Home

Weight indicator

image

Contents

1. C This command is sent to the indicator to toggle among the configured units 8 The Additional Features 8 1 The operation description for PA8101A 8 1 1 Function key change the Ilb kg key to UNITS key 8 1 2 Annunciation see in Fig 1 GROSS Indicates that the indicator is displaying gross weight NET Indicates that the indicator is displaying net weight ZERO Indicates that the indicator in displaying zero MOTION This light is on whenever the scale is in motion Ib Indicates the Ib unit of the displayed weight kg Indicates the kg unit of the displayed weight oz Indicates the oz unit of the displayed weight The unit is g when all units annunciation are dying off 8 1 3 The change of menu F change F9 and add F11 F9 calibration units 1 kg 2 9 F11 auxiliary unit 1 off 2 kg 3 g 4 b 5 0oz 6 lb oz 3 lb 4 oz 8 1 4 Press UNITS key to witch the calibration unit and auxiliary unit For example If you select 1 in F9 and select 4 in F11 press UNITS key then the weight will be switched between kg and Ib If you select 1 in F9 and select 6 in F11 press UNITS key then the weight will be switched between kg and Ib oz 8 1 5 Appendix F11 kg ejg e qef e ee 1kg kg Err5 Err5 Err5 2 20458838lb Err5 a 273414 080z WR Pe bm 3 2lb 3lb30z 1lb 160z 10z oz Err5 0 02835kg 10zZ 10z 0 0625lb Err5 Err5 28 35g 1lb Ib 0 4536k
2. weights if you O e 1 form to prevent data missing in an accident You can key in the data via F17 and F9 Calib Unit select Ib F18 without re calibration Select unit at calibration You 1 2 3 4 Put the set calibration switch to OFF the indicator or will return to the should use kg weights if Valid in PA8101A you select kg See in 8 1 weighing mode 1 Zero Calib Value Span Calib Value F10 oad O standard RS 232 output 1 Communication Mode printout 0 e 6 Operation of the User Menu A 6 1 Entering to the User Menu A When the power is on press the Ib kg or UNITS key and hold then put Setup Calibration Switch to ON the display shows information as below ser gt JL 6 2 User Menu Chart A AD Transits sean Mr AS fata Bas Park AB ID Ma Entry lt Flashing Lol 2400 4200 2600 Disable lovkg Key l Ay zk e AB Additonal Features Peak Hold olal 2 mm Flashing Remark The selection with is valid in model PA8101E 6 3 Use r Menu Description CODE NAME DSCRIPTION CODE VALUE Set baud rate of the RS 232 Baud Rate WE 1200 2400 serial communication when 4800 lt 9600 F10 is O Communication c continuous mode Ca d Mode Lt DU d command mode 8N 8 data bits with no parity bit and 1 stop bit Data Bits and 8N 2 70O 7E Parity 7O 7 data bits with odd parity bit and 1 s
3. respond if a PRINT scale is in motion b scale is in capacity 3 2 Annunciators GROSS Indicates that the indicator is displaying gross weight NET Indicates that the indicator is displaying net weight TARE Flash once when a tare weight has been established in the system MOTION This light is on whenever the scale is motion Ib Indicates lb unit of the displayed weight kg Indicates the kg unit of the displayed weight 4 MENU The indicator includes two menus the setup menu F and the user menu A The Setup menu F containing basic weighing parameters and calibration data consists of 16 selections each with its own selectable sub menu The User menu A containing serial communication parameters ID No printout record number etc consist of 8 selections each also with its own selectable sub menu 4 1 Operation of the function keys in the menu mode 4 1 1 The four keys on keyboard used as direction browser and accept current selection They are shown at Fig 5 O O bd EO Fig 5 4 1 2 Definition of the keys in the menu mode La Entering to the main menu La Entering to sub menu from main menu and scroll down the flashing digit 1 from 1 to 9 keys by press this key at setting the value in sub menu 2 Entering to rights menu in equal class and scroll up the flashing digit 1 from 1 to 9 by press this key at setting the value in sub menu 2 Entering to left menu in equal
4. the weight is greater than A8 or equal with A8 For example if you select A8 100kg when the weight goes up to 300kg the peak hold is 300kg when the weight goes down to 200kg display still 300kg at this time if you press Ib kg button the peak hold will be 200kg 2 The Disable lb kg Key in A4 is invalid when selecting select Peak Hold 9 Specifications and Functions o Non linearity 0 01 F S o Max Input Signal15mV o Input Sensitivity 0 4 u V d o A D Conversion Rate 50 times per second o Internal Count 500 000 o External Count 30 000 o Setup parameter via menu mode calibrate numerically and save in EEPROM o Load Cell Excitation o Voltage 5 0 3 VDC 4X350 load cells Current 80 mA o RS 232 serial communication connector o Display 7 digit 7 segment LED 0 54 high 7 LEDs for status o Operation Conditions o Temperature 0 C 40 C 40 C 20 90 RH o No corrosive gas and no strong EMI is use field 81mm H X 173mm W X 57mm D o Humidity o Dimension Mains AC220V AC120V DC6V OL Materials too much The indicator should have good earthing wire A D no working xamine the wire of the load cell if well change the print 10 ACCESSORIES panel 10 1 INDICATOR 10 2 OPERATOR MANUAL 10 3 QUALIFIED CERTIFICATE 10 4 LOADCELL CONNECTOR 10 5 9 TIN CONNECTOR FOR RS 232 10 6 1AB X G5X20 FUSE 10 7 ASSEMBLED CRUTCH 10 8 ASSEMBLED NUT N sch sch sch sch sch APPENDIX A Error C
