Home
Block - Sistem Air
Contents
1. Right entry Left entry Right entry exit Left entry exit Left entry Right entry frontal discharge frontal discharge right exit left exit 38 www sistemairit rif 01 2008 ENG Built in central unit DOMESTIC central vacuum Systems SPARE PARTS TABLE ART 8200 0 8200 1 MODEL Wolly 150 Wolly 300 ARTICLE Filter cartridge Wolly Quantity 1 piece 1613 14 Motor Quantity 1 piece 1613 15 Bags Quantity 10 pieces Electronic board A Wolly SESEL SOFT START SYSTEM N Quantity 1 piece 1612 10 Motor brushes San Quantity 2 pieces EC 1611 10 ACCESSORIES TABLE ART 8200 0 8200 1 Wolly 150 Wolly 300 ARTICLE Remote control wall panel Quantity 1 piece 39 rif 01 2008 ENG www sistemair it DOMESTIC JOLLY SYSTEM ease of installation ror pre built houses www sistemair it SMALL APARTMENTS HOBBY ROOMS DOMESTIC JOLLY SYSTEM Up to 60 m 1 Operator Oe Suction unit JOLLY JOLLY Contact JOLLY SYSTEM Jolly is an innovation in the central vacuum world It is a single vacuum motor in a plastic case which can be mounted either in or on a perimeter wall of the building or even more in any wall Its ch
2. ny ee E cR ise e 350 E le NE m 300 I P Pa 300 3 1 azi 300 a i 250 4 250 1 2 1 coe esl Es 200 4 200 07054 Wu ER CM 150 2 r3 r1 rT42 r TA 150 150 34 D ANN T i 100 eden A eg 1 1 1 jme miel dO DM 1 I og 1 1 50 50 i3 anan i DE s 0 m3 h 0 m3 h 0 m3 h S lt amp 100 200 300 400 500 Airflow 100 200 300 400 500 Airflow PP SG S S 2 YO Air flow rif 01 2008 ENG www sistemair it Art 060006 mbar Vacuum Art 060005QE rif 01 2008 ENG Dust Separators Blowing Power Units Range Peripherals of central units m INDUSTRIAL PERFORMANCE GRAPHS They reflect the flow vacuum curves for electric motors fitted with electronic speed converter Vacuum mbar lt lt e e E ko NE EE MES A a e A J n
3. LI N E S SISTEM AIR 3301 4 i re i S 12 Vdc R1 R2 R3 R4 90909262 Clamps for the connection of inlet valves N B The clamps should not necessarily all be used 85 rif 01 2008 ENG www sistemair it um Dust Separators Blowing Power Units Range Peripherals of central units INDUSTRIAL EXAMPLES OF DIVIDER INSTALLATION The resistive divider is essential when you want to modulate the speed of a mo tor body or control the turning on and off of more than one motor body Each divider can hold up to four inlet valves that can be linked up to each other with no maximum limit An installation example of the micro line with resistive divi ders is then schematically represented C ES 5 EMEN gi 2 N NENNEN 2 E d 4 o 5 9 5 A ME sl rcc H A ALELA ALA Eu gt m 2 UO L o S Ex i t 2 5 i Oe Ei t O i d 5 s HaH H HSHSHSHSHSESHESHSHESHESHESHESHSHESES _ monn S Di 5 lt H on
4. BL d e a A ee Li EOC L EL L LE ELL e E X O 1 E E S Li o an N i 6 3 o 9 EN CN lt 1 LA vi 3 H pu a 3 wa gt gt 86 rif 01 2008 ENG www sistemair it Dust Separators Blowing Power Units Range Peripherals of central units INDUSTRIAL central vacuum Systems GUIDE TO THE CORRECT SELECTION OF INDUSTRIAL CENTRAL UNITS As a demonstration of the complete possibility of modulating these systems diffe rent kinds of installations are proposed on a par with the number of simultaneous operators Following the tables below it is possible to highlight all the codes and quantity required to correctly select a central vacuum unit in the industry Identifying the product can be done on the basis of a number of operators and can be divided into three different options BASIC SOLUTION While running the central unit motor always absorbs with the maximum power and when starting up has no device that limits the peak current absorption IDEAL SOLUTION The central vacuum unit motor starts up with the help of an electronic devi ce that lim
5. Dust bags Quantity 20 pieces 1613 13 Motor body Quantity 2 pieces Motor start up board a Quantity 1 piece Electronic board for computer Quantity 1 piece rif 01 2008 ENG ACCESSORIES TABLE TECNO Star ART 3115 0TS TECNO STAR ARTICLE remote table panel Quantity 1 piece 110002 Air vent silencer Quantity 1 piece Remote control wall panel Quantity 1 piece www sistemair it DOMESTIC SISTEM CUBE a brilliant solution for any space Emm www sistemair lt VERTICAL BUILDING J 30 LA DOMESTIC www sistemair it Central vacuum unit INSTALLATION AREA The Sistem CUBE central vacuum unit is suitable to be installed in domestic environments with the following characteristics Surface to be cleaned up to 120 Piping system with 40 mm diameter pipe and 40 mm diameter inlet connector to the central unit 220 240 V power supply Air exhaust to the outside Suitable for use by one single operator DISTINCTIVE FEATURES OF THE PRODUCT Sistem Cube has all the specifications of a traditional Sistem Air centralised vacuum system that is it requires the positioning of a piping network it sends micro dust outside and requires the use of a simple flexible hose to clean the house However this unit stands out thanks to its incredibly compact
6. 290 a 77 68 N L i e o o e 5 0 e 0 1 S 2 to 50 72 rif 01 2008 ENG Sistem CUBE central vacuum unit DOMESTIC central vacuum Systems ARTICLE OF ECmounting PVCPipes MFelbow FF elbow FFF Coupling Ventgrate Conduit Special glue Pipe adapter Sockets plate Pieces m Pieces Pieces derivation Pieces Pieces m Pieces 40 50 Pieces 40 installation kit with rectangular mounting plates ARTICLE OF ECmounting PVCPipes FFelbow FF elbow Coupling Ventgrate Conduit Specialglue Pipe adapter Sockets plate Pieces m Pieces Pieces derivation Pieces Pieces m Pieces 40 50 Pieces 7030 02E 2 15 10 14 1 10 1 25 2 3 7030 03E 3 20 15 21 2 15 1 25 3 4 TABLE OF SPARE PARTS Sistem CUBE ART 8300 0 Sistem CUBE ARTICLE Filtre cartridge 1610 15 Quantity 1 Piece Bags 1614 15 Quantity 10 Pieces Motor Quantity 2 Pieces Motor brushes Electronic board Quantity 1 Piece 35 rif 01 2008 ENG www sistemair it ELIE DOMESTIC Wolly Up to 300 m 1 Operator Ou 36 www sistemair it Built in central unit INSTALLATION AREA The Wolly built in central vacuum unit are suitable to be used in residential area on surfaces up to 300 ma The compact dimensions and the versatility of installation makes of it the ideal solution for all those applications that ta
7. 50 2 air vent 110001 silencer Quantity 1 piece Motor 1623 7 Quantity 1 piece 1623 8 1623 9 1623 10 1623 11 Motor brushes 1611 10 Quantity 1 piece 1611 11 Electronic board 1612 4 for motor Quantity 1 piece Electronic board for computer Quantity 1 piece Dast bags 1614 4 Quantity 10 pcs 148 www sistemairit rif 01 2008 ENG SPARE PARTS central vacuum systems SPARE PARTS FOR DOMESTIC SERIES SISTEM AIR spare parts are individually packed TECNO ACTIVA TECNO EVOLUTION CENTRAL UNIT SPARE PARTS Filter cartridge Quantity 1 piece 50 2 air vent silencer Quantity 1 piece Motor Quantity 1 piece Motor brushes Quantity 2 pieces Electronic board for motor 2 Quantity 1 piece Electronic board for computer Quantity 1 piece Dast bags Quantity 10 pcs rif 01 2008 ENG TECNO Evolution TECNO Activa ART 3107 0 3108 0TE 3109 0 3110 0TE 3112 0TE 3113 0TE 3115 0TE 3107 3108 0TA 3109 0TA 3110 0TA 3112 0TA 3113 0TA 3115 0TA MEDIA MEDIA SA 050 ps x zx MEDIA MEDIA SA 050 SA 200 SA400 5 MODEL ARTICLE 1610 0 1610 5 110001 1613 7 1613 8 1613 9 1613 10 1613 11 1611 3 1611 4 1611 5 1611 6 1611 7 1612 4 www sistemair
8. L PROFESSIONAL Central vacuum unit Series TECNO Block Mini TECNO Block Maxi 58 Linea TECNO Block Maxi without self cleaning Linea TECNO Block Maxi with self cleaning Up to 1200 m2 3 Operators T CC Qu RECOMMENDED INSTALLATION The central units are fitted with a connection for the air vent piping which is essential for sending the micro dust that the filter cartridge cannot contain outside They should be installed in service rooms for example in garages cellars etc that are closed to protect other rooms from noise coming from the central unit and protected from extreme weather conditions dampness and excessive temperature changes You should choose areas at some distance from heat sources such as heaters or central heating IP 20 insulation level At the planning stage it is advisable to identify the best location for the central unit with respect to the system leaving a reasonable amount of space for installation use maintenance and a correct re circulation of air around the central unit In the event of a system on several floors it should be installed on the bottom floor www sistemair it INSTALLATION AREA The Maxi Block central vacuum units in the Tecno Block range are available in different versions for use in residential homes and small businesses It is spe cifically indicated for all the system cases with extended piping that have the following char
9. 5 e LA LA e LA LA LA N N e 100 200 300 400 500 0 450 400 B50 ae 300 250 e 150 100 rif 01 2008 ENG www sistemair it 60 Central vacuum unit Series TECNO Block Mini TECNO Block PROFESSIONAL central vacuum systems SUMMARY TABLE OF AVAILABLE SPEEDS AND KINDS OF SELECTION MODEL ARTICEL Speed can be set Speed can be modulated Speed converter Electronic card for speed manually electronically modulation 3200 0 MB 3200 3 MB 3200 1 MB 3200 2 MB TECNO 3200 4 MB Block Maxi 3200 5 MB 3200 6 MB 3200 7 3200 8 lt lt 2 aye lt lt 8 52 3200 9 Description Number of speeds that can be set e g Bl lll 2 speeds can be set Available Unavailable 1 Can only be used with systems using resistive divider cards art 3301 4 FITTING THE CENTRAL UNIT No particular attachment is needed although you should ascertain that the se lected installation area has the minimum requirements for a correct and saf
10. DOMESTIC JOLLY SYSTEM SPARE PARTS TABLE ACCESSORIES TABLE JOLLY serie JOLLY serie ART 8710 0 8720 0 ART JOLLY MODEL JOLLY GANG ARTICLE ARTICLE Jolly box to be fitted 8500 0 into the wall Quantity 1 piece Bags Quantity 5 Pieces Blind wall box coverQuantity 1 piece Motor protection filter Quantity 5 Pieces Motor body Quantity 5 Pieces Jolly box for outside Quantity 1 piece Jolly contact electronic card Quantity 1 Piece Jolly extension box Quantity 1 piece Jolly set of grates for air discharge Quantity 1 piece TITTT Jolly set of joints e for side discharge e Quantity 1 piece 8600 0 9 metri Jolly cleaning accessories kit Quantity 1 piece 8600 0R 12 metri Grained wood 8900 0 coloured decorative frame Quantity 1 piece Light carbon coloured decorative frame W Quantity 1 piece 8900 1 44 22772 www sistemair it rif 01 2008 ENG JOLLY SYSTEM EXAMPLES OF INSTALLATION INSTALLATION WITH DIRECT DISCHARGE ARTICLE DESCRIPTION Quantity Jolly module Jolly contact module Jolly box wall box Jolly extension box Set of grates for air discharge INSTALLATION WITH SIDE DISCHARGE ARTICLE DESCRIPTION ZALBE Jolly Module Jolly Contact module Jolly
11. DESCRIPTION 2 S mE 1450 13 ROUND MOUNTING PLATE elbow connector Y 50 61 ROUND MOUNTING PLATES 10 ARTICLE 1450 12 118 l www sistemair it DESCRIPTION ROUND MOUNTING PLATE straight connector Packing pieces rif 01 2008 ENG Mounting plates for inlet valves MOUNT PLATES AND INLET VALVES i central vacuum Systems INSTALLATION KIT FOR PLASTERBOARD WITH INLET VALVE The installation kitfor plasterboard allows an easy and quick installation of Sistem Air square inlets in any wall in plasterboard The adapter allows the installation of Sistem Air mounting plates if you prefer not to use the installation kit INSTALLATION KIT FOR PLASTERBOARD ARTICLE DESCRIPTION COLOUR Packing pc 1464 6B White INSTALLATION KIT FOR PLASTERBOARD 2 Black WITH INLET VALVE 1464 6 1464 6G Silver ADAPTER FOR SQUARE MOUNTING PLATE ARTICLE DESCRIPTION Packing pc 1450 18 ADAPTER FOR SQUARE MOUNTING PLATE SCHEMATIC REPRESENTATION 119 rif 01 2008 ENG www sistemair it GEN MOUNT PLATES AND INLET VALVES Extension kits EXTENSION KITS FOR MOUNTING PLATE AND INLET VALVE The mounting plate extension kit represents a real innovation in the sector Than ks to this innovation it is possible to extend the wall box by multiples of a centi metre without size limitations the flat inlayed box ens
12. ve 0 WNSSSSSSSRSSSSSSSSS S AN LR E d AA AAA AAA AD E 4 VS Kann l KS 76 www sistemair it rif 01 2008 ENG Dust Separators Blowing Power Units Range Peripherals of central units INDUSTRIAL central vacuum systems SUMMARY TABLE OF AVAILABLE SPEEDS AND KIND OF SELECTION MODEL ARTICLE Speed can be set Speed can be modulated Speed converter Electronic board for speed manually electronically modulation 060005Q 060006Q 060008Q Industrial motors 060006QE 060008QE Legende M Number of speeds that canbe 2 speeds be set X Available INO 1 Can only be used with systems fitted with resistive dividers parts no 3301 4 2 on request not included parts no 3301 5 PERFORMANCE GRAPHS They reflect the flow vacuum curves for the standard motors with direct start up not fitted with electronic speed converter Frequency used 50 Hz Speed 1 Art 060005Q Art 060006Q Art 060008Q Vacuum Vacuum Vacuum mbar mbar mbar 450 vale 450 pan ene loce ter 400 o 350 mm Peo Sa p o a Iaea E I i
13. 102 Mi ECC 4 ia IT PS epe r 9 D met ra Rp je _ L dT de 17 e e 1 l S d 1 I 1 I I cN po 1 NE NE ME t ipm eee ee e 1 1 EL ot mg 1 1 1 5 G po T T T T T 3e LA LA e LA LA e LA gt cN N e DE lt Fera e ies ie ak I Epa c T JERSEY ISSN es 1 1 N ESBAS lt 1 1 S b 2 ao I LA e SF Speed 1 Speed 2 Speed 3 Speed 4 78 WWVW sSistemaitr it TECHNICAL SPECIFICATIONS The Industrial series of vacuum motors have been designed and built in com pliance with current legislation and EU directives without however neglecting the fundamental elements such as operational ability power and practicality of use Its main technical characteristics can be listed as follows Bearing structure base in epoxy powder painted metal Professional CE motor pump unit insulation cat F Power varies according to the model Vacuum pump with side c
14. Option of placing eitherontherightortheleft Re 4 1 PIPE CUTTER FOR PVC AND SPARE PARTS ARTCLE DESCRIPTION PACKING pcs Pipe cutters up to 0 63 mm Pipe cutters up to 100 mm Spare wheel for pipe cutters rif 01 2008 ENG EQUIPMENT AND SYSTEMS central vacuum systems SCREW CAP FOR TESTING INSTALLATION ARTICLE COLOUR MATERIAL PACKING pcs 5050 5 Black Plastic VACUUM GAUGE FOR SYSTEM TESTING ARTICLE COLOUR MATERIAL PACKING PCS 4001 0 Steel Metal 145 rif 01 2008 ENG www sistemair it EQUIPMENT AND SYSTEMS Sistem TEST 146 j www sistemair it Sistem TEST PRINCIPAL CHARECTERISTICS SISTEM Test improves the work of the specialized installer during the installation of Sistem Air vacuum units Thanks to this transportable unit which is already provided with a vacuum gauge it will be possible to certify the correct installation of the system after the installation of the piping system It is possible to test the tightness of the same and to release a certificate which represent a further guarantee for the client that his system has been realized according to the rules of the trade With Sistem Test you will beprovided with everything necessary to test the system The Sistem Test unit with vacuum gauge for a quick and precise reading of the pressure drop of the system It can be easily moved thanks to its weels A hose to c
15. WALL REMOTE CONTROL PANEL WITH BOX AND PLAQUE ARTICLE COLOUR MATERIAL PACKING pcs White KUNSTSTOFF Supply Wall box Model 503 Vimar IDEA 3 plaque Bianca modules ELECTRIC CONNECTION aN 220 240 Remote control panel N B Possible connection in any micro line point 110 1S wwwsistemair it rif 01 2008 ENG Electronic control systems INSTALLATION i central vacuum systems TABLE REMOTE CONTROL PANEL TABLE REMOTE CONTROL OANEL ARTICLE COLOUR MATERIAL PACKING pcs 4200 2 _ ALUMINIUM PLASTIC a ANTHRACITE PLASTIC WALL REMOTE CONTROL PANEL ARTICLE COLOUR MATERIAL PACKING pcs anthracite PLASTIC ELECTRIC CONNECTION Connection to system s Micro Line Remote control panel L power supply V 220 240 N Connection of outlet cable for mainte nance warning signal N O contact normally open max 12 Volt 0 10 A N B Use of this signal is optional Power supply to central vacuum unit optional use v L Connection to the central vacuum 220 240 unit s micro line signal cable 111 rif 01 2008 ENG www sistemair it ET i MOUNT PLATES AND INLET VALVES safety aesthetics INE www sistemair it Mounting plates extension kits Inlet valves domestic mop board suction inlet nr Te eo TRA APA ANANA AN aka aa ia E j PHAR AH mi w gui i Pit pana
16. 23 Wheels 55 rif 01 2008 ENG www sistemair it PROFESSIONAL Central vacuum unit Series TECNO Block Mini Block Maxi FITTING THE CENTRAL UNIT CONNECTION TO THE PIPING NETWORK No particular attachment is needed although you The inlets for the connection to the piping network should ascertain that the selected installation area and air vent piping to the outside can be positioned has the minimum requirements for a correct and either on the left or right of the central unit safe positioning without incongruities that would make the central unit instable a solid resting surface a perfectly flat surface a surface unaffected by vibrations MEASUREMENT TABLES AND TECHNICAL DATA TECNO Block Mini ARTICLE TECNO Block Mini NO YES Central unit with self cleaning mm vacuum attachment 63 63 Vent grate 20 28 gt X IP insulation level Supply Volt ac 220 240 220 240 Frequency Motor power 1 5 1 5 Absorption A 6 9 6 9 Supply sockets Volt dc 12 12 Maximum air flow Filtering surface areas Dust container capacity Litres 45 45 Air vent YES YES 2 EN Discharge pipe Air discharge silencer YES YES e Weight 110 134 2772 Measurement Measurement mm Measurement C mm Measurement D mm 430 430 Measurement E mm 9
17. 81 rif 01 2008 ENG www sistemair it ACCESSORIES TABLE Resistive divider with 4 inlets Quantity 1 piece 2 Retention valve for motor coupling Quantity 1 piece 3 Retention valve for motor coupling Quantity 1 piece 4 Retention valve for motor coupling Quantity 1 piece 2 air vent silencer Quantity 1 piece 3 air vent silencer Quantity 1 piece Sa 4 air vent silencer Quantity 1 piece www sistemair it ART ARTICLE 3301 4 0110001 0110003 0110002 11001 11002 11003 Li INDUSTRIAL Dust Separators Blowing Power Units Range Peripherals of central units Blowing power units 0600050 0600060 060008Q 0600050 060006QE 060008QE rri rif 01 2008 ENG Dust Separators Blowing Power Units Range Peripherals of central units INDUSTRIAL n central vacuum systems SELECTION AND CALL BOARDS MOTOR START UP The control panel for the start up call selection is used when more than one standard motor without an electronic speed converter is installed on a single system The internal electronic system installed on the micro switch line using the resistive divider art 3301 4 aims to control turning on and off one or more of the system s motors according to the number of inlet valves used and to control the number of operational hours of each motor body I
18. STANDARD SQUARE MOUNTING PLATE 10 ARTICLE 1450 4E DESCRIPTION Packing pieces STANDARD MOUNTING PLATE elbow connector with cover STANDARD SQUARE MOUNTING PLATE 10 ARTICLE 1450 5E DESCRIPTION STANDARD MOUNTING PLATE straight connector with cover FLOOR MOUNTING PLATE Packing pieces ARTICLE 1450 2E DESCRIPTION MOUNTING PLATE elbow connector Packing pieces FLOOR MOUNTING PLATE ARTICLE DESCRIPTION Packing pieces 1450 3E rif 01 2008 ENG MOUNTING PLATE straight connector 117 www sistemair it Tm MOUNT PLATES AND INLET VALVES Mounting plates for inlet valves FLOOR MOUNTING PLATE ARTICLE DESCRIPTION Packing pieces 1450 2 ARTICLE BODENEINBAUDOSE MOUNTING PLATE elbow connector DESCRIPTION FLOOR MOUNTING PLATE Packing pieces 1450 3 ROUND MOUNTING PLATES The round mounting plates are suitable for all inlet valves which has been projected for the installation on plasterboards concerning the thickness of 12 mm or 24 mm Each model has set notches for the pre wired conduit N B Mounting plates suitable for use with 0 50 pipes 05 2 8 05 2 N 3 3 x 120 MOUNTING PLATE straight connector Packing pieces 2 ROUND MOUNTING PLATES N 3 3 x 120 n 509 0
19. 3200 2MB 3200 5MB 3200 7MB 3200 9MB ARTICLE Filter cartridge 1610 2 Quantity 1 piece Dast bags wj Quantity 1 piece 63 air vent silencer 110002 Quantity 1 piece J 0 3 air vent silencer Quantity 1 piece 11002 Compressor for 040002 self cleaning Quantity 1 piece Solenoid valve for 040016 self cleaning Quantity 1 piece ie Electronic pressure KE switch for self cleaning Quantity 1 piece Electronic board for self cleaning Quantity 1 piece Motor start up board Quantity 1 piece Call selection board Quantity 1 piece Timer for self cleaning 040020 Quantity 1 piece Resistive divider card for 4 inlets Quantity 1 piece www sistemairit rif 01 2008 ENG SPARE PARTS central vacuum systems SPARE PARTS FOR INDUSTRIAL SERIES SISTEM AIR spare parts are individually packed BLOWING POWER UNITS SPARE PARTS DUST SEPARATORS SPARE PARTS Blowing power units Separators spare parts ART 3200 0 3202 1 3200 0A 3202 1A MODEL 0600050 0600060 0600080 060005QE 060006QE 0600080 06001 00E MODEL LT 80 LT 160 IT8 CA ARTICLE Polyester filter cartridge Quantity 1 piece Dast Bags pti Quantity 20 pieces 1614 3 5 Compressor for 4047 self cleaning 1610 4 Retention valve
20. 5 15 6700 220 240 14 184 SA 100 7 1 21 6700 220 240 14 184 100 220 240 SA 200 220 240 SA 200 220 240 SA 400 220 240 450 m SA 400 BEARER Er 220 240 TECNO Activa Evolution The units of the TECNO Generation series can be connected to central units of the TECNO Generation series can be the piping system either from the left or from the right also installed in humid or dusty locations possible with the sistem case Thanks IP 44 protection the rif 01 2008 ENG www sistemair it i DOMESTIC CONNECTION TO THE PIPING NETWORK Silencer pe Discharge pipe Vacuum hose PERFORMANCE GRAPHS Vacuum mmH20 3500 ELECTRIC CONNECTION MINI TE TA Generation MEDIA TE TA Generation 50 TE TA Generation 3500 3000 7 2500 2000 A 3000 I I I I I I 2500 2000 1500 E 1500 1000 500 1000 500 I I I zl I I I I I I E I I I T I I 0 50 100 150 200 250 300 Air Flow m3 h Vacuum 200 TE TA Generation mmH2O 3500 EUREN 3500 3000 3000 2500 4 4 b b l 4 2500 2000 pc 2000 1500 2 1500 1000 Neate 500 n nn ns 500 0 50 100 150 200 250 300 Air Flow m3 h 16 Ss www sistemair it V
21. Maximumno of Maximum Computer Dust container Filtering surface Powersupply Motor power Maximum air areas sockets number of maintenance capacity Litres areas cm Volt AC Kw flow m h operators TECNOSTAR 16600 220 240 1 4x2 for two separate micro lines for one single micro line COMPUTER FOR MAINTENANCE CYCLES Emptying with handle Handle releasing dust Clean filter alarm container Thanks to its sound deadening case the central unit Tecno Star offers a high degree of noiselessness 23 rif 01 2008 ENG www sistemair it i DOMESTIC DUST CONTAINER ON WHEELS Dust bag PERFORMANCE GRAPHS Vacuum TECNOSTAR mmH20 1 MOTOR 3500 3000 2500 2000 1500 1000 500 0 50 100 150 200 250 300 Air Flow m3 h EXAMPLE OF POSSIBLE USES Electric layout 1 1 Motor with 2 Micro line Micro line 15 Floor Micro line Ground floor 24 www sistemair it Central vacuum Series TECNO Star TWO MOTORS WITH SEPARATE START UP Connection for micro line 12 V dc for 1 motor Connection for micro line 12 V dc for 2 motors Connection of power cable Connection of outlet cable for auxiliary main tenance warning signal contact nor mally open max 12 Volt 0 10 A N B Use of this signal is optional Vacuum TECNOSTAR mmH20 2 MOTORS 3500 3000 2500 2000 1500 1000 500 0
22. central vacuum Systems OUT exhaust to the exterior IN from the dust separator 1 Air vent connector 2 Vacuum connector 3 Electric motor 4 Protection cover 5 Motor control panel 6 Panel for regulating motor speed on pre fitted models 7 Vacuum pump unit 8 Control panel 9 Base 79 www sistemair it 80 INDUSTRIAL Motor fitting No particular attaching is required However you will have to check that the selected area for installation has the following minimum requirements to be correctly and safely positioned a solid resting surface a flat horizontal surface with no irregularities a surface unaffected by vibrations MEASUREMENT TABLES AND TECHNICAL DATA Blowing power units Dust Separators Blowing Power Units Range Peripherals of central units Electronic speed converter NO NO NO YES YES MES YES Frequency Hz 50 60 50 60 50 60 Motor power kW 2 2 4 Absorption A 5 8 10 5 14 5 19 8 Socket supply Volt dc 12 12 12 12 12 12 12 Maximum air flow m h 300 460 590 210 340 300 450 280 650 280 970 Air vent YES YES YES YES YES YES NES Weight kg 73 97 141 Measurement A mm 540 540 595 540 540 595 595 Measurement B mm 690 690 810 690 690 810 810 Measurement C mm 600 640 800 600 600 800 830 Measurement D mm 190 175 202 5 190 190 Measurement E mm 160 190 190 160 160 Measurement F mm 140 100 140 140 140 140 1
