RD 301 Echo sounder remote display
Contents
1. 9 pin D connector Rx gt 2 Tx 3 round 5 Looking into female 9 pin D pin connector Looking into male 9 pin D pin connector To plug housing W103 Rev G Standard RS 232 serial line This cable comprises a multi purpose serial line It provides interface with any peripheral unit One end of the cable connects to the local unit DTE with a 9 pin D connector while the other connects to the peripheral DCE as described in the peripheral unit s documenta tion Note that this cable does not support all the sig nals in the standard RS 232 specification Note about wiring A wrong type of cable has been used in the production of the first series of RD301 repeaters This applies to repeaters with serial no 030031 through 030050 WIRING CONNECTING a l COEUR stea ateu sena Two Of the wires in the cable have a different RED 24V GREEN DIM colour coding from the original alia i ae a m NMEA IN OUT Brown wire BLUE NMEA IN GREY DIMKEY we WHITE NMEA IN OUT originally white ORANGE NMEAOUT gt remote DIMKEY Violet wire DIM lt DIMMER A originally grey Other cables as marked on the rear wall of the GROUND WITH GROUND STUD repeater About this manual Warning damage or injury caused by Copyright Kongsberg Simrad AS makes every effort to e
2. Instruction manual KONGSBERG Remote display RD3O1 Digital depth repeater 356g REMOTE DISPLAY 4 RD301 User manual INTRODUCTION The RD301 remote display is made for use with the EA400 EA600 and the EN 250 navigation echo sounder It may also be used with other echo sounders if they have NMEA0183 output The RD301 is a depth repeater with alarm setting The operator may select alarm depth in the meny Maximum depth readings are 9999 m and a resolution of 0 1 m Brightness is adjusted on the front panel Brightness can optionally also be adjusted from a remote controller OPERATION 1 To switch the unit on Press any key To switch the unit off At the same time press both the Up and the Down key To adjust brigthness Press the Up Down keys to find suitable setting To select depth alarm Press the S key once and enter alarm setting mode The display shows SetA Set the wanted depth by using the Up and Down keys When wanted alarm depth is set the unit will go back to normal mode operation after 15 seconds or press S to the depth occur When depth below transducer become the same or less than the alarm depth the display will indicate AL alternating with actual depth To set alarm off Repeat operation number 3 and set alarm depth to 0 m To select readings in feet meters or fathoms Press the S key twice and enter alarm setting mode The display shows SetU Select requ
3. Text string indicating transducer position FWD AFT PORT STB If position is not preset by operator empty field is provided Cd7019 PANEL MOUNTING Depth amp Draught SDDPT xxxx x Xxxx X XXXx x lt Cr gt lt Lf gt used by EA400 and EA600 Depth below transducer SDDBT xxxx x f xxxx x M xxx x F Depth below transducer by EN 250 proprietary sentence shown to the left only for EN 250 A Make a cut out in the Panel 5 125 x 125 mm B Remove the mounting bracket 1 C Unscrew the 4 screws in the frame 3 one in each corner and remove the frame D Put the Monitor 4 in the cut out and mark the 4 center points for the drill in the Panel 1 2 The drilling holes diam depends on thickness and material in the Panel E Use appropriate bolts with diameter 2 9 mm Length Mounting bracket depends on the Panel thickness F Finally put on the frame 3 Make sure that the screw heads correspond with the cut outs in the frame Nut M4 Ground stud 4M x 12 Tab size 6 3 x 0 8 Washer DIN 6797 2x Before fixing the monitor 4 in the cut out area in console 1 2 apply sufficient amount of water sealant compound between the monitor 4 and console 1 2 Before the frame 3 is remounted apply sufficient amount of water sealant compound in the inner area of the frame and on the edges of the monitor 4 to ensure that water can
4. ested reading by pressing the Up or Down key When readings is set the unit will go back to normal mode operation after 15 sec or press S to the depth occur To select transducer position Only for EN 250 Press the S key three times and enter the transducer selection mode The dis play shows SetP Press the Up Down keys to select between the four choices Unknown Forward Backward or Auto The Unknown selection decode any NMEA depth message and shows the depth on the display The position leds will then be off The other selections decode the NMEA message PSKPDPT If Forward is selected only the readings from the forward transducer is shown and if Backward is selected only the readings from the backward transducer is shown The Auto selection switches between Forward Backward and Unknown depending on the NMEA messages available The led for positions will shift automatically and blink every third second indicating that the Auto selection is active If the transducer position is unknown both leds will be on and blinking 857 164821aa NMEA Input RD301 User manual 1 Accepted messages NMEA0183 version 2 30 talker identifier is not processed PSKPDPT x x x x X X XX XX C C hh lt CR gt lt LF gt Transducer location Echo sounder channel number 0 99 Bottom echo strength 0 9 Maximum range scale in use meters Offset from transducer meters Water depth relative to transducer meters
5. not pen etrate into the monitor 4 The front panel of the monitor is waterproof Cable length 1 5m 4 9 ft 144 5 669 O O O A Ath 144 5 669 ini a JE A KONGSB O v LU E EA 50 1 968 lt _ _ __ gt 70 2 736 100 3 937 CD7018 Hole diam C4 0 0 157 132 5 5 217 gt gt o gt Cut out 125 4 921 96 3 780 s L lor pi KONGSBERG ROM lt 4 9 125 4 921 4 The drilling holes diam depends on thickness and material in the Console Some remote displays may have the text REMOTE DISPLAY instead of RD301 on the front 857 164821aa RD301 User manual Environmental conditions according to IEC60945 Supply voltage Power consumption Display area size 24 Vdc 20 32 V 3 Wat 24 V 20 x 11 mm Operating temperature 15 to 55 degree C according to IEC60945 To increase service ability and life time we suggest the working temperature to be held at 0 to 40 degrees C Storage temperature Humidity Protection 20 to 70 degree C 10 90 relative no condensation IP 56 Generic RS 232 Serial line Remote unit DCE to be connected as described in applicable documentation Screen Local DTE
6. nsure that the information contained within this document is correct However our equipment is continuously being improved and updated so we cannot assume liability for any errors which may occur The equipment to which this manual applies must only be used for the purpose for which it was designed Improper use Or maintenance may cause damage to the equipment or injury to personnel The user must be familiar with the contents of the appropriate manuals before attempting to install operate or maintain the equipment Kongsberg Simrad AS dis claims any responsibility for improper installation use or maintenance of the equipment Service All service requests should be made to the local Kongs berg Simrad representative Adjustments and repairs should only be performed by qualified service engineers and unqualified repair attempts will void the warranty 2003 Kongsberg Simrad AS The information contained within this document remains the sole property of Kongs berg Simrad AS No part of this document may be copied or reproduced in any form or by any means and the infor mation contained within is not to be communicated to a third party without the prior written consent of Kongsberg Simrad AS KONGSBERG MARITIME AS Strandpromenaden 50 P O Box 111 N 3191 Horten Norway Telephone 47 33 02 38 00 Telefax 47 33 04 44 24 www kongsberg com KONGSBERG 857 164821aa
Download Pdf Manuals
Related Search
Related Contents
Jeudi 9 Atelier pratique LUNETTES ET TELESCOPES : MODE D BLU-50 - HARMAN Professional User manual LMB 6023-X2 - Balogh technical center Speco Technologies SIPSD10X Security Camera User Manual Quiz Show Manuale d`istruzioni del rugosimetro PCE-RT 10 Handleiding Mode d'emploi User guide - Boobs-'n RHD-FAN取扱説明書 - アイ・オー・データ機器 Notice utilisateur Copyright © All rights reserved.