Home

Samsø User manual

image

Contents

1. Cost of transportation in connection with warranty repairs Assembling reassembling in connection with warranty repairs Compensation for following damages including damage on other objects Warranty conditions These instructions for use are also your proff of warranty The war ranty will not take effect until vendor s stamp information about mo del registration numer and date of purchase invoice if possible have been applid below In case of claims please bring this proof of war ranty to your local vendor Model Vendor s stamp and signature Reg no Date of purchase Q VARDE OVNE Q VARDE OVNE Kongevej 246 6510 Gram Danmark Tel 45 7482 0003 vardeovne dk 19
2. On Ashpan Open Optzndingsluft X Ashpan Closed This option is only for use i fat lightning up As soon as the fire has a good grip rembermber to close again Combustion Air Throttel X Push the Throttel towards right for opening Com bustion Secondary air Pre heated air for the combustion process the amount of wihich can be altered accor ding to the desired room temperature and the effectiveress of the chimney A high level of chimney draughr requires a lesser intake of combustion air MSN Combustion Air Throttel S Push the Throttel towards I left for closing Tertiary air e e a e e ob an Is constantly added air which makes the J Stove brun even cleaner and lowers the i j i content of tar lt the combustion process to an absolute minimum At opti combustion settings glass and com Max height of firewood bustion chamber will be burnt completely clean and the remaining amount of ashes will be minimal Overheating Occors if too much wood is placed in the stove or if the combustion receives too much air How it works Combustion Air Throttel Push the Throttel towards right for opening The grate Ignition air On Ashpan Open Ignition air On Ashpan Closed How to light and stoke fire The first time you light up the stove the enamel wi
3. The first time you light up the stove the ena mel will temper and give off some smoke and a slight smell We recommend that you leave doors and windows open as airing the room will make the smell disappear This tempering softens the enamel making it susceptible to damage Therefore exercise caution and avoid touching the enamel Likewise we recommend opening the door to the stove at regular inter vals for the first hours to prevent the insulati ons rope from sticking to the enamel What to burn This Varde Stove is tested and approved for the burning of wood Only dry wood with a moisture content of maximum 21 percent and the size to fit into the combustion chamber should be used The burning of moist wood will result in an increased amount of tarry soot pollution and uneconomic fuel consump tion Newly chopped wood contains about 60 70 percent moisture which makes it comple tely unsuitable as fuel Allow newly chooped firewood to dry in a open shed for a couple of years before using it in the stove Do not use Consider the environment Also never use toxic materials such as chipboard painted or impregnated wood The use of larger quantities of fuel than re commended in the tabel belove will overtax the stove and resulte in increased temperatu res in the chimney as well as a lowered effici ency This may cause damage to both chim ney and stove and the annulment of the war ranty Topdown Lightning of the fire P
4. confirmaty MANUFACTURER Name Varde Ovne A S Adress Kongevej 246 DK 6510 Gram Danmark Stove Inspection Name RWE Power AG Adress Durner strasse 92 50226 Frechen Germany Notified body number Product Product type Type code Standard Application Fuel Special conditions CE Markning Issued Nominal Output Fuel type Fluegas temperature Efficiency Co release XXXX Varde Sams Sams Heating stove suitable for intermittent combustion Costruction products 89 106 EC standard used EN 13240 Residential Heating Wood Non 2012 5 KW Wood 340 75 0 10 Flooring If the floor on which the stove is to be placed is inflammable the floor must be covered with non flammable material such as steel or glass plate floor tiles or artifical slate covering an area of at least 15 cm from the sides of the stove and at least 30 cm from the front of it Regarding the front however we recommend 50 cm Also the Floor construction must be capable of carrying the combined weight of stove and chimney Weight Steel Varde Sams 80 kg Installation distance If walls are non inflammable the stove can be placed closer to them However we recommend a minimum distance of 5 10 cm to allow for cleaning behind the stove The cleanout gate must be accessible Optimal combustion can only be obtained if fresh air is constantly admitted It is important therefore to ensure that this is the case The best way
