Home

AplusWEB AW-920 User Manual

image

Contents

1. Link Layer Topology Discovery Mapper 1 0 Driver wi Link Layer Topology Discovery Responder Description Transmission Control Protecol Intemet Protocol The default wide area network protocol that provides communication across diverse interconnected networks Figure 15 15 Internet Protocol Version 4 TCP IPv4 Step 4 Select Use the following IP address and in the P address field enter a suitable IP address for your PC such as 192 168 1 100 This is your PC s static IP address In the Subnet mask field enter 255 255 255 0 Leave the Default gateway field blank You may leave the Obtain DNS server address automatically as it is Internet Protocol Version 4 TCP IPv4 Properties P X General L You can get IP settings assigned automatically if your network supports this capability Otherwise vou need to ask your network administrator for the appropriate IP settings 3 Obtain an IP address automatically 89 Use the following IP address IP address 192 168 1 100 Subnet mask 255 255 255 0 Default gateway Obtain DNS server address automatically Use the following DNS server addresses Preferred DNS server Alternate DNS server Validate settings upon exit Figure 15 16 IP Configuration Example End of Document 46
2. 192 158 1 100 Figure 15 4 TCP IP Settings Step 5 Restart the PC for the settings to take effect Figure 16 5 Em oun Windows Figure 15 5 Shutdown Menu 40 Linkwise Technology Pte Ltd Internet Protocol TCP IP Properties Setting a Static IP Address for Windows 2000 Windows XP Step 1 Right click on the My Network Places icon on your desktop and select Properties My Network Places Figure 15 6 My Network Places icon Step 2 Right click on the Local Area Connection icon and select Properties Lacal Area Connection LAM or High Speed Inter Connected Figure 15 7 Local Area Connection icon Step 3 Double click on nternet Protocol TCP IP and you will see the window Figure 15 8 General You can get P settings assigned automatically if your network supports this capability Othermise need to ask your network administrator the appropriate IP settings Obtain an IP address automatically Use the following IP address address Subnet mask Je fault gateway Obtain ONS server address automatically Use the following ONS server addresses Prefered DHS server Altermate DNE server Figure 15 8 IP Configuration AplusWEB User Manual 41 Linkwise Technology Pte Ltd AplusWEB User Manual otep 4 Select Use the following IP address and in the P address field enter a suitable IP address for your PC such as 1
3. Warranty card Linkwise Technology Pte Ltd AplusWEB User Manual Getting to know your product Figure 3 1 O e meme _ b swasnusssescewtmns PowramOsedon _ Table 3 2 LED Indicators Description Table 3 3 shows the description of the LED Indicators colour and its functions Function O Power Module is running in normal mode Flashing Orange GSM in operation LowSig Re No SIM card inserted or RF signal strength is below 30 Table 3 3 Telco Signal Strength LED Indicators After applying power to AplusWEB the green Power LED and the Low Sig LED will light up After few seconds the amber Telco LED will start to blink 0 5s on 0 5s off This rate of blinking indicates that AplusWEB is searching for a valid Telco network When it succeeds logging onto a network the Telco LED will flash 0 25 on 0 85 off If the received Telco signal strength is high enough 23095 the Low Sig LED will turn off Linkwise Technology Pte Ltd AplusWEB User Manual Under normal condition the Error LED should be off If lighted it indicates either SIM card is not present or The card is locked and the mobile pin code is not supplied or wrongly entered Refer to software configuration section on entering mobile pin code Low Sig LED with lighted suggests that the signal strength is too low for reliable SMS operation If this happened either relocate AplusWEB to a nearby location where the R
4. 29 Linkwise Technology Pte Ltd AplusWEB User Manual Chapter 11 Administration Page This page gives you administrator control over AplusWEB Device ID Max 15 characters AWS20 AplusWEB v Date 09 12 2011 New Time hh mm ss Synchronise with NTP server IP Address 192 168 1 87 Subnet Mask 255 255 2550 192 168 1 1 Automatically check and send telco signal strength Enable Day Daily Time 10 00 mm Figure 11 1 Admin Page Change Device ID This entry is for the Administrator to assign a unique name to AplusWEB It accepts up to 15 alphanumeric characters The device s name will be SMS along with other information when an alarm is triggered It is advisable to change the Device ID according to the location or site name as the user will still know which location the SMS alert came from even if there was a change in the device s SIM card number Device ID Max 15 characters Figure 11 2 Device ID Change Date amp Time Enter the new date and time in this field The date and time should use the following format date month year dd mm yyyy and hour minute second hh mm ss For setting the real time clock of AplusWEB Date and time information are also sent to mobile phone s when an alarm is triggered 09 12 2011 New Time 09 38 29 hh mm ss Figure 11 3 Date amp Time 30 Linkwise Technology Pte Ltd AplusWEB Us
5. AplusWEB User Manual Version 1 0 Model AW 920 5 33932 5593 5 Model A W 92U Important Please read this user manual carefully before using this device Table of Contents CHAPTER E INTRODUC HON coc Mo pues desi oa eve x 2 CHAPTER 2 SAFE USE OF DEVICE boc e va dece co Edi du tke Que RBS Hle oko ra aseo ted ise 3 CHAPTER S PRODUCT OVERVIEW pue EE a Eee IE ead DRESS Mura 6 CHAPTER 4 HARDWARE _ nm nnn n rnn nnn 10 INTERFACING TO EQUIPMENTS iioii hortaretur Berne n e ba ou o Eee ba epi Eia tad fun 13 WIRING INSTRUCTION EXAMPLE 13 CHAPTER 5 SOFTWARE CONFIGURATION CERE ca Ua REOS oss 14 STANDALONE CONFIGURATION STATIC IP I Innen n nnn nnne n nnne nnn nnn nnn nnn nana nnn nnn nnns 15 CHAPTER LOGIN PAGE EN oa ep SL desees eee Eso pee Pera EAD 16 CHAPTER 7 STATUS PAGE ee Sea es eee dat 17 CHAPTER 3 INPUT CONFIG Uds Cohes Regan Eg a 19 IO CONFIGS EXAMPLE as agate RI LIES LE EE M 20 IO CONFIG EXAMPLE 2 4 20 ANALOG CONFIG totiens mint di eU net E M MI eee ee M ES 21 CHAPTER 9 PHONE GROUP PAGE iive RE
6. AplusWEB is possible without causing false triggering In noisy environment shielded cables are recommended Unused inputs can be left unconnected Wiring Instruction Example Figure 4 4 shows the power supply connection to AplusWEB Power to AplusWEB can be from 12 18 Volts A 12VDC adapter is supplied as a standard accessory The digital inputs shown are dry contacts type The two outputs are relay types with contact ratings of 30V 2 amps DC max Also shown in this figure are two 4 20mA transmitters 2 wire loop powered Depending on the power requirement of the transmitter a higher voltage may be needed In this case change the power supply to a higher voltage type but not higher than 18 volts AplusWEB is also capable of driving low power loads directly without using relay interface The output driver is an open collector transistor each can sink up to 500mA of load current Maximum handling voltage is 30 VDC Always connect a diode across the load to protect the transistor from damage due to back EMF especially inductive loads X1 x2 coM x3 x4 COM x5 X6 com xT xE AplusWEB TELCO Low SIG POWER FD Model AW 920 2 Aq A2 Va 4 20 mA To DC12 24V DC12 24V refer to transmitter spec POKER RC ETHERNET Figure 4 4 Wiring Diagram Example 13 Linkwise Technology Pte Ltd AplusWEB User Manual Chapter 5 Software Configuration Configuration of messag
