USER MANUAL 26" RADIANCE D HB
Contents
1. lii Tab 2 About This Manual Intended Use and Contraindications Touch Screen Option nonno Quick Startup Powering On The Unit First Time Users and Initial Test Tab 3 Connector Panel Tab4 Control naiai Service Menu Troubleshooting Tab 5 Drawing and Dimensions nnn Tab 6 D
2. in EEA EE APs EOE TR TUS P AE HARD HTT This product complies to the above standards only when used with the supplied medical grade power supply Power Supply BridgePower BPM150S24F06 AC Input 100 to 240 Volts at 50 to 60 Hz DC Output 24 volts at 6 25 amps Power Cord Use a hospital grade power cord with the correct plug for your power source Disconnect the power cord from the AC mains The power cord is the only recognized disconnect device The MEDICAL EQUIPMENT should be positioned so that its disconnect device is readily accessible The product should be powered from a center tapped circuit when used in the US at voltages over 120 volts Product is intended for continuous operation This product is energized from an external electrical power source for class 1 equipment It is the responsibility of the installer to test the product s earth ground to verify that it complies with the hospital local and national impedance requirements A ground post located on the back of the product may be used for the purpose of grounding the unit s chassis Any such ground must be installed in accordance with applicable electrical codes The ground post is shown on the mechanical drawing found on page 2 Recycling Follow local governing ordinances and recycling plans regarding the recycling or disposal of this equipment 1 Declarations of Conformity
3. setup and operation of the display Depending on the model and options that were purchased some of the features and options in this manual may not apply to the display you are using A numbered tab on the side of the page denotes the beginning of a section The functional descriptions in this manual are representative of Part Numbers 90R0054 Firmware BIOS 58M0003 Version A and later Manual Part Number 60G0440 Rev C Intended Use and Contraindications Intended Use This monitor is intended for use in a medical environment to display high quality video and graphic images Contraindications The monitor may not be used in the presence of flammable anesthetics mixture with air oxygen or nitrous oxide No part of this product may come in contact with a patient Never touch the product and a patient at the same time For mission critical applications we strongly recommend that a replacement unit be immediately available Quick Startup Powering On The Unit Connect the power supply to the display via the power plug Plug in the AC adapter Connect a video source to the display Apply power to the peripheral device then to the display The NDS logo is displayed followed shortly by video First time users and initial test Visually Flat Panel LCD images will look crisper than those of a traditional CRT For the same reason live video may appear a little blocky Users not familiar with the image differences should familia
4. given block is 2 then the second and third digits cannot be greater than 5 The port address is set the same way as the IP address was set The port address may be set to any value from 0 to 65535 Note An IP address and a port address may be obtained from your Network Administrator D From the Service Menu press Next DVI to select Color Standard then press Enter SDI to open the Color Standard Menu e The highlighted button in the Color Standard Menu is the current color standard To change color standard press the Next DVI button until the desired standard is highlighted Pressing the Next DVI button when BT 709 is highlighted moves the highlight to Bypass When the desired standard is highlighted press the Select and Exit SDI button to select the standard close the Color Standard Menu and return to the Service Menu Color Standard Troubleshooting Section Black Screen If the LED in the front lower right corner is orange then the display is in Power Save Mode Connect a DVI signal to the DVI connector If an image does not appear press the DVI button twice the label under the DVI button should turn blue and an image should be displayed and the LED will turn blue If an image is not displayed turn the display Off and On If the NDS logo appears then the display is working properly Searching A Searching message in the lower right hand corner of the display means that the video source is not bein
5. in the electromagnetic environment specified below The customer or the user of the product should assure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Portable and mobile RF communications equipment should be Conducted RF 3 Vrms 3 Vrms used no closer to any part of the product including cables than IEC 61000 4 6 150 kHz to 80 MHz the recommended separation distance calculated from the equation applicable to the frequency of the transmitter 3 V m Recommended separation distance Radiated RF 80 MHz to 2 5 GHz 3 V m IEC 61000 4 3 d 12 d 124 80 MHz to 800 MHz d 234P 800 MHz to 2 5 GHz where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation Distance in metres m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol SY NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless
6. installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e _ Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult your dealer or an experienced radio TV technician for help Accessory equipment connected to this product must be certified according to the respective IEC Standards i e IEC 60950 1 for data processing equipment and IEC 60601 1 for medical equipment Furthermore all configurations shall comply with the system standard IEC 60601 1 1 Anyone who connects additional equipment to the signal input part or signal output part configures a medical system and is therefore responsible that the system complies with the requirements of system standard IEC 60601 1 1 Whoever is responsible for securing the product to a system needs to insure that the mounting equipment used with this product complies to IEC standard 60601 1 If in doubt consult the technical services department or your local representative Legal Statement NDS sells its products through other medical device manufacturers distributors and resellers and therefore purchasers of this NDS product should consult w
7. telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the product is used exceeds the applicable RF compliance level above the product should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as re orienting or relocating the product b Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m 15 16 EMC Tables Recommended separation distances between portable and mobile RF communications equipment and the product The product is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the product can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the product as recommended below according to the maximum output power of the communications equipment Rated maximum output Separation distance in meters according to frequency of transmitter power W of transmitter 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz 0 01 0 12 0 12 0 23 100 12 12 23 For transmitters rated at a m
8. ARE HEREBY EXPRESSLY EXCLUDED AND DISCLAIMED NDS its suppliers and or distributors are not liable directly or by way of indemnity for any special incidental consequential punitive exemplary or indirect damages including but not limited to alleged damages for delayed shipment non delivery product failure product design or production inability to use such products or services loss of future business lost profits or from any other cause whatsoever in connection with or arising from the purchase sale lease rental installation or use of such NDS products these terms and conditions or with respect to any the terms of any agreement which incorporates these terms and conditions SOME JURISDICTIONS DO NOT ALLOW EXCLUSIONS AND DISCLAIMERS OF CERTAIN WARRANTIES OR LIMITATIONS OF LIABILITY SO THE LIMITATIONS AND OR EXCLUSIONS SET FORTH HEREIN MAY NOT APPLY IN THAT EVENT LIABILITY WILL BE LIMITED TO THE GREATEST EXTENT PERMITTED BY LAW IN THE SUBJECT JURISDICTION The information provided in this document including all designs and related materials is the valuable property of NDS and or its licensors and as appropriate they reserve all patent copyright and other proprietary rights to this document including all design manufacturing reproduction use and sales rights thereto except to the extent said rights are expressly granted to others About This Manual This manual is designed to assist the user with proper installation
9. CK SHIELD T M D S CLOCK 23 T M D S DATA 1 24 T M D S CLOCK T M D S DATA 1 3 SHIELD Cable Bend Radius We recommend that the bend radius of metallic cables be no less than 2 5 inches 63 mm or 7 times the diameter of the cable whichever is greater Sharper bends may damage the cable and or degrade the video signal RJ 45 Connector and Pin Out Pin No mm Notes Description TX D1 Transmit data EN 1 3 Bi directional data or Bi directional data or Bi directional data or 5 Volt Connector and Pin Out Mating Connector CUI P N PP 015 Power Connector and Pin Out Viewable Diagonal inches Maximum Luminance cd m typical 500 Stabilized 1920 0 178 178 1000 1 20 00 70W 79W 18 8 lbs 8 5 kg QURE 20 to 8596 6 600 ft 2 000 m 219 8910 20 to 50 C 310 23 5 to 85 33 000 ft 10 000 m B1 709 Luminance Native Resolution Dot Pitch mm Vertical Viewing Angle Horizontal Viewing Angle Contrast Ratio nominal 3G SDI Input signal level DC Power Consumption nominal AC Power Consumption nominal Display Weight Environmental Operating Temperature Operating Humidity non condensing Operating Altitude Storage Temperature Transport Temperature Storage Humidity non condensing Transport Humidity non Conden
