Home
manual
Contents
1. Petri dish for several days A small amount of moisture will encourage the mold growth Again be sure to wash hands thoroughly after Many specimens may look transparent under the microscope It s common to stain them to make the cells show up better Iodine is a common stain Or try soaking your tissue specimens in a solution of ordinary food color included add water to thin for a couple of minutes to stain them Use the tweezers to pick up the stained specimen Allow the stained specimen to dry before using glue to mount it Remember the stain will color anything else it touches not just your specimen so be careful with furniture and clothing 7 Preparation Please read this section completely before using your microscope Study page 2 to learn the various parts of the instrument Remove the eyepiece from the tube and invert the microscope to reveal the battery compartment Open the compartment and insert 3 AA Batteries not included as indicated Base of battery negative end goes against the spring Replace the battery compartment cover and the eyepiece Always set up your microscope on a smooth surface such as a desk or table Before using the scope practice slowly turning the focusing knob and watching the stage move without looking through the eyepiece so as to familiarize yourself with the direction you should turn the knob when moving the stage closer to the objectives The My First Lab BUO S COPE
2. Suggestions for Making Your Own Prepared Microscope Slides Always begin with clean slides and cover glass Handle slides carefully by the edges to avoid fingerprints Use forceps tweezers to carefully handle cover glass Extreme caution and adult supervision recommended when using the scalpel blade for cutting specimens Keep scalpel covered and store in a safe place when not in use Temporary or Wet Mounts Tissue type specimens such as plant sections 1 Use the scalpel to carefully cut the specimen as thin as possible 2 Place the specimen on the slide 3 Use the plastic dropper to place one drop of water on the specimen 4 Carefully place a cover glass over the specimen allowing the water to spread under the glass 5 The cover slip should be flattened against the specimen and slide as much as possible avoiding air bubbles Use caution the thin cover glass will break if too much pressure is applied 6 Blot any excess water carefully with paper tissues 7 Carefully place slide on the microscope cover glass side up and observe 8 Use the slide labels to identify your specimens You may want to try reversing steps 2 amp 3 place a drop of water on the slide first then put the specimen on the water before placing the cover glass Experiment with each method to find the best results for each specimen Keep in mind these are only temporary mounts Tip Slides may be carefully washed and re used for future
3. e this is normal Always move the focusing knobs very slowly 5 to avoid breaking the slide with the objective When changing slides move the stage to its lowest position lift the clips to remove and replace slides and begin observing with the 4X objective again Stereo Microscope Use for solid objects Turn on the overhead illuminator to shine light onto the stage As with the compound microscope always begin your observation with the 4X objective and increase magnification accordingly Note Only the 4X and 10X objectives may be used when viewing solid specimens The 40X lens is not suitable for use with the upper lighting due to the focusing distance required The lens must be too close to the specimen and does not allow any light to reach the specimen For contrast you may find it necessary to place certain specimens on an index card or small piece of paper before centering them on the stage Since you are using the upper light it is not necessary for the opening in the stage to be exposed for the lower light to shine through Also you do not want your specimen to fall through the hole This application can allow you to magnify countless everyday items for examples small rocks leaves insects flower petals coins stamps jewelry and more Focusing Tips You will notice that with a three dimensional specimen for example a small insect you will have different levels to focus on therefore the entire image may not s
4. eem clear at the same time Compare to a flat field such as a postage stamp where the specimen is all at the same level which allows the microscope to focus on the entire field With a little practice you can soon become an expert at observing all types of specimens with My First Lab DBUO SCOPE 6 Accessories This microscope is equipped with the following accessories 5 Blank Slides 4 Prepared Slides 1 Concavity Slide Slide Labels Cover glass Plastic Dropper 2 Bottles of non toxic stain Scalpel Forceps Lens Paper Test Tube Petri Dish Straight Teasing Needle Vinyl dust cover Note Contains glass food coloring and sharp instruments Adult supervision required for experiments and slide preparation Simple Semi Permanent Mounts Follow the same basic procedure as above but try using CLEAR GLUE instead of water to hold the specimen and cover glass to the slide Allow the glue to dry before observing the specimen Use the slide labels to identify your specimen Hint You may enjoy keeping notes of your various observations or even sketching the magnified images you see in the scope Maintenance To prolong the life of your batteries turn off the power immediately when not in use be sure both lights are off switch in the center position Dust the unit with a soft dry cloth or soft brush Fingerprints and debris may be removed with a damp cloth If glass lenses require cleaning try a cott
5. ge prepaid to the address below It will be repaired or replaced at no charge and returned If misuse alterations accident or abnormal conditions of operation caused failure an estimate for repairs will be provided for your approval prior to work being performed If you have questions concerning this product or warranty contact the dealer from whom it was purchased My First Lab DUO SCOPE Two Microscopes in One USER S MANUAL Model MFL 06 This microscope is intended for use by ages 9 amp older Parents are reminded this is a scientific tool and contains glass microscope slides and sharp instruments Proper handling and parental supervision is required Always follow the appropriate safety procedures
6. h the different parts of your microscope Eyepiece tube i 10X Eyepiece Disc Diaphragm Some Ideas For Observation Children get adult s permission before trying any experiments 1 Crystals Place a few grains of dry salt or sugar on a slide to observe Mix salt with a spoonful of warm water in the test tube and then use the plastic dropper to place a couple drops on a slide Let it dry and observe the re crystallized salt sugar Shake some grains of pollen from a flower onto a blank slide Hairs including pet hair or pieces of feathers can be observed Try comparing hairs from various animals You can use a small piece of tape at each end of the hair to hold it on the slide Observe fibers in different kinds of paper printing from a newspaper or typewriter Look at the color in comics Threads or fibers from different types of fabric Compare natural fibers such as cotton and wool to synthetics like polyester Stagnant water from a pond will contain live organisms Place a drop into the well of a concavity slide for observation Very small insects may be seen completely under low power or try looking at parts such as legs or wings of larger bugs The teasing needle is useful for positioning or probing the specimen Always handle insects with tweezers and wash hands thoroughly after working with your specimens Observe the mold on old bread or other food or make your own mold by leaving a small piece of bread in the
