Home
VISION 575
Contents
1. sssnnseeosesennneeeeerettnntreseettttntseeetttrnnnttrttetnnnnnneeenrnnnnneeerettn netee 11 7 9 Rotating gobo wheel seanar aa aaea aa E ara i a EE 12 PANG et EE E ETE ETA O TEE E EAE 12 7 1 Eff ct wheel iaar ar a a a r E EL a E 12 7 8 3 facet rotating prism ings aoe ns seed ec cet estes oe ewe ee hes secede Seen ewe eens 12 FSO FOCUS ou cteree aver ecove cess ar a Geen eax ones Ra aE p a E p Oe a rE E EaR come exes Ea 12 7 10 Dimmer Shutter SOD vated iessleu dessa Soe ei ddeieed deelae Se eek ee at dane a 12 See TA A A E Srseun eee av al ecas on al ocares als dcanddas E E EEE EET 12 SuCONtfOl BOSE AEE E E E E E T 12 8 1 Main TNC HONS a eee ec ical le a aa eA an ee a oes ce hee 13 8 2 SPEC Special functions ashe fi ieee stcccndecmcnendadael tartan pau nhdncmmccndsaedaeattesar rae boseredicnacends 14 9 Error and information messages ii iisicsisindeisansnsssesnetssisnacwancwendudccsansasasasiseriseaavacdvaneneis 19 10 Technicalspecificati nS ivivisseicenseiiacircatecidenndeiedededeusensananturasaneadaadnnedaundedidweeiaeeumandeaues 20 11 Maintenance and cleaning ccccccceceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeseeneeneeeneeeeenneneeeeeeeeeeeeees 22 12 Appendix seisen ceecntacwcuaucaeudaducucuduadvnnvennnnnnvaanvannonsceaunsuanacutidudususdesbusstweubteutienueasueueustaudaaues 22 CAUTION Keep this device away from rain and moisture Unplug mains lead before opening the housing FOR YOUR OWN SAFETY PLEASE READ THIS USER MANU
2. 15 Low fan speed operating By using this function you can choose 4 types of low fan speed operating Browse through this menu by the pressing and keys the display shows step by step these messages HIGH reG LoOF Lo HI Press Enter if you wish to select one of them or Menu to cancel and return to the menu high max speed of fans The cooling fan works on max speed max cooling continuous controlling of the fan speed the fan automatically raises its speed in order to control inside temperature of the lighting if the temperature inside increases about certain level the low fan speed reduces the cooling of the lighting This cycle can repeat several times until the temperature inside is on suitable level low speed Switch Off the lamp operating the fan keeps the adjusted low speed until the temperature exceeds max inside temp then the VISION 575 automatically switch Off the lamp low high speed of the fan operating the fan keeps the adjusted low speed until the temperature exceeds max inside temp of the fixture then the VISION 575 automatically switch from low to high the fan speed Default settings Press Enter to reset all fixture personalities not the adjusting functions to the default values On the display will appear rSt meaning that the fixture makes the reset See the table of personality setting and their default positions Default value
3. Gobo 7 step Gobo 8 step Gobo 9 step Gobo 10 step 244 255 Gobo 11 step hannel Channel Value Type of control 16 bit 8 bit aa 0 1 179 180 191 192 223 224 255 0 31 32 63 64 95 96 127 128 159 160 191 192 223 224 255 Frost cor filters 3 facet prism Open position hole Frost filter 3 facet prism 3200 K correction filter 5600 K correction filter UV filter 3 facet prism rotation control No rotation Forwards rotation from fast to slow No rotation Backwards rotation from slow to fast Rotating gobos cont rotation Open Rot gobo 1 dichroic Rot gobo 2 glass Rot gobo 3 glass Rot gobo 4 glass Rot gobo 5 glass Rot gobo 6 glass Rot gobo wheel cont rotation from slow to fast Rotating gobo index rotating gobo rotation Gobo indexing Forwards gobo rotation from fast to slow No rotation Backwards gobo rotation from slow to fast Iris Open Max diameter to min diameter Closed Pulse closing slow to fast Pulse opening fast to slow Focus Proportional focus control Shutter strobe Shutter closed No function shutter open Strobe effect from slow to fast max 10 flashes s No function shutter open Pulse effect in sequences No function shutter open Random strobe effect from slow to fast No function shutter open Dimmer intensity Gradual adjustment of the dimmer intensity from 0 to 100 step proportional step proportional step step step step st
