1. Channels are configured independently of one another Diagnostic indicator 2 Order information Description Inline terminal with eight analog output chan nels for analog standard voltage signals com plete with accessories connectors and labeling fields transmission speed 500 kbps Optional Add Ons Purchase via Phoenix Contact ILT AO 4 8 U BP Part number 1225 100492 01 5 1 Description Type Part no Pcs Pkt Inline shield connector for analog Inline terminals IB IL SCN 6 SHIELD TWIN 2740245 5 Shield connection clamp for applying the shield on busbars SK 8 3025163 10 Shield connection clamp for applying the shield on busbars SK 14 3025176 0 Shield connection clamp for applying the shield on busbars SK 20 3025189 0 Shield connection clamp for applying the shield on busbars SK 35 3026463 10 Support for mounting on the NS 35 7 5 DIN rail for 10 mm x 3 mm bus AB SK 3025341 0 bars Support for direct mounting with contact to the mounting surface AB SK 65 3026489 10 Support made of insulation material with fixing screws can also be used AB SK E 3026476 0 for 10 mm x 3 mm or 6 mm x 6 mm busbars PEN conductor busbar 3 x10 mm length 1000 mm NLS CU 3 10 SN 1000MM 0402174 0 Power terminal cross section 0 5 4 mm width 7 mm AK 4 0404017 50 Power terminal cross section 0 5 4 mm width 7 mm AK 4 GNYE 0421029 50 color green and yellow Power terminal cross section 0 5 4 mm width 7 mm col
2. be reproduced or modified in any form without prior written agreement with SysMik GmbH Dresden Copyright 2014 by SysMik GmbH Dresden SysMik GmbH Dresden Tel 49 0 351 433 58 0 Bertolt Brecht Allee 24 Fax 49 0 351 4 33 58 29 01309 Dresden E Mail Sales sales sysmik de E Mail Support service sysmik de Germany Homepage www sysmik de 2 sysmik de ILT AO 4 8 U BP Contents Contents Device description 1 Contents 3 1 Description 4 2 Order information 4 3 Technical data 5 4 Local diagnostic and status indicators Terminal point assignment 8 4 1 Function identification 4 2 Terminal point assignment per each connector 8 5 Internal circuit diagram 9 6 Electrical isolation 10 7 Installation instruction 10 8 Connection notes 11 9 Connection example 11 10 Connecting shielded cables using the shield connector 12 ILT AO 4 8 U BP sysmik de Description Order information 1 Description A Note This device description is only valid in association with the IL SYS INST UM user manual or the Inline system manual of the specifically used bus system Make sure you always use the latest documentation it can be downloaded at www sysmik de The terminal is designed for use within an Inline station This terminal provides an 8 channel output module to output analog standard voltage signals Features Eight analog signal outputs Actuator connection in 2 wire technology with shield connection
3. Fields Type of Electromagnetic Interference Typical Deviation of the Output Range Final Value Relative Electromagnetic fields field strength 10 V m lt 0 5 according to EN 61000 4 3 IEC 61000 4 3 Conducted interference Class 3 test voltage 10 V lt 0 5 according to EN 61000 4 6 IEC 61000 4 6 Fast transients burst 4 kV supply 2 kV input ac lt 0 5 cording to EN 61000 4 4 IEC 61000 4 4 Approvals Information on current approvals can be found on the Internet at www sysmik de ILT AO 4 8 U BP sysmik de 7 Diagnostic and status indicators Terminal assignment 4 Local diagnostic and status indicators Terminal point assign ment Designation Color Meaning D TR PCP active Fig 1 Terminal with appropriate connector 4 1 Function identification yellow 42 Terminal point assignment per each connector Terminal Sue Assignment point 1 1 Voltage output 1 2 1 Voltage output 2 1 2 2 2 fe Not used 1 3 2 3 AGND Ground of voltage output 1 4 2 4 Shield Shield connection 8 sysmik de ILT AO 4 8 U BP Circuit diagram 5 Internal circuit diagram Et T A ea ae Super visor Voltage Monitoring iy Da A 24 VU A QU U du 24 V U ea A to te T a Fig 2 Internal wiri