7. User Manual Setting a Static IP Address for Windows 7 Step 1 Click Start gt Control Panel gt Network and Sharing Center otep 2 In the Network and Sharing Center folder select Local Area Connection View your active networks Connect or disconnect Access type Internet Network 2 Home raup Available ta join Home network P Connections Local Area Connection Figure 15 13 Local Area Connection icon Step 2 In the Local Area Connection Status folder click the Properties button m Local Area Connection Status IX General Connection IPv4 Connectivity Internet IPv6 Connectivity Mo Internet access Media State Enabled Duration 01 28 41 100 0 Mbps Received 1 336 961 4 300 606 Properties Disable Diagnose Figure 15 14 Properties Button 45 Linkwise Technology Pte Ltd AplusWEB User Manual Step 3 In the list of installed network components select Internet Protocol Version 4 TCP IPv4 and then click the Properties button t Local Area Connection Properties seo _ Metworking Connect using amp Broadcom NetLink TM Gigabit Ethemet Configure This connection uses the following items Iv OM Client for Microsoft Networks Virtual PC Network Filter Driver G05 Packet Scheduler File and Printer Sharing for Microsoft Networks Intemet Protocol Version m intermet Protocol Version 4 TCP IP wah
8. X1 is use as a status monitoring input select the None radio button In this selection no SMS is sent when the input changes states 1 Power Supply in Basement 1 Fault e Figure 8 3 Digital Input X1 Alarm None Status Alarm state None x1 Power Supply in Basement 1 Normal Figure 8 4 Status X1 Contact Open X1 Power Supply in Basement 1 Fault Figure 8 5 Status X1 Contact Close Input Config Example 2 Below is an example of defining the input state X1 as a contact Close as alarm Input Config Alarm state Close Figure 8 6 8 8 shows Input X1 set to Alarm State Close If X1 is set as contact close on alarm select the Close radio button In this selection SMS will be sent out when the input X1 changes from Open to Close state 20 Linkwise Technology Pte Ltd AplusWEB User Manual Input Config Alarm state Close r Figure 8 6 Digital Input X1 Alarm Close Status Alarm state Close Power Supply in Basement 1 Normal Figure 8 7 Status X1 Contact Open n TE X1 Power Supply in Basement 1 Fault Figure 8 8 Status X1 Contact Close Input Config Completed Table Figure 8 9 shows an example of a completed input configuration table 1 PowerSupplyin Basement Noma Faut o o e MainDoorin Reception Figure 8 9 Digital Input X1 X8 Analog Config Two channels of 4 20
9. a heater e Placing or Moving Do not place this device on an unstable cart stand tripod bracket or table The device may fall and cause serious damage to itself and serious injury to others A device and cart combination should be moved with care Quick stops excessive force and uneven surfaces may cause the device and cart combination to overturn e Power Sources The AC adapter should be operated only from the type of power source indicated on the marking label If you are not sure of the type of power supply to your premises consult your device dealer or local power company e Power Cord Protection Power cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them Pay particular attention to plugs and the point from which the cords exit the device e Outdoor Antenna Grounding If an outside antenna is connected to the device be sure the antenna is grounded so as to provide some protection against voltage surges and built up static charges e Lightning For added protection of this device during a lightning storm or when it is left unattended and unused for long periods of time disconnect it from the wall outlet and disconnect the antenna This will prevent damage to the device due to lightning and power line surges e Power Lines An outside antenna system should not be located in the vicinity of overhead power lines or other electric light or power circuits or wh
10. query the status of Inputs outputs and perform system checks AplusWEB will reply the current state of the Input and Output and the System status using the respective commands us SMS Command SEU AC Comment Command Action Operation N input 1 input alarm none or Output output name output yes yes status op output name description Analog Input 2 analog input name yes yes ai room tem nti status analog input name p analog description Query all System reply with IO status 210 210 yes yes I Os N Normal or A Alarm Query oystem reply with Telco system syscheck syscheck yes yes signal strength status Table 12 3 Query IO amp system status Output Control Operation and authorized users can switch the 2 outputs ON or OFF by sending the commands below SMS Remote SMS Command Sample Comment Rights Action Command Operation Authorizer output name output Switch on output Zon output name on siren description output name output Switch off output Zoff output name off siren description Table 12 4 Output Control 34 Linkwise Technology Pte Ltd AplusWEB User Manual Configuration Authorized users can change configuration description and alarm state by sending the commands below SMS Remote Rights SMS Command Sample Command Comment On SMSCommand Sample Command Operation Authorizer 8 Add X1 UPS Normal Alarm i Replace Input ipd XN d o c no
11. repeatedly according to the number of times specified to the operation and forward group SMS Repeat Interval SMS repeat duration 2 30mins 25 Linkwise Technology Pte Ltd AplusWEB User Manual SMS Settings Repeat SMS on Alarm State None C Once 2 Times 3Times 4 Times SMS Repeat Interval minutes 2to 30 minutes Note SMS Repeat will be cancelled on receiving the ack command Send SMS when status returns to normal Yes C No Figure 9 5 SMS Settings To cancel repeat sending any mobile phone from the operation or forward must acknowledge to AplusWEB by replying the acknowledge command Zack This command is non case sensitive Zack Ack are valid strings AplusWEB upon receipt of the acknowledge command stop sending further SMS to this alarm If multiple alarms are triggered only the first SMS alert will be repeated Subsequent alarms are sent once This is to prevent the recipients from unnecessary annoyance and saving on SMS costs After the alarm or alarms was acknowledged new alarms triggered will be sent and repeated until the next ACK command is received by AplusWEB Set to None if repeat SMS is not required Send SMS when status returns to normal If Yes is selected SMS will be sent once when status of Digital Input or Analog Input changes from Alarm to Normal state There is no repeat for this Normal SMS If No is selected SMS will not be sent out when status of Digital Input or Analog Input