4. VISION 575 USER MANUAL LATION LUMINAIRES VISION 575 Table of contents Te Salety INStEUCONG s sies aenean nanaii adani ccudacedetatisusiveenstanandaweceudadviuadausetisnentmunanduenads 3 2 Operating determinations ciscciewciiigerssecewseiinesosededtautadaveusescecsanedesbdunedwcaunencrsusdeuncaswranawacs 4 3 Description of the device seccisciiciscesseccsccedeaistesdcedsandcestesneredseviasesneededdanniensseredanwiseadeuecnend 5 Ae Ee a AE ATT T 6 4 1Fitting ela cre tenttceuten then Redes aaa bien via na diac tad aia Eaa EEEE A h eh EAEE 6 4 2 Inserting Exchanging rotating gobos ssssssssssssssseeererererrrrrrrrrrrrrnrnnnnsnnsnssssssreenenne 6 4 3 Rigging the MXC ant rca attain al a ue eadt eee leh Le ke 7 4 4 Connection to the Mains sso see Beth he te Shit a NS held RE eee 7 4 5 DMX 512 connection connection between fixtures ecceeeeeeeeeeeeeeeeeeeeeeeeeteeeeaeees 7 5 DMX PROTOCOL isaac aaa ae a ea ar a a aa aaar a aa a aAA araa a aA HA a pa EPU Crea Ninaa Eit 9 Ea e Ko RLT AEE EE E E AE T 11 7 Remotely controllable functions 20 ccccceeceeeeeee cece eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeneees 11 Feel ETa Os aces aces aes pedis eet cheesey Supt vert c co au oo28 oes vais A eet ieee 11 7 2 Switching On and Off the lamp by the control board cceeeeeeeeeeeeeeeeeeeeeeeeeeeeees 11 TS Golur WHEE ae ssaterecarerisesetess re a Eea aa a E aE Dae aai aAA ao ia oc a EAE 11 7 4 Static gobo wheel
5. Enter to confirm or Menu to cancel and return to the main menu 13 Test program This function allows you to run a special test program without an external controller which will show you some possibilities of using VISION 575 Press the Enter key to run the test program Press Enter key to run reset This option enables the VISION 575 to index all effects functions and return to their standard positions 8 2 SPEC Special functions Use the and keys to browse through the special functions and select the one by pressing Enter NAnG Manual control of effects This function allows you to control manually the channel functions of the fixture Use the and keys to select desired function and press Enter to adjust the effect or Menu to cancel and return to the menu Pani kiti SPdi fo i SG O HOLE roPi rb0oG robi irii Foci OPEn and PAn tilt SPde fo 2 SG I Frob rof roo robe Irie Foc Str dini PAn3 tilt 5Pd3 Co 3 PHS o 5Pd4 SL 9 Fiti rof9 rbol rob iri FocS 5tr9 dint 5Pd5 Colb Stri Failte dial Flg Str 4 bout LAAJ Lamp On automatically This function enables to switch On the lamp automatically after switching On the fixture Use the and keys to select On if you wish to switch On the lamp automatically after switching On the fixture or Off if you wish the lamp off after switching On the fixture and press Enter to confirm or Menu to cancel and return to the menu dil in mae
6. Readout DMX values of each channel received by the fixture Use the and keys to select desired channel and press Enter to read its value coming to the fixture or Menu to cancel and return to the menu 0 255 0255 855 O55 0 255 O55 0 255 855 O55 O55 0 55 0 255 0 255 id 5P Automatic blackout of Display This function allows you to keep the display On or to turn Off automatically 2 minutes after last pressing any key on the control board Use the and keys to select On if you wish to keep the display On or Off if you wish to turn Off automatically 2 minutes after last pressing any key on the control board and press Enter to confirm or Menu to cancel and return to the menu Display intensity By this function you can adjust from 20 to 100 the intensity of the display Use the and keys to select the level of the display intensity and press Enter to confirm or Menu to cancel and return to the menu Lamp Off via DMX This function allows you to switch Off the lamp by DMX Use the and keys to select On if you want to switch Off the lamp by DMX or Off if you don t want to switch Off the lamp by DMX and press Enter to confirm or Menu to cancel and return to the menu Temperature Temperature readouts of fixture inside in Celsius Inside temperatures below 70 C are not critical 70 C and more lead to the lamp being switched off Please note that the outside temperature should not exceed 45 C
7. AL CAREFULLY BEFORE YOU INITIAL START UP 1 Safety instructions Every person involved with installation and maintenance of this device have to be qualilfied follow the instructions of this manual CAUTION Be careful with your operations With a high voltage you can suffer a dangerous electric shock when touching the wires This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual Important The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorized modification to the device Please consider that damages caused by manual modifications to the device are not subject to warranty Never let the power cord come into contact with other cables Handle the power cord and all connections with the mains with particular caution Always plug in the power plug least The power plug has to be accessable after installing the device Make sure that the power cord is never crimped or damaged by sharp edges Check the device and the power cord from time to time Always disconnect from the mains when the device is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord This device falls under protection
