1. Connect the serial USB cable to the UPS unit and open serial port on the back of the computer You must use the cable that came with the unit The serial USB cable connec Try another serial USB port of your computer ted to the wrong port The unit is not providing battery power The serial USB cable is not connected LestarPowerX3 software in inactive Shutdown your computer aon turn the UPS off Wait 10 sec and turn the UPS back on This should reset the unit The serial cable is not the You must use the cable included with the cable that was provided with unit for the software the unit 11 PACKAGE CONTENT Data zgtoszenia Application date fata 3aaBkn Kreipimosi data Opis naprawy Repair description Onucanne pa6oT no pemourty Remonto apra ymas Data wykonania Execution date Data BbinonHenna Atlikimo data Podpis i piecz serwisu Signature and stamp of service Nognnce n neyaTb cepBucal Serviso antspaudas ir para as The use of WEEE Symbol indicates that this product may not be treated as household waste By ensuring this product is disposed of correctly you will help protect the environment For more detailed information about recycling of this product please contact your local authority your household waste disposal service provider or the shop where you purchased the product Waste Electrical and Electronic Equipment WEEE Symbol A NET WEIGHT OF PRODUCT written
2. SERVICING INSTRUCTIONS USER S MANUAL Uninterruptable power supply unit LESTAR of TS series Sine Wave Technology TS 1100 TS 1500 C Prior to switching on the uninterruptable power supply unit please read carefully these instructions and warranty conditions CONTENTS Use of the uninterruptable power supply unit Safety instructions Exchange of fuse Installation connection and installing remarks Description of operation Feeding strips Properties and functions Design of the uninterruptable power supply unit Technical data Malfunctions and remedies Equipment Warranty Warranty card CoS UT A NS O wnrso 1 USE OF THE UNINTERRUPTABLE POWER SUPPLY UNIT UPS Uninterruptable power supply unit is designed for work with the equipment of infor mation systems such as computers networks servers modems as well as other electronic equipment such as revenue cash registers and telephone exchanges Use of the uninterrupt able power supply unit with electric appliances such as refrigerators electric water kettles mechanical household appliances AGD and other electric motors is unallowable LESTAR will not bear any responsibility for damages caused as a result of improper connection of the afore mentioned equipment 2 SAFETY INSTRUCTIONS ATTENTION 1 UPS is equipment designed for high voltage operation Inside the unit there are live parts dangerous for human life 2 Please don t open yourself t
3. equipment mainly for computer systems to be used for professional purposes and in households The application of a uninterruptable power supply unit eliminates 230V line interference over voltages current pulses voltage decays and ensures stable and dependable operation of computer systems During normal mode of operation when supplied from supply mains green diode is illumi nated The uninterruptable power supply unit will filter the existing voltage thus eliminating line interference and in the case of a drop or growth of voltage the AVR system automatic voltage regulation is being stabilized on the 230 V level In the case of mains voltage decay the uninterruptable power supply unit during a fraction of second 6 ms is being switched over to the work from a accumulator This is being sig naled by a slow flickering of the green diode and a sound signal synchronized with it every approx 3 sec Quick flickering of diode and the same sound signal every approx 1 sec means that the accumulator has been almost fully discharges and that after a moment the uninterruptable power supply unit can be disconnected This is being signaled by extinguish ing of the yellow diode Emergency supply time is dependent upon the degree of charging of the accumulator and the load connected to the uninterruptable power supply unit and amounts 6 to 16 min The uninterruptable power supply unit is provided with a function owing to which it may be switch