12. yes ipd description description X1 UPS Alarm Normal open state close state Add Replace opd YN d opd Y1 siren N output 1 or 2 yes Output description iaXtdose iaXtdose close Set Change j ipa E Input alarm B input alarm yes state ipa 2 close Table 12 5 I O Configuration Repeat Configuration Authorized users can change the SMS alarm repeat settings sending the commands below To cancel repeat sending any mobile phone from the operation or forward must acknowledge to AplusWEB by replying the acknowledge command ack SMS Remote SMS Sample Comment Action Command Command a ee N number of times rp oet RASSE of rot N SMS repeat repeat times rpt 0 O disable repeat Set repeat repeat time interval rpt time rpt time 5 M yes interval In minutes Query repeat oystem reply with repeat rpt rpt l yes yes status interval System reply with Ack Acknowledge Zack Zack received Sms repeat yes yes repeat alarm stops Table 12 6 Repeat Configuration 35 Linkwise Technology Pte Ltd AplusWEB User Manual Remote SMS command Benefits With the remote command functionality above it saves time and effort O Re assigning of operation personnel a change of mobile phone number is also common Rather than having to physically go to the installation site with a notebook computer the aut
13. 92 168 1 100 This is your PC s static IP address In the Subnet mask field enter 255 255 255 0 Leave the Default gateway field blank You may leave the Obtain DNS server address automatically as it is Internet Protocol TCP IP Properties E 2 General You can get P settings assigned automatically if your network supports this capability Othermise need to ask your network administrator the appropriate IP settings C Obtain an IP address automatically f Use the following IP address IP address 132 1568 1 100 Subnet mask 255 2565 25h Default gateway DHS server address automatically f Use the following ONS server addresses Preferred ONS server Advanced Alternate DNS server Figure 15 9 IP Configuration Example Step 5 Click the subsequent OK buttons to accept the settings and to close the windows until you get back to the desktop Your IP settings are now correct 42 Linkwise Technology Pte Ltd AplusWEB User Manual Setting a Static IP Address for Windows Vista Step 1 Click Start 2Settings 2 Network Connections Step 2 In the Network Connections folder select Local Area Connection E Network Connection LAN or High Speed Internet 1 Figure 15 10 Local Area Connection icon otep 3 Right click the connection icon and choose Properties from the shortcut menu Step 4 Click Continue Step 5 In the list o
14. F reception is better or if relocating is not possible or practical use an external high gain antenna Contact your distributor for a suitable recommendation to your situation Linkwise Technology Pte Ltd AplusWEB User Manual Chapter 4 Hardware Installation This section will guide you through the installation of your AplusWEB Just follow the instructions here and you will have your AplusWEB installed very quickly Before starting installation ensure that the unit is powered OFF and the power adapter plug disconnected from the POWER connectors of the unit Mounting Determine a suitable location for the AplusWEB Mount the AplusWEB on the Din Rail as illustrated below Figure 4 1 Figure 4 2 1 Slide the top of AplusWEB on to the DIN rail Figure 4 1 2 Push the bottom of AplusWEB on to the DIN rail Figure 4 1 3 Use a screw driver to push the lock upwards Figure 4 2 Step 1 Determine a suitable location for the AplusWEB when selecting a location remember that you will need to connect the power adapter termination blocks and Ethernet cable and have suitable GSM reception Follow carefully the instructions provided earlier in this manual on the safe use of this device and the instructions above on mounting the AplusWEB on to the Din Rail 10 Linkwise Technology Pte Ltd AplusWEB User Manual Step 2 Insert a valid GSM mobile telephone SIM card into the SIM card socket slot on top of the AplusWEB To inse
15. Room Temp Hormal 20 0 degree Figure 8 15 Status Analog Input A1 Normal State 23 Linkwise Technology Pte Ltd AplusWEB User Manual Chapter 9 Phone Group Page This page shows the user telephone numbers organized into 8 indexes operational group 2 users in authorizer group amp 1 user in forward group Click Apply for any changes to take effect If applicable contact your mobile telephone service provider for the correct way to represent overseas and local telephone numbers Repeat SMS on Alarm State None Once 2 Times 3 Times 4 Times SMS Repeat Interval E minutes 2 to 30 minutes Note SMS Repeat will be cancelled on receiving the amp ack command Send SMS when status returns to normal Yes No Sim Card Pin Code Note Leave blank if Sim Card is not locked Apply Cancel Figure 9 1 Phone Group Operation Group This group of users is those that will receive alarm SMS when one or more digital inputs are activated open close close open Analog Input are activated normal high high normal normal low low normal Up to 8 mobile phone numbers can be assigned to this group Phone numbers of up to 20 numbers and are valid formats Example 98175004 6590889650 1 98175004 2 46590889650 3 495260947165 4 E M WM LL Figure 9 2 Operation Group 24 Linkwise Technology Pte Ltd AplusWEB User Manual Authorized Group This group can perform query
16. S EGS CER ES 24 OPERATION GROUP 24 AUTHORIZED GROUP seat atari acta 25 FORWARD NUMBER anna 25 SMS SETTINGS sat 25 CHAPTER 10 OUTPUT CONFIG 2 VER UE ERE 28 REMOTE CONTROL OUTPUT USING SMS seen nnn nnn n nnne nenne nennen nnne 28 CHAPTER 11 ADMINISTRATION 30 CHANGE DEVICE ID 5 30 CHANGE DATE amp TIME i MU MM dana I M IDCM ania etna 30 NTP SERVER La 31 CHANGE ADMINISTRATOR PASSWORD detegit eeu las decies a Ee 31 CHANGE GUEST PASSWORD 5 vu pce aepo tno Led taut aepo 31 NETWORK GONFIGUBATION c ibit otra rh osi tro fa d us catre dob t rea d des outta to teta d dus iets 32 CHAPTER 12 HELEP 33 QUERY MOBILE PHONE NUMBERS eRIRRRRRR ee Hmm m nn nn nnne nennen nn nn nnn nn 33 PHONE MANAGEMENT iai tots sucre cs opuesto Co ode aco b ues depu ette Posto es uate ld cules dos pete E Mrs CE LR Me anes 33 QUERY IO amp SYSTEM STATUS oberen Maso aotem M 34 OUTPUT utbs inde to estu
17. This page shows the example of a completed input output configuration Status Page Once the administrator configured successfully the screen on the right side of the browser will display the updated table showing the description the devices or equipment and the present status The devices or equipment are those that are interfaced to AplusWEB termination block Relay outputs and Analog input are also shown on this same screen AplusWEB Ans PICOBOX Mode MENU Device ID AW920 AplusWEB GSM Network STARHUB Login Administrator 09 12 2011 IP Address 192 168 1 87 Static Signal Strength 64 Battery 12 0 Volts 09 34 40 A Phone Group x1 Power Supply in Basement 1 Normal Administration x2 Water Detection System Water Detected About Aircon in Server Room Running Help X4 Poolside Emergency Button Normal toat X5 UPSin Server Room Normal Fire Alam Panel in Security Room Normal Booster Pump in Pump Room Running Main Door in Reception Door Opened Buzzer OFF Beacon Light OFF Server Room Temp ma 24 5 Degree C Server Room Humidity Low Alarm 37 0 RH Copyright 2011 by Linkwise Technology Pte Ltd All Rights Reserved Figure 10 2 Status Page example Sensor status colour indicator The colours Red and Green indicate at a glance the status red is critical and green is in the normal state Black indicates user had defined the equipment as non critical
