Home
Arming mode “Stay” – AA Functional keys for quick
Contents
1. ENT la amp 2 gt o 1 Partial Arming This is universal way of arming which enables to arm selected partition in desired arming mode In case of partial arming Green LED will blink slowly 1 example ENT Arming lt 4 Vacation Nt PIN Pins ENT Parts ENT 2 example ENT Arming END gt V gt Away ENT PIN Pm Ent Parts gt ENT D 1 example 2 example Arming and disarming of security barrier Pre alarm mode Microwave or infrared rays based security barriers also outdoor PIR detectors which are connected to the system can be armed by Pre alarm mode The system will sound an alarm without sending alarm message to Central Monitoring Station when someone travers this electrical barrier The Pre alarm mode can be turned on and turned off the same way as described below For the more convenient control of Pre alarm is recommended to create special F keys during installation process Via Menu Est v gt gt Prealarm N PIN PiN Ent Parts gt C ENT a gt Bypassing zone B If you want to arm the system with zones which are violated for example with opened windows it s necessary to determine that the system bypass these zones Bypass procedure can be made F key Ba ENT PIN PIN ENT Via Menu ENT V gt V V gt g
2. 5 record SECOL ink MAS 800 KM20 KM20T keypad Intruder alarm system Short user manual j Sensor operation testing testing zones F22 Itis recommended to do sensor work test at least one time per month During a test itis necessary to make a violation of zone it means to open door or windows which have magnetic contacts or to simulate movement near the motion sensor Glass break detector can be tested by hard clapping hands Testing F key CF 2 2 ent PIN ENT ie Via Menu ENT lt 4 lt 4 44 4 a 4 Tests nt Burg Zone Tes ENT ENT 1 Testing zone Testing zone is not violated is violated Zones which were violated are checking by pressing the 45 key test finishes by pressing Permission to make changes of the system service mode entry F33 Si For security reasons Installer will have permission to make changes of the system setting only after S 7 User approves it by entering his PIN PS F key LF 3 3 J ent Enable Service User PIN Pin Ent ServicePIN Via menu nT lt 4 Service mode 7 Enable Service User PIN Pit ENT ServicePIN PIN Activated User PIN code changing F20 The manufacturer provides the system with 4 digit number default PIN which are suited to system s User count number For example the default PIN for the first User will be 0001 f
3. and the entry door weren t opened after entering PIN it is necessary to make decision either to arm disarmed partitions or to disarm armed ones Disarming when staying in protected premise BB or FO Nevertheless are there all partitions armed or not all partitions which are controlled by User will be disarmed Disarming F key F 0 ENT PIN ENT Or _Ba Ba ENT PIN s ENT The first partition disarming when staying in premise B1 Nevertheless are there all partitions armed or not the first partition which is controlled by User will be disarmed Disarming F key Ba e1 ENT PIN ENT The second partition can be disarmed with 84 2 both partitions with 841 2 onenn EEEE decis Sarm disarmed partition Arae Full disarming PiN EnT v gt Disarming ENT All partitions ENT a Partial disarming PN EnT V Disarming EDC gt Selected parti st Parts ENT EEEE EELEE Alarm clearing If an alarm has occured on the display appears message Alarm with an explanation what reason caused it Alarm LED is turned on the siren starts to sound and report about alarm is sending to CMS or to alarm the User There are 2 ways to clear alarm and turn off red LED 1 way pressing the CLr PIN ENT After performed alarm clearing action siren stops to sound alarm LED goes off the system status remains trouble the sam
4. countries As A ENT PIN ENT for non EU countries is available A As ENT Pe Via Menu ext Arming Nt lt 4 lt 4 Stay nT PIN Pins Ent Parts gt ENT allzones will be protected entry delay is off alarm will sound upon opening door Arming F key As As Ao ENT PIN Pinses ENT ieee Via Menu Ext Arming Vacation Ent PIN ss Ent Parts ENT WN Arming mode Vacation AAA This arming mode is used when we are leaving the premise for a long period e g vacations After arming g Pig JAS C Maximum Arming for the first partition A1 a Only the first partition is armed This way of arming is available in 2 storied house when at night the ground floor isn t used all sensors of this partition are armed also there isn t entry delay for door so nobody suppose to enter the house the second or both partitions canbe armed analogously with A2 or A12 Arming F key for EU countries A 1 ENT PiN ENT for non EU countries is available A 1 ENT Via Menu ET Arming 45 Vacation EN PIN vs Ent Parts ENT SECOLink MAS 800 KM20 KM20T keypad Intruder alarm system Short user manual wx C Arming the first partition with entry delay on A1A Only the first partition is armed This kind of arming is available in 2 storied house when at night the gr
