1. www smith root com 7 1601 Fish Counter Description of Controls and Indicators AE SENSITIVITY TUNNEL py A EN RED LOW BATTERY TEST SR 1601 POWER SUPPLY _ aw EXTERNAL POWER Lie a Power Switch Controls the DC power to operate the fish counter electronics The DC may be supplied from the internal battery from an external 12 Volt DC source or from the internal AC powered DC supply This switch does not control the AC power to the battery charger circuit The battery charger charges the internal 12V batteries only Battery Test Switch And Indicator Press and hold the switch for 30 seconds If the indicator stays green during this time the battery is OK If the indicator turns red or stays red during this time the battery needs to be recharged The internal battery will run the fish counter for 4 days depending on water conductivity 8 www smith root com 1601 Fish Counter Sensitivity The sensitivity control allows the user to set the size of the smallest fish that the fish counter will sense Turning the control clockwise allows smaller fish to be detected Count Switch When in the OFF position all inputs to the counter are disabled This prevents the accumulation of any erroneous counts while moving the count head from rearing pond to rearing pond For normal operation the switch should be in the ON position AC Power Connector and Indicator Lamp Lights up w
2. Product has been subjected to abnormal use abnormal conditions improper storage exposure to moisture or dampness unauthorized modifications unauthorized connections unauthorized repair misuse neglect abuse accident alteration improper installation or other acts which are not the fault of Smith Root Inc including damage caused by shipping b The product havs been damaged from external causes such as collision with an object or from fire flooding sand dirt windstorm lightening earthquake or damage from exposure to weather conditions an Act of God or battery leakage theft blown fuse or improper use of any electrical source or damage caused by the connection to other products not recommended for interconnection by Smith Root Inc c Smith Root Inc was not advised in writing by the Consumer of the alleged defect or malfunction of the Product within fifteen 15 days after the expiration of the applicable limited warranty period d The Product serial number plate or the accessory data code has been removed defaced or altered 7 If a problem develops during the limited warranty period the Consumer shall take the following step by step procedure a The Consumer shall return the Product to Smith Root Inc for repair or replacement processing b The Consumer contacts the Customer Service Department at Smith Root Inc at the number listed on the bottom of this page for repair or replacement processing c The Consumer shall ship t
3. Since 1964 the leader in effective safe and reliable products for fisheries conservation Knowledgeable biologists depend upon Smith Root equipment USER S MANUAL 1601 FISH COUNTER 14014 NE Salmon Creek Ave Vancouver WA 98686 Phone 360 573 0202 Fax 360 573 2064 07289 01 www smith root com Contents Introduction essai eke anaes 1 Peatures seinna nucle etl acetic alien A e 2 Types or Tunnels iz 5s east e tents letter n a 4 TJB 16 Junction BOX oe esescsseeeeseseeneseesesseeneeesenenees 5 Power Requirements and Construction 6 Connectors and PLUGS seseeeseeeeseseenesceeesseeneeeeneaees 7 Controls and Indicators 8 Pera N ess a ean ea rena ani etd EI EAE 10 In Case of Difficulty sssssessseseeeeeseeeeresrerrrerierirsrerrerse 11 Specification Siina iaie eh ae E R KO 12 Items manufactured by companies other than Smith Root carry the original manufacturer s warranty Please contact product manufacturer for return instructions All Smith Root Inc manufactured products are covered by a one year warranty Credit amp Refund Policy Customers returning equipment in new condition will be given credit to the applicable VISA Master Card account within five days from the date of the return A return authorization must accompany returns Valid equipment returns include but are not limited to ordering incorrect equipment funding deficits and defective equipment returned for reimbursement All returns are s