10. D Press the 3G button to select the 3G SDI input the 3G legend will be illuminated by a blue LED Only the selected input is illuminated If a signal is connected to the selected input the LED in the lower front right corner of the display will turn blue If no signal is applied to the selected input the LED will turn orange when the display goes into Power Save Mode Service Menu The Service Menu allows you to set the display s IP Address or select the Color Standard to be used Setting the Color Standard is described on the following page To access the Service Menu press and hold both the SDI and the DVI buttons during power up The Service Menu should appear on a black background with its IP Address button high lighted Press the Next DVI button to select Color Standard or End Pressing the Next button on End moves the cursor back to IP Address To exit the Service Menu select End then press the Enter SDI button with the IP Address button highlighted press the Enter button to open the IP Address Menu 9 IP Address The IP address consists of 4 blocks of 3 digits each each block may have a value of 0 to 255 Press the Next DVI button until the first digit of the first IP address block is highlighted then press the SDI button to set the first IP address digit Press Next to select the next digit then press to set it Continue until all the IP address digits have been entered Note If the first digit in a
11. FCC and Council Directives of European Standards This device complies with Part 15 of FCC rules and 93 42 EEC and 2007 47 EC of the Council Directives of European Standards Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesirable results 1 Use the attached specified cables with the color product so as not to interfere with radio and television reception Use of other cable and adapters may cause interference with other electronic equipment 2 This equipment has been tested and found to comply with the limits pursuant to FCC part 15 and CISPR 11 This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications IEC This equipment has been tested and found to comply with the limits for medical devices to the IEC 60601 1 2 These limits are designed to provide reasonable protection against harmful interference in a typical medical installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to other devices in the vicinity FCC Council Directives of European Standards and IEC There is no guarantee that interference will not occur in a particular
12. ICAL IMAGING 26 RADIANCE D HB High Definition Korm ORADIA NCE D USER MANUAL 2012 NDS Surgical Imaging LLC All rights reserved Information in this document has been carefully checked for accuracy however no guarantee is given to the correctness of the contents This document is subject to change without notice NDSsi provides this information as reference only Reference to products from other vendors does not imply any recommendation or endorsement This document contains proprietary information protected by copyright No part of this manual may be reproduced by any mechanical electronic or other means in any form without prior written permission of NDSsi All trademarks are the property of their respective owners Table of Contents Tab 1 Warnings and Cautions li Recycling ii Declarations of Conformity 1 Legal Statement
13. VI Connector Pin Out Cable Bend Radius RJ 45 Pin Out 5 Volt Connector and Pin Out Power Connector and Pin Out Tab 7 Specifications Video Inputs Video Formats Cleaning and Disinfecting Instructions Electromagnetic Compatibility EMC Tables Warnings and Cautions This symbol alerts the user that important information regarding the installation and or operation of this equipment follows Information preceded by this symbol should be read carefully in order to avoid damaging the equipment This symbol warns user that un insulated voltage within the unit may have sufficie
14. aning materials are listed below Remove residual detergent by wiping all exterior surfaces with a lint free cloth dampened with distilled water Disinfecting Disinfect the unit by wiping all exterior surfaces with a lint free cloth dampened with 8096 Ethyl Alcohol Allow the unit to air dry IN cautions Do not allow liquids to enter the interior of the unit and do not permit exterior surfaces to come into contact with unacceptable solvents such as those listed below as severe damage to the unit may result Acceptable Cleaning Materials Vinegar distilled white vinegar 5 acidity Ammonia based glass cleaner Acceptable Disinfecting Material Ethanol 80 by volume Unacceptable solvents MEK Methyl Ethyl Ketone Toluene Acetone Note The acceptable cleaning and disinfecting materials listed above have been tested on NDS products and when used as directed do not harm the product s finish and or its plastic components 12 N Electromagnetic Compatibility EMC Tables All medical electronic devices must conform to the requirements of IEC 60601 1 2 Precautions adherences to the EMC guideline information provided in this manual and verification of all medical devices in simultaneous operation are required to ensure the electromagnetic compatibility and co existence of all other medical devices prior to a surgical procedure The EMC tables on next 3 pages are provided for your reference 14 EMC Tables Guidanc
15. aximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people Asia Pacific Sea Fort Square Center Bldg 8F 2 3 12 Higashi Shinagawa Shinagawa ku Tokyo 140 0002 Japan Tel 81 3 5781 8292 Email info ndssi jp Furope Nijverheidcentrum 28 2761 JP Zevenhuizen ZH The Netherlands Tel 31 180 63 43 56 Email info ndssi nl d Corporate Headquarters 5750 Hellyer Avenue San Jose CA 95138 United States USA Tel 408 776 0085 Toll Free 866 637 5237 Email info ndssi com SURGICAL IMAGING www ndssi com 6060440
16. e and manufacturer s declaration electromagnetic emissions The product is intended for use in the electromagnetic environment specified below The customer or the user of the product should assure that it is used in such an environment Compliance Emissions Electromagnetic environment guidance The product uses RF energy only for its internal function Therefore its domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes HF emissions Group 1 RF emissions are very low and are not likely to cause any interference CISPR TT in nearby electronic equipment RF emissions Class A The product is suitable for use in all establishments including Harmonic emissions Not Applicable IEC 61000 3 2 Voltage fluctuations flicker emissions IEC 61000 3 3 Not Applicable Guidance and manufacturer s declaration 211 electromagnetic immunity The product is intended for use in the electromagnetic environment specified below The customer or the user of the product should assure that it is used in such an environment Electromagnetic environment guidance Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 96 Mains power quality should be that of a typical commercial or hospital environment Mains power quality shou
17. g detected Verify that the video source is functioning correctly and that the cable connecting it to the display is not damaged LED is Orange and Blinking This condition may be caused by low voltage or current delivered to the display If your are using an AC or DC extension cord Verify that it is connected properly and that its conductors are large enough to deliver to deliver sufficient current to operate the display The AC and DC power consumption values are listed in the Specifications table on page 10 Drawing and Dimensions 26 73 678 9 13 22 335 9 ENDS MOUNTING HOLES 4x 50mm 200 3 94 mnm 10X 100 amm gs _ JENSEN eo EE Wit B The display shown above has a standard 100mm VESA mount allowing convenient system integration of the vertically positioned display We recommend that the installation be performed by a qualified technician Please contact your provider s service department for installation assistance Failure to properly secure the display to the mounting bracket may be hazardous DVI Connector Pin Out DVI D Digital SIGNAL SIGNAL T M D S DATA 2 HOT PLUG DETECT T M D S DATA 2 T M D S DATA 0 T M D S DATA 2 4 T M D S DATA 0 SHIELD T M D S DATA 4 T M D S DATA 0 5 SHIELD T M D S DATA 4 T M D S DATA 5 DDC CLOCK T M D S DATA 5 DDC DATA T M D S CLO
18. ith the entity through which this product was originally purchased regarding the terms of any applicable product warranties provided by such entity if any NDS neither assumes nor authorizes any person to assume for it any other liabilities in conjunction with and or related to the sale and or use of its products To ensure proper use handling and care of NDS products customers should consult the product specific literature instruction manual and or labeling included with the product or otherwise available Customers are cautioned that system configuration software the application customer data and operator control of the system among other factors affect the product s performance While NDS products are considered to be compatible with many systems specific functional implementation by customers may vary Therefore suitability of a product for a specific purpose or application must be determined by the consumer and is not warranted by NDS NDS SPECIFICALLY DISCLAIMS ALL WARRANTIES OF ANY KIND WHETHER EXPRESS IMPLIED AND OR STATUTORY INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY FITNESS AND OR OF SUITABILITY FOR A PARTICULAR PURPOSE AND NON INFRINGEMENT WITH RESPECT TO ALL NDS PRODUCTS OR SERVICES ANY AND ALL OTHER WARRANTIES REPRESENTATIONS AND OR GUARANTEES OF ANY TYPE NATURE OR EXTENT BE IT IMPLIED EXPRESS AND OR WHETHER ARISING UNDER OR AS A RESULT OF ANY STATUTE LAW COMMERCIAL USAGE CUSTOM TRADE OR OTHERWISE