4. next to the bar code on the box or in technical data 12 WARRANTY PLEASE CONTACT YOUR REGIONAL DEALER FOR DETAILS with a power generating set V SOFTWARE FOR COMMUNICATION PORT 12 follow the on screen instructions 1 LESTAR uninterruptable power supply unit x1 9 If you don t anticipate the use of UPS for a longer period of time please charge the ac The uninterruptable power supply unit is provided with a communication port RS232 13 When the installation is completed remove the installation disk 2 Cable IEC 320 for the unit being supplied x2 cumulator for minimum 12 hours every 3 months with USB adapter After having been connected to the computer it together with the FOR WINDOWS 2000 3 Spare fuse in supply socket WTA T 8A x1 10 Full discharging of accumulator can lead to a considerable shortening of its service life software renders possible control of operation of emergency uninterruptable power 1 Click on start point to settings and click Control Panel 4 Servicing instructions warranty card x1 After discharging it should be charged again as soon as possible If the device has been supply unit 2 Double click on power options 5 Cable RS 232 software LestarPowerx3 x1 fully discharged for a period of time longer than 3 days it could be irreversibly dam 3 Onthe UPS Tab click select 6 Phone cable RJ 11 or RJ 45 x1 aged 4 In the UPS Selection Dialog Box under Manufactures click None IN 25 EN 7 Cable USB x1 SERVICING INSTRU
5. power will take place after removal of the clamp from the accumulator Such operation may be performed by an authorized serviceman only 12 In order to exchange the battery please contact with the service station indicated by LESTAR 13 This device is not a lighting protector Should a house or antenna be directly struck by a lighting ups might not protect your equipment 14 The uninterruptable power supply unit should be connected to a socket whose phase wire has been protected by a fuse of rated value not greater than 16A This is in conform ity with the regulations IEC 950 EN 69950 2000 as far as user s safety is concerned To this aim oblige the installer of the device to check the electric system of the building room where the uninterruptable power supply unit will operate 3 EXCHANGE OF FUSE In the case of connection of a unit whose power consumption exceeds considerably the rated value or in the case of a short circuit in the mains socket the fuse can be blown out The fuse as well as the spare fuse are located in a holder in the rear panel of the device In order to exchange the fuse switch off the UPS by means of the power switch and then pull out the supply cable from the socket pull out the fuse holder and exchange the fuse delay fuse WTA T 10A 4 INSTALLATION CONNECTION AND INSTALLING REMARKS 1 Unpack UPS in order to check whether the product has not been damaged Should any damages be detected contact w
6. service and repair of the strip is considerably lower than of each UPS separately We do recommend the use of LESTAR supply strips and comparison of the data and technical parameters z iiia SURGE EMI RFI NOISE PROTECTOR LESTAR UPS LESTAR COMPUTER 7 PROPERTIES AND FUNCTIONS vV TRUE SINE WAVE ON OUTPUT In back up operation status UPS output voltage is perfectly sinusoidal The course pattern is not changed under the influence of UPS load increase or decrease vV FULL AVR FUNCTION Operation with AVR function consists in regulation of output voltage on a level of 230V 410 In spite of fluctuations of the input voltage within the limits from 170V up to 280 V the output voltage is constant Voltage regulation is effected without drawing energy from an accumulator V LINEAR INTERACTIVE SUPPLY OF UPS OUTPUT AVR function is combined with switching over to operation with supply from accumula tor when the threshold of operation of AVR system has been exceeded Within the range of voltage from 170 V up to 280 V regulation of output voltage takes place by means of AVR function Should voltage drop below 170V or raise above 280V then the uninterruptable power supply unit will be switched over to operation with supply from an accumulator V COLD START The uninterruptable power supply unit can be started when not supplied from the sup ply mains This function is possible only for a standard set consisting from a computer and 15
7. CTIONS OF EMERGENCY UNINTERRUPTABLE POWER SUPPLY UNITS LESTAR TS 1000 TS 1500 ENGLISH SERVICING INSTRUCTIONS OF EMERGENCY UNINTERRUPTABLE POWER SUPPLY UNITS LESTAR TS 1000 TS 1500 ENGLISH SERVICING INSTRUCTIONS OF EMERGENCY UNINTERRUPTABLE POWER SUPPLY UNITS LESTAR TS 1000 TS 1500 ENGLISH
8. See the figure 3 Plug the UPS into an AC outlet turn the UPS on and start your computer 4 Follow the instructions on the User s Manual to complete the installation FOR WINDOWS 95 98 ME 1 Turn the UPS off and unplug it 2 Connect the serial interface cable to serial port on the UPS and an open serial port on the back of the computer Note You must use the serial cable that was supplied with the unit 3 Plug the UPS into an AC outlet turn the UPS on and then start your computer 4 Windows will find new hardware 5 Insert the LestarPowerX3 installation disk into drive then follow the on screen instructions 6 When the installation is completed remove the installation disk FOR WINDOWS NT Click on start point to settings and then click Control Panel Double click on the UPS into an AC outlet turn the UPS on and then start your computer Remove the check mark from the box label UPS is installed on and click OK Acknowledge the message that the UPS is in an unknown state Exit to the desktop then shutdown your computer Turn the UPS into AC outlet turn the UPS on and then start your computer Connect UPS with computer Note You must use the serial cable that was supplied with the unit 8 Plug the UPS into an AC outlet turn the UPS on and then start your computer 9 Click start point to settings and click control panel 10 Double click on Add Remove Programs 11 Insert the LestarPowerX3 installation disk into