4. ble on a custom order basis Principle of Operation Operation of the SR 1601 Counter is based on the Balanced Resistance Bridge Principle using water in the count head as two elements of a four element Balanced Bridge Passage of a fish through one of the tubes of the count head causes corresponding changes in that tube s conductance These conductance changes are used by the SR 1601 to sense the presence of fish in the tubes of the counting head 2 www smith root com 1601 Fish Counter Advanced Features The SR 1601 employs numerous advanced features providing such functions as to simultaneously monitor 16 different tunnels giving real time distribution of counts The counts are displayed on liquid crystal displays LCDs which provide easy readability even in direct sunlight The count is retained by internal batteries for up to 5 years if power to the fish counter is lost Also included is a wide range sensitivity control which provides the ability to set the size of the smallest fish that will be counted Water Conditions The counter is designed to work in fresh water with a conductivity of 10 to 500 microsiemen The 16 tube counting head must be completely submerged in fresh water and an appropriate water head developed to overcome the swimming ability of the fish to be counted The fish are then crowded into the vicinity of the tube entrances where they are pulled through and counted With proper tube size and
5. d to allow machine compliance with Product performance and reliability specifications 9 ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR USE SHALL BE LIMITED TO THE DURATION OF THE FOREGOING LIMITED WRITTEN WARRANTY OTHERWISE THE FOREGOING LIMITED WARRANTY IS THE CONSUMER S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED SMITH ROOT INC SHALL NOT BE LIABLE FOR SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO LOSS OF ANTICIPATED BENEFITS OR PROFITS LOSS OF SAVINGS OR REVENUE PUNITIVE DAMAGES LOSS OF USE OF THE PRODUCT OR ANY ASSOCIATED EQUIPMENT COST OF CAPITAL COST OF ANY SUBSTITUTE EQUIPMENT OR FACILITIES DOWNTIME THE CLAIMS OF ANY THIRD PARTIES INCLUDING CUSTOMERS AND INJURY TO PROPERTY RESULTING FROM THE PURCHASE OR USE OF THE PRODUCT OR ARISING FROM BREACH OF THE WARRANTY BREACH OF CONTRACT NEGLIGENCE STRICT TORT OR ANY OTHER LEGAL OR EQUITABLE THEORY EVEN IF SMITH ROOT INC KNEW OF THE LIKELIHOOD OF SUCH DAMAGES SMITH ROOT INC SHALL NOT BE LIABLE FOR DELAY IN RENDERING SERVICE UNDER THE LIMITED WARRANTY OR LOSS OF USE DURING THE PERIOD THAT THE PRODUCT IS BEING REPAIRED 10 Some states do not allow limitation of how long an implied warranty lasts so the above warranty limitation may not apply to you the Consumer Some states do not allow the exclusion or limitation of incidental and consequential damages so certain of the above l
6. ed that the sensitivity control is set correctly reset the displays and begin counting fish Note The water flow through the count head can have a dramatic affect on the accuracy of the fish counter The hydraulics must be such that the fish cannot resist the pull of the water as it passes through the tubes Tube size is also important and must be such that only one fish at a time can pass through a particular tube Fish may go through different tubes at the same time without any error occurring Air bubbles and debris passing through the tubes must also be kept toa minimum With proper tube size and water flow count accuracy is better than 98 Cable runs greater than 50 feet should be made in conduit 4 0 www smith root com 1601 Fish Counter In Case of Difficulty Counter will not count 4 5 Power Switch turned OFF Count Switch turned OFF Sensitivity Control set too low Battery dead or connected backwards Count head not connected to fish counter Counter not accurate 4 5 Battery low check Sensitivity Control set too low Air bubbles accumulating in count head tubes Debris passing through tubes Attempting to count fish that are too small for the tube size More than one fish 6 at a time passing through the tubes Insufficient draw through tubes Fish able to resist going through tubes or fish re entering tubes after passing through Increase the depth of the wat
7. er on the upstream side of the count head Be careful not to increase too much or fish may be damaged www smith root com 41 1601 Fish Counter Specifications Count Rate 10 counts second tube max Count Capacity Channel cee 999 999 6 digit Count Sensitivity mMax eeee 5 tube unbalance Power Requirements 120VAC 60Hz or 12VDC Battery Life 4 days depending on water conductivity SZC yeh esetisads x ied wdeaveddoes nests ted eh edctoutends 21 5 x 9 5 x 9 2 Weight oh catariededneesiteratee 35 pounds including battery Specifications subject to change without notice 4 2 www smith root com WARRANTY Smith Root Inc original products have a 1 Year Limited Warranty Smith Root Inc warrants that it s Products are free from defects in material and workmanship that result in Product failure during normal usage according to the following terms and conditions 1 The limited warranty for the Product extends for the length of ownership beginning on the date of the purchase of the Product by the original purchaser Consumer of the Product and is not assignable or transferable to any subsequent purchaser or user 2 The limited warranty extends only to Consumers who purchase the Product from Smith Root Inc or an authorized distributor 3 During the 1 year limited warranty period Smith Root Inc will repair or replace at Smith Root Inc s sole option any defective par