23. 116 125 125 118 118 118 117 117 116 117 116 117 120 120 128 119 127 127 127 127 127 127 127 127 126 126 ARTICLES CONTENTS central vacuum systems ARTICLE DESCRIPTION 1457 1 1459 5 1464 0B 1464 1B 1464 2 1464 2B 1464 3 1464 5 1464 6A 1464 6B 1464 6G 1541 0 1542 0 155173 1551 4 1552 0 1553 0 15532 1553 4 15535 155750 15573 1557 1 1557 3 1558 0 1561 0 1562 0 1563 0 1563 1 1563 2 1565 0 1566 0 1567 0 1568 0 1569 0 1610 0 1610 1 1610 15 1610 2 1610 4 1610 5 1610 7 1610 9 1611 10 1611 11 1611 15 1611 3 1611 4 oles 1611 6 1611 7 1611 9 1612 4 16125 1612 8 1612 9 1612 10 1613 10 1613 11 1613 13 1613 14 1619 Inlet valve extension Inlet valve with chase box diam 2 mm Square inlet valve white colour Square inlet valve ivory colour Vacpan white colour Square inlet valve aluminium color Vacpan black colour Vacpan aluminium color Installation kit for plasterboard Black Installation kit for plasterboard White Installation kit for plasterboard Silver Generation inlet mod ABB Elos Generation inlet mod ABB Chiara Generation inlet mod Legrand Vela bianca Generation inlet mod Legrand Vela nera Generation inlet mod Ave Noir Generation inlet mod Vimar Idea Nera Rond Generation inlet mod Vimar Idea Rond White Generation inlet mod Vimar Idea Plana Generation inlet mod Vimar Next Generation inlet mod Gewiss Playbus Generati
24. 60g 49 rif 01 2008 ENG www sistemair it PROFESSIONAL Central vacuum unit Series TECNO Block Mini TECNO Block Maxi www sistemair it Professional LES x C viw s E m h i A EA CT We LEN EE mero C 6 SIE RES le NUR ES 2 ICG PROFESSIONAL Central vacuum unit Series TECNO Block Mini TECNO Block Maxi 52 Linea TECNO Block Mini without self cleaning Linea TECNO Block Mini with self cleaning Up to 600 m 1 Operator Qo RECOMMENDED INSTALLATION The central units are fitted with a connection for the air vent piping which is essential for sending the micro dust that the filter cartrid ge cannot contain outside They should be installed in service rooms such as garages cel lars etc and protected from extreme weather conditions and excessive temperature changes You should choose areas at some distance from heat sources such as heaters or central heating IP 20 insulation level At the planning stage it is advisable to identify the best location for the central unit with respect to the system leaving a reasonable amount of space for installation use maintenance and a correct re circulation of air around the central unit In the event of a system on several floors it should be installed on the bottom floor www sistemair it INSTALLA
25. 7047 3 Plastic Pcs 1 Colour Material Packing 7047 4 Plastic Pcs 1 040 BRUSH FOR LIQUIDS Colour Material Packing 7033 8 Plastic 48 CM 40 BRUSH WITH BRISTLES FOR FLOOR USE Material 7047 2 Plastic 40 CREVICE TOOL 40 OVEN CLEANING KIT Material Packing 000000000000 Article Colour S Sd 555 Se p EZINA 00 7032 3 Stee Meta Pcs 1 www sistemair it L KITS AND ACCESSORIES SPECIAL CLEANING SEPARATORS The special cleaning separators are accessories that you can use every time you have to vacuum liquids or ash that must not get into the vacuum piping network They are fitted with wheels for movement that allow you to easily and rapidly mo ve and empty it Special Cleaning LIQUID SEPARATOR ON WHEELS COMPLETE WITH ACCESSORIES Article Colour Material Packing Grey Plastic Pcs 1 EQUIPMENT 32 hose for connection to system brush for liquids Article 610 7033 7 EQUIPMENT 32 flexible hose for connection to the system 140 SS www sistemair it Colour Steel 20 LITRE METAL ASH SEPARATOR ON WHEELS Material Packing Metal Pcs 1 rif 01 2008 ENG Reel accessories REEL ACCESSORIES The reel accessories ensure ease in cleaning industrial envi ronments thanks to the fact
26. Brush for liquids with rubber spatulas 30 cm Brush for mattresses and upholstery Brush for pipes and balks Carpet beater brush Carpet beater brush with 12 V battery Case Cover for Media unit Case Cover for Mini unit Central vacuum unit TECNOBLOCK 4 kW 380 Volt with self cleaning Central vacuum unit TECNOBLOCK 2 2 kW 380 Volt with self cleaning Central vacuum unit TECNOBLOCK 2 2 kW QE 220 240 Volt Central vacuum unit TECNOBLOCK 2 2 kW QE 220 240 Volt with self cleaning Central vacuum unit TECNOBLOCK 2 2 kW QE 380 Volt Central vacuum unit TECNOBLOCK 2 2 kW QE 380 Volt with self cleaning Central vacuum unit TECNOBLOCK 2 2kW 380 Volt Central vacuum unit TECNOBLOCK 4 kW QE 380 Volt Central vacuum unit TECNOBLOCK 4 kW QE 380 Volt Plus Central vacuum unit TECNOBLOCK 4 kW QE 380 Volt with self cleaning Central vacuum unit TECNOBLOCK MINI QE 1 5 kW 220 240 Volt Central vacuum unit model MEDIA PLUS TA Generation for 250 m Central vacuum unit model MEDIA PLUS TE Generation for 250 m Central vacuum unit model MEDIA TA Generation for 150 m Central vacuum unit model MEDIA TE Generation for 150 m Central vacuum unit model MINI TA Generation for 150 m Central vacuum unit model MINI TE Generation for 150 m Central vacuum unit model SA050 0TA Generation for 150 m Central vacuum unit model 5 050 Generation for 150 www sistemair it Catalogue PAGE 135 75 75 153 198 151 153 193 75 75 153 153 104 10
27. C Minimum working temperature pipe Cat 2 5 C Maximum working temperature pipe Cat 1 60 C For the cables The conduction wires are IMQ certified red and No7VK type do not propagate fire with 1 mm2 section Legislation IEC 20 20 20 22 20 37 IECSUINFEI 985752 CENELEC H D21 FIRE FIGHTING COUPLINGS To be applied everywhere that fire prevention legislation is in ef fect Fire resistance cat REI 180 certified 180 min The fire fighting couplings are used to seal the crossings of enginee ring resin pipes PVC PE PP in fire prevention compartments At a temperature of approx 150 C the internal intumescent material starts to expand thus increasing its own volume by about 10 times developing a considerable pressure enough to activate the fire resi stance closure system that keeps in burning gases Read the safety instructions before use To use them the fire stop couplings must be used in compliance with fire resistance certificates both in number and orientation as well as fi xing system GLUE Certified PVC based glue dissolved in solvent Basic ingredients PVC resins Special ingredients organic solvents Solder the glued junction Gluing is equally resistant to chemical agents and has the same me chanical properties as hard PVC Its controlled viscosity means it can easily be applied without glu ing Ideal for longitudinal junctions on hard PVC pipes and the assembling of PVC
28. Lower elbow chrome handle 40 pair of 32 extension chrome fittings chrome telescopic extension 32 Hose extensions in plastic pair 32 Accessory holder 10 pieces Mini kit accessory holder 4 pieces Accessory trolley Hose reel trolley 32 Hose reel trolley 40 Loose hose reel 32 Loose hose reel 40 Clothes brush with bristles Dust brush with bristles Brush for mattresses and upholstery Crevice tool Radiator brush Floor brush 37 cm Brush floor 30 cm Floor brush 48cm 40 Dust brush 48 cm 40 Crevice tool 0 40 Hose fitting extension 32 Brush for animals Sistem Case Case Cover for Mini unit Case Cover for Media unit PVC inspection screw cap 80 Hose adaptor 63 80 Wolly 150 central unit Wolly 150 central unit Bags for Wolly Sistem Cube central vacuum unit rif 01 2008 ENG Catalogue PAGE 134 133 134 139 132 140 136 136 135 140 139 135 135 135 185 135 135 137 137 139 136 137 136 137 137 139 139 137 137 139 139 137 137 137 138 138 138 141 141 141 141 135 136 136 136 136 135 135 139 139 139 137 136 103 103 103 105 105 27 27 150 ARTICLES CONTENTS ARTICLE DESCRIPTION 8401 0 8402 0 8403 0 8406 0 8500 0 8500 1 8510 0 8510 1 8511 0 8512 0 8600 0 8600 0R 8600 2 8710 0 8720 0 8900 0 8900 1 9016 0 9016 1 9016 7 9225 1 922932 9225 9 9500 0 Jolly spare motor Jolly spare dust bags pack of 5 Jolly spare ca
29. Research and development highlight Sistem Air s com mitment to the central vacuum market The strong financial position of our com pany can guarantee our foreign client stability and growth Meanwhile Sistem Air has acquires a much greater knowledge of worldwide market requirements This cultural exchange has made our R amp D easier Our IT systems with a continually updated web site provides access to all for updates on promotions and about new products and services www sistemair it CEE Countries Extra CEE Countries Austria Africa Africa del Sur Tunisia Cameron Denmark Australia Finland Bosnia and Herzegovina France Brazil Germany Canada Greece China Ireland Croatia Portugal Kosovo Czech Republic Liban Slovakia Moldova Slovenia Norway Espana Romania Spain Russia Hungary Serbia United States 5 JIG CENTRAL VACUUM SYSTEMS INDEX DOMESTIC Central Vacuum Cleaners from 30 to 450 m Tecno Evolution Generation line Tecno Activa Generation line Central Vacuum Cleaners up to 450 2 operators Serie TECNO STAR Central Vacuum Cleaners for vertical building up to 120 m Sistem CUBE Built in Central Vacuum Cleaners for vertical building up to 300 m e WOLLY DOMESTIC Central Vacuum Cleaners for pre built houses System JOLLY PROFESSIONAL Central Vacuum Cleaners up to 600 m e Tecno Blo
30. Website www sistemair it e Email info sistemair it MPIANTO CENTRALIZZATO DI ASPERAZIONE SISTEM AIR INFORMAZIONE PUBBLICITARIA IGIENE COMFORT all i insegna della SEMPLICITA him h orn meli bci viann IL a 1 K Ta RPM TRE c RU S II RN UE ORB pon DAL D dd TUN Rd Pumaq Ge rw pie p __ r _ hec cranes esas wet Ds iR ar TIE a E Edi A ee N us LSS pe ee 1 supp aes qii da potyas ue rs ha a wd kou 2 i m arum Wi Lom mud sirena i Fagop apan km papapaq eem Bo P i __ __ __ a o amm ee gee m icem ee ups m _ or m ee u zd acm eS BERT Aud audae __ dias eee ee ji __ mur mpra HB perii d dem mill am mediae una mi Sa ee AOUT lass ad ee Pape N en pen N S A N C CLEANERS we L PT MR ZAN I X
31. on balconies or even in airing cupboards he central units can be connected to the piping network with dust entrance from either the right or left hey are fitted with safety heat sensors to protect the motor and with automa tic shut down or restart in the event of overheating hey comply with the high electric and mechanical safety standards imposed by the IMQ body and have received the approved label The polyester filter cartridge is certified BIA USG and can be washed with water he product stands out for its Level 2 insulation category it does not require to be earthed Using the template provided art 4300 0 when setting up the system will ensure that the unit is correctly installed without problems errors or time wa sting TECNO Activ Generation also has a built in computer to control and manage the maintenance cycles it offers the possibility of connecting to an auxiliary modem as a maintenance warning as well as the possibility of a connection to the remote control panel in order to view the maintenance cycles TECNO Activa TA comes with a 3 year warranty MAIN CHARACTERISTICS The construction is entirely made vibration proof sound proof plastic and with rust proof screws and bolts It offers maximum quietness when running thanks to the enclosure of the motor in a vibration proof hood It is fitted with double protection electronic power and control board with fuse block switches both on the m
32. phase electric brush motor and rotor packs Heat safety probe to protect the engine group with automatic shut down and restart Double protection electric control board with fuse block switches both on the main and secondary circuit 12V dc power to inlet valves BIA USG certified polystyrene filter cartridge washable with water for filtering surfaces see individual models Computer for maintenance cycle control only on TA series with LED signal when dust container is full filter cartridge to be cleaned and motor mainte nance Arrangement for connection to an auxiliary maintenance warning modem only TA range Option of connecting to remote wall panel art 4200 6 that can be connected to all the central unit models Warning When as a result of particular installation needs the central vacuum unit is placed in upper floors of a building with respect to the piping network attic etc itis essential to use a central vacuum unit of a higher category than the one suitable for the surface area to be cleaned we would advise you to consult with SISTEM AIR s design office N B if a fuse has to be replaced make sure you use the correct amperage and that it is a SB fuse motor Stick rigorously to IEC and national power supply regulations during installation rif 01 2008 ENG DOMESTIC central vacuum Systems EX NON F Computer maintenance only with Tecno
33. 1 0110001 Q 2 retention valve for the coupling of more than one motor Control panel for cascade start up of 3 motors 90 ENS Jwww istemairit rif 01 2008 ENG Dust Separators Blowing Power Units Range Peripherals of central units INDUSTRIAL central vacuum Systems e MM Max number of operators 4 Max no of sockets 100 ARTICLE PRODUCT DESCRIPTION Quantity 160 litre dust separator 4 445907 380 V 4 kW blowing power unit complete with control panel 3 metal silencer 0110003 3 retention valve for the coupling of more than one motor Control panel for cascade start up of 2 motors ARTICLE PRODUCT DESCRIPTION Quantity PAPAS 1060litre dust separator with self cleaning filter 01380 380 V 7 5 kW electronic blowing power unit complete with control panel 4 metal silencer Control panel for the modulation of the electronic motors ARTICLE PRODUCT DESCRIPTION Quantity 212872774 160 litre dust separator with self cleaning filter 4 444907 380V 4 kW electronic blowing power unit complete with control panel 3 metal silencer 0110003 3 retention valve for the coupling of more than one motor 3301 6 Control panel for cascade start up of 2 motors 1 91 rif 01 2008 ENG www sistemair it INDUSTRIAL Dust Separators Blowing Power Units Range Peripherals of central units Max number of operators 6 Max no of sockets 110 ARTICL
34. 1464 2B 1464 1B 1464 0B 1450 5E 1450 4B 1450 4E 1450 5B 6050 0F 1400 1 1400 0 1450 16 1850 0F 1863 0F 1110 1 1150 1 Plastic end handle with pressure switch pressure switch for self cleaning Pre wired conduit 2x1mm 100 m Pre wired conduit 2x1mm 50 m Pre wired conduit 2x1mm 25 m PVC Ball valve for manual division 100 PVC ball valve for manual division 50 PVC ball valve for manual division 63 PVC Ball valve for manual division 80 PVC inspection screw cap 50 PVC inspection screw cap 63 PVC inspection screw cap 80 PVC pipe 2 2 m thick 2 m bars 50 PVC pipe 3 mm thick 2 m bars 63 PVC pipe 3 mm thick 2 m bars 80 PVC pipe cutter 100 PVC pipe cutter 63 PVC pipe 3m thick 2 m bars 100 PVC wye 45 female female female 100 PVC wye 45 female female female 50 PVC wye 45 female female female 63 PVC wye 45 female female female 80 PVC wye 45 male female female 100 PVC wye 45 male female female 50 PVC wye 45 male female female 63 PVC wye 45 male female female 80 Radiator brush Rectangular monting plate 2 elbow connector Rectangular mounting plate 90 elbow connector with plaster guard Rectangular mounting plate straight connector with plaster guard Rectangular mounting plate straight connector with plaster guard 2 Resistive divider card with 4 inlets Rotating nozzle for dust separator LT 160 with self cleaning system Round mounting plate Round mountin
35. 7030 02 7030 03 7030 01E 7030 02E 7030 03E 7030 3 7030 3E 7030 4 7030 4E 7030 5 7030 5E 7031 0 7031 1 7081 2 7032 0 DESCRIPTION Central vacuum unit TECNOBLOCK 4 kW 380 Volt with self cleaning Central vacuum unit TECNOBLOCK 4 kW 380 Volt Central vacuum unit TECNOBLOCK 2 2 kW 380 Volt with self cleaning Dust separator LT 160 Dust separator LT 160 with self cleaning Electronic board for 3 motor starter system Electronic card for motors with circuit board Electronic board for 8 motor starter system Substitute circuit board for Tecno Block unit Pressure switch for self cleaning Resistive divider card with 4 inlets Speed modulation circuit board Electronic board for 2 motor starter system Electronic card for self cleaning Electronic card for automatic filter cleaning Vacuum gauge for system testing PVC wye 45 male female female 100 PVC wye 45 female female female 100 PVC wye 45 male female female 50 Derivation Pipe 45 Male Male Male 50 PVC wye 45 female female female 50 PVC wye 45 male female female 63 Derivation Pipe 45 Male Male Male 60 PVC wye 45 female female female 63 PVC wye 45 male female female 80 PVC wye 45 female female female 80 PVC pipe cutter 100 PVC pipe cutter 63 Spare wheel for pipe cutters Wall remote control panel for central vacuum units Table remote control panel aluminium colour Table remote control panel anthracite colour Wall remote
36. 7100 1 3200 9MB 3200 3MB 3200 1MB 3200 2MB 3200 4MB 3200 5MB 3200 0MB 3200 6MB 3200 8MB 3200 7MB 3115 1MB 3109 1TA 2109 dE 3108 1TA 3108 1TE 3107 1TA 3107 3110 1TA DESCRIPTION 12 V battery for carpet beater brush 2 2 kW blowing power unit with 380 Volt control panel 2 2 kW blowing power unit with 380 Volt electronic board 2 check valve for motor connection 2 metal silencer 220 240 V compressor for self cleaning 3 check valve for motor connection 3 metal silencer 4 kW blowing power unit with 380 Volt control panel 4 kW blowing power unit with 380 Volt with electronic board 4 check valve for motor connection 4 metal silencer 45 elbow PVC female female 100 45 elbow PVC female female 50 45 elbow PVC female female 63 45 elbow PVC female female 80 45 elbow PVC male female 100 45 elbow PVC male female 50 45 elbow PVC male female 63 45 elbow PVC male female 80 5 5 kW blowing power unit with 380 Volt control panel 5 5 kW blowing power unit with 380 Volt electronic board 7 5 kW blowing power unit with 380 Volt electronic board Accessory holder 10 pieces Accessory kit for oven Accessory trolley Adapter for square mounting plate Aluminium alloy pipe 3 m 6060 63 Aluminium alloy pipe 3 m 50 Ash separator in metal Bags for Sistem Cube Bags for Wolly Battery charger for carpet beater brush Brush floor 30 cm Brush for animals Brush for liquids 0 40
37. Activa Generation central units 2 Soundproof dome 3 Motor body 4 Electronic card housing panel 5 Starter button 6 Activation signal cable Micro Line 7 Electric power cable 8 X Auxiliary maintenance signal cable only for Tecno Activa Generation central units 9 Air vent 10 Dustinlet 11 Filter cartridge 12 Machine body 13 Handle and closure hook 14 Conveyor cone 15 Dust container 17 qu www sistemair it DOMESTIC INSTALLING THE CENTRAL UNIT The central unit is mounted on the supplied mounting bracket This must be securely and per manently fixed to a wall with appropriate plugs considering that the overall weight can reach as much 7 8 times the weight of the central unit itself See Technical Data table MEASUREMENT TABLES AND TECHNICAL DATA TECNO Evolution Generation Central vacuum Series Tecno Activa Tecno Evolution TECNO Activa Generation 3107 1TE 3108 1TE 3109 1TE 3110 1TE 3112 1TE 3113 1TE 3115 1TE 3107 1TA 3108 1TA 3109 1TA 3110 1TA 3112 1TA 3113 1TA 3115 1TA 50 60 50 60 150 60 Frequency Hz 50 60 50 60 50 60 50 60 50 60 UJ MODEL MINI MEDIA MEDIA SA50 SA 100 SA200 SA400 f MINI MEDIA TE PASTE ESTE TE PLUS TA Computer maintenance NO NO YES YES Vacuum attachment 50 50 50 50 Insulation level 44 44 44 44 44 44 Pow
38. PVC ball valve for manual division 50 2050 1 PVC ball valve for manual division 63 2050 2 PVC Ball valve for manual division 80 2050 3 PVC Ball valve for manual division 100 3010 0 45 elbow PVC male female 100 3010 1 45 elbow PVC female female 100 3050 0 45 elbow PVC male female 50 3050 1 45 elbow PVC female female 50 3050 0F _ Elbow pipe 90 Male Male 50 3050 1F Elbow pipe 45 Male Male 50 3063 0 45 elbow PVC male female 63 3063 0F Elbow pipe 90 Male Male 63 3063 1 45 elbow PVC female female 63 3063 1F Elbow pipe 45 Male Male 60 3080 0 45 elbow PVC male female 80 3080 1 45 elbow PVC female female 80 3107 1TA Central vacuum unit model MINI TA Generation for 150 m 3107 1TE Central vacuum unit model MINI TE Generation for 150 m 3108 1TA Central vacuum unit model MEDIA TA Generation for 150 m 3108 1TE Central vacuum unit model MEDIA TE Generation for 150 m 3109 1TA Central vacuum unit model MEDIA PLUS TA Generation for 250 m 3109 1TE Central vacuum unit model MEDIA PLUS TE Generation for 250 m 3110 1TA Central vacuum unit model SA050 0TA Generation for 150 m 3110 1TE Central vacuum unit model SA050 0TE Generation for 150 m 3112 1TA Central vacuum unit model SA100TA Generation for 250 m 3112 1TE Central vacuum unit model SA100TE Generation for 250 m 3113 1TA Central vacuum unit model SA200TA Generation for 350 m 3113 1TE Central vacuum unit model SA
39. a view to simplifying the purchase of material for fitting the system as much as possible For systems in buildings with standard layout it is possible to have all the material available with the certainty of being able to complete the piping network without further additional installation material Warning Only the installation material is included in the kit because the inlet valves are part of the system and should therefore be selected from the right sec tion of the catalogue Installation kit with rectangular mounting plates parts no 1450 0 Art Art Art Art Art Art Art 1450 0 1850 0 3050 0 3050 1 4050 1 1150 1 5050 4 ASW YG CO 22 2 ARTICLE No of sockets mounting PVC pipe elbow FFelbow Pieces FF derivation Coupling Vent grate Tm plate Pieces m Pieces Pieces Pieces Pieces m Pieces Installation kit with square mounting plates parts no 1450 4B Art Art Art Art Art Art Art 1450 48 1850 0 3050 0 3050 1 4050 1 1150 1 5050 4 JU ARTICLE No of sockets mounting PVC pipe MF elbow _ FFelbowPieces FF derivation Coupling Vent grate Conduit Special glue plate Pieces m Pieces Pieces Pieces Pieces m Pieces ww p 7030 3E 3 3 20 9 12 3 9 1 25 1 7030 4E 4 4 28 12 16 4 12 1 37 5 1 7030 5 5 5 36 15 20 5 15 1 5 1 108 DP wwwsistemair it
40. central unit DOMESTIC central vacuum systems CENTRAL UNIT SELECTION TABLE The Wolly central unit has been projected to be placed inside our outside the house It accepts network pipes with 40 mm for installations with maximum 3 inlets or 50 mm 4 and the air discharge takes place from the frontal panel or carried into pipes Maximum surface MODEL ARTICLE Maximum Operators Vacuum Airvent Dustbag Filtering Power supply Motor Maximum air inlet valves maximum attachement mm capacity surface V ac power flow mm 1 cm kW m h Wolly 150 8200 0 2840 220 240 1 3 Wolly 250 8200 1 2840 220 240 1 4 WOLLY BUILT IN CASE ART 7101 0 The Wolly built in box has to be walled in during the arrangement of the installation A special mortar protection cover will protect the box during the following walling jobs In order to finish the installation you just need to insert the central unit into the box RECOMMENDED INSTALLATION The flexibility of installation thought for Wolly unit is total During the realization phase of the system the different solutions are the following dusts entrance right or left discharge in right left pipe air discharge in frontal way or in pipe use of plant pipes 40 mm or 50mm WOLLY FITTING COVER ART 7101 1 It is matchable at pleasure depending on the requirements The cover allows you to close and protect without necessity of further accessories th
