1. Under countdown mode long press button SET 3 seconds to open backlight long press it 6 seconds to enter countdown setting mode Please refer figure 4 Press button MODE to switch setting items Press button SET to set digit Long press SET to save setting and exit to countdown mode co 5 Figure 4 2 5 Altimeter mode lt a yh Under time mode press MODE two times S to enter altitude mode E Sea level LCD display weather forecast cda g bu alte temperature sea level altitude m Bie climb altitude Please refer figure 5 Climb altitude Long press MODE to clear climb altitude to zero and start to measure Sea level altitude setting The altimeter is measured base on air pressure which changes at any time Altimeter will take this change as a vertical movement Normally there will be around 20 m changes per day So it s neccessary to calibrate the altitude after we know accuracy sea level altitude Under altitude mode long press SET 6 seconds to enter sea level altitude calibration ae please refer figure 6 Press MODE to switch digit press SET setting number Long press SET to save setting and exit to altimeter mode 6 m ee a 24 18 12 9 6 3 OH Figure 6 8 2 6 3days history record mode Under countdown timer mode press MODE three seconds to enter 3days history record mode HISTORY will display on screen LCD display weather forecast hi
2. MODE gt 1 2H 24H press MODE gt hour press MODE minute press MODE month press MODE gt date press MODE gt pressure unit hpa inHg press MODE altitude unit m ft press MODE Suitable fishing pressure thousand hundred ten one Long press SET Saving and exit to default mode time mode 2 3 Suitable fishing pressure setting The default suitable fishing pressure of this unit is 1002hpa When current air pressure is higher than it fishing icon es will display on screen Different region different sea level altitude the fishing pressure will be different also Please set suitable fishing pressure base on your local altitude Detail setting method please refer item 2 2 Sheet of fishing pressure for different altitude Only for reference Altitude M id aa Altitude M ke eas Altitude M fake A esas 10 9 1500 sso 220 7 400 90 500 sso 2500 mi 50 98 1600 sig 2600 69 o E 2687 e oe E 5 ne E 687 90 9 200 ST 300 652 2 4 Countdown timer mode Under time mode press button MODE to enter countdown timer mode LCD display weather forecast temperature countdown timer suitable fishing icon Please refer figure 3 Turn on off countdown press SET button to turn on off countdown When times up it will remind by sound in 30 seconds Figure 3 Countdown timer setting
3. Digital Fishing Barometer User Manual Digital Fishing barometer Thank you for your purchase of Sunroad SR204 Digital Fishing Barometer Design Strategy It has been known that barometric pressure is one of the most important factor to influence fishing When barometric pressure is higher DO in the water will be higher Fish will be active and has a good appetite On the contrary fish will be dispirited and has a bad appetite If we know the trend of barometric pressure it can greatly increase the chance of successful fishing Functions Smart tracking barometric pressure for 6 fishing places Smart remind suitable fishing time 24 hours barometric pressure trend chart Adopt super accuracy barometric sensor from Swiss 3 days air pressure amp temperature record Incorporates altimeter barometer temperature weather forecast countdown timer time amp date functions etc IPX 4 waterproof Specifications Barometer Range from 300hpa to 1100hpa Hpa and Inhg unit switch available Resolution of 0 1hpa Thermometer Range from 10 C to 60 C C and F unit switch available Resolution of 0 1 degree Datarecords 6 sets data for fishing places including pressure time water depth countdown timer Range from 0 to 59 59 59 Weather forecast 4 weather status indicating sunny partly cloudy cloudy rainy The weather forecast for next 12 to 24 hours Time 12h and 24h format sw
4. ethod under time mode long press MODE to collect current air pressure air pressure will flash on screen press SET to enter fishing place mode Press MODE to select fishing place code Press SET to save and exit Long press MODE then press SET ml el BARO f TiTi ar TEE Hii ae m ae a hpa Press SET Press MODE to select to save and exit code of fishing place 11 2 7 2 Pressure tracking for fishing place Step 1 Link fishing place At fishing place recording the initial air pressure base on method of item 2 6 1 When coming back usual staying place Such as home or company please long press MODE to link fishing place under time mode Step 2 Checking current air pressure of fishing place when we are staying at usual place such as home or company steps are as below 1 Under time mode press SET two times to enter pressure tracking mode 2 Press MODE to switch fishing place code Bool 2 90 frist ishing ce saro d 4 17 im rm HILS Press SET Current pressure for 1st fishing place Initial pressure mode Pressure tracking mode 12 2 8 Low Battery Indicator Unit will be alarm every 5 seconds when battery is low power Remark Please change battery when low power supply Otherwise it can not measure pressure accuracy or bring other problems 2 9 How to know fishing time is coming 1 Checking fish icon whether display on screen or not If fishing icon is disp
