1. 8557155B DSF Figure 4 Wiring the Touchpad to Concord and Concord Express Panels Advent Panels 1 2 Splice the touchpad wiring to the panel SuperBus wir ing harness as shown in Figure 5 Wire multiple touch pads in parallel If desired connect an optional hardwire switch to the yellow wires on the touchpad wiring harness Wire a 2K ohm EOL resistor 49 467 in series with normally closed switches and in parallel with normally open switches see Figure 5 Note The optional touchpad hardwire input must be added to panel memory See the Advent panel Installation Instructions for setting the configuration Mounting the Touchpad SS 3 Insert the touchpad wiring harness connector onto the pins located on the rear of the unit Make sure the yel low wires are to the left see Figure 5 TO ADDITIONAL SUPERBUS TOUCHPADS AND OR MODULES J PANEL SUPERBUS WIRING HARNESS 49 462 WHITE BUS B GREEN BUS A Ls RED 412 VDC gt BLACK GND OPTIONAL N O SWITCH WITH MAGNET SPLICE 2K OHM Connect Shield EOL RESISTOR to Earth Ground OPTIONAL sH ELDED 7 N C SWITCH CABLE WITH MAGNET t OEEEEETT e TAB X SLOT 3 TOUCHPAD WIRING HARNESS 49 430 x Z x Z x Z ma 8543109C DSF Figure 5 Wiring the Touchpad to Advent Panels Mounting the Touchpad PEE aaa 1 Align the slots on the touch
2. Changes or modifications not expressly approved by Interactive Tech nologies Inc can void the user s authority to operate the equipment FCC Part 15 Class A This equipment has been tested and found to comply with the limits for a class A digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environ ment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interfer ence in which case users will be required to correct the interference at their own expense FCC Part 15 Class B This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television rec
3. 5 describe actions you can take to correct problems you may experience when connecting bus devices to each of the different panels The touchpad doesn t 1 Check for correct wiring connec Table 3 UltraGard Troubleshooting power up no display tions at the touchpad and panel s and no beeps when terminals Problem Action Solution buttons are pressed 2 Make sure the panel battery is All touchpads display 1 Disconnect all touchpads connected correctly and that the 1 OFF but they don t except the original Set the panel transformer is plugged in work or won t enter panel mode switch to 3 Make sure the panel transformer program mode PROGRAM enter the is not plugged into an electrical install code and switch outlet controlled by a switch back to RUN Relocate the transformer to an 2 Assign a different unit num unswitched outlet if necessary ber to each touchpad using The touchpad display 1 Check the touchpad display con the procedure outlined in appears blank but trast setting It may be set to 0 no this document beeps sound when display The touchpad displays the 1 Turn off the panel power buttons are pressed message BUS FAIL UNIT switch Check the wiring at The touchpad displays 1 Check for correct bus wiring con N N unit number of all bus devices and correct a flashing star nections green and white wires failed bus device where necessary indicating a trouble at t
4. Q Concord software versions 1 0 1 6 SuperBus 2000 2 x 20 LCD Alphanumeric Touchpad ITI Part No 60 803 amp 60 809 Installation Instructions Installation Guideline RS n For the maximum number of bus devices and touchpads per panel see Table 1 Table 1 Maximum Bus Devices Per Panel Panel Maximum Bus Devices Advent 62 UltraGard 8 Concord 16 Concord Express 4 Q Do not exceed the total panel output power when using panel power for bus devices touchpads and hardwired sensors that require it see specific panel Installation Instructions Maximum current draw from the touchpad is 120 mA Minimum current draw from the touchpad when the panel is operating only on backup battery is 15 mA Mount the touchpad in an environmentally controlled area 32 to 140 F 0 to 60 C When using the optional touchpad hardwire input use only shielded wire 22 gauge or larger and do not exceed the maximum wire length limits in Table 2 between the touchpad and detection device O oO OO Note Shield wire must be connected to earth ground Table 2 Hardwire Input Wire Length Limits eE UT Max Wire Length 18 shielded 1000 Feet 22 shielded 350 Feet Q When mounting the touchpad back plate allow a 1 inch clearance on all sides since the touchpad is larger than the back plate Use 4 conductor 22 gauge or larger stranded wire from the t
