Home
MD60LOG USER MANUAL
Contents
1. As indicated above the GPS module provides the position at regular intervals of time update frequency not necessarily in correspondence to the finish line It often occurs that the system receives the position in the P1 point before the finish line and P2 after the finish line The time correction on the lap read comes about automatically considering the interpolation between these two points The basic hypothesis on which the above mentioned calculation is based is that the speed of the vehicle is constant Therefore if the speed between points P1 and P2 is constant two modules with different update frequencies will obtain the same performance in the calculation of the lap time FINISH LINE P1 POINT P2 POINT MD60LOG User Manual rev 05 Copyright 2010 GET by Athena Evolution srl All rights reserved 1 MDGOLOG KIT The MD60LOG system is supplied with L O TT Packing MD60LOG SIZE AA ALKALINE Batteries CD containing the software and documentation relative to the instrument USB Cable Case Do not use batteries different than those indicated In case of the contrary the instrument could become irreparably damaged Use only SIZE AA ALKALINE batteries or SIZE AA Ni Mh RECHARGEABLE BATTERIES with nominal capacity
2. Ea a a a A A A a aa a a a A LINE 3 FL LINE 2 SPLIT 2 rss a a A a x x ie i I 11 2 CREATION OF A CUSTOM TRACK IN LINEAR MODALITY If you want create a custom track in LINEAR modality suitable for open circuits like car bike dragster competitions please verify that the TRACK MODE option in OPTIONS menu is set as LINEAR Please note the starting point position will be automatically calculated when the vehicle starts running Beware if the first split point is too near the starting point the MD60 LOG can t be display the first split time After this check follow the procedure described at the next chapter 11 2 1 Starting line and intermediate times definition In the event that the track desired is not in the unit s library or you wish to create a new one with different settings from those present in the memory of the MD60 proceed in the following manner e Make sure that there is adequate satellite coverage the unit must be locked on to at least 5 satellites e From the CHRONO screen briefly pressing the S SET button enter the main menu and select the submenu TRACK pressing the S button briefly Scroll the page with the ARROW button and briefly pressing the S SET button select the item CREATE NEW The LINE 1 item will appear on the CHRONO screen indicating the create track mode CURRENT TRACK LAP KPH VIEW TIM
3. In the event that you would like to record a new session and the memory of the MD60LOG is exhausted the unit will request the deletion of all of the previous sessions recorded Download the data to your PC before carrying out this operation or you will lose all of it MD60LOG User Manual rev 05 Copyright 2010 GET by Athena Evolution srl All rights reserved In the event that this situation arises the unit will display the following screen s DATE TIME LOGGER OVERWRITE ALL SESSION 01 15 05 12 38 lt lt EXIT L p O TT The selection by pressing the S button briefly on the items NO or YES will produce the following effects e NO the unit returns to the CHRONO screen CURRENT TRACK LAP KPH MONZA 00D ooo e YES all of the sessions saved to the unit s internal memory will be deleted A new acquisition will be started up OVERWRITE ALL SESSION NO MD60LOG User Manual rev 05 Copyright O2010 GET by Athena Evolution srl All rights reserved 10 3 TRACK MENU The TRACK menu enables the user to access the functions for loading creating or deleting the tracks present in the internal library of the MD60LOG CURRENT TRACK LAP KPH VIEW TIMING REPORT MONZA o jooo DATA LOGGING n e 3 i TRACK 00 00 00 j OPTIONS OPTIONS mis A a a lt lt EXIT lt lt EXIT a pouse m Z G U T DELETE TRACK lt lt EXIT The functions available in this menu are e
4. e The options available selectable by way of a brief pressing of the S button are YES enables the track created to be given a name and then saved to the unit s library SAVE CREATED TRACK TRACK NAME MUGELLO 4 Set the name pressing the ARROW to scroll the different alphanumeric characters and briefly press the S button to confirm the character entered Continue until the name is completed To exit from the setting of the track name briefly press the S SET button on the special character visible among those used for the composition of the name of the track In the case of a name chosen that is already present in the library the track will be saved adding a number at the end of the name selecting for example setting MUGELLO a name already present in the library the track will be saved as MUGELLO1 NO turns off the unit without saving the track created SAVE CREATED TRACK SAVE CREATED TRACK s A MD60LOG User Manual rev 05 Copyright 2010 GET by Athena Evolution srl All rights reserved L O TT m Z G U I 11 4 SUGGESTIONS FOR THE CREATION OF A CUSTOM TRACK The finish lines set have a transversal length in the forward direction determined by the value of the parameter FL LENGTH see chap 10 4 Factory setting is equal to 30 metres 15 m on the right hand side in the forward direction and 15 m on the left side We suggest that the finish lines not be placed in
5. MDGOLOG USER MANUAL By Athena Evolution MD60LOG User Manual revision 05 Release FW 3 5 Copyright 2010 GET by Athena Evolution All rights reserved The contents of this document or any part of it may not be reproduced transferred distributed or memorised in any form whatsoever without the written permission of GET by Athena Evolution s r l m Z G U I GET reserves the right to modify the content of this manual without prior notice The GPS positioning system is probabilistic and is directly linked to the proper reception of the signals on the part of the receiver In case of faulty positioning electromagnetic or environmental disturbances the precision of the data provided by the device cannot be guaranteed MD60LOG User Manual rev 05 Copyright 2010 GET by Athena Evolution srl All rights reserved 1 MOSELA atasca 3 2 MAIN FEATURES AND FUNCTIONS olii 4 3 FOR PROPER USE sucedio ro a ma olli aduta muti a aia ila aga aa 5 4 WARNINGS tai 5 5 CHRONO MODE AND DATA LOGGER MODE FOR THE MD60LOGi iii 5 6 PREPARATION OF THE DEVICE sian alitnaso dope tati teda dia aiia iaaii iaon diideri niina iiinn 6 7 LAYOUT OF THE COMMANDS AND SIGNALS ON THE MD60LOG i 7 7 1 MD60LOG TIMES VISUALISATION SCREEN CHRONO PAGE i 7 8 USE OF THE BUTTONS ON THE MD60LOG ii 8 9 USE OF TAE NBbO0EO Gioie a roi 8 9 1 FIRST TURNEONOP TRE UNIT alt a imaami 8 9 2