9. drive and click install AO Oe WN POWER SUPPLY UNITS LESTAR TS 1000 TS 1500 ENGLISH Exit to the desktop and shutdown the computer Turn the UPS off and unplug it Connect UPS with computer Plug the UPS into AC outlet turn the UPS on and then start your computer 9 Windows will find new hardware 10 Insert the software installation disk into the drive and follow the on screen instructions 11 When the installation is completed remove the installation disk FOR WINDOWS XP HOME AND PROFESSIONAL oN AW 1 Click on start and then click on the UPS tab 2 Double click on Power Options then click on the UPS tab 3 Set the manufacturer to None 4 Inthe UPS off and unplug it 5 Exit to the desktop and shutdown your computer 6 Turn the UPS off and unplug it 7 Connect UPS with computer 8 Plug the UPS into AC outlet turn the UPS on and then start your computer 9 Windows will find new hardware 10 Insert the software installation disk into the drive and follow the on screen instructions 11 When the installation is completed remove the installation disk When the installation is completed LestarPowerX3 software will appear on your screen for a few seconds and the minimize It will apper as a blue and white bettery icon located in the sytem tray near the clock 9 TECHNICAL DATA Model TS 1000 TS 1500 Power 1100VA 700W 1500VA 1000W Input Rated input voltage 230V Rated input current 8A Swi
10. e power expressed in Watts connected to the both sockets may not exceed 700W TS 1000 and 1000W TS 1500 V SOFTWARE FOR COMMUNICATION PORT The uninterruptable power supply unit is provided with a communication port RS232 with USB adapter After having been connected to the computer it together with the software renders possible control of operation of emergency uninterruptable power supply unit SERVICING INSTRUCTIONS OF EMERGENCY UNINTERRUPTABLE POWER SUPPLY UNITS LESTAR TS 1000 TS 1500 ENGLISH SERVICING INSTRUCTIONS OF EMERGENCY UNINTERRUPTABLE 8 DESIGN OF THE UNINTERRUPTABLE POWER SUPPLY UNIT ALARMS AND SIGNALING LP POWER PRACA Z BOOST BUCK BEZ ALARM STAN PRACY ZASILACZA ON BATERII PIEC ZNIK 1 On off off off Normal off Normal Max boost 14 of input voltage for 2 On Off On Off Normal Off output regulation while input voltage is from 6 to 17 under nominal Max boost 30 of input voltage for 3 On Off On Off Normal Off output regulation while input voltage is from 18 to 26 over nominal Max buck 12 of input voltage for 4 On off off On Normal off output regulation while input voltage is from 7 to 22 over nominal Two Utility failure The UPS is providing 5 Off On Off Off Normal Beeps battery power to the Battery Power Supplied outlets Utility failure The UPS is providing Rapid battery power The rapid beeps beeps indicate the battery will run out of charge with
11. ed on without an external supply so called cold start This has been described in the chapter devoted to the properties and functions of the uninter ruptable power supply unit 6 FEEDING STRIPS Frequently expressed opinions that the uninterruptable power supply units perform also the function of anti interference strips is erroneous Extended LESTAR strips of POWER MUL TIPROTECTOR POWER MASTER HIGH series have incomparably greater possibilities of at tenuation and adsorption of energy than UPS units available on the market As a result their application ensures far greater efficiency and better protection of your valuable equipment In order to better understand the level of protection compare the data given below with the data of the uninterruptable power supply units Absorption of pulse energy Max current Attenuation PowerSuperprotector 909 Joules 30000 A 70 dB PowerMultiprotector 1818 Joules 30 000A 70 db PowerMasterHigh 5 4 613 Joules 22000 A 60 dB Most uninterruptable power supply units have filtering systems and varistor attenuators of very low values of the adsorbed energy Some of them don t have them at all and so the exist ing level of protection is questionable Hvence in the case of a strong impact and damaged varistor attenuator also the application of an anti interference strip before the UPS being connected also brings about a considerable financial advantage because the possible cost of
