750 x 140 x 140 mm 29 5 x 5 5 x 5 5 in 90 angled probe L x W x H sesercadsiemncaiec speeedccaseeenaaliensaneencgunautes E PEE E EEEE A 220 x 250 x 60 mm 8 7 x 9 8 x 2 4 in Shipping weight including packing Straight DIODES wsoccesncticstarciueessudinsencesmnsycattauseiiedenits 1 9 kg 4 2 Ib DO angled PrODE isi cceeccssenceedernstancatessctensesmdencessbacets 550 g 1 2 Ib JOFRA DTI050 AND STS 100 A B Order No Description Temperature indicator DT1I050 DTI050 Temperature Indicator Certification DTI050 G NIST traceable certificate standard H Accredited certificate STS reference sensor 100 Pt100 reference probe solid 150 to 650 C 238 to 1207 F Diameter of the probe Overall diameter 4 mm 0 16 in Overall diameter 6 35 mm 0 25 in
18. dle East Gydevang 32 34 3450 Aller d Denmark Tel 45 4816 8000 ametek ametek dk www ametekcalibration com www jofra com Information within this document is subject to change without notice 2005 by AMETEK Inc www ametek com All rights reserved Pub code SS CP 2295 US Issue 0609 12 www jofra com AMETEK Calibration Instruments offers a complete range of calibration equipment for temperature pressure and signal including calibration software JOFRA Temperature Calibrators Portable precision thermometer Dry block and liquid bath calibrators 4 series with more than 20 models featuring speed portability accuracy and advanced documenting functions with JOFRACAL temperature calibration software JOFRA Pressure Calibrators Convenient electronic systems ranging from 1 to 700 bar 25 inHg to 10 000 psi multiple choices of pressure ranges pumps and accuracies fully temperature compensated for problem free and accurate field use JOFRA Signal Calibrators Process signal measurement and simulation for easy control loop calibration and measurement tasks from handheld field instruments for multi or single signals to laboratory reference level bench top instruments JOFRA JF Marine Calibrators A complete range of calibration equipment for temperature pressure and signal approved for marine use FP Temperature Sensors A complete range of temperature sensors for industrial and ma
19. erature reference indi cator is the perfect reference thermometer PRODUCT DESCRIPTION The JOFRA DTI050 with an JOFRA STS temperature reference sensor is a fully traceable thermometer recommended as the reference instrument to verify true temperature in any type of temperature calibrator liquid bath or dry block calibrator Use the JOFRA DTI050 and the STS probes as your working temperature reference in any calibration application or use the set up directly for critical measurements in the process The superior specifications combined with a long history of reliability and low drift make the JOFRA DTI050 and the JOFRA STS probes the perfect choice The graphical display makes it is easy to recognize the status of the instru ment and take readings The DTI050 also handles signals from 4 wire RTD s TC s and ther mistors AMETEK CALIBRATION INSTRUMENTS Specification Sheet SS CP 2295 US JOFRA DTIO50 INDICATOR Graphical display Intelligent probe reading Input Large digits display the Capable of reading calibration data and other 1 input channel with 6 pin temperature info lines show information from the memory of the sensor REDEL connector current status and mode standard when using the STS 050 sensors and the small digits show the and optional on the STS 100 sensors details of the sensor Indicator for low battery Running low on battery an icon in the display clearly shows this ON OFF