6. LOAD FROM LIBRARY enables the selection of one of the tracks present in the unit s library Pressing the S SET button briefly when the item is highlighted by the cursor the screen with the tracks present in the library of the MD60LOG will be visualised Scroll the items by pressing the ARROW button and select the track desired pressing the S SET button briefly the unit will load the track and return to visualise the CHRONO page CREATE NEW ALBACETE DELETE TRACK lt lt EXIT ALCARAZ ALCARAZ ASSEN ASSEN BINETTO BINETTO CURRENT TRACK LAP KPH ALBACETE e e CREATE NEW enables one to go on to create a customised track to be entered into the unit s track library Pressing the S SET button briefly when the item is highlighted by the cursor access to the create tracks function will be given see chap 11 of this manual e DELETE TRACK enables one to delete a track entered in the unit s track library Briefly pressing the S SET button when the item is highlighted by the cursor access to the list of tracks will be given by way of the use of the ARROW button to scroll the items and the S button for the selection it is possible to remove the unwanted track from the unit s memory e lt lt EXIT enables the return to the CHRONO page of the unit without making any changes to the track offered in the start menu of the unit The selection of this function comes about briefly pressing the S SET button when the item is high
7. O TT CURRENT TRACK LAP KPH MONZA jo ooo DATA LOGGING TRACK OPTIONS lt lt EXIT 10 1 VIEW TIMING REPORT MENU The VIEW TIMING REPORT menu enables read access of the reports of the sessions archived in the internal memory of the unit CURRENT TRACK LAP KPH MONZA 00D o0 BEST 01 32 54 TRACK 01 59 79 OPTIONS 01 47 69 lt lt EXIT Pressing the S SET button briefly on VIEW TIMING REPORT accesses the list of the sessions archived by number S date DATE creation time TIME and best lap realised BEST Ten memory positions are available selectable by way of the ARROW button Once used up the system overwrites the eleventh into the first position The maximum number of laps per session that may be memorised is 99 To view reports from the unit follow the procedure below e Enter the VIEW TIMING REPORT menu e Move around the sessions list using a brief pressure on the ARROW button once the cursor has highlighted the desired item press the S SET button to visualise the report TIME RETURN TO CHRONO 01 32 54 01 59 79 01 47 69 01 37 59 15 47 01 59 79 16 36 01 47 69 The L column indicates the number of the lap of the session currently visualised the TIME column indicates the lap time the TSPD column indicates the maximum speed achieved It is possible scroll the lines of the report by pressing the ARROW button Two options a
8. User Manual rev 05 Copyright O2010 GET by Athena Evolution srl All rights reserved L O TT Athena Evolution s r l Via delle Albere 8 36045 Alonte VI Italy
9. of the intermediate positions If just the FINISH LINE is needed it is enough to press the S SET button when the display visualises the message LINE 1 in this condition upon the next passage over the finish line the instrument will begin to read the lap times If only 2 split points and a finish line are needed user can press the S button when the display show LINE3 LOAD FROM LIBRARY CREATE NE DELETE TRACK lt lt EXIT LINE 3 FL da i a i o i a e iia LINE 2 SPLIT 2 MD60LOG User Manual rev 05 Copyright 2010 GET by Athena Evolution srl All rights reserved 11 3 SAVING A CUSTOM TRACK After having created a track it is possible to proceed with its saving in the internal library of the MD60LOG The function is automatically activated when the lap timer stops only if the procedure indicated in chap 11 1 and 11 2 has been performed properly e From the CHRONO screen when chronometer stopped please remember that the unit mustn t be in DATA LOGGER mode the track saving page will be displayed automatically CURRENT TRACK LAP KPH SAVE CREATED TRACK
10. signal alarm Automatic GPS search for the track if automatic track search is activated Possibility of creating and memorising any type of track Automatic memorisation of the test run session archived by date and time Recording of sessions carried out for later PC data analysis Lap times report Intermediate times report Maximum 4 Maximum speed report Automatic vehicle speed acquisition start up only with display on Settable acquisition threshold for start up Settable chronometric measurement display times USB port for PC connection Operational autonomy 6 hours continuous use with new batteries of the type recommended ref Chapter 1 in this document GET by Athena Evolution reserves the right to implement new functions over time All of the information relative to this and other GET products by Athena Evolution are available on the internet site www getdata it MD60LOG User Manual rev 05 Copyright 2010 GET by Athena Evolution srl All rights reserved 3 FOR PROPER USE Use of the MD60LOG requires the observance of the following guidelines Use the instrument outdoors Remove the transparent protective film placed on the display so as to avoid the accumulation of electrostatic charges on the upper part of the instrument Turn on the device and position it in an open area Avoid any obstacles that may impede the reception of the GPS signals Wait for from 2 to 5 minutes for the lock on and reception of at le
11. that the instrument in its lateral perimeter comes into contact with vibrating parts of the vehicle This condition could bring about continual stress to the internal batteries causing shutdowns For application on motorcycles it would be preferable to locate the instrument on the upper fork plate Faulty installation could prejudice the proper operation of your MD60LOG MD60LOG User Manual rev 05 Copyright 2010 GET by Athena Evolution srl All rights reserved BEST LAP LED SELECTION BUTTONS ON BEST LAP LED INTEGRATED SET GPS ANTENNA bra Www getdceata it DISPLAY OFF pico LOW BATTERY ALARM LED ARROW BATTERY 7 1 MD60LOG TIMES VISUALISATION SCREEN CHRONO PAGE The fields on the CHRONO page of the MD60LOG provide the driver with the following data Field 1 Lap time Field 2 Number of satellites seen by the system Field 3 Current date and time notification for the recording of the session under way Field 4 Battery level indicator Field 5 Speed expressed in km h or mp h Field 6 Number of laps driven Field 7 User settable field enables visualisation of information relative to the track CURTRACK best lap time BESTIME last lap time LASTIME This message appears in field 1 when the GPS system is not available in this condition it is not possible to perform chronometric acquisitions or measurements MD60LOG User Manual rev 05 Copyright 2010 GET by Ath