12. he casing don t make repairs etc since this brings about hazard of electric shock If you have some questions please come into contact with our company or the salesman 3 The device is not recommended for protection of life saving equipment 4 Please don t spill liquids on the UPS casing or inside it 5 The uninterruptable power supply unit should be stored in dry rooms Avoid location of UPS in the neighborhood of environment of considerable humidity or in the vicinity of liquids such as chemical water solutions 6 Avoid location of UPS in a place where it will be exposed to the action of sun rays or other heat sources as well as in the places of low temperature Recommended tempera ture range is 15 C 25 C 7 Please don t plug ventilating holes making possible escape of heat from the interior of UPS 8 For connecting UPS please use grounded supply cable connecting plug of UPS should be plugged in to a socket having grounding circuit 9 Under normal working conditions when supplied from supply mains UPS is protected by a fuse against overloading or short circuit 10 Supply socket to which UPS has been connected should be located close to the device and should be easily accessible 11 The uninterruptable power supply unit should have its own source of power internal accumulators UPS output can be under tension even if it has been disconnected from supply mains Full disconnection of UPS from the source of
13. in a few minutes 6 Off On Off Off Normal Overload Occurs in the full time Two surge protection outlets Turn the 7 Off On Off On Off On Off Blown beeps UPS off and unplug at least one piece orrapid of equipment from the UPS Check beeps the fuse and do the replacement if necessary Turn the UPS on Overload Occurs in the battery i power supplied outlets Turn the Mor Leng UPS off and unplug at least one piece 8 Off On Off On Off On Off mal Beep of equipment from the UPS Check Blown the fuse and do the replacement if necessary Turn the UPS on EXTERNAL ELEMENTS TS 1000 TS 1500 1 Power Switch Press the power button to turn the UPS ON or OFF 2 Power On Indicator This LED is illuminated when the utility condition is normal and the UPS outlets are providing clean power free of surges and spikes 3 Using Battery Indicator This illuminates during utility failure indicating that the battery is supplying power to the battery power supplied outlets 4 Boost indicator This LED indicates that the UPS is operating in automatic voltage regu lation mode When the led is illuminated continuously it indicates that input over volt age and that the UPS unit boosts input voltage 5 Buck indicator This LED indicates that the UPS is operating in automatic voltage regula tion mode When the led is illuminated continuously it indicates that input ove
14. inforcement 2 output sockets IEC 320 with surge protection Up to 30 dB from a distance of 1 meter Right of modifications without separate notification reserved by the manufacturer 10 MALFUNCTIONS AND REMEDIES Noise level Problem Supposed reason Solution The UPS does not Batteries are not fully Recharge the battery by leaving th UPS perform expected charged plugged in runtime Battery is slightly worn out Contact Lestar company The UPS will not The on off switch is designed Turn the UPS off Wait 10 sec and then turn turn on to prevent damege by rapi the UPS on dly turing it off and on The unit in not connected to The unit must be connected to a 220 240V an AC outlet 50 60Hz outlet The battery is worn out Contact Lestar company The unit is mechanically broken Outlets do provide Fuse is blown due to power to equipment overload Contact Lestar company Turn the UPS off and unplag at least one piece connected equipment Unplug the power cord of the UPS then remove the fuse compartment beneath the power inlet of the UPS and replace the blown fuse with a spare one Lock the compartment back to the UPS Connetct power cord then turn the UPS on Make sure that your spare fuse meets the spcecification 10A 250V 5 x 10mm Allow the unit to recharge for at least 4 hours Batteries are discharged Unit has been dameged bya Contact Lestar company square or spike
15. ith the salesman 2 Connect the AC supply cable to UPS socket 3 Depress the power switch LED will illuminate which means that UPS is supplied with alternating current 4 Connect the computer supply cable or the supply cable of other peripheral equipment IEC 320 to output sockets of UPS Then switch on the computer and disconnect UPS supply cable in order to check the unit for proper operation Supply cable is to be discon nected by removing the plug with a grounding pin from the mains socket 5 Prior to proceeding to operation of the unit switch on UPS and charge it for 8 hours This will enable to charge the accumulator Should operation of the unit begin before a full charging of the accumulator then the time of emergency operation will be shorter than the full capacity of the accumulator 6 UPS is switched off by depression and hold back of the power switch which is accompa nied by extinguishing of LED 7 Don t use UPS with laser printers electric motors and mechanized appliances because of a high starting current 8 Don t connect the uninterruptable power supply unit to an electric system cooperating 11 Accumulator will re gain its full operating capacity after about 1 month of mains operation 12 Permissible value of current leakage to the earth must not exceed 2 5mA 5 DESCRIPTION OF OPERATION Emergency uninterruptable power supply units of OfficePower AVR series are up to date source of power for various electronic