20. g the instrument on a pipe ladder or the like while performing the calibration test or service task JOFRA STS 050 reference sensors JOFRA STS Superior Temperature reference sensors are based on more than 50 years of industrial temperature sensor manu facturing experience The main requirement of a reference probe is stability The less the probe drifts the lower the measurement uncertainty All JOFRA Superior Temperature Standard probes are economical and offer fast response times low immersion depths compact physical sizes and specified low drift rates even at high temperatures These are all important considera tions when selecting a reference sensor Especially for the DTI050 reference indicator AMETEK has developed a specific series of reference sensors the JOFRA STS 050 Superior Temperature reference sensor which are built to last JOFRA STS reference sensors and system accuracy To get an ideal reference system JOFRA offers a range of reference sensors for the JOFRA DTI050 as it is also possible to use the JOFRA DTI050 with JOFRA STS 100 and JOFRA STS 102 reference sensors System accuracy STS 050 probe with handle see more at page 11 50 to 250 C 58 to 482 F 0 040 C 0 072 F 1 2 0 060 C 0 108 F 1 9 0 065 C 0 117 F 1 2 0 090 C 0 162 F 1 9 50 to 400 C 58 to 752 F STS 100 probe see more at page 8 50 to 250 C 58 to 482 F 0 040 C 0 072 F 1 2
21. ificate on sensor standard FS NPL traceable system calibration certificate HS Accredited system calibration certificate Options C System carrying case max 350 mm probe X No option used DTI050G102A030HXX Sample order number JOFRA DTI050 temperature indicator with NIST traceable calibration certificate and 4 mm STS 100 short 30 mm reference sensor with accredited calibration certificate and 1 m cable REDEL connector for DTI050 JOFRA STS 102 A Order no Description Base model number Pt100 reference probe cable 50 to 155 C 58 to 311 F STS102 Diameter of the probe A Overall diameter 4 mm 0 16 in Shape and length 030 Short sensor 30 mm 1 18 in in a plastic case Cable length and termination S Cable 1 m 3 3 ft Integrated Teflon cable LEMO connector D Cable 1 m 3 3 ft REDEL connector for DTI050 Calibration certificate H Accredited calibration certificate standard F NPL traceable calibration certificate No certificate Annealed only Useless without calibration certificate co efficients STS102 A 030 DH Sample order number 4mm STS 102 short 30 mm reference sensor Cable length 1 m 3 3 ft with REDEL connector for DTI050 and accredited calibration certificate JOFRA STS 050 A B STANDARD DELIVERY e JOFRA STS 050 A B probe with handle e Cable according to order number e Traceable certificate points 45 20 0 100 250 and 400 C e 90 angled
22. mm 0 25 in Tys 50 0 11 seconds STS 050 B 6 35 mm 0 25 in Tyg 9070 30 seconds Liquid in motion v 0 4m s Electrical connections AIS ces E rE 4 wire CONNEC CHON essea e REDEL goldplated Insulation resistance O29 C73 F eene et e ENEE 100 Gohm O 400 C7 792 F eenia ee ETA 70 Mohm Outer tube AISI 316 Operating conditions Probe connection and cable Max 70 C 158 F Storage temperature ccccccce 20 to 70 C 4 to 158 F IUIICILY sasascereriscevannertepancivannenasssossnctmmeeninsssucmeoncenes O to 90 RH Protection CIASS cccccccceseceseeeeeeeseeeeeeesaeeass DIN 40050 IP 50 See ordering information at the next page page 12 www jofra com 11 Order No DTI050 Description Temperature Indicator DTI050 Temperature Indicator Certification NIST traceable certificate standard Accredited certificate STS reference sensor Pt100 reference probe solid with handle 50 to 400 C 58 to 752 F Diameter of the probe Overall diameter 4 mm 0 16 in Overall diameter 6 35 mm 0 25 in 250 350 500 901 Shape and length Straight probe 250 mm 9 8 in Straight probe 350 mm 13 8 in Straight probe 500 mm 19 7 in 90 angled probe 207 mm 8 1 in only version B with 06 35 mm FS HS Calibration certificate NPL traceable calibration certificate on sensor standard Accredited calibration certificate on sensor NPL
23. mperature range accuracy co J F e From To From To 0 030 80 0 036 oj 100 32 212 0 025 0 045 100 PT385 500 ohm Oo 32 l 100 0 033 0 060 0 035 0 062 0 041 0 074 32 60 00 2 3 4 6 PT385 1000 ohm ao Mo 0 012 0 021 0 015 0 028 32 212 0 020 0 037 100 2 0 028 0 050 S wj ao0 e 750 oo 0051 OOOO O 1165 0007 oes maa eof 200 ia soo ooa 00r moos eo mo 7e sal ara 002s ECA j oj oie efons oos Fo co e a acco oor ES Ta a00 500 srel ooa ose Tso ao0 e 750 0080 oor a s00 752 168 0047 oes 0 004 rg 0 002 ohm Thermocouple Range Accuracy TC mV read 10 000 mV 75 000 mV 0 005 rdg 5yV Thermocouple Range Accuracy 18 0 64F 28 C 8 F 02 C 0 36 F 0 05 C C CJC outside above 0 025 0 033 0 035 0 041 0 095 0 012 0 015 0 028 60 00 00 30 60 00 Ohm read low Ohm read high Ohm read thermistor kohm Ohm read thermistor kohm 0 05 F F 12 months TC Type Temperature range accuracy co F lt tet ee ooo 1550 1892 2822 oss 1 18 isso 1820 2822 s808 o e7 1 21 fe of 150 32 s oas 045 of 050 sof i202 0o24 0 48 Tso i000 1202 tase 026 0 47 tooo 1800 1882 2272 047 0 85 TF e00 esis sare aon ot 1 46 250 aol me m oar 0 84 of a e a 0 10 0 19 ooo f f o af eee os 020 Taso eso 602 1202 ooo 0 17 TF sso i000 120