8. ain FrEr It will appear if the frequency of the main is not standard 50 or 60Hz 19 10 Technical specifications Power supply Voltage eeceeeeee 100 115 208 230 V AC 50 60 Hz F SSE horiari iiiar T 5 A 230V FUSC eceeeeeeeeeeeeeteeeeeees T 10 A 115V Power consumption 800 VA Motors 12 high quality stepping motors controlled by microprocessors Lamp HMI 575 Optical system Double condensor lens with high efficiency parabolic mirror Beampath STANDARD WIDE OBJECTIVE OPTIONAL NARROW OBJECTIVE 7100 1775 789 444 LUX 9030 2256 1003 564 LUX sey ES o 2 a2 17 oo aa OC St Haan f a ae Tt i 2 B iG 2 ray al a3 coe 0 5 10 15 20 DISTANCE m 0 5 10 15 20 DISTANCE m 0 1 36 2 63 3 95 5 27 DIAMETER m 0 1 05 2 10 3 15 4 20 DIAMETER m STANDARD WIDE OBJECTIVE WITH FROST OPTIONAL NARROW OBJECTIVE WITH FROST 1050 263 117 868 LUX 1312 328 146 82 LUX E ES 9 2 p o 2 z gp F p 25 ora Fa O z 2 z 5 LT a 3 D 3 0 5 10 15 20 DISTANCE m o 5 10 15 20 DISTANCE m 0 3 15 6 30 9 46 12 61 DIAMETER m o 2 49 4 98 7 48 9 97 DIAMETER m Colours 11 interchangeable dichroic filters plus white Colour wheel with variable rotation speed Static gobos 8 met
9. al gobos plus full circle 1 Multicolor dichroic gobo 2 dichroic gobos Rotating gobos 1 metal gobo 4 glass gobos and 1 dichroic gobo rotating in both dirrections at different speeds gobo indexing rotating gobo wheel cont rotation Strobe Strobe effect with variable speed 1 10 flashes per second 20 Dimmer Effects Prisma lris Focus Electronics Addressing special functions setting effects calibration via control panel with 4 digit LED display Readout fixture and lamp usage receiving DMX values temperature etc Built in analyzer for easy fault finding error messages Remotely switching of the lamp Bilt in demo sequences Silent fans cooling remotely controllable speed of fans Self resetable thermo fuse Digital serial inout DMX 512 DMX control via every standard DMX controller 14 DMX channels 8 bit Pan Tilt movement resolution 16 DMX channels 16 bit Pan Tilt movement resolution Temperatures Maximum ambient temperature t 45 C Maximum housing temperature t steady state 80 C Minimum distances Min distance from flammable surfaces 0 5m Min distance to lighted object 1 0m Housing Smooth dimmer from 0 100 Special effect wheel with frost filter color temperature filters 3200 K and 5600 K UV filter 3 facet prism rotating in both dirrections at different speeds situated on effect wheel Motorized iris for different beam diameters Motorize
10. ally detect whether DMX 512 data is received or not If there is no data received at the DMX input the display will start to flash A001 with actually set address This situation can occur if the 3 PIN XLR plug cable with DMX signal from controller is not connected with the input of the VISION 575 the controller is switched off or defective if the cable or connector is defective or the signal wires are swap in the input connector Note It s necessary to insert the XLR termination plug with 120 Ohm in the last lighting in the link in order to ensure proper transmission on the DMX data link 7 Remotely controllable functions 7 1 Lamp The VISION 575 is run with a HMI 575 lamp A relay inside of the VISION 575 allows you to switch On and Off the lamp via itself control board on the front panel or via your controller without affecting the rest of the lighting 7 2 Switching On and Off the lamp by the control board 1 Switch On the VISION 575 and wait until the fixture reset has finished 2 Press the Menu key in order to access the main menu Browse through the menu by pressing the and keys until the display shows LAMP Confirm by pressing Enter key 3 Use the and keys to select On for switch On the lamp and Off for switch Off the lamp and press Enter to confirm or Menu to cancel Note Itis also important to note that the discharge lamp is cold restrike types that means that they have to be c