7. has the capability to illuminate the specimen from the top or bottom Notice the power switch located at the back of the scope operates both the top light and the bottom light but not at the same time depending on which way the switch is flipped The eyepiece tube and head may be rotated to face the other side of the microscope if desired If necessary you may loosen the screw at the base of the head SLIGHTLY to allow the head to move with ease For best results only move the head when necessary Operation Compound Microscope Use for slides Begin with the stage platform at its lowest position To observe specimens check the objective lens and if necessary rotate the nosepiece so that the 4X objective lens is in position for viewing The lens will click when in place Always start viewing any specimen with the 4X objective and increase accordingly Begin by selecting a prepared slide and placing it carefully on the stage labeled side up Push gently on the back of the clips to lift the arm enough to slip the slide under and hold it in place The main part 4 of the specimen should be centered over the opening in the stage Turn on the lower illuminator to shine the light up through the stage and through the tissue specimen on the slide Look through the eyepiece and SLOWLY turn the focusing knob until the image of the specimen becomes clear Be careful not to let the slide touch the lens Focusing Tips When focusing you
8. on swab very slightly moistened with alcohol Dry with a clean swab or lens paper Store your microscope in a cool dry place Always cover with the vinyl dust cover provided or return to the box when not in use If used in the field take care to keep the unit upright as the eyepiece can fall out if tipped Eyepieces and lenses should remain in place to avoid dust in the tubes Keep microscope slides in their proper storage unit when not in use Always use care with real glass and sharp instruments and keep out of reach of young children When lights seem dim replace the batteries with fresh AA batteries The LED bulbs have a long life span and should not require replacing If either bulb does not work even after installing fresh batteries please call for service Proper care and use of this product can result in years of scientific study and adventure Enjoy LIMITED ONE YEAR WARRANTY The manufacturer warrants this instrument to be free from defects in material and workmanship under normal use for one year from the date of purchase It does not cover damage resulting form abuse or misuse repairs or alterations performed by other than authorized repair technicians or damage occurring in transit For warranty service microscope should be well packed to avoid damage in transit preferably in original box and packing Include your complete return address and telephone number as well as a description of the difficulty and ship posta
9. r microscope turn the knob only until the stage stops moving DO NOT FORCE IT The disc diaphragm located directly below the stage has six different apertures openings which allow various amounts of light to pass through Rotating this disc allows you to modify the amount of light that is transmitted Try experimenting with various settings to get the best effective view Usually most effective at the 400X magnification After focusing you can move the slide left or right on the stage to observe different sections of the same specimen As you adjust the slide or the aperture disc be careful not to put weight against the stage as this could push it out of focus If this occurs simply readjust the focusing knobs slightly until you again have a clear view After observing with the 4X objective which shows you the image magnified 40X rotate the nosepiece to the 10X objective lens leave the slide in place on the stage SLOWLY turning the focusing knob will enable you to get a clear view of your specimen at 100X magnification Always use caution since the focusing knob actually moves the stage closer to the objective lens Finally you can turn the nosepiece to the 40X lens giving you a 400X magnification of your slide When increasing magnification always remember that the higher the magnification the closer the objective must be to the specimen being observed Focusing Tips The 40X lens will appear to be almost touching the slid
10. specimens Cover glass is extremely fragile and not recommended for re using Carefully discard after use 8 With the new My First Lab BUO S COPE you finally have the ability to observe both microscope slides and solid objects such as plants coins and insects The key is in the dual cool LED illumination that provides both sub stage and overhead lighting Battery power eliminates the need for electricity or power cords and allows for portable use in the field The new My First Lab DUO SCOPE combines two separate applications into one fantastic package that promises hours of fun and learning Magnifications Total magnification is calculated by multiplying the eyepiece magnification always 10X by the objective lens Objectives Compound use Stereo use lower lighting upper lighting 4X 40X 40X 10X 100X 100X 40X 400X N A Note the 40X lens is not suitable for use with the upper lighting due to the focusing distance required The lens must be too close to the specimen and does not allow enough light to reach the specimen Specifications 10X Eyepiece Rotatable Head 4X 10X 40X Objectives Dual LED illumination Dual focusing knobs Disc Diaphragm Real optical glass lenses Dimensions 4 2 x 6 2 x 11 high Net Weight 1 95 Ibs Instrument is powered by 3 AA Batteries not included Components of My First Lab BUO SCOPE Study the picture below to become familiar wit
Download Pdf Manuals
Related Search
manual manual manualslib manual car manuale digitale manual transmission manually meaning manual timesheet manual wheelchair manual arts high school manual of state funds manually update your device drivers windows manual definition manual for courts martial manual lawn mower manual labor manual muscle testing manual muscle testing grades manual transmission cars for sale manually register devices with autopilot manual blood pressure cuff manualidades manual transfer switch manual handling manual digital manual on uniform traffic control devices
Related Contents
Kensington Universal Multi-Display Adapter User`s Manual - TOMCOPY Automation 報告様式2_確認・記入要領 Electrolux Enviro Steamer 313A Cables Direct NLTFTARM-183BLK flat panel desk mount Android Phone Integration User`s Manual I IC Bedienungsanleitung Zenit.pmd Online Data Validator User`s Manual T3 UPS service manual 6kVA - 10kVA Copyright © All rights reserved.
Failed to retrieve file