41. e a NISI W ololtt Alk mm SA OAIN AANA ANA rYn OO EXNIDI IONS ana CENTRAL VACUUM SYSTEMS spreading the culture z of the system SISTEM AIR invests a great deal of effort in trade shows and exhibitions in order to standardize its message to the public Sistem Air proposes two kinds of exhibitions The first is aimed at the end user in order to stimulate their awareness of the brand and the benefits offered by the system The second is specifically for installers of the system aiming at informing them on how to correctly install the different systems and informing them of upco ming new products and innovations In our regularly scheduled meetings our strategy and our goals are constantly mo nitored with respect to the needs of tomorrow s market Mm LIN manda d ie paya E w mei Uri monda dl Dieren Central Vacuum Systems the Sistem Air brand worldwide Think globally act locally This has resulted in us exporting products to a continually increasing number of areas around the globe This expansion has been achieved thanks to our clever positioning of importers that guarantee the quality of the Si stem Air brand They are expected to promote our brand clearly and innovatively On the other hand we can guarantee them a solid business relationship based on seriousness and stability
42. female PVC DERIVATION m 4063 0 63 45 male female female PVC DERIVATION 4080 0 Q 80 45 male female female PVC DERIVATION 4010 0 100 45 male female female PVC DERIVATION 4050 1 Q 50 45 female female female PVC DERIVATION 63 45 female female female PVC DERIVATION 80 45 female female female PVC DERIVATION 100 45 female female female PVC DERIVATION 104 DP wwwsistemair it rif 01 2008 ENG Installation materials INSTALLATION central vacuum Systems ARTICLE DESCRIPTION PACKING pcs 1150 1 PVC COUPLING FOR LINEAR JUNCTIONS 50 PVC stop coupling 100 1163 1 0 63 PVC stop coupling 1180 1 80 PVC stop coupling 1110 1 100 PVC stop coupling PVC PIPE ADAPTER ARTICLE DESCRIPTION PACKING pcs 6063 3 9 50 63 hose adaptor p 8080 3 63 80 hose adaptor 1 1010 3 2 80 100 hose adaptor 1 PVC EXPANSION JOINTS ARTICLE DESCRIPTION PACKING pcs 5050 0 9 50 expansion joint 5050 2 9 63 expansion joint PVC SCREW CAPS FOR INSPECTING ARTICLE DESCRIPTION PACKING pcs 5050 1 0 50 PVC inspection screw cap 1 6063 1 9 63 PVC inspection screw cap 8080 1 g 80 PVC inspection screw cap AIR VENT GRATE 7 ARTICLE DESCRIPTION PACKING pcs 2 5050 4 g 50 exhaust vent 5063 4 9 63 exhaust vent AIR VENT SILENCER ARTICLE DESCRIPTION PACKING pcs 110001 standard o 50 2 PVC silencer 1
43. it 149 SPARE PARTS SPARE PARTS FOR DOMESTIC SERIES SISTEM AIR spare parts are individually packed TECNOSTAR CENTRAL UNIT SPARE PARTS TECNO Star ART ARTICLE TECNO Star Filter cartridge Quantity 1 piece Qu Bags p Quantity 20 pieces 1613 13 Motor Quantity 2 pieces Motor brushes Quantity 2 pieces gt gt Motor start up board Quantity 1 piece Electronic board for computer Quantity 1 piece 63 air vent silencer Quantity 1 piece WOLLY CENTRAL UNIT SPARE PARTS ART ARTICLE Filter cartridge 8200 1 Wolly 300 SISTEM CUBE CENTRAL UNIT SPARE PARTS Filter cartridge Quantity 1 piece Bags Quantity 20 pieces Motor Quantity 2 pieces Motor brushes Quantity 2 pieces Electronic board for computer Quantity 1 piece Quantity 1 piece Motor Quantity 2 pieces Bags Quantity 20 pieces Electronic board for computer OFT START SYSTEM WAALA Quantity 1 piece Motor brushes Quantity 2 pieces 1611 10 150 www sistemair it ARTICLE Sistem CUBE ART 8300 0 Sistem CUBE 1610 15 1614 15 1623 15 1611 15 rif 01 2008 ENG SPARE PARTS FOR DOMESTIC SERIES SISTEM AIR spa
44. mm 1457 1 Inlet valve extension 1459 5 Inlet valve with chase box diam 51 mm 1010 1 Inspection screw cap in PVC 0 100 1464 6A Installation kit for plasterboard Black 1464 6G Installation kit for plasterboard Silver 1464 6B Installation kit for plasterboard White 7030 01 Installation kit with 1 inlet valve 40 mm 7030 01E Installation kit with 1 square inlet valve 40 mm 7030 02 X Installation kit with 2 inlet valves 40 mm 7030 02E Installation kit with 2 square inlet valves 40 mm rif 01 2008 ENG Catalogue PAGE 106 139 137 135 139 127 127 127 127 127 127 127 127 118 117 124 124 124 124 124 124 128 123 123 123 125 123 123 124 124 124 124 127 124 125 123 106 123 125 105 139 157 137 141 141 137 137 136 136 126 120 126 105 119 119 119 35 35 35 35 ALPHABETIC CONTENTS i central vacuum systems ARTICLE DESCRIPTION 7030 3 7030 03 7030 3E 7030 03E 7030 4 7030 4E 7030 5 7030 5E 1450 11 8600 2 8512 0 8500 0 8510 0 8600 0 8600 0R 8900 0 8900 1 8500 1 8406 0 8510 1 8511 0 8403 0 8402 0 8401 0 8710 0 8720 0 1163 1F 7033 0 7041 5 7041 6 703927 7041 1 1611 7 1611 3 1611 4 el 1611 6 1611 10 161115 1611 9 1623 11 1613 7 1613 11 1623 7 1623 8 1613 8 1623 9 1613 9 1623 10 1613 10 1623 15 161313 1613 14 7031 70312E 7032 1 7032 2E 7040 0 1010 3 6063 3 Installation kit with 3 inlet valves Inst
45. network built with 50 mm diameter pipe and 63 mm inlet connec tor to the central unit 220 240 V ac single phase power air vent use of the system with up to 2 operators simultaneously once as the piping network has been properly installed PARTICULAR CHARACTERISTICS OF THE PRODUCT The TECNO Star range offers the possibility of connecting to the piping net work with attachments from either the right or left t is fitted with safety heat sensors to protect the motors and with automatic shut down or restart in the event of irregularities The polyester filter cartridge is certified BIA USGC and can be washed with water It is extremely quiet thanks to its large soundproof motor compartment It offers the possibility of connecting up an auxiliary maintenance warning signal optional usage The possibility of viewing the maintenance cycles from a remote control mo dem he product stands out for its Category 1 insulation category he central unit has two motors that give greater vacuum power when ne cessary Delayed start up of the second motor to avoid a high absorption while star ting The user canl obtain maximum vacuum power by using the Turbo Function due to the use of two motors on a single micro line A differentiated start up of the motors can be obtained thanks to the creation of two separate micro lines TECNO Star also has a built in computer to control and manage the mainte
46. piti i HH MOUNT PLATES AND INLET VALVES 114 NEM www sistemair it Inlet valves and their usage MOUNTING PLATES AND INLET VALVES Installation area The SISTEM AIR inlet valves meet the most wide ranging system and aesthetic needs from the domestic to industrial sector Domestic environment They stand out for their high standard of quality and because they can be matched with most decorative plaques on the market There is a vast range of sockets that can be completed with the plaque from the most common do mestic range sockets for the skirting board to be attached to the skirting board on the kitchen unit are available in the event of systems with external pipes garages attics service rooms etc you can use the external socket parts no 1459 6 Furthermore you can choose between standard or electrified flexible hoses Industrial business environment They meet the needs for application both internally and externally Frequently used industrial sockets are available with classic installation in the wall or on the floor the latter can be installed in aluminium mounting plates Criteria for selecting the sockets The inlet valves for domestic use that require finishing with aesthetic plaque have to be selected in accordance with the domestic range of electric sockets used for home systems in order to use the same kind of decorative plaque N B Check availability of the finishing plaque in the domestic r
47. seamed without internal welding with deep drawing ALUMINIUM PIPES Pipes thickness 50x1 5 mm 63x1 5 mm Material alluminium UNI EN 573 3 EN AW 6060 ALMGSI heat treated and aged Chemical characteristics UNI EN 573 3 Mechanical characteristics UNI EN 755 2 PRE WIRED CONDUIT Pre wired protective folding insulating conduit Grey with 16 mm diameter CE IMO labelling IMQ certification Complies with the following regulations EN 50086 1 1993 EN 50086 2 2 1995 A11 1998 Products conform to the essential requirements found in the B T 3 23 CEE directive and later changes Pipe with C1 base classification 3422 corrugated DOES NOT propa gate flames Further C1 classification 32 0 010 Product has no halogen as required by law IEC EN 50267 2 1 1999 and IEC EN 50267 2 2 1999 rif 01 2008 ENG INSTALLATION i central vacuum systems This kind of conduit is suitable for all those places requiring non toxic characteristics and non emission of fumes or toxic gases Reference document IEC EN 50267 1 1999 Cat IEC 20 37 2 0 5325 IEC EN 50267 2 1 1999 Cat IEC 20 37 2 1 F 5326 The same as IEC 60754 1 IEC EN 50267 2 2 1999 Cat IEC 20 37 2 2 F 5327 The same as IEC 60754 2 Suitable in cases where particular mechanical resistance is needed Crush resistance pipe Cat 3 average greater than 750 N on 5 cm at 20 C Blow resistance pipe Cat 3 average 2 joules at 5
48. sistemairit rif 01 2008 ENG Central vacuum unit Series TECNO Block Mini TECNO Block PROFESSIONAL i CONNECTION TO THE PIPING NETWORK The inlets for the connection to the piping net work and air vent piping to the outside can be positioned either on the left or the right of the central unit MEASUREMENT TABLES AND TECHNICAL DATA MODEL Central unit with self cleaning 3200 0 MB 3200 1 MB 3200 4 MB 3200 6 MB 3200 8 MB 3200 3 MB 3200 2 MB 3200 5 MB 3200 7 MB 3200 9 TECNO Block Maxi EEO TECNO Block Maxi NO YES central vacuum systems oe eee mm vacuum attachment mm 80 63 IP insulation level IP 20 20 Supply Volt ac 220 240 3 380 a EERE IESE w Motor power kW 2 2 4 Absorption A 5 8 Supply sockets Volt dc 12 Maximum air flow m h 210 340 210 360 250 450 250 530 210 340 210 360 250 450 250 530 Filtering surface areas cm 24000 24000 24000 Dust container capacity 60 Air vent YES Air discharge silencer YES YES YES YES Weight kg 186 Measurement A mm 620 Measurement B mm 550 Measurement C mm 1780 1780 Measurement D mm 630 Measurement E mm 670 670 920 Measurement F mm 75 75 100 Measurement G mm 800 800 870 Measurement M mm 75 75 75 75 78 75 75 75 78 Measurement P mm Measurement R mm Nois
49. size 30 cm x 30 cm that makes it possible to install it in very small spaces such as under the sink in a store room or on the kitchen balcony SISTEM CUBE is the best option for installing centralised vacuum systems in vertical buildings The installation foresees the use of a 40mm diameter pipe which is very useful in the case of houses with thin foundation and with a walling up template that allows the complete fitting of the system The central unit clicks into the template using special hooks Sistem Air provides Sistem Cube with three different kits complete with pre installation respectively with one two or three sockets and with all the material needed to complete the pre installation The central vacuum units of the Sistem CUBE series are designed to cope with and resolve problems in domestic environments especially in apartment buildings Built entirely of PP ABS plastic it stands out for its sturdiness and reliability together with a simple basic line MAIN CHARACTERISTICS Produced in strong plastic the Sistem Cube offers everyone the advantages of centralised vacuuming as well as the excellent adaptability of a very space saving solution Thanks to its small size it can be placed anywhere such as in the boiler room or under the kitchen sink The dust can be easily removed thanks to a practical paper bag inside the unit that can be easily and quickly pulled out As the lid on the central unit has no screws the bag can be repla
50. suction power in any professional environment and allow more than one operator rif 01 2008 ENG www sistemair it Series TECNO Block Mini TECNO Block i PROFESSIONAL Central vacuum un EMPTYING WITH HANDLE CONNECTION TO THE PIPING NETWORK Ven TONS Silencer Discharge pipe ete OY QD it I 111111111111111 dust container WAM Vacuum hose PERFORMANCE GRAPH Art 3200 1MB 3200 2MB Art 3200 0MB 3200 3MB Depending on the model selected the central units allow you to choose one of 3 speeds Choose the most suitable speed according to the ne eds and kind of system Vacuum mbar m3 h Air flow 100 200 300 400 500 0 m3 h 100 200 300 400 500 Airflow m I Vacuum mbar 450 1 2 0 3 Art 3200 8MB 3200 9MB Art 3200 7MB 3200 6MB ca N n L ca 2 m N lt Vacuum mbar mbar Vacuum 100 200 300 400 500 600 Airflow 0 m3 h Air flow ATA TREAT IE 100 200 300 400 500 L I E
51. to its different uses Magnetic thermal protection Switch for micro line to make daily main tenance easier SELECTION CRITERIA The blowing units should be selected according to the number of operators required and the specific needs of the system rif 01 2008 ENG ij LEN f central vacuum Systems MOTORS SELECTION TABLE The industrial Sistem Air vacuum motors can be used in numerous ways thanks to their flexibility in combining with other parts of an industrial central vacuum system Putting the system together can be completely personalised so please consult the chapter Guide to selecting industrial system The choice of motors should be made on the basis of the number of people using the system simultaneously and the surface area to be cleaned in order to unsure maximum duration and performance over time Depending on your needs you can choose to install a system with electric motors or fitted with electronic speed and performance management As the industrial motors are part of the system you should make your choice only after reflecting on how it will be used and the kind of system itself You should also evaluate the use of available accessories created to optimise the vacuum system s performance Should you have any doubts our representatives will be able to advise you on the most appropriate system that best meets your needs Maximum ARTICLE Electronic Maximum Phasesupply
52. to the connector CORRECT Installation Radius of the curve The radius of the curve of the piping network located externally or into chase must be done with 45 connectors that will guarantee as little force as possible of passing vacuumed air e g a 90 curve can be made in two different ways firstly with a male female and female female curve connector secondly with a female female curve connector a small piece of pipe and another female female curve connector The fewer curve connectors installed in the system the greater the speed of the vacuumed air and the better the final performance of the cen tralised vacuum system will be 450 CORRECT Installation Linear junction of the pipe The junction of the piping must be made with the appropriate double stop coupling connector the stop found in all the connectors with a SISTEM AIR label is the element that ensures the piping combines with the connector To ensure the piping fits perfecting with the connectors and there are no gaps inside the piping it is ESSENTIAL to cut it with the appropriate tool This will ensure an exact linear cut with no burr Perfect internal fit CORRECT Installation 97 rif 01 2008 ENG www sistemair it ec 98 INSTALLATION Notes on installation Direction of suction For the branching of more inlet valve points use the female female 45 derivation connectors or male female 45 derivation This connector is used bo
53. 0 5MB 3200 7MB 3200 9MB ARTICLE N remote wall panel remote table panel Quantity 1 piece ctu K remote table panel Quantity 1 piece _ LL LLLA wall panel il Quantity 1 piece Resistive divider with 4 inlets Quantity 1 piece 65 rif 01 2008 ENG www sistemair it INDUSTRIAL Dust Separators Blowing Power Units Range Peripherals of central units www sistemair it INDUSTRIES CINEMAS THEATRES MUSEUMS HOTELS RESIDENTIAL RETIREMENT HOMES LTO 3 EI LIN pen 114 INDUSTRIAL Without self cleaning LT 80 LT 160 With self cleaning LT 80 C A LT 160 C A RECOMMENDED INSTALLATION The dust separators are specifically designed for installation in small or large scale businesses industries It is essential to use them in conjun ction with an industrial motor They should be installed in service rooms that are closed and protected from extreme weather conditions dampness and temperature changes Avoid installation near heat sources or in areas with temperatures over 409 At the planning sta ge it is advisable to identify the best location for the separator with respect to the system leaving a reasonable amount of space for instal lation use and maintenance You should also bear in mind the positioning of the air dischar ge piping to the outside and the piping coming from the vacuum sys
54. 00 900 Measurement F mm 115 115 Measurement mm 670 Measurement M mm 115 115 Measurement P mm 550 550 Measurement R mm 120 Noise level of motor dB A N B Levels of nominal noise The levels can vary according to the speed of use environment where the central unit has been installed and the kind of installation 56 www sistemairit rif 01 2008 ENG Central vacuum unit Series TECNO Block Mini TECNO Block Maxi PROFESSIONAL SPARE PARTS TABLE Filter cartridge Quantity 1 piece Bags Quantity 20 pieces 63mm air vent silencer Quantity 1 piece gt Compressor for Ay 2 a lt lt self cleaning 2 Quantity 1 piece Electronic pressure switch for self cleaning Quantity 1 piece Electronic pressure switch for self cleaning Quantity 1 piece Electronic card ZY for self cleaning Quantity 1 piece Timer for self cleaning Quantity 1 piece rif 01 2008 ENG TECNO Block Mini ART MODEL 3115 1MB 3115 2MB ARTICLE 1610 1 110002 040002 040016 040020 ACCESSORIES TABLE Anthracite coloured remote wall panel Quantity 1 piece Aluminium coloured remote table panel Quantity 1 piece Anthracite oloured remote table panel Quantity 1 piece Remote control P wall panel Quantity 1 piece central vacuum systems TECNO Block Mini ARTICLE 57 www sistemair it
55. 105 rif 01 2008 ENG www sistemair it e INSTALLATION Installation materials SPECIAL GLUE FOR PVC PIPES ARTICLE DESCRIPTION PACKING pcs 9225 1 250 g of special glue with brush 9225 2 500 g of special glue with brush 9500 0 500 g of special glue without brush PRE WIRED CONDUIT 2 X 1 ARTICLE DESCRIPTION PACKING pcs 9016 7 1 K 2x1 mm 25 m pre wired conduit 9016 0 2x1 mm 50 m pre wired conduit 9016 1 2x1 mm 100 m pre wired conduit BALL VALVE FOR MANUAL DIVISION ARTICLE DESCRIPTION PACKING pcs 2050 0 50 ball valve for manual division 2050 1 63 ball valve for manual division 2050 2 9 80 ball valve for manual division Fire stop coupling ARTICLE DESCRIPTION PACKING pcs 1150 3 50 fire stop coupling 1163 2 0 63 fire stop coupling 1180 2 80 fire stop coupling 1 Screw cap for testing installation ARTICLE DESCRIPTION PACKING pcs 5050 5 Screw cap for testing domestic system installations ALLUMINIUM PIPE ARTICLE DESCRIPTION PACKING pcs 1850 0A Alluminium pipe alloy 6060 50 2 2 mm Starke 3 m Bars 1863 0A Alluminium pipe alloy 6060 63 2 2 mm Starke 3 m Bars 106 1S wwwsistemair it rif 01 2008 ENG Installation materials INSTALLATION central vacuum systems ZINC COATED STEEL INSTALLATION MATERIAL Rigid steel pip
56. 200TE Generation for 350 m 3115 0TS Central vacuum unit model TECNOSTAR with 2 motors 3115 1MB Central vacuum unit TECNOBLOCK MINI QE 1 5kW 220 240 Volt 3115 1TA Central vacuum unit model SA400TA Generation for 450 m 3115 1TE Central vacuum unit model SA400TE Generation for 450 3115 2MB TECNOBLOCK MINI QE 1 5 kW 220 240 Volt vacuum unit with self cleaning 3200 0 Dust separator LT 80 3200 0A Dust separator LT 80 with self cleaning 3200 0MB Central vacuum unit TECNOBLOCK 2 2kW 380 Volt 3200 1MB Central vacuum unit TECNOBLOCK 2 2 kW 220 240 Volt 3200 2MB Central vacuum unit TECNOBLOCK 2 2 kW QE 220 240 Volt with self cleaning 3200 3MB Central vacuum unit TECNOBLOCK 2 2 kW 380 Volt with self cleaning 3200 4MB Central vacuum unit TECNOBLOCK 2 2 kW 380 Volt 3200 5MB Central vacuum unit TECNOBLOCK 2 2 kW 380 Volt with self cleaning 3200 6MB Central vacuum unit TECNOBLOCK 4 kW 380 Volt www sistemair it Catalogue PAGE 149 149 150 153 148 150 148 148 148 148 148 150 104 104 107 106 104 106 107 104 106 106 106 106 104 104 104 104 104 ARTICLE 3200 7MB 3200 8MB 3200 9MB 3202 1 3202 1A 3301 0 3301 1 3301 10 33012 3301 3 33014 3301 5 3301 6 3301 7 35013 4001 0 4010 0 4010 1 4050 0 4050 0F 4050 1 4063 0 4063 0F 4063 1 4080 0 4080 1 4100 0 4163 0 4163 1 4200 0 4200 2 4200 3 4200 6 4200 7 4300 0 5050 0 5050 1 5050 2 5050 4 5050 5 5063 4 6050 0F 6063 1 6063 3 7030 0 7030 01
57. 30 Measurement G air inlet o mm 60 80 80 60 60 80 100 Measurement H air outlet g mm 60 80 80 60 60 80 100 Measurement L mm 580 580 750 580 580 750 750 Measurement M mm 20 60 50 20 20 50 80 Noise level dB A 68 85 N B Levels of nominal noise www sistemair it The levels can vary according to the speed of use environment where the central unit has been installed and the kind of installation rif 01 2008 ENG Dust Separators Blowing Power Units Range Peripherals of central units INDUSTRIAL 54 central vacuum Systems SPARE PARTS TABLE Blowing power units 0600050 0600060 0600080 060005QE 060006QE 060008QE 060010QE Motor start up board Quantity 1 piece ACCESSORIES TABLE Blowing power units ART 0600050 0600060 0600080 060005QE 0600060 0600080 060010QE ARTICLE AN nthracite coloured 4200 0 SS remote wall panel XS Quantity 1 piece D 1 Anthracite coloured remote table panel Quantity 1 piece gt Selection and call board a for start up of Max 2 motors Quantity 1 piece gt Selection and call board 4 for start up of Max 3 motors Quantity 1 piece 29772 Selection and call board 3301 10 4 for start up of Max 8 motors Quantity 1 piece Control board to regulate speed max 1 motor Quantity 1 piece Control board to regulate speed max 2 motors Quantity 1 piece
58. 32 0505 7032 4 7033 0 7033 1 70552 0555 70337 7033 8 7034 0 7034 1 7034 2 7034 3 7035 0 7036 0 7037 1 7037 18 7037 2 7037 4 7037 4 70377 7038 0M 7038 1 7038 2 7039 0 7039 1 7039 21 7039 22 7040 0 7040 1 7040 2 7041 0 7041 1 7041 2 7041 3 7041 4 7041 5 7041 6 7042 0 7043 0 7044 0 7045 0 7046 0 7047 0 7047 1 7047 2 7047 3 7047 4 7048 0 7049 0 7100 0 7100 1 7100 2 8080 1 8080 3 8200 0 8200 1 8220 0 8300 0 On Off Cleaning accessory kit mod STANDARD 7 m hose Cleaning accessory kit mod STANDARD 9 m hose On Off Cleaning accessory kit mod STANDARD 9 m hose Accessory kit for oven Cleaning accessory kit mod BASIC with 7 m pipe Liquid separator with accessories Brush for liquids with rubber spatulas 30 cm Brush for pipes and balks Upholstery beater brush Ash separator in metal Brush for liquids 40 Carpet beater brush Carpet beater brush with 12 V battery 12 V battery for carpet beater brush Battery charger for carpet beater brush Felt head for wooden flooring Dual purpose brush Hose sock 7 m Flexible Hose by measure 18 m 32 Flexible hose by measure 10 m 40 Hose with ON OFF switch 9 m Hose sock 10 Hose with ON OFF switch 7 m Tube by measure 7 m 32 Wall end with metal ring hose end handle 40 Wall end swivel 40 Chrome metal end handle with pressure switch 32 Plastic end handle with pressure switch Upper elbow chrome handle 40
59. 32 FLEXIBLE 5 central vacuum systems ARTICLE 1455 0A 1455 0B 1455 0M 1455 0N DESCRPTION COLOUR PACKING pcs FLOOR INLET VALVE WITH MICRO SWITCH FLOOR INLET VALVE FOR 40 FLEXIBLE HOSE ARTICLE 1455 2A 1455 2B 1455 2M 1455 2N DESCRPTION COLOUR PACKING pcs FLOOR INLET VALVE WITH MICRO SWITCH STEEL KEY FOR PROTECTED INLET VALVES ARTICLE DESCRPTION PACKING pcs STEEL KEY FOR PROTECTED INLET VALVE STEEL KEY FOR PROTECTED INLET VALVE 127 www sistemair it MOUNT PLATES AND INLET VALVES Special inlet valves VALPAN INLET VALVES The SISTEM AIR vacpan inlet valves can be installed in the skirting board of the kitchen at home see design below The system can be turned on and off with a pedal po sitioned on the front of the opening Thanks to the mounting plate art 1450 16 it is possible to insert vacpan inlet valves also in the wall N B The vacpan inlet valves are fitted with an electric contact to control the central unit VACPAN INLET VALVES COLOUR White VACPAN INLET a Black 1 VALVE Silver ARTICLE DESCRIPTION PACKING PCS MOUNTING PLATE FOR VACPAN INLET VALVE ARTICLE DESCRIPTION PACKING PCS STEEL MOUNTING PALTE uo ag
