1. lt FupiroR AUDITOR DC I II DATA COLLECTOR Operations Manual AIMCO e a a ee PO Box 16460 Portland OR 97292 0460 503 254 6600 Fax 503 255 2615 www aimco global com Auditor DC I Il Manual Table of Contents Page No CE Marking 3 How to use this Manual 3 Packing List 4 Care amp Storage 5 Battery Charging 5 Edit Transducer File 6 Barcode Read Input 8 Measure Mode Up to 200 readings stored 9 Measure Mode circle store option 10 Direct measure Mode 11 To Display Recorded data 13 To View Cp and Cpk 13 French Cp and Cpk 14 To Erase Stored Data and Set ups 15 To Erase readings stored in measure mode 15 Printing 16 To print readings taken in measure mode 16 To set Date and time 17 To Set power off and Backlight Time Delays 17 To Configure Printer Port 17 To Display Software Version Number 17 To set Password Protection 18 To clear Password Protection 18 To Perform Software Reset 20 To Communicate With a PC 21 Example printouts 22 Printout of Readings taken in measure mode 22 Glossary of Terms 23 Error Messages 25 External Connectors 27 CE Marking PO Box 16460 Portland OR 97292 0460 503 254 6600 Fax 503 255 2615 www aimco global com Auditor DC I Il Manual Declares that this product has been assessed and complies with the reguirements of the relevant CE Directives How to use this Manual This manual is split into sections describing the steps to be
2. Each characteristic has a name of up to 14 characters 8 if downloaded from a PC Auditor DC can store up to 48 different characteristics at any one time This is a capability index which shows the process capability potential but takes no account of how centred the process is This is used for capability studies and Cp may range in value from O to infinity A large value indicates greater potential capability and a value of 1 33 or greater is desirable Max Min Cp 6 Max and Min are limit values This is an index which indicates whether the process will produce units within the tolerance limits If the process is centred on the nominal value then CpK will have a value equal to Cp For values of CpK between 0 and 1 then some of the 6 sigma spread will fall outside tolerance limits but for values greater then 1 these will all be within tolerance A negative value of CpK indicates that the process mean is outside tolerance limits A value of 1 33 or greater is desirable Max _ Min CpK lesser of 3 or 3 Max and Min are limit values This is an alternative capability index requiring a minimum of 30 readings to be taken In this implementation 5 sub groups of 6 samples are used for each calculation The CAM calculation uses the following formula Max_ Min x Cam Factor 6 x Average Sample Value CAM Factor is taken from a table in the case of 5x 6 samples 1 910 Torque transducer with no coding links but in
3. If you have selected KPD Select location of decimal point using then Select Parity Odd Even or Disabled using then To set up another transducer Select another memory B to I using the keys and To return to main menu If you have selected KEY Select location of decimal point using then To set up another transducer Select another memory B to I using the keys and To return to main menu press f Barcode read input for characteristic names and comments It is now possible to scan a barcode name in Auditor DC at certain prompt lines The input of a barcode is allowed at the characteristic name prompt in store characteristic direct characteristic and edit characteristic modes In addition it is also possible to scan a barcode in the comment field in store characteristic only Edit characteristic and normal store behave in a slightly different manner to direct characteristic The Auditor DC will accept most bar code reading formats but not all General Operational Method for Scanning bar Code data Connect the Bar Code Reader to the Printer PC connector at the rear of the Auditor DC Bar code readings can generally be taken at the prompt to input data Characteristic name or a comment when the flashing cursor is on the screen This can be on a blank line or following a line of data an existing characteristic or a comment When the cursor is flashing swipe the code with a bar code reader and observe the screen If the flash
4. 503 254 6600 Fax 503 255 2615 www aimco global com 21 Auditor DC I Il Manual Printout of Readings taken in Measure Mode AUDITOR DC 07 01 95 12 39 12 MEASURE Peak Capability Results Torgue No of Samples 200 Based on last 15 samples Transducer A UTA 75 00 Nm x 6 96 Nm Serial Number 99999 Range 8 30 Nm Measurement Dir Right Sigma 2 210 Max Torque Value 20 00 Nm Cp 0 754 Min Torque Value 10 00 Nm Cpk 0 458 Thrshld Torg Val 2 00 Nm Max found 12 65 Nm Freg response 1676 Hz Min found 4 35 Nm Cycle end time 0 1 Sec Readings above max 0 Readings below min T3 Percentage not OK 86 66 Date Time Torque 1 07 01 95 12 38 32 7 21 LO 2 07 01 95 12 38 35 4 87 LO 2 07 01 95 12 38 38 6 65 LO 4 07 01 95 12 38 40 6 56 LO 5 07 01 95 12 38 42 7 45 LO 6 07 01 95 12 38 45 5 76 LO 7 07 01 95 12 38 47 7 07 LO 8 07 01 95 12 38 49 12 65 9 07 01 95 12 38 52 9 37 LO 10 07 01 95 12 38 54 5 29 LO 11 07 01 95 12 38 56 6 09 LO 12 07 01 95 12 38 59 4 35 LO 13 07 01 95 12 39 01 5 90 LO 14 07 01 95 12 39 04 5 25 LO 15 07 01 95 12 39 06 10 03 PO Box 16460 Portland OR 97292 0460 503 254 6600 Fax 503 255 2615 www aimco global com 22 Glossary of Terms Characteristic Cp CpK CAM High Output Transducer H O Horizontal sampling Industry Standard Transducer IS Master Round Max Torgue Auditor DC I Il Manual Specification of one particular torgue value to be collected