12. ING REPORT DATA LOGGING 00 E 00 00 OPTIONS i OPTIONS gt a Ml 08 23 05 14 40 08 LOAD FROM LIBRARY DELETE TRACK lt lt EXIT Fo aan sone MD60LOG User Manual rev 05 Copyright 2010 GET by Athena Evolution srl All rights reserved m Z G U I Upon passing the first intermediate time desired in the case of closed or open circuits press the ARROW button the unit will record the GPS coordinates of the point just defined and will prepare to memorise the next showing the message LINE 2 The length of the transversal finish line set will be defined by the value associated with the parameter FL LENGTH see chap 10 4 Upon passing the next intermediate point press the ARROW to memorise its position The unit will prepare for the next intermediate line displaying the message LINE3 Itis possible to continue with the same procedure until arriving at the last intermediate line available LINE4 Once the finish line position LINE5 has been defined by pressing the S SET button the unit will then return to the time measurements page Make sure that the chrono start running by passing the speed threshold defined on START SPEED option this condition its necessary to allow the saving custom track procedure In these conditions it is possible to start a test session or to save the track just created in the unit s archive see chap 11 3 NOTE during the creation of the track it is not necessary to define all
13. LATER TURNON OF TRE UNIT nadia 9 9 2 1 Turning on the unit with a track already properly SEt i 9 9 2 2 Turn on of the unit and selection Of a track nn nnnanna nn nnnennnenna 9 10 MD60LOG MENUS AND FUNCTIONS ii 11 10 1 VIEW TIMING REPORT MENU iii 11 10 2 DATA LOGGING FUNG TION siii idioti 12 10 3 TRA R EMAKS io amm ame a tn 14 10 4 MEND OPTIONG EMA EES iti 15 11 CREATION OF A CUSTOM TRACK lare 18 11 1 CREATION OF A CUSTOM TRACK IN LOOP MODALITY anna nnnnnnnnnn annan 18 11 1 1 Starting line and intermediate times definition nn nnne n 18 11 2 CREATION OF A CUSTOM TRACK IN LINEAR MODALITY i 19 11 2 1 Starting line and intermediate times definition nan naneena 19 11 3 SAVING A CUSTOM TRACK celentano 21 11 4 SUGGESTIONS FOR THE CREATION OF A CUSTOM TRACK 22 11 5 UPDATING THE TRACK LIBRARY lt ositarcionmios t tiitlile kaatet ka ats 22 12 FIRMWARE UPDATING cis das 23 13 OPTIONAL nipote nre ai UO ADE E amil alumisi 24 13 1 HANDLEBAR SUPPORT KIT 24 14 TECANICAL SPECIEICATIONS coliaea ori rio 25 Dear Client Thank you for having chosen a product from the DATA ACQUISITION AND ANALYSIS SYSTEMS line from GET by Athena Evolution Certain that our passion and experience will be able to assist you in successfully expressing yourself in any competition in which you may wish to participate we invite you to read this
14. apters MD60LOG User Manual rev 05 Copyright 2010 GET by Athena Evolution srl All rights reserved 9 2 LATER TURN ON OF THE UNIT The next time that the MD60LOG is turned on the unit requires the user to with the TRACK SEARCH option set on MAN see chap 10 4 of this manual or with current track not present in the internal library of the instrument perform certain preliminary operations I 0 mua O The following chapters illustrate the behaviour to follow in possible situations that a user may encounter lt 9 2 1 Turning on the unit with a track already properly set Under normal use of the unit each time that it is turned on with the TRACKING MOD option set on MAN see chap 10 4 of this manual or with current track not present in the internal library of the instrument the display will visualise the following screen PROPOSED TRACK ITEM SELECTED SELECTED TRACK In this condition it is necessary to perform the setting of the track or to create a new one if the track proposed by the instrument corresponds to the track desired the OK item is selected push S SET briefly to access the CHRONO page on the MD60LOG CURRENT TRACK LAP KPH MONZA a 00 00 00 In this condition the instrument is ready to be used either in the CHRONO or the DATA LOGGER mode see chap 5 of this manual To learn the different start up methods and the other possibilities offered by the MD60LOG refer to chap 10 of this man
15. ast 5 satellites Beyond this time try turning the unit off and then turning it back on again Once the message NO SAT disappears from the display the unit is ready for use In case the system freezes up it may be necessary to remove the batteries for a brief time 10 15 seconds and then replace them so as to proceed with a reset of the entire system Do not tamper with the device in case of malfunction Consult your reseller or the GET technical service centre It is strongly recommended that discharged batteries not be left inside of the MD60LOG for long periods of time For proper disposal of your MD60LOG remove the batteries 5 CHRONO MODE AND DATA LOGGER MODE FOR THE MDGOLOG The MD60LOG that you have purchased operates in two possible modes CHRONO The instrument works as if it was a normal chronometer measuring lap times and then showing them in the VIEW TIMING REPORT menu window See chap 10 1 of this manual There may be a maximum number of 10 sessions with 99 laps each Once the memory has run out any new sessions are memorised in the place of the oldest present in memory The report with the data relative to the sessions archived in memory may be downloaded to a PC using the included USB port and the GATE LITE software The file obtained may not be analysed with the MX2 LITE or MX2 analysis software but may be visualised with any text program such as One Note or Microsoft Word DATA LOGGER The instru
16. at least 2700mAh DO NOT OPEN THE UNIT BY UNSCREWING THE SIX CLOSING SCREWS ON THE BOTTOM OF THE BATTERY COMPARTMENT OPENING OR TAMPERING WILL BE INDICATED BY THE BREAKAGE OF THE INTERNAL SEALS AND WILL PREJUDICE ANY FORM OF GUARANTEE OPENING OF THE DEVICE BY INEXPERT PERSONNEL COULD CAUSE THE DAMAGE OR BREAKAGE OF PARTS 5 e DR ce A PANI o ste A lt P i f Lo VI i JA ON GET www panela ore 4 ATTENTION the autonomy of the instrument is determined by the guality of the batteries used MD60LOG User Manual rev 05 Copyright 2010 GET by Athena Evolution srl All rights reserved m Z G U T MAIN FEATURES AND FUNCTIONS IP65 protection grade anti shock plastic casing Lap time visualisation average error 1 tenth of a second Sector time visualisation in relative mode for the single sector or absolute LED notification of the best lap or sector time Memorisation of the best sector times Visualisation of the speed in kilometres per hour or miles per hour user setting options Visualisation of the number of laps during a test run Visualisation of the current track in a settable field Visualisation of the best lap time obtained in a settable field Visualisation of the date and time with automatic GPS updating Visualisation of the number of satellites detected by the system Visualisation of the battery level Visual LED low battery level
