Home

Manual - Stabila

image

Contents

1. Laser Distancer LD 400 My viiavis Operating instr ictions SPIDPUDIS 57 IA m 8 1 im ZE HE SE eS IN no oo a C een mt to 20 e 004 00 0 11 MA ao o o e 00 Oo Qc ENE E Ta o am pa o E uh 2 lt 13 12 Complies with 21 CFR 1040 10 and 1040 11 except for deviations pursuant to Laser Notice No 50 dated July 26 2001 AW OCE Stabila Messgerate D 76855 Annweiler am Trifels Type LD 400 PIN 17263 Power 2 x AAA Made in Hungary A User Manual English Congratulations on the purchase of your Stabila LD 400 The safety instructions and the user A N manual should be read through carefully before you use the product for the first time The person responsible for the product must ensure that all users understand these directions and adhere to them Symbols used in this manual The symbols used have the following meaning WARNING Indicates a potentially hazardous situation or an unintended use which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation or an unintended use which if not avoided may result in minor injury and or in appreciable material finan cial and environmental damage Important paragraphs which must be adhered to in practice as they enable the product to be
2. or off Reference Setting Default reference setting is from the rear of the instrument The instrument can be set for the following measure ments e To measure from an edge see drawing D fold out the stop bracket until it snaps in for the first time See drawing E To measure out of a corner see drawing D fold out the stop bracket until it snaps in push Stabila LD 400 the stop bracket with a little force to the right side the stop bracket can now be completely unfolded See drawing E A CAUTION Make sure that when measuring from the unfolded endpiece the measuring reference is set to End piece as 1x briefly the next measurement is taken from the front edge EN 2x briefly the measurement is taken from the unfolded end piece After one measurement the reference returns auto matically to the default setting rear reference EX 1x long the measurements are taken with the front as reference until a new measuring refe rence is set gj 2x long the measurements are taken from the unfolded end piece until a new measuring refe rence is set See drawing F Measuring ms Single Distance Measurement El 1x briefly the laser is activated O 1x briefly a distance measurement is taken The result is displayed immediately Continuous measurement Distances can be measured with this function O 1x long a beep is sounded A continuous measurement is started The last measur
3. Stabila LD 400 Timer self triggering Appendix 1x long The symbol is displayed lt lt lt The timer is preset to 5 seconds Display Notices The value is increased All display notices are either displayed with or Error The following errors can be corrected Holding the buttons down increases the rate of change of the values Cause Correction The countdown starts automatically if the laser is 204 Calculation error Repeat procedure activated and then triggers the measurement 252 Temperature too Let device cool down n high Switching off the beep 253 Temperature too Warm device up ow K Press and hold simultaneously for 255 Received signal too Use a target plate weak time for a measurement too The beep is switched off 5 ong i To reactivate it press and hold for 5 seconds 56 Received signal too Use target plate gray 5 seconds strong side 257 Faulty measure Use target plate brown ment too much side background light 258 Outside of the range Select measurement of measurement distance within the range of measurement Error Cause Correction Error Hardware error Should this message remain active after switching the instru ment off and on several times please contact the dealerhip Stabila LD 400 E gay al Appendix Technical Specifications Range 0 05 m to 60 m Measuring accuracy 2 o ty
4. end piece Pythagoras Timer self triggering Historical memory Area volume Battery status Units with exponents 2 3 Intermediate line 2 10 Intermediate line 1 11 Main targets 12 min max display 13 Info symbol Start up Inserting Replacing Batteries 1 Remove battery compartment lid See drawing C 2 Insert batteries observing correct polarity 3 Close the battery compartment Replace the batteries when the symbol il flashes permanently in the display 4 Only use alkaline batteries CE Ifthe instrument will not be used for a long time remove the batteries as a protection against corrosion OMONAOUNRWNEH Stabila LD 400 Measuring Conditions Range Range is limited to 60 m At night or dusk and if the target is in shadow the measuring range without target plate is increased Use a target plate to increase the measurement range during daylight or if the target has poor reflec tion properties Target Surfaces CAUTION Measuring errors can occur when measuring toward colourless liquids e g water or dust free glass Styrofoam or similar semi permeable surfaces Aiming at high gloss surfaces may deflect the laser beam and lead to measurement errors Hazards of Use CAUTION Watch out for erroneous distance measure ments if the instrument is defective or if it has been dropped or has been misused or modified Precautions Carry out periodic test measurements Particularly
5. first measurement and the distance to be measured are at right angles Use the minimum maximum function Indirect measurement determining a distance using 2 auxilliary measurements See drawing G LA 1x briefly the IS symbol is displayed The distance to be measured flashes in the symbol O 1x briefly takes a measurement of the distance Stabila LD 400 Pea cee Functions The second distance to be measured flashes in the symbol 1x briefly takes a measurement of the hori zontal distance The result of the function is displayed in the summary row If the O button is pressed for along time while measuring a distance maximum or minimum conti nuous measuring is activated Indirect measurement determining a distance using 3 auxilliary measurements See drawing H symbol is displayed The distance to be measured flashes in the symbol 0 1x briefly takes a distance measuement The second distance to be measured flashes in the symbol 1x briefly takes a horizontal measurement The third distance to be measured flashes in the symbol O 1x briefly takes a measurement of the distance The result of the function is displayed in the summary row If the O button is pressed for along time while measuring a distance maximum or minimum conti nuous measuring is activated Stake out function This function is helpful when staking out equal distances e g in the erection of wooden substruc tures See drawing