5. CODE ERR STACK ERR TX SPEC TX TYPE TX UNITS SERIAL UNITS DIRECT NAME RANGE RS232 TIMEOUT CRC ILL MSG Auditor DC I Il Manual Invalid RS232 data on the serial input Incorrect time or ate format Only one round programmed so not possible generate master round No rounds programmed so not possible to generate master round This round has already been entered into the master round It is not possible to enter a round twice The round is complete no skipping is allowed All other characteristics have already been skipped Message on power up if memory error found See 6 4 Invalid menu entered due to fault The EPROM has an error The processor has attempted to execute an illegal instruction The processor stack has overflowed Illegal transducer specification number received from PC Illegal transducer type received from PC Illegal transducer units data received from PC Illegal serial transducer data received from PC Illegal units of measure data received from PC Illegal direction data received from PC Name sent from PC is too long Numeric Parameter sent from PC is out of range Error receiving RS232 data from PC Timed out receiving message from PC Message received from PC has incorrect CRC value Illegal message received from PC PO Box 16460 Portland OR 97292 0460 503 254 6600 Fax 503 255 2615 www aimco global com 26 Auditor DC I Il Manual NOTE If Au
6. prompt Enter new Password Type in the password 4 characters and press Screen will prompt confirm password Press to accept or to reject Select desired option using Gb Options for protection are Power up Configure Direct Measure Direct Char Software Reset Date and Time oonon gt Press to protect your selected option or fe to exit NOTE when an option is password protected appears in the top right of the display window Pressing will remove the protection Press fe to exit Display now reads End of set up To return to main menu press fe or press to edit password protection The remaining options can be password protected in the same manner To clear Password Protection From main menu Press then press 6 or press 6 Misc Press then press 5 or press 5 Password Screen will prompt Password Enter the existing password 4 characters and press Screen will prompt Confirm Password and display the existing password Press to confirm or press to clear the password protection Screen will prompt Enter new Password Press to clear the password keying in 4 characters before pressing will result in a new password being created Screen will say Confirm password Press to confirm and password is cleared PO Box 16460 Portland OR 97292 0460 503 254 6600 Fax 503 255 2615 www aimco global com 18 Auditor DC I Il Manual Notes on Password Protection Be awar
7. return to main menu press f f There are a number of other parameters which are set from the Software Reset Menu some of which are detailed elsewhere in this manual Pressing after making a selection will take the user on to the next screen Pressing fe will give the user the option to exit to the Misc menu by pressing fe or continuing to edit by pressing 2 Screens can be skipped using the and keys These are the settings in the order they appear when the Software Reset Menu is accessed Cm max samples type in the required figure Cm min samples type in the required figure Language select using cS Autoprint mode select using 3 g Capability label select using lt Cpk Calculation select using lt Circle store On Off select using lt Shift key mode select using a PO Box 16460 Portland OR 97292 0460 503 254 6600 Fax 503 255 2615 www aimco global com 20 Auditor DC I Il Manual To Communicate With a PC optional software required Connect Auditor DC to PC via cable provided On PC start PCComms Software On Auditor DC Press Press fey Press then press or press You can now set up and view all information data via the PC NOTE This optional PC software is used primarily to write and store characteristics and rounds on the PC The format of the data stored on the PC is of little use to the computer operator without further processing PO Box 16460 Portland OR 97292 0460
