Home
POM PDU User Manual
Contents
1. POM PDU User Manual Ver 1 0 11 Control Schedule Control the assigned outlet by pre set schedule Outlet Assign the outlet that want to be controlled in this schedule Every Set week s day assigned day or every day Date When select sgl at column of Every need to input the truly date here Action Begin End ON Turn on outlet at this time None OFF Turn off outlet at this time None OFF ON Turn off outlet at this time Turn on outlet at this time ON OFF Turn on outlet at this time Turn off outlet at this time Active Enable the assigned schedule control 3a PDU Total load 0 0 A Status Normal Information Current Time 2009 09 30 13 59 21 PDU Outlet Every Date Begin End Action Active Susie A B yy mm dd hh mm hh mm ni A Mon o7 59 on wi O Outlet Group B Mon lo7 59 on O Schedule E Mon o7 59 on O Ping Action Configuration D Mon v 07 59 ON 3 o PDU Threshold E Mon de 07 59 ON S O User O Network Mail O SNMP SSL O Time POM PDU User Manual Ver 1 0 12 Control Ping Action Automatically reboot the locked device by ping its IP Ping IP Address Set the device IP that want to be monitored by ping from PDU Response 10 minutes PDU will ping the assigned IP address each minute one time if the equipment has
2. KEEP THE STABILITY OF GETTING POWER INFORMATION AND SYSTEM OPERATION POM PDU User Manual Ver 1 0 5 Web I nterface Login Input the PDU IP address in web browser Default ID is snmp Password is 1234 Connect to 192 168 0 59 The server 192 168 0 59 at Protected requires a username and password Warning This server is requesting that your username and password be sent in an insecure manner basic authentication without a secure connection User name Password F Remember my password o cme POM PDU User Manual Ver 1 0 Information PDU Display total PDU and each outlet power consumption When plug the option device ENV probe it will display temperature and humidity information PDU Total load 0 0 A Status Normal Information PDU PDU PDU1 0 0 A Normal System PDU2 0 0 A Normal Control PDU3 0 0 A Normal Outlet PDU4 0 0 A Normal Group PDU5 0 0 A Normal Schedule PDU6 0 0 A Normal Ping Action PDU7 0 0 A Normal Configuration PDU8 0 0 A Normal PDU Total Current 0 0 A Normal Threshold User Option Device Network Temperature 28 0 C Mail Humidity 49 POM PDU User Manual Ver 1 0 Information System Indicate PDU system information including Model No Firmware Version MAC Address System Name System Contact Location dd PDU Total load 0 0 A Status Normal Information Model No ODIO PDU Firmware Version s4 62 090828 6c
3. POM PDU per outlet monitoring control User Manual Table of Contents 1 AERO OUCTION orinar air a dan 1 2 PDU Package e 2 Se FUNCION si A A A A eee delet eee ae 3 4 Installation A A de 5 5 Web Ntra iia 7 1 Introduction The PDU s an Internet ready device designed and is equipped with an intelligent current meter True RMS that will indicate the total power consumption of a power strip The PDU offers an easy set up and user friendly communication software This software provides the function that assistant manager to remotely monitor the multiple PDU power consumption to realize the total current power consumption and utilization for the enterprises Features Built in web server manager can real time to monitoring the current consumption of the power strip Build in true RMS current meter Setup easily meter can read the IP address directly Homepage support SSL Provide per outlet power consumption Provide audible alarm when the power consumption over the threshold of warning and overload Send the email and traps when the power consumption exceed the trigger value of warning or overload to the PDU Provide utility it can monitor a large mount of PDU at the same time Support the SNMP and provide MIB for the PDU to be monitored by NMS Real time to control outlets of PDU Indicate outlets and circuits status with LED Support power on sequence Schedule control User defined group outlet con
4. User Manual Ver 1 0 19 Configuration SSL Enable SSL for web communication User must input the correct ID and password to enable SSL function The ID and password must be the same with the setting in User ld PDU Total Information Enable SSL O PDU System Control Confirmation ID Outlet Password Group Apply Schedule Ping Action Configuration PDU Threshold User Network POM PDU User Manual Ver 1 0 20 Configuration Time Set the time for schedule control Internet Time Setting Get time from the assigned network time server System Time Input time manually id PDU Total load 0 0 A Status Normal Information Internet Time Setting FEU Time Between Updates 10 minutes System Control Primary Time Server pool ntp org Outlet Secondary Time Server asia pool ntp org Group Time Zone GMT 8 00 vw Schedule Ping Action Configuration System Time 2009 09 30 14 03 41 PDU System Time 2c 99 09 30 14 03 37 Threshold yyyy mm dd hh mm ss POM PDU User Manual Ver 1 0