24. ng standard FP industrial temperature sensors e Softcase and shoulder strap without certificate and intelligent connector e User manual 125709 Universal sensor with Pt100 and handle e 9V battery 150 mm 3 mm 50 to 250 C e RS232 cable a 125710 Aijir room sensor with Pt100 and handle e JOFRACAL calibration software 100 mm 6 mm 50 to 250 C fi i f CON050 configuration software 125711 Needle sensor with Pt100 and cross grip in stainless steel 100 mm O03 mm 50 to 250 C 125712 Needle sensor with Pt100 and handle Minimum hardware requirements 100 mm 3 mm 50 to 250 C e INTEL 486 processor l 125713 Universal sensor with TC K and handle TM PENTIUM 800 MHz recommended 150 mm 01 5 mm max 850 C e 32 MB RAM 64 MB recommended Specifications JOFRACAL and CONO50 software e 80 MB free disk space on hard disk prior to installation 125714 Universal sensor with TC K ang handle e Standard VGA 800 x 600 16 colors compatible screen 150 mm 3 mm max 1000 C 1024 x 786 256 colors recommended 125715 Air room sensor with TC K and handle e CD ROM drive for installation of the program 100 mm 6 mm max 250 C e 1 free RS232 serial port 125716 Needle sensor with TC K and cross grip in stainless steel 100 mm O03 mm max 400 C Carrying case Optional 125812 125717 Needle sensor with TC K and handle A complete ready to use system may be delivered in a practical 100 mm 3 mm max 400 C alumi
25. nu driven and easy to use with a complete software controlled calibration procedure which saves time This software allows the user to customize his or her calibration routines The software is easy to use so you do not have to be a programmer to configure your own calibration procedures The software features prompts menus and help functions that guide you through the configuration process Once all calibrations are completed the JOFRACAL calibra tion software can be used for post processing and printing of certificates The calibration data collected may be stored in the personal computer for later recall or analysis The JOFRACAL temperature calibration software is standard for the DTI050 but may also be downloaded from our web page www jofra com Please see more about JOFRACAL calibration software in specification sheet SS CP 2510 which can also be found at www jofra com P 4 wire RTD Type 12 months Temperature range accuracy c F e From To From Tof 0 102 80 0 113 o 100 32 212 0 067 0 121 0 081 0 146 7 PT385 10 ohm 3 300 4oo 572 752 0 088 0 158 400 6so 752 1166 0 103 0 185 630 800 1166 1166 1472 0 117 0 210 0 030 0 048 0 045 212 0 064 5 0 074 PT385 50 ohm 0 017 0 027 100 3 400 572 630 752 1166 0 053 0 095 8 0 063 0 114 0 012 0 021 80 100 0 020 0 036 3 0 054 0 063 0 084 300 630 200 PT385 100 ohm 200 0 0
26. num carrying case which can hold the DTI050 and all 125708 Reference sensor with TC N and intelligent connector standard accessories as well as a STS reference sensor 500 mm 04 5 mm max 1205 C Max 350 mm STS 050 reference sensor 125814 Reference sensor with TC N intelligent connector and accredited certificate 500 mm 04 5 mm max 1205 C If any special industrial temperature sensors are required AMETEK is pleased to help with a solution DTI050 power supply accessories 124717 1x 9V rechargeable battery 124718 Charger for 124717 battery 115 230 VAC 124720 Mains adapter 9VDC 200mA 230VAC 115VAC DT1I050 connection accessories 125702 Connector for RTD sensors without intelligence 125703 Connector for RTD sensors with intelligence 125759 Connector for TC sensors without intelligence 125704 Connector for TC sensors with intelligence 125522 2 m adaptor cable to LEMO connector with intel ligence for use with STS 100 and STS 102 sensors 125521 2 m adaptor cable to Banana connectors with intelligence 125523 2 m adaptor cable to mini TC connector with intelligence JOFRA STS Series Quality defined It is not easy to make a good quality reference sensor The main requirement of a reference probe is stability This means minimal drift as a function of operating time at the actual tem perature The less the probe drifts the lower the measurement uncertainty Small diameter fast response The STS 050 A B and STS
