Home
        Installation & operating manual PDF
         Contents
1.      The chimney is telescopic and is designed for hood installations between 650 to 750mm above the  cooking surface      Ascertain the desired installation height of the canopy hood       Any installation above 750mm will compromise the extraction performance       The air outlet from the motor requires 150mm round ducting which requires 170mm diameter hole    in the ceiling  C    A 650mm electric cook top  min m  A 650mm gas cook top  min  FILTER SURFACE     lt     HOB TOP       Robinhood       Pre Installation   continued       Contents of packaging  Typical equipment required   1 x rangehood electric drill and screwdriver   1 x packet of fasteners tape measure and spirit level   2 x chimney pieces  upper and lower  step ladder   2 X support frames duct tape  if ducting    1 x Installation and Operating Instructions jig saw  if ducting     ladder  if ducting   Ducting Options  The method of ducting should be carefully considered before installing the rangehood  The guide below recommends  the ducting components to use for all common ducting configurations   through the top of the home  for the roof and  soffit  and through the rear of the home  150mm round ducting should be used in conjunction with this model    rangehood     The highlighted area in the table below gives the recommended Uniduct item numbers for different  mounting and outlet options     Duct mounting option    Top  roof  Top  soffit eave                             Uniduct item numbers    150mm      Extra
2.   600mm  This distance shall be at least 650mm  if the rangehood is installed over a gas  hob     If the instructions for the gas hob specify a greater distance  this has to be taken into  account     Attention should be given to ensure that any applicable regulations concerning the  discharge of exhaust air is fulfilled     If the supply cord of this equipment is damaged  it must only be replaced by the  manufacturer or its service agent or a similarly qualified person in order to avoid a hazard     PP Pe PRP PPPEP    o    CAUTION  Accessible parts may become hot when used with cooking appliances    9 6  Robinhood       Warranty Certificate  New Zealand        Terms and Conditions   The following conditions apply in respect of the warranty given in this certificate    1  Parbury Pty Limited     Parbury     warrants the following Robinhood products against manufacturing defects and faulty  materials  under normal use and subject to the exclusions in this certificate  for a period of   Rangehood   24 months from date of original purchase for domestic use   Uniduct     12 months from date of original purchase for domestic use   Ironing centre     12 months from date of original purchase for domestic use   Waste disposal     24 months from date of original purchase for domestic use      Original purchase     when used in this certificate  means purchase by the customer directly from Parbury or one of its  approved suppliers    2  This warranty is limited to the repair or replace
3.  au       Warranty Certificate  Australia        Terms and Conditions   If you are a consumer under the Australian Consumer Law  our goods come with guarantees that cannot be excluded under the Australian  Consumer Law  You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or  damage  You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount  to a major failure    1  Parbury Pty Limited     Parbury     also warrants the following Robinhood products against manufacturing defects and faulty materials  under  normal use and subject to the exclusions in this certificate  for a period of     Rangehood  Ovens  Cooktops   24 months from date of original purchase for domestic use    Uniduct     12 months from date of original purchase for domestic use    Ironing centre     12 months from date of original purchase for domestic use    Taps  including Pull out and Mixer taps     5 years on parts only from date of original purchase domestic for use  24 months parts and labour from  date of original purchase for domestic use   Sinks sets    5 years on stainless steel sink including draining bench from date of original purchase for domestic use  6 months on all stainless steel  accessories  including wire rack  colander and tray from date of original purchase for domestic use     Supertub   5 years on stainless bowl  24 months on Tap  Cab
4.  lengths and or bends may be required  depending on the length required and whether there is any structural  material in the way  e g  rafters     Please note that this chart is designed as a guide  Please consult Robinhood customer services if unsure   For NZ phone 0800 760 667 or www robinhood co nz  For AUS phone 1800 648 556 or www robinhood com au        Robinhood       AUNE    a    For the ducting mark out and cut a  170mm hole in the ceiling     Note that this hole is not central to the four mounting screw holes     6   Te    10     Installation       Before drilling any holes check that the area behind the surface to be drilled is clear of any  electrical cables  pipes etc  Fixing to a solid joist or 50mm deep truss is recommended     Whenever possible protect the hob top with cardboard or similar     Before commencement unpack the canopy hood and check that it functions correctly   Use a plumb line to mark the centre of the cooking surface on the ceiling   Using the upper support frame as a template mark the eight holes on the ceiling   Ensure that the support frame front edge is parallel with the bench top and  that the plumb line mark is central to the mounting screw holes   Drill holes in the ceiling at the points marked   a  When fitting to a 50mm truss drill a pilot hole through  the ceiling and the truss   b  If securing to any other ceiling type please use appropriate  fasteners and follow their instructions of use carefully        Fix the upper support frame 