8. taken to configure the Auditor DC for use in measuring and recording torgue values The following method is adopted throughout this manual Keys to be pressed will be shown as the key legend in large type Example Any special instructions or point to note will be shown as eee INSTRUCTION TO BE FOLLOWED Refer to the table of contents to find action to be performed Follow instructions for key presses required to carry out required action Note It is possible to change the default primary character on dual function keys l e when text is entered into various fields it is possible to set the Auditor DC to default to either the numerals or text as the primary character the alternate character is selected by pressing the shift key before typing To set this from Main Menu Press gt then press 6 or press 6 Misc Press gt then press 6 or press 6 Software Reset Press the Q 7 times to access the Shift key menu Select between options 1 Characters or 2 Numbers using Press pen Screen will prompt End of set up Press een fe to return to main menu PO Box 16460 Portland OR 97292 0460 503 254 6600 Fax 503 255 2615 www aimco global com Auditor DC I Il Manual Packing List The following items are included in the carrying case supplied with the Auditor DC unit 1 x Auditor DC 1 x Auditor DC fastcharge model 1 x Camera Neck Strap 1 x Camera Neck Strap 1x 9 way D type to 9 way D type PC cab
9. 03 254 6600 Fax 503 255 2615 www aimco global com 12 Auditor DC I Il Manual To Display Recorded Data From main menu press 9 Display Analyse Screen will show job name and Specs press Screen will now show x bar R and sigma for total readings From any Subgroup display press down arrow Screen will show the Date and Time the readings for that subgroup were taken Press down arrow screen will show subgroup comment Press down arrow again to see the individual readings displayed in groups of four readings per screen To View Cp and Cpk At the job name spec screen press down arrow screen will show the Cp and Cpk and the number of samples used in the calculations press down arrow Screen will now show x bar R and sigma based on all of the data all subgroups calculated together The number of samples that were NOK will also be displayed expressed as a percentage Press down arrow Screen will show the highest and lowest torgue s recorded and the number of readings that were above the maximum torgue value and minimum torgue value To return to the main menu press fe For more information on Cp Cpk and CAM please refer to the glossary on page 23 PO Box 16460 Portland OR 97292 0460 503 254 6600 Fax 503 255 2615 www aimco global com 13 Auditor DC I Il Manual French Cp and Cpk It is possible to view the French Cpk CAM calculations as an alternative to the standard Cp and Cpk Readings mu
10. at the unit is being recharged From fully discharged the unit will require a charging period of 16 20 hours The batteries in the unit comprise a 7 cell NiCad with a capacity of 1 6Ahr With the unit switched off from a 10 charge state the batteries will fully discharge in 25 50 days To prevent the loss of all set up data the unit has additional battery backup for the internal memory Automatic Power Off To conserve battery life in use the unit will switch off automatically after a predefined period Pressing the on key will restore the unit to the last display prior to powering off Optional Fast Charge Auditor DCs with optional Fast Charge are supplied with internal NiMH Nickel Metal Hydride batteries These are environmentally friendly batteries presenting no problems for safe disposal and are capable of sustaining a rapid recharge From fully discharged the unit will require a charging period of only 2 5 hours approx Auditor DC model having this feature are identified by the additional green LED next to the existing LED above the mains adapter socket When the mains adapter is plugged into the socket and switched on at the mains the green LED will come on to indicate the machine is charging and will start to flash when the unit is fully charged If the red LED comes on this means there is a problem and usually indicates a faulty battery The Fast Charge option also gives an increase in the effective life of the charged batterie
11. de Pressing P from the measure mode will result in all stored readings being printed to an attached printer Note Transducer needs to be connected to Auditor DC Measure mode circle store option Circle Store is a function to increase the number of stored readings to extend beyond the normal maximum of 200 readings possible in measure mode With the circle store option selected readings will be accepted beyond the 200 limit but the first readings taken will be lost Effectively the last 200 readings taken will be stored but the user is not limited to taking only 200 readings To select this option From main menu Press then press 6 or press 6 Misc Press then press 6 or press 6 Software Reset Press the 6 times to access the Circle store menu Select option 2 Circle store On using press Press fe Screen will prompt End of set up Press 29 to return to main menu PO Box 16460 Portland OR 97292 0460 503 254 6600 Fax 503 255 2615 www aimco global com 10 Auditor DC I Il Manual Direct Measure Mode Smart Type transducers only Direct measure mode is to allow an operator to connect different transducers which may have different spans and an angle output and can switch between them using an external T switch This is a display only function and readings are not stored or printed out Tostart press press fe press 4 Direct press 1 Direct Measure press 1 Set up select units of measure usin