27. probe such as serial number calibration data and coefficients are read by DTI050 All information can be shown on the display in the config menu for verification Recalling existing data eliminates errors as a result of programming sensor data For updating the information stored in the sensor DTI050 is supplied with the CONO50 configuration software that allows you to edit all information stored in the probe This includes CVD or ITS90 coefficients for RTD s Steinhart Hart coefficients for Thermistors and a second order deviation function for TC sensors Simplified temperature calibration documentation The DTI050 features an RS232 serial data communication interface This allows the instrument to be serially connected to a personal computer for data storage and reporting The JOFRACAL calibration software supports automatic calibration of all JOFRA temperature dry block calibra tors via RS232 serial data interface including the JOFRA DT1050 digital thermometer the JOFRA DTI 1000 digital ther mometer and the JOFRA ASM Multi scanner For semi automatic calibrations the software also supports liquid baths ice points or other dry block heating and cooling sources Using the software s SCENARIO function allows for combining instruments in virtually any configuration including using the DTI050 either as a temperature reference or as an input module for the sensor under test JOFRACAL calibration software is me
28. rine use because calibration is a matter of confidence AMETEK Calibration Instruments is one of the world s leading manufacturers and developers of calibration instruments for temperature pressure and process signals as well as for temperature sensors both from a Sales offices AMETEK T amp CI Americas Sales The Americas Tel 1 518 689 0222 e jofra info ametek com AMETEK Singapore Pte Ltd Sales Asia Tel 65 6 484 2388 aspl ametek com sg AMETEK Inc Beijing Rep Office Sales China only Tel 86 10 8526 2111 jofra ametek com cn AMETEK GmbH Sales Germany only Tel 49 2159 91360 info ametek de AMETEK Lloyd Instruments Sales UK only Tel 44 0 1489 486 404 e jofra ametek co uk
29. so checks that the linearization coefficients have values that correlate to an acceptable curve sequence in accor dance with our requirements Certification The final documentation on the probe is the calibration certi ficate The JOFRA STS probes can be delivered with either an accredited certificate or a traceable certificate In some cases the customer may prefer to calibrate the probe It is then possible to purchase the probe without any certifica tion JOFRA STS 100 A B A er A B 350 13 78 500 19 69 4 0 16 6 35 0 25 165 6 50 6 35 0 25 42 1 65 12 0 47 134 5 28 0 24 1378 19 69 0416 0 25 6 50 4 0 25 165 047 528 0 24 STANDARD DELIVERY e STS 100 A B probe e Cable according to order number e Accredited certificate points 45 20 0 50 100 200 320 450 and 650 C e 90 angled probe Plastic carrying case with foam insert e Straight probes Aluminium case with foam insert e User manual ACCESSORIES 65 PT100 LL CABLE Cable 2 m 6 6 ft LEMO to LEMO 65 PT100 LB CABLE Cable 2 m 6 6 ft LEMO to banana 122801 Cable 0 5 m 1 6 ft LEMO to LEMO COMPATIBLE JOFRA INSTRUMENTS The JOFRA STS 100 probes can be used with the following JOFRA instruments JOFRA DTI 1000 spec sheet no SS CP 2290 JOFRA DTI050 spec sheet no SS CP 2295 JOFRA ATC series spec sheet no SS CP 2285 JOFRA ASC300 spec sheet no SS CP 2350 JOFRA AMC900 spec sheet no SS CP
Download Pdf Manuals