5.  or other fuels     There is a fire risk if cleaning is not carried out in accordance with the instructions  You must read the details  concerning the method and frequency of cleaning     Do not flamb   under the rangehood     Exhaust air must not be discharged into an existing flue which is used for exhausting fumes from appliances  burning gas or other fuels     The minimum distance between the hob surface and the lowest part of the rangehood is 600mm  This distance  Shall be at least 650mm  if the rangehood is installed over a gas hob  If the instructions for the gas hob specify  a greater distance  this has to be taken into account     Attention should be given to ensure that any applicable regulations concerning the discharge of exhaust air is  fulfilled  If re circulating  ensure that the side outlet grilles on the upper chimney are not obstructed  Evena  partial obstruction will restrict the efficiency of the rangehood     Stainless steel is very easily damaged during installation if abraded or knocked by tools  Protect the rangehood  with the cardboard box or plastic bag during installation     Check the contents of the packaging  check all electrical functions of the canopy before installation   Canopy is heavy  Please ensure adequate care when installing to prevent personal injury     CAUTION  Accessible parts may become hot when used with cooking appliances    9 6  Robinhood       Pre installation          The canopy hood is designed for 2400mm or 2700mm ceilings  
6.  soap  metal pads and strongly alkaline or acidic cleaners   Heat damage  including from washing the product at high temperatures   Impact or mishandling the product  including the impact caused by objects scraped along  thrown or dropped on the product  surface or excessive weight being placed on the product   Structural or support changes in or affecting the building or the application where the product has been installed   Failure to clean or maintain the product as recommended  or  Any other causes specified in the product information as being excluded from this warranty   Variations with the colour or gloss within the product or any ageing or fading of colour  shine or gloss level over time are not  not covered by this warranty  The warranty does not cover visual imperfections or blemishes in the surface and edges of the  product that were not brought to your supplier   s attention at the time you inspected the product   Costs incurred on installation or removal of a product  or any reinstallation of a product  or any associated costs  are not  covered by this warranty   Parbury will not be liable for consequential or indirect loss or damage whatsoever and however arising out of or in connection  with the supply  performance or removal of the product  including  but not limited to  loss of profit  loss of revenue  loss of  contract  loss of goodwill or increased cost of workings  even if due to the negligence of Parbury or any of its approved  suppliers  employees or age
7.  warranty does not apply where  in Parbury   s opinion    The defect is caused by misuse  wear and tear  dirt  fire or accidental damage    The product has been repaired or serviced by an unauthorised person    The product was not installed in accordance with our instructions    The product was purchased overseas or was not designed for use in Australia    The product was not used  cleaned or cared for in accordance with our instructions    The product was used outdoors    2  All Robinhood rangehoods are suitable for indoor use only and not suitable over BBQs or charcoal cookers designed for outdoor use    3  In addition  this warranty does not extend to damage or defects which in our opinion  directly or indirectly arise from or are due to  exposing  the product to acidic or corrosive materials or chemicals such as dyes  solvents  denture cleaner or acetone  using inappropriate household  cleaning products such as abrasive cream or powder cleansers  furniture polish  bleach  mentholated spirits  drain cleaners  sugar soap  metal  pads and strongly alkaline or acidic cleaners  heat damage  including from washing the product at high temperatures    impact or mishandling the product  including the impact caused by objects scraped along  thrown or dropped on the product surface or excessive  weight being placed on the product  structural or support changes in or affecting the building or the application where the product has been  installed  failure to clean or maintain the prod
8. Installation and Operating Instructions    Issue 1    Description  ROBINHOOD ISLAND CANOPY CURVED GLASS 90CM  Model Numbers  RIV3CL9OG       Product may vary slightly from the picture    9 6  Robinhood       Pre installation       Thank you for purchasing a quality Robinhood rangehood  Robinhood has a high standard of quality control and every  rangehood is tested and approved before it leaves the factory           PRP RP BPP PRP PPR PPP o    Important     Please read the entire instructions before installing the rangehood  always switch power off prior to installation   All electrical work must be done by a registered electrician in accordance with local and national electrical codes  as applicable  For your safety  this product must be earthed     The power socket must be accessible and enable the end user to isolate the rangehood from the power for the  purpose of internal cleaning or maintenance     A power outlet should be within 1500mm of the power cord exit from the rangehood    The canopy hood is not intended for use by persons  including children  with reduced physical  sensory or metal  capabilities  or lack of experience and knowledge  unless they have been given supervision or instruction  concerning use of the appliance by a person responsible for their safety    Children should be supervised to ensure that they do not play with the appliance     There shall be adequate ventilation of the room when the rangehood is used at the same time as appliances  burning gas