5. b8s System MAC Address 00 16 18 77 04 59 Control System Name PDU Outlet System Contact Admin Group Schedule Location Office Ping Action Apply Configuration PDU Threshold User Network Mail SNMP S Time POM PDU User Manual Ver 1 0 Control Outlet Indicate PDU outlet on off status and control outlet Select the outlet by checking the box and then click ON or OFF button to control output power for PDU ON Press the icon to turn on the assigned outlets OFF Press the icon to turn off the assigned outlets OFF ON Press the icon to reboot the assigned outlets 34 PDU Total load 0 0 A Status Normal Information Outlet Name Status O PDU OutletA ON O System OutletB ON O Control OutletC ON O Outlet OutletD ON O Group Outlete ON O Schedule OutletF ON O Ping Action OutletG ON O Configuration OutletH ON O pou OFF Threshold POM PDU User Manual Ver 1 0 Control Group Control outlet power for multiple outlets Setting Enter to the setting mode Outlet Assign the outlet in a group Note The outlet number needs to be input by the alphabetical order ON Press icon to turn on the assigned group OFF press icon to turn off the assigned group Active Enable it to be a controllable group d PDU Total load 0 0 A Status Normal Information Outlet Active PDU A B C System Control Outlet Group Schedule Ping Action Configuration PDU Threshold
6. curs PDU can send out email message to pre defined account Email Server The Email Server only support to be input domain name not IP address Sender s Email Input the sender email address Email Address Input the recipient email address The message in the email Indicate OutletA H XXXXXXXX status in order X 0 means the power off X 1 means the power on Note Make sure DNS server can resolve the Email Server s domain name d PDU Total load 0 0 A Status Normal Information Email Setting PDU System Control Email Server mail your com Sender s Email sender yourcom com Outlet Recipient s Email Address Group Email Address harveyhsieh hotmail com Schedule Apply Ping Action Configuration PDU Threshold User Network Mail SNMP SSL ime 4 POM PDU User Manual Ver 1 0 Configuration SNMP When event occurs PDU can send out trap message to pre defined IP address Trap Notification Set receiver IP for trap Community Set SNMP community Read Community is public and fixed Default Write Community is public and can be modified by user d PDU Total load 0 0 A Status Normal Information Trap Notification PDU Receiver IP 192 168 0 1 Control Outlet Community Group Read public Schedule Write public Ping Action Configuration PDU Threshold User Network Mail SNMP SSL Time POM PDU
7. er Manual Ver 1 0 14 Configuration Threshold Set the warning and overload threshold for each circuit Set lower and upper threshold for temperature and humidity 34 PDU Total load 0 0 A Status Normal Information PDU System Control Outlet Group Schedule Ping Action Configuration PDU Threshold PDU1 PDU2 PDU3 PDU4 PDU5 PDU6 PDU7 PDUS Temperature Humidity Threshold Amp Warning Overload 112 116 112 116 12 116 112 16 Lower Upper y POM PDU User Manual Ver 1 0 Configuration User Change ID and password Default ID is snmp and password is 1234 Information PDU System Control Outlet Group Schedule Ping Action Configuration PDU Threshold POM PDU User Manual Ver 1 0 a PDU Total load 0 0 A Status Normal Original ID Password New ID Password 16 Configuration Network PDU network information Enable DHCP Change the way to get IP address for PDU d PDU Total load 0 0 A Status Normal Information IP ieee PDU Host Name DIGIBOARD System Control IP Address 192 168 0 51 Outlet Subnet Mask 255 255 255 0 Group oe Gateway 192 168 0 254 Ping Action Y Enable DHCP Configuration DNS Server IP PDU Threshold Pamay ONSE User Secondary DNS IP Ic 0 0 0 Ne Eze POM PDU User Manual Ver 1 0 Configuration Mail When event oc