18. alc a tees ds eda 34 IO CONFIGURATION Gu mis MIDI IM C PMID 35 REPEAT CONEIGURATIONG ihe Etre veg Luna bec iau eue Cosi i ve vag unten cue focused a 35 CHAPTER T3 ABOUT PAGE aw ee sexa Eu ere reu xm Su 37 CHAPTER LOGOFF PAGE tu adu Sap Rd SEE i MINCE M M ELM V VES 37 e 38 SETTING A STATIC IP ADDRESS FOR WINDOWS 968 38 Linkwise Technology Pte Ltd AplusWEB User Manual SETTING A STATIC IP ADDRESS WINDOWS 2000 WINDOWS XP 41 SETTING A STATIC IP ADDRESS FOR WINDOWS VISTA 0 0 0cccecccescceseeeeeeeeeeeeeceeeaseeeeeeseeesaeesaeeseeesaeeseeenes 43 SETTING A STATIC IP ADDRESS FOR WINDOWS 7 cccccccceeccecceeeeeseeeeeeaeeaeeeeeeeaecseeeeecseeeeaeesaeeseesaeenes 45 Chapter 1 Introduction Thank you for your purchase of PICOBOX AplusWEB AW 920 This device has lots of powerful built in features and functionalities yet it is easy to setup and to use You are advised to read through this manual to understand each feature in detail so as to fully utilize the capabilities of this product AplusWEB is an alarm controller and also a SMS gateway When used as an a
19. and changing of Operation Forward and Authorizer mobile phone numbers stored in the units memory Users in this group can also change the configuration of IO This group of users will not receive any alarm SMS when digital inputs are activated Authorized Group Max 15 numeric characters 1 2 Figure 9 3 Authorized Group Forward Number This number if assigned will receive alarm SMS like the operation numbers Any incoming SMS to AplusWEB will also be forwarded to this number as well This is a very useful feature where an organization wishes to have a central logging of all activities alarms in out SMS of AplusWEBs When many AplusWEBs are deployed in the field the usefulness becomes more evident All incoming SMS either correct or invalid commands as well as any other SMS messages from any mobile phones will be forwarded to this number for logging This function is in effect serves as a remote event logger Forward Number Max 15 numeric characters 1 90999650 Figure 9 4 Forward Number WARNING Never set the forward mobile phone number to be the same as the SIM card number in AplusWEB This will cause the device to send no ending SMS to itself SMS Settings This feature when enabled will send the alarm SMS repeatedly maximum of 4 times to the operation and forward mobile phones The repeat interval can be set between 2 30 minutes Repeat SMS on Alarm State If set when an alarm is triggered the SMS will be sent
20. ation page will appear This page and all other pages are designed for ease of use Explanation is provided whenever necessary Xx e Figure 8 2 Digital Input X1 Each digital alarm input has a set of variables for the user can enter Following is the description of each field that the user can configure AplusWEB has 8 digital inputs X1 X8 Description This field is for the user to provide meaning name for the point to be monitored The description can be up to 40 characters long 19 Linkwise Technology Pte Ltd AplusWEB User Manual Open This field describes the state of the input when the input voltage level is low 0 5V This is also the contact open state It can be of any wordings up to 15 characters long Examples are Alarm Normal Start Stop System reset Fault etc Close This field describes the state of the input when the input voltage level is high 8 24V This is also the contact close state It can be of any wordings up to 15 characters long Examples are Alarm Normal Start Stop System reset Fault etc Alarm state Three possible settings can be selected None Open Close This setting defines what the alarm state is The status page will show the state of the input based on the state description configured Input Config Example 1 Below is an example of defining the input state X1 as a non critical alarm Input Config Alarm state None Figure 8 3 8 5 shows Input X1 set to Alarm State None If
21. changes from Alarm to Normal state SIM Card Pin Code The user can opt to lock the SIM card to prevent unauthorized use of the SIM card To enable to pin lock feature place the SIM card on any mobile phone and use the phone function to lock the SIM card Refer to the phone manufacturer user manual for instruction On the SIM Card Pin Code field supply the same lock code as you have set using the mobile phone Place the SIM card back to AplusWEB Refer to the section on SIM card insertion for detail Sim Card Pin Code B Note Leave blank if Sim Card is not locked Figure 9 6 SMS Card Pin Lock Clear queued SMS If there is a situation of multiple alarms the alarms are stored in memory queue for the GSM modem to perform SMS ing of messages If during the process of sending SMS a power failure occurs the queue information remains in memory When power is restored AplusWEB will resume the sending of SMS The Administrator can click on the Clear button to delete the queued SMS alarms 26 Linkwise Technology Pte Ltd AplusWEB User Manual Send test SMS to Mobile Phone To test whether the unit is able to send out SMS type in the Mobile Phone number in the field and click Send to send out a test SMS Clear queued 5M5 Send test SMS to Phone Figure 9 7 Send test SMS 27 Linkwise Technology Pte Ltd AplusWEB User Manual Chapter 10 Relay Output Configuration AplusWEB has 2 relay outputs These outputs can be turn
22. e device using this option Auto Health Check This feature automatically reports to recipients the telco signal strength of AplusWEB over SMS If enabled AplusWEB will send an SMS message on the preset day and time The Enable checkbox enables the auto health check SMS to be sent at the scheduled date amp time and to the appointed operation phone group Auto Health Check Automatically check and send telco signal strength Enable Day Daily 10 00 hh mm Figure 11 8 Auto Health Check Configuration 32 Linkwise Technology Pte Ltd AplusWEB User Manual Chapter 12 Help Page AplusWEB allows a number of important functions to be accessed and controlled remotely via SMS by the listed and authorized mobile phones The three categories of users Operation Forward and Authorizer have specific rights in the use of various remote control functions This page summarizes each function and rights Two important arguments are used in conjunction with the action commands Is a query and is a set argument Example ROP is to query the device Read Operation Phone W OP is to write to the device Write Operation Phone Note If a command sent to AplusWEB does not match the required format or is invalid AplusWEB will not respond to the querying mobile phone and no action is taken by it Similarly if any unauthorized mobile phones try to query a status or to do a set command it will also not respo
23. er Manual NTP server To enable time synchronize with NTP server Set the Host or IP address of the NTP server to be used Select the GMT from the drop down box and check the Enable checkbox The NTP will synchronize the time with the server that has less number of the stratum Synchronise with NTP server Time Zone cur 08 00 M Enable Figure 11 4 NTP Server Change Administrator Password This feature enables the administrator to change the username and password for the Administrator account Ensure that the setting is recorded and kept in a safe place Entering wrong username and password will prevent access to AplusWEB menu Contact your distributor if this happens This login account for a user does have full administrator privileges The default username and password for this user account is admin To change the Administrator password inside this field under Current Password type the current administrator password followed by a new password in both New Password and Verify Password fields then click on the Apply button current Password Verity Password Figure 11 5 Change Administrator Password Change Guest Password This feature enables the administrator to change the password for the Guest account The Guest account does not have administrator privileges Guest user is not allowed to make any changes in configuration or view all the administrative pages The default username and password for this user acco