5. 1E Front Panel for PA8101A Fig 1 Front Panel Diagram i Loap cei p DCi R282 7 Careta ae apo mo In Fig 2 Back Panel Diagram 2 1 1 Front Panel See Fig 1 a b C 0 54 inch 7digit LED display 7 LEDs GROSS NET TARE ZERO MOT Ib kg legends 5 function keys 2 1 2 Back Panel See Fig 2 a b C d e 14 pin load cell connector Female 9 pin D type connector for the RS 232 serial port Female Input jack for power Male Power Switch 1 ON 0 OFF Setup Calibration Switch 2 2 Connector and its Wiring 2 2 1 Shown at Fig 3 are the pin assignments for the load cell connector Pin Nos Color Wire Name Bienes re Nemes Fig 4 3 FUNCTION KEYS AND STATUS INDICATOR 3 1 Function Keys Function keys in the weighing mode Function keys in the menu mode seeing Fig 4 1 Ib Toggles between Ib and kg units if you select 0 in the User Menu A5 ko FERO Sets indicator to display zero the indicator will not respond if a scale is a not within Zero Range b scale is in motion c scale is overloaded Ee Toggles between Gross and Net weight display only if a Tare has been established GROSS Used to establish a Tare while in either Gross mode or Net node The indicator will not respond if a scale is below zero b scale is in motion c scale is in over capacity i Sends Prints data to printer The indicator will not
6. PA05101 WEIGHT INDICATOR OPERATOR MANUAL XM EL ANE Xiamen Elane Electronics Co Ltd smartachcom 99 5B Huli Da Dao Huli District Xiamen Fujian 361006 China Tel Fax 86 592 602 3169 Email helodesk elane net nemei WWW glaten net www postagescale com www scales r us www chinaeleccomp com www xiamentech com XIAMEN EL ANE ELECTRONICS CO LTD o o 4 e o P WD QUALIFIED CERTIFICATE M odd PA8101 N o 02460132 QC 8B y D ated AN ELANEI entech com i A Xiamen Elane Electronics Co Ltd TABLE OF CONTENTS INTRODUCTION PANEL AND CONNECTORS FUNCTION KEYS AND ANNUNCIATOR MENU OPERATION OF SETUP MENU F OPERATION OF USER MENU A RS 232 COMMUNICATION ADDITIONAL FEATURES SPECIFICATIONS 10 ACCESSORIES APPENDIX A APPENDIX B 1 INTRODUCTION The PA8101 series indicators use a 7 digit 7 segment LED display they have high resolution rapid A D conversion and flexible selection with menus And they have additional features such as counting feature peak hold feature and more units feature They are convenient to use MODEL ADDITIONAL FEATURES waa Common features PA8101 Add more units feature in PA8101 PA8101A Add counting feature and peak hold feature in PA8101E PA8101 2 PANEL AND CONNECTORS 2 1 Panel Distribution D i a B a a Gi TAGOJ HET TARE HO Mt Bo a a a Fe a ZS g RDAS HET ROT EAG E ig o Front panel for PA8101 and PA810
7. class and change the flashing digit from higher to lower SET Accept displayed data of a selection and return to main menu 5 OPERATION of the Setup Menu F 5 1 Entering to the Setup Menu F Put the Setup Calibration Switch to ON turn power on the press the Ib kg key or UNITS simultaneously and when the display shows information as below Only to place the Setup Calibration switch to the OFF if ending or ex iting the Setup Menu then the indicator will return to the weighing mode EES oko laa F5 F E FB Zero Tracking Zar Range Motion Bard Oegital Fitter bsa hala Bel ort ids Se 104 DD F9 F10 Fit F12 Cabbralion Unis Cammunication Mode Aur Unie Print Ticket CA a ker Er so DIR PEHEE HUT Fi7 F18 Manual zero Cail Manual Span Gale F lees arg Remark The selection with is valid in Model PA8101A CODE NAME DESCRIPTION CODE VALUE N selection and stable OFF direction keys and wait for Span Calib MOT LED light out press SET key to save span calibration value See appendix A if display show EER 1 Vianua eck Tor re establish zero calibration value Manual Check or re establish span Remark Factory set defaults are shown bold witha F6 Zero Range The range of zero setting 2 F S 100 F S operation is enabled The MOT LED light out and F7 the weighing operation i e id 2 3d 5d 10d zero tare is enable while motive reading is not exceeded th