5. the smoke is emitted inside your home rather than outside it The smoke plate is moveable and placed on top of the Vermic ulite fire brick side plate You should make sure that it is pushed all the way back against the back wall of the combustion chamber Draught conditions Consult your local stove dealer about how best to adjust the draught in your chimney Hight of chimney If in doubt contact your local stove dealer He will be able to inform you of the correct hight Connection of Flue pipe The Stove is mounted with Flue adaptor on the top Information about the new cast iron adapter Part no 134 Your stove is equipped with the new cast iron adapter from Varde Ovne The adapter is suitable for smoke pipes with inner diameter on 150 mm If you need it it s now possible for you to make a condensate drain hole in the adapter 4 Carefully punch a chisel or the like through the adapter in the outer groove at the arrow mark This way you can establish a condensate drain hole in the adapter Arrow mark for the hole Carefully punch a hole with a Now the condensate hole is chisel or the like ready Continual fresh air A continual supply of fresh air is required in the room in wich the stove is situated This can be achieved by installing 1 2 vents whilst also ensur ring that these can not be blocked The quantity of air used for burning is approx 14 m h
6. to provide a steady flow of fresh air is by installing 1 2 air vent s in the room where the stove is situated One in each side of the room According to existing regulations stoves must be placed with the following minimum distances in mm to inflammable walls and materials The distance from the outer edge of the flue pipe to inflammable material is descriped as for horizontal Flue 300mm and the distance for vertical flue is 225mm Installation distance The stove must in accordance with applicable rules comply with the following minimum distances from inflammable walls and materi als Varde Sams Sides 30 cm Rear 20 cm Distance to furniture 80 cm The chimney Always use a chimney with a diameter of at least 15 cm This corresponds to a clear of 175 cm Make sure the chimney is of a sufficient height that it draws well and that smoke does not both er your neighbours We recommend that you fit your chimney with a damper allowing for draft control This may prove particularly important on windy days Note the damper must never shut off draught completely always allow at least 20 cm free passage through the chimney With nominal usage the stove has tested a flue gas flow of 5 5 g second and with a flue gas temperature of 340 C in a room of 20 C Varde stoves are always fitted with a smoke plate which redirects smoke to make its way to the chimney as effectively as possible This ensures that the heat from
7. Varde Sams Installation and User guide Revsion 01 Q VARDE OVNE Congratulation on purchasing your new stove Varde Ovne A S is a Danish company specializing in functional environmentally friendly and designed quality stoves Index Welcome and index Page 2 Technical specifications Sams Page 3 Regulations and approval Page 4 Flooring and distance Page 5 Chimney Page 6 Air supply Page 7 Operation Page 8 How to light and stoke a fire Page 9 Index Page 10 Vermiculite Page 11 How to choose the wood Page 12 Maintenance Page 13 Troubleshooting Page 14 Spare Parts Page 15 Testcertificate RWE Page 16 Test certificate Teknologisk Institut Page 17 Warranty Page 18 Q VARDE OVNE Technical Specification Sams Model Sams Hight mm 1000 Wide mm 487 Depth mm 349 Weight kg 80 Effect 3 7 kW Nominal Output 5 kW Heated area 30 105m2 Efficiency 75 Flue gas data 5 5 g sek 340 C ved 20 C 11 pa Combustion chamber H x W x D 260 380x200 300x300mm Flue outlet 15 cm Mounting hight top 99cm Distance to non inflammable 5 10cm recommended Distance to inflammable wall and materials Rear 20cm Sides 30cm In front 80cm Important Before lighting up your Varde Stove for the first time we recommend that you read these Regulations All local regulations as well as National and European should be adhered to when instal instructions carefully and contact your l
8. augh in the chimney Inspect the smoke pipe or the chimney for blockage e Clean the inside of the stove removing soot from the upper vermiculite smoke Deflector plate e Make sure the hight of the chimney is correct The glass or the chimney soot up e The wood is too moist Not enough secondary air is applied to the combustion process e You may have shut off the supply of ignition air too aerly when lightning up the stove There always have to be clear flames in the combustion chamber The heat is emitted from the stove e The wood is too moist all energy goes into drying it or of a poor quality e Inspect the position of the smoke plate and make sure there is free passage for the smoke e The amount of combustion secondary air air is not enough Combustion is too intense e Gaskets in the door or the ash pan are no longer tight and need replacement e The chimney draugh is too strong apply a valve in the chimney Inspect that the ignition air is closed The Shake grate is stuck e Inspect the grate for jammed wood nails or the like e Make sure the lever is placed correctly Recycling ee ae Ceramic glass tobe deposited at the local recycling center and sorted together with pottery and porcelain Packing The packing is 100 recycleable Vermiculite Vermiculite plates from the stove must be returned to the local recycling center 14 Spare Parts If Spare parts at any time should b
