Home

SEBURY

image

Contents

1. BC 3100 amp BC 3000 Digital Keypad Introduction The BC 3100 amp BC 3000 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary timed or latching dry contact closure All programming is done through the keypad Codes and operating parameters are stored within the microprocessor and can not be lost due to power failure The BC 3100 has 1 master and can store 100 user 6 digit codes the BC 3000 can store 500 prox cards and user 4 digit codes Each 4 digit code has 10 000 possible combinations The unit has one relay with 5 Amp contacts CONTENTS Page NOGUCH M asza Soe nhac obtained O seems wi 2 PIOCUCESPECIICAUO S Ais anas aus cucu aa is 3 Mounting amp PCB Diagram wo a ey ee ee eat ed eee 4 WING DIAQKANY lt issamesne aes ia eras des tweens as kas 4 5 Engineer Programming Information and Notes 5 Engineer Programming Factory Default Setting iscsi vers Isa a iais ai o a a KE 6 Changing Master amp User Codes ccccececeeeeeeeeeeeeneenes 7 Setting Functions of Master 8 User aaa 7 Sel Door REYS MKE eec EA sock ais 7 Set Door Open Detection Time kaka aaa 8 SEGUNIYATANJEME I Likti ski aa a isalas 9 Exit Engineer Programming Mode aaa aaa 9 Resetting Non Volatile Memory uaaaa aaa aaa eeaeeeneenaeeees 9 Installer Information amp Notes aaa aaa kaka aaa aaa aaa 9 Technical SPeCwICAlONS L 2 tine ki a
2. not be saved Changing Master amp User Codes BC 3100 amp BC 3000 In engineer programming mode To change Master code Press 0 Ei E Upon acceptance Open LED illuminates and stops flashing Press after changing the master code otherwise unit will disregard the new code and revert back to the factory default code Note the master code must be 4 8 digit number Adding User Codes BC 3100 To Add User and User Codes BC 3100 Press 1 user code user identification Note the user identification must be 3 digit number within 000 999 and the user door release must be 6 digit code Adding User Codes amp Cards BC 3000 To Add User cards amp codes BC 3000 Press 1 E Note the user identification must be 3 digit number if adding more than 1 card read the next card after inputting the 3 digit code for the previous card when you have finished adding all cards press the EJ key 1 card must be 000 up to 999 Then the BC 3000 control station added a user card it was auto added a user code with 1234 Delete User Code BC 3100 There are 3 options to delete a user card or cards in engineering mode a Press 2 0000 to delete all user codes b Press 2 to delete used this door release code of all users c Press 2 user identification number to delete individual user Then press again to exit engineer programming Delete User Card or Cards BC 3000 There are 3 o
3. a a a a LS 10 Specifications 1 Programmable Functions Relay latching or momentary Relay activate independenily or together Change Codes 1 master 100 users BC 3100 Change Codes 1 master 500 users amp prox cards BC 3000 Door open detection 2 Programmable Timers Door relay time 00 99 seconds Door open detection 00 99 seconds Alarm time 00 99 minutes 3 Wiring Connections Electric lock External bell External Push Switch Magnetic Contacts Alarm 4 Keypad 13 keys bell button 5 Programming memory Non volatile Eeprom memory IMPORTANT INFORAMTION There are no user serviceable parts contained within the BC 3100 amp BC 3000 access control keypad It holes are to be drilled before mounting onto a wall check for hidden cables and or pipes before drilling Use safety goggles when drilling or hammering in cable clips Every effort has been made to provide accurate information however slight variations can occur We also reserve the right to make changes for product improvement at any time NOTE PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL THE BC 3000 BC 3100 1 Attach the rear plate to a single or double gang electrical box or secure to the wall firmly with at least three flat head screws 2 When wiring has been completed attach the front cover to the rear plate Figuret Figure 2 Wiring Cable Hamess Tamper Switch NVM Reset Pins The front cover can be permanently secur
4. e the door Press user passoword Technical Specification DC Supply Voltage Current Consumption Door Relay Tamper Protection Codes BC 3100 Codes BC 3000 Keypad Card Types Induction Distance Wiring Connections Memory Operating Temperature Keypad Housing Dimensions Weight Low voltage input 9 14Vdc unregulated 100mA quiescent maximum bAmp 12Vdc Negative loop normally closed 1 Master 100 codes 1 Master 1000 cards and 1000 codes 12 keys 1 bell push button 3 LED status indicators EM or EM compatible BC 3000 5 15cm BC 3000 Electric lock Remote door control Door open detection External door bell External Alarm Non volatile eeprom memory 0 C to 60 C 32 F to 140 F ABS high impact plastic 120mm x 115mm x 23mm 175g Package Listing Digital Keypad BC 3100 BC 3000 Self Tapping Screws 2 6mmx7 5 mm Screws Used for front case and back case Pastern Stopper 6mmx27 mm Used for fixing