11. cing the light output very quickly The cooling fan should be cleaned monthly The gobos may be cleaned with a soft brush The interior of the projector should be cleaned at least annually using a vacuum cleaner or an air jet The dichroic colour filters the gobo wheel and the internal lenses should be cleaned monthly To ensure a proper function of the gobo wheel we recommend lubrication in six month intervals The quantity of oil must not be excessive in order to avoid that oil runs out when the gobo wheel rotates 12 Appendix We believe you will enjoy your VISION 575 We assure you will enjoy this product for years if you follow the instructions given in this manual If you have any questions and comments please do not hesitate to contact us Please note errors and omissions for every information given in this manual excepted Every information is subject to change without prior notice Any claim due to missing or wrong information in this manual is herewith excluded 22
12. class Therefore it is essential to connect the yellow green conductor to earth The electric connection repairs and servicing must be carried out by a qualified employee Do not connect this device to a dimmer pack Do not switch the fixture on and off in short intervals as this would reduce the lamp s life During the initial start up some smoke or smell may arise This is a normal process and does not necessarily mean that the device is defective Do not touch the device s housing bare hands during its operation housing becomes hot For replacement use lamps and fuses of same type and rating only CAUTION EYEDAMAGES Avoid looking directly into the light source meant especially for epileptics 2 Operating determinations This device was designed for indoor use only If the device has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperature When taking the device into operation please make sure that the housing is closed firmly with all the necessary screws tightened up Never run the device without lamp Do not shake the device Avoid brute force when installing or operating the device When choosing the installation spot please make sure that the device is not exposed to extreme heat moisture or dust There should not be any cables
13. d focus from near to far Channel 1 Horizontal mirror movement 8 bit Channel 2 Vertical mirror movement 8 bit Channel 3 Fine Horizontal mirror movement 16 bit Channel 4 Fine Vertical mirror movement 16 bit Channel 5 Pan Tilt speed Channel 6 Fan speed lamp On Off reset Channel 7 Colours Channel 8 Static gobos Channel 9 Frost correction filters 3 facet prism Channel 10 Prism rotation Channel 11 Rotating gobos Channel 12 Gobo rotation gobo indexing Channel 13 Iris Channel 14 Focus Channel 15 Shutter strobe Channel 16 Dimmer Easy access to lamp and main components thanks to large opening cover and the projectors modular construction 21 Dimensions and weight LxWxH 670x240x210 mm Weight 28 kg 11 Maintenance and cleaning It is absolutely essential that the fixture is kept clean and that dust dirt and smoke fluid residues must not build up on or within the fixture Otherwise the fixture s light output will be significantly reduced Regular cleaning will not only ensure the maximum light output but will also allow the fixture to function reliably throughout its life A soft lint free cloth moistened with any good glass cleaning fluid is recommended under no circumstances should alcohol or solvents be used DANGER Disconnect from the mains before starting any maintenance work The front mirror and objective lens will require weekly cleaning as smoke fluid tends to building up residues redu
14. d iris for different beam diameters 7 7 Effect wheel This wheel has both hot and cold color temperature filters 8200 K and 5600 K Total numbers of color combinations are 36 Also wash light and UV effect are provided by the special effect wheel 7 8 3 facet rotating prism 3 facet prism rotating in both directions at different speed is situated at the special effect wheel 7 9 Focus Motorized focus enables the beam to be focused anywhere on stage 7 10 Dimmer Shutter Strobe Smooth 0 100 dimming is provided by the combined mechanical dimmer shutter unit This unit may also be used for strobe effect 1 10 flashes per second 7 11 Fan The VISION 575 is cooled by axial fan situated at the rear side of the lighting The speed of the fan of course the noice can be continuously reduced if very quiet performance is required By the control board using the FAnS function you can choose 4 types of low fan speed operating 1 HIGH high max speed of fan The cooling fan works on max speed max cooling 2 reG continuous controlling of the fan speed the fan automatically raises its speed in order to control inside temperature of the lighting if the temperature inside increases about certain level the low fan speed reduces the cooling of the lighting This cycle can repeat several times until the temperature inside is on suitable level 3 LoOF low speed Switch Off the lamp operating the fan keeps the adjus
