Home
CC-Link IE Controller Network Interface Board User`s Manual
Contents
1. EN61000 4 3 Radiated electromagnetic field immunity AM modulation Immunity test in which a field is irradiated to the product 10 V m 26 1000 MHz 80 AM modulation 1 kHz EN61000 4 6 Conducted disturbances immunity mmunity test in which a high requency noise is applied to a power ine and signal line EN61000 4 5 Surge immunity Immunity test in which a lightning surge is applied to a power line and signal line 1 Quasi peak value Mean Mean value 11 Power line 2 kV CM 1 kV DM Data communication shielded 1 kV CM Digital Analog I O shielded 1 kV CM 5 1 2 Installing devices in the control panel Installing devices in the control panel has a considerable effect not only securing safety but also shielding the noise generated from the personal computer in the control panel 1 Control panel a Use a conductive control panel b When attaching the control panel s top plate or base plate mask painting and weld so that good surface contact can be made between the panel and plate c To ensure good electrical contact with the control panel mask the paint on the installation bolts of the inner plate in the control panel so that contact between surfaces can be ensured over the widest possible area d Ground the control panel with a thick wire so that a low impedance connection to ground can be ensured even at high freq
2. Use a specified tool for crimping of the cable and contacting pin Imperfect crimping may cause a malfunction Verify the pin out and fully insert the crimped contacting pin into the connector Imperfect insertion may cause a failure or malfunction A 3 Wiring Precautions A CAUTION Insert the wired external power supply cable into the external power supply cable connector until a click is heard Imperfect insertion may cause a failure or malfunction Keep the external power supply cable away from the main circuit cable power cables and or the load cables for any other than programmable controllers Ensure a distance of 100 mm 3 94 in between them Failure to do so may result in a malfunction due to noise surge or induction Always ground the personal computer to the protective ground conductor Failure to do so may cause a malfunction Disposal Precautions A CAUTION When disposing of this product treat it as industrial waste A 4 Revisions Print Date Apr 2007 The manual number is given on the bottom right of the cover Manual Number 0800386 Revision First edition Oct 2007 IB NA 0800386 B Correction Chapter 5 Section 7 2 Chapter 8 Jan 2008 IB NA 0800386 C Correction SAFETY PRECAUTIONS Manual Chapter 1 Chapter 2 Chapter 3 Chapter 4 Chapter 5 Chapter 6 Chapter 7 Sep 2008 IB
3. Controller Networl This manual explains the system configuration performance specification functions handling and wiring instructions and troubleshooting of the CC Link IE Controller network system Sold separate Manual Number Model Code SH 080668ENG 13 16 CC Link IE Controller Network Interface Board User s Manual For SW1DNC MNETG B This manual explains the system configuration software package installation and uninstallation operating method for utilities accessible ranges and devices and troubleshooting of the CC Link IE Controller Network board Sold separately A 7 SH 080691ENG 13JZ02 1 OVERVIEW This manual explains the handling of the Q80BD J71GP21 S SX CC Link IE Controller Network interface board hereinafter referred to as CC Link IE Controller Network board The CC Link IE Controller Network board can be used as a control station or normal station in the CC Link IE Controller network system The packing list of the CC Link IE Controller Network board is given below Quantity Q80BD J71GP21 SX Q80BD J71GP21S SX Q80BD J71GP21 SX CC Link IE Controller Network interface board Q80BD J71GP21S SX CC Link IE Controller Network interface board Connector set for external power supply cable CC Link IE Controller Network Interface Board User s Manual Hardware SW1DNC MNETG B CC Link IE Controller Network software package CD Sof