5. sec Enrolled tion Powering up Advent Panels in this document SuperBus 2000 2 x 20 LCD Alphanumeric Touchpad Specifications Specifications Touchpad Panel Compatibility Touchpad Part No Compatible Panel s 60 803 04 Concord Concord Express 60 809 03 Custom Concord Versions 60 809 03 SEC Security Pro UltraGard and Custom Versions 60 803 03 UltraGard and Custom Versions 60 803 01 Advent Power Requirements 12 VDC nominal 120 mA maximum from panel Display 2 line 40 character 2 x 20 backlit alphanumeric liquid crystal Zone Input One supervisable hardwire zone input Data I O 4 wire ITI SuperBus 2000 auto addressing digital data bus Storage Temperature 30 to 140 F 34 to 60 C Operating Temperature 32 to 140 F 0 to 60 C Maximum Humidity 90 45 relative humidity non condensing Listings see note UL 985 Household Fire Warning System Units UL 1023 Household Burglar Alarm System Units UL 1610 Central Station Burglar Alarm Units Commercial Burglary CSFM California State Fire Marshall Note See specific panel nstallation Instructions for complete UL installation requirements for the system you are installing Dimensions 4 60 x 7 75 x 1 2 H x W x D Chassis Material High Impact ABS plastic Case Color Belgian gray with gray imprints Notices SS n FCC Part 15 Information to the User
6. trans former Alphanumeric touchpads show SCANNING BUS DEVICES then a date and time display 3 Verify correct operation by pressing The display should show the current system status Note If after pressing El the touchpad does not display the current system status see Troubleshooting Powering up Concord Panels with Software Versions 1 0 1 6 First Touchpad 1 Verify that all wiring between the panel and touchpad is correct 2 Check the unit number DIP switches on all other bus devices ESM HIM etc and make note of their respective unit numbers Note Touchpads default to unit number 001 when first installed If possible leave this unit number open If unit number 001 is not available or there are multiple touchpads installed see the section Additional Touchpads below 3 Connect the panel battery and plug in the panel trans former Alphanumeric touchpads show SCANNING BUS DEVICES then a date and time display 4 Verify correct operation by pressing J The display should show the current system status Note If after pressing the touchpad does not display the current system status see Troubleshooting Additional Touchpads 1 Verify that all wiring between the panel and touchpad is correct 2 Check the unit number DIP switches on other bus devices ESM HIM etc and make a note of their respective unit numbers 3 Connect the panel battery and plug in the p
7. SuperBus 2000 2x 20 LCD Alphanumeric Touchpad Document Number 466 1632 Rev B September 2000 Product Summary The ITI SuperBus 2000 2 x 20 LCD liquid crystal dis play Alphanumeric Touchpad gives you complete on site system programming and operation control of a compatible security system see the section Specifications A two line 40 character display provides visual system status messages The display identifies any programmed location allowing the user to determine where an alarm trouble or open sensor condition exists Other features include Q Touchpad buttons that light up after the first button press and remain lit until about 15 seconds after the last button press Q Adjustable display contrast and backlighting Q Built in hardwire input can be supervised with EOL resistor in SuperBus 2000 panels QO Built in door which covers right side buttons 60 809 only SuperBus 2000 Panels vs SuperBus Panels SuperBus 2000 panels assign module unit numbers automatically when the panel is powered up This eliminates manually setting unit numbers and the chance of identical unit number conflicts SuperBus 2000 Panels QO Advent Q Concord software versions 2 0 and newer Q Concord Express SuperBus panels communicate with SuperBus 2000 modules but require the module unit number to be set manually Touchpads automatically default to unit number 001 SuperBus Panels Q UltraGard