15. ep step step proportional proportional proportional step proportional step proportional step proportional proportional proportional step step proportional step proportional step proportional step proportional 6 Addressing The control board on the front panel of the VISION 575 allows you to assign the DMX fixture address which is defined as the first channel from which the VISION 575 will respond to the controller If you set for example the address to channel 5 the VISION 575 will use the channel 5 to 20 for control Please be sure that you don t have any overlapping channels in order to control each VISION 575 correctly and independently from any other fixture on the DMX data link If two three or more VISION 575 are addressed similarly they will work similarly For address setting follow this procedure 1 Switch On the VISION 575 and wait until the fixture reset has finished rSt is flashing at the display 2 Press the Menu key in order to access the main menu Browse through the menu by pressing the and keys until the display shows A001 Confirm by pressing Enter key and the letter A will flash 3 Use the and keys to select the desired address 4 Confirm by pressing Enter or Menu to cancel Controlling After having addressed all VISION 575 you may now start operating these via your lighting controller Note After switching on the VISION 575 will automatic
16. ety reasons If this device will be operated in any way different to the one described in this manual the product may suffer damages and the guarantee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shock burns due to ultraviolet radiation lamp explosion crash etc 3 Description of the device function display ooo ooo O000 12 13 14 15 akhoOND Fastening screws Fixation screw for bracket Bracket Objective Mirror Front panel 6 72 8 9 10 DMX Output DMX Input Fuseholder Powercord Control board Control board 11 12 13 14 15 Display Menu button Enter button Up button Down button 4 Installation 4 1Fitting the lamp DANGER Install the lamps with the device switched off only Unplug from mains before To insert the lamp HMI 575 open the cover by loosening the fastening screws at the sides of the cover Do not install a lamp with a higher wattage A lamp like this generates temperatures the device is not designed for Damages caused by non observance are not subject to warranty Insert the lamp now Do not touch the glass bulb with bare hands during the installation Please follow the lamp manufacturer s notes Before you close the cover again make sure that the lamp is installed tightly into the lampholder system Reclose the housi
17. feature or Off if you don t wish this feature and press Enter to confirm or Menu to cancel and return to the main menu Tilt reverse This function allows you to invert the tilt movement Use the and keys to select On if you wish this feature or Off if you don t wish this feature and press Enter to confirm or Menu to cancel and return to the main menu Movement resolution By this function you can adjust the desired movement resolution 8 or 16 bit Use the and keys to select On if you wish the 16 bit high resolution or Off if you wish only 8 bit resolution and press Enter to confirm or Menu to cancel and return to the main menu Note If you adjust the 16 bit resolution the fixture will occupy 16 DMX channels if you adjust the 8 bit resolution the fixture will be operated by only 14 DMX channels Please check the DMX protocol Lamp On time This option enables you to read the total number of hours that the lamp has been powered On Press Enter or Menu to return to the main menu In order to reset the counter to 0 you have to hold the and button and press the Enter button Power On time By this option you can read the total number of hours that the VISION 575 has been powered On Press Enter or Menu to return to the main menu Switch On Off the lamp Use the and keys to select On if you wish the switch On the lamp or Off if you wish switch Off the lamp and press