8. e limit of this selection L Me H F8 Digital Filter L light M middle Hheavy Select heavier the reading is stable but slower value and span calibration value can be checked in F17 and F18 after F15 and 5 3 Setup Menu Description ones the unit between calibration lz 23 4 5 6 CODE NAME DESCRIPTION CODE VALUE F11 Auxiliary units and auxiliary units in Valid in PA8101A 500 1000 1500 2000 units weighting See in 8 1 F1 Full Scale Full Scale Number of 2500 3000 4000 1 off 2kg 3 g Division X Value of Division 5000 6000 8000 4 lb Sai 6 lb oz 10000 15000 20000 30000 Print Ticket Mode Division Minimum difference between F12 Print Ticket 0 Print GROSS NET TARE F2 two weighing readings Je 2 5 10 20 50 1 Print displayed weight Decimal Pt Decimal point position O 0 0 0 00 0 000 F3 Decimal point position 0 0000 0 00000 P ie aa F15 Zero Clib no load on platform and Overload Display will show __ OL_ wait for MOT LED light out F4 Limit if the reading IS greater than 100 F S 2 110 F S press SET key to save zero the value calibration value Zero Display maintain zero while Enter the value of current F5 Tracking the reading is less than ths 0 5d sc 1d 3d 5d test weights on platform via F16 18 Note The weight value of span calibration is 20 FS at east Zero calibration Sslechunitcarealibration You F16 are being set successfully Please fill the calibration data in the following should use Ib
9. g ee o o o 8 2 The operation description for PA8101E Add A7 and A8 in Menu A AT 0 fTypical 1 Counting feature 2 Peak hold A8 Peak hold Set peak hold is the same with setting A6 8 2 1 Counting Feature 1 Select 1 in A7 2 Make scale stable it must be in Gross mode 3 Press kg lb key until annunciations are die off and display XX 0 then enter into counting mode 4 Press GROSS TARE key to change sample number XX available choices are 5 10 20 50 and 100 5 Place XX units sample items on the scale all at once display XX 6 Press GROSS TARE key display SET for one second then enter into mode of sample number and display YY Remark If the weight of sample is greater than 1 then enter into step 6 If the weight of one sample is less than 1 then change the number of sample items display XX available choices are 5 10 20 50 and 100 7 Press TARE key to exit the count mode then display XX Sample items are ridded off to enter in to step 5 8 2 2 Peak hold 1 Select A7 2 in menu A when the weight is greater than A8 Peak Hold the display goes up with the weight goes up When the weight goes down and greater then A8 and equal with A8 the display keeps on the maximum at this time you can press Ib kg to restart the new peak hold When the weight is less than A8 the display goes down with the weight goes down Theresa in n the display when
10. odes ERROR CODE Input signal of the load cell Examine whether there are Err is too low items on the scale Err2 EEPROM error Change EEPROM ID NO 12345 GROSS 30 0LB ID No 12345 TARE 10 0LB 30 00LB APPENDIX B PRINT TICKET MODE Key in weight value in the Reduce weight value in NET 20 0LB Err3 calibration mode is larger calibration mode or accrete than the full scale capacity full scale capacity Calibration yard is too Reduce calibration divisions Select F12 0 in F Err4 large Errs Unit selected is wrong selected is wrong Mane F9 or F11 ID NO is set in the user menu A6 If A5 select 0 there is ID NO Eeer position selected eg decimal position in F3 Se b ZEN X X A X X when printing nothing when Ad selects 1 Err6 is wrong e weight of one sample eck a greater sample item Err7 is too light unit display is 1 Select F12 1
11. top bit 7E 7 data bits with even parity bit and 1 stop bit Disable the 0 Disable the ID No 0 1 e Ag ce 1 enable the ID No Goen A O Disable the ID No ID No Enable 4 enable the ID No 0 Is Pressing 2 and s key to ID No Entry input ID No and pressing the SET key to store and return to A6 Displaying Axxxxx Prints ID Flashing No Column after ID No being set see APPE A 6bit ID No can be inputed at most when 0 Typica 0 x ar POH 4_ Counting Mode Zenn 2 Peak Hold See in 8 2 Set Peak hold A8 is the same A8 Peak Hold with setting A6 The GE maximum of A8 is 80 FS See in 8 2 7 RS 232 Communication 7 1 Wiring 7 2 Communication Parameters Baud rate set in the user menu A 7 3 Communication Protocol Sign STX 1 the Decimal System CR 13 LF 10 7 4 Consolidated Controls Demand Mode Star Weight Data Transmission Send CVER Stability Polarity when overload Urita Command 1 Motion nr Positive Lei LD GROSS Negative K kg Nr NET T TARE 7 5 Recognized Host Commands PC COM P This command is sent to the indicator to print the indicated display GG This Command is sent to revert to gross mode N this command is sent to the indicator to print the indicated display T This command is sent to the indicator to print the indicated display Z This command is sent to the indicator to Zero the scale

Download Pdf Manuals