5. SECOL ink MAS 800 KM20 KM20T keypad Intruder alarm system Short user manual Enviroment temperature SECOLink only for KM20T MAS 800 alarm Date System s state LED indication armed Pre alarm indication pre alarm trouble Time There is 1 partition in the Emergency keys Remote control is allowed system The partition isn t 2 3 CLR by radio remote control unit armed and there are no zones which are violated N For example for gates 5 6 ja A Functional keys _ Main menu F keys navigation keys 8 9 V gt Ni i i F 0 ENT There are 4 partitions in system in the first one there are zones which are violated the second partition is armed in the Night mode This key is used for partition review This key is used for zone review the third partition is disarmed and hasn t violated zones also for marking all partitions or also for marking the partitions and the fourth partition is armed in the Away mode selecting another element L other elements of the system for example for User selecting for example for marking zone which ll be bypassed Functional keys for quick and comfortable control of the system Security system SECOLink is supplied with standard described below functional keys F key set It allows by one or two pressings of the keypad keys perform generally using function avoiding t
6. e as was before alarm If the system has smoke detector and alarm was caused by smoke which was raised by domestic reasons the system will start alarm nevertheless it was armed or disarmed The only way to clear alarm is possible by bypassing of smoke detector see 2 page Bypassing zone B 3 2way entering PIN code After performed alarm clearing action siren stops to sound alarm LED goes off the system will be disarmed if it was armed before entering PIN code When all partitions which are controlled by User are disarmed it s not recommended to use PIN for alarm clearing because is possible casual arming armed Event log review F30 F31 All events which are concerned with protected premises and status of the system are stored in the event log Reviewing event log F key CF 3 o ent ALARMS events F 3 1 Ent FAULTS events Via Menu ENT gt V gt gt E E Event Log T Alarm Event Ent PIN ENT To display time or date event press the key next event is selected the lt 4 gt key Electronic notebook memo review F09 Allimportant contact information phone No e mail Installer can write outon keypad Review F key CF o 9 ENT 1 record gt 2 record gt 3 record 4 record 5 record Via Menu ENT lt 4 4 memo ENT 1 record 2 record 3 record 4 record
7. e usual arming procedure alarm SECOLink MAS 800 KM20 KM20T keypad Intruder alarm system Short user manual Emergency keys In order to call for a help the premises must be secured by CMS press at once two specific keys and hold them at least 1 second When emergency alarm occurs siren starts to sound and alarm message will be shown on the keypad display Fire alarm A 61 Medical alarm 84 f4 Panic alarm Co G7 Ways of disarming Disarming can be done by three ways F key entering PIN code Via Main Menu Using F key or entering PIN all partitions which are controlled by User will be disarmed After disarming via Menu it s necessary to unmark the partition which we don t want to protect The partition which will be disarmed is denoted the or keys and this action is confirmed by pressing the EN key Disarming by PIN code when entering the premise After opening the door which are protected the system begins to count the entry delay During this time it is necessary to enter PIN code and confirm by pressing the nT key All partitions which are controlled by User will be disarmed Disarming by PIN code when staying in protected premise When all partitions are armed and the entry door weren t opened after entering PIN all partitions which are controlled by User willbe disarmed Disarming PiN ENT When part of partitions are armed
8. he control of the system via Main Menu During the installation is available to make individual F keys which are maximum fitted for the object s protection and for the F key User s needs If you press the F key and then the asor k keys you can review list of available F keys F key the name Ways of arming The system can be armed by three ways F key via Main Menu entering PIN code Using F key all partitions which are controlled by User will be armed When Arming is activated via Menu it s necessary to mark the partitions which will be armed mark the partitions with or and confirm with amp 7 When arming is activated by Entering PIN code it will bearmedin Away mode wx Arming mode Away A This arming mode is used when you want to protect a premise when nobody will be staying inside After J A arming all Zones will be protected After using the door will be entry delay time for disarming Arming F key for EU countries A ENT PIN ENT for non EU countries is available 42 ENT PIN code Pin ENT via Menu Ent Arming lt gt All partitions D PIN ENT x Arming mode Stay AA This arming mode is used to protect a house when we are staying at home inside and are waiting that 8 somebody can come in Interior zones aren t protected After opening the door willbe entry delay Arming F key for EU