17. ation relative to the orbit and the hour signal ephemeris messages enabling the receiver to carry out the calculations necessary to determine the position on the Earth s surface MD60LOG User Manual rev 05 Copyright 2010 GET by Athena Evolution srl All rights reserved L O TT m Z G U T One of the parameters that characterise GPS modules is the update rate expressed in Hz Hertz with this information the number of times per second that the device is able to detect terrestrial latitude and longitude coordinates is indicated In other words a module with an update rate of 1 Hz will detect the position once per second whilst one with a frequency of 5 Hz will provide in the same time frame 5 different coordinates this translates into a higher precision for the acquired trajectories The MD60LOG chronometer is capable of reading the times and the interval times on the lap thanks to a finish line distinguished by precise GPS coordinates The above mentioned lines must be set out so that they intersect the track see figure below when the vehicle passes the line the instrument is in this manner able to perform a calculation of the time for the lap in the case that this has to do with the FL that is the actual finish line of the track or for intermediate times in the case that a SPLIT line is crossed FINISH LINE
18. ctricos y electr nicos RAEE Legislaci n referida a la eliminaci n de residuos de aparatos el ctricos y electr nicos que se aplica en la Uni n Europea y en los otros pa ses europeos con servicio de recogida selectiva El s mbolo del contenedor de basura tachado presente en el producto o en el embalaje indica que el producto no se puede tratar como residuo dom stico sino que se debe eliminar por separado y se debe entregar a un centro de recogida autorizado para el reciclaje de los residuos de aparatos el ctricos y electr nicos o se debe devolver al revendedor en el momento de la compra de un nuevo producto equivalente Haciendo que el producto se elimine de una manera compatible con el medio ambiente se evitan las potenciales consecuencias negativas sobre el mismo y sobre la salud del hombre y se favorece el nuevo uso o el reciclaje de los materiales que componen el aparato La eliminaci n incontrolada del producto por parte del usuario implica la aplicaci n de las sanciones administrativas previstas por la legislaci n vigente Para la aplicaci n correcta de la legislaci n los fabricantes participan en sistemas colectivos que tienen la funci n de organizar y gestionar los sistemas de recogida de los RAEE procedentes n cleos dom sticos Para mayor informaci n dirigirse a la oficina de la ciudad de residencia encargada del servicio de eliminaci n de desechos urbanos o a la tienda donde se adquiri el producto MD60LOG
19. ena Evolution srl All rights reserved L O TT m Z G U T 8 USE OF THE BUTTONS ON THE MDGOLOG Each button is set up for two kinds of use brief pressure and prolonged pressure According to the length of time of the pressure on the buttons different commands may be issued e Toturnon the unit push for over two seconds the S SET button e To turn off the device or quickly scroll the menus push and hold down the ARROW button e To enter in the MAIN MENU or in the SUBMENUS briefly press the S SET button e To scroll through the MENU items press briefly the ARROW button e Toconfirm a setting briefly press the S SET button USE OF THE MD60L0G Before using the device it is strongly recommended that this manual be read carefully Trying out each of the functions described below you will quickly gain confidence with the use of the unit NOTE for ease of use the following manual describes the menus and the relative items in English 9 1 FIRST TURN ON OF THE UNIT When turning on the unit for the first time it will ask that the system language be set select with the ARROW button the language desired and then confirm by pressing the S button ENGLISH lt lt EXIT FRANCAIS NOTE The language is requested even in the case of a RESET of the instrument see chapter 10 4 of this manual After setting the language it will be necessary to follow what is found in the following ch
20. ent will display a screen with the list of any sessions present in memory and the REC SESSION function If one intends on recording a session press the S SET button when the item REC SESSION is highlighted by the cursor the instrument will return to the CHRONO page beginning to record The user may at any moment decide to exit tte DATA LOGGER menu pressing the S SET button when the lt lt EXIT item is highlighted by the cursor MEMORY RESERVE INDICATOR BAR 01 15 05 12 38 lt lt EXIT A i t a 2 e ee Mt SESSION NUMBER NOTE When beginning to record a session the data present in field 3 GPS date and time these are substituted by the indication of the current session number ex SESSION 2 and by the memory reserve indicator bar ATTENTION SESSION RECORDING IS AVAILABLE ONLY WHEN THE INSTRUMENT PROPERLY RECEIVES AT LEAST 5 GPS SATELLITES e Select the REC SESSION item with the ARROW and confirm the choice with the S SET button the instrument goes to the screen displaying times and the message REC in the date time field will indicate that the unit is in recording mode The field will darken progressively to indicate the level of reserve internal memory In the event that the memory in the unit was to fill up tte MEMFULL message will appear in field 3 and recording will be interrupted e To stop recording of the session press the ARROW button the item REC disappears and in its place the current date and time appear again
21. fter this check follow the procedure described at the next chapter 11 1 1 Starting line and intermediate times definition In the event that the track desired is not in the unit s library or you wish to create a new one with different settings from those present in the memory of the MD60 proceed in the following manner Make sure that there is adequate satellite coverage the unit must be locked on to at least 5 satellites From the CHRONO screen briefly pressing the S SET button enter the main menu and select the submenu TRACK pressing the S button briefly Scroll the page with the ARROW button and briefly pressing the S SET button select the item CREATE NEW The LINE 1 item will appear on the CHRONO screen indicating the create track mode CURRENT TRACK LAP KPH DATA LOGGING 00 00 00 cs LOAD FROM LIBRARY Fo ao zione Upon passing the first intermediate time desired in the case of closed or open circuits press the ARROW button the unit will record the GPS coordinates of the point just defined and will prepare to memorise the next showing the message LINE 2 The length of the transversal finish line set will be defined by the value associated with the parameter FL LENGTH see chap 10 4 Upon passing the next intermediate point press the ARROW to memorise its position The unit will prepare for the next intermediate line displaying the message LINE3 It is possible to continue with the same procedure until a