18. function in order to write the calibration values to the memory EPROM and to make a reset in order to check the newly adjusted positions of the colour gobo and effect wheels When the reset of the fixture is finished the display will show the FCAL message Press Enter to repeat the calibration or Menu to return to the AdJ menu 2 Calibration via the external controller Press Enter and the and keys in order to display the following messages Col SGob EFEC rGob rotG calibration parameters Select one of them and press Enter Now you can calibrate the the colour gobo and effect wheel by your controller The DMX calibration protocol is described in the table DMX Calibration protocol are an U o o OO J oo0o3 0 TDOeNOnO 3 3030 lt 083 7 Senden priced 1o proton n 2 proton E proton z E protoooi 6 After having calibrated required functions press Enter to confirm or Menu to cancel and return to the menu without reset by the ArES function and use the ArES function in order to write the calibration values to the memory EEPROM and to make a reset in order to check the new adjusted positions of the colour gobo effect and rot gobo wheels and gobo indexing 1 9 Error and information messages HEAt This message appears if you try to switch on the lamp within 5 minutes after having switched it off the lamp is too hot The message will appear on the display if the lamp doesn t ig
19. lying around You endanger your own and the safety of others The minimum distance between light output and the illuminated surface must be more than 1 m Make sure that the area below the installation place is blocked when rigging derigging or servicing the fixture Always fix the fixture with an appropriate safety rope Fix the safety rope at the correct holes only Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened The lamp must never be ignited if the objective lens or any housing cover is open as discharge lamps may explose and emit a high ultraviolet radiation which may cause burns The maximum ambient temperature t 45 C must never be exceeded Otherwise the lamp is switched off and the fixture is out of operation for 5 minutes CAUTION The lens has to be replaced when it is obviously damaged so that its function is impaired e g due to cracks or deep scratches Operate the device only after having familiarized with its functions Do not permit operation by persons not qualified for operating the device Most damages are the result of unprofessional operation CAUTION The lamp has to be replaced when it is damaged or deformed due to the heat Wait at least 15 minutes before remowing the lamp Please use the original packaging if the device is to be transported Please consider that unauthorized modifications on the device are forbidden due to saf
20. ng and tighten the fastening screws Before striking the lamp reset the LAti counter in the main menu of the Control Board by pressing the and buttons at the same time and then confirming with the Enter button Do not operate this fixture with opened housing cover 4 2 Inserting Exchanging rotating gobos DANGER Install the gobos with the device switched off only Unplug from mains before If you wish to use other forms and patterns as the standard gobos or if the gobos are to be exchanged remove the fixation ring with an appropriate tool Remove the gobo and insert the new gobo Press the fixation ring together and insert it in the front of the gobo CAUTION Never unscrew the screws of the rotating gobo as the ball bearing will otherwise be opened 4 3 Rigging the fixture Danger of fire When installing the device make sure there is no highly inflammable material decoration articles etc in between a distance of min 0 5 m The VISION 575 can be installed in any position without altering its operation characteristics Install a safety wire that can hold at least 10 times the weight of the fixture Never use the carrying handles for secondary attachment Make sure that the device is fixed properly Ensure that the structure to which you are attaching the projectors is secure For fixing the projectors use the hole provided in the bracket The hole in the adjustable mounting bracket has a diamete