9. ignal LCD display keypad keys about opening of entry exit door or violation of other selected zone From which zone chime will be activated you can set by pressing the key on selected zone The chime zone willbe markedas 4 ViaMenu Ent 44 4 4 lt 4 Options ENT gt Chime ENT PiN EnT v gt Jv gt ENT Setting Date and time F21 F key LF 2 1 Ent Date and Time ENT enter date and time ENT Via Menu ENT lt 4 4 lt 4 lt 4 Options ENT ENT Date and Time ENT enter date and time En Temperature correction on keypad display F11 only KM20T If the keypad shows an incorrect enviroment temperature it is recommended to make temperature correction which can be done by entering value of temperature measured with domestic thermometers The correction can be made Via Menu nT 4 lt 4 lt 4 lt 4 Setting E Temperature ENT lt 4 Temper correction ENT Pin ENT enter temperature value ENT PIN Activated Users review F23 After system installation is recommended to review how many Users can control the security system F key F 2 3 ENT PIN ENT vp mode x Ce C Via Menu nT 4 4 4 4 setting ENT gt gt Users ENT gt edit User ENT PiN Ent v gt mode x x x LCD displa
10. or the second User 0002 and etc After installation itis strongly recommended to change default PIN F key FC 2 0 EnT Change PIN Pin JIEnT New PIN Pin JienT Repeat Pin ENT Changed Via Menu nT lt 4 lt 4 4 4 4 Options ent gt Users ENT Ent Change PIN Pins Ent New PIN PiN ENT Repeat C ENT Changed The example The User of the system has a PIN 1234 When he feels that PIN isn t secure he can change it by pressing sequence of keys F 2 0 lent Change PIN 1234 nt New PIN 3762 Ent Repeat 3762 Nt Changed Keypad display and keys backlight changing F10 User has possibility to change contrast and backlight intensity of keypad LCD display also he can select conditions when keypad keys will be illuminated Default settings button s illuminating starts up after pressing the button or when occurs entry delay or alarm trigger For illuminating buttons all the time it is necessary to perform such actions F key CF 1 0 J ENT Keypad Settings n Ent Light ENT gt LCD amp keypad E87 Changed CLR CLR Via Menu nT 44 44 lt 4 lt 4 Options ENT lt 4 lt 4 lt 4 Keypad settings E87 PIN ENT Light ENT V LCD amp keypad Ent Changed CR cer CLR Chime mode Chime function is used to inform User with the sound or light s
11. ound floor isn t used all sensors of this partition are armed When somebody opens doors will be an entry delay The second or both partitions canbe armed with A2A or A12A respectively Arming F key for EU countries 4s 1_ As ENT PiN ENT for non EU countries is available CAs 1 As ENT Via Menu ext Arming st gt gt Away amp st PIN ins ent Parts Ci ENT Arming mode Night C This arming mode is used when you want to arm the system with the person staying inside of the premise The interior zones are left disarmed if anyone opens door won t be the entry delay and the alarm will sound This arming mode is effective when the door and windows are secured by the opening sensors or there are installed glass break detectors Arming F key for EU countries c3 ENT Ent for non EU countries is available ce ENT Via Menu ENT Arming 7 Night 7 PIN Ent Parts ENT Forced Arming F AAAA The arming mode that allows to arm the system when the zones are violated or the sensor is broken All sensors which were remained earlier will be armed After opening the entry exit door the system will give entry delay time Arming F key for EU countries F ENT Pin Ent for non EU countries is available F ENT Via Menu ext Arming St e gt gt gt Forced Arming END PIN Pit
12. t Zone Bypass ENT PIN PIN ENT A Zone is bypassed Zone isn t H Zone is violated violated ES The zone which you want to bypass is selected with lt 4 or V keys and is marked the key If selected zone is bypassed the symbol X will be shown on display Bypass procedure is finishing by the ENT key The zone is bypassing for one arming disarming cycle Abort arming For selecting also for aborting arm procedure the system SECOLink has the er key If the exit delay is in process and you want toabort arming press the CLR key enter PIN and confirmit with the ENT key Arming system with troubles EU standards unexpect using of the system which has troubles When Yellow LED is on the arming is impossible in the ways which were discribed earlier It is necessary immediately eliminate troubles also armad inform CMS and company which had installed the system The system detects troubles in own modules also it detects and other common troubles like 230V disappearance in AC line disconnected phone line roe because of repair battery discharge In exceptional cases is possible to bypass the troubles for a short time and arm system as usual It can be done this way 3 Press the ct key once message about the trouble will be shown on the display then press key again Yellow Trouble LED starts to blink fast The blinking duration is 30 seconds during this time is possible to mak
13. y will show User number for example U01 and mode Enabled or Disabled All Users who have mode Enabled can control system or it s partitions CE System compliance and warranty The system is made in Lithuania warranty term is 24 months The manufacturer company Kodinis Raktas declares that product SECOLink complies with essential EU directive and EU standard EN 50131 1 See manufacturer s web site www kodinis It for complete text of declaration 2010 Kodinis Raktas