8. he Product prepaid and insured Expenses related to removing the Product from an installation are not covered under this limited warranty d The Consumer will be billed for any parts or labor charges not covered by this limited warranty The Consumer will be responsible for any expenses related to reinstallation of the Product e Smith Root Inc will repair the Product under the limited warranty within 30 days after receipt of the Product If Smith Root Inc cannot perform repairs covered under this limited warranty within 30 days or after a reasonable number of attempts to repair the same defect Smith Root Inc at its sole option will provide a replacement Product or refund the purchase price of the Product less a reasonable amount for usage f If the Product is returned during the limited warranty period but the problem with the Product is not covered under the terms and conditions of this limited warranty the Consumer will be notified and given an estimate of the charges the Consumer must pay to have the Product repaired with all shipping charges billed to the Consumer If the estimate is refused the Product will be returned freight collect If the Product is returned after the expiration of the limited warranty period Smith Root Inc s normal service policies shall apply and the Consumer will be responsible for all shipping charges 8 The Product consists of newly assembled equipment that may contain used components that have been reprocesse
9. henever the fish counter is connected to 120VAC 60 Hz outlet Count Test The switch is used to test the general functioning of the SR 1601 With the Power and Count switches ON and count head connected pressing this switch causes a single count to be registered on each display Counter must be connected to a properly submerged tunnel to properly test count Count Reset Resets all the displays to zero Count Displays The SR 1601 has 16 individual displays one for each counter tube They are 6 digit LCD displays which means they can be read even in direct sunlight The 16 displays give a real time distribution of counts for each tube in the count head www smith root com 9 1601 Fish Counter Operation 1 Submerge the count head in water making sure that all of the tubes are completely filled with water Locking screws must be locked to nuts on counter 2 Turn the Power Switch ON It is normal for one or two counts to appear on the displays when the power switch is turned on and off 3 Press the Battery Test switch and check the condition of the battery 4 Turn the Count Switch ON 5 Allow a few fish to pass through the count head and adjust the sensitivity control clockwise until the counter reliably counts fish as they pass through the tubes Turn the sensitivity control up one more mark 6 Count accuracy may be checked by hand counting the fish that are passed through the count head When you are satisfi
10. imitations or exclusions may not apply to you the Consumer This limited warranty gives the Consumer specific legal rights and the Consumer may also have other rights which vary from state to state 11 Smith Root Inc neither assumes nor authorizes any authorized service center or any other person or entity to assume for it any other obligation or liability beyond that which is expressly provided for in this limited warranty including the provider or seller of any extended warranty or service agreement 12 This is the entire warranty between the Smith Root Inc and the Consumer and supercedes all prior and contemporaneous agreements or understandings oral or written relating to the Product and no representation promise or condition not contained herein shall modify these terms 13 This limited warranty allocates the risk of failure of the Product between the Consumer and Smith Root Inc The allocation is recognized by the Consumer and is reflected in the purchase price 14 Questions concerning this limited warranty may be directed to Smith Root Inc 14014 NE Salmon Creek Ave Vancouver WA 98686 360 573 0202 Smith Root Inc is a registered trademark of Smith Root Inc SNITH ROOT INC AA Tedilogy For Fisheries Conservation www smith root com
11. s with the internal 12V batteries A battery test button is provided to determine the proper time for battery change An internal battery backup is provided to preserve count data during power failure and while changing the main battery Mechanical Construction The counter and sealed battery are housed in a weather proof aluminum case for protection from the elements The case measures 21 5 inches wide and 9 5 inches deep x 9 2 inches high A twenty five pin data plug provides a quick change connection for the submersible counting heads Each head is supplied with 15 feet of cable and mating connector 6 www smith root com 1601 Fish Counter Connectors and Plugs The tunnel connector is a 25 pin data connector with screw locks The lower section of the 1601 houses the AC power supply connector and optional batteries 12 Volt DC power to the SR 1601 is provided through a single multi pin quick twist positive locking polarized connector This insures easy and positive connections AC power is plugged in via a standard AC cord Up to two optional 12VDC batteries can be housed in the lower battery compartment and connected via spade connectors which goes to the 4 pin plug on the bottom of the counter unit A similar 4 pin plug is also on the front panel to allow the connection of an additional 12VDC power source TUNNEL ws Va SR 1601 POWER SUPPLY XG Connector 12 COnnector