21. nite within 28 seconds The VISION 575 will store this information and automatically ignite the lamp when the 5 minutes period has expired LAEr The ignition of the lamp is seven times unsuccessful the HEAt message appeared six times before and the display shows LAEr meaning that the lamp could be damaged or even missed the fixture is overheating this can occur if the ambient temperature is 45 C or more or there could be a failure on the ignitor or ballast Please place or replace the lamp check the ambient temperature or contact your dealer if the situation was not caused by the lamp FAn The message informs you that the fixture was overheating and switched off This message will appear on the display if the fan speed operating LOOF was selected MbEr This messsage informs you that the main PCB does not communicate correctly with the Control Board CoEr color wheel error This messsage will appear after the reset of the fixture if the magnetic indexing circuit malfunctions sensor failed or magnet missing or the stepping motor is defective or its driver circuit on the main PCB The color wheel is not located in the default position after the reset SGEr static gobo wheel error This messsage will appear after the reset of the fixture if the magnetic indexing circuit malfunctions sensor failed or magnet missing or the stepper motor is failed or its driver circuit on the main PCB The static gobo wheel is not after
22. old before re striking For this reason you have to wait 5 minutes max speed of fan must be adjusted after having switched Off the lamp before you can switch it back On again If you try to switch On the lamp within 5 minutes after having switched it Off the VISION 575 will store this information and automatically ignite the lamp when the 5 minutes period has expired The message HEAt will appear on the control board display If the ignition of the lamp is seven times unsuccessful on the display will appear LA Er meaning that the lamp could be damaged or even missed or there could be a failure on the ignitor or ballast 7 3 Colour wheel The SC 780 has one colour wheel with 12 color positions 11 of these with dichroic colors and the last one open The wheel can be positioned between two adjacent colors in any position It is also possible to rotate the color wheel continuously at different speed Rainbow effect 7 4 Static gobo wheel This wheel has 8 metal gobos 2 dichroic gobo 1 multicolor dichro gobo open position Multicolor dichroic gobo containing C M Y colors is mixable with color wheel especially with cyan magenta and yellow colours in order to obtain several different multicolor beams 11 7 5 Rotating gobo wheel 1 metal gobo 4 glass gobos and 1 dichroic gobo rotating in both dirrections indexable rotating gobo wheel cont rotation slow to fast The rotating gobos are interchangeable 7 6 Iris Motorize
23. r of 10 mm For overhead use fit a safety chain or cord 4 4 Connection to the mains Connect the fixture to the mains with the enclosed power plug The earth has to be connected The occupation of the connection cables is as follows Brown Live Blue Neutral Yellow Green Earth 4 5 DMX 512 connection connection between fixtures The wires must not come into contact with each other otherwise the fixtures will not work at all or will not work properly 120 Q lt lt DMX 512 i Only use a stereo shielded cable and 3 pin XLR plugs and connectors in order to connect the controller with the fixture or one fixture with another Occupation of the XLR connection DMX output DMX input XLR mounting socket XLR mounting plug 1 Ground 1 Ground 2 Signal 2 Signal 3 Signal 3 Signal If you are using the standard DMX controllers you can connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX chain If you wish to connect DMX controllers with other XLR outputs you need to use adapter cables Building a serial DMX chain Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture Always connect one output with the input of the next fixture until all fixtures are connected Caution At the last fixture the DMX cable has to be te
24. rminated with a terminator Solder a 120 Q resistor between Signal and Signal into a 3 pin XLR plug and plug it in the DMX output of the last fixture 5 DMX PROTOCOL hannel Channel Value Type of control 16 bit 8 bit E TTT ozs 255 E TTT control of the pan movement oee Tilt a 0 255 Coarse control of the tilt movement proportional Pan fine ee 255 Fine control of the pan movement proportional Tilt fine 0 255 Fine control of the tilt movement proportional Speed of PAN TILT movement 0 Max speed step 249 Min speed proportional 250 255 Max speed black out while PAN TILT moving step Lamp on off reset fan speed control From max speed of fan to min speed of fan proportional Lamp on reset step No function step Lamp off after 3 sec step No function step Colours Open white proportional Turquoise proportional Red proportional Cyan proportional Green proportional Magenta proportional Light blue proportional Yellow proportional Green proportional Pink proportional Blue proportional Orange proportional Forwards rainbow effect from fast to slow proportional No rotation step Backwards rainbow effect from slow to fast proportional Static gobos Open step Forward gobo wheel rotation from fast to slow proportional No rotation step Backward gobo wheel rotation from slow to fast proportional Gobo 1 multicolor dichro step Gobo 2 dichro step Gobo 3 dichro step Gobo 4 step Gobo 5 step Gobo 6 step