4. Inline terminal 8 analog signal outputs ILT AO 4 8 U BP Device description Preliminary SSI GmbH Dresden Disclaimer Imprint This manual is intended to provide support for installation and usage of the device The information is believed to be accurate and reliable However SysMik GmbH Dresden assumes no responsibility for possible mistakes and deviations in the technical specifications SysMik GmbH Dresden reserves the right to make modifications in the interest of technical progress to improve our modules and software or to correct mistakes We are grateful to you for criticism and suggestions Further information device description available software can be found on our homepage www sysmik de Please ask for latest information SysMik disclaims all warranties in case of improper use or disassembly and software modifications not described in this document or when using improper or faulty tools Commissioning and operation of the device by qualified personnel only All applicable regulations have to be observed SysMik and the SysMik logo are registered trademarks of SysMik GmbH Dresden IPOCS is trademark of SysMik GmbH Dresden Networking Together is subject to copyright of SysMik GmbH Dresden All other trademarks mentioned in this document are registered properties of their owners These and further trademarks are used in this document but not marked for better readability No part of this document may
5. analog terminals behind all the other terminals at the end of the main circuit 10 sysmik de ILT AO 4 8 U BP Connection notes Connection example gt BD gt Connection notes Analog actuators with a cable length of lt 10 m can be connected using unshielded twisted pair ca bles Connect analog actuators with a cable length of gt 10 m using shielded twisted pair cables Connect one end of the shielding to PE Fold the outer cable sheath back and connect the shield to the terminal via the shield connector clamp with strain relief The clamp connects the shield direct ly to FE on the terminal side Ensure that the braided shield is 15 mm longer than the strain relief when connecting a shielded actuator cable to the I O connector Connect the actuator cable as described in Connecting shield ed cables using the shield connector see p 12 Connection example Use a connector with shield connection when installing the actuators Figure 4 shows the connection schematically without shield connector Steckplatz 1 2 3 4 Kanal Fig 4 12345678 D TR AO 4er Connecting actors ILT AO 4 8 U BP sysmik de 11 Connecting shield 10 Connecting shielded cables using the shield connector A The diam
6. ctor see user manual C Place the shield connection clamp in the shield connector corresponding to the cable width see user manual Place the cables in the shield connection D Push the outer cable sheaths up to the shield connection clamp The wires with the braided shield must be underneath the shield connection clamp The braided shield must project ap proximately 15 mm over the shield connection clamp Close the shield connector E Fasten the screws for the shield connector using a screwdriver F 12 sysmik de ILT 24 DI 16
7. eter of the actuator cable is usually too large to allow the cable to be installed into the strain relief of the shield connector with sheathed and folded shield The connection procedure for this ca ble therefore differs from the connection procedure described in the user manual The comparative differences with the user manual are marked in bold text Connection of the cables according to Figure 5 should be carried out as follows Stripping Cables Strip the outer cable sheaths to the desired length a A The desired length a depends on the connection position of the wires and whether the wires should have a large or small amount of space between the connection point and the shield connection Shorten the braided shield to 20 mm A Do not fold the braided shield back over the outer sheath B Remove the protective foil Strip 8 mm off the wires B A Inline wiring is normally without ferrules However it is possible to use ferrules If using ferrules make sure they are properly crimped Wiring Connectors According to User Manual Push a screwdriver into the slot of the appropriate terminal point so that you can insert the wire into the spring opening Recommended screwdriver with blade measures of 0 6 mm x 3 5 mm Insert the wire Remove the screwdriver from the opening The wire is now clamped The connector pin assignment can be found in the table on page 8 Connecting the Shield Open the shield conne