19. ld be that of a typical commercial or hospital environment Mains power quality should be that of a typical commercial or hospital environment If a dips or an interruption of mains power occurs the current of the product may be dropped off from normal level it may be necessary to use uninterruptible power supply or a battery Not applicable Compliance level 6 kV contact 8 kV air 2 kV for power supply lines 1 kV line s and neutral 5 96 Ur gt 95 96 dip in Uy for 0 5 cycle 40 96 Ur 60 96 dip in Uy for 5 cycles 70 96 Ur 30 96 dip in Uy for 25 cycles 5 Ur gt 95 dip in Uy for 5s Not applicable IEC 60601 test level 6 kV contact 8 KV air 2 kV for power Supply lines 1 kV line s and neutral 5 96 Ur gt 95 dip in Uy for 0 5 cycle 40 96 Ur 60 96 dip in Uy for 5 cycles 70 96 Ui 30 96 dip in Uy for 25 cycles 5 96 Ur gt 95 96 dip in Ur for 5s 3 A m Immunity test Electrostatic discharge ESD IEC 61000 4 2 Electrical fast transient burst IEC 61000 4 4 Surge IEC 61000 4 5 Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 Power frequency 50 60 Hz magnetic field IEC 61000 4 8 NOTE Uis the a c mains voltage prior to application of the test level EMC Tables Guidance and manufacturer s declaration electromagnetic immunity The product is intended for use
20. nt magnitude to cause electrical shock Therefore it is dangerous to make contact with any part inside the unit To reduce the risk of electric shock DO NOT remove cover or back There are no user serviceable parts inside Refer servicing to qualified service personnel This symbol cautions the user that important information regarding the operation and or maintenance of this equipment has been included Information preceded by this symbol should be read carefully to avoid damage to the equipment This symbol denotes the manufacturer ec This symbol denotes the manufacturer s European Community representative To prevent fire or shock hazards do not expose this unit to rain or moisture Also do not use this unit s polarized plug with an extension cord receptacle or other outlets unless the prongs can be fully inserted The product is designed to meet the medical safety requirements for a patient vicinity device This equipment system is intended for use by healthcare professionals only Safety Compliance tim This product is T U V approved WITH RESPECT TO ELECTRIC SHOCK FIRE AND MECHANICAL HAZARDS ONLY IN ACCORDANCE WITH UL 60601 1 CAN CSA C22 2 NO 60601 1 and ANSI AAMI ES60601 1 Safety Compliance This product meets the requirements of EN 60601 1 so as to conform to the Medical Device Directive 93 42 EEC and 2007 47 EC general safety information Safety and EMI Compliance GB9254 GB4943 and GB17625 pa HH HA
21. rize themselves before utilization in a critical application and determine its usability It is recommended that first time users view the display next to a CRT to familiarize themselves with any subtle differences in viewing quality Connector Panel 3G SDI CONTROL DVI OUT oV OUT DVI IN IN OUT DC ZW Q 2 Po I omme O Ou y Notes The connector panel is shown as it appears with the display laying on its face The 3G SDI module is factory installed DVI OUT and 3G SDI OUT are always active when the display is powered on The RJ 45 connector is used to install BIOS upgrades The 5V DC OUT provides power for auxiliary devices whose current draw is less than 1 Amp See page 9 for pin out and mating connector details The ZW connector is for future use Por els O CY ON OFF SWITCH po O O 2 i 22 E MM M oe N 71 Electrical Symbols Equipotentiality This symbol appears next to the display s potential equalization connector ground post Closed On Switch 0 Open Off Switch C This symbol appears on the open or off side of the display s rocker switch e This symbol appears on the closed or on side of the display s rocker switch Control The display accepts a DVI input or a 3G SDI input Press the keypad s DVI button to select the DVI input the DVI legend will be illuminated by a blue LE
22. sing Storage Altitude Specifications Notes a Specifications are subject to change without notice Contact factory for current specifications b Brightness shown is without an A R filter installed c BridgePower BPM150S24F06 Input AC 100 240V 50 6072 2 5A Max Output 24VDC 6 25A 10 DVI Supported Resolutions Signal Parameter Supported Range Active Resolution 640 x 480 min to 1920 x 1200 max Horizontal x Vertical Refresh Rate 23 98 Hz up to 85 HZ Vertical Frequency Pixel Clock 25 MHz up to 165 MHz Pixel Frequency The DVI D input can automatically detect any valid digital DVI signal within the resolution vertical refresh and pixel clock ranges specified in the table above Signals outside of any of the specified ranges may not be supported SDI Supported Resolutions Horizontal Vertical Vertical Horizontal Vertical Vertical Resolution Resolution Frequency Resolution Resolution Frequency pixels lines hz pixels lines HZ Video and Graphics Inputs Connector Type 3G SDI BNC 75 Ohm terminated 11 Cleaning and Disinfecting Instructions N Prior to cleaning and surface disinfection the unit should be turned OFF and disconnected from its power source Cleaning Thoroughly wipe all exterior surfaces with a lint free cloth that has been dampened with an acceptable cleaning agent Acceptable cle