25. s Personality Display SHADED m og zo Pan reverse cern JEF m i L I n Tilt reverse res it TE Movement Cre Gn resolution 1 GFF Lamp on 1 oo on automatically Lee GFF Automatic blackout wt co Gn of display oe ot DEF Display intensity gd ink e240 60 sofa a m Lamp Off via DMX dL HE OFF Low fan speed sie r operating EAn 5 CF Lo i Adjusting the default positions of colour gobo and effect wheels By this function you can calibrate and adjust the colour and CMY to their standard right positions Use the and keys to browse through the adjusting menu the display shows step by step these messages PAn Tilt SPEd Col SGob EFEC rotP rGob rotG IriS Foc Stro dimr FCAL by which you can adjust the fixture to the required desired position 0 255 before the function calibration Then when the positioning is finished use the last FCAL function Fixture calibration 0 255 0255 0 255 0 255 0 255 17 1 Calibration via the control board Press Enter and the and keys in order to display the following messages Col SGob EFEC rGob rotG for very smooth function calibration Select one of them press Enter and use the and keys in order to adjust their right value from 0 to 255 Then press Enter to confirm or Menu to cancel and return to the menu This can be repeated for each calibration parameter if it is required When the calibration is finished it is necessary to use the ArES
26. ted low speed until the temperature exceeds max inside temp Then the VISION 575 automatically switch Off the lamp 4 loHi low high speed of the fan operating the fan keeps the adjusted low speed until the temperature exceeds max inside temp of the fixture then the VISION 575 automatically switch from low to high the fan speed 8 Control Board The control board situated on the front panel of the VISION 575 offers several features You can simply set the lighting address read the number of lamp or unit hours switch On and Off the lamp run test show make a reset and also use special functions for manual demo and service purposes The main menu is accessed by pressing the Menu key press this one so many times until the display shows message A001 with actually stored address Browse through the menu by the pressing and keys the display shows step by step these messages A001 rPAn rTilt 16br Lati Poti LAMP tESt rESE SPEC Press Enter if you wish to select one of them The functions provided are described in the following sections and the function hierarchy is shown below 8 1 Main functions DMX 512 Address settings The letter A flashes Use the and keys to select required address 001 497 and press Enter to confirm or Menu to cancel and return to the main menu Pan reverse This function allows you to invert the pan movement Use the and keys to select On if you wish this
27. the reset in the default position rGEr rotating gobo wheel error This messsage will appear after the reset of the fixture if the magnetic indexing circuit malfunctions sensor failed or magnet missing or the stepper motor is failed or its driver circuit on the main PCB The rotating gobo wheel is not after the reset in the default position IGEr rotating gobo indexing error This messsage will appear after the reset of the fixture if the magnetic indexing circuit malfunctions sensor failed or magnet missing or the stepper motor is failed or its driver circuit on the main PCB The rotating gobo is not after the reset in the default position EFEr effect wheel error This messsage will appear after the reset of the fixture if the magnetic indexing circuit malfunctions sensor failed or magnet missing or the stepper motor is failed or its driver circuit on the main PCB The effect wheel is not after the reset in the default position FtEr This error message informs you that the fixture was overheating occured if the ambient temperature is 45 C or more and that the relay switched off the lamp This message will appear on the display until the temperature will be on a suitable level then the display will show the HEAf message meaning the lamp is too hot explanation see above SnEr This message appears if the lamp lighting sensor is failed PoEr This message will appear if the fixture was shortly disconnect from the m
Download Pdf Manuals