22. ing reduces the duration of the batteries PWR OFF MIN briefly pressing the S SET button in the field POWER OFF MINS it is possible to set the automatic shut off time for the MD60LOG The values selectable by way of the ARROW button are from 00 to 10 with increments of 1 Set the value desired confirming by briefly pressing the S SET button Example setting 00 the unit will not turn itself off automatically Selecting 05 the unit will turn itself off automatically after having detected an absence of activity for more than five minutes MD60LOG User Manual rev 05 Copyright 2010 GET by Athena Evolution srl All rights reserved e TRACK SEARCH briefly pressing the S SET button in the field TRACK SEARCH it is possible to activate deactivate the automatic recognition of the track by way of the GPS positioning The values selectable by way of the ARROW button are AUTO In this mode the MD60LOG once locked onto the GPS system satellites will automatically select the track without requesting the setting upon turn on see chap 9 2 ATTENTION this option may only be used if the track is in the unit s library In case there is more than one track with the same GPS coordinates ex 04 MUGELLO GP and 05 MUGELLO SBK the track loaded will be the first on the list ex 04 MUGELLO GP L O TT MAN Select this option if you want to load the track manually Confirmation of the value set comes about by way of the brief
23. lighted by the cursor MD60LOG User Manual rev 05 Copyright 2010 GET by Athena Evolution srl All rights reserved 10 4 MENU OPTIONS The OPTIONS submenu enables the modification and customisation of the functions of the device CURRENT TRACK LAP KPH VIEW TIMING REPORT DATA LOGGING ENGLISH MONZA oo 000 DO A TRACK 00 00 00 OPTIONS M 0 4 0 er a lt lt EXIT 08 23 05 14 40 08 CURTRACK ABSOLUTE KEEP TIME 010 TIMEZONE 02 RESET UNIT SPEED KPH The options selectable by way of the ARROW and S buttons are e INFO FIELD Briefly pressing the S SET button on the option INFO FIELD it is possible to customise the visualisation of the data on field 7 of the time visualisation screen on the MD60LOG during the CHRONO or DATALOGGER modes The options selectable by way of the ARROW button are CURRENT TRACK name of the track loaded and used by the unit BEST TIME visualisation of the best time in the session LAST TIME visualisation of the last time in the lap just finished To confirm the parameter set again briefly press the S SET button e SEC SPLIT Briefly pressing the S SET button on the option SEC SPLIT it is possible to decide on the visualisation method for the intermediate times upon passing the SPLIT sectors of the track loaded The options selectable by way of the ARROW button are ABSOLUTE upon passing of the intermediate sectors the time will be displayed counting from
24. line batteries Standard standby autonomy 2 months with alkaline batteries 4 MB internal flash memory On board button turn on Graphic transflective positive FSTN 128x96 pixel Display with user activated back light GPS Module at 5Hz high sensitivity 159 dBm with integrated antenna Two on board buttons for unit management Three LEDs for signals Dimensions length X width X depth in mm 108 X 55 X 30 Weight batteries not included 150 g FUNCTIONS Automatic shut down in absence of external input with settable time out Battery level visualisation Energy saving function may be set on the unit Automatic management of the time setting the correct time zone in the instrument Track library pre loaded Creation of custom tracks by way of quick setting of the finish lines and of the intermediate splits max 4 Saving of the tracks custom created by the user in the internal memory Automatic Selection by way of the GPS coordinates of the track if present in the library GPS lap and intermediate time calculations without sensors on the edges of the track Top speed and best lap reports Memorisation of 10 sessions and 99 laps per session Speed display in Kph or Mph Visualisation of the number of satellites detected by the system LED indication of the best lap Alarm and low battery display Alarm and no satellite lock with display messages GPS MODULE SPECIFICATIONS GPS Module with 32 parallel channels Update rate frequenc
25. manual confident that it will assist you in the use of your new GET by Athena Evolution device The MD60LOG device thanks to GPS technology enables real time recording and visualisation of lap times partial times and speed without the use of external sensors Featuring great ease of use and flexibility the MD60LOG contains memorised in it finish lines and sectors for the major Italian and Spanish racetracks and enables the creation and customisation of any track The automatic recognition of the track will make the use of this device simple and intuitive The GPS Global Positioning System System on which your GET instrument is based uses a spherical positioning system to determine the point where the receiver of the satellite signals is By way of the measurement of the time needed for a radio signal to cover the distance between satellite and receiver and by knowing the precise position of at least 4 satellites it is possible to determine the position in 3D space of the same receiver The constellation of 24 satellites set in orbit at a 55 inclination with respect to the plane of the equator is at an altitude of between 18 000 and 20 000 km and a 12 hour orbit The satellites transmit signals at carrier frequencies of 1 2 and 1 5 GHz to avoid possible errors derived from atmospheric refraction originated from a single high precision and high stability oscillator atomic clock The data transmitted in these frequencies contain the inform
26. ment records up to 4 hours of sessions in its internal memory which once downloaded onto a PC enables the analysis of trajectory and speed by way of the MX2 LITE or MX2 software This mode is activated by recording a session see chap 10 2 in this manual Once the session has been memorised it must be transferred to a PC using GATE LITE software The sessions acquired in the DATA LOGGER mode may also be visualised on the View Timing Report menu and may be downloaded as reports in text format onto the PC MD60LOG User Manual rev 05 Copyright O2010 GET by Athena Evolution srl All rights reserved L O TT 6 PREPARATION OF THE DEVICE It is recommended that the entire instruction manual be read carefully before using the unit m Z G U T e Insert the batteries in the battery compartment paying attention to the polarity of each positive pole is on the side without the spring The unit will turn itself on automatically e Close the battery compartment back up again remembering to replace the O ring seal provided and to adequately tighten down the four screws e Position the device on the vehicle keeping the GPS antenna side underneath the writing GET pointed upwards or as far as possible from coverings that may limit the reception of the signal e Make sure that the unit is attached to the vehicle as securely as possible so as to limit the vibrations to which it may be exposed In particular avoid