60. 4 A 4 Wee Gd E G Ku O tq t CT Q I ua GGG aa KC Ka J g Si Gp NS 5 6 AS Q t Pipe network 32 www sistemairit rif 01 2008 ENG Sistem CUBE central vacuum unit DOMESTIC central vacuum Systems TECHNICAL SPECIFICATIONS The central vacuum unit Sistem CUBE complies with the standards provided for BM sm by current regulations and EU directives Furthermore it provides functionality rationalization of spaces power and easiness of use 17 14 The main technical specifications can be summarized as follows qs frame and support structure made of PP ABS plastic EE 5 litre dust bag Motor unit with direct cooling motor Heat safety probe to protect the engine group with automatic shut down and restart Electronic control card with protection fuse Vacuum power sockets with 12 V voltage Safety filter cartridge washable in water Designed for systems with 40 mm diameter piping System kits available separately with 1 2 or 3 sockets w Template available for air inlet outlet that can adjusted at 360 nen i Power supply and pre cabled micro line in the template with specific female connectors 16 Sistem Cube central unit complete with male connectors and easy hooking to the template 1 Cover 2 Dust bag 3 Machine body 4 Main switch 5 Filter sec
61. 4 computer RECOMMENDED INSTALLATION The central units are fitted with a connection for an air vent This is essential for sendino the microscopic dust particles that the filter cartridge cannot contain outside These central units can be fitted in plant rooms under the stairs cupboards etc The IP44 insulation level allow for installation in the open air such as on balconies or in particularly damp environments At the planning stage it is advisable to identify the best location for the central unit with respect tothe system leaving a reasonable amount of space for installation use and maintenance Speedy and accurate positioning of the central unit with respect to the piping network can be done using the positioning template provided In the event of a system on several floors it should be installed on the bottom floor www sistemair it Tecno Evolution without built in 1 year WARRANTY The central units in the TECNO Evolution Generation and TECNO Activa Gene ration series are used for domestic installations and residential systems with the following characteristics area to be cleaned between 30 and 450 m piping network with 50 mm diameter pipe 220 240 V ac single phase power discharge of filtered air outside suitable for one user at a time PARTICULAR CHARACTERISTICS OF THE PRODUCT Thanks to the IP44 electric insulation level the central units can be installed in areas subject to damp
62. 4 104 104 104 104 104 104 15 75 75 138 189 138 119 106 106 140 150 150 135 135 136 139 136 136 136 135 ARTICLE 3112 1TA 3112 3113 1 3113 1TE 3115 1TA 3115 0 5 7039 0 7040 1 7030 0 7032 4 7031 0 7031 2 7032 0 7032 2 7042 0 1612 5 7045 0 7047 4 4050 0F 4063 0F 7036 0 1614 3 16142 7047 3 7043 0 5202 3202 1A 3200 0 3200 0A 3050 1F 3063 1F 3050 0F 3063 0F 3301 6 3301 0 3301 10 1612 8 1612 10 3301 9 3301 1 3301 7 1612 4 1612 9 5050 4 5063 4 5050 0 5050 2 1450 9 1450 8 1456 3 7035 0 1610 0 1610 2 1610 1 1610 15 1610 7 1610 9 1610 4 1610 5 1150 3 1116352 DESCRIPTION Central vacuum unit model SA100TA Generation for 250 m Central vacuum unit model SA100TE Generation for 250 m Central vacuum unit model SA200TA Generation for 350 m Central vacuum unit model SA200TE Generation for 350 Central vacuum unit model SA400 TA Generation for 450 m Central vacuum unit model SA400TE Generation for 450 Central vacuum unit model TECNOSTAR with 2 motors Chrome metal end handle with pressure switch 0 32 Chrome telescopic extension 32 Cleaning accessory kit mod MINI Cleaning accessory kit mod BASIC with 7 m pipe Cleaning accessory kit mod ELITE Cleaning accessory kit mod ELITE 9 m hose Cleaning accessory kit mod STANDARD Cleaning accessory kit mod STANDARD 9 m hose Clothes brush with bristles Computer circuit
63. 455 0M 1455 0N 1455 2A 1455 2B 1455 2M 1455 2N 1456 1 1456 3 DESCRIPTION 2 metal silencer 3 metal silencer 4 metal silencer silencer in PVC 50 2 silencer in PVC 63 2 check valve for motor connection 4 check valve for motor connection 3 check valve for motor connection 220 240 V compressor for self cleaning Solenoid valve for self cleaning system Timer for self cleaning Rotating nozzle for dust separator LT 160 with self cleaning system 2 2 kW blowing power unit with 380 Volt control panel 2 2 kW blowing power unit with 380 Volt electronic board 4 kW blowing power unit with 380 Volt control panel 4 kW blowing power unit with 380 Volt with electronic board 5 5 kW blowing power unit with 380 Volt control panel 5 5 kW blowing power unit with 380 Volt electronic board 7 5 kW blowing power unit with 380 Volt electronic board Inspection screw cap in PVC 100 Pipe adaptor in PVC 80 100 Stop coupling PVC 100 Stop coupling PVC 50 Junction group steel pipe 50 mm Fire stop coupling 50 Stop coupling PVC 63 Junction group steel pipe 60 mm Fire stop coupling 63 Stop coupling PVC 80 Fire stop coupling 80 Steel key for protected Ave Living inlet valves Steel key for floor inlet valves Rectangular mounting plate 90 elbow connector with plaster guard Rectangular monting plate 2 elbow connector Rectangular mounting plate straight connector with plaster guard White finishing frame for squar
64. Box wall box Jolly Set for side discharge EXTERNAL INSTALLATION ARTICLE DESCRIPTION 1 1 8710 0 Jolly module Jolly Contact module Jolly Box external box rif 01 2008 ENG DOMESTIC central vacuum systems Art 8510 0 Discharge column with soundproof sponge JOLLY Box p Art 8511 0 Sa d Art 8510 1 Side discharge CLI can be rotated at 360 Art 8500 1 Air discharge in other environment External box Option e HE lt Option B A5 KR AAEHEHAH Air discharge in the same environment m mu mu LI E r wm p www sistemair it DOMESTIC JOLLY SYSTEM ELECTRIC CONNECTION N NE 220 240V Nm Classe 11 PERFORMANCE GRAPH Vacuum JOLLY mmH20 JOLLY CONTACT 100 150 200 250 300 Air flow m3 h 46 J www sistemairit rif 01 2008 ENG JOLLY SYSTEM DOMESTIC central vacuum Systems TECHNICAL SPECIFICATIONS ABS plastic external frame that can be painted Structure in propylene plastic Dust bag container for faster more hygienic maintenance Dust bag can hold 3 litres Warning light for replacement of full bag Single phase electric brush motor Heat safety probe to protect the engine group with automatic shut down a
65. Built in computer to control the maintenance cycles with signals for emptying the dust collector bin cleaning the filter cartridge and motor maintenance Set for the connection of a remote auxiliary maintenance warning signal op tional Possibility of controlling two separate micro lines Turbo function for more powerful vacuuming with just one activated micro line N B If a fuse has to be replaced make sure you use the correct amperage and that it is a SB fuse motor Stick rigorously to IEC and national power supply regulations during installation rif 01 2008 ENG DOMESTIC i central vacuum systems Cover Heat safety probes Computer maintenance Dust container open Close handle Filter cartridge Handle Base Dust container Wheels Soundproof dome Motor body Air vent Soundproof sponge Dust inlet Control panel Main switch Dust separator compartment Conveyor cone Bag string Dust bag 25 www sistemair it ws i DOMESTIC FITTING THE CENTRAL UNIT The central unit does not need any special mounting Ho wever you will have to check that the selected area for installation has the following minimum requirements in order for it to be correctly and safely positioned a perfectly flat horizontal solid resting surface the surfaces are not subject to vibrations Furthermore there should be no incongruities that would ma
66. DOMESTIC PROFESSIONAL INDUSTRIAL JOLLY SYSTEM Catalogue Central vacuum systems A lo GUAR Aik CENTRAL VACUUM CENTRAL VACUUM SYSTEMS ING a world of well be gt Lu u 2 gt lt gt lt oc Lu afi T cD zt Hygiene comfort and total simplicity 1 Central vacuum cleaner 2 Pipes made of PVC 3 Silencer 4 Suction inlet W ololtt Alk CENTRAL VACUUM SYSTEMS ENTRALISED VACUUM 11 CENTRAL VACUUM SYSTEMS Sistem Air is Europe s leading Manufacturer of complete central vacuum systems Its products stand out for their quality innovation and design It is deeply involved in the training of its distributors and installers for years Its objective is to continually upgrade the quality level of both the products themselves and the entire system Sistem Air is committed in providing its customers with constant research amp design striving to increase its sales a constant challenge to its competitors Thorough knowledge of the foreign market has created an interactive communication channel which results in high quality user friendly products continuous evolution CENIRALISED VACUUM CLEANERS UA olo HIR CENTRAL VACUUM SYSTEMS research design and oroduct cevelopment The design department produces top quality results achieving an excellent quality to price r
67. DS OF SELECTION MODEL ARTICLE Speed can be set Speed can be modulated Speed converter Electronic card for speed manually electronically modulation TECNO 3115 1 MB Block Mini 3115 2 MB Legende Performance graph B Number of speeds that can be set Art 3115 1MB 3115 2MB eg MM 2speeds can be set Vacuum al Eves mbar 450 22 400 350 300 4 1 Speed1 250 Speed 2 200 150 100 50 0 m3 h 100 200 300 400 500 Air flow 54 MN www sistemairit rif 01 2008 ENG Central vacuum unit Series TECNO Block Mini TECNO Block Maxi PROFESSIONAL i central vacuum systems 15 FE 16 17 TECHNICAL SPECIFICATIONS The main technical characteristics of the central units in the BLOCK MINI range can be listed as follows Cylindrical frame of epoxy powder painted metal Base and supports of epoxy powder painted metal Metal dust container holds 45 litres with wheels for movement Bag and bag string in the dust collector to rapidly and hygienically dispose of vacuumed matter The option of connecting to the piping both from the right and left Motor pump unit with professional CE regulated motor IP55 insulation category F Pump for emptying from side channel covered in light alloy with top perfor mance It is also maintenance free Motor n
68. E ARTICLE HOSE MM START UP CONTACT yy S AG 2 x 760 760 SYSTEM UNWINDING ATTACHMENT LENGTH MM M PACKING PIECES 032 YES 050 www sistemair it KITS AND ACCESSORIES 141 EQUIPMENT AND SYSTEMS oct d 1 an gen 2 kas _ i p 1 ki F a _ to improve the quality of work www sistemair it EGU rompen SIS EQUIPMENT AND SYSTEMS 144 www sistemair it EQUIPMENT The SISTEM AIR installation equipment simplifies and improves the quality of work the template allows you to place the piping in the correct position where the central vacuum unit will be installed without wasting time and with consi derable space reduction The pipe cutter allows you to cut the pipes with precision and obtain a perfect coupling with the connectors The screw cap for depression testing is used to hermetically seal the mounting plates in order to test the hold of the piping network before being buried into the floor with the vacuum gauge accessory you can read the pressure loss of a system in proportion to the vacuum of the central vacuum unit CONNECTION TEMPLATE FOR TECNO SERIES OF CENTRAL UNITS ARTCLE COLOUR MATERIAL PACKING pcs ZINC PLATED 2
69. E PRODUCT DESCRIPTION Quantity 3202 1 160 litre dust separator 4 445907 380 V 5 5 kW blowing power unit complete with control panel 3 metal silencer 0110003 Q 3 retention valve for the coupling of more than one motor Control panel for cascade start up of 2 motors ARTICLE PRODUCT DESCRIPTION Quantity 3202 1A 160 litre dust separator with self cleaning filter 1 4 545977 380V 5 5 kW electronic blowing power unit complete with control panel 2 3 metal silencer 2 0110003 Q 3 retention valve for the coupling of more than one motor 2 ARTICLE PRODUCT DESCRIPTION PAPAIN 160 litre dust separator with self cleaning filter 444445977 380 V 4 kW electronic blowing power unit complete with control panel Control panel for cascade start up of 3 motors 3 metal silencer 3 0110003 3 retention valve for the coupling of more than one motor 3 1 92 m J www istemairit rif 01 2008 ENG EXTENSION OF THE SYSTEM adaptability of planning realizatiol n Th possibility of connecting more motors and t division of the piping system into more lines allows the use of the system by as many operators as wished and also allows any number of inlets The aim is as usual to find the best compromise between performance and comfort DEPOSITO 26 50 d 758 o d Tati nup CUCINA k BISTROT 60 POSTI A SED
70. ERE 31 A rif 01 2008 ENG w wwwsistemairit INSTALLATION perfect fit of all components www sistemair it Ld Wi m per a A mmi Notes on installation Installation kits 4 N A L DAVAN LIE Fa r SEE FI M h TM i INSTALLATION Notes on installation NOTES ON INSTALLATION The SISTEM AIR piping is made up of antistatic self extinguishing PVC built to guarantee a perfect combination between piping and connections In parti cular the piping is Self extinguishing antistatic calibrated with thickness of between 2 2 mm for 50 mm diameter and 3 mm for 63 80 100 mm dia meter All connections of the piping network are glued together with special self adhesive cold glue Its particular technical characteristics ensure that the glued parts stick perfectly The correct setting and installation of the piping network ensures that the sy stem works properly and this is why it is undoubtedly considered the most im portant stage for obtaining optimum running of the centralised vacuum system We advise all operators to stick rigidly to the advice provided in order to simplify the operations for compiling the piping networ
71. H w DUAL PURPOSE BRUSH FOR FLOORS CARPETS BATTERY CHARGER FOR CARPET BEATER BRUSH FELT HEAD FOR WOODEN FLOORING UPHOLSTERY BEATER BRUSH CARPET BEATER BRUSH CLOTHES BRUSH WITH BRISTLES i id Packing Packing Packing Packing Packing 135 rif 01 2008 ENG www sistemair it KITS AND ACCESSORIES Cleaning accessories DUST BRUSH WITH BRISTLES BRUSH FOR ANIMALS AYER Black Plastic 7049 0 BRUSH FOR MATTRESSES AND UPHOLSTERY 30 CM BRUSH FOR LIQUIDS WITH RUBBER SPATULAS CREVICE TOOL RADIATOR BRUSH 7045 0 Plastic BRUSH FOR PIPES AND BALKS 7MON OFF ELECTRIC HOSE Article Material Article Colour Material Packing lt lt X m 7033 2 Plastic 7037 4E Silver Plastic Pcs 1 9 m on off electric hose Article Colour Material Packing SA Y 136 SS www sistemair it rif 01 2008 ENG Cleaning accessories KITS AND ACCESSORIES FITTING PIPE INLET WITH METAL RING HOSE 7 m by measur qu Article Colour Material Article Colour Material KANN LU G7 SAN Ne IM n 7037 7 Silber Plastic 7038 0M Black Plastic HANDLE WITH AIR REGULATION HOSE BY MEASURE Article Colour Material Article Colour Material SS DPN AD Yi NN 271 7039 1 Black Plastic 22 Silver Plastic SCHEATH FOR HOSE 7 m HANDLE WITH AIR REG
72. ION Stop coupling PVC 63 Stop coupling PVC 80 Substitute circuit board for Tecno Block unit Table remote control panel aluminium colour Table remote control panel anthracite colour TECNOBLOCK MINI QE 1 5 kW 220 240 Volt vacuum unit with self cleaning Template for TA TE central vacuum units Timer for self cleaning Tube by measure 7 32 Universal bag and bag tightener housing line pz 10 Upholstery beater brush Upper elbow chrome handle 0 40 Vacpan aluminium color Vacpan black colour Vacpan white colour Vacuum gauge for system testing Wall end swivel 40 Wall end with metal ring Wall remote control panel Wall remote control panel for central vacuum units Wall remote control panel with box White finishing frame for square inlet valve pack of 5 pieces Wolly 150 central unit Wolly 150 central unit rif 01 2008 ENG Catalogue PAGE 105 105 152 111 111 53 144 151 137 148 135 139 128 128 128 145 139 137 110 111 110 125 37 27 ARTICLE 11001 11002 11003 110001 110002 0110001 0110002 0110003 040002 040016 040020 040023 0600050 0600050 0600060 0600060 0600080 0600080 0600100 1010 1 1010 3 1110 1 1150 1 1150 1F 1150 3 1163 1 116516 1163 2 1180 1 1180 2 1400 0 1400 1 1450 0 1450 0E 1450 1 1450 10 1450 11 1450 12 1450 13 1450 1E 1450 2 1450 2E 1450 3 1450 3E 1450 4B 1450 4E 1450 5B 1450 5E 1450 8 1450 9 1450 16 1450 18 1455 0A 1455 0B 1
73. L central vacuum systems CENTRAL UNIT SELECTION TABLE You can choose from a vast range of central unit models They can be used by a minimum of 1 operator and a maximum of 3 simultaneously taking into consideration the surface area to be cleaned as varying between 500 and 1200 m Furthermore it is possible to decide whether to have a central unit with self Cleaning filter or not MODEL ARTICLE Maximum Central unit wih Motor power Supply stages Maximum air Filtering Dust container number of self cleaning kW Volt ac flow m h surfaces cm capacity litres operators 3200 0MB 3 380 300 24000 3200 3MB 3 380 300 24000 3200 1MB 220 240 210 340 24000 3200 2MB 220 240 210 340 24000 TECNO block 171 3 380 210 360 24000 Maxi 3200 5MB 210 360 24000 3200 6MB 250 450 24000 3200 7MB 3 380 250 450 24000 3200 8MB 3 380 250 530 24000 3200 9MB 3 380 250 530 24000 ELECTRONIC SPEED CONVERTER ELECTRONIC BOARD Electronic board for the automatic modulation of speed and performance Electronic converter Control panel with up to 3 speeds depending on which model LLLLLEEEELELELE EEEEELEEEETETIT NB can be used with systems adapted for their use and fitted with resistive dividers art 3301 4 The central vacuum units of the Tecno Block Maxi series offer a high
74. M CUBE Filter cartridge in polyester for TECNOSTAR units Filter cartridge in polyester for Wolly Filter cartridge in polyester LT 160 Filter cartridge in polyester for MINI TA TE models Fire stop coupling 50 Fire stop coupling 63 rif 01 2008 ENG Catalogue PAGE 15 15 15 15 15 15 23 137 137 132 132 133 133 133 133 135 148 136 139 107 107 135 153 150 139 136 69 69 69 69 107 107 107 107 83 83 83 150 150 151 152 83 149 150 105 105 105 105 120 120 126 135 148 152 151 150 150 150 148 148 106 106 ARTICLE DESCRIPTION 1180 2 Fire stop coupling 80 70372 Flexible hose by measure 10 m 40 7037 18 Flexible Hose by measure 18 0 32 7047 0 Floor brush 37 cm 70472 Floor brush 48 cm 40 1455 0N Floor inlet valve black colour with micro 32 mm 1455 2N Floor inlet valve black colour with micro 40 mm 1455 0M Floor inlet valve brown colour with micro 32 mm 1455 2M Floor inlet valve brown colour with micro 40 mm 1455 0A Floor inlet valve grey colour with micro 32 mm 1455 2A Floor inlet valve grey colour with micro 40 mm 1455 0B Floor inlet valve white colour with micro 32 mm 145528 Floor inlet valve white colour with micro 40 mm 1450 3E Floor mounting plate straight union 1450 2 Floor mounting plate aluminium 90 elbow 1450 2E 1450 3 Floor mounting plate aluminium straight union 1542 0 Generation inlet mod ABB Chiara 1541 0 Generation inlet mo
75. R PACKING pcs 1450 10 white FINISHING FRAME 1450 11 EXPLANATORY DRAWING NOTE Any plaster defects around the square mounting plate can be resolved by inserting the fini shing frame between the mounting plate and the inlet valve 125 rif 1 2008 ENG www sistemair it s MOUNT PLATES AND INLET VALVES Special inlet valves SPECIAL INLET VALVES The SISTEM AIR inlet valves meet all kinds of system needs in businesses and in dustries The insulation level for micro switches fitted both on the floor sockets and external industrial ones is IP65 N B The industrial external inlet valves are fitted with an attachment both for 50 mm rigid piping and for 63 mm piping using the double stop coupling parts no 1163 1 as a junction EXTERNAL INLET VALVE FOR 32 FLEXIBLE HOSE 50 PVC PIPES ARTICLE DESCRIPTION COLOUR PACKING pcs External domestic inlet valve INDUSTRIAL INLET VALVE FOR 32 FLEXIBLE HOSE ARTICLE DESCRIPTION PACKING pcs INDUSTRIAL EXTERNAL INLET VALVE WITH MICROSWITCH INDUSTRIAL INLET VALVE FOR 40 FLEXIBLE HOSE ARTICLE DESCRIPTION PACKING pcs INDUSTRIAL EXTERNAL INLET VALVE WITH MICRO SWITCH 126 www sistemairit rif 01 2008 ENG Special inlet valves la rif 01 2008 ENG MOUNT PLATES AND INLET VALVES SPECIAL INLET VALVES FLOOR VALVE FOR 0
76. RATION INLET VALVE VIMAR IDEA PLANA GENERATION INLET VALVE VIMAR IDEA PLANA GENERATION PLANA SILVER VIMAR EIKON GENERATION INLET VALVE VIMAR NEXT GENERATION INLET VALVE www sistemair it 123 a MOUNT PLATES AND INLET VALVES Inlet valves GEWISS SERIES OF GENERATION INLET VALVES DESCRIPTION PACKING PIECES ARTICLE GEWISS PLAYBUS GENERATION INLET VALVE GEWISS CHORUS WHITE GENERATION INLET VALVE GEWISS CHORUS BLACK GENERATION INLET VALVE AVE SERIES OF GENERATION INLET VALVES ARTICLE DESCRIPTION PACKING PIECES AVE NOIR GENERATION INLET VALVE AVE BLANC GENERATION INLET VALVE AVE RAL GENERATION INLET VALVE AVE BANQUISE WHITE GENERATION INLET VALVE LEGRAND SERIES OF GENERATION INLET VALVES ARTICLE DESCRIPTION PACKING PIECES LEGRAND VELA BLACK GENERATION INLET VALVE 1551 3 LEGRAND VELA WHITE GENERATION INLET VALVE ABB SERIES OF GENERATION INLET VALVES ARTICLE DESCRIPTION PACKING PIECES ABB ELOS GENERATION INLET VALVE 1542 0 ABB CHIARA GENERATION INLET VALVE 124 uwu istemair it rif 01 2008 ENG Inlet valves MOUNT PLATES AND INLET VALVES central vacuum systems INLET VALVES INLET VALVES FOR SQUARE MOUNTING PLATE ART 1450 4B AND ART 1450 5B ARTICLE DESCRIPTION COLOUR PACKING pcs 1464 0B wnit 1464 2B Silver FINISHING FRAME FOR SQUARE SOCKETS ARTICLE DESCRIPTION COLOU
77. T T T T T T T T 0 50 100 150 200 250 300 350 400 Air Flow m3 h Electric layout 2 2 Motor with 2 Micro line Micro line 1 Floor M2 Micro line Ground floor rif 01 2008 ENG Central vacuum Series TECNO Star TECHNICAL SPECIFICATIONS The central vacuum units of the TECNO Star series have been designed and bu ilt in compliance with current legislation and EU directives without however neglecting the fundamental elements such as operational ability power and practicality of use The main technical characteristics can be listed as follows Cylindrical frame by epoxy powder painted metal Base and supports by epoxy powder painted metal Metal dust container holds 60 litres with wheels for movement Bag and string for dust collector to rapidly and hygienically dispose of the vacuumed matter Soundproof motor compartment Noise level of central unit 64 dB A running on one motor 69 dB A running on two motors Possibility of connecting piping either from right or left Rotating motor body made up of a single phase electric brush motor Heat safety probe to protect the engine group with automatic shut down and restart Double protection electric control board with fuse block switches both on the main and secondary circuit Vacuum power sockets with 12 V dc voltage BIA USG certified polystyrene filter cartridge washable with water filtering surfaces 16600 cm
78. TAR central units Motor for Media Plus TA TE Generation Motor for SA050 0TA Motor for MEDIA PLUS central unit Motor for MIni Media SA50 TA TE Generation Motor for SA100 TA TE Generation Motor for SA100TA TE Motor for SA200 TA TE Generation Motor for SA200TA Motor for SA400 TA TE Generation Motor for SA400TA central unit Motor for Sistem Cube Motor for TECNO STAR Motor for Wolly On Off Cleaning accessory kit mod ELITE 7 m hose On Off Cleaning accessory kit mod ELITE 9 m hose On Off Cleaning accessory kit mod STANDARD 7 m hose On Off Cleaning accessory kit mod STANDARD 9 m hose Pair of 32 extension chrome fittings Pipe adaptor in PVC 80 100 Pipe adaptor 50 63 www sistemair it Catalogue PAGE 108 35 108 35 108 108 108 108 125 49 44 44 44 44 44 151 151 44 151 44 44 151 151 151 43 43 107 107 140 141 141 139 138 149 149 149 148 149 149 148 150 150 148 149 149 148 148 149 148 149 148 149 150 150 150 134 134 134 134 137 105 105 155 Ss 156 ALPHABETIC CONTENTS ARTICLE DESCRIPTION 7039 1 33013 9016 1 9016 0 9016 7 2050 3 2050 0 2050 1 2050 2 5050 1 6063 1 8080 1 1850 0 1863 0 1880 0 4100 0 4163 0 1810 0 4010 1 4050 1 4063 1 4080 1 4010 0 4050 0 4063 0 4080 0 7046 0 1450 0E 1450 0 1450 1 1450 1E 3301 4 040023 1450 13 1450 12 5050 5 110001 110002 7100 0 8300 0 040016 4163 1 9500 0 8205 92252 92253 3301 5