24. er Manual Output control M SMS or locally On Off relay outputs through web browser Analog Input No of Analog points eds RASA 2 analog inputs 4 20 MmA inputs 4 20mA Configurable input description scaling trigger delay high low alarm Configuration points Remote Management Add Edit Delete mobile phone groups repeat time Query Operational Authorizer Forwarder mobile phone numbers Remote Command Query health check Query input output analog status On Off output equipments devices Acknowledgements SMS Alert 8 mobile phone numbers for Operation Group 2 mobile phones numbers for Authorized Group Phone Groups c 1 mobile phone number for Forward Number d dnte HH HL International Phone Number format and support Auto dnte HH HL Digital inputs relay outputs amp analog input 2 messages per input Configurable SMS Message One for On State and Off State Triggering Auto Health Check Programmable daily weekly system health check Time Stamp SMS sent amp received with time stamps Table 3 1 Product Features a eS 8 mobile phone numbers for Operation Group ee Package contents 1 1 unit of AplusWEB Power Supply 12 ways pluggable screw terminal 1 piece 8 ways pluggable screw terminal 1 piece GSM antenna SMA mount Ethernet Cross Cable CD containing product brochure application utility user manual poc he aaa
25. ere it can fall into such power lines or circuits When installing an outside antenna system extreme care should be taken to keep from touching such power lines or circuits as contact with them might be fatal e Overloading Do not overload wall outlets and extension cords as this can result in a risk of fire or electric shock e Object and Liquid Entry Never push objects of any kind into this device through openings as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock Be careful not to spill liquid of any kind onto the device Linkwise Technology Pte Ltd AplusWEB User Manual e Servicing Do not attempt to service this device yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified personnel Opening the cover may void your warranty e Do not install the device in the following locations as this can cause a fire or electric shock x Hot locations x Close to a fire x Very humid or dusty locations x Locations exposed to direct sunlight x Locations exposed to salt spray x Close to flammable solvents alcohol thinners etc e If any of the following occurs immediately switch the device OFF unplug it from the main power supply and contact your distributor or agent x The device emits any smoke heat abnormal noise or unusual odour x metal object falls into the device x The device is damaged in some wa
26. es phone groups etc are done via the Ethernet port Alarm Triggering An alarm event happens when any one or more digital and analog input changes state AplusWEB continuously monitor the input for these events When an alarm event occurs it picks up information from the configuration memory and performs the necessary SMS actions In such an event all mobile phone numbers stored in the memory will receive the SMS alert The format of the message is Date Time Device ID Input description Status Date Time The time of alarm event occurs The real time clock within AplusWEB provides the time stamping information Device ID The identity assigned by the user during software configuration The user defines input description and status during software configuration Each digital input will have its own unique input description name and status text Example of an SMS alarm message 29 12 12 14 39 AW920 Power Supply in Basement 1 Fault Up to 8 mobile phones can be alerted to This group of phone numbers is known as operation phones Additionally if a forward phone number is specified it will receive the alarm notification as well Please refer to the following pages on how to configure AplusWEB Configuring the Device AplusWEB is a web based product Using any web browser on the PC the user with administrative rights can access all the user configuration pages IP Address oetup the device with the RJ45 Ethern
27. et cable plugged onto the RJ45 socket of the device on one end and the other either to the network Ethernet switch or directly to a PC When connecting to a PC use a cross Ethernet cable AplusWEB has static IP capability Its default IP address is 192 168 1 30 14 Linkwise Technology Pte Ltd AplusWEB User Manual Standalone Configuration Static IP In a standalone environment with one AplusWEB directly connected to a standalone PC requires a crossover Ethernet cable which is supplied with the AplusWEB unit In order for the PC and the AplusWEB to connect to each other the PC must be manually set to a static IP address that is within the same subnet as the AplusWEB Given the default configuration of IP address 192 168 1 30 and 255 255 255 0 for the subnet mask a suitable IP addresses for the PC would be 192 168 1 1 or any other IP address other then 192 168 1 30 Warning Remember that yu SHOULD NOT use the same IP address 192 168 1 30 for your PC and AplusWEB and both PC and AplusWEB need to be within the same subnet If you are unsure of how to set static IP address for your PC please consult your PC operating system s documentation for details Accessing AplusWEB Web Pages Once the IP address of the PC has been configured the user can setup the device using the PC browser The PC IP address must be in the same network range as the device To learn more about IP address and subnet mask visit www learntosubnet com Open t
28. et to 30 degrees and the room temperature varies between 27 and 30 you could be faced with a very large number of SMS and events logged In the example below the Hysteresis is set to 4 then the transmitter would have to drop from 30 to 26 before the status would change from High Alarm back to normal Warning and Error Messages If the user input any values that are out of range AplusWEB will prompt an error The user must re enter the correct value 22 Linkwise Technology Pte Ltd AplusWEB User Manual Analog Config Temperature High Alarm Normal Range Server Room Temp Hormal 23 0 degree Figure 8 11 Analog Input A1 High Alarm Figure 8 12 8 13 shows Analog Input A1 in High Temperature Stage When temperature rises to 30 0 degree SMS will be send out stating Server Room Temp High Alarm When temperature falls to 26 0 degree SMS will be sent out stating Server Room Temp Normal Server Room Temp High Alarm 30 0 dearee Figure 8 12 Status Analog Input A1 Alarm State Server Room Temp Hormal 26 0 degree Figure 8 13 Status Analog Input A1 Normal State Low Alarm Figure 8 14 8 15 shows Analog Input A1 in Low Temperature Stage When temperature falls to 16 0 degree SMS will be sent out stating Server Room Temp Low Alarm When temperature rises to 20 0 degree SMS will be sent out stating Server Room Temp Normal Server Room Temp Low Alarm 18 0 degree Figure 8 14 Status Analog Input A1 Low Alarm Server