12. ditor DC can be switched on but fails to respond to the keyboard the electronic circuitry may be reset by linking pins 5 and 6 in the PC connector with a length of wire This will turn the unit off Turn the unit on again by pressing ON If after this reset Auditor DC still fails to operate correctly use 6 for Miscellaneous and 6 Software Reset to clear memory Having carried out a hardware reset as described above the message 800 MEMORY may be displayed on the next power up and a software reset should be carried out External Connections TRANSDUCER CONNECTOR PRINTER PC CONNECTOR 1 OV 1 RTS Ready To Send 2 High Level I P 2 Rx Receive Data 3 5V 3 Tx Transmit Data 9 Ve Excitation 4 DTR Data Terminal Ready 13 Ve Excitation 5 0V 14 Ve Signal 6 Not Reset 15 Ve Signal 7 Analogue O P 8 CTS Clear To Send 9 5V CHARGER SOCKET 4 Centre 12V Outer OV Sir et Ai 3 gt j e GOROHE PF E A P Fet maa cco PO Box 16460 Portland OR 97292 0460 503 254 6600 Fax 503 255 2615 www aimco global com 27
13. e considered a valid torque cycle This may be set in the range of 1 to 50 of rated span or the Min Torque Value whichever is the lower It is possible with Auditor DC to read a transducer calibrated in say Nm and convert internally to display and store in any of the other torque units Collection of data by round where a full sub group is collected for a characteristic before stepping to the next characteristic Identical in procedure to that of Vertical mode except that before stepping to the next characteristic Auditor DC will prompt for the fitting of a transducer even though the correct one is installed and will require the ENTR key to be pressed PO Box 16460 Portland OR 97292 0460 503 254 6600 Fax 503 255 2615 www aimco global com 24 Code 101 104 105 106 107 108 109 110 111 113 114 120 121 122 123 124 200 300 301 Message RANGE EXISTS NO SPACE NONE ON PC CONV OUT OF RANGE NO NAME NO SET UP NO DATA DAT STR ALL STR NO Tx TxID FLT AZ OFSET AZ DISCR Tx FAULT INCOR TX IN ROUND CHARACTS Auditor DC I Il Manual Error Messages Explanation The selection made is not within the allowable range See the limits specified max to min The characteristic name entered already exists Insufficient memory space is available to create a new characteristic No characteristics have been created Characteristic or round wa
14. e of the implications of password protection Always keep a note of the chosen password somewhere safe As there is no function to enable an existing password to be removed without it first being entered it may be advisable for the person who is ultimately responsible for the Auditor DC to initially set a password and issue it only to personnel who need the information This will prevent an unknown password being entered accidentally or deliberately without anyone else s knowledge If an unknown password is encountered please contact AIMCO for advice PO Box 16460 Portland OR 97292 0460 503 254 6600 Fax 503 255 2615 www aimco global com 19 Auditor DC I Il Manual To Perform Software S W Reset CAUTION Use of this function will result in the loss of all stored data Following this procedure will return the Auditor DC to its factory default state This feature should only be used when it is desired to clear all settings from the Auditor DC From main menu Press then press 6 or press 6 Misc Press then press 6 or press 6 s w Reset Press the key 8 times to access the Software Reset screen Screen will display Erase all data and set mode To carry out S W reset press To exit without performing S W reset press res Screen will display ERASING ALL CHARACTERISTICS ROUNDS AND MASTER ROUNDS wait a moment for display to change Select Subgroup mode using and press exe screen will say End of set up To