27. n KPH or MPH Confirmation of the value set comes about by way of the brief pressing of the S SET button STOP DELAY Briefly pressing the S SET button in the field LOG STOP DELAY it is possible to set the time threshold to stop the MD60LOG chronometer The values selectable by way of the ARROW button are from 10 to 30 with increments of 5 Example setting 015 the chronometer stops after the GPS speed has dropped to O for more than 15 seconds Confirmation of the value set comes about by way of the brief pressing of the S SET button FL LENGTH Briefly pressing the S SET button in the field FL LENGTH it is possible to vary the transversal width of the finish lines and the intermediate times of the tracks The range is between 10 m and 500 m with intervals of 10 m between one value and the next settable with the ARROW button Confirmation of the value set comes about by way of the brief pressing of the S SET button ATTENTION the measurement set will be applied permanently to all of the tracks loaded in the MD60LOG see chap 9 2 2 and 10 3 BACKLITE Briefly pressing the S SET button in the field BACKLITE it is possible to activate the backlighting of the MD60LOG display The options available are ON backlighting on to ease reading in the case of low ambient lighting until shut down of the MD60LOG OFF backlighting off AUTO ON backlighting on automatically upon turn on of the MD60LOG ATTENTION Use of the backlight
28. oduct should not be treated as household waste when you wish to dispose of it Instead it should be handed over to an applicable collection point or the recycling of electrical and electronic equipment By ensuring that product is disposed of correctly you will help prevent potential negative consequences to the environment and human health which could otherwise be caused by inappropriate disposal of this product The recycling of materials will help to conserve natural resources For more detailed information about the recycling of this product please contact your local city office household waste disposal service or the retail store where you purchased the product FRANCAIS Directive 2002 95 CE 2002 96 CE et 2003 108 CE du Parlement europ en relative aux d chets d quipements lectriques et lectroniques DEEE Disposition concernant les anciens quipements lectriques et lectroniques applicable dans l Union Europ enne et dans d autres pays europ ens avec des systemes de collecte s par s Ce symbole sur le produit ou sur son emballage indique que ce produit ne sera pas trait comme perte m nag re Au lieu de cela il sera remis au point de collecte d di pour le recyclage de l quipement lectrique et lectronique En s assurant que ce produit est tri et jet correctement vous contribuerez a emp cher de potentielles cons quences n gatives pour l environnement et la sant humaine qui pourraient autrement tre
29. on the unit will load the track and return to visualise the CHRONO page ALBACETE DELETE TRACK lt lt EXIT ALCARAZ ALCARAZ ASSEN ASSEN BINETTO BINETTO CURRENT TRACK e CREATE NEW enables one to go on to create a customised track to be entered into the unit s track library Pressing the S SET button briefly when the item is highlighted by the cursor access to the create tracks function will be given see chap 11 of this manual e DELETE TRACK enables one to delete a track to be entered in the unit s track library Briefly pressing the S SET button when the item is highlighted by the cursor access to the list of tracks will be given by way of the use of the ARROW button to scroll the items and the S button for the selection it is possible to remove the unwanted track from the unit s memory e lt lt EXIT enables the return to the CHRONO page of the unit without making any changes to the track offered in the start menu of the unit The selection of this function comes about briefly pressing the S SET button when the item is highlighted by the cursor LOAD FROM LIBRARY CURRENT TRACK CREATE NEW CREATE NEW DELETE TRACK DELETE TRACK lt lt EXIT MD60LOG User Manual rev 05 Copyright 2010 GET by Athena Evolution srl All rights reserved 10 Access to the menus and the functions of the MD60LOG is possible pressing the S SET button briefly when the unit is on the CHRONO page L e
30. points that could interfere with other components of the track In figure A a proper positioning in figure B a faulty positioning of finish lines on a closed track It is suggested that the finish lines be set at a speed greater than 30 km h 11 5 UPDATING THE TRACK LIBRARY The unit s track library may be updated by way of the GATE LITE software Consult the manual provided in the CD included with the kit to find out the updating methods MD60LOG User Manual rev 05 Copyright 2010 GET by Athena Evolution srl All rights reserved The firmware of the MD60LOG is updated by way of a connection to a personal computer by way of a USB To carry out the updating proceed as follows L O TT e Turn on the instrument and connect to a PC by way of the USB cable e Start up the firmware updating clicking the left mouse button on the self starting file contained in the fw BA fwupdateZ6 exe e Press the UPDATE button and stand by until the end of the updating procedure please attempt that the MD60LOG restart and show SYNC on the display WARNING DON T DISCONNECT USB CABLE UNTIL DEVICE IS RESETTED Firmware update utility This utility will update your MHOGO to the 2 00 version released by AE on 16 2 2010 WARNING iF a connection error or a power failure happens during the firmware update this could lead to a board malfunction Care must be taken in order to avoid these events If any of these e