4. 02 Mitsubishi Electric Building Singapore 159943 Tel 65 6473 2308 Thailand F A Tech Co Ltd 898 28 29 30 S V City Building Office Italy Mitsubishi Electric Europe B V Italian Branch Centro Dir Colleoni Pal Perseo Ingr 2 Via Paracelso 12 20041 Agrate B Milano Italy Tel 39 039 6053344 Manin ane 5 Mitsubishi Electric Europe B V Spanish Bangkok TU Branch Tel 66 2 682 6522 Carretera de Rubi 76 80 08190 Sant Cugat del Valles Barcelona Spain Indonesia Autoteknindo SUMBER MAKMUR JI Muara Karang Selatan Block a Utara No 1 Kav No 11 Kawasan Industri Tel 34 93 565 3131 Jakarta Utara 14440 France Mitsubishi Electric Europe B V French 181 362 21 563 0833 TY Branch i India Messung Systems Put Ltd 25 Boulevard des Bouvets F 92741 Electronic Sadan NO 111 Unit No15 Nanterre Cedex France M LD C BHOSARI PUNE 411026 India TEL 33 1 5568 5568 Tel 91 20 712 2807 South Africa Circuit Breaker Industries LTD Australia Mitsubishi Electric Australia Pty Ltd Tripswitch Drive Elandsfontein Gauteng 348 Victoria Road PostalBag No 2 South Africa Rydalmere N S W 2116 Australia Tel 27 11 928 2000 Tel 61 2 9684 7777 AMMITSUBISHI ELECTRIC CORPORATION HEAD OFFICE 1 8 12 OFFICE TOWER Z 14F HARUMI CHUO KU 104 6212 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 HIGASHI KU NAGOYA JAPAN When exported from Japan this manual does not require application
5. L 815 ex ted Sel 4 315 S x o 5 o 5 1 f 18 5 0 73 Unit mm inch 24 2 Q80BD J71GP21S SX 174 5 6 87 kN em 181 7 13 168 6 61 7 tH o em 0 5 zl TT L e N Qu e x i 2 5 e RISE Ez JR 3 fl Y Unit mm inch Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and other countries Ethernet is a registered trademark of Xerox co Itd in the United States Other company names and product names used in this document are trademarks or registered trademarks of respective companies 25 Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties A For safe use This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life Before using the product for special purposes such as nuclear power electric power aerospace medicin
6. Mitsubishi electric system amp service Co Ltd b When connecting an optical fiber cable to the Q80BD J71GP21 SX and Q80BD J71GP21S SX the cable bend radius is restricted For details check the specifications of the cable used c When laying the optical fiber cables do not touch the fiber cores of the cable side and board side connectors and protect them from dirt and dust If oil from the hand dirt or dust is attached to the core it can increase transmission loss causing a problem in data link d When connecting or disconnecting an optical fiber cable hold the connector part of the cable e Make a full connection between the cable side and board side connectors until a click can be heard f When installing the Q80BD J71GP21 SX or Q80BD J71GP21S SX to the personal computer secure a space of around 10 mm 0 39 in to the right and left of the optical connector Depending on the adjacent boards and installing slot position connecting disconnecting the optical cable may be difficult In this case use the following dedicated tool SCT SLM Mitsubishi electric system amp service Co Ltd nz CC Link IE Controller Network board all Board side connector NT Cable side connector Connector hook amp 2 7 18 6 2 External power supply cable This section explains the method for connecting external power supply cable to the Q80BD J71GP21S SX 1 Parts and tools required for external power
7. this manual Using it in an environment that does not meet the general specifications may result in an electric shock fire malfunction damage to or deterioration of the product Always ground the personal computer to the protective ground conductor Failure to do so may cause a malfunction 4 PART NAMES This section explains each part name and setting of the CC Link IE Controller Network board 1 Q80BD J71GP21 SX o L 8 42 2 ee L ler n N LJ 2 Q80BD J71GP21S SX 4 3 1 S 1 Jf f Description Indicates the operating status of the CC Link IE Controller Network board The display format has three types normal mode error mode and channel number confirmation 1 Normal mode When the RUN LED is OFF or ON the LED display becomes normal mode If a communication error occurs in the mode determine the error in Select station network device status display on the CC Link IE Controller Network diagnostics result screen of the CC IE Control utility For the Select station network device status display refer to CC Link IE Controller Network Interface Board User s Manual For SW1DNC MNETG B LED name Status Description OFF A WDT error occurred or the board RUN is being reset ON In normal operation Indicator LED SD OFF Data has not been sent ON During data transmission OF Data has