8. anel trans former Alphanumeric touchpads show SCANNING BUS DEVICES then a date and time display Deleting Touchpads Unit Numbers from Panel Memory O 4 Ata touchpad press and hold the D and 6 buttons together for at least 2 seconds The display should show DA n where n is the current unit number 000 015 for the touchpad Note At this time the touchpad is in configuration mode and no longer communicating with the panel The system may immediately indicate a bus failure Ignore the fail ure and continue with the procedure The failure will clear after the unit number has been successfully changed 5 Press HA The display shows ENTER _ 6 Enter an unused three digit unit number 000 015 then press HA The display shows DA n where n is the new unit number for the touchpad 7 Press 4 to exit from the configuration mode 8 Repeat steps 4 8 for all connected alphanumeric touchpads Note If the new unit number for the touchpad was previ ously added learned by the panel communication between the touchpad and the panel begins immedi ately However if the new unit number for the touch pad has never been added learned by the panel continue with step nine 9 Force the panel to scan bus devices Q For systems where this is the only installed touch pad remove the panel AC power and backup bat tery power then re apply power Q For systems with more than one touchpad go to another syst
9. battery and turn off the power switch 2 Connect all bus device wiring to the panel including the wiring that was disconnected in step one of the first touchpad installation but make sure no new touchpads are connected to their wiring harnesses yet 3 Verify that all wiring at the panel and at the added touchpad wiring harnesses are correct but do not connect any touchpads to their wiring harness Apply power to the panel turn on the power switch 5 Set the RUN PROGRAM switch to PROGRAM Existing previously installed touchpad s display PROGRAM MODE Or The display shows ENTER CODE or 1 OFF 1 blink ing indicating you need to enter the install code After entering the install code existing touchpads display PROGRAM MODE Note After entering the install code to get into program mode the panel allows you to switch between RUN and PROGRAM mode for 1 hour without re entering the code 6 At an existing touchpad press BYPASS or STATUS until the display shows TOUCHPAD OPTIONS 7 Press COMMAND and the display shows UNIT NUMBER 8 Press COMMAND existing touchpads will display DA 00N where N is the unit number 0 7 Make a note of this touchpad unit number 9 Check the unit numbers of all other existing touchpads and write them down 10 Check the unit number DIP switches on other bus devices ESM HIM etc and make a note of their respective unit numbers 11 Connect the wiring harness to one new to
10. bers before beginning all other panel programming Q Other bus devices with device unit number DIP switches ESM HIM etc must be set to the desired unit number before applying power and entering program mode Power Up and Bus Communication PEE Powering Up UltraGard Panels First Touchpad 1 Disconnect all bus device wiring from the panel except for the touchpad location closest to the panel 2 Verify that all wiring at the panel and touchpad wiring harness is correct 3 With the panel power switch off connect the panel bat tery and plug in the panel AC power transformer Set the panel RUN PROGRAM switch to RUN 5 Turn on the panel power switch 6 Put the touchpad into the manual configuration mode by pressing and holding the touchpad D and B buttons until the display shows DA 001 unit number 001 7 Set the panel RUN PROGRAM switch to PROGRAM and the display should read PROGRAM MODE 8 Verify correct operation by pressing STATUS or BYPASS The display should show a different menu item for each button pressed If your installation only calls for one alphanumeric touch pad you may proceed with other system programming If you have more alphanumeric touchpads to connect and assign device addresses use the following procedure before proceeding with any other system programming SuperBus 2000 2 x 20 LCD Alphanumeric Touchpad Additional Touchpad 1 Disconnect the panel AC power transformer backup