9. d ID nr 1235 us den 19 juni 2013 Skorstensfejerpategning Morten Gottlieb Jespersen Civilingeniar baggrund af ovenn vnte partikelemission attesteres det hermed at fyringsanlaegget opfylder emissionskravene i bilag 1 til Bekendtg relse nr 1432 af 11 12 2007 vedr regulering af luftforurening fra br ndeovne og braendekedler samt visse andre faste anl g til energiproduktion YAOrganization C068 Biomasse og Bioraffinering ELAB DnttiAttestenBrovniAlle udstedte Attester V arde 1713 Type Fuego 2 rev 1 doc 19 05 2013 T8 XX CES Dete FOF dokument er kun gyldigt hvis det er digttait signeret med OCES digitalsignaturen Tor Morten Gottlieb Jespersen Teknalogisk Institut This POF document is only vald E signed wih fe OCES digis signature for Marten Gottien Jespersen Danish Technological iinstmuie Warranty All Varde stoves go through a close quality inspection and we take pride in always delivering products of a consistent quality This being so manufacturing faults may still occur and on these we offer a 5 year warranty The warranty does not include wearing parts such as the Vermiculite plates in the combustions chamber the smoke plate glass gaskets cast iron bottom and shacking grate Damages whichs occur as a consequence of misuse such as over heating incorrect installation missing or wrong maintenance etc see instructions earlier Damages caused by external influence of a physical character
10. e Ovne A S Vermiculit set Item no 1702505 Deflector plate Left side plade Right side plade Rear cover l 1 1 1 1 How too replace the Vermiculite 1 Deflector lift easily bottom bag end are tilted forward take down 2 The left side plate can be easily liftes up and rotated out 3 Right side plate can be easily lifted up and rotated out 4 The Rear cover is liftes up and out of the stove Mounting of new Vermiculite plates follow point 4 towards point 1 11 What kind of wood to use Generally beech wood is considered the best type of wood for burning It burns evenly without producing much smoke and ashes are clean and take up little space Ash birch and maple wood are fine alternatives How big the firewood Split firewood with a diameter larger than 10 cm Use firewood with a length on 20 25 cm The use of larger quantities of fuel than recom mended in the tabel belove will overtax the stove and resulte in increased temperatures in the chimney as well as a lowered efficiency This may cause damage to both chimney and stove and the annulment of the warranty Also never use toxic materials such as chipboard painted or impregnated wood Lightnings sticks Length 20 25 cm Wide 3x3 cm Normal amounth 10 15 sticks approx 1 kg Firewood Length 25 30 cm Diameter max 10 cm Normal amounth 3 4 firwood approx 2 kg The new stove
11. e ii LRV 11 Emissionen Bezugssauerstoffgehalt Brennstoffe Staubgehalt CO Gehalt 1500 mgiNm 2 RWE D rener Strafe 97 50226 Frechen 1 0221 480 207 4 Arije ds Frechen 01 08 2013 Dipl dg DE Unterschritt rufsttllendeit rs VORWEG GEHEN 16 lacan Sl DANAK TEKNOLOGISK ums INSTITUT TEST Reg nr 300 Teknaingiparten Kongsvang Al 25 TEKNOLOGISK INSTITUT Prone 72 20 1000 Akkrediteret pr vningsorgan DANAK akkreditering nr 300 re bg Uddrag af rapport nr 300 ELAB 1713 NS Emne Br ndeovn Type Varde Fuego 2 Varde Fuego 1 Varde Fuego 1 med 3 delt stalsider Varde Fuego 1 med fedtsten og Varde Sams Rekvirent Varde Ovne A S Kongevej 246 Tiset 6510 Gram DK Procedure ali Pravning efter DS EN13240 A2 2004 Pr vning efter N53058 1 NS 3058 2 og N53059 partikelm lng St vm ling efter DIN plus Zertifizierungsprogramm PROVNINGSRESULTATER Partikelmaling iht NS 3058 og eller stevmaling iht metode DIN plus Partikelemission efter NS 3058 2 25 g kg terstof middelv rdi maks 10 Partikelemission efter NS 3058 2 53 g kg t rstof maksimalt maks 20 St vemission efter metode DIN plus mg Nm ved 13 O maks 75 Bem rk venligst at de oplyste v rdler er et uddrag af prevningsrapponen For yderligere oplysninger henvises til pramingsrapporten se nummer overfor Teknologisk Institut er notificeret pr vningsorgan me