6. I 1x briefly the 4 symbol is displayed A value is displayed in the summary row default value 1 000 m This value can be adjusted to the desired stake out distance E me value is increased i y The value is reduced Holding the button down accelerates the speed at which the value changes O 1x briefly starts continuous measurement In intermediate line 1 the set distance or the next appropriate multiple thereof is displayed In the summary row the distance to the next appro priate stake out point is displayed When approaching a stakeout point to less than 0 10 m the instrument starts to beep When the point is reached the beep sound changes and inter mediate line 1 starts to flash 1x briefly distance measurement is interrupted and the instrument switches back to individual distance measuring mode Functions Historical memory 1x briefly the tJ symbol and the last measured value are displayed Use to navigate through the last 10 values The values can also be used in functions Using stored values in functions Using added distances in area functions e g wall surfaces or painters Adding distances see additions subtractions Call up area function to e g measure the height of a room 1x briefly calls up the historical memory and to possibly search for the correct value 1x long the value is entered into the function and the result of the function e g area is displayed
7. a completely safe condition Responsibilities of the manufacturer of non Stabila accessories The manufacturers of non Stabila accessories for the Stabila LD 400 are responsible for developing imple menting and communicating safety concepts for their products They are also responsible for the effecti veness of these safety concepts in combination with the Stabila equipment Responsibilities of the person in charge of the instrument A WARNING The person responsible for the instrument must ensure that the equipment is used in accor dance with the instructions This person is also accountable for the deployment of personnel and for Overview their training and for the safety of the equipment when in use The person in charge of the product has the following duties To understand the safety instructions on the product and the instructions in the user manual To be familiar with local safety regulations rela ting to accident prevention e To inform Stabila immediately if the equipment becomes unsafe Keyboard See drawing A 1 ON ON MEAS button 2 AREA function button 3 STAKE OUT function button 4 PLUS MINUS button 5 HISTORICAL MEMORY TIMER button 6 CLEAR OFF button 7 PHYTAGORAS indirect measurement button 8 ILLUMINATION UNITS button 9 REFERENCE button 10 VOLUME function button Stabila LD 400 Display See drawing B Laser ON Reference front rear
8. after the instrument has been subject to Start up abnormal use and before during and after important measurements Make sure the Stabila LD 400 optic is kept clean and that there is no mechanical damage to the bumpers CAUTION In using the instrument for distance measure ments or for positioning moving objects e g cranes building equipment platforms etc unforeseen events may cause erroneous measurements Precautions Only use this product as a measuring sensor not as a control device Your system must be configured and operated in such a way that in case of an erroneous measurement malfunction of the device or power failure due to installed safety measures e g safety limit switch it is assured that no damage will occur Switching on off O 1x briefly the instrument and the laser are swit ched on The display shows the battery symbol il unti the next button is pressed Pressing this button for longer switches the instrument off The instrument switches off automatically after three minutes of inactivity Operation Setting the instrument Press long until the desired unit is displayed Possible units Distance Area Volume 1 0 000 m 0 000 m 0 000 m 2 o o he 0 00 ft 0 00 ft 3 O in 1 16 0 00 ft 0 00 ft 4 0 00 ft 0 00 ft 0 00 ft CLEAR Key 1x briefly the last action is cancelled Illumination 1x briefly the display illumination is switched on
9. de Appendix Disposal A CAUTION Flat batteries must not be disposed of with household waste Care for the environment and take them to the collection points provided in accordance with national or local regulations The product must not be disposed with household waste Dispose of the product appropriately in accordance with the national regulations in force in your country Adhere to the national and country specific regula tions All right reserved for changes drawings descriptions and technical specifications Appendix iZ E Te Stabila LD 400
10. ed value is displayed in the summary line 1x briefly the continuous measurement is stopped Minimum Maximum Measuring This function enables determining the minimum or maximum distance from a specific measuring point e g the determination of room diagonals maximum value or horizontal distance minimum value Switching on continuous measurement see above The corresponding maximum and minimum values are displayed Stabila LD 400 o GES Ti Measuring Addition Subtraction Distance Measurement 1x briefly the next measurement is added to the previous one 4 2x briefly the next measurement is subtracted from the previous one Repeat this procedure for as many times as required The result is displayed in the summary row the previously measured value is displayed in interme diate line 2 the value to be added in intermediate line 1 1x briefly the last step is cancelled Area function 1x briefly The 4 amp symbol is displayed 1x briefly takes first distance measurement e g length 1x briefly takes second distance measurement e g width The result of the area measurement is displayed in the summary row the individually measured values are displayed in intermediate lines 1 and 2 Functions Adding and subtracting areas Calling up the area function and measuring areas Press 1x or 2x 1x briefly takes first distance measurement e g length 1x briefly takes second dista