5. ed by using the short screw supplied BC 3100 amp BC 3000 Printed Circuit Board 1 Unplug the cable harness and connect the necessary cables See Figure 3 2 Tape any wires that are unused 3 Plug the cable harness See Figure 2 4 Attach the front cover See Figure 1 Terminal Wire Connector 1 Function gt Z o O S o o 10 Bell1 White Bell Push Button COM Orange Door Strike Relay Com NC Green Door Strike Relay N C Brown To Door Contact Then To Door In 2 OPEN Yellow To Door Remote Control Button Then Negative 1 ALARM Grey Alarm 6 5 NO Blue Door Strike Relay N O 4 3 DO NOT PLUG ADAPTOR OUR TRANSFORMER INTO MAINS UNTIL ALL WIRING HAS BEEN COMPLETED AND THE FRONT COVER SECURED Wiring Diagram Electronic Door Release Holder Hookup 12VDC POWER SUPPLY 10 WHITE CND 12V 9 i 8 RED 7 BLACK 6 ORANGE 5 BLUE t r 4 GREEN i 00000000 3 BROWN o o ss m m m m m m m mi 2 YELLOW o o 1 GREY 12 1 After all wiring is complete and the unit face plate is attached to the back plate apply 12Vdc power to the unit Ready LED illuminated and accept LED flashing Engineer Programming Mode BC 3100 8 BC 3000 To enter programming mode Press 9999 within 5 seconds Ready and Accept LED illuminated Open LED flashing Note Press 4 to save changes and exit engineer programming when all programming has been completed otherwise changes will
6. ptions to delete a user card or cards in engineering mode a Press 0 000 l to delete all user cards b Press read card to delete individual user card c Press user identification number to delete individual user card User Operation Mode BC 3000 There are 3 different options for user operation mode card only card and password valid code The optioned used is common to all users Press 100 valid card only Press 101 valid card and password Press 10 2 valid card or password Setting Door Relay Strike Time The door relay output can be operated as either normally opened or normally closed a maximum current of 10 ampere can pass through the relay if used as normally opened or 5 ampere if normally closed The door relay time can be set from 0 seconds to a maximum of 99 seconds The factory default setting is 6 seconds and can be changed through the keypad Press 4 E Press 5 E Press eeo to disable this function factory setting Press 6 01 to enable this function In order for this feature to work door contacts must be connected There are 2 programming functions that work together in this mode a If door not closed after opening keypad buzzer sounds b If door forced open keypad buzzer sounds and sends alarm signal Setting Security Arrangement BC 3100 There are two levels of keypad security available for the BC 3100 Press entered 4 wrong pa
7. sswords in succession the keypad is locked for 10 minutes Press entered 4 wrong passwords in succession the keypad activates and alarm signal To disable this feature Press factory default setting Setting Security Arrangement BC 3000 There are two levels of keypad security available for the BC 3000 Press to read 10 invalid cards or valid cards then enter 4 wrong passwords in succession the keypad is locked for 10 minutes Press to read 10 invalid cards or valid cards then enter 4 wrong passwords in succession the keypad activates and alarm signal To disable this feature Press factory default setting Resetting To Factory Default Setting To revert all settings to the factory default values then the Non Volatile Memory Eeprom must be reset Reset Non Volatile Memory by switching of the power and placing the jumper connector onto the pins 1 amp 2 as per figure 2 After switching power on remove jumper the BC 3000 will give a beep and is now reset to factory default values Changing User Password Code BC 3100 Press user passoword user identification number d Changing User Password Code BC 3000 The factory default setting for each user password code 1234 this can be modified so that each user has a unique individual 4 digit code Press read user card user passoword new password re enter new password OO Using Password Code to releas

Download Pdf Manuals

image

Related Search

SEBURY sebury keypad sebury keypad manual sebury access control sebury bc 2000 sebury w3-a keypad sebury w1-a keypad sebury w2 sebury w4 sebury 007 sebury k4 manual seabury hall maui

Related Contents

  1746-6.16, Thermocouple/mV Isolated Input Module User Manual  PROSCAN    FeaInformation  Jabra CLEAR  