15. e stamp A sample printout can be found in Appendix A To return to main menu press f PO Box 16460 Portland OR 97292 0460 503 254 6600 Fax 503 255 2615 www aimco global com 16 Auditor DC I Il Manual To set Date and time From main menu Press then press 6 or press 6 Misc Press 1 Set Date Time Select date format using Enter date and time and press To return to main menu press 29 To set Power Off and Backlight Time Delays From main menu Press then press 6 or press 6 Misc Press 2 Select Power Off Backlight Time Delays Select Power Off time delay using press Select Backlight Delay using press To return to main menu press fefe To Configure Printer Port From main menu Press then press 6 or press 6 Misc Press then press or press Printer port Select Baud Rate using then press Select number of data bits using then press Select number of Stop Bits using then press Select Parity using then press To return to main menu press fefe To Display Software Version Number From main menu Press then press 6 or press 6 Misc Press then press 4 or press 4 Version To return to main menu press foc PO Box 16460 Portland OR 97292 0460 503 254 6600 Fax 503 255 2615 www aimco global com 17 Auditor DC I Il Manual To set Password Protection From main menu Press then press 6 or press 6 Misc Press then press 5 or press 5 Password Screen will
16. g press select peak track Impulse or Click Dip using press Note Impulse available on Type II only select measurement direction using Right is clockwise Left is anti clockwise press select Cycle end Time using press select frequency response using press type in the Threshold Percent mx 50 0 mn 0 0 and press type in amount of Dip mx 100 0Nm mn 0 0Nm and press select Second Parameter using press Auditor DC II only Screen shows End of set up press fe to exit Press foc to return to main menu PO Box 16460 Portland OR 97292 0460 503 254 6600 Fax 503 255 2615 www aimco global com 11 Auditor DC I Il Manual The READ option allows you to read the torgue from a connected transducer From the main menu press 4 Direct press 1 Direct Measure press 2 Read If no transducer is connected display will prompt Insert Tx transducer connect transducer and press Screen will show the span of the connected transducer and the torque measured in units selected at set up The display will show the last reading taken until the next torque input exceeds the threshold level set Note if password protection has been set on Direct measure then exit is by password only A correct password returns you to the set up read sub menu Entering three incorrect passwords will force the user back into read mode See password protection later in this book PO Box 16460 Portland OR 97292 0460 5
17. ing cursor disappears the code has been captured wait a few seconds for the data to appear in the display If the flashing cursor remains re scan the code until it is accepted When the data is displayed press to continue From this point follow the instructions as for normal data input When entering data via the bar Code reader into a comment field make sure you have reserved enough characters in the comment field to accept the code If the number of characters scanned in exceeds the number reserved the Auditor DC will beep and refuse to accept the data Refer to the instructions on Configuration for more details PO Box 16460 Portland OR 97292 0460 503 254 6600 Fax 503 255 2615 www aimco global com Auditor DC I Il Manual Measure Mode Up to 200 readings stored To start press Press fe Press 2 measure plug in transducer then press m select proper transducer using then press If using I S or H O type transducers continue with instruct If using SER KPD or KEY you are now ready to take measurements select units of measure using press select peak track Impulse or Click Dip using press Note Impulse available on Auditor DC II only select measurement direction using Right is clockwise Left is anti clockwise press select Cycle end Time using press select frequency response using press type in Max torque value press type in Min torque value press type in threshold torque value pre
18. is 2 mV V they are fitted with a 350 Ohm bridge 3 Serial These are digital type transducers and produce an RS232 signal 4 Keypad KPD This is an optional keypad which connects to the Auditor DC O Keyboard KEY Keyboard on Auditor DC Use of any of the above 5 transducer types requires that settings are made in the transducer file before any measurements can take place The procedure for entering settings is given below At main menu press 1 Configure press 2 Edit Tx Screen will show Transducer B Current set up Complete set up The B indicates that this is the B file in memory It is the first of 8 memories labelled B to reserved for the saving of transducer set ups Your most used transducer setting should be stored in this memory The remaining memories C to I may be accessed by pressing Jb Press Select transducer type H O I S SER KPD or KEY using J E press err Depending on type of transducer selected above continue set up in the appropriate section overleaf PO Box 16460 Portland OR 97292 0460 503 254 6600 Fax 503 255 2615 www aimco global com Auditor DC I Il Manual If you have chosen I S Select units of measure inlb ftlb etc using type in transducer span type in mV V type in Bridge resistance press type in Pulses Per Rev press Auditor DC II only type in serial Number press To set up another transducer press Select another memory B to I u