11. nce measurement e g width The result of the second area measurement flashes 1x briefly confirms the addition the added area results are displayed in the summary row Volume function 5 1x briefly the g symbol is displayed 1x briefly takes first distance measurement e g length 1x briefly takes second distance measurement e g width The result of the area measurement from the values already measured is displayed in the summary row 1x briefly takes the third distance measure ment e g height The value is displayed in intermediate line 1 The result of the area measurement is displayed in the summary row the two previously measured Stabila LD 400 values in intermediate lines 1 and 2 Indirect Measurement The instrument can measure distances with the Pythagorean method This procedure facilitates in measuring distances that are difficult to access CE Adhere to the prescribed sequence of measu rements All target points must be vertical or horizontal on the surface of the wall The best results are achieved when the intrument is rotated around a fixed point e g the stop bracket is fully extended and the instrument is placed against a wall e To take the measurement the minimum maximum function can be called up The minimum value is used for measurements that must be at right angles to the target the maximum distance is used for all other measurements Make sure that the
12. pically 1 5 mm Smallest unit displayed 1 mm Laser class 2 Laser type 635 nm lt 1 mW Protection against splashes and dust IP 54 dust proof splash proof Autom power off Laser after 60 s Instrument after 180 s Illumination Y Folding out endpiece Y Battery life up to Type 2 x AAA 5 000 measurements Dimension 113 x 50 x 25 mm Weight 1108 Temperature range Storage 25 C to 70 C Operation O C to 40 C Use a target plate to increase the measurement range Electromagnetic Compatibility EMC The term electromagnetic compatibility is taken to mean the capability of the product to function smoothly in an environment where electromagnetic radiation and electrostatic discharges are present and without causing electromagnetic interference to other equipment A WARNING The Stabila LD 400 conforms to the most strin gent requirements of the relevant standards and regulations Yet the possibility of the product causing interfe rence in other equipment cannot be fully excluded during daylight or if the target has poor reflection properties in favourable conditions good target surface properties room temperature up to 10 m In unfavourable conditions such as intense sunshine poorly reflecting target surface or high temperature variations the deviation over distances above 10 m can increase by 0 15 mm m Appendix a Stabila LD 400 La
13. ser classification The Stabila LD 400 produces a visible laser beam which emerges from the front of the instrument See drawing K The product is a Class 2 Laser Product in accordance with e 1EC60825 1 2007 Radiation safety of laser products Class 2 Laser Products Do not stare into the beam or direct it unnecessarily at other persons Eye protection is normally afforded by aversion responses including the blink reflex WARNING Looking directly into the laser beam with optical aids e g binoculars telescopes can be hazardous Precautions Do not look directly into the beam with optical aids CAUTION Looking into the laser beam may be hazardous to the eyes Precautions Do not stare into beam Do not look into the laser beam Make sure the laser is aimed above or below eye level particularly with fixed installations in machines etc Stabila LD 400 Labelling Laser Radiation Do not stare into the beam Laser class 2 acc IEC 60825 1 2007 lt 1mw Emitted wavelength 620 690nm Beam divergence 0 16 x 0 6 mrad Impulse duration 1x10 s For the position of the type plate see drawing J Maximum radiant power Care Wipe off dirt with a damp soft cloth Do not immerse the instrument in water Do not use aggressive cleaning agents or solutions Warranty The Stabila LD 400 comes with a two year warranty from Stabila More detailed information can be found at www stabila
14. used in a technically correct and efficient manner Stabila LD 400 Intended Use Permitted uses e Measuring distances Computing functions e g areas and volumes Adverse uses e Using the instrument without instructions e Using outside the stated limits e Deactivation of safety systems and removal of explanatory and hazard labels Opening of the equipment by using tools screwdrivers etc e Carrying out modification or conversion of the product e Use of accessories from other manufacturers without the express approval of Stabila Deliberate or irresponsible behaviour on scaffol ding when using ladders when measuring near machines which are running or near parts of machines or installations which are unprotected e Aiming directly into the sun e Deliberate dazzling of third parties even in the dark e Inadequate safeguards at the surveying site e g when measuring on roads construction sites etc Symbols used in this manual Limits of use CE Also see section Technical data The Stabila LD 400 is designed for use in areas permanently habitable by humans do not use the product in explosion hazardous areas or in aggressive environments Responsibilities Responsibilities of the manufacturer of the original equipment Stabila Messger te D 76855 Annweiler am Trifels for short Stabila Stabila is responsible for supplying the product inclu ding the User Manual and original accessories in

Download Pdf Manuals

image

Related Search

Related Contents

NOT ECHPE ind E 1210 FR  Notice technique  A União  MS-20 mini Owner`s manual  Spirit FOLIO SX mixer User's Manual  Samsung 460UT-2 Vartotojo vadovas  Série MS6000 Osciloscópio de Armazenamento Digital  Translated FUTURA ECO with E27 user guide -GS  Flex Network 2ch Analog Unit User Manual  Limit L15 Pro  

Copyright © All rights reserved.
Failed to retrieve file