12. e needed please chech the list below Vermiculit Set Artikel nr 2223506 Sealings Door Artikel nr 10014 10008 Glass Artikel nr 1107501 Door Handle Artikel nr 1107124 Door Artikel nr 1107526 Door Gray Artikel nr 1107526G Glass spring with screws Artikel nr 10024 Wood catch Artikel nr 85 15 RWE m F RR Feuerst ttenprifstelle D rener Strasse 92 50226 Frechen Anerkannte Pr fstelle nach dem Bauproduktengesetz notified body number 1427 Anerkannte Pr fstelle nach den Landesbauordnungen Kennziffer NRW 16 Anerkannte Pr fstelle im bauaufsichtlichen Zulassungsverfahren Anerkannte DIN CERTCO Pr fstelle Emissionsmessung Nr 2219 EN Hersteller Varde Ovne A S Kongevej 246 Tiset DK 6510 Gram Auftraggeber Hersteller Typ Sams Bezeichnung Raumbeizer Zeitbrandfeuerstatte DIN EN 13240 Nennwanmeleistung a KW Folgende Emissionsgrenzwerte und Wirkungsgrade wurden bei Nennwarmeleistung unter den Pr fbedingungen der DIN EN 13240 mit den angegebenen Brennstoffen f r o g Feuerstatten eingehalten Zuk nftige Anforderungen f r sisi 1 2 Stufe Emissionen Grenzwert j Brennstoffe Staubgehalt 40 1250 mg Nm EN Scheitholz Green ugssauerstoff Brennstoffe gehalt 40 CO Gehalt eee NOx Gehalt 200 sai ug jehalt Staubgehalt CO Gehalt E 13 Scheitholz NOx Gehalt Derzeitige Anforderungen fiir di
13. ereafter the combustion air are ajusted to the need of heat Be aware not to close to much for the air supply otherwise the fire will die the fire must alway be bright and clear In most instances however you will have to achieve the best combustion air settings your self as the height and draught of your chimney as well as the quality of the firewood are deci sive factors in determining how your particular stove is best set If the furnace nominal heat output is too large compared to the heat demand you can reduce the output as descriped here Stoke a small amount of wood than usual for example 1 2 to 1 3 kg and preferably consist end of 3 4 smaller pieces of wood Apply full air to ignite the wood properly then you can reduce the combustion air perhaps down to approx 60 Be aware not to close to much for the air supply otherwise the fire will die the fire must alway be bright and clear With this method it depending on the chimney wood quality etc is possible to reduce the stove heat output from a nominal 5 kW down to maybe 3 to 3 5 kW Please be aware that it can lead to poor combustion if you regulate too much down the com bustion air resulting in a lower efficiency and increased emission levels in the smoke increasing pollution Tertiary air If you are wondering why your stove is fitted with an gap in the rear vermiculite plate in the combustion chamber with small holes through the back steel plate where air
14. is running through into the combustion chamber This is merely a consequence of our newly developed combustion system We refer to these air ducts as the tertiary air and will prove helpful as you install your new Varde stove When refilling the stove with wood we recommend opening the stove door only once embers are left in the combustion chamber Opening the door whilst the flames are still burning and producing smoke and gas might cause smoke to slip into the room instead of up the chimney Should you have some issuses with the lightning or the function see section on troubleshoo ting Operation ONO Grate Wood catch Vermiculit plates Ash tray Cast iron Door Steel Top Throttel for Ignition Air Combustion Air Throttel Storage 10 Vermiculite The plates in the Combustion Chamber are Vermiculite plates and will aventually be worn as will the smoke plate Should you accidentally breah the plate for instance by hitting it hard with a piece of wood this does not effect the quality of the combustion You need not re place the plate until the gap is 5 mm wide Vermiculite A special non flammable material The vermiculite fire plates both isolate and protect the stove from attrition Vermiculite plates and deflector not covered by the warranty Vermiculite is a very porous material therefore handle with care When refilling the stove put the wood careful ly use the glove Only use original parts from Vard
15. lease do not load more than shown on page 7 The following optimal register and fuel quanitty settings are recommended in case of similar chimney draught Fuel Quanti Primary Air Combustion Nominal Chimney Efficiency Refill interval at ty open Air open Output Draught nominal output kg 90 90 kW PA gt i 90 minuts ca 80 almost open 1 2 0 closed 5 0 12 75 ca 45 12 Maintenance Like any piece of equipment in daily use your stove needs maintenance The stove should only be cleaned when cold Use a dry cloth for cleaning the exterior of the stove Clean the interior regularly by removing ashes soot and tar from the combustion chamber The smoke deflector plate should be removed for cleaning as the reverse side will be covered in dirt and soot Finally check that the smoke pathway through the flue pipe and chimney is completely clear You should also inspect the rope seals in the door and ash pan for signs of wear Replace them if they no longer seal properly Also remember to lubricate the door hinges as required Glass pane The glass pane should be cleaned using Varde Glas Cleaner which is available at all DIY centres selling Varde Ovne stoves Empty the Ash pan regularly It can be emptied into your dustbin as long as you make sure it does not contain any hot embers If in doubt about how to clean your stove contact the dealer where you bought your stove or your chimney sweeper It is e