8. MITSUBISHI CC Link IE Controller Network Interface Board User s Manual Hardware Q80BD J71GP21 SX Q80BD J71GP21S SX Thank you for purchasing the Mitsubishi program logic controller MELSEC Q series Prior to use please read this and relevant manuals thorougly to fully understand the product MODEL MNETG B SW1 H MELSEC MODEL Mitsubishi DO CODE 13 2 Controller IB NA 0800386 D 0809 MEE 2007 MITSUBISHI ELECTRIC CORPORATION SAFETY PRECAUTIONS 6 Be sure to read these instructions before using the product Before using this product read this manual and the relevant manuals introduced in this manual carefully and handle the product correctly with full attention to safety Note that these precautions apply only to this product Refer to the user s manual of your CPU module for safety precautions on programmable controller systems In this manual the safety instructions are ranked as DANGER and CAUTION Indicates that incorrect handling may cause Y V DANGER hazardous conditions resulting in death or severe i injury Indicates that incorrect handling may cause A CAUTION hazardous conditions resulting in minor or moderate 1 injury or property damage Note that failure to observe the AN CAUTION level instructions may also lead to serious results depending on the circumstances Be sure to observe the instructions of both levels to ensur
9. NA 0800386 D Correction Chapter 2 This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual 2007 MITSUBISHI ELECTRIC CORPORATION A 5 CONTENTS Ete OVERVIEW PERFORMANCE SPECIFICATIONS HANDLING PART NAMES EMC AND LOW VOLTAGE DIRECTIVE WIRING INSTALLING SOFTWARE PACKAGES 3 1 Handling precationis ae aA e a 4 3 2 Installation 6 5 1 Requirements for conformance to EMC Directive 10 5 1 1 Standards applicable to the EMC Directive 5 1 2 Installing devices in the control panel 5 1 3 Noise filter power supply line filter 5 2 Requirements for conformance to Low Voltage Directive 6 1 Optical fiber cable 6 2 External power supply cable essen 7 1 Installation procedures 7 2 Icons to be Registered EXTERNAL DIMENSIONS 1 triti i en ibn etnies tet i itae sated 24 A 6 Manual The following is the manual relevant to this product Please purchase it if necessary Relevant Manuals Manual Name MELSECNET G Network System Reference Manual
10. OFF External power supply is not E E PW supplied ON External power supply is being supplied External power supply LED Connector for connecting external power supply cable The cable terminal is as shown below External power Board top supply cable connector 5 EMC AND LOW VOLTAGE DIRECTIVE For the products sold in European countries the conformance to the EMC Directive which is one of the European Directives has been a legal obligation since 1996 Also conformance to the Low Voltage Directive another European Directive has been a legal obligation since 1997 Manufacturers who recognize their products must conform to the EMC and Low Voltage Directives are required to declare that their products conform to these Directives and put a CE mark on their products 5 1 Requirements for conformance to EMC Directive The EMC Directive specifies that products placed on the market must be so constructed that they do not cause excessive electromagnetic interference emissions and are not unduly affected by electromagnetic interference immunity The applicable products are requested to meet these requirements The sections 5 1 1 through 5 1 3 summarize the precautions on conformance to the EMC Directive of the machinery constructed using the CC Link IE Controller Network board The details of these precautions has been pr
11. contains a large amount of noise and thus short wiring prevents from functioning as an antenna Twist the ground cable leading to the ground point with the power supply cable By twisting it with the ground cable the noise leaking from the power supply cable may be grounded at a higher rate However twisting the power supply cable with the ground cable may not be necessary if a noise filter is installed on the power supply cable 5 1 3 Noise filter power supply line filter A noise filter is a component which has an effect on conducted noise It is not required to fit the noise filter to the power supply line but fitting it can further suppress noise The noise filter has the effect of reducing conducted noise of 10MHz or less The precautions required when installing a noise filter are described below 1 Do not bundle the wires on the input side and output side of the noise filter When they are bundled the output side noise will induct into the input side wires Input sid Input sid power Supply side power supply side Introduction Filter Filter Output side Output side device side device side a The noise will induct into input side when b Separate the input and output wires the input and output wires are bundled 2 Ground the ground terminal of the noise filter to the control panel using as short wiring as possible about 10 cm 3 94 in R
