User manual CuroCell® AREA - Bridgeway Medical Systems
Contents
1. Care of sweden User manual 2010 12 21 CuroCell AREA Self adjusting pressure care mattress User manual item number 95 001064 oO as rie ho Mais a e OR e ee CE S Contents Important safety precautions Introduction Product description Instruction for use Cleaning and reconditioning Storage Troubleshooting Technical description Spare parts Options and accessories Warranty Other information Own notes GO ON UU HR L 10 11 12 14 15 16 17 18 IMPORTANT SAFETY PRECAUTIONS Read all instructions prior to use WARNING 1 The product must only be used for its intended purpose as described in this manual The product may not be combined assembled or repaired with other parts accessories or spare parts other than those described in this manual or other documentation from Care of Sweden 2 The mattresses are protected by a hygiene cover avoid using other covers in combination with the mattress 3 DO NOT USE in the vicinity of or in contact with fire sources hot surfaces such as fire burning cigarettes or hot lamps Although the product has undergone fire testing it could become damaged if it comes into contact with fire sources 4 Position and use the product in a manner that prevents it from becoming trapped or damaged NOTE Be particularly aware of trapping damage when using bed rails 5 Always make sure the mattress has th
2. Class Il equipment Double Insulated a oo Foot placement Not in domestic refuse follow recycling instructions SE Lt Directly on bed base R Not directly on bed base gt s Place on top Machine wash at 70 C Do not tumble dry A Read the user manual H Type BF equipment AX Recommended user weight Grounded contact Fire classification gt 120cm Recommended minimum length Length of warranty mas Recycling m m Place on top of existing mattress Not on top of existing mattress L mb C Place underneath Machine wash at 95 C Tumble dry Ry A Do not dry clean 1 Chlorine 13 CE CE marked acc to MDD 93 42 ECC CATEGORY 1 2 3 4 L d L J L d L J Patient information category R U The mattress should only be used lying in the lengthwise direction on the mattress Do not turn Al Do not iron m Drip dry XX Do not use chlorine 8 Spare parts Art no Description Size CC 900050 Air cell AREA 1 pcs If other spare parts are needed please contact Care of Sweden or your local dealer for further assistance 14 9 Options and accessories 9 1 Options Sturdy transport bag Transport and storage bag 9 2 Accessories Art no CC 925511 CC 925512 CC 925513 CC 925514 CC 925515 CC 925516 CC 925517 CC 925519 58 900906 Description Cover Steel top part Cover Steel top p
3. art Cover Steel top part Cover Steel top part Cover Steel top part Cover Steel top part Cover Steel top part Cover Steel top part Transport bag 9 3 Other accessories Size 80x200 cm 80x210 cm 85x200 cm 85x210 cm 90x200 cm 90x210 cm 105x200 cm 120x200 cm To ensure the best level of comfort we recommend use of accessories from Care of Sweden since our products are designed to work well together Please contact Care of Sweden or your local dealer for accessories or more information on our products 15 10 Warranty 10 1 Scope This CuroCell system is covered by a 3 year warranty for manufacturing defects The warranty does not apply to normal wear and tear or product impairment or damage stemming from negligence or improper handling care 10 2 Service and repairs This CuroCell mattress is a medical device in accordance with MDD 93 42 EEC that is used as an aid in preventing and treating pressure ulcers Service and maintenance must always be performed by Care of Sweden or one of its authorised technicians Only use spare parts that have been approved by Care of Sweden Use of non approved spare parts invalidates the warranty A warranty claim must be submitted to Care of Sweden before the product is returned Please contact Care of Sweden or your local dealer if you have questions regarding warranty and service 16 11 Other information 11 1 Disassembly and recycling A used CuroCell mattress mu
4. ary 3 After afew minutes the product is ready to be used 3 2 Hand check Hand check is used to ensure that the function of the mattress is correct This should be done regularly Open the cover and insert your hand between the air cells directly underneath the user s pelvic region use a vertical hand There should be a clearance of 2 3 fingers between mattress base and the patient If not you need to check cells and tubing If the problem is not resolved please contact Care of Sweden or your local dealer 4 Cleaning and reconditioning It is important to follow the instructions below before using the product for a different user Consult the hygiene responsible or the supplier for help and instructions when unsure NOTE Check the hygiene cover each time the product is cleaned If damaged it must be replaced or repaired 4 1 Covers MATTRESS COVER Covers can be wiped off with a mild cleaner e g washing up liquid and water or with an alcohol based disinfectant cleaner intended for this purpose Perform Virkon or Desisoft can also be used Excrement and blood spots must be removed immediately with cold water Carefully follow local instructions and usage instructions for the cleaner te O m GS Multi layer covers should be divided before washing Wash with like colors Chlorine and phenol based cleaners could have a negative impact on the PU surface PET and should be avoided If chlorine is used we recomm