31. pressing of the S SET button e LANGUAGE Briefly pressing the S SET button in the field LANGUAGE it is possible to set the language for the unit The values selectable by way of the ARROW button are ENGLISH The language of the unit is set to English FRANCAIS The language of the unit is set to French Confirmation of the value set comes about by way of the brief pressing of the S SET button e REF BEST TIME Briefly pressing the S SET button in the field REF BEST TIME it is possible to set how MD60LOG store s the reference best time in its internal memory The values selectable by way of the ARROW button are ALL reference time will be hold in memory until the user change the track on the MD60LOG LAST reference time will be hold in memory until chrono running e lt lt EXIT enables one to return to the CHRONO page on the unit The selection of this function comes about briefly pressing the S SET button when the item is highlighted by the cursor The default settings of MD60 LOG are po TIMEZONE O y PWROFFMIN OO MD60LOG User Manual rev 05 Copyright 2010 GET by Athena Evolution srl All rights reserved m Z G U T 11 CREATION OF A CUSTOM TRACK 11 1 CREATION OF A CUSTOM TRACK IN LOOP MODALITY If you want create a custom track in LOOP modality suitable for closed circuits like car bike speed way or motocross please verify that the TRACK MODE option in OPTIONS men is set as LOOP A
32. provoqu es par la manutention de rebut inad quate de ce produit La r utilisation des mat riaux aidera a conserver les ressources naturelles Pour des informations plus d taill sur la r utilisation de ce produit vous pouvez contacter votre mairie la soci t de collecte et tri des rebuts m nagers ou le magasin o vous avez achet le produit DEUTSCH Richtlinie 2002 95 EG 2002 96 EG 2003 108 EG des Europ ischen Parlaments ber Elektro und Elektronik Altger te Gemeinsame Erkl rung Entsorgung von alten Elektro und Elektronikgeraten g ltig in dar Europ ischen Union und anderen europ ischen L ndern mit separatem Sammelsystem Dieses Symbol auf dem Produkt oder auf der Verpackung bedeutet dass dieses Produkt nicht wie Hausmull behandelt werden darf Stattdessen soll dieses Produkt zu dem geeigneten Entsorgungspunkt zum Recyceln von Elektro und Elektronikgeraten gebracht werden Wird das Produkt korrekt entsorgt helfen Sie mit negativen Umwelteinflussen und Gesundheitssch den vorzubeugen die durch unsachgem Be Entsorgung verursacht werden k nnten Das Recycling von Material wird unsere Naturressourcen erhalten F r n here Informationen ber das Recyceln dieses Produktes kontaktieren Sie bitte Ihr lokales B rgerb ro Ihren Hausm ll Abholservice oder das Gesch ft in dem Sie dieses Produkt gekauft haben ESPA OL Directiva 2002 95 CE 2002 96 CE y 2003 108 CE del Parlamento Europeo sobre residuos de aparatos el
33. re available to exit from the session report selectable by briefly pressing the S button e RETURN TO SESSION the unit returns to the VIEW TIMING REPORT menu e RETURN TO CHRONO the unit returns to the CHRONO page e lt lt EXIT enables the return to the CHRONO page of the unit MD60LOG User Manual rev 05 Copyright 2010 GET by Athena Evolution srl All rights reserved m Z G U T 10 2 DATA LOGGING FUNCTION The DATA LOGGING function enables the user to record a session in the memory of the MD60LOG This function makes a series of data available from the GPS that enable an analysis of the trajectory the speed and the times of the lap with the MX2 LITE and MX2 software providing the user the possibility of understanding how to improve his or her driving performance The MD60LOG memory is capable of containing up to 4 hours of recording It is recommended that you regularly download the data using the specific software before the memory of your MD60LOG is used up entirely visualisation of the message MEMFULL on the display CURRENT TRACK LAP KPH i TRACK j TRACK OPTIONS OPTIONS ONE lt lt EXIT lt lt EXIT Pressing the S SET button briefly when the instrument is in the CHRONO screen the main menu page is accessed e Scroll the main menu items with the ARROW button until the DATA LOGGING item is highlighted e Press the S SET button to activate the session recording mode the instrum
34. re trattato come rifiuto domestico bens raccolto separatamente ed essere consegnato ad un centro di raccolta autorizzato per il riciclo dei rifiuti elettrici ed elettronici oppure reso al rivenditore nel momento dell acquisto di un nuovo prodotto di tipo equivalente in ragione di uno a uno Provvedendo a che il prodotto venga smaltito in modo ambientalmente compatibile si evita un potenziale impatto negativo sull ambiente e per la salute umana favorendo il reimpiego e o riciclo dei materiali di cui composta l apparecchiatura Lo smaltimento abusivo del prodotto da parte dell utente comporta l applicazione delle sanzioni amministrative previste dalla normativa vigente Per adempiere correttamente alla normativa i produttori partecipano a sistemi collettivi che hanno il compito di organizzare e gestire sistemi di raccolta dei RAEE provenienti dai nuclei domestici Per maggiori informazioni contattare l ufficio preposto nella Vostra citt il servizio per lo smaltimento dei rifiuti domestici o il negozio in cui avete acquistato il prodotto ENGLISH Directive 2002 95 EC 2002 96 EC and 2003 108 CE of the European Parliament on waste electrical and electronic equipment WEEE Disposal of old Electrical amp Electronic Equipment applicable throughout the European Union and other European countries with separate collection programs The symbol of crossed out wheeled bin found on the product or on its packaging indicates that this pr
35. rriving at the last intermediate line available LINE4 Once the finish line position LINE5 has been defined by pressing the S SET button the unit will then return to the time measurements page Make sure that the chrono start running by passing the speed threshold defined on START SPEED option this condition it s necessary to allow the saving custom track procedure In these conditions it is possible to start a test session or to save the track just created in the unit s archive see chap 11 3 MD60LOG User Manual rev 05 Copyright 2010 GET by Athena Evolution srl All rights reserved NOTE during the creation of the track it is not necessary to define all of the intermediate positions If just the FINISH LINE is needed it is enough to press the S SET button when the display visualises the message LINE 1 in this condition upon the next passage over the finish line the instrument will begin to read the lap times If only 2 split points and a finish line are needed user can press the S button when the display show LINE3 u CURRENT TRACK LAP KPH CURRENT TRACK LAP KPH L O TT LOAD FROM LIBRARY REATE NE E DELETE TRACK lt lt EXIT E Y PR e e LINE 1 SPLIT1 He A E e W