79. TEHT an II meet 3 11 L DOMESTIC Serie TECNO Star Central vacuum 22 Up to 450 m2 2 Operators tt RECOMMENDED INSTALLATION The central units from the TECNO Star range are fitted with an air vent connection which is essen tial for expelling the microscopic dust that the fil ter cartridge cannot contain outside It should be installed in plant rooms garages and protected from extreme weather conditions and excessive temperature changes You should choose areas at some distance from heat sources such as heaters or central heating N B IP20 insulation level for central units At the planning stage it is advisable to identify the best location for the central unit with respect to the system leaving a reasonable amount of space for installation use maintenan ce and a correct re circulation of air around the central unit Furthermore its specific building cha racteristics allow you to connect the central units to the system with piping coming from either the right or left In the event of a system on several floors it should be installed on the bottom floor www sistemair it INSTALLATION AREA The TECNO Star central vacuum unit is recommended for residential and has the following characteristics recommended surface area to be cleaned between 300 and 450 m vacuum
80. TION AREA The TECNO Block Mini central vacuum unit is used for residential homes and for the small business sector It is specifically indicated for all the system cases with extended piping that have the following characteristics area to be cleaned between 350 and 600 m vacuum network built with 50 mm and 63 mm diameter pipes and inlet con nector to the central unit 220 240 V ac single phase power air discharge to the outside suitable for systems being used by a single operator PARTICULAR CHARACTERISTICS OF THE PRODUCT the central vacuum unit performs like a professional apparatus while still being compact in size the dust bag holds up to 45 litres it is an industrial top performance motor with a light alloy blower with side channels and is maintenance free performance is managed using the electronic system on the central unit capable of handling and controlling the vacuum power according to actual needs it is fitted with a self cleaning system only on the 3115 2MB model for the controlled activation of the filter cartridge maintenance the motor has a start up system for the reduction of peak absorption the energy consumption is very low whatever the working condition with re gards to performance MAIN CHARACTERISTICS Central vacuum unit with metal support base that highlights its sturdiness Dust container fitted with wheels and handles to make emptying easier The option of conne
81. ULATION Colour Material Packing 7037 1 Jeans Wool Pcs 1 CHROMIUM PLATED TUBES SHEATH FOR HOSE 7040 0 Steel HOSE FITTING EXTENSION Colour Material Packing Article Material Chromium Colour Material 7037 4 Jeans TELESCOPIC EXTENSION CHROMIUM PLATED 7048 0 Black Plastic rif 01 2008 ENG www sistemair it i KITS AND ACCESSORIES Cleaning accessories ACCESSORIES HOLDER FOR MINI 4 PIECES ACCESSORIES HOLDER 10 PIECES 7041 1 Colour Material Packing Article Colour Material Packing Plastic Pieces 1 Anthracite Plastic Pieces 1 80 110 80 ACCESSORIES TROLLEY Article Colour Material Packing Pieces 1 JI C V e m _______ a Emi IE 1144 11 He 138 wwwsistemairit rif 01 2008 ENG Cleaning accessories 040 10 M FLEXIBLE HOSE 40 FLEXIBLE HOSE CONNECTOR HANDLE 40 FLEXIBLE HOSE WALL END SWIVEL 40 FLEXIBLE HOSE CHROME ELBOW HANDLE UPPER 40 FLEXIBLE HOSE CHROME ELBOW HANDLE LOWER Colour Material Packing 7039 22 Steel Pcs 1 E TZ S Gat 20880000 rif 01 2008 ENG KITS AND ACCESSORIES 40 40 DUST BRUSH WITH BRISTLES Colour Material Packing
82. Volt Ac Absorption number speed air flow kW A of operators converter m h 060005Q 060005QE 210 340 060006Q 460 060006QE 300 450 060008Q 590 060008QE 280 650 060010QE 280 970 Power reliability and working life are features common to every blowing motor of the Sistem Air industrial series 75 rif 01 2008 ENG www sistemair it CONNECTION TO THE PIPING NETWORK ELECTRONIC CONVERTER Vent grate You can set different speeds performance usage on the blowing motor unit Combined with the control panel for spe ed modulation Art 3301 5 not included but supplied on re Discharge pipe MM MEM quest the speed strength of blowing will automatically be Connection pipe proportioned on the basis of actual vacuuming needs optimi to dust separator sing performance and reducing power consumption Note available according to the models and can be used with micro line systems fitted with resistive dividers Parts no 3301 4 Silencer Speed modulation control panel N MN WU 4 Y Motor control panel Electronic converter WU SYSTEM THAT CAN MODULATED Total combination flexibility to find the best solution for your project Note in the case of solutions with more than one motor fit them with retention valves select from the technical data table and accessories table Control panel Retention valve
83. a Generation 3108 1TA MEDIA 3109 1TA MEDIA PLUS TA 3110 1TA SA 50 3112 1TA 5A 100 3113 1TA 3115 1TA SA 200 Quantity 1 piece 1610 5 1610 0 50 mm 2 air vent silencer Quantity 1 piece 110001 Motor body 1623 7 Quantity 1 piece 1623 8 1623 9 1623 10 1623 11 Motor brushes R 1611 10 SS Quantity 1 piece 1611 11 Electric board A for motor amp 9 Quantity 1 piece 1612 4 Electric board for E computer Quantity 1 piece ACCESSORIES TABLE Evolution Generation 3108 1TE 3109 1TE MEDIA 3110 1TE 3112 1TE 3113 1TE 3115 1TE 3107 1TA TECNO Activa Generation MEDIA 3108 1TA 3109 1TA MEDIA PLUS TA 3110 1 50 3112 1TA SA 100 3113 1TA 3115 1TA SA 200 SA400 Remote control wall panel Quantity 1 piece Bag and bag string Quantity 10 bags 10 bag strings rif 01 2008 ENG www sistemair it 19 L DOMESTIC Central vacuum Series TECNO Star TECNO turbo function maximum suction i 1 I 1 l m pe ui 1 tn LU a kom TUS www sistemair it UL j TECNOStar S
84. acteristics area to be cleaned between 500 and 1200 m piping network made with a pipe of between 50 and 63 mm in diameter and 63 mm inlet connector to the central unit 80 mm for the 3200 8 MB and 3200 9MB models single phase 220 240 V ac or three phase 380 V power depending on the mo dels air discharge to the outside use of the system simultaneously by 1 to 3 operators depending on the mo del PARTICULAR CHARACTERISTICS OF THE PRODUCT the monoblock central unit performs like a professional system itisan industrial top performance motor with blower light alloy side channels and it is maintenance free The self cleaning system for models fitted with the self cleaning filter auto matically reset the filtering capacity the motor has a start up system for the reduction of absorption peak except models 3200 0MB and 3200 3MB Furthermore it offers the possibility of personalising performance according to the vacuum strength required he energy consumption is very low considering its performance CHARACTERISTICS Central vacuum unit with metal support base that highlights its sturdiness Dust container fitted with wheels and handles to make emptying easier The motor starts with a reduction in acceleration at start up The machine has a section switch for the micro line to make maintenance easier rif 01 2008 ENG Central vacuum unit Series TECNO Block Mini TECNO Block PROFESSIONA
85. acuum mmH20 Connection of power cable Central vacuum Series Tecno Activa Tecno Evolution Connection of input activation signal ca ble 12 V dc Micro Line Connection of output cable for auxiliary maintenance warning signal contact normally open N O max 12V 0 10 A only for TA central units N B Use of this signal is optional MEDIA PLUS Generation 100 TE TA Generation 50 100 150 200 250 300 Air Flow m3 h 50 100 150 200 250 300 Air Flow m3 h rif 01 2008 ENG Central vacuum Series Tecno Activa Tecno Evolution TECHNICAL SPECIFICATIONS The central units of the TECNO Generation series are made from plastic poly propylene and ABS and are resistant to atmospheric polutants They have been designed and built in compliance with the strictest criteria imposed by current legislation and EU directives without however neglecting the fundamental ele ments such as operational ability power and capability of use The main technical characteristics can be listed as follows self supporting cylindrical polypropylene body protection and covering in Polypropylene and ABS Polypropylene dust collector with handles capacity depends on the model Soundproof motor compartment central unit noise level below 70 Option of connecting the piping from either the right or left Rotor motor body made up of a single
86. ag a l ee FOR VACPAN INLET VALVE 128 wwwsistemairit rif 01 2008 ENG Special inlet valves MOUNT PLATES AND INLET VALVES central vacuum systems EXPLANATORY DRAWING N S SA SN PERFORATION LAYOUT FOR FIXING THE SKIRTING BOARD SS SS 129 rif 01 2008 ENG www sistemair it KITS AND ACCESSORIES tota hygiene cleaning m www sistemair it Full accessory kits Single accessories Special separators Hose reels Ec Es RENE KITS AND ACCESSORIES Full kits Complete cleaning accessories kit 032 mm cleaning accessories kit for rectangular and square mounting plates Cleaning accessory kit suitable for rectangular and square inlet valves supplied in single packing ARTICLE ARTICLE PRA CLEANING ACCESSORIES KIT BASIS AENT CLEANING ACCESSORIES KIT MINI Description Article Q ty Description Qty Accessory holder 4 pieces 7041 1 EZ Wall end swivel connector 7038 0 gt S watya sasa 7037 7 k 7039 1 lt gt Wall end swivel connector 7038 0M ES Pair of chrome pipes 7040 0 Plastic elbow connector 7039 1 ES 30 cm floor brush 7047 1 Pair of plastic pipes 7040 2 a 22 30 cm flo
87. ain and secondary circuit The power of the motor should be selected according to the end user s requirements The dust collector is fitted with comfortable handles and can be used without a dust bag The TECNO range has 14 central vacuum unit models so that the product perfectly satisfy the different size requirements and surface areas to be cleaned rif 01 2008 ENG Central vacuum Series Tecno Activa Tecno Evolution DOMESTIC i central vacuum Systems CENTRAL UNIT SELECTION TABLE The central units can be used by a single operator The central vacuum units should be selected according to the surface area to be cleaned in order to ensure long life and best performance over time Once the size of the surface area has been established one can start applying certain selection criteria such as the computer maintenance warning cycle the capacity of the dust holders the filtering surface and the size of the central unit Maximum MODEL ARTICLE Maximal inlet Operators Maintenance Dust container Filtering surface Powersupply Motor power Air volume surface valves maximum computer capacity cm Volt ac kW m3 h simultaneous l MINI TE 3107 1TE 220 240 MINI TA 3107 1TA 220 240 MEDIATE 0 60 220 240 MEDIA 0 587 220 240 SA 050 220 240 SA 050 BERR 220 240 MEDIA PLUSTE 7 1 NO 15 6700 220 240 1 4 184 MEDIA PLUS TA MEPA kr 7 1
88. allation kit with 3 inlet valves 40 mm Installation kit with 3 square inlet valves Installation kit with 3 square inlet valves 40 mm Installation kit with 4 inlet valves Installation kit with 4 square inlet valves Installation kit with 5 inlet valves Installation kit with 5 square inlet valves lvory finishing frame for square inlet valve pack of 5 pieces Jolly basic set Jolly blind box cover Jolly box Jolly box extension Jolly cleaning accessories kit Jolly cleaning accessories kit with 12 m hose Jolly decorative frame in grained wood Jolly decorative frame in light carbon Jolly external box Jolly protection filter for motor washable Jolly set fittings for side discharge Jolly set grates for air discharge Jolly spare card Jolly spare dust bags pack of 5 Jolly spare motor Jolly vacuum unit Jolly vacuum unit contact Junction group steel pipe 50 mm Junction group steel pipe 60 mm Liquid separator with accessories Loose hose reel 32 Loose hose reel 40 Lower elbow chrome handle 0 40 Mini kit accessory holder for 4 pieces Motor brushes for MEDIA PLUS central units Motor brushes for 5 050 central units Motor brushes for SA100TE TA central units Motor brushes for SA200 400TE TA Generation Motor brushes for SA200TE TA central units Motor brushes for SA400 TE TA central units Motor brushes for SA50 100 Mini Med M PlusTE TA Generation Motor brushes for Sistem Cube Motor brushes for TECNO S
89. ange they refer to They should be purchased from authorised outlets N B The finishing plate are not supplied by Sistem Air Warning The square sockets already come with aesthetic finishing in two different colours and need the use of an appropriate cleaning accessory kit see section on cleaning accessories rif 01 2008 ENG Inlet valves and their usage MOUNT PLATES AND INLET VALVES central vacuum systems USAGE OF STANDARD FLEXIBLE HOSE The Sistem Air Generation inlet valves are fitted with a micro switch which acti vates when the hose has been inserted the central vacuum unit thus allowing you to clean The central vacuum unit will be deactivated when the flexible hose has been extracted USAGE OF ELECTRIC FLEXIBLE HOSE The Sistem Air Generation inlet valves are adequate for the use of flexible elec tric hoses The activation deactivation of the central vacuum is effected by the use of the micro switch ON OFF from the handle of the flexible hose 115 rif 01 2008 ENG www sistemair it MOUNT PLATES AND INLET VALVES Mounting plates MOUNTING PLATES FOR INLET VALVES PVC PIPING The standard rectangular mounting plates with elbow connector are suitable for all the inlet valves that accept the decorative plaques while the square mounting plates are suitable for the inlet valves already complete with aesthetic finishing in two different colours Each model has set notches for the pre wired c
90. aracteristics are very similar to the traditional vacuums but it also provides the user with most of the features of a central vacuum system such as versatility of use discharge of micro dust out side and vacuum power The ease with which it is mounted makes it perfect for installation even in exi sting buildings INSTALLATION AREA The Jolly system is used for installation in homes with the following specifications Surface area capacity to be cleaned in between 45 and 90 for each installed module depending on the layout of the area and how the side di scharge is set 9 meters flexible hose 220 240 V ac single phase power Discharge of air to the outside Use of each module by 1 operator simultaneously Possibility of installation in the centre of a room on inserts using the box pro vided with side discharge PARTICULAR CHARACTERISTICS OF THE PRODUCT The vacuum modules of the Jolly series offer the possibility of arranging the system by inserting the wall box and extension hose in the perimeter wall or in the inserts here is no need for hard piping under the floor The presence of a heat sensor to protect the motor guarantees automatic shut down and restart in the event of a malfunction Signal light when bag is full Motor protection fuse Easily replaced dust bag Visible panel with embossed finishing rough in order to be painted the same colour as the walls panel also available
91. atio considerable energy savings and a product range for all requirements Design and the wide of products represent the distinctive the Sistem Air brand ADI DESIGN 2002 TECHOPLUS Kri HETEM AT Vua 27010 GRAVELLONA LOMELLINA PW Contant Mu Piai Pee 0 il ammam kanon L lama Er 1007 252 E CEL NO 240 0 kani rim el dasi ip gu i aris icd Pee mir dll mme _______ LL Se namm eating Services MA lnc Ai XE ka NY 13045 2014 USA i informative material support for both users and installers The marketing tools provided by Sistem Air are a fundamental element for solid informa tion Thanks to the information provided more exacting decisions can be made the In VA ternet gives you fast access to our on line data our DVD offers a wide panorama on the products and systems whilst hard copy information is still the most proffered method gt p Please contact us for further information List of available items e General catalogue e Information DVD e Cost estimation software e List of specifications e Certification By SISTCO AIR
92. board for TECNO Activa central units Crevice tool Crevice tool 40 Derivation Pipe 45 Male Male Male 50 Derivation Pipe 45 Male Male Male 60 Dual purpose brush Dust bags for separator LT 160 pcs 20 Dust bags for separators LT80 and Tecno Block Mini Dust brush 48 cm 40 Dust brush with bristles Dust separator LT 160 Dust separator LT 160 with self cleaning Dust separator LT 80 Dust separator LT 80 with self cleaning Elbow pipe 45 Male Male 50 Elbow pipe 45 Male Male 60 Elbow pipe 90 Male Male 50 Elbow pipe 90 Male Male 63 Electronic board for 2 motor starter system Electronic board for 3 motor starter system Electronic board for 8 motor starter system Electronic board for computer Electronic board for computer Wolly soft start system Electronic card for automatic filter cleaning Electronic card for motors with circuit board Electronic card for self cleaning Electronic card for TE TA central units Electronic card for TECNO STAR spare parts Exhaust vent 50 Exhaust vent 63 Expansion joint 50 Expansion joint 63 Extension kit for square mounting plate Extension kit for universal mounting plate External industrial inlet valve with micro 40 mm Felt head for wooden flooring Filter cartridge for TE TA central units Filter cartridge in polyester for dust separator LT 80 Tecno Block Maxi Filter cartridge in polyester for TECNO BLOCK MINI Filter cartridge in polyester for SISTE
93. ced quickly and cleanly Another particularly interesting characteristic is that this new central unit is already provided with a complete cleaning accessory kit with 9 m hose with a single item code it will be possible to receive useful material to get the new central vacuum system ready for use rif 01 2008 ENG Sistem CUBE central vacuum unit DOMESTIC central vacuum Systems SELECTION TABLE The central vacuum unit Sistem CUBE was conceived to be used in a dome stic environment in situations in which the available room for installation is very limited The particular piping system with reduced diameter allows a hi gh suction power The installation cannot exceed three sockets Overall surface MODEL ARTICLE Maximumno of Maximum Vacuum discharge Dust bag Security filter Powersupply Motor power Maximum air areas sockets number of attachement capacity Litres Volt AC kW flow m h operators mm Sistem YES 220 240 The central vacuum unit Sistem CUBE is supplied with a complete cleaning accessory kit with 9 m hose Template for pre installation art 8300 10 RECOMMENDED INSTALLATION The central Sistem CUBE vacuum unit is suitable The template for the pre installation is the support for connecting the for installation on surfaces up to 120 with a central vacuum unit Sistem CUBE to the wall and allows a quick and precise maximum of three sockets installation The 40 mm diameter pipe all
94. central units ATTACHING THE SEPARATOR No particular attaching is required However you will have to check that the selected area for installation has the following minimum require ments to be correctly and safely positioned a solid resting surface a flat horizontal surface with no irregularities a surface unaffected by vibrations MEASUREMENT TABLES AND TECHNICAL DATA Dust separators ART 3200 0 3202 1 3200 0A 3202 1A MODEL LT 160 Separator with self cleaning Vacuum breaker safety valve IP insulation level IP Supply Volt ac Hz 220 240 Frequency kW 50 60 Compressor supply A 0 7 Absorption litres Air cylinder capacity m h Maximum air flow cm 1200 700 Filtering surface areas litres 43400 24000 Dust container capacity kg Weight mm Measurement A mm Measurement B mm Measurement C mm Measurement D mm Measurement E mm Measurement F mm Measurement G mm Measurement H mm Measurement L o mm Measurement M air inlet o mm Measurement N air outlet mm Measurement P mm Measurement R dB A Noise level lower than 68 68 N B Levels of nominal noise The levels can vary according to the speed of use environ ment where the system has been installed and the kind of installation www sistemair it rif 01 2008 ENG Dust Separators Blowing Power Units Range Periph
95. ck Mini Line Central Vacuum Cleaners up to 1200 m Block Maxi Line INDUSTRIAL Dust separators Blowing Power units Peripherals of central units INSTALLATION Installation Installation elements Sistem Case Installation Kit Electronic control systems Back plates and suction inlets Chase mounting plates Extension kit Domestic inlet valves Special inlet valves Valpan Cleaning accessories Complete accessories e Single accessories 2 32 mm e Single accessories 2 40 mm Special Cleaning separators Reel accessories EQUIPMENTS AND SYSTEMS Equipments Sistem Test SPARE PARTS Spare parts for domestic series Spare parts for professional series Spare parts for industrial series Alphabetic contents Article contents Description of homologation Compliance with regulations DOMESTIC Central vacuum cleaners Serie Tecno Activa Tecno Evolution performance noise tranquility mum www sistemair it HOUSES APARTMENTS VILLAS NIEW Central vacuum cleaners Series Tecno Activa Tecno Evolution i DOMESTIC Serie TECNO Evolution Generation Serie TECNO Activa Generation Up to 450 m 1 Operator DI Classe a a STANDARD MEDIA MINI TECNO Activa with built in computer 3yearWARRANTY INSTALLATION AREA 1
96. control panel Wall remote control panel with box Template for TA TE central vacuum units Expansion joint 50 PVC inspection screw cap 50 Expansion joint 63 Exhaust vent 50 Screw cap for installation testing Exhaust vent 63 Steel adapter 50 60 PVC inspection screw cap 63 Pipe adaptor 50 63 Cleaning accessory kit mod MINI Installation kit with 1 inlet valve 40 mm Installation kit with 2 inlet valves 40 mm Installation kit with 3 inlet valves 40 mm Installation kit with 1 square inlet valve 40 mm Installation kit with 2 square inlet valves 40 mm Installation kit with 3 square inlet valves 40 mm Installation kit with 3 inlet valves Installation kit with 3 square inlet valves Installation kit with 4 inlet valves Installation kit with 4 square inlet valves Installation kit with 5 inlet valves Installation kit with 5 square inlet valves Cleaning accessory kit mod ELITE On Off Cleaning accessory kit mod ELITE 7 m hose On Off Cleaning accessory kit mod ELITE 9 m hose Cleaning accessory kit mod ELITE 9 m hose Cleaning accessory kit mod STANDARD rif 01 2008 ENG Catalogue PAGE 59 59 59 69 69 83 152 83 152 151 85 83 83 83 151 145 104 104 104 107 104 104 107 104 104 104 144 144 144 111 111 111 110 110 144 105 105 105 105 106 105 107 105 105 132 35 35 35 35 35 35 108 108 108 108 108 108 155 134 134 133 155 ARTICLE DESCRIPTION 7032 1 7032 2 70
97. cting to the piping both from the right and left It is extremely quiet while running The micro line switch allows for maintenance operations At start up it has a reduction in absorption peak rif 01 2008 ENG Central vacuum unit Series TECNO Block Mini TECNO Block Maxi PROFESSIONAL central vacuum Systems CENTRAL UNIT SELECTION TABLE The central units can be used by a single operator on a maximum surface area of 600 The Tecno Block Mini central units can be selected with or without a programmable self cleaning system for the filter MODEL ARTICLE Maximum Centralunitwith Motor power Powersupply Maximum air Filtering Dust container number of self cleaning kW Volt ac flow m h surfaces cm capacity litres operators 3115 1MB 220 240 200 270 3115 2MB 220 240 200 270 N B These central unit models with electronic control system need an electric power line with wire no lower than 4mm The central vacuum units of the Tecno Block Mini series offer a high performance in any professional environment up to 600 53 rif 01 2008 ENG www sistemair it PROFESSIONAL Central vacuum unit Series TECNO Block Mini TECNO Block Maxi CONNECTION TO THE PIPING NETWORK ELECTRONIC SPEED CONVERTER Vent grate Silencer Electronic converter E Z Vacuum hose SUMMARY TABLE OF AVAILABLE SPEEDS AND KIN