11. em touchpad and enter 8 installer CODE default 4321 0 O The display shows SCANNING BUS DEVICES then a date and time display 10 Exit the program mode The touchpad and all other bus devices should operate correctly and any bus failures should be cleared Note If the panel still indicates a bus failure the panel may have previously learned a unit number that is no longer used by any bus device Delete the unused unit number 11 Verify correct operation by pressing 4 The display should show the current system status Note If after pressing E l the touchpad does not display the current system status see Troubleshooting Powering Up Advent Panels New Installations 1 Verify that all wiring between the panel and touchpad is correct 2 Connect the panel battery and plug in the panel trans former The alphanumeric touchpad should display Security is Off or any other programmed text Note If the touchpad does not display anything or displays Touchpad Not Enrolled see Troubleshooting Existing Installations 1 Verify that all wiring between the panel and touchpad is correct 2 Connect the panel battery and plug in the panel trans former 3 Atan existing touchpad press 8 to select SYSTEM MENU Press 0 to select ENTER PROGRAM MODE 5 Enter your install access CODE 0123 is default 6 Enter item number MBIO to add bus devices All installed devices are automa
12. eption which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the affected equipment and the panel receiver to separate outlets on different branch circuits 0 OODD Consult the dealer or an experienced radio TV technician for help Interactive Technologies Inc 2266 Second Street North North Saint Paul MN 55109 2900 T 651 777 2690 F 651 779 4890 1 800 777 1415 www ititechnol ogies com JIC Security Automation Fire Protection Access Control aninterlogigs company 2000 Interactive Technologies Inc an Interlogix company Interlogix is a trademark of Interlogix Inc ITI SuperBus Advent UltraGard and Security Pro are registered trademarks of Interactive Technologies Inc Concord is a trademark of Interactive Technologies Inc SuperBus 2000 2 x 20 LCD Alphanumeric Touchpad
13. ews 5 Cuta hole in the wall where the wire access hole was marked to pull your cable through MOUNTING SLOTS m BOI E O t OPENING FOR CONNECTOR a OPENING Ve i a a 2 A LOOSEN BOTTOM SCREWS ME 90100AB DSR Figure 1 Touchpad Mounting Slots To mount the touchpad in a gang box 1 Separate the mounting bracket from the back plate by loosening the two bottom screws and unlatching the tabs from the mounting slots see Figure 1 2 Line up the gang box mounting holes with the holes on the gang box see Figure 2 3 Secure the back plate to the gang box with panhead screws Note f Do not overtighten screws or the back plate may bind and prevent the touchpad from mounting properly WALL MOUNTING HOLES X4 BACK PLATE MOUNTING TABS X3 WIRE D access 0 HOLE ts 27 LI L J GANG BOX MOUNTING HOLES X2 3101G02B DS4 Figure 2 Back Plate and Mounting Holes Wiring Wiring consists of connecting the touchpad wiring harness to the panel terminals You may also connect an optional hardwire sensor to the touchpad hardwire input wires Before You Begin 1 Disconnect the panel AC power transformer and backup battery turn off power switch on UltraGard panels 2 Runa 4 conductor 22 gauge wire cable from the panel to the touchpad location 3 Splice the 4 conductor cable wires to the matching col ored wires located on the touchpad wiri
14. he touchpad and panel 2 Assign a different unit num condition and the terminals ber to each touchpad using system doesn t 2 Make sure the touchpad unit the procedure in this docu respond to commands number is set to a number ment from the touchpad different from all other bus device 3 Set the panel mode switch to unit numbers If necessary PROGRAM then back to change the touchpad unit number RUN Concord panels with software The panel reports a trouble 1 Change the unit number on Veron ORES aly condition on the touchpad the new bus device to an loop unused unit number Turn power OFF then ON Set the mode switch to PRO 2 GRAM then back to RUN Table 5 Advent Troubleshooting 2 Turn off the panel power Problem Action Solution switch Check and correct the touchpad wiring The touchpad display 1 Check that the panel is not in the 3 The panel must learn the seems stuck in the program mode of operation hardwire loops again when a program mode o unit number is The touchpad displays 1 Check that the wiring connector CAIME SEERA REE EEE Any is plugged into the back of the error message or touchpad appears dead and 2 Check for incorrect wiring does not respond to opens or shorts button presses 3 Check panel power 4 From another touchpad enter program mode and verify touch pad is enrolled The touchpad displays 1 Perform the procedure for Exist Touchpad Not ing Installations under the