36. the finish line to the sector just passed RELATIVE upon passing the sectors the time will be displayed counting from the previous sector To confirm the parameter set again briefly press the S SET button e KEEP TIME Briefly pressing the S SET button on the option KEEP TIME you can choose the display duration for the time just recorded The values selectable by way of the ARROW button are 000 no display of the time recorded 005 010 015 020 025 and 030 Example setting 005 upon passing the finish line the time just obtained will be visible for five seconds The setting is also the same for the intermediate times To confirm the parameter set again briefly press the S SET button e TIMEZONE Briefly pressing the S SET button in the field TIMEZONE it is possible to adjust the hour displayed by the MD60LOG the GPS signal actually provides the time at the 0 meridian Greenwich which therefore must be adjusted to the time zone in which one is The values selectable by way of the ARROW button are from 12 to 12 Example if we are in Italy during a month with daylight savings time set the value to 2 Confirmation of the value set comes about by way of the brief pressing of the S SET button e RESET UNIT Briefly pressing the S SET button in the field RESET UNIT the unit will be brought back to its factory default values During this operation the sessions present in the memory will also be MD60LOG User Manual re
37. ual NOTE stand by until the message No SAT fisappears before starting up the unit in CHRONO or DATA LOGGER mode 9 2 2 Turnonof the unit and selection of a track Under normal use of the unit each time that it is turned on with the TRACK SEARCH option set on MAN see chap 10 4 of this manual the display will visualise the following screen SELECTED TRACK PROPOSED TRACK MD60LOG User Manual rev 05 Copyright 2010 GET by Athena Evolution srl All rights reserved m Z G U T In this condition it is necessary to set the track or create a new one if the track proposed by the instrument does not correspond to the track desired push the ARROW button briefly the cursor on the display will shift to the NO item then push the S SET button to access the TRACK SELECTION SELECTED TRACK SELECTED TRACK ADRIA DELETE TRACK lt lt EXIT To scroll the selections on the TRACK SELECTION submenu briefly press the ARROW button once positioned over the option desired press the S SET button briefly to confirm The items available in this menu are e LOAD FROM LIBRARY enables the selection of one of the tracks present in the unit s library Pressing the S SET button briefly when the item is highlighted by the cursor the screen with the tracks present in the library of the MD60LOG will be visualised Scroll the items by pressing the ARROW button and select the track desired pressing briefly the S SET butt
38. v 05 Copyright 2010 GET by Athena Evolution srl All rights reserved m Z G U I deleted The RESET UNIT command will cause the MD60LOG to restart and the user must then reset the system language see chap 9 1 in this manual SPEED Briefly pressing the S SET button in the field SPEED it is possible to select the units of measure for the speed The values selectable by way of tte ARROW button are KPH kilometres per hour MPH miles per hour Confirmation of the value set comes about by way of the brief pressing of the S SET button TRACK MODE Briefly pressing the S SET button in the field TRACK MODE it is possible to set the starting strategy for the MD60LOG chronometer The options selectable by way of the ARROW button are LOOP used in closed circuits and in races with a running start in which the starting line and the finish line coincide LINEAR Used in open tracks such as acceleration races or climbs in which the starting line and the finish line are at two very distant positions To confirm the parameter set again briefly press the S SET button START SPEED Briefly pressing the S SET button in the field START SPEED it is possible to set the GPS speed threshold for the MD60LOG chronometer start The values selectable by way of the ARROW button are from 10 to 150 with increments of 10 Example setting 020 the chronometer will start its count after passing the speed value of 20 whether this is i
39. vent happens DON T POWER OFF THE UNIT and retry until you get a success e Disconnect the USB cable AN ATTENTION USE CHARGED BATTERIES DURING THE FIRMWARE UPDATING NON COMPLIANCE WITH FIRMWARE UPDATE MAY LOCK THE DEVICE MD60LOG User Manual rev 05 Copyright 2010 GET by Athena Evolution srl All rights reserved 13 OPTIONAL Your MD60LOG may be equipped with certain options created specifically by GET to increase its reliability its potential and its service life m Z G U T 13 1 HANDLEBAR SUPPORT KIT Manufactured specifically to increase the reliability and the service life of your MD60LOG also in the most arduous conditions of use the handlebar support kit without stalk FAT BAR with stalk STANDARD BAR and the suction mount support have been designed to permit rapid installation No brackets or screws very simple installation procedure to mount your MD60LOG on the vehicle HANDLEBAR SUPPORT WITHOUT HANDLEBAR SUPPORT WITH STALK STALK FAT BAR STANDARD BAR SUCTION MOUNT SUPPORT MD60LOG User Manual rev 05 Copyright 2010 GET by Athena Evolution srl All rights reserved 14 TECHNICAL SPECIFICATIONS HARDWARE L O TT Internal power supply with two AA alkaline or rechargeable Ni Mh or Ni Cd batteries with protection against overload and incorrect installation of the batteries Maximum autonomy with the system turned on 6 hours with Sony Stamina Plus alka
40. y 5 Hz Current consumption 30 mA 5Hz Sensitivity 158 dBm Normal lock on time with initialised module warm start 33 s Normal lock on time with non initialised module cold start 34 s Normal lock on time with initialised module hot start 1 s Maximum admissible speed 515 m s Maximum CEP 1 8 m Operational temperature from 30 C to 85 C 1 Under the conditions of GPS satellite locked in backlight off led alarms off Measured in conditions of good visibility and with an indicated power signal of 125 dBm MD60LOG User Manual rev 05 Copyright O2010 GET by Athena Evolution srl All rights reserved mm Z G U I MD60LOG User Manual rev 05 Copyright 2010 GET by Athena Evolution srl All rights reserved NOTE NOTES I 9 l O Z Lui MD60LOG User Manual rev 05 Copyright 2010 GET by Athena Evolution srl All rights reserved NOTE NOTES m Z G U I MD60LOG User Manual rev 05 Copyright 2010 GET by Athena Evolution srl All rights reserved eli ITALIANO Direttive 2002 95 CE 2002 96 CE e 2003 108 CE del Parlamento Europeo relative ai rifiuti di Apparecchiature Elettriche ed Elettroniche Smaltimento dei rifiuti elettrici ed elettronici applicabile nell Unione Europea e negli altri paesi europei con servizio di raccolta differenziata Il simbolo del cassonetto barrato presente sul prodotto o sulla sua confezione indica che il prodotto non deve esse
Download Pdf Manuals
Related Search
Related Contents
外線電 温度計 DT-8836 取扱説明書 Silicone Fenêtres et Vitres Recouvrable Hard Disk ToolKit User`s Guide TO Panel MCC Graphic User Interface TO Hand Paddle ADT-HCA1003 McIntosh MT10 audio turntable Partition Manager™ Personal Frame Rails and Crossmembers - VN,VHD SPY-Wシリーズ紹介PDF LeapFrog LeapPad 1 Explorer Parent Guide & Instructions Copyright © All rights reserved.