12. ts or any parts that will not properly operate for their intended use with new or refurbished replacement items if such repair or replacement is needed because of product malfunction or failure during normal usage No charge will be made to the Consumer for any such parts Smith Root Inc will also pay for the labor charges incurred by Smith Root Inc in repairing or replacing the defective parts The limited warranty does not cover defects in appearance cosmetic labels or structural items including framing and any non operative parts Smith Root Inc s limit of liability under the limited warranty shall be the actual cash value of the Product at the time the Consumer returns the Product for repair determined by the price paid by the Consumer for the Product less a reasonable amount for usage Smith Root Inc shall not be liable for any other losses or damages These remedies are the Consumer s exclusive remedies for breach of warranty 4 Upon request from Smith Root Inc the Consumer must prove the date of the original purchase of the Product by a dated bill of sale or dated itemized receipt 5 The Consumer shall bear the cost of shipping the Product to Smith Root Inc Smith Root Inc shall bear the cost of shipping the Product back to the Consumer after the completion of service under this limited warranty 6 The Consumer shall have no coverage or benefits under this limited warranty if any of the following conditions are applicable a The
13. ubject to a restocking fee and applicable shipping charges The restocking fee is figured at 10 of the purchase price but not less than 20 00 Customers receiving equipment in damaged condition will be referred to the shipping company for insur ance reimbursement Rev 07289 01 Smith Root Inc Vancouver WA USA I www smith root com 1601 Fish Counter Model SR 1601 Electronic Fish Counter The SR 1601 Fish Counter is a 16 channel fish counter integrating 16 individual counters into one unit This unit is designed for hatchery fry migrating smolt fish eggs emergent shrimp and other macro organisms The SR 1601 simultaneously monitors all 16 tunnels for downstream movements giving individual counts for each tunnel In order to be counted macro organisms pass through one of multiple counting tunnels and are tallied on separate 16 digit displays The system easily tallies 10 counts per second per channel giving 576 000 counts per hour www smith root com 41 1601 Fish Counter General Description The Model SR 1601 Fish Counter features a balanced resistance bridge circuit using the tunnel elements to count fish in fresh water Electronic counters simultaneously monitor up to 16 tubes for downstream fish movements giving a real time readout for each tube showing count distribution The counting heads are interchangeable and are available with tube diameters ranging from 1 2 to 3 inches Larger tunnels are availa
14. water flow count accuracy is better than 98 www smith root com 3 1601 Fish Counter Counting Head The SR 16 CH Counting Head is a single unit containing 16 separate counting tubes Each tube in the Counting Head has a smooth tapered entrance to prevent abrasive damage to the fish The tubes may have diameters ranging from 1 2 to 3 inches Tubes are usually arranged in two rows of 8 tubes each For the best accuracy tube diameter should be no more than half of the length of the fish to be counted Single Tunnel For most fish counting opera tions individual tunnels are connected to the 1601 via the TJB 16 Junction Box which in turn is connected to the 25 pin connecter on the panel of the counter Up to 16 individual tunnels can be connected in this manner 4 www smith root com 1601 Fish Counter TJB 16 Junction Box Allows the connection of up to sixteen individual tunnels to the 1601 Fish Counter Signal cables pass through a strain relief and connected to screw terminals on an isolated strip which is connected to a 25 pin female plug that corresponds to the 1601 s Tunnel plug Unit is housed in a waterproof enclosure TB 1G sicsscsscessssssesssseres 3360 www smith root com 5 1601 Fish Counter Power Requirements The Model SR 1601 can be powered from 115VAC 60Hz from an optional 12 Volt internal battery or from an optional 12 Volt external battery Battery life is four day