16. monitor and is activated by switching on the power switch The uninterruptable power supply unit will then operate in the emergency mode of operation and will take energy from the accumulator vV TELEPHONE FILTER RJ45 UPS offers the possibility of connection of a modem or telephone Telephone line is pro tected against over voltage and interference which can occur in the telephone network V PROTECTION OF ACCUMULATOR FULL DISCHARGING Microprocessor automatic system for testing and control of operation of the emergen cy uninterruptable power supply unit protects the uninterruptable power supply unit against full discharging Should condition close to full discharging be detected then the uninterruptable power supply unit will be completely disconnected V SOUND SIGNAL OF OVERLOADING OR FULL DISCHARGING OF ACCUMULATOR Full discharging of accumulator and switching off of the uninterruptable power supply unit in a short time is signaled by a quick flickering of the green diode and a single sound signal lasting 1 second VY AUTOMATIC SWITCHING OFF IN THE CASE OF A SHORT CIRCUIT OR OVERLOADING The uninterruptable power supply unit is being automatically switched off in the case of overloading or short circuit This is being signaled by a long acoustic signal vV OUTPUT SOCKETS In order to be connected to a computer the uninterruptable power supply unit has been provided with 6 output sockets 4 battery backup outlets and 2 surge protectoions Activ
17. r voltage and that the UPS unit bucks the voltage 6 Battery Backup and surge protector outlets The UPS provides battery powered and surge protected outlets for connected equipment to insure temporary uninterrupted operating during a power failure and against surges and spikes 7 Surge protection outlets The UPS provides surge protected only outlet for connected equipments against surges and spikes 8 USB and Serial port to PC This port allows connection and communication form the DB 9 serial or USB port on the computer to the UPS unit The UPS communicates its status to the LestarPowerX3 software This is also compatible with the UPS service provided by Windows 98 Windows ME Windows NT Windows 2000 Windows XP Windows Server 2003 and Mac OS 10X 9 Ethernet RJ45 Network Protection Ports These ports are the protection for your com puter network cable 10 USB port option 11 Name plate COMMUNICATION WITH COMPUTER AND SOFTWARE INSTALLATION Lestar UPS can provide surge suppression and battery backup without the software How ever if you need to schedule for UPS Auto shutdown then it is necessary to install the soft ware LestarPowerXx3 COMMUNICATION 1 Turn off your UPS 2 Connect the serial interface cable to your UPS and the open serial port on the rear panel of the computer If you would like to use USB interface please connect the USB adapter with the Serial Cable then connect the USB to your computer
18. tching over threshold 170V 280V supply mains UPS Input frequency 50 Hz 60Hz Output oe voltage range 230V 10 Output frequency 50 Hz 1 of accumulator Course form Approximate sinusoid 230Vac 5 Switching over time Accumulators Type Back up time Pmax P 0 5max Charging time Kind of accumulator Protection of accumu lt 6ms Sealed lead acid accumulator service less 6 14 min 6 12 min 8 hours to 90 full capacity 12V 9Ah x 2 12V 10Ah x 2 Protections F 2 B Auto test and full accumulator charging protection lator Auto test Auto test after every switching on Indicators Signaling diode Power On Using Battery Boost Buck Acustic signal On Battery Low Battery Overload Electric Protection against 440 Jouli protection current surge Protection against 106 when load is 94 106 buzzer sounds When load is overload over 106 continously UPS will be turned off automatically within 90 seconds Bezbiecznik na wyj ciu 10A Voltage filtration Interference eliminator RFI EMI Protection Modem Sup RJ 45 ply mains Communi Interface RS232 and or USB cation with Software LestarPowerX3 computer Windows 98 ME 2000 NT XP Mac OS 10 X Others Dimensions mm length x width x 30 9cm x 14 1 cm x 18 4cm height Weight 14 6kg 15 5kg Working conditions Temp 0 35 C up to 95 humidity Storage does not cause condensation15 45 C Sockets 4 output sockets IEC 320 damaged re