Data Capture Module™ OnBoard Weighing Data Capture Operator`s
Contents
1. in Canada or elsewhere in United States Western Canada NORAC SERVICE CENTER NORAC SYSTEMS INT INC 400 42nd Street SE 803 46th Street East Minot ND 58701 Saskatoon SK S7K 0X1 USA CANADA Eastern Canada NORAC SYSTEMS INT INC 62 Plant Farm Blvd Brantford ON N3T5T9 CANADA Freight will be paid one way and returned by the same carrier unless instructed differently NORAC or its authorized Service Center will repair or replace at its option any defective part or component at no cost to the purchaser during the Warranty period If service in the field is required NORAC will authorize on site repairs at no charge for parts and labour Travel time travel and per diem expenses to and from the place where repairs are made will be charged to the purchaser at prevailing rates Any evidence of negligent or abnormal use defacing or alteration of serial numbers or repairs attempted by other than NORAC authorized personnel using NORAC certified or recommended parts automatically voids the warranty NORAC will not warranty any complaints relating to inadequate installation unless the installation was performed by NORAC adjustments or calibration The forgoing states the entire liability of NORAC