9. id  assembly of the island canopy hood    Finish assembling the ducting ensuring the path is as short  straight  and smooth as possible    Connect to the power supply and switch on the power to the  canopy hood    Slide the upper chimney piece up to the ceiling and secure in place  with the four screws supplied    Remove the transport tape that holds the oil cup in place under   the motor unit and fit the filters                                 Robinhood       Control Panel    Timer switch    Canopy hood will remain on a low  mid or high speed for 15 minutes to clear away all residual cooking  odours before switching off automatically      0000       h  Lights Speed settings Timer    Cleaning and maintenance       Particular care must be taken with the aluminium filters which must be periodically cleaned  at least every  two months   Remove the grease filters and wash them either by hand using hot soapy water or in the  dishwasher using mild detergent     Note  some discolouration of the frame may occur   Caution  Never use abrasive or oil based liquid cleaners     To clean the stainless steel and glass components of the appliance use mild detergent and warm water  In  areas of high humidity and coastal environments cleaning should be carried out frequently     LED bulb replacement                 1  Switch off the power to the canopy hood and allow the bulb to cool  a   2  Use a small bladed screwdriver to pop out the light assembly  taking care not t     damage the surround
10. inet and other components from the date of original purchase for domestic use      Original purchase     when used in this certificate  means purchase by the customer directly from Parbury or one of its approved suppliers     2  This warranty is limited to the repair or replacement  at our option  within the warranty period of any component part which we at our  discretion determine to contain faulty materials or a manufacturing defect in breach of this warranty  This warranty is subject to terms and  conditions set out in this certificate    3  The warranty only applies within Australia    4  For warranty service outside of capital city metropolitan area or 30 km from nearest authorised service agent you will be liable for reasonable  travelling expenses and the cost of transport of the product or parts to and from the service agent   5  To make a claim under this warranty  you must produce the original invoice or other purchase documentation as proof of the original purchase  date  You must send your claim to Parbury Pty Limited  76 Postle Street  Coopers Plains QLD 4108 within 7 days of any alleged defect or failure of  the product first becoming apparent  you are responsible for the expense of making a claim under this warranty     This warranty is given by   Parbury Pty Ltd  ABN 83 004 568 138    Telephone  1800 648 556   Facsimile  1800 628 577   Email  enquiries robinhood com au  www robinhood com au   Attention Customer Services Manager    Warranty exclusions   1  The
11. ing material    3  Unplug the assembly from the wiring    4  Plug in the new assembly    5  Push the light assembly back into place                Optional accessories     For other accessories  parts and service  please contact your local supplier  Refer to the Warranty  Certificate      9 6  Robinhood       Product approvals and ratings    Product approval number SGSEA 110866  Product rating 223W  220 240 Volt 50 hertz    Electrical approval AS NZS 60335 2 31 2004   A1   A2   A3    EMC AS NZS CISPR14 2001    Important safety information       The canopy hood is not intended for use by persons  including children  with reduced  physical  sensory or metal capabilities  or lack of experience and knowledge  unless they  have been given supervision or instruction concerning use of the appliance by a person  responsible for their safety    Children should be supervised to ensure that they do not play with the appliance     There shall be adequate ventilation of the room when the rangehood is used at the same  time as appliances burning gas or other fuels     You must read the details concerning the method and frequency of cleaning   There is a fire risk if cleaning is not carried out in accordance with the instructions   Do not flamb   under the rangehood     Exhaust air must not be discharged into an existing flue which is used for exhausting  fumes from appliances burning gas or other fuels     The minimum distance between the hob surface and the lowest part of the rangehood is