12. e or passenger movement vehicles consult with Mitsubishi This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel Country Region Sales office Tel U S A Mitsubishi Electric Automation Inc Hong Kong Ryoden Automation Ltd 500 Corporate Woods Parkway Vernon 10th Floor Manulife Tower 169 Electric Hills IL 60061 Road North Point HongKong Tel 1 847 478 2100 Tel 852 2887 8870 Brazil MELCO TEC Rep Com e Assessoria China Ryoden Automation Shanghai Ltd Tecnica Ltda 3F Block5 Building Automation Rua Correia Dias 184 Instrumentation Plaza 103 Cao Bao Rd Edificio Paraiso Trade Center 8 andar Shanghai 200233 China Paraiso Sao Paulo SP Brazil Tel 86 21 6120 0808 Tel 55 11 5908 8331 Taiwan Setsuyo Enterprise Co Ltd Germany Mitsubishi Electric Europe B V German 6F No 105 Wu Kung 3rd RD Wu Ku Branch Hsiang Taipei Hsine Taiwan Gothaer Strasse 8 D 40880 Ratingen Tel 886 2 2299 2499 GERMANY Korea HAN NEUNG TECHNO CO LTD Tel 49 2102 486 0 1F Dong Seo Game Channel Bldg UK Mitsubishi Electric Europe B V UK 660 11 Deungchon dong Kangsec ku Branch Seoul Korea Travellers Lane Hatfield Herts AL10 Tel 82 2 3660 9552 8XB UK Singapore Mitsubishi Electric Asia Pte Ltd Tel 44 1707 276100 307 Alexandra Road 05 01
13. e personal safety Please store this manual in a safe place for future reference This manual must be forwarded to the end user A 1 Installation Precautions 4 DANGER Do not touch connectors while current is applied Doing so may cause an electric shock or malfunction Be sure to shut off all phases of the external power supply used by the System before installing the CC Link IE Controller Network board to or removing it from the personal computer Failure to do so may cause an electric shock or damage to the product ZA CAUTION Use the CC Link IE Controller Network board in an environment that meets the general specifications provided in this manual Using it in an environment that does not meet the general specifications may result in an electric shock fire malfunction damage to or deterioration of the product Securely insert the CC Link IE Controller Network board into the PCI bus slot following the board installation instruction of the personal computer Incorrect insertion of the CC Link IE Controller Network board may lead to a malfunction failure or drop of the board When installing the CC Link IE Controller Network board take care not to get injured by an implemented component or a surrounding member Before handling the CC Link IE Controller Network board touch a grounded metal object to discharge the static electricity from the human body Failure to do so may cause a failure or malfunction o
14. ecting external power supply cable to the board Properly insert the wired external power supply cable to the external power supply cable connector of the Q80BD J71GP21S SX until a click is heard Keep the cable away from the main circuit cable power cables and or the load cables for any other than programmable controllers Ensure a distance of 100 mm 3 94 in between them POINT Be sure to twist the external power supply cable 20 7 INSTALLING SOFTWARE PACKAGES This chapter explains about installing the software packages and icons to be registered For the uninstallation method refer to CC Link IE Controller Network Interface Board User s Manual For SW1DNC MNETG B 7 1 Installation procedures For details of the installation procedure refer to CC Link IE Controller Network Interface Board User s Manual For SW1DNC MNETG B Multi processor personal computers cannot be used because the driver does not support them For details of the operating environment refer to CC Link IE Controller Network Interface Board User s Manual For SW1DNC MNETG B Log on as a user having administrator authority Cancel all applications registered in Startup and install the driver after restarting Windows Make sure to close other applications running on Windows including resident software such as antivirus software before installation If the installation failed uninstall the software package if possible When reins
15. emarks Reference noise filters are shown below Noise filter type Maker name Rated current Rated voltage FN343 3 01 SCHAFFNER FN660 6 06 6 250 V ZHC2203 11 TDK 5 2 Requirements for conformance to Low Voltage Directive The CC Link IE Controller Network board is out of the requirement for conformance to the Low Voltage Directive since it does not use the power supply in the range of 50 to 1000V AC and 75 to 1500V DC 14 6 WIRING This section explains precautions for connecting cables to the CC Link IE Controller Network board 1 Precautions for general wiring P DANGER Be sure to shut off all phases of the external power supply used by the system before installing the CC Link IE Controller Network board or starting wiring Failure to do so may cause an electric shock damage to the product or malfunction Before applying power to operate the system after installation of the CC Link IE Controller Network board and wiring be sure to put the cover on the module Failure to do so may result in an electric shock CAUTION When disconnecting the cable from the CC Link IE Controller Network board do not pull the cable part Pulling the cable that is still connected to the CC Link IE Controller Network board may damage the board and or cable or cause a malfunction due to poor contact Prevent foreign matter such as chips or wiring debris from getting into