98. d ABB Elos 1563 2 Generation inlet mod Ave Banquise Bianca Floor mounting plate aluminium 90 elbow 2 1563 0 Generation inlet mod Ave Blanc 1552 0 Generation inlet mod Ave Noir 1563 1 Generation inlet mod Ave Ral 1566 0 Generation inlet mod Bticino Axolute Nera 1567 0 Generation inlet mod Bticino Axolute Silver 1565 0 Generation inlet mod Bticino Light Tech 1561 0 Generation inlet mod Bticino Living Int 1562 0 Generation inlet mod Bticino Living Light 1568 0 Generation inlet mod BTicino Luna Bianca 1569 0 Generation inlet mod Bticino Matix 155751 Generation inlet mod Gewiss Chorus black 1557 3 Generation inlet mod Gewiss Chorus titanium Generation inlet mod Gewiss Chorus white 1557 0 Generation inlet mod Gewiss Playbus 1551 5 Generation inlet mod Legrand Vela bianca 1551 4 Generation inlet mod Legrand Vela nera 1558 0 Generation inlet mod Vimar Eikon 1553 0 Generation inlet mod Vimar Idea Nera Rond 1553 4 Generation inlet mod Vimar Idea Plana 15532 Generation inlet mod Vimar Idea Rond White 15585 Generation inlet mod Vimar Next 8080 3 Hose adaptor 63 80 7038 1 Hose end handle 40 70402 Hose extensions in plastic pair 32 7048 0 Hose fitting extension 32 7041 3 Hose reel trolley 32 7041 4 Hose reel trolley 40 7037 4 Hose sock 10 m 7037 1 Hose sock 7 m 7037 4E with ON OFF switch 7 m 7037 3E with ON OFF switch 9 m 1456 1 Industrial inlet valve with micro 32
99. d that the temperature inside does not exceed 40 C Depending on the model selected the rooms that will house the blowing units should have a suitable power supply At the planning stage it is advisable to identify the best location for the motor with respect to the system leaving a reasonable amount of space for installation use and maintenance You should also bear in mind the positioning of the air discharge piping to the outside and the piping coming from the vacuum system In the event of a system on several floors it should be installed on the bottom floor www sistemair it WITHOUT CONTROL PANEL WITH CONTROL PANEL INSTALLATION AREA The blowing power unit must be used in conjunction with the appropriate dust separator 80 litres and 160 litres The motors in this range are parts that are used on systems with the following characteristics piping network with main duct in the floor and 63 and 50 mm diameter pipe 63 80 100mm upright pipe depending on the selected configuration 380 V three phase power PARTICULAR CHARACTERISTICS OF THE PRODUCT Itis an industrial top performance three phase motor with blower light alloy si de channels and is maintenance free Vacuum channels and vertical discharge Electronic speed converter on pre fitted models The option of combining the motors fitted with electronic speed converter with external electronic control boards for maximum performance and consumption according
100. duce qj condensation inside the piping as much as possible as this could create incrustation if it were to come into contact with the dust Expansion joint www sistemair it rif 01 2008 ENG Notes on installation Standard mounting plate with elbow connector The standard mounting plate with elbow connector only 7 cm thick can be installed in any kind of wall The mounting plate is fitted with an elbow connector that rotates at 360 in order to position itself to the connec tor wherever it may be IMPORTANT the mounting pla te should always be installed flat into the wall CORRECT Installation Fitting the mounting plate with elbow connector Fitting the mounting plate with elbow connector to the wall or outside requires maximum precision so that when the inlet valve is fitted the holding ele ments adhere perfectly It is especially important the mounting plate box is completely flat into the wall INSTALLATION central vacuum systems Standard mounting plate with straight connector The standard mounting plate with straight connector should be regarded as a suitable part for all those unusual jobs restoration false walls partitions etc IMPORTANT the mounting plate should always be installed flat into the wall CORRECT Installation Fitting the mounting plate with straight connector Fitting the mounting plate with straight connector to the wall or outside requires maximum precisi
101. e positioning without incongruities that would make the central unit instable a solid resting surface a perfectly flat surface a surface unaffected by vibrations N B 1 for models with 2 or 3 operators the micro switch line has to be fitted with resistive dividers art 3301 4 in order to modulate performance N B 2 these central vacuum unit models fitted with electronic control system requiring suitable wiring 61 rif 01 2008 ENG www sistemair it Es i PROFESSIONAL Central vacuum unit Series TECNO Block Mini TECNO Block Maxi ST AN Y SO obe ERAS m N L 7 2 _ PX J A V TECHNICAL SPECIFICATIONS The main technical characteristics can be listed as follows Cylindrical frame in epoxy powder painted metal Base and supports in epoxy powder painted metal Metal dust container holds 60 litres with wheels for movement 20 Bag with bag string for dust collector 2V a The option of connecting to the piping both from the right and left ppeq e Motor pump unit with professional CE regulated motor IP55 cat insulation 22 category F Power varies according to model Z Motor noise level dB A from 68 to 85 according to the model 2 Electronic control system with self ventilation and safety system toprotectthe 7 2 unit under irregular working conditions and excessive increase in te
102. e bay The design of Wolly unit made of basic lines enriched of pearl white lacque ring allow his installation in any place 37 rif 01 2008 ENG www sistemair it L DOMESTIC Built in central unit 1 5 mm L Vac 220 240 N WOLLY ELECTRIC WIRING TERRA 250 SN 12 Q SOLN lt gt MR RA fayi A m NO Tr d M NE h P MICRO LINE 12 Vdc 430 MESUREMENT TABLES AND TECHNICAL DATA 6 7 WOLLY WOLLY 8200 0 8200 1 ART MODEL WOLLY 150 WOLLY 300 Maximum number of operators 630 Maximum surface 150 300 Maximum inlets Power Supply 220 240 220 240 Frequency 220 240 50 60 BEN Motor power 1 4 to 10 Absorption 5 6 6 5 2 O Maximum depression 2700 2900 Maximum air flow 170 175 Inlets supply 12 12 Security filter surface 2840 2840 Dust container capacity 12 12 Weight Kg 12 7 12 7 Width mm 630 630 Height mm 630 630 Depth mm 175 175 Vacuum attachment mm 40 50 40 50 Exhaust attachment mm eo INSTALLATION SOLUTIONS Frontal discharge Carried discharge
103. e cleaning hose or by using the micro switch from the handle of the flexible hose The standard inlet valves for square mounting plates come in just one model COMPATIBLE DECORATIVE PLAQUE B Ticino Matix B Ticino Axolute Nero B Ticino Axolute Silver B Ticino Luna bianca B Ticino Living International B Ticino Light B Ticino Light Tech Vimar Idea Nera Rond Vimar Idea Bianca Rond Vimar Plana Silver Vimar Plana Vimar Next Vimar Eikon Ave Noir Ave Blanc Ave Banquise Bianca Ave Ral Gewiss Playbus Gewiss Chorus bianca Gewiss Chorus nera Gewiss Chorus titanio mounting plates ABB Elos EM SISTEM AIR inlet valve ABB Chiara Legrand Vela Bianca Legrand Vela Nera 122 www sistemairit rif 01 2008 ENG Inlet valves MOUNT PLATES AND INLET VALVES COMPATIBLE DECORATIVE PLAQUE B TICINO SERIES OF GENERATION INLET VALVES central vacuum systems ARTICLE DESCRIPTION LIVING INTERNATIONAL GENERATION INLET VALVE PACKING PIECES LIVING LIGHT GENERATION INLET VALVE LIGHT TECH GENERATION INLET VALVE AXOLUTE NERA GENERATION INLET VALVE AXOLUTE SILVER GENERATION INLET VALVE LUNA BIANCA GENERATION INLET VALVE MATIX GENERATION INLET VALVE VIMAR SERIES OF GENERATION INLET VALVES rif 01 2008 ENG ARTICLE DESCRIPTION VIMAR IDEA BLACK RONDO GENERATION INLET VALVE PACKING PIECES VIMAR IDEA WHITE RONDO GENE
104. e inlet valve pack of 5 pieces Ivory finishing frame for square inlet valve pack of 5 pieces Round mounting plate 90 straight connector Round mounting plate elbow diam 50 mm Rectangular mounting plate straight connector with plaster guard 2 Floor mounting plate aluminium 90 elbow Floor mounting plate aluminium 90 elbow 2 Floor mounting plate aluminium straight union Floor mounting plate straight union Square mounting plate 90 elbow connector with plaster guard Square mounting plate elbow connector 2 Square mounting plate straight union Square mounting plate 2 straight union Extension kit for universal mounting plate Extension kit for square mounting plate Steel mounting plate for vacpan inlet valve Adapter for square mounting plate Floor inlet valve grey colour with micro 32 mm Floor inlet valve white colour with micro 32 mm Floor inlet valve brown colour with micro 32 mm Floor inlet valve black colour with micro 32 mm Floor inlet valve grey colour with micro 40 mm Floor inlet valve white colour with micro 40 mm Floor inlet valve brown colour with micro 40 mm Floor inlet valve black colour with micro 40 mm Industrial inlet valve with micro 32 mm External industrial inlet valve with micro 40 mm rif 01 2008 ENG Catalogue PAGE 153 153 153 149 150 158 153 153 151 151 151 153 75 75 75 75 75 75 75 105 105 105 105 107 106 105 107 106 105 106 127 127 116 117
105. e level of motor dB A N B Levels of nominal noise The levels can vary according to the speed of use environment where the central unit has been installed and the kind of installation rif 01 2008 ENG 63 ss www sistemair it PROFESSIONAL Central vacuum unit Series TECNO Block Mini TECNO Block Maxi SPARE PARTS TABLE TECNO Block Maxi ART MODEL 13200 0MB 32001 MB 3200 4MB 3200 6MB 3200 8MB 3200 3MB 3200 2MB 3200 5MB 3200 7MB 3200 9MB ARTICLE Filter cartridge 1610 2 Quantity 1 piece Dust bags eu Quantity 1 piece Air vent silencer 110002 Q Quantity 1 piece 3 Metal air vent silencer 11002 040002 Compressor for self cleaning Quantity 1 piece Solenoid valve for 040016 self cleaning Quantity 1 piece Electronic pressure switch for self cleaning Quantity 1 piece Electronic card os for self cleaning Quantity 1 piece 3 Motor start up card Quantity 1 piece Call selection card Quantity 1 piece 040020 Timer for self cleaning Quantity 1 piece www sistemairit rif 01 2008 ENG Central vacuum unit Series TECNO Block Mini TECNO Block PROFESSIONAL central vacuum Systems ACCESSORIES TABLE TECNO Block Maxi ART MODEL 3200 08 32001 MB 3200 4MB 3200 6MB 3200 8MB 3200 3MB 3200 2MB 320
106. er Adjustable vacuum breaker compensation valve Daily or weekly management of the self cleaning cycle using a programmable timer Filter cartridge with a high filtering capacity Dust bag for dust container fitted with metal bag string SELECTION CRITERIA The 80 litre dust separator was designed for systems that can cover up to 700 m h The 80 litre separator is a recommendable choice for small businesses and industries The 160 litre separator was designed for systems that can co ver up to 1200 m3 h This separator is a recommendable choice for use in large businesses or industries rif 01 2008 ENG Dust Separators Blowing Power Units Range Peripherals of central units INDUSTRIAL i central vacuum Systems SEPARATOR SELECTION TABLE The SISTEM AIR dust separators for industrial use offer numerous possibilities for use thanks to their versatility and flexibility in combining with the other com ponents of an industrial central vacuum system There are two versions of dust containers with different capacities and can be used in both large and small industrial environments The choice depends on the total air flow in the motors they are coupled with the number of people using it and the possibility of having a programmable self cleaning system for the filter As the industrial dust separators are part of the system it is advisable to make your choice after careful consideration bearing in mind how it will be used and the kind o
107. er 220 240 220 240 220 240 220 240 220 240 220 240 220 240 1220 240 220 240 220 240 220 240 220 240 220 240 i 50 60 50 60 50 60 50 60 50 60 50 60 N Motor power kW 13 L3 1 4 1 3 14 1 9 Absorption 5 6 5 6 6 5 5 6 6 5 8 2 Socket supply Volt dc 12 12 12 Maximum air flow m h 234 309 320 Filtering surface areas 3100 6700 6700 6700 6700 6700 6700 Dust container capacity 21 21 Air vent YES YES YES Air discharge silencer YES YES YES Weight kg 8 5 19 19 Measurement A mm 210 230 230 Measurement B mm 325 370 370 Measurement C mm 345 380 380 Measurement D mm 168 185 185 Measurement E mm 108 195 195 Measurement F mm 315 585 585 Measurement G mm 650 915 915 Measurement H mm 100 100 100 00 Measurement X mm wwe 500 500 350 350 500 500 500 500 N B Levels of nominal noise The levels can vary according to the environment where the central unit has been installed and the kind of installation 18 www sistemair it rif 01 2008 ENG Central vacuum Series Tecno Activa Tecno Evolution SPARE PARTS TABLE TECNO Evolution Generation ART 3107 17E MODEL TE ARTICLE EN Filter cartridge 3108 1TE 3109 1TE MEDIA MEDIA PLUS TE 3110 1TE SA 50 3112 1TE SA 100 3113 1TE SA 200 3115 1TE 3107 1TA DOMESTIC central vacuum Systems TECNO Activ
108. erals of central units INDUSTRIAL a central vacuum Systems SPARE PARTS TABLE Polyester filter cartridge Quantity 1 piece Dust bags Quantity 20 pieces Compressor for self cleaning Quantity 1 piece Solenoid valve for self cleaning Quantity 1 piece Electronic pressure switch Quantity 1 piece Electronic board for self cleaning Quantity 1 piece Rotating nozzle Quantity 1 piece Self cleaning timer Quantity 1 piece rif 01 2008 ENG Dust separators 3200 0 3202 1 3200 0A 3202 1A LT 80 LT 160 LT80 160 C A C A ART MODEL ARTICLE 1610 2 1610 4 040023 www sistemair it INDUSTRIAL Dust Separators Blowing Power Units Range Peripherals of central units Blowing Power Units Range Qo 74 RECOMMENDED INSTALLATION The motor bodies are ideal for installation in industrial and business environments hotels public offices industries and can be used individually or together with other motors It is essential to use them in conjunction with a dust separator They should be installed in service rooms that are closed and protected from extreme weather conditions dampness Jl e sees ou should also choose areas at some distance from heat sources such as heaters or central heating IP20 insulation level Ensure the selected installation rooms are well aired an
109. es and connections built to guarantee endurance and electric transmission in all the contexts where these characteristics are essential for the correct installation STEEL PIPE 1850 0F Steel pipe 50 2 bars ARTICLE DESCRIPTION PACKING pcs 1863 0F Steel pipe 60 2 m bars 45 ELBOW PIPE 3050 1F Elbow pipe 45 Male Male 50 3063 1F Elbow pipe 45 Male Male 60 90 ELBOW PIPE ARTICLE DESCRIPTION PACKING pcs 3050 0F Elbow pipe 90 Male Male 50 3063 0F Elbow pipe 90 Male Male 60 45 DERIVATION PIPE 7 ARTICLE DESCRIPTION PACKING pcs 4050 0 Derivation pipe 45 Male Male Male 50 JUNCTION GROUPS 1150 1F Junction group steel pipe 50 1163 1F Junction group steel pipe 60 5 ARTICLE DESCRIPTION PACKING pcs STEEL ADAPTER ARTICLE DESCRIPTION PACKING pcs 6050 0F Steel adapter 50 60 1 107 rif 01 2008 ENG www sistemair it QU INSTALLATION Installation materials INSTALLATION KIT The installation kit includes everything needed to fit a central vacuum system The installation kits can be combined to obtain the number of sockets you wish to install e g 8 socket system can be created by combining 1 kit with 3 sockets 1 kit with 5 sockets alternatively 2 4 socket kits can be used The list of material contained in the kit can be checked in the tables below N B The installation kit is made with
110. ety and quality homologations and certifications that satisfy even the most difficult system re quirements PVC piping with static load reduced to a minimum UNI approved grey piping Rigid piping with connectors that have a wide radius of curving Connectors with angular reference notches for a correct coupling between piping and connectors PVC plastic material that can be welded cold using a special glue Fire resistant PVC material in compliance with M1 resistance cat and IEC regu lations Grey 16 mm pre wired conduit with CE IMO labelling suitable for ordinary and unusual environments where you need to use non toxic products Certification from the Italian Institute of Plastics in compliance with UNI regu lations Main charcteristics Rigid piping with connectors that have a wide radius of curving PVC plastic material that can be welded cold using a special glue Certification of the Italian Institute of Plastics in compliance with UNI regulations Fire resistant PVC mate rial in compliance with CEI 23 29 regulations Criteria for choosing the piping network The PVC piping and connectors are suitable for all kinds of centralised vacuum system installations Aluminium piping can be used where there are particular mechanical resistance problems or when installing visible piping Technical note When it is necessary to cross an external section with a rigid pipeline it is op portune to prepare a su
111. f system as well as the other parts needed to obtain a complete central vacuum system Motor air MODEL ARTICLE Self cleaning Dustcontainer Filtering Max number of operators with Max number of Volt ac power flow capacity surfac 32 Flex hose operators in cm with 40 Flex hose LT 80 3200 0 LT80 C A 0107 LT 160 3202 1 LT 160 220 240 TECHNICAL NOTE The 80 litre dust separator can be used by as many as 4 operators simultaneou sly with a 32 mm flexible hose With the 40 mm hose the number of ope rators drops to 3 The 160 litre dust separator can be used by as many as 6 operators simultaneou sly with a 2 32 mm hose With the 2 40 mm hose the number of operators drops to 4 Thanks to their modularity Sistem Air industrial units always allow to find the right solution as to suction power and quality in any situation 69 rif 01 2008 ENG www sistemair it i INDUSTRIAL Dust Separators Blowing Power Units Range Peripherals of central units CONNECTION TO THE SEPARATE AND ROTATING PIPING SELF CLEANING ON PRE FITTED MODELS The option of having two separate openings one on the right the The separator can be fitted with programmable self cleaning other on the left to connect to the system s vacuum piping and air to clean the filter cartridge that is made up of a programmable discharge timer compressor and storage cylinder for compressed air The
112. filter is cleaned and blown from inside with a strong jet of com pressed air at programmable intervals Connection hose to the blowing power unit inlet Cylinder Programmable timer Piping network Co vacuum hose Ve Se SRS SSeS Sb SoS SSeS DISCHARGE WITH HANDLE DUST CONTAINER ON WHEELS Handle for releasing dust container Dust bag Wheels for movement 70 www sistemair it rif 01 2008 ENG Dust Separators Blowing Power Units Range Peripherals of central units TECHNICAL SPECIFICATIONS The Industrial series of dust separators have been designed and built in compliance with current legislation and EU directives without however neglecting the fundamental elements such as operational ability power and practicality of use Its main technical characteristics can be listed as follows Base and supports in epoxy powder painted metal Cylindrical frame in epoxy powder painted metal Opening of the dust container with handle to make it easier to empty it Metal dust container with wheels for movement Bag and bag string in the dust collector to rapidly and hygienically dispose of vacuumed matter The polyester filter cartridge with a vast filtering surface area is certified BIA USG and can be washed with water Adjustable mechanical compensation valve to deal with the vacuum flow The option of having two separate openings one on the right the other on
113. filtration of water P2 44 Apparatus protected against solid parts larger than 1mm and protected against water sprays water sprayed on the cove ring from any direction should not cause damage IP X4 Apparatus protected against water sprays water sprayed on the covering from any direction should not cause damage gt lt P Level of electric insulation CLASSE I Apparatus with fundamental electric insulation It should connected to the earth circuit on the main electric power CLASSE Apparatus with dual electric insulation It does not need to be connected to the earth circuit of the main electric power a Compliance with harmonised regulations DOMESTIC SECTOR Serie JOLLY Apparatus complies with the following regulations EN 60335 2 2 1995 A1 1998 A2 2000 EN 61000 3 2 2000 EN 61000 3 3 1995 A1 2001 EN 55014 1 2000 A1 2001 A2 2002 EN 55014 2 1997 A1 2001 Series TA TE Apparatus complies with the following regulations EN 60335 2 2 2003 A1 2004 A2 2006 EN 60335 1 2002 A11 2004 A1 2004 A12 2006 A2 2006 EN 50366 2003 A1 2006 Series TECNOSTAR Apparatus complies with the following regulations 98 37 CEE Machine directives former 89 392 CEE and later changes 73 23 Low Voltage Directive and later changes 89 336 CEE Electromagnetic compatibility directive and later changes Series Sistem Cube Apparatus complies
114. for 0110001 motor coupling Quantity 1 piece 2 Quantity 1 piece Solenoid valve 3 Retention valve for 0110003 for self cleaning Q motor coupling Quantity 1 piece wy Quantity 1 piece Electronic pressure 6 switch for self cleaning Quantity 1 piece 4 Retention valve for motor coupling gt SE Quantity 1 piece Electronic board for self cleaning Quantity 1 piece 2 air vent silencer F Quantity 1 piece 3 air vent silencer Mi Rotating nozzle 030025 Quantity 1 piece Quantity 1 piece Timer for ai Piu self cleaning Quantity 1 piece 4 air vent silencer 7 5 S Quantity 1 piece SPARE PARTS FOR SISTEM TEST Sistem TEST 4300 1 Sistem TEST ARTICLE Polyester filter 1610 16 cartridge Quantity 1 piece 1614 15 Bags Quantity 1 piece Motor 1623 16 Quantity 1 piece NAV Motor brushes 1611 16 gt Se Quantity 2 pieces rif 01 2008 ENG 154 ALPHABETIC CONTENTS ARTICLE 7034 2 060005Q 060005QE 0110001 11001 040002 0110003 11002 060006Q 060006QE 0110002 11003 3010 1 3050 1 3063 1 3080 1 3010 0 3050 0 3063 0 3080 0 060008Q 060008QE 060010QE 7041 0 7032 3 7041 2 1450 18 1863 0A 1850 0A 7033 7 1614 15 8220 0 7034 3 7047 1 7049 0 7033 8 7033 1 7044 0 7033 2 7034 0 7034 1 7100 2
115. g plate 90 elbow diam 50 mm Screw cap for installation testing Silencer in PVC 50 2 Silencer in PVC 63 Sistem Case Sistem Cube central vacuum unit Solenoid valve for self cleaning system Spare wheel for pipe cutters Special glue 500 g without brush Special glue 250 g with brush Special glue 500 g with brush Special glue in a tube 60 g Speed modulation circuit board Square inlet valve aluminium color Square inlet valve ivory colour Square inlet valve white colour Square mounting plate 2 straight union Square mounting plate 90 elbow connector with plaster guard Square mounting plate elbow connector 2 Square mounting plate straight union Steel adapter 50 60 Steel key for floor inlet valves Steel key for protected Ave Living inlet valves Steel mounting plate for vacpan inlet valve Steel pipe 50 mm Steel pipe 60 mm Stop coupling PVC 100 Stop coupling PVC 50 www sistemair it Catalogue PAGE 137 151 106 106 106 106 106 106 106 105 105 105 104 104 104 144 144 104 104 104 104 104 104 104 104 104 136 Wy 116 116 117 85 153 118 118 106 149 150 103 21 151 144 106 106 106 106 83 125 125 125 117 116 117 116 107 lay 127 128 107 107 105 105 ARTICLE 1163 1 1180 1 93012 4200 2 4200 3 3115 2MB 4300 0 040020 20277 1614 4 7033 3 70392 1464 5 1464 3 14642 4001 0 7038 2 7038 0M 4200 6 4200 0 4200 7 1450 10 8200 0 8200 1 DESCRIPT