8. not responded then number will be increased one time when the continual 10 minutes have not obtained the response the number will display 10 and PDU will carry out the assigned action automatically Action Select outlet action to OFF or OFF ON Active Enable this function 34 PDU Total load 0 0 A Status Normal Information Ping Response Outlet Action Active PDU IP Address 10 minutes System 19 168 23 200 0 Outleta OFF vw O Control Outlet 19 168 23 201 0 OutletB OFF v O Group 19 168 23 202 0 OutletC OFF v O Schedule AAA Ping Action 19 168 23 203 0 OutletD OFF v O Configuration PDU 19 168 23 204 0 OutletE OFF v Fi Threshold 19 168 23 205 0 Outletr OFF w o User Network 19 168 23 206 0 OutletG OFF v Fi Mail SNMP 19 168 23 207 0 OutletH OFF v O POM PDU User Manual Ver 1 0 13 Configuration PDU Set the outlet name and delay time Name Rename the outlet ON Set delay time for power on sequential OFF Set delay time for power off sequential Note The maximum delay time is 255 seconds 3d PDU Total load 0 0 A Status Normal Information ON OFF PDU Name Delay Delay Sot zmz oo ft Outlet 2 de Schedule TERE OutletD A Quieto Je Configuration si PDU OutletF f6 e Threshold OutletG 7 jf User a OutletH a le Mail SNMP SL POM PDU Us
9. on of equipment nameplate ratings should be used when addressing this concern E Reliable Earthing Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit e g use of power strips Diagram PDU Install In the Rack gt PDU Install In the Rack mF PDU Install In the Rack Remote Monitor The multiple PDU power o PDU Install In the Rack gt lt PDU Install In the Rack Local Monitor e PDU Install In the Rack POM PDU User Manual Ver 1 0 Hardware 1 Install mounting brackets 2 The PDU comes with brackets for mounting in a rack To mount the PDU into a rack performs the following procedure 3 Attach the mounting brackets to the unit using the four retaining screws provided for each of the brackets 4 Choose a location for the brackets 5 Align the mounting holes of brackets with the notched hole on the vertical rail and attach with the retaining screws 6 Connect input and output power 7 Connect Ethernet cable to the PDU 8 Switch on the PDU Note 1 The default setting for the way to get IP address is DHCP If PDU can not get the IP from DHCP server the IP address will stay at 192 168 0 216 Note 2 TO SETUP THE NETWORK SYSTEM FOR PDU STRONGLY RECOMMAND TO BUILD UP THE POWER MONITORING NETWORK SYSTEM ISOLATED WITH THE OTHERS IN ORDER TO
10. r bank or PDU LED Indicator SSL yellow Light on means that web access is protected by SSL DHCP green Light on means that PDU gets IP address through DHCP PDU green Indicate each output power status Status red Indicate each circuit status POM PDU User Manual Ver 1 0 ENV RJ11 for option ENV probe attached to detect temperature and humidity Circuit Breaker Overload power protection POM PDU User Manual Ver 1 0 4 Installation This section will provide a quick instruction to install the PDU Rack Mount Instructions A Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature specified by the manufacturer B Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised C Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading D Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on over current protection and supply wiring Appropriate considerati
11. trol Auto reboot the locked device by pinging its IP Support network time protocols Option accessory can support temperature and humidity detection POM PDU User Manual Ver 1 0 2 PDU Package The standard PDU package contains a Power Distribution Unit with supporting hardware and software The components of the package are Power Distribution Unit Rack mount Brackets CD ROM it contains User Manual PDU Software MIB Management Information Base for Network PDUMIB mib Adobe Acrobat Reader POM PDU User Manual Ver 1 0 Interface Functions Description Ethernet RJ 45 port for network communication port Audible Alarm Warning 1 beep in 1 second Overload 3 beeps in 1 second Note The audible alarm will keep beeping until the current gets back to normal and the current is lower than the threshold to 0 5 amps Function Button e Press and release to turn off the warning beeping The overload beeping can not be cancelled e Press and hold the key after 1 beeping it can let the meter to show up the current information and temperature humidity in sequence e Press and hold the key after 2 beeping it can let the meter to show up the IP address Press and hold the key after 4 beeping it can change the way to get IP by DHCP or Fixed IP Press and hold the key after 6 beeping it can reset PDU back to default setting Meter 3 digits to display current and IP Address ID The identification of powe