8. ng of terminal points Key one Protocol chip Digital analog converter De Register expansion REF Reference voltage Level adaption Le Output level Supervisor Hardware monitoring Ms Voltage monitoring DC DC converter with electrical isola C Microcontroller 7 tion Optocoupler D Analog ground electrically isolated from ground of the potential jumper Note Other symbols used are explained in the IL SYS INST UM E user manual or in the Inline sys tem manual for your bus system gt ILT AO 4 8 U BP sysmik de 9 Electrical isolation Installation instruction 6 Electrical isolation a Lokalbus IN i gt Busanschaltung EB Lokalbus OUT I E OPC U 7 5 V DC me und Mikrocontroller U 7 5 V DC J t U 24 V DC Una 24 V DC EE A Peripherie B Interface SS Potenzialtrennung zwischen Bereich AundB FF fl FE Potenzial Analoge Ausg nge Fig 3 Electrical isolation of the individual function areas 7 Installation instruction High current flowing through potential jumpers Uy and Us leads to a temperature rise in the potential jump ers and inside the terminal Observe the following instructions to keep the current flowing through the po tential jumpers of the analog terminals as low as possible A Create a separate main circuit for the analog terminals If this is not possible in your application and if you are using analog terminals in a main circuit togeth er with other terminals place the
9. or black AKG 4 BK 0421032 50 User manual IL SYS INST UM 2698737 1 Automation Terminals of the Inline Product Range User manual IB ILSYS PRO UM 2743048 1 Configuring and Installing the INTERBUS Inline Product Range 4 sysmik de ILT AO 4 8 U BP Technical data 3 Technical data 25 C to 85 C Permissible humidity operation storage transport 10 to 95 according to DIN EN 61131 2 Permissible air pressure opera 70 kPa to 106 kPa up to 3000 m above sea level tion storage transport Conductor cross section 0 2 mm to 1 5 mm solid or stranded 24 16 AWG Interface Data routing 500 kBit s 500 kBit s Communications power UL 7 5 V DC Current consumption from UL 80 mA typical I O supply voltage Uana 24 V DC Current consumption at Uana 72 mA typical Total power consumption 2 35 W typical Supply of the Module Electronics and I O Through the Bus Coupler Power Terminal Connection method Potential routing ILT AO 4 8 U BP sysmik de 5 Technical data Analog Outputs Number Eight analog voltage outputs Signals Representation of output value 16 bits 15 bits with sign bit or 8 bits 7 bits with sign bit 16 bits Resolution quantization Inline format 5 V 5 419 V to 5 419 V 0 167 mV LSB Voltage 0 1 typical of the output range final value Output load 2 kW minimum 30 kW typical Actuator cable length 250 m maximum using shielded cable 10 m maximum using un
10. shielded cable Safety Equipment Transient protection of analog outputs Short circuit protection of analog outputs Yes for at least 1 minute Electrical Isolation Common Potentials 24 V main voltage Um 24 V segment voltage Us and GND have the same potential FE is a separate potential area Separate Potentials in the Terminal Test Distance Test Voltage 7 5 V supply voltage 15 V 500 V AC 50 Hz 1 min 7 5 V supply voltage bus logic functional earth 500 V AC 50 Hz 1 min ground 15 V 5 V analog supply analog I O functional 500 V AC 50 Hz 1 min earth ground Error Messages to the Higher Level Control or Computer System Failure of the internal I O voltage supply Yes I O error message sent to the bus coupler Failure of or insufficient communications power UL Yes I O error message sent to the bus coupler 6 sysmik de ILT AO 4 8 U BP Technical data Tolerance and Temperature Response Note The tolerance values refer to the measuring range final value at a typical load 30 kQ Th 25 C Output range Absolute Absolute Relative Relative typical maximum typical maximum OV to 5 V 45 V 0 36 0 50 0 V to 10 V 10 V 0 19 0 25 Ta 25 C 55 C Output Range Absolute Absolute Relative Relative typical maximum typical maximum 0V 105 V 45 V 0 44 0 80 O V to 10 V 10 V 0 26 0 40 Additional Tolerances Influenced by Electromagnetic