5. e right size 6 The hygiene cover does not allow liquid or air to penetrate but is vapour permeable Make sure that the patient is positioned correctly to avoid the risk of suffocation 7 Prevent damage to the hygiene cover from sharp objects 1 Introduction Always read the user manual prior to use 1 1 General information This system is a medical device with CE marking in accordance with MDD 93 42 EEC The system has been tested and approved according to the following standards SS EN ISO 12182 EN 597 1 SS EN ISO 14971 EN 597 2 SS EN ISO 10993 EN 14126 1 2 Intended use CuroCell AREA is a replacement mattress and can be used in all types of health care environments The mattress is intended to assist in the prevention and treatment of pressure ulcers up to and including category aN The recommended user s weight is 30 230 kg The mattress must always be cleaned between patients sD SSE eee ee eee ee ee ee ee ee eee eee eee eee eee NOTE When used together with positioning pillows read the pillow user manual carefully for correct positioning of the patient If you are using this product with an evacuation sheet it is the user s responsibility to ensure that it is safe to use for evacuation Be careful when using bed rails or other protection on the bed so that the mattress does not become crushed or damaged The mattress must not be lifted with a person lying on it or used for any other type of s transport
6. end a mixture of max 1 INNER COVER i Ohl lG A Clean the affected area using a mild cleaner e g washing up liquid and water or with an alcohol based disinfectant cleaner intended for this purpose Perform Virkon or Desisoft can also be used 4 2 Foam core Clean the affected area with a mild cleaner e g washing up liquid and water or with an alcohol based disinfectant cleaner intended for this purpose Perform Virkon or Desisoft can also be used Press out the water carefully Let the foam core dry in a warm ventilated area without direct exposure of sunlight The foam core needs to be completely dry before it is used again 4 3 Air cells 1 Remove the covers See instructions in chapter 4 1 for cleaning covers 2 Carefully remove the air cells from the foam core Remove the cell holder from the cells 3 Place the air cells and the tubes on a clean area which is suitable for washing 4 Wipe off cells and tubes with alcohol based disinfectant cleaner intended for this purpose Perform Virkon or Desisoft can also be used Allow to dry 5 Replace the cells into the cell holder Place the air cells back into the foam core Check that all the tubes and connectors are secure and tight before closing the cover 6 Wipe off work surfaces with alcohol based disinfectant cleaner intended for this purpose Perform Virkon or Desisoft can also be used If cells for any reason have loosened from the tubes these must be rep
7. laced according to drawing in chapter 2 1 5 Storage Store the mattress on a flat surface or carefully rolled folded with the zipper closed Always store at room temperature in a dry area Make sure the mattress is stored where it will not be exposed to thrusts hits or other things that can damage it Avoid direct exposure of sunlight If the mattress is to be stored more than 3 months we recommend it is stored on a flat surface not folded or rolled up 10 6 Troubleshooting Problem Solution The patient is bottoming out Open covers and check cells and tubing Check again using a Hand check see section 3 2 If your questions are not answered by the above information please contact Care of Sweden or your local dealer 11 7 Technical description 7 1 Technical specification MATTRESS SPECIFICATION Dimension BxLxH 80 85 90 105 120x200x18 cm 80 85 90x210x18 cm 16 ke 80 200 cm NOTE The manufacturer retains the right to modify the product specification at any time WARNING Follow the operations and maintenance instructions carefully in order to prevent bodily injuries as well as damages to the product or other equipment 7 2 Labeling The mattress is labeled with product name article number production date size bar code as well as care and wash instructions The product also displays what side is up down and head foot 12 7 3 Symbol Definitions XXXX XX XX Year Month Day IS
8. other than a possible evacuation using an evacuation sheet 1 European Pressure Ulcer Advisory Panel Quick reference guide 2009 2 Product description The CuroCell AREA is available in the following sizes Width 80 85 90 105 120 cm length 200 cm and width 80 85 90 cm length 210 cm For other request please contact Care of Sweden or your local dealer Because of its unique construction combining foam and air this mattress provides high user comfort as well as a solution for pressure care without the need for external pump or electricity The system uses patient weight and movements to distribute the internal air reservoir amongst the cells in order to always maintain low surface pressure The CuroCell AREA is delivered with a liquid resistant and vapour permeable hygienic cover with welded seams An inner cover is also included The mattress has a built in heel slope for protection of heels 2 1 Mattress drawing 1 Label for Head end 2 Tubes 3 Air cells 4 Foam core Tube system Huvud Head Ventil Check valve Tubing system including extra cell in foot end Head AHA 3 Instruction for use 3 1 Unpacking the mattress The mattress is packed in a box 1 Start with making sure that the package is not damaged When opening the box and any other protective material avoid using a knife since this could damage the mattress and cover 2 Put the mattress on the bed frame and correct the cover if necess
9. st be taken to a recycling centre and sorted as combustible waste For more information contact Care of Sweden or your local dealer 17 12 Own notes 19 m i Manufactured by care of sweden Contact Phone 46 771 106600 Fax 46 325 12840 Email info careofsweden se Internet www careofsweden com Address Care of Sweden AB Box 158 SE 512 24 Svenljunga SWEDEN Visit cargo address Bor sv gen 14 SE 512 53 Svenljunga SWEDEN Supplied by Care of Sweden AB 2010 Care of Sweden and CuroCell are trademarks of Care of Sweden AB 20
Download Pdf Manuals
Related Search
Related Contents
Getting the best from your urn Instructions for use Samsung M1733N دليل المستخدم www.prolight.co.uk Order Code: MIXE07 Samsung CJX-1000 Benutzerhandbuch Simpli Home 3AXCDEV-02 Instructions / Assembly BBA 13/5015 - MBC Project Vector Xpression Tutorial: Latin Squares/Dye Swap Analysis 3月号 Copyright © All rights reserved.