116. g to the environment where the central unit has been installed and the kind of installation Art 8500 0 Art 8500 1 Size of Jolly box wall box Size of Jolly box external box 175 155 Art 8510 0 Art 8510 1 Direct discharge overall size Size of side discharge set 210 050 51 _ 395 48 wwwistemairit rif 01 2008 ENG JOLLY SYSTEM DOMESTIC central vacuum systems BASIC SET It is a tool that allows for the insertion of the Jolly in the centre of the house which equipped with air discharge to outside piping and accessories allows the air to be discharged outside Art 8500 0 Size of Jolly box wall box A a C EN D vum ai i m 7 155 Y oy NS T x Mc rc KR n Art 8500 0 Art 8500 0 Art 8510 1 H 2 Depth of Jolly Box Depth of Jolly Box side discharge m L dis EELE E E bere ol cap ee e e oe e NA 175 185 MATERIAL CONTENT IN THE BASIC SET 8600 2 d H 8500 0 Jolly wall box Art 8510 1 1 Size of Jolly 8510 1 1 Side discharge 110001 PVC silencer 5050 4 50 vent grate 210 3050 0 50 45 M F PVC elbow plat 3050 1 50 45 F F PVC elbow 395 1150 1 50 F F PVC coupling 1850 0 50 PVC hose 9225 3 Special glue
117. hannel light alloy cover with top performance and maintenance free Performance varies according to the model Motor noise level dB from 68 to 85 depending on the models and perfor mance Electronic speed converter with self ventilation and safety system to protect the unit Under irregular working conditions or excessive increase in tempe rature the converter intervenes to automatically turn off the central vacuum unit only on pre fitted models Electronic card for controlling speed and performance allows you to optimise the vacuuming strength proportioning consumption only on pre fitted mo dels 380 V general power depending the model Vacuum power sockets with 12 V dc voltage Magnet thermal protection switch on the control panel Circuit breaker switch for the micro line Main switch Option of multiple installation with several motors linked to each other N B in order to obtain the electronic speed modulation the motor bodies with electronic control system need a micro line on the vacuum system fitted with resistive dividers Parts no 3301 4 Note During installation check that the absorption of the motor body does not exceed the data shown on the technical data plaque Should the absorption be greater than the levels on the plaque slacken the regula tion of the vacuum breaker valve located on the dust separator until the levels are once again stable rif 01 2008 ENG
118. if 01 2008 ENG 220 240 RECOMMENDED INSTALLATION The Jolly vacuum system does not require a piping network and can be installed both in houses under construction or finished homes in walls at least 25 cm thick If it is impossible to build it into the wall it can be placed in a spe cial box for outside that will be attached to the wall It can be installed anywhere as long as the selected location is protected from extreme we ather conditions and atmospheric agents dam pness and excessive temperature changes It would also be best to place it at some distance from heat sources such as heaters or central he ating IP 20 insulation level for apparatus There should be sufficient illuminated space around the apparatus to make it possible to change the dust bag and carry out any maintenance work The discharge of air outside a necessary con dition to be able to expel the micro dust that the filter bag cannot contain can be done in different ways either with direct discharge or side discharge using an outlet extension The external discharge point should not be blocked in any way and positioned in such a way so it does not damage or disturb other structures At the planning stage it is advisable to identify the best location for the apparatus so that you can reach as many parts of the house as possi ble with the vacuum hose You should consider installing more than one apparatus in the same house www sistemair it
119. in two other versions grained wood and light carbon Insulation category 2 it does not require to be earthed MAIN CHARACTERISTICS The construction is made entirely of vibration proof and sound proof plastic It offers the possibility of attaching any accessory found in the catalogue Installation and layout of the system are economically advantageous Vacuum module available in two versions with standard hose Jolly or with low voltage hose fitted with on off switch Jolly Contact 42 www sistemair it rif 01 2008 ENG JOLLY SYSTEM SELECTION TABLE The Jolly and Jolly Contact vacuum modules have the same motor power the same construction technology and the same performance The Jolly Contact vacuum modules can also be used with an electric hose with on off switch and start up control on the handle Overall surface MODEL ARTICLE Socket Max Attachment Dust bag areas points numberof X forlow capacity operators voltagehose litres JOLLY 220 240 DOMESTIC central vacuum Systems Power Motor power Maximum air supply Watt flow m h Volt ac JOLLY Contact TRADITIONAL INSTALLATION Creating hole in the wall to house the Jolly Box N N W Jolly installation amp N INSTALLATION IN FINISHED HOUSES Creating a minimum hole to house the Jolly Jolly installation EXTERNAL INSTALLATION ON THE WALL External box r
120. itable isolation with the addition of expansion joints art 5050 0 Warning The installation material such as pipes and connectors has been specifically designed and created for central vacuuming Using the specific installation ma terial allows you to create systems with a maximum guarantee on performance and the assurance that it will not block Any other material would jeopardise the system s warranty and could create blocking in the piping network 102 ___ www sistemair it rif 01 2008 ENG Installation materials INSTALLATION central vacuum Systems SISTEM CASE Sistem Case is a new case to build in Sistem Air central units especially developed to save space and to aesthetically integrate the vacuum unit in the wall It is realized in strong zinc coated steel and thanks to its telescopic structure it fits any MINI and MEDIA Sistem Air vacuum unit With a single code you can match different installation needs The cover made of plastic material in aluminium colour has a futuristic and at the same time simple design It is available in two different versions depending on the kind of central unit to be installed Sistem Case is only 23 cm deep and allows the connection to the piping system from the left or from the right ARTICLE PRODUCT DESCRIPTION Packaging pieces 7100 0 Universal case to build in units MINI e MEDIA 1 CASE COVER 7100 1 Case cover for unit
121. its the absorption peak current The electronic system with resistive choke dividers allows you to modulate the power absorbed with respect to the number of operators actually working Ki TOP OF THE RANGE SOLUTION As well as the characteristics found in the ideal solution it also comes with an electronic control panel that allows you to divide the use of the motors on the basis of the operators actual needs this system allows you to manage a conside rable rationalisation of consumption while the system is being used 87 rif 01 2008 ENG www sistemair it INDUSTRIAL Dust Separators Blowing Power Units Range Peripherals of central units a Max number of operators 1 Max no of sockets 40 ARTICLE PRODUCT DESCRIPTION ARTICLE PRODUCT DESCRIPTION 80 litre dust separator 380 V 2 2 kW blowing power unit complete with control panel 2 metal silencer 3200 0A 80 litre dust separator with self cleaning filter 444429424 380 V 2 2 kW electronic blowing power unit complete with control panel 11001 2 metal silencer 88 ENS Jwww istemairit rif 01 2008 ENG Dust Separators Blowing Power Units Range Peripherals of central units INDUSTRIAL central vacuum Systems e M Max number of operators 2 Max no of sockets 60 PRODUCT DESCRIPTION ARTICLE Quantity 80 litre dust separator UU eR 380 V 4 kW blowing power unit comp
122. k and ensure optimum running of the system thus keeping a steady performance over time Cut of the piping and proper joining of connectors In order to cut the pipes properly use ONLY cylindrical pipes should ALWAYS be placed correctly they should al pipe cutting tool ways be inserted till it reaches the ledge X RIGHT cut and WRONG positioning PROPER equipment RIGHT cut and RIGHT positioning Examples of WRONG pipe cutting UNSUITABLE tool for cutting Example of cut made with an unsuitable tool X WRONG Equipment X WRONG Installation 96 DP wwwsistemair it rif 01 2008 ENG Notes on installation INSTALLATION i central vacuum systems Gluing the piping to the connectors The stage of gluing the piping to the connectors is without a doubt the most delica te stage of the central vacuum system because if it is not carried out properly there could be a loss in flow of the system Overtime this would cause sedimentation of the vacuumed product inside the piping located into chase The operation is carried Glue out properly by spreading the glue only on the piping or on the male part of the connector This ensures that when the piping is fitted to the connector any excess glue will overflow creating an extra hold ring If the operation were to be done the other way round that is soreading the glue onto the female part of the connector 222 the excess glue would drip inside the piping when it is fitted
123. ke back to collective and or vertical building CHARACTERISTICS OF PRODUCT Thanks to IP 44 insulation level the installation is allowed even in humid places on balconies and boiler rooms They are equipped of safety thermic sensor for protection of motor with switching off and automatic restoration in case of fault Possibility of connection to pipes net with dust entry on right and on left while the air discharge can be carried left right or frontal They are predisposed to accept pipes of diam 40 and 50 mm Filter cartridge with advanced technology Soft Start device to reduce consumption during the motor start High soundproofing level thanks to adoption of sound absorbent devices for all unit components Built in case of installation proneness Pearl aesthetic finishing Equipped with dedicated accessories kit MAIN CHARACTERISTICS Thanks to last generation motors and to careful planning the Wolly unit allows to do cleaning on surfaces up to 300 mq in only 63 cm of hight and 43 cm of width and with a thickness of only 17 5 cm the Wolly unit can be easily positioned on balconies and perimeter walls A particular care has been placed during the planning phase to the reduction of unit noisiness using sound absorbent materials on the different components of the machine along with the used technical details Wolly is the built int unit at the top of the class in quiteness terms rif 01 2008 ENG Built in
124. ke the central unit instable CONNECTION TO THE PIPING NETWORK The inlets for the connection to the piping network and air vent piping to the outside can be positioned either on the left or right of the central unit TABELLE MASSE UND TECHNISCHE DATEN TECNO Star ART 3115 0TS MODEL TECNO Star Computer maintenance YES Vacuum attachement 60 IP insulation level 20 Ac power 220 240 Frequency 50 60 Motor power 1 4x2 Absorption 13 Socket dc power supply Volt dc 12 Maximum air flow 365 Filtering surface areas 16600 Dust container capacity 60 Air vent YES Air discharge silencer NO Weight kg 55 Measurement A mm 570 Measurement B mm 500 Measurement C mm 1230 Measurement D mm 810 Measurement E mm 275 Measurement F mm 140 Measurement G mm 615 Noise level with 1 motor dB A 64 Noise level with 2 motors dB A 69 N B Levels of nominal noise The levels can vary according to the speed of use environment where the central unit has been installed and the kind of installation 26 www sistemair it Central vacuum Series TECNO Star Vent grate C Discharge pipe Ir quee RI rif 01 2008 ENG Central vacuum Series TECNO Star DOMESTIC central vacuum Systems SPARE PARTS TABLE TECNO Star ART 3115 0TS TECNO STAR ARTICLE Filter cartridge Quantity 1 piece
125. le the other s are off ARTICLE MEASUREMENT Hose DIAMETER Amm PACKAGING pieces 0110001 2 63 52 0110003 0110002 AIR VENT SILENCER The air vent silencer is installed directly on the motor body in order to lower the noise level Should you wish to make it even quieter more silencers can be added ARTICLE MEASUREMENT Hose DIAMETER mm PACKAGING pieces 11001 84 m J www istemairit rif 01 2008 ENG central vacuum Systems RESISTIVE DIVIDER CARD The resistive divider is essential when you want to modulate the speed of a mo tor body or control the turning on and off of more than one motor body Fach divider can hold up to four inlet valves that can be linked up to each other with no maximum limit Wall box EXPLANATORY DRAWING OF CONNECTION EXAMPLES Clamps for MICRO line cable connections N B the connection of the MICRO line inlet and outlet clamps can be carried out indifferently by both sides see example shown below LI N E N S SISTEM AIR 3301 4 Q LI N E OUT 12 12 Vdc 909090692 LI N E O UT SISTEM AIR 3301 4 LI N E n 12 mp Im 12 909092692
126. lete with control panel 3 metal silencer ARTICLE PRODUCT DESCRIPTION Quantity SPATE 80 litre dust separator with self cleaning filter 444949427 380V 4 kW electronic blowing power unit complete with control panel 2 metal silencer Control panel for the modulation of the electronic motors ARTICLE PRODUCT DESCRIPTION Quantity LEM 160 litre dust separator with self cleaning filter 4454297 380 V 2 2 kW electronic blowing power unit complete with control panel 2 metal silencer 0110001 Q 2 retention valve for the coupling of more than one motor 89 rif 01 2008 ENG www sistemair it ii INDUSTRIAL Dust Separators Blowing Power Units Range Peripherals of central units FAN Max number ofoperators 3 Max no of sockets 80 ARTICLE PRODUCT DESCRIPTION Quantity 160 litre dust separator 4 445907 380 V 5 5 kW blowing power unit complete with control panel 3 metal silencer ARTICLE PRODUCT DESCRIPTION PAPAIN 160 litre dust separator with self cleaning filter 444959424 380 V 5 5 kW electronic blowing power unit complete with control panel Control panel for the modulation of the electronic motors 3 metal silencer ARTICLE PRODUCT DESCRIPTION PAPAIN 1060litre dust separator with self cleaning filter 4442977 380 V 2 2 kW electronic blowing power unit complete with control panel 2 metal silencer 3
127. mperatu 2 re the system intervenes to automatically turn off the central vacuum unit on gt pre fitted models 24 General single and tri phase power depending on the model Power to inlet valves with 12 V dc power Circuit breaker switch for the micro line BIA USGC certified polyester filter cartridge washable with water filtering surface of 24 000 cm Electronic card to control speed on pre fitted models Mechanical vacuum breaker valve to regulate the vacuum flow Programmable self cleaning to clean the filter cartridge on pre fitted models The system comes with a compressor and accumulation cylinder 20 litres for mm Cover the compressed air that is discharged into the filter at programmable inter B Electronic converter for motor speed only on pre vals fitted models Silencer for air discharge provided 3 Control panel Handle for releasing the dust container 5 External front cover 6 Handle 7 Dust container 8 Base 9 Main switch 10 warning light 11 Micro line switch 3 12 Clock for self cleaning cycles only on models with I q self cleaning l SIB 13 Side cover 10 uror c 54 14 Blowing motor unit 11 15 Internal front cover 12 16 Air vent 17 Control panel 18 Dust separator compartment 19 Filter cartridge 20 Dustinlet 21 Conveyor cone 22 Bagstring 23 Dust bag 24 Wheels 62 www
128. nance cycles he machine unit features epoxy powder painted metal with a support base and dust container fitted with wheels to make emptying it easier Electronic selection and motor start up board to reduce absorption peak at start up rif 01 2008 ENG Central vacuum Series TECNO Star DOMESTIC i central vacuum Systems CENTRAL UNIT SELECTION TABLE The TECNO Star central units are fitted with two motors whose intervention method depends on how the central unit is used and by the number of micro lines that have been connected up and are in operation It is in fact possible to connect 2 micro lines to the central unit that cover two different areas of the vacuum system for example two areas of the same system two levels or two separate apartments In fact it is possible to choose whether to vacuum one single area covered by one micro line with or without greater power single operator or distribute the maximum power to vacuum two covered areas from two separate micro lines with two operators simultaneously within the same small domestic area NOTE Two operators are not possible if the overall surface area is greater than 350 m ar if the piping network has not been correctly dimensioned The central vacuum units should be selected according to the surface area to be cleaned in order to ensure long life and maximum performance over time See Chapter dedicated to Plant Engineering Overall surface MODEL ARTICLE
129. nd restart Attachment for low voltage hose Only for Jolly contact 1 Upper hatch 2 Safety fuse Starter button Jolly Increase in voltage button jolly contact 4 Hose positioning guide 5 Hose attachment 6 Casing for lower door hooks 7 Lower hatch hooks 8 Lower hatch 9 Frame 10 Bag replacement light 11 Motor filter 12 Bag container 13 Location for installation sponge without Jolly box 14 Terminal board for electrical connection 15 Duct closure hatch 16 Pressure switch 17 Serial no plaque and technical data 18 Cir discharge pipe 19 Coupling flange on jolly box 47 rif 01 2008 ENG www sistemair it 5 JOLLY SYSTEM MEASUREMENT TABLES AND TECHNICAL DATA JOLLY serie 8710 0 8720 0 ART MODEL JOLLY Attachment for low voltage hose NO YES Vacuum attachment mm 40 40 IP insulation level IP 20 20 Volt ac power Volt ac 220 240 220 40 Frequency Hz 50 60 50 60 Motor power kW 1 1 Art 8710 0 Art 8720 0 l Size of Jolly Jolly contact 205 la 022 Maximum air flow m h Protection fuse ra Dust bag capacity LITRES 3 3 Air vent YES YES Air discharge silencer Supply to low voltage pipe Volt dc 438 Weight kg 3 8 3 8 33 142 175 Noise level lower than dB A 70 N B Levels of nominal noise The levels can vary accordin
130. oise level dB A from 60 to 50 Hz 72 to 60 Hz Controlled electronic speed converter with self ventilation and safety system to protect the unit under irregular working con ditions and excessive increase in temperature the converter intervenes to au tomatically turn the motor on the central vacuum unit off Single phase general power Vacuum power sockets with 12 V dc voltage Circuit breaker switch for the micro line BIA USG certified polyester filter cartridge washable with water filtering surfa 2 a of 1 7 800 cm f 1 Control panel Silencer for air discharge provided Possibility of selecting one of two operating speeds 2 Electronic converter for motor speed Mechanical vacuum breaker valve to regulate the vacuum flow BE Programmable self cleaning to clean the filter cartridge optional The system comes with a compressor and accumulation cylinder 20 litres for the com pressed air that is discharged into the filter at programmable intervals 5 Filter cartridge 4 Dust separator compartment 6 Conveyor cone 7 Bag string 8 Dust bag 9 Base 10 Main switch 11 Warning light 12 Micro line switch 13 Clock for self cleaning cycles only on models with self cleaning 14 Cover 15 Air vent 16 Side cover 17 Blowing motor unit 18 Control panel 19 Closure hook 20 Dustinlet 21 Handle 22 Dust container
131. on inlet mod Gewiss Chorus white Generation inlet mod Gewiss Chorus black Generation inlet mod Gewiss Chorus titanium Generation inlet mod Vimar Eikon Generation inlet mod Bticino Living Int Generation inlet mod Bticino Living Light Generation inlet mod Ave Blanc Generation inlet mod Ave Ral Generation inlet mod Ave Banquise Bianca Generation inlet mod Bticino Light Tech Generation inlet mod Bticino Axolute Nera Generation inlet mod Bticino Axolute Silver Generation inlet mod BTicino Luna Bianca Generation inlet mod Bticino Matix Filter cartridge for TE TA central units Filter cartridge in polyester for MINIBLOCK Filter cartridge in polyester for SISTEM CUBE Filter cartridge in polyester for dust separator LT 80 Tecno Block Maxi Filter cartridge in polyester LT 160 Filter cartridge in polyester for MINI TA TE models Filter cartridge in polyester for TECNOSTAR units Filter cartridge in polyester for Wolly Motor brushes for SA50 100 Mini Med M Plus TE TA Generation Motor brushes for SA200 400TE TA Generation Motor brushes for Sistem Cube Motor brushes for 5 050 central units Motor brushes for SA100TE TA central units Motor brushes for SA200TE TA central units Motor brushes for SA400 TE TA central units Motor brushes for MEDIA PLUS central units Motor brushes for TECNO STAR central units Electronic card for TE TA central units Computer circuit board for TECNO Activa central units Electronic board for computer Elec
132. on so that when the inlet valve is fitted the holding elements adhere per fectly It is especially important the mounting plate box is completely flat into the wall INCORRECT Installation rif 01 2008 ENG INCORRECT Installation 99 www sistemair it ia INSTALLATION Notes on installation EXAMPLE OF BASE CONNECTIONS Example of base connection to install the inlet valve SMe N lt mes SSL OY 24 Hm Dl ARTICLE PRODUCT DESCRIPTION 1850 0 50 mm thick PVC pipe 2 2 4050 1 50 mm 45 PVC derivation 3050 0 50 mm 45 MF PVC elbow connector 1450 0 Standard mounting plate straight connector with cover 9016 7 2x1 25 m pre wired conduit 9016 0 2x1 50 m pre wired conduit 9016 1 2x1 100 m pre wired conduit EXAMPLE OF CONNECTION TO INLET VALVES Example of connection to inlet valves Rectangular mounting plate Clamps on the wall 100 wwwsistemair it rif 01 2008 ENG Notes on installation INSTALLATION i central vacuum systems EXAMPLE OF DOMESTIC SYSTEM ON THREE FLOORS Example of sized system to be used by only one operator at the most on each floor NB all the systems in the domestic range can only have one operator at a time The system in question is created in a domestic structure on three floors The piping will be exclusively 50 mm both as regards the upright pipe and the dist
133. onduit STANDARD RECTANGULAR MOUNTING PLATE ARTICLE DESCRIPTION Packing pieces STANDARD MOUNTING PLATE elbow connector with cover STANDARD RECTANGULAR MOUNTING PLATE ARTICLE DESCRIPTION Packing pieces 1450 1 STANDARD RECTANGULAR 10 mounting plate STANDARD SQUARE MOUNTING PLATE ARTICLE DESCRIPTION Packing pieces 1450 4B STANDARD MOUNTING PLATE elbow 10 connector with cover STANDARD SQUARE MOUNTING PLATE ARTICLE DESCRIPTION Packing pieces 1450 5B STANDARD MOUNTING PLATE straight 10 connector with cover re www sistemairit rif 01 2008 ENG Mounting plates MOUNTING PLATES FOR INLET VALVES 2 PIPING The standard rectangular mounting plates with elbow connector are suitable for all the inlet valves that accept the decorative plaques while the square mounting plates are suitable for the inlet valves already complete with aesthetic finishing in two different colours Each model has set notches for the pre wired conduit N B Mounting plates suitable for use with 2 piping ARTICLE MOUNTING PLATES STANDARD RECTANGULAR MOUNTING PLATE DESCRIPTION central vacuum Systems Packing pieces 1450 0E STANDARD RECTANGULAR MOUNTING PLATE ARTICLE 1450 1E STANDARD MOUNTING PLATE elbow connector with cover DESCRIPTION 10 Packing pieces STANDARD MOUNTING PLATE straight connector with cover