15. ional hardwire switch to the yellow touchpad wires as shown in Figure 4 Concord Express Systems Wire a 2K ohm EOL resis tor 49 467 in series with normally closed switches and in parallel with normally open switches see Figure 4 SuperBus 2000 2 x 20 LCD Alphanumeric Touchpad Wiring CC OOO Concord Systems with software version 2 0 or newer Wire a 2K ohm EOL resistor 49 467 in series with normally closed switches and in parallel with normally open switches see Figure 4 Concord Systems with software versions 1 0 1 6 This switch must be unsupervised and a resistor must not be used Note The optional touchpad hardwire input must be added to panel memory See the Concord Concord Express panel Installation Instructions for setting the configuration 3 Insert the touchpad wiring harness connector onto the pins located on the rear of the unit Make sure the yel low wires are to the left as shown PANEL TERMINALS 12V BUS BUS OPTIONAL GND BUS A B N O SWITCH WITH MAGNET ee HHAH lt q WHITE 2K OHM ma GREEN EOL RESISTOR lt lt RED Concord 2 0 or later and Concord Connect Shield BLACK Express panels to Earth Ground S gt gt Po OPTIONAL SHIELDED N C SWITCH CABLE WITH MAGNET YELLOW a NOT 4 USED TAB SLOT 3 TOUCHPAD WIRING HARNESS 49 430 S T L T Pi T pi s
16. ng harness Find your panel in the next section for specific wiring instructions SuperBus 2000 2 x 20 LCD Alphanumeric Touchpad Wiring Panels UltraGard Panels 1 Connect the touchpad wiring to the panel terminals as shown in Figure 3 Wire multiple touchpads in parallel If desired connect an optional hardwire switch to the yellow touchpad wires as shown in Figure 3 unsuper vised in UltraGard systems Note The optional touchpad hardwire input must be added to panel memory See the UltraGard panel Installation Instructions or Reference Manual for setting the con figuration Insert the touchpad wiring harness connector onto the pins located on the rear of the unit Make sure the yel low wires are to the left CONTROL PANEL DC BUS BUS OUT A B GND kal kg kg Es OPTIONAL SWITCH t BLACK WITH MAGNET lt _ WHITE Not to be used in UL listed installations GREEN RED Connect Shield To Earth Ground il S NWN SHIELDED CABLE YELLOW E EEn NOT 4 USED TAB SLOT 3 WIRING HARNESS 49 430 W g Z LF T J 8557148B DS4 Figure 3 Wiring the Touchpad to UltraGard Panels Concord Concord Express Panels 1 Connect the touchpad wiring to the panel terminals as shown in Figure 4 Wire multiple touchpads in parallel If desired connect an opt
17. ouchpad to the control panel Follow the wire length limits outlined in the specific panel Installation Instructions between the touchpad and control panel Tools Needed SL The following must be observed in UL installations Q The touchpad hardwire input must not be used for fire alarm initiating devices Q Only UL listed devices may be connected to the touch pad hardwire input Q The touchpad hardwire input can be configured for normally closed or normally open protection devices Q For UL installations with UltraGard and Concord soft ware versions 0 1 6 panels do not use the touchpad hardwire input Tools Needed SS Drill with bits Screwdrivers 6 screws and anchors included Panhead screws for a gang box installation DODDO Saw or utility knife for cutting wallboard Note Do not use screws larger than 6 or the touchpad will not seat properly onto the back plate Installation y The touchpad can be installed on a wall or in a gang box To mount the touchpad on a wall 1 Separate the mounting bracket from the back plate by loosening the two bottom screws and unlatching the tabs from the mounting slots see Figure 1 2 Place the back plate on the wall and mark the four mounting holes and the wire access hole see Figure 2 Be sure to leave a 1 inch clearance on all sides of the back plate 3 Drill holes and insert appropriate anchors Secure the back plate to the wall with included scr