19. le 1 x 9 way D type to 9 way D type PC cable 1 x 9 way D type to 25 way D type Printer cable 1 x 9 way D type to 25 way D type Printer cable 1 x Charging Unit Max current 500 mA 1 x Fastcharge Charging Unit Max current 1 A 1 x User Manual 1 x User Manual BATTERY CHARGING LED CHARGER j Y SOCKET LED fast charge machines only KEYPAD STATUS LED PRINTER PC TRANSDUCER CONNECTOR CONNECTOR Rear View PO Box 16460 Portland OR 97292 0460 503 254 6600 Fax 503 255 2615 www aimco global com Auditor DC I Il Manual Care amp Storage When not in use the unit should be returned to the supplied carry case This unit is designed for indoor use only Operating temperature range 5 40 degrees C Storage temperature range 0 50 degrees C The membrane keypad may be wiped clean with a soft damp cloth The unit is not waterproofed and spillages should be avoided THIS UNIT CONTAINS NO USER SERVICEABLE PARTS ONLY QUALIFIED SERVICE PERSONNEL SHOULD REPLACE OR FIT PARTS Battery Charging The batteries in the Auditor DC unit are shipped fully charged In continuous use with a transducer connected the batteries have a life of at least 8 hours To charge the batteries following a period of use Connect the supplied charger to the charging socket on the right hand side of the unit Plug in the charger to a suitable supply and switch on The LED indicator above the charging socket will light Red to indicate th
20. s NOTE The mains adapter for the Fast Charge model terminates in a slightly larger diameter plug This prevents the use of a standard mains adapter for charging the fast charge batteries No attempt should be made to recharge the NiMH batteries using the standard mains adapter failure to heed this warning could result in damage to the unit The fast charge adapter can however be used to charge a standard Auditor DC PO Box 16460 Portland OR 97292 0460 503 254 6600 Fax 503 255 2615 www aimco global com Auditor DC I Il Manual Edit Transducer File The following section deals with the editing of transducer files This section can be skipped if using Auditor Smart type Transducers If using any other types of transducer then the following instructions for Edit Transducer File must be followed before any reading or measurements can be taken All Auditor Smart type transducers have in built circuitry which allow the Auditor DC to identify the range of the transducer and calibrate the readings automatically No set up is necessary for these types of transducer There are 5 other types of transducer which the Auditor DC will accept 1 High Output H O these transducers have an internal amplifier and give an output signal level of 1 2 Volts 2 Industry Standard IS These transducers have no internal amplifier The exact span or rated torque will be marked on the transducer nameplate The sensitivity of these transducers
21. s sent from PC These may not be edited or erased on Auditor DC The units selected would generate too great or too small a number A characteristic name must be entered The characteristic exists but configuration is not complete The characteristic exists but no data is stored More than one sub group of data is now stored All of the sub groups for this characteristic have now been collected Erase these after printing to allow further collection UTA Transducer has been selected but none is connected Transducer ID level not recognised Use another transducer or get transducer recalibrated An auto zero calibration on the transducer has detected an excessive offset from zero An auto zero calibration on the transducer has detected an excessive discrepancy between the Tracking and Peak inputs ADC saturation due to transducer fault no transducer fitted or over torque The correct UTA transducer is not connected This characteristic has already been included in the round A minimum of two characteristics must be defined before entering Edit Round PO Box 16460 Portland OR 97292 0460 503 254 6600 Fax 503 255 2615 www aimco global com 25 306 400 600 601 602 701 702 800 801 802 803 804 901 902 904 905 906 907 908 909 920 921 922 923 RS232 INVALID ONLY 1 NO RND IN M RND RND COMP ALL SKIP MEMORY MENU ERR PROM CKS OP