5. ghest lowest temperature date highest lowest air pressure pressure trend chart Please refer figure 7 Press MODE to browse three days record in turn Press SET to browse the highest lowest temperature and highest lowest air pressure for each day PS 3days history record is applying in very cold weather condition such as winter or autumn if temperature difference in 3 days is changing smaller and smaller or if the lowest temperature in 3 days is becoming higher and higher it should be fit for fishing in future few days Under 3days history record mode there is maximum and minimum temperature for each day It can help us to know whether it fit for fishing or not 3 History date j History air pressure Figure 7 2 7 Pressure of fishing places Under time mode press SET to enter pressure of fishing places mode LCD display fishing water depth time initial record air pressure fishing place code fishing icon Please refer figure 6 Press MODE to switch among different fishing places code Cast water depth F a 1256 water Record time Initial record air pressure Figure 8 10 2 7 1 Record initial air pressure for fishing place Before tracking air pressure for fishing places at first time when arriving the fishing place such as one lake one river etc we should record an initial air pressure There are two methods to record initial air pressure as below 1 M
6. itch available Date Month day format or day month can interchangeable Three days history data record Record three days maximum minimum pressure maximum minimum temperature provide the basis for fishing Low battery alert Voice remind every 5 minutes when battery is low power Battery life about 12 months Spare parts manual 1 Carabiner 1pcs Battery 1pcs 2 1 Start Installing the Battery Rotate the back cover counter clockwise gripping the unit with both hands using your index fingers and thumbs Rotate until it stops then gently pry off the back cover with your fingers exposing the battery compartment Note you may have to squeeze on the outer ring not the display and apply force in the clockwise and counterclockwise direction repeatedly work back and forth to free the back cover after extended use due to sweat and other debris Make sure your fingers are dry Insert the CR2032 battery side up and close the back cover insuring the gasket is firmly seated in the housing trace as shown in Figure 1 Battery To remove the battery use a small pen or paperclip to pry the battery out of the battery compartment To close the back cover rotate the back cover clockwise until the back cover is completely closed The display should be powered up in the time and date mode and ready for use Gasket Figure 1 2 Operating instructions 2 1 Default mode time mode LCD display weathe
7. layed on screen it fits for fishing 2 Normally pressure range from 1002 hpa 29 58inHg to 1005 4hpa 29 67inHg it is suitable for fishing Range from 1006hpa 29 70inHg to 1028hpa 30 35inHg itis perfect for fishing For other pressure itis not suitable for fishing 3 Checking pressure trend arrow if the arrow is increasing it will be great time for fishing 4 During Winter or Autumn if temperature difference in 3 days is changing smaller and smaller or if the lowest temperature in 3 days is becoming higher and higher it should be fit for fishing in future few days Attentions 1 This unit is not designed for professional or special purpose 2 The unit is water proof but not for diving Don t submerse in water 3 Do not operate outside of the specific temperature range 10 to 60 C 13
8. r forecast temperature time date local air pressure pressure trend arrow pressure trend chart fish icon if pressure is not fit for fishing this icon will not display on screen etc Please refer figure 2 Pressure trend chart shows air pressure change in passed 24hours X axis is time Y axis is air pressure every division means 2hpa Pressure trend arrow forecast pressure change in future 12 hours Maa she if cunonuprossure is higher than fishing val en aaa iit pressure the fishing icon will Theniarieter lt J nc de display on screen If not the f qg 5B fishing icon will disappear l mT Before first using please set up i LI LI h 4 initial data such as time date Barometric ee temperature unit air pressure unit trend arrow altitude unit and sea level altitude etc Detail setting method please anne Barometric trend chart refer item 2 2 Setting mode in past 24 hours Time amp Date Barometer Fishing time remind Figure 2 2 2 Setting mode Under time mode long press SET 5 second to enter setting mode weather icon will be flashed Press MODE to switch setting items Press SET to detail item Long press SET again to save and exit setting mode In setting mode if there is no operation in 30 seconds it will save and exit setting mode automatically Steps Time mode Long press SET 5second weather forecast press MODE gt temperature unit C F 0 press