16. epared based on the control requirements and the applicable standards However we will not assure that the overall machinery manufactured according to these details conforms to the above mentioned directives The final decision on the method for the EMC Directive conformance and the application must be made by the manufacturer of the machinery 10 5 1 1 Standards applicable to the EMC Directive The standards applicable to the EMC Directive are listed below All test items were tested by installing each device on a personal computer bearing a CE certification logo Specification Test item EN61000 6 4 Radiated noise Test details Measures electromagnetic emissions from product Standard value 30M 230MHz 30 dB V m 30 m in measurement range 1 230 1000 37 dB V m 30 m in measurement range EN61000 6 4 Conducted noise Measures electromagnetic emissions from the product to the power ine 150k 500kHz QP 79 dB Mean 66 dB 500k 30MHz QP 73 dB Mean 60 dB EN61000 4 2 Electrostatic immunity Immunity test in which static electricity is applied to the cabinet of the equipment 4 kV Contact discharge 8 kV Aerial discharge EN61000 4 4 Electrical fast transient burst immunity EN61131 2 2003 Immunity test in which a burst noise is applied to a power ine and signal line Power line 2 kV Data communication 1 kV Digital Analog I O shielded 1 kV
17. f the CC Link IE Controller Network board Handle the CC Link IE Controller Network board in a place where static electricity will not be generated Failure to do so may cause a failure or malfunction Do not directly touch a conductive part of the CC Link IE Controller Network board Doing so may cause a failure or malfunction Fix the CC Link IE Controller Network board by tightening the board fixing screws within the specified torque range Insufficient tightening may result in a malfunction The CC Link IE Controller Network board is included in an antistatic envelope When storing or transporting it be sure to put it in the antistatic envelope Failure to do so may cause a failure or malfunction Do not disassemble or remodel the CC Link IE Controller Network board Doing so may result in a failure malfunction injuries and or a fire Do not drop or apply a strong impact to the CC Link IE Controller Network board Doing so may cause a failure or malfunction A 2 Wiring Precautions 4 DANGER Be sure to shut off all phases of the external power supply used by the system before installing the CC Link IE Controller Network board or starting wiring Failure to do so may cause an electric shock damage to the product or malfunction Before applying power to operate the system after installation of the CC Link IE Controller Network board and wiring be sure to put the cover on the module Failure to do s
18. ilure Use a specified tool for crimping of the cable and contacting pin Imperfect crimping may cause a malfunction Verify the pin out and fully insert the crimped contacting pin into the connector Imperfect insertion may cause a failure or malfunction Insert the wired external power supply cable into the external power supply cable connector until a click is heard Imperfect insertion may cause a failure or malfunction Keep the external power supply cable away from the main circuit cable power cables and or the load cables for any other than programmable controllers Ensure a distance of 100 mm 3 94 in between them Failure to do so may result in a malfunction due to noise surge or induction Place the external power suppply cables connected to the CC Link IE Controller Network board in a duct or clamp them If not dangling cables may swing or inadvertently be pulled resulting in damage to the board or cables or malfunctions due to poor contact Remarks For details of the wiring method refer to CC Link IE Controller Network Interface Board User s Manual For SW1DNC MNETG B 6 1 Optical fiber cable The following explains precautions for connecting the optical fiber cables with the Q80BD J71GP21 SX and Q80BD J71GP21S SX 1 Precautions for connection a Use the dedicated optical fiber cable shown below for the controller network system Model name maker Multi mode fiber GI QG series