12. ment  at our option  within the warranty period of any component part  which we at our discretion determines to contain faulty materials or a manufacturing defect in breach of this warranty   This warranty is subject to terms and conditions set out in this certificate    3  The warranty only applies within New Zealand    4  The customer must produce the original invoice or other purchase documentation as proof of the original purchase date     Warranty exclusions   1  The warranty does not apply where  in Parbury   s opinion   The defect is caused by misuse  wear and tear  dirt  fire or accidental damage   The product has been repaired or serviced by an unauthorised person   The product was not installed in accordance with our instructions   The product was purchased overseas or was not designed for use in New Zealand   The product was not used  cleaned or cared for in accordance with our instructions   The product was used outdoors   All Robinhood rangehoods are suitable for indoor use only  and not suitable over BBQs or charcoal cookers designed for  outdoor use   In addition  this warranty does not extend to damage or defects which in our opinion  directly or indirectly arise from or are due to   Exposing the product to acidic or corrosive materials or chemicals such as dyes  solvents  denture cleaner or acetone   Using inappropriate household cleaning products such as abrasive cream or powder cleansers  furniture polish  bleach   mentholated spirits  drain cleaners  sugar
13. nts   Charcoal filters and light bulbs are not covered by this warranty  This warranty and the statements contained in this certificate or other documents given to you do not exclude  restrict or  modify the application of any term implied into this warranty by statute  provided that  to the extent any statutory provision  permits Parbury to limit its liability for a breach of an implied condition or warranty  Parbury   s liability for such breach is limited  to the payment of the cost of replacing the product  repairing the product or acquiring an equivalent product   Subject to clause 5  our obligations under this warranty are limited to those set out in this certificate  and this warranty is  expressly instead of all other warranties  express or implied  including any implied warranty of merchantability or fitness for a  particular purpose and notwithstanding any course of dealing between the parties or custom and usage in trade to the contrary   Should warranty service be required  please contact us     Free Phone  0800 760 667   Free Fax  0800 276 246   Email  enquiries robinhood co nz   Website  www robinhood co nz   Terms and conditions are subject to change without notice    New Zealand Australia  Parbury Ltd Parbury Pty Ltd    Telephone  0800 760 667 ABN 83004568138  Facsimile  0800 276 246 Telephone  1800 648 556    Email  enquiries robinhood co nz Facsimile  1800 628 577 a  www robinhood co nz Email  enquiries robinhood com au Ow  RobD   N hooc    www robinhood com
14. to the ceiling using the screws supplied   Secure ducting to the top of the motor housing  use duct tape if required   Solid ducting  galvanized or plastic is recommended  Use flexi   ducting only in difficult installations and if used ensure that it is pulled tight   2   The smoother  straighter and shorter the ducting the quieter and more z   efficient the canopy hood will perform  Tape the power plug to somewhere  6   near the top of the ducting  this will enable easy access to the plug after  installation    Secure the lower part of the support frame to the top of the canopy hood  using the screws provided    Strip the plastic protective film off the two chimney pieces and place these  over the lower support frame  The lower chimney will rest on top of the  canopy hood and the upper chimney will be extended and secured to the  upper support frame  To ensure that the upper chimney does not slip  inside the lower chimney  secure it so that the upper chimney is showing   Duct tape or two screws nails through the upper chimney securing nola  will do this   10   Offer the canopy hood  lower support frame  chimneys and ducting   up to the upper support frame and secure in place with the four screws  provided  The dimension between the filters and the cooking surface  should be in line with those suggested in the    height of canopy hood    3  section  An additional person will be required for this operation ora  simple support frame manufactured to the correct dimensions will a
15. uct as recommended  or any other causes specified in the product information as being excluded  from this warranty    4  Variations with the colour or gloss within the product or any ageing or fading of colour  shine or gloss level over time are not covered by this  warranty  The warranty does not cover visual imperfections or blemishes in the surface and edges of the product that were not brought to your  supplier   s attention at the time you inspected the product    5  We will not be responsible under this warranty for  nor pay the costs of  removing the existing product  or reinstalling the new product  or any  associated costs or damages    6  Charcoal filters and light bulbs are not covered by this warranty   The benefits given by this warranty are in addition to other rights and remedies of consumers under any law in relation to the goods which  cannot be excluded     This warranty certificate is not intended to create a contract between Parbury Pty Limited and the purchaser     New Zealand Australia  Parbury Ltd Parbury Pty Ltd    Telephone  0800 760 667 ABN 83004568138  Facsimile  0800 276 246 Telephone  1800 648 556    Email  enquiries robinhood co nz Facsimile  1800 628 577     www robinhood co nz Email  enquiries robinhood com au Ow  RobD   N hooc    www robinhood com au       
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
  Fiche technique cire parquet - 27 juin 2007  Acer Aspire R3600 Owner's Manual  Kompernass PLP 180 Brochure  1756-PM001C-EN-P, Logix5000 Controllers Common Procedures  Users Guide - Educational Service Unit #3      LanEdge OmniConnect ISDN User Guide  Climatiseur Gainable DC Inverter Notice d`installation    Copyright © All rights reserved. 
   Failed to retrieve file