18. pad with the slots on the back plate Insert the mounting tabs into the mounting slots and press the keypad toward the wall gang box 2 Tighten the two bottom screws Setting Touchpad Unit Numbers SS Note In multiple partition systems all new touchpads default to partition 1 To change partition assignment please see specific panel nstallation Instructions All partitions must be disarmed before entering program mode Panels automatically assign or learn the unit numbers of each bus device upon power up or entering programming mode SuperBus 2000 panels Advent panels and Concord panels with software version 2 0 or newer automatically assign different unit numbers to each SuperBus 2000 mod ule SuperBus panels UltraGard panels and Concord panels with software versions 1 0 1 6 do not automatically assign different unit numbers to each SuperBus 2000 module For these panels alphanumeric touchpads default to 001 If desired or necessary the unit number must be manually changed Guidelines for Assigning Alphanumeric Touchpad Unit Numbers Concord panels with software versions 1 0 1 6 and UltraGard panels Use the following guidelines to avoid communication con flicts between bus devices and the panel Q Always start with one touchpad connected to the panel and make sure it is working properly before connecting additional touchpads Q Whenever possible such as in new installations assign alphanumeric touchpad unit num
19. tically added learned into panel memory when DEVICES ADDED is displayed 7 Press once to exit program mode 8 New alphanumeric touchpads should display Security is Off while existing touchpads will display custom or programmed text Note If the touchpad does not display anything or displays Touchpad Not Enrolled see Troubleshooting Deleting Touchpads Unit Numbers from Panel Memory SS Please see the specific Installation Instructions for informa tion on deleting touchpads unit numbers Adjusting Contrast and Backlighting Please see the specific panel Installation Instructions or User s Manual for more information Testing zz CAUTION Contact the central monitoring station before activating alarms to avoid dispatching local police and fire departments Test the touchpad by arming and disarming the system acti vating the touchpad panics bypassing sensors and by turn ing lights on and off to verify the correct operation Refer to the panel Owner s Manual for system operating instruc tions Panel Programming RSS An alphanumeric touchpad must be used to program some panels For a complete description of programming com mands refer to the specific panel Installation Instructions SuperBus 2000 2 x 20 LCD Alphanumeric Touchpad Troubleshooting cc Troubleshooting SS 8 S Table 4 Concord and Concord Express Troubleshooting Problem Action Solution Tables 3 4 and
20. uchpad 12 Put the new touchpad into the manual configuration mode by pressing and holding the touchpad D and buttons until the display shows DA 001 unit number 001 13 Press BYPASS and the display shows ENTER _ 14 Enter a unit number different from that of the existing touchpads and any other bus devices in the system by pressing any of the touchpad buttons numbered 0 through 7 15 Press BYPASS then STATUS to lock in and display the new unit number for the touchpad 16 Disconnect this touchpad and repeat steps 11 through 16 for any other new alphanumeric touchpads Be sure to disconnect each touchpad after assigning its unit number 17 After assigning unit numbers to all the new touchpads connect each touchpad to its respective wiring harness 18 Set the RUN PROGRAM switch to RUN All touch pads should display 1 OFF SuperBus 2000 2 x 20 LCD Alphanumeric Touchpad Power Up and Bus Communication EEE 19 Set the RUN PROGRAM switch to PROGRAM so the panel can learn all bus device unit numbers All touch pads should display PROGRAM MODE 20 Set the RUN PROGRAM switch to RUN 21 At each touchpad verify correct operation by pressing STATUS The display should show the current system status Powering up Concord Panels with Software Version 2 0 or Newer and Concord Express Panels 1 Verify that all wiring between the panel and touchpad is correct 2 Connect the panel battery and plug in the panel