16. ll temper and give off some smoke and a slight smell We recommend that you leave doors and windows open as airing the room will make the smell disappear This tempering softens the enamel making it susceptible to damage Therefore exeercise caution and avoid touching the enamel Likewise we recommend opening the door to the stove at regular intervals for the first hours to prevent the insulations rope from sticking to the enamel Never use highly inflammable fluids such as methylated sprit and petrol for lighting up We recommend a Top Down lightning where you light the wood in the upper area of the com bustions chamber and not in the ground This method is the most environmental metod to light a fire The metod will keep the glass clean In the combustion chamber you make a cross of 4 small pieces of wood with a small distance between each one of them On top you of them you make another cross of 8 12 smaller sticks 0 5 1 kg on top of this firewood and in bet ween use 2 3 kildning blocks A thin layer of ashes at the bottom of the stove makes lighting up a fire easier Before lighting up the stove Ignition Air on the ash pan for access of primary air The Throttle for the Combustion Air is drawn towards the right and hereby fully openes for combustion air When the fire burns remember to close the the Ignition air and shaking grate again when the stove and chimney might become overheated and will invalidate the warranty H
17. ocal stove ling your stove vendor or building authoorities to inquire about existing regulations regarding the intallation of stoves Please follow these regulations closely All Varde Ovne stoves are closed fireplaces The stove is designed for intermittent com bustion and can be connected to a chimney used by other fireplaces as long as the app ropriate rules and regulations are adhered to Inspection of installation It is very important that the installation is in spected by a qualified chimney sweeper before the stove is used the first time This Varde Stove Has passed the Danish European Standard DS EN 13240 Norwegian NS and the German Stufe 2 test and have thereby proved to be a environmentally friendly product Proffesional installation We recommend that you consult with the dealer where you purchased the stove or an other competent installer as there may be specific things to consider during the installa tion You should also reseive the applicable rules for installing the stove and follow them Please Note You are by law required to register your stove at the local chimney sweeper Until installation keep the stove dry and not to cold The stove cannot stand moisture That an existing chimney not necessarily is effective enough for a new modern stove Vermiculite is a very porous material therefore handle with care When refilling the stove put the wood careful ly use the glove EC declaration of
18. specially important to check the stove and the chimney for blockages after a long period of non use The enamelled surface of the stove may wear down in certain places if the stove is overheat ed Worn surfaces can however be repaired with a special Senotherm spray paint available from your local dealer The plates in the combustion chamber are vermiculite plates and will eventually become worn as will the smoke deflector plate Accidental breakage of a plate for instance by hitting it hard with a piece of wood will not affect the quality of the combustion You do not need to re place the plate until the gap is 5 mm wide Only use original parts from Varde Ovne A S The door is equipped with a spring which pulls the gate closed This is a legal requirement in many countries The spring is fitted to the hinged side of the door but can be removed if you prefer the door not to be spring loaded Do not make any unauthorised changes to the stove All external parts of the stove become hot during use and you should therefore exer cise due caution IMPORTANT Chimney fires Should your chimney catch fire cut off the air supply to the stove s combustion chamber and contact the emergency service The majority of fires die out after the oxygen supply is cut off You should subsequently contact your chimney sweeper who will check your stove and chimney for damage 13 Troubleshooting Smoke enters the room e Not enough dr