19. not been received ON During data reception RUN ERR ERR a O O RD 2 Error mode When the RUN LED is flashing the LED display becomes error mode If an error occurs in the mode check the error description on the Event Viewer screen LED name Status Description Indicates the display format is in error mode ON Indicates the display format is not in OFF error mode OFF ON OFF No driver response error ON A driver response error occurred OFF No PCI bus error ON A PCI bus error occurred SD RD Flashing RUN SD RD ERR 3 Channel number confirmation mode This mode is for checking the channel No of each board The LED displays the channel No assigned to each board For details refer to CC Link IE Controller Network Interface Board User s Manual For SW1DNC MNETG B Connector for connecting optical fiber cable 1 The cable terminal is as shown below IN Reverse loop transmission IN Forward loop reception Optical fiber cable connector o OUT Forward loop transmission OUT Reverse loop reception 2 For wiring of an optical fiber cable refer to CC Link IE Controller Network Interface Board User s Manual For SW1DNC MNETG B Indicates the status of external power supply LED name Status Description
20. ns precautions for handling and installation environment of the CC Link IE Controller Network board 3 1 Handling precautions The following explains precautions for handling the CC Link IE Controller Network board 0 DANGER 9 Do not touch connectors while current is applied Doing so may cause an electric shock or malfunction Be sure to shut off all phases of the external power supply used by the system before installing the CC Link IE Controller Network board to or removing it from the personal computer Failure to do so may cause an electric shock or damage to the product N CAUTION Securely insert the CC Link IE Controller Network board into the PCI bus slot following the board installation instruction of the personal computer Incorrect insertion of the CC Link IE Controller Network board may lead to a malfunction failure or drop of the board When installing the CC Link IE Controller Network board take care not to get injured by an implemented component or a surrounding member Before handling the CC Link IE Controller Network board touch a grounded metal object to discharge the static electricity from the human body Failure to do so may cause a failure or malfunction of the CC Link IE Controller Network board Handle the CC Link IE Controller Network board in a place where static electricity will not be generated Failure to do so may cause a failure or malfunction Do not directly t
21. o may result in an electric shock A CAUTION Special skills and tools are required to connect the communication cable to the connector plug which is an exclusive product When purchasing it please consult your local Mitsubishi representative Incomplete connection can result in a short fire or malfunction Securely plug the communication cable to the connector of the CC Link IE Controller Network board Then check for any incomplete connection Poor contact may cause an erroneous input or output Place the communication cables and external power supply cable connected to the CC Link IE Controller Network board in a duct or clamp them If not dangling cables may swing or inadvertently be pulled resulting in damage to the board or cables or malfunctions due to poor cable contact When disconnecting the cable from the CC Link IE Controller Network board do not pull the cable part Pulling the cable that is still connected to the CC Link IE Controller Network board may damage the board and or cable or cause a malfunction due to poor contact Prevent foreign matter such as chips or wiring debris from getting into the personal computer Failure to do so can result in a fire failure or malfunction Verify the rated voltage and pin out and connect the external power supply cable properly Connecting a power supply with a different voltage rating imperfect cable crimping or faulty wiring may cause a fire or failure