134. onnect the unit to the system A universal adapter A full kit of test plugs to test the system A strong and practical bag to transport easily and conveniently the whole kit SPARE PARTS Sistem TEST ART 4300 1 Sistem TEST ARTICLE Filter 1610 16 Quantity 1 Piece Dust bag 1614 15 Quantity 20 Pieces Moto MAC Quantity 1 Piece Motor brushes 1611 16 Quantity 20 Pieces rif 01 2008 ENG MATERIAL CONTENT IN SISTEM TEST ART 4300 1 DESCRIPTION EQUIPMENT AND SYSTEMS central vacuum Systems QUANTITTY pcs Vacuum unit Sistem Test with vacuum gauge 1 Hose connection Universal adapter 1 Test plug Test certificate block in triple copy Bag with handles to transport the kit 1 rif 01 2008 ENG 147 www sistemair it SPARE PARTS SPARE PARTS FOR DOMESTIC SERIES SISTEM AIR spare parts are individually packed TECNO ACTIVA TECNO EVOLUTION GENERATION CENTRAL UNIT SPARE PARTS e Evolution Generation TECNO Activa Generation ART 3107 1 3108 1TE 3109 1TE 3110 1TE 3112 1TE 3113 1TE 3115 1TE 3107 1TA 3108 1TA 3109 1 3110 1TA 3112 1TA 3113 1TA 3115 1TA MODEL MEDIA MEDIA 5 050 SA100 SA200 SA400 MINI MEDIA MEDIA SA050 SA100 SA200 SA 400 TE TE TE TA TA 5 TA TA TA TA ARTICLE Filter cartridge 1610 0 Quantity 1 piece 1610 5
135. or brush 7047 1 ES b Brush for dusting 7043 0 ES 2 Crevice tool 7045 0 MINI kit SD wwwsistemairit rif 01 2008 ENG Full kits KITS AND ACCESSORIES ARTICLE ARTICLE CLEANING ACCESSORIES KIT STANDARD CLEANING ACCESSORIES ELITE 7032 0 7031 0 Qty Qty 7041 0 Accessory holder 10 pieces 7041 0 Accessory holder 10 pieces 6 6 metre hose W U 7 metre hose 7037 7 Wall end swivel connector 7038 0M 2 metre hose Plastic elbow connector 7039 1 Wall end swivel connector 7038 0M EX Pair of chrome pipes 7040 0 Extension pipe connector 7048 0 30 cm floor brush 7047 1 Chrome elbow connector 7039 0 Brush for dusting 7043 0 Chrome telescopic extension 7040 1 7046 0 30 cm floor brush 7047 1 Brush for clothes 7042 0 1 Dual purpose brush 7036 0 Brush for mattresses upholstery 7044 0 Brush for dusting 7043 0 Crevice tool 7045 0 Radiator brush 7046 0 ARTICLE ES 7032 2 Kit wit 9 m hose Brush for clothes 7042 0 1 7044 0 7045 0 ARTCLE STANDARD kit 7031 2 Kit wit 9m hose 133 rif 01 2008 ENG www sistemair it L KITS AND ACCESSORIES Full kits ON OFF Complete cleaning accessories kit 32 mm cleaning accessories kit for rectangular and square mounting plates Cleaning accessory kit suitable for rectangular and square inlet valve
136. ows the installation NB The connection to the piping system for suction and exhaust as well also in houses with reduced foundation The as the electric connection to the micro line and to the power supply specific template makes the pre installation should be done through the template easier because all you need to install the unit is to insert the central unit onto the template itself Thanks to the soundproof material and to the care with which it vacuum unit Sistem CUBE allow the installation was designed and produced Sistem CUBE can be installed both of the same also where the available room is very inside and outside the house The little dimensions of the central reduced rif 01 2008 ENG www sistemair it Sistem CUBE central vacuum unit 54 DOMESTIC WIRING OF THETEMPLATE 1 Wire the connectors of the panel with the cables going out from the template 2 Screw the panel on the template taking of the centring mark Vdc12V V ac 220 240 PERFORMANCE GRAPHIC Vacuum SISTEM CUBE mmH20 ELECTRICAL CONNECTION SISTEM CUBE Sistem CUBE template 4 P Inlet e a V ac 220 240 L N mum 1 5 mm Micro line 12 V dc SA SJ N END Z E f 4 CH A At tan C Wa Q EC AG Sj S W Wo Q Wp 7 Pay NS
137. pipes and connectors 109 www sistemair it i INSTALLATION Electronic control systems ELECTRONIC CONTROL SYSTEMS Remote control electronic systems can be used to control the maintenance of the central unit on Domestic Professional and Industrial series The remote con trol systems for the Tecno series is built with particular emphasis in design It allows you to check out the programmed maintenance required so that the central unit works perfectly The ease with which it is installed allows you to use it on all existing systems in the central vacuum sector and the pre set pro gramming allows you to use it immediately In order to personalise the mainte nance cycles it is possible to intervene on the programming modality foreseen following the instructions found in the user s manual Tecno Control comes in three versions Control Table for use in the reception of a hotel or public building Control Wall for professional use with wall installation The connection and installation are extremely easy as this is done by connecting up to the main electric power network and any micro line point of the vacuum system You can programme the dust container emptying cycles filter cleaning and motor maintenance cycles STANDARD REMOTE CONTROL WALL PANEL COMBINABLE WITH ALL CENTRAL UNIT MODELS ON THE MARKET ARTICLE COLOUR MATERIAL PACKING pcs la nd 65 4200 6 WHITE AND BLACK PLASTIC
138. rd Jolly protection filter for washable motor Jolly box Jolly external box Jolly box extension Jolly set fittings for side discharge Jolly set grates for air discharge Jolly blind box cover Jolly cleaning accessories kit Jolly cleaning accessories kit with 12 m hose Jolly basic set Jolly vacuum unit Jolly vacuum unit contact Jolly decorative frame in grained wood Jolly decorative frame in light carbon Pre wired conduit 2x1mm 50 m Pre wired conduit 2x1mm 100 m Pre wired conduit 2x1mm 25 m Special glue 250 g with brush Special glue 500 g with brush Special glue in a tube 60 g Special glue 500 g without brush Catalogue PAGE 151 151 151 151 44 44 44 44 44 44 44 44 49 43 43 151 151 106 106 106 106 106 106 106 www sistemair it central vacuum systems 159 160 DESCRIPTION OF HOMOLOGATION CERTIFICATION COMPLIANCE WITH REGULATIONS Homologation C Label showing compliance with EU Directives Quality label Confirms that the product was homologated by the Italian Institute for the Quality Label IMQ Quality label Confirms that the product has been homologated 1 by the American certification body NOTE only for central unit N Model SA100TA 110 IP insulation level Insulation level of the apparatus against solid parts and liquid from outside IP 20 Apparatus protected against solid parts larger than 12mm but not protected against the in
139. re parts are individually packed JOLLY SISTEM SPARE PARTS Bags Quantity 5 pieces Motor protection filter Quantity 1 piece Motor Quantity 1 piece Jolly contact electronic board Quantity 1 piece Grained wood coloured decorative frame Quantity 1 piece coloured decorative frame Quantity 1 piece i Light carbon rif 01 2008 ENG JOLLY Serie ART 8710 0 8720 0 MODEL ARTICLE 8402 0 SPARE PARTS central vacuum systems SPARE PARTS FOR PROFESSIONAL SERIES TECNO BLOCK MINI CENTRAL UNIT SPARE PARTS TECNO Block Mini MODEL 131151 31152MB ARTICLE Filter cartridge 1610 1 Quantity 1 piece Bags Quantity 20 pieces 63 air vent silencer 110002 Quantity 1 piece Compressor for 040002 self cleaning lt 3 Quantity 1 piece 2 Solenoid valve for self 040016 cleaning Quantity 1 piece Electronic pressure switch for self cleaning Quantity 1 piece 26 lt gt Electronic board for self cleaning uantity 1 piece Timer for self cleaning 040020 Quantity 1 piece 151 www sistemair it C SPARE PARTS SPARE PARTS FOR PROFESSIONAL SERIES SISTEM AIR spare parts are individually packed TECNO BLOCK MAXI CENTRAL UNIT SPARE PARTS TECNO Block Maxi MODEL 3200 0MB 32001 MB 3200 4MB 3200 6MB 3200 8MB 3200 3MB
140. ribution on each floor The position of the vacuum openings should take into consideration the fact that the hose used for cleaning is 7 metres it is therefore important when positioning the vacuum openings to consider the problems that furniture might cause and not forget to add balconies terraces and other surface areas The central vacuum units should be selected according to the surface area to be cleaned in order to ensure long life and the best performance over time PLAN OF FIRST FLOOR PLAN OF BASEMENT FLOOR AL e STOCK ROOM GARAGE SYSTEMS STOCK ROOM OZ EL 2 STOREROOM P ee GREENHOUSE rif 01 2008 ENG PLAN OF GROUND FLOOR DESCRIPTION 50 mm PVC piping Micro switch line A Inlet valve 9 Upright pipe Central vacuum unit 2 101 www sistemair it ET INSTALLATION Installation materials INSTALLATION Installation area The SISTEM AIR installation material in PVC is suitable for all kinds of central va cuum systems and can be divided into four product categories Grey 50 mm 2 2 mm thick 063 0 80 100mm 3 0 mm thick piping Grey 0 50 mm 2 2 mm thick 063 0 80 100mm 3 0 mm thick connec tors Grey conduit with 2 1 mm2 conductors inserted Special self adhesive glue to join the piping to the connectors Particular characteristics of the product Quality sturdy system products that meet with the strictest saf
141. rif 01 2008 ENG Installation materials TECHNICAL CHARACTERISTICS OF THE INSTALLATION MATERIAL PIPING 50x2 2 mm 2 63x3 mm 2 80 x3 mm 2 100x3 mm PVC piping non plastic polyvinyl chloride PVC U for air suction Self extinguishing piping cat 1 according to material classification in the D M 26 06 1984 Ministerial Degree based on ISO 1182 UNI 8457 test methods Grey Compliance with legislation 50 pipes Specification based on former UNI 7443 1985 FA 178 1987 certification issued by the Italian Institute of Plastics 63 80 100 pipes UNI EN 1329 2000 certification issued by the Italian Institute of Plastics Applied compliance label Piip c 261 The SISTEM AIR rigid piping with circular section is for use on centra lised vacuum systems and for discharge that is not under pressure or compressed ventilation Ideal for glued joints CONNECTORS PVC connectors for air suction The connectors have a calibrated coupling diameter to obtain the best coupling with the piping Available in numerous forms and connections in 50 63 80 100 diameters as well as the numerous accessories Colour grey Self extinguishing Fire resistance level behavioural category according to RSN MI le gislation superior standard quality in the field of plastic fire resistan STEEL PIPES AND CONNECTORS Pipes thickness 2 50x2 mm 2 60x1 8 mm Material PO2 Caracteristics welded and
142. s supplied in single packing N B These models are used when the activation of the system is effected by the use of a micro switch from the handle of the flexible hose ARTICLE ARTICLE CLEANING ACCESSORIES KIT STANDARD CLEANING ACCESSORIES KIT ELITE 7032 1 7031 1 7041 0 7041 0 Accessory holder 10 pieces Accessory holder 10 pieces 7 metre electric hose 7037 4E 7 metre electric hose 7037 4 Pair of chrome pipes 7040 0 Crome telescopic extension 7040 1 30 cm floor brush 7047 1 30 cm floor brush 7047 1 Brush for dusting 7043 0 Radiator brush 7046 0 Brush for clothes 7042 0 Dual purpose brush 7036 0 Brush for dusting 7043 0 Radiator brush 7046 0 Brush for clothes 7042 0 Brush for mattresses upholstery 724776 Crevice tool 7045 0 Brush for mattresses upholstery 72477 Ru ARTICLE 7032 2bE Standard kit with 9 m hose Crevice tool 7045 0 ARTICLE 7031 2E Elite kit with 9 m hose STANDARD kit 134 wwwsistemairit rif 01 2008 ENG Cleaning accessories KITS AND ACCESSORIES CLEANING ACCESSORIES The SISTEM AIR cleaning accessories are supplied in indivi dual packing for specific use in domestic and business en vironments 37 CM FLOOR BRUSH CARPET BEATER BRUSH WITH 12 VOLT BATTERY 2 4 adi 30 CM FLOOR BRUSH 12V BATTERY FOR CARPET BEATER BRUS
143. s MINI 7100 2 Case cover for units MEDIA EXAMPLE OF POSITIONING DIMENSIONS Solution for the installation Solution for the installation of units TA TE Mini of units TE TE Media lt 103 rif 01 2008 ENG www sistemair it INSTALLATION Installation materials INSTALLATION MATERIAL Rigid PVC piping and connectors especially designed for central vacuum sy stems with a view to create a perfect fit between the piping and connectors only 45 connectors are provided to allow for the best air flow possible without creating the possibility of the system blocking NB It is extremely important that the rigid PVC piping is cut using the appropriate tool pipe cutter and that the hold between the joints is guaranteed by using the special SISTEM AIR glue in abundance spreading it on the male and never on the female connector PVC PIPING DESCRIPTION PACKING m 1850 0 50 2 2 mm thick PVC PIPE 2 m bars 1863 0 63 mm thick PVC PIPE 2 m bars 1880 0 80 3 mm thick PVC PIPE 2 m bars 1810 0 100 3 mm thick PVC PIPE 2 m bars PVC 45 ELBOW 3050 0 50 45 male female PVC elbow 3063 0 63 45 male female PVC elbow 100 45 male female PVC elbow 50 45 female female PVC elbow 63 45 female female PVC elbow 80 45 female female PVC elbow PVC 45 DERIVATION ARTICLE DESCRIPTION PACKING pcs 4050 0 50 45 male female
144. t is in fact possible to invert the motors start up priority using a cyclical switch thus balancing out the motors state of wear ARTICLE MAX MOTORS POWER SUPPLY Volt ac PACKAGING pieces A FOR MOTOR Article 330 3301 10 CONTROL PANEL FOR THE MODULATION OF THE MOTOR SPEED The electronic panel for the modulation of the speed of the motor body is used when you one electronic motor is installed The internal electronic system al lows for the installation on the micro switch line using the resistive divider parts no 3301 4 to control the speed of the motor body according to the number of inlet valves used and to obtain greater performance with lower consumption The system foresees up to four levels of commutation 4 speeds and is suitable for all the electronic units even those with different power ARTICLE MAX MOTORS POWER SUPPLY VOLT AC PACKAGING pieces FOR MOTOR Article 3301 5 220 240 220 240 83 rif 01 2008 ENG www sistemair it INDUSTRIAL Dust Separators Blowing Power Units Range Peripherals of central units RETENTION VALVES FOR MOTOR COUPLING If there is more than one blowing unit on the same system the retention valve has to be fitted on each individual motor It has to be installed directly on the motor air vent connector to ensure the maintenance of the air pocket when one motor is in use whi
145. tem The separator s particular construction aspects means it has two separate openings one on the right the other on the left to connect to the sy stem s vacuum piping and air discharge In the event of a system on several floors it should be installed on the bottom floor www sistemair it Dust Separators Blowing Power Units Range Peripherals of central units a LT 80 LT 80 C A INSTALLATION AREA The 80 litre and 160 litre dust separators are available in versions with or without self cleaning They have to be used in conjunction with one or more vacuum motors with configured systems for air flow up to 700 m h for the 80 litre ver sion and up to 1200 m h for the 160 litre version These parts are used for sy stems with the following characteristics Piping network with main duct in the floor and 50 and 63 mm diameter hose 63 80 mm upright pipe for the 80 litre version or 63 80 100 mm for the 160 litre version depending on the selected configuration 80mm dust inlet 80 litres or 100 mm 160 litres 220 240 V single phase power only on models with self cleaning Discharge to the outside Possibility of 4 operators using the 80 litre system simultaneously or 6 opera tors using the 160 litre one PARTICULAR CHARACTERISTICS OF THE PRODUCT Dust container that holds 80 litres for the 80 litre unit and 160 litres for the 160 litre one Front handle to easily unhook the dust contain
146. th for the deri vation of a socket pipe line on the same floor and for the stable implementation of upright pipes on several floors It is essential that the derivation is always installed Direction of suction correctly in relation to the system s direction of suction see figure The incorrect installation of the derivation will inevitably block the system o the central vacuum unit CORRECT Installation Special situations During installation you may encounter obstacles that cannot be overcomed be cause the foundation is not properly levelled this problem can be resolved with a so called underground passage The underground passage should be done with a male female 45 curve connector a female female 45 connector a small piece of pipe another male female 45 elbow connector and another female female 45 elbow connector This operation should be carried out as few times as possible on the same system as it would produce a considerable strain on the C O speed of the vacuumed air CORRECT Installation Expansion joint Under system conditions like those shown in the figure below attention should fo cus on expansion of the ground SISTEM AIR resolves this problem by using special expansion joints see chapter on Installation to be installed one right at the outlet of the piping in the first structure and a second one before the inlet of the second structure The piping located in the ground should be insulated in order to re
147. that there is no need to tran sport the flexible hose Furthermore the work is made easier by the fact that it is possible to use only the length of hose required All the reels are supplied with the flexible hose in stalled REEL TROLLEY The reel trolley is fitted with a trolley for carrying accessories to make it easier to carry the material and to have the clea ning accessories always close to hand Link up to the piping network is done using any kind of inlet valve on the vacuum system FLEXIBLE START UP EU PACKING ARTICLE HOSE MM CONTACT E 032 WALL MOUNTED REEL The wall mounted reel is fitted with an electric start up con tact and automatic hose rewinding The electric connection is made using a link up to the systems micro line with a sim ple inlet valve The connection to the piping network does not require any particular inlet valve but is done directly by fixing a 50 hose connector to the piping in the piping net work 50 The movement of the guiding arm and hose unwinding will activate the central vacuum unit and will be deactivated when the arm is back to the closed position rif 01 2008 ENG SIZES AND USE 1000 LIY 850 450 620 2 4 FLEXIBL
148. the left to connect to the system s suction piping and air discharge Option of multiple installation with several separators linked to each other ONLY FOR MODELS WITH SELF CLEANING 220 240 V ac general power Magnet thermal protection switch on the control panel Self cleaning programming timer Air compressor Noise level of compressor 68 dB A Programmable self cleaning to clean the filter cartridge The system comes with a compressor and storage cylinder 20 litres for the compressed air that is discharged into the filter at programmable intervals rif 01 2008 ENG INDUSTRIAL central vacuum Systems Solenoid valve only for separators with self cleaning 2 Safety valve for vacuuming 3 Manometer only for separators with self cleaning E Compressed air tank only for separators with self cleaning 5 Control panel only for separators with self cleaning 6 Compressor only for separators with self cleaning 7 Base 8 Cover 9 Impeller for self cleaning only for separators with self cleaning 10 Dust separator compartment 11 Unhooking handle 12 Filter cartridge 13 Conveyor cone 14 Handle 15 Dust container 16 Dust bag 17 Bag string 18 Wheels 19 Air vacuum attachment for the blowing power unit 20 Dust inlet 71 www sistemair it kak 72 INDUSTRIAL Dust Separators Blowing Power Units Range Peripherals of
149. tronic card for TECNO STAR spare parts Electronic board for computer Wolly soft start system Motor for SA400TA central unit Motor for MEDIA PLUS central unit Motor for TECNO STAR Motor for Wolly Motor for SA050 0TA www sistemair it Catalogue PAGE 120 126 125 125 128 125 128 128 119 119 HS 124 124 127 124 124 128 123 106 125 124 124 124 124 123 123 123 124 124 124 125 123 125 23 123 148 151 150 152 148 148 150 150 148 148 150 149 149 149 149 149 150 149 148 150 150 150 149 149 150 150 149 157 Ss 158 ARTICLES CONTENTS ARTICLE DESCRIPTION 1613 8 Motor for SA100TA TE 1613 9 Motor for SA200TA 16142 Dust bags for separator LT80 and Tecno Block Mini 1614 3 Dust bags for separator LT 160 pcs 20 1614 4 Universal bag and bag tightener housing line pcs 10 1614 15 Bags for Sistem Cube 1623 10 Motor for SA400 TA TE Generation 1623 11 Motor for Media Plus TA TE Generation 1623 7 Motor for MIni Media SA50 TA TE Generation 1623 8 Motor for SA100 TA TE Generation 1623 9 Motor for SA200 TA TE Generation 1623 15 Motor for Sistem Cube 1810 0 PVC pipe 3m thick 2 m bars 100 1850 0 PVC pipe 2 2m thick 2 m bars 50 1850 0F Steel pipe 50mm 1850 0A Aluminium alloy pipe 3 m 50 1863 0 PVC pipe 3 mm thick 2 m bars 63 1863 0A Aluminium alloy pipe 3m 6060 63 1863 0F Steel pipe 60 mm 1880 0 PVC pipe 3mm thick 2 m bars 80 2050 0
150. ures simple installation and a perfect hold of the inlet valve N B Each extension kit is fitted with 3 1cm frames a 3cm inlet valve extension and a pack of screws accordingly Kits can be added until you have the measurement required T i 3 CM EXTENSION C ARTICLE DESCRIPTION PACKING PIECES 1457 1 Extension for domestic inlet valves 3 CM EXTENSION KIT ARTICLE DESCRIPTION PACKING PIECES 1450 8 Extension kit for rectangular mounting plate 10 Kit 3 CM EXTENSION KIT ARTICLE DESCRIPTION PACKING PIECES 1450 9 Extension kit for square mounting plate 10 kit 120 SD wwwsistemairit rif 01 2008 ENG 121 central vacuum systems MOUNT PLATES AND INLET VALVES DRAWING Extension kits www sistemair it rif 01 2008 ENG MOUNT PLATES AND INLET VALVES Inlet valves INLET VALVES FOR THE DOMESTIC RANGE The SISTEM AIR inlet valves meet all requirements and aesthetic needs all the inlet valves for rectangular boxes have to be accompanied by a decorative pla que for the domestic range that they refer to while the inlet valves for square boxes already come with an aesthetic finishing in two different colours N B The inlet valves for the rectangular box are universal and permit to activate deactivate the central vacuum unit by inserting th
151. urity 6 Sonda termica di sicurezza 7 Motor 8 Cover motor 9 Electronic board 10 Pins centering 11 Dust inlet 12 Gasket 13 Holes centering 14 Micro connector line 15 Power connector 16 Air vent 17 Electrical box 33 rif 01 2008 ENG www sistemair it DOMESTIC FIXING OF THE UNIT The central unit Sistem CUBE is to be inserted in the special template art 8300 10 which was first wired While inserting the unit it is important to make the centring pivots correspond with the holes on the unit and on the template TABLE OF MEASURES AND TECHNICAL DATA ART 8300 0 MODEL Sistem CUBE Maximum number of operators un rn et 3 C UJ rri Maximum surface 120 Number taken recommended Supply 220 240 50 60 Frequency Motor power KW Sistem CUBE central vacuum unit Absorption Ampere 4 5 Maximum capacity 178 Supply sockets Volt 12 Filter security YES Dust container capacity Liter 5 Weight Kg 4 Width mm 290 Height mm 310 depth mm 290 Vacuum attachment mm Unloading attack o mm N B Levels of nominal noise The levels can vary according to the speed of use environment where the central unit has been installed and the kind of installation 34 www sistemair it
152. with the following regulations EN 60335 2 2 2003 A1 2004 A2 2006 EN 60335 1 2002 A11 2004 A1 2004 A12 2006 A2 2006 EN 50366 2003 A1 2006 PROFESSIONAL SECTOR Series TECNO Block Mini Maxi Apparatus complies with the following regulations 98 37 CEE Machine directives former 89 392 CEE and later changes 73 23 CEE Low Voltage Directive and later changes 89 336 CEE Electromagnetic compatibility directive and later changes INDUSTRIAL SECTOR Apparatus complies with the following regulations 98 37 CEE Machine directives former 89 392 CEE and later changes 73 23 CEE Low Voltage Directive and later changes 89 336 CEE Electromagnetic compatibility directive and later changes N B As far as the installation stage is concerned stick rigidly to what is laid down in current legislation N B All measures are indicated in mm www sistemair it rif 01 2008 ENG WWVW SIstemalr It A vIvIGO AIR CENTRAL VACUUM SYSTEMS 27020 Gravellona PV ITALIA Cilavegna 53 Tel 39 0381 650082 Fax 39 0381 650120 info sistemair it
Download Pdf Manuals
Related Search
Related Contents
UV-LED光源を安全にご利用頂くために【旧規格】 Manuel d`utilisation VISCO 500 Philips 26HFL3350D/10 Flat Panel Television User Manual Copyright © All rights reserved.
Failed to retrieve file