29. f installed network components select Internet Protocol Version 4 TCP IPv4 and then click the Properties button a Intel R 82562V 2 10 100 Network Connection Configure This connection uses the following items Client for Microsoft Networks dallaos Packet Scheduler dial File and Printer Sharing for Microsoft Networks Intemet Protocol Version 6 TCP IPv amp EE intemet Protocol Version 4 TCP IPv4 wi Link Layer Topology Discovery Mapper 1 0 Driver wi Link Layer Topology Discovery Responder Properties es Control Protocol Intemet Protocol The default wide area network protocol that provides communication across diverse interconnected networks Figure 15 11 Internet Protocol Version 4 TCP IPv4 Step 6 Select Use the following IP address and in the P address field enter a suitable IP address for your PC such as 192 168 1 100 This is your PC s static IP address In the Subnet mask field enter 43 Linkwise Technology Pte Ltd AplusWEB User Manual 255 255 255 0 Leave the Default gateway field blank You may leave the Obtain DNS server address automatically as it is Internet Protocol Version 4 TCP IPv4 Properties o Figure 15 12 IP Configuration Example Step 7 Click the subsequent OK buttons to accept the settings and to close the windows until you get back to the desktop Your IP settings are now correct 44 Linkwise Technology Pte Ltd AplusWEB
30. he web browser application on your PC It can be Internet Explorer version 6 and above Firefox oafari Netscape Opera or any other standard web browser Open your web browser at the address bar type in the IP address of AplusWEB and press Enter the Login Page is then loaded 15 Linkwise Technology Pte Ltd AplusWEB User Manual Chapter 6 Login Page Enter the User Name and Password on the text box The default user name for administrator is admin Password admin Guest user login user name is guest Password guest Administrator user can change the password in the Administration page AplusWEB Model AW 920 Model AW 920 User Name Password L Copyright 2011 by Linkwise Technology Pte Ltd All Rights Reserved Figure 6 1 Login Page Follow through the various pages to setup the parameters according to the user requirement 16 Linkwise Technology Pte Ltd AplusWEB User Manual Chapter 7 Status Page Once the user successfully logs in the status page appears In a new un configured unit the status page shows all preset information about the input and output states AplusWEB excosox Model AW 920 MENU Device ID AW920 AplusWEB GSM Network in Administrator IP Address 192 168 1 87 Static Signal Strength 12 1 Volts IO Config pem Group a Administration Figure 7 1 Status Page The left hand side of the page has a set of menu
31. horized personnel can perform the change from anywhere using their mobile phone Where there are many installed sites this becomes very efficient Remotely add change or clear any setting of repeat time interval in AplusWEB memory Flexibility to change clear the repeat SMS once users are familiar with the monitored site and wish to stop receiving repeat SMS Or a new site that you wish to receive the repeat SMS All these control are just as simple by using the above remote command from anywhere using you mobile phone 36 Linkwise Technology Pte Ltd AplusWEB User Manual Chapter 13 About Page The page shows the product information of the AplusWEB Product Name Model Serial Number Mac Address Firmware and the network setting of the device Product Details Product Name AplusWEB Device ID AW920 AplusWEB Model AW 920 Serial Number FB1001 Mac Address 00 10 96 00 00 30 Firmware Version v2 0 8 IP Address 192 168 1 87 Static subnet Mask 293 209 299 Gateway 192 168 1 1 Modem IMEI 012207001991006 Figure 13 1 About Page Chapter 14 Logoff Page This page quits and logs out the menu function Once the user logs out the usual User Name and Password is required to access the Menus Always remember to logout at the end of each session to prevent any unauthorized user to access the pages unless user needs to monitor the device and equipments at all times Click Yes to logout or No to return to previous page Are you s
32. in the normal range High Alarm when reading rises the preset High Alarm and Low Alarm when reading falls to the preset Low Alarm Value This field displays the analog input 4 20mA transmitter reading 18 Linkwise Technology Pte Ltd AplusWEB User Manual Chapter 8 IO Config Page This page shows the template for defining input description as well as the status Each input can assume 2 statuses one is when the input contact is closed and another when the input contact opens The administrator is free to define the labels according to the device characteristics AplusWEB TET PICOBOX MENU Status i 1 Input X1 Open Close e Phone Group x2 Input X2 Open Close e Administration m EG 7 e 6 About i X4 Input X4 Open Close e Help _ _ X5 Input X5 Open Close e e Logoff ey u X6 Input X6 Open Close e 7 Input X7 Open Close e x8 Input X8 Y Output Y1 Output Y2 EU DI G8 el ee m m A2 Analog input A2 sds oo 100 0 2 0 0 0 40 60 Apply Cance yright 2011 by Linkwise Technology Pte Ltd All Rights Reserved Figure 8 1 Input Configurations Click on the IO Config button on the Menu buttons The Input configur
33. larm controller the device can monitor up to 8 digital inputs from different equipments interfaced to it It accepts dry contact volt free inputs The user can define each input according to the type of equipment the inputs are interfaced to When the input changes state from normal to alarm or vice versa SMS are sent out to recipients mobile phone AplusWEB has powerful features and is flexible allowing users to decide how the messages will be sent It also has an analog input allowing the user to interface to any industrial standard 4 20mA transmitter sensor Some examples are temperature humidity flow current power pressure and so on Later part of this manual will describe each feature of the product in detail Linkwise Technology Pte Ltd AplusWEB User Manual Chapter 2 Safe Use of Device The following section contains important operating and maintenance servicing instructions Please read it carefully Warnings To reduce the risk of electric shock e Do not remove the cover or back of this device There are no user serviceable parts inside Refer servicing to qualified service personnel e Do not expose this device to rain or moisture To reduce the risk of electric shock and electromagnetic interference use only recommended accessories Note The serial number of this device is shown on the side of the product You should record the number and other vital information here and retain this booklet as a permanent
34. mA analog input interface to any industrial standards transmitter Any such transmitters can be used with AplusWEB to monitor temperature humidity pressure current voltage power etc Setting up is very easy Refer to the transmitter manufacturer specification for help in inputting the fields in this page 21 Linkwise Technology Pte Ltd AplusWEB User Manual Example of Analog Config Temperature Hysteresis _ Engineering Engineering Offset Low High Analog Bescnpsun Ma7 20 Unit value at 4mA value at 20mA M ics Value Alarm Alarm A1 Server Room Temp Degree C 0 0 70 0 2 0 0 0 16 28 E Figure 8 10 Example of Analog Input A1 Temperature Unit Input the unit for the analog input value Engineering Value at 4mA 20mA Refer to the transmitter manufacture specification Hysteresis oet the minimal change required to revert from High Low alarm state Low Alarm oet the minimum analog input Low Alarm value Low Alarm checkbox Check this box to enable Low Alarm SMS will be sent out when the Analog input state changes from Normal to Low High Alarm oet the maximum analog input High Alarm value High Alarm checkbox Check this box to enable High Alarm SMS will be sent out when the Analog input state changes from Normal to High Tips Set the Hysteresis higher to prevent the transmitter from flickering between two states For example if you set the Hysteresis at 3 degrees High Alarm is s