22. ouch a conductive part of the CC Link IE Controller Network board Doing so may cause a failure or malfunction Fix the CC Link IE Controller Network board by tightening the board fixing screws within the specified torque range Insufficient tightening may result in a malfunction The CC Link IE Controller Network board is included in an antistatic envelope When storing or transporting it be sure to put it in the antistatic envelope Failure to do so may cause a failure or malfunction Do not disassemble or remodel the CC Link IE Controller Network board Doing so may result in a failure malfunction injuries and or a fire Do not drop or apply a strong impact to the CC Link IE Controller Network board Doing so may cause a failure or malfunction Prevent foreign matter such as chips or wiring debris from getting into the personal computer Failure to do so can result in a fire failure or malfunction When disposing of this product treat it as industrial waste For the tightening torque of the CC Link IE Controller Network board fixing screws refer to the manual supplied with the personal computer 5 3 2 Installation environment For installation of the personal computer in which the CC Link IE Controller Network board is installed refer to the manual for the personal computer A CAUTION Use the CC Link IE Controller Network board in an environment that meets the general specifications provided in
23. supply cable The following parts and tools are required for making external power supply cable a Connector set accessories Check that the following parts are included with the attached connector set Applicable wire sze Quantily Connector 1 178288 3 1 Contact 175218 2 AWG 20 16 3 Spare 1 b Cable Use an external power supply cable with heat resistant vinyl sheath of 0 5 to 1 25 mm AWG 20 to 16 c Tool Use the following specified crimp tools Applicable wire size 1558 1 AWG 20 16 1762956 1 Tyco Electronics 2 Making external power supply cable a Crimping a contacting pin Using a crimp tool crimp the cable and contacting pin Set the contacting pin and cable in the grooves of the crimp tool squeeze the handle and make them stick together tightly For details of the crimp refer to the instruction of the tool A strip length of the cable should be 5 to 7 mm 1 5 to 2 7 in b Check for a crimp Check if the cable including a part of the sheath is evenly crimped to the contacting pin If the cable part is crimped but not the sheath part or the cable is stuck out the cable cut or a malfunction may result Contacting pin Cable c Connecting to the connector According to the following pin out fully insert the Connector crimped cable to the connector until a click is 20 Contacting pin heard n O 24V Pin No Description 1 24V 2 24G 3 Open 3 Conn
24. talling the software package do so after uninstalling the current software package and restarting the personal computer 21 START Power OFF the personal computer Install the CC Link IE Controller Network board to the personal computer Power ON the personal computer Install SW1DNC NMETG B driver Install SW1DNC NMETG B utility END 22 7 2 Icons to be Registered After installing the software packages the icons shown below are registered in MELSEC selected from Start Program Remarks When using Windows XP Professional Windows XP Home Edition Windows Vista the following icons are registered in Start All Programs MELSEC Utility name Description CC IE Control utility Starts CC IE Control utility Device Monitor Utility Starts Device monitor utility EROS Data Link Function starts HELP for the data link function 1 Generic term for Microsoft Windows Vista Home Basic Operating System Microsoft Windows Vista Home Premium Operating System Microsoft Windows Vista Business Operating System Microsoft Windows Vista Ultimate Operating System and Microsoft Windows Vista Enterprise Operating System 23 8 EXTERNAL DIMENSIONS 1 Q80BD J71GP21 SX 174 5 6 87 J 7 181 7 13 le 168 6 61 o
25. tection by link special relays and link special registers etc Transient transmission N N communications 120 stations Control station 1 Normal station 119 Error control system RAS functions Specification Q80BD J71GP21 SX Q80BD J71GP21S SX Number of boards that can be ul installed Up to 4 Installation slot PCI bus slot Half size or PCI X bus slot Half size Occupied slots 1 slot Voltage 20 4 V to 31 2 VDC Current 0 27A Connector Connector set Accessory Applicable cable size External power Allowable 0 50 to 1 25 AWG20 16 No external power supply supply momentary power failure time 1ms level PS1 Noise voltage 500vp p Noise width 14s By the noise simulator with noise frequency 25 to 60Hz Bus width 32 bit PCI bus performance Bus frequency 33MHz Bus voltage 5V or 3 3 V DC Universal PCI compliance Noise durability 5 V DC Internal current consumption Weight 0 12 kg 0 14 kg 1 This indicates the number of CC Link IE Controller Network boards that can be installed to a personal computer not including any other boards such as MELSECNET H boards Note that it cannot exceed the number of physical PCI slots of the personal computer 2 Use the power complies with CLASS2 0 88A 0 88A 3 HANDLING This section explai