22. sing the keys and press to return to the main menu press fefe If you have chosen SER select location of decimal point using press select Baud Rate Data Bits Stop Bits and parity in the same manner to set up another transducer press w 2 Select another memory B to I using the keys and press to return to main menu press If you have selected H O Select units of measure inlb ftlb etc using Note High Output devices usually produce an output voltage of approximately 1 2Volts This analogue voltage signal will not be exact and may not be linear If you are using a device that has a nominal 1Volt output we suggest that you multiply the span of your transducer by 2 5 to determine the new span setting Type in your new span press type in Serial Number press screen will indicate End of Set up press eno en Connect your high output device and select measure mode refer to instruction sheet for measure mode only Use an independent measuring device to apply a torque to the transducer and check the reading on the independent unit against the reading shown on the Auditor DC It will be necessary to return to the Edit Tx menu option and adjust the span setting until the two readings agree You may have to repeat the above procedure several times until your high output transducer is correctly calibrated PO Box 16460 Portland OR 97292 0460 503 254 6600 Fax 503 255 2615 www aimco global com Auditor DC I Il Manual
23. ss Note When selecting a threshold torque value the Auditor DC will ignore any torque which is below this value You cannot take another reading until the applied torque falls below this value type in amount of Dip press select Second Parameter using press Auditor DC II only If the set up and transducer has not been changed since the Auditor DC was last used you are now ready to take torque measurements Pressing after taking a series of readings will result in statistical information being displayed Range mean and standard deviation for the stored readings To return to measure mode press ff If you have selected Click Dip type in the amount of Dip to be sensed press You are now ready to take torgue measurements When finished press fe PO Box 16460 Portland OR 97292 0460 503 254 6600 Fax 503 255 2615 www aimco global com Auditor DC I Il Manual Note When taking readings you can change the set up parameters by pressing the up arrow Changing any of the set parameters will result in the Auditor DC prompting to erase all data To erase stored readings press To return to set up screens press fe Example You have been measuring in a right hand direction and you want to switch to left hand Press the up arrow twice change from right hand to left hand Screen will prompt to erase all data press to erase all stored readings and return to the measure screen Printing of stored readings from measure mo
24. st be a minimum of 30 samples To set this function From main menu Press then press 6 or press 6 Misc Press then press 6 or press 6 Software reset Press 5 times to access the Cpk Calculation screen Use the and arrow keys to access option 2 French Cpk CAM and press Press fe to confirm Screen will prompt End of set up Press fe to accept and exit or gt to edit Press fe to return to main menu Returning to Normal Cpk calculations is done as above selecting option 1 Normal Cpk no CAM For more information on Cp Cpk and CAM please refer to the glossary on page 23 PO Box 16460 Portland OR 97292 0460 503 254 6600 Fax 503 255 2615 www aimco global com 14 Auditor DC I Il Manual To Erase Stored Data and Set ups To Erase readings stored in measure mode From the main menu press 2 Measure then press Screen will prompt Erase Measure data press to erase data or press to ignore and continue PO Box 16460 Portland OR 97292 0460 503 254 6600 Fax 503 255 2615 www aimco global com 15 Auditor DC I Il Manual Printing To print details of set up or analysis of data To print readings taken in measure mode Connect Auditor DC to printer and switch printer on On Auditor DC Press Press fe Press right arrow then press 5 or press 5 Print Press then press or press Print Measure Auditor DC will print details of stored readings taken in measure mode with date tim
25. ternal pre amplifier giving an output signal level of typically 1 or 2 volts Collection of data by round taking one reading for each characteristic in turn Type of transducer with no pre amplifier or coding links but with the exact rated torque marked on the body A sequence of up to five rounds It is used to allow a collection sequence which is part vertical part horizontal Upper tolerance level of any reading This can equal but not exceed the PO Box 16460 Portland OR 97292 0460 503 254 6600 Fax 503 255 2615 www aimco global com 23 Value Min Torque Value No of Sub Groups Round Sample Standard Deviation Sub Group Threshold Torque Value Units of Measure Vertical Vertical plus Prompt Auditor DC I Il Manual torque rating of the transducer to be used Lower tolerance level of any reading Number used to allocate memory space in Auditor DC for a particular characteristic May be set in the range of 1 to 99 A sequence of characteristics to be collected either horizontally or vertically Each round has a name of up to 14 characters 8 if downloaded from the PC Individual torque reading Is a measure of the variation of the samples of a statistical group If a group of n values has a mean of x then its standard deviation is given by grouping of samples to enable analysis with an allowable range of 1 50 level of torque which a signal must rise above and then fall below to b