35. nd to that mobile phone Query Mobile Phone Numbers An authorized person can perform query and hanging of Operation Forward and Authorizer mobile phone numbers stored in the unit s memory SMS Remote SMS Sample Comment Action Command Command aS Operation euler whole group leave N number s Ho o Ho o mop empty Query Forward number Query Ge N apt apt N Authorizer phone 1 3 Authorizer Query whole group leave N numbers Table 12 1 Query Mobile Phone Numbers Phone Management An authorized person can remotely phone manage the Operation Forward and Authorizer mobile phone numbers stored in the units memory The Authorizers are allowed to perform Addition Replacement and Deletion of mobile phone numbers remotely using SMS commands SMS Remote Sample SEES oras Add Delete wo op wop N phn number N Operation phone 1 8 Replace 1 98765432 Delete number leave Operation wop N wop 1 phn_number empty number wf Add Delete wfp N phn number d N Forward phone 1 1 98765432 Replace Delete number leave no yes Forward wfp N wfp 1 phn_number empty 33 Linkwise Technology Pte Ltd AplusWEB User Manual we Add Delete wap wap N phn_number N Authorizer phone 1 3 Replace 1 98765432 Delete number leave no yes Authorizer wap N wap 1 phn_number empty number Table 12 2 Phone Management Query IO amp system status Operation and authorized users can
36. ntrol Panel 38 Linkwise Technology Pte Ltd AplusWEB User Manual Step 3 You will see the Network settings window Figure 15 3 Select the correct TCP IP gt Ethernet Adapter Ethernet card configuration The figure below only shows an example the correct one in your situation will be the TCP IP to Ethernet setting for the Ethernet card that is connected to the AplusWEB Select the correct adapter and click the Properties button Hetwork Configuration Identification Access Control The following network components installed zisl Dial Up Adapter JA xiream CreditCard Ethernet Adapter 10 100 a NDISWAN gt Creative DSL DEF410 File and printer sharing for Microsoft Networks Remove Properties Primary Network Logon Chent For Micragaft Hetwork s File and Print Sharing Description ts the protocol you use ta connect to the Internet and wide area networks OF Cancel Figure 15 3 Network Settings Step 4 You will then see the TCP IP settings window as shown in Figure 15 4 Enter the fixed IP address for the PC If you are keeping the default IP settings for the AplusWEB and are using it in a standalone environment a suitable setting for the PC is an IP address of 192 168 1 100 and a subnet mask of 255 255 255 0 Click OK to close the window and accept the changes 39 Linkwise Technology Pte Ltd AplusWEB User Manual TCP IP Properties
37. on off or pulse remotely via SMS commands It can also be controlled from locally in or remotely from the web page access Status page Rey Description Mas 15 characters Y 1 Y2 Output Y2 Figure 10 1 Relay Output Configuration The 2 relay outputs are Y1 and Y2 The user can create a description for each input of up to 20 characters long The two output description should not be identical Each Relay output has its own sets of settings Remote Control Output using SMS This feature enables user to switch any of the 2 outputs on contacts close off contacts open by sending the appropriate Action SMS message to the AplusWEB unit The AplusWEB is non case sensitive to the received Action SMS messages After performing the required action AplusWEB replies to the sender with the corresponding Reply SMS message In the example shown in Figure 10 3 to switch Relay 1 on i e to close the contacts send an SMS fon Buzzer message to AplusWEB Upon closing the Relay 1 contacts AplusWEB will reply with the SMS message 29 12 20011 15 05 AW920 Buzzer ON Triggered To prevent ambiguities each Action SMS message must be unique Remember that the messages are case insensitive Another way to control output relay without going through SMS is by clicking on the output control section in the Status page 28 Linkwise Technology Pte Ltd AplusWEB User Manual Status Completed Input Output and Analog Input Example
38. or navigation buttons On the right side is the page of the currently selected choice Click on any of the buttons will bring the respective pages out MENU IO Config Phone Group TM Administration About TM Help Figure 7 2 Menu or Navigation Buttons The top of the page contains the device information like Device ID IP address GSM Network name Signal Strength Login user and Date time Device ID AW920 AplusWEB GSM Network STARHUB Login Administrator Date 08 12 2011 IP Address 192 168 1 87 Static Signal Strength 74 Battery 12 0 Volts Time 16 59 09 Figure 7 3 Device Information 17 Linkwise Technology Pte Ltd AplusWEB User Manual In a configured unit the status of the inputs outputs and analog channels are displayed Any change in the digital input output and analog state are automatically updated live Description These fields display what has been typed into the description field of digital input analog input and relay output on the IO configuration pages Status This field displays the status of each equipment connected to AplusWEB Input status This field will display what has been typed into the open close fields of digital input IO Config page Output status This field will display either ON the contact of the output is close or OFF contact of the output is opened Analog status This field will display Normal when the reading is with
39. record of your purchase Model No Serial No Date of Purchase Dealer Purchased from Dealer Address Dealer Telephone No Important Safety Instructions In these safety instructions the word device refers to AplusWEB and all its accessories Read Instructions Read all the safety and operating instructions before operating the device e Retain Instructions Save the safety and operating instructions for future reference e Heed Warnings Heed all warnings on the device and in the operating instructions e Follow Instructions Follow all operating and maintenance instructions e Cleaning Unplug this device from the wall outlet before cleaning Wipe the device with a clean soft cloth If necessary put a cloth in diluted neutral detergent and wring it well before wiping the device with it Finally clean the device with a clean dry cloth Do not use benzene thinner or other volatile Linkwise Technology Pte Ltd AplusWEB User Manual liquids or pesticides as they may damage the product s finishing When using chemically treated cleaning cloths observe their precautions accordingly e Accessories Use only accessories recommended in this manual Always use specified connection cables Be careful to connect devices correctly e Water and Moisture Hazard of electric shock Do not use the device near water or in rainy or moist situations e Ambient Temperature Do not put this device near
40. rt the card push the SIM card on to the slot SIM card facing upwards as shown in figure 4 3 Do this using a small flat tool Example slot head screwdriver Slide it in all the way until you feel it touching the end To remove gently press on the SIM card using a small slot head screwdriver Step 3 Attach the antenna provided in the package onto the antenna socket If an external antenna is required contact your distributor for more information on external high gain antenna Step 4 Wire the input output connection between the equipment and AplusWEB using the pluggable screw terminal provided Push the SIM card to this socket SIM card facing upwards Figure 4 3 SIM card Socket DC INPUT Power to AplusWEB is supplied from the 12VDC power adapter via the DC jack input If using user supplied power supply observe voltage polarity and voltage level AplusWEB operates on 12VDC input but can accept supply voltage up to 18VDC Do not exceed the recommended input voltage exceeding which will damage the AplusWEB Ethernet The RJ 45 connector connects AplusWEB to the computer or network using Cat5 UTP cable For connection to a single PC use the cross Ethernet cable supplied with the unit A hub or Ethernet switch is not necessary for direct AplusWEB to PC interface AplusWEB can be used as a standalone system or connected to the local area network LAN A LAN connection gives greater flexibility as well as enabling Apl
41. unt is guest To change the Guest password type a new password in both New Password and Verify Password fields then click on the Apply button New Password Verify Password Figure 11 6 Change Guest Password 3l Linkwise Technology Pte Ltd AplusWEB User Manual Network Configuration This setting is self explanatory Care is to be exercised in setting the IP address and subnet mask values Incorrect IP address subnet mask setting will render AplusWEB inaccessible from the network Invalid IP Subnet range will also cause AplusWEB to be inaccessible from the network AplusWEB do have error trapping and will warn of any invalid settings If for some reason the trapping misses and the invalid values are accepted by the unit and cause network connection difficulties contact your distributor for assistance Network Configuration IP Address 192 168 1 30 Subnet Mask 255 255 255 0 Gateway 192 168 1 1 Figure 11 7 Network Configuration Dynamic IP Mode By default AplusWEB s IP address is 192 168 1 30 and the default subnet mask is 255 255 255 0 This means the IP address of your PC may be set in the range 192 168 1 1 to 192 168 1 254 inclusive but obviously excluding 192 168 1 30 which is the address for the AplusWEB IP Address You can change the IP address of AplusWEB using this option Enter the new IP address Subnet Mask Set the subnet mask of the device using this option Gateway Set the default gateway of th
42. ure you want to logoff Yes Mo Figure 14 1 Logoff Page 37 Linkwise Technology Pte Ltd AplusWEB User Manual Appendix Setting Static IP Addresses Upon powering up AplusWEB it will search for the presence of a DHCP server If the DHCP server present it will accept the IP address assigned by the DHCP server otherwise it will assume a default IP address of 192 168 1 30 That is the default IP address is 192 168 1 30 and the default subnet mask is 255 255 255 0 This means the IP address of your PC may be set in the range 192 168 1 1 to 192 168 1 254 inclusive but obviously excluding 192 168 1 30 which is the address for the AplusWEB unit For the examples below we are using the address 192 168 1 100 for the PC Setting a Static IP Address for Windows 98 Step 1 Click on the Start button and select Control Panel Figure 15 1 Favorites d Documents d A Control Panel 5 Printers A Taskbar amp Start Menu je IT zi w 2 Folder 0 Hel e Hep Active Desktop 4 By windows Update Log Shut Down Figure 15 1 Start Button Step 2 In the Control Panel window double click the Network icon Figure 15 2 File Edit View Go Favorites Address a Internet Keyboard Magic ave Microsoft Mall Options 30 Contig Postottice y x Modems Mouse Multimedia ODBC Data Sources 32bit L Figure 15 2 Co
43. usWEB to work with other networking devices 11 Linkwise Technology Pte Ltd AplusWEB User Manual Antenna This SMA connector interfaces the external antenna to the internal GSM modem of AplusWEB Choose suitable antenna for your installation The SMA mount Antenna supplied as standard accessory is the unity gain antenna This antenna is suitable for most installation If the location has low GSM signal strength use high gain antenna or outdoor type Check with your distributor for suitable antenna alternatives FD Factory Default This button allows user to reset the password and IP address to factory default To reset Administrator Guest user password 1 Power Off the device 2 Push and Hold FD button and power on the device Power On device 3 Continue to hold the button for 8 seconds or more 4 Release the blunt tool To reset the IP address 1 Attach the cross cable to PC or Ethernet switch Power ON the device 3 Push and Hold FD button for 8 seconds with a blunt tool Release the blunt tool Note To prevent unauthorized reset the device should be installed in ABS housing with lock 12 Linkwise Technology Pte Ltd AplusWEB User Manual Interfacing to Equipments Figure 4 4 shows how alarm inputs are wired to AplusWEB Up to 8 dry contacts can be monitored simultaneously The contacts shown are either relay contact or switches from within the equipment Cabling distance of up to 50 meters between the equipment and
44. y Do not continue to use the device as this can cause a fire or electric shock e Please observe the following when using the device Failure to do so can result in a fire or electric shock x Do not use flammable sprays near the device x Do not subject the device to strong impact Linkwise Technology Pte Ltd AplusWEB User Manual Chapter 3 Product Overview The AplusWEB is a standalone device built around a 32 bit microcontroller It has a built in dual band GSM modem along with associated circuitries like switching power supply optically coupled digital inputs relay outputs indicators etc AplusWEB is IP based Internet Protocol comes with user friendly web user interface and powerful feature set Features Table 3 1 shows the product features of AplusWEB Operating Voltage 9 to 18VDC 2W max power consumption GSM modem Quad Band GSM 850 900 1800 1900 Mhz 70 L x 110 H x 60 D mm Industrial standard ABS housing with Din rail mounting Pluggable ountin i 5mm screw terminal block HTTP Hyper Text Transfer Protocol Digital Input No of Input points 8 optically coupled dry contacts digital inputs opto isolate Independent configuration of input description open close status Configuration n description Relay Output No of Output points 2 relay outputs contact rated at 30VDC 2A Configuration User defined output description Linkwise Technology Pte Ltd AplusWEB Us

Download Pdf Manuals

image

Related Search

Related Contents

Istruzioni d`Uso - Amazon Web Services  area lenguaje  MANUAL DE USUARIO  none 6013-167 Instructions / Assembly  Família de servidores SGI™ 1400 Guia do usuário  Quick Reference Guide to PharmaCare Claims for Insulin Pump  TABLEAU ÉLECTRONIQUE LRX 2035 Compact  MANUAL DE INSTALAÇÃO Apache ModSSL  

Copyright © All rights reserved.
Failed to retrieve file