26. the personal computer Failure to do so can result in a fire failure or malfunction Always ground the personal computer to the protective ground conductor Failure to do so may cause a malfunction 2 Precautions for communication cable wiring N CAUTION Special skills and tools are required to connect the communication cable to the connector plug which is an exclusive product When purchasing it please consult your local Mitsubishi representative Incomplete connection can result in a short fire or malfunction Securely plug the communication cable to the connector of the CC Link IE Controller Network board Then check for any incomplete connection Poor contact may cause an erroneous input or output Place the communication cables connected to the CC Link IE Controller Network board in a duct or clamp them If not dangling cables may swing or inadvertently be pulled resulting in damage to the board or cables or malfunctions due to poor contact Remarks For optical fiber cables refer to the MELSECNET G Network System Reference Manual Controller Network 16 3 Precautions for external power supply cable wiring N CAUTION Verify the rated voltage and pin out and connect the external power supply cable properly Connecting a power supply with a different voltage rating imperfect cable crimping or faulty wiring may cause a fire or fa
27. to the M of Economy Trade and Industry for service transaction permission Specifications subject to change without notice Printed in Japan on recycled paper
28. tware license agreement Software registration card 1 CD ROM contains the User s Manual in PDF format 2 PERFORMANCE SPECIFICATIONS Performance specifications of the CC Link IE Controller Network board are shown below Q80BD J71GP21 SX Q80BD J71GP21S SX Specification Q80BD J71GP21 SX Q80BD J71GP21S SX 32K points 32768 points 4K bytes Max link points 128K points 131072 points 256K bytes per network 8K points 8192 points 1K byte LY 8K points 8192 points 1K byte LB 16K points 16384 points 2K bytes Max link points LW 16K points 16384 points 32K bytes per station LX 8K points 8192 points 1K byte LY 8K points 8192 points 1K byte Transient transmission Up to 1920 bytes capacity Communications speed 1G bps Number of stations per network Connection cable Optical fiber cable Multi mode fiber Overall cable distance 66000 m When 120 stations are connected Station to Min 2m station distance Max 550 m Core clad 50 125 um Max number of networks 239 Max number of groups 32 Transmission path Duplex loop Communication method Token ring method Synchronization method Flag synchronization Frame synchronization Encoding method 8B10B Transfer format Ethernet II FCS Frame Check Sequence CRC32 of the frame Ethernet compliant Loop back function by error detection and cable disconnection System down prevention by control station switching Error de
29. uencies e Holes made in the control panel must be 10 cm 3 94 in diameter or less If the holes are 10 cm 3 94 in or larger radio frequency noise may be emitted In addition because radio waves leak through a clearance between the control panel door and the main unit reduce the clearance as much as practicable The leakage of radio waves can be suppressed by the direct application of an EMI gasket on the paint surface Maker name Series type KITAGAWA INDUSTRIES CO LTD US series ZIPPERTUBING JAPAN LTD 71TS series SEIWA ELECTRIC MFG CO LTD E028 A Our tests have been carried out on a panel having the damping characteristics of 37 dB max and 30 dB mean measured by 3 m method with 30 to 300MHz 12 2 Connection of power and ground cable The power supply cable and ground cable for a personal computer should be laid out as follows a b Provide a grounding point near the power supply of personal computer Ground the FG frame ground terminal of the personal computer and the SLD shield terminal of the CC Link IE Controller Network board with the thickest and shortest grounding wire wire for grounding possible about 30 cm 11 81 in or less in length Since the FG and SLD terminals function to ground the noise generated in the personal computer it is necessary to ensure the lowest possible impedance As the wires are used to relieve the noise the wire itself
Download Pdf Manuals
Related Search
Related Contents
Samsung ME109F-1SH User Manual Conexión del Disco Duro Portátil User Instruction Manual MOD-MBUS CONFIGURATOR SOFTWARE User Guide S`asseoir pour se regarder… conseiller (expertiser, évaluer MANUAL DE INSTRUÇÕES TERMO DE GARANTIA MANUAL DE CARA`MAG` - Printemps 2011 - Communauté d`Agglomération RIDGID R86008K2 Use and Care Manual Life Fitness SL65 User's Manual Emerson 1098-EGR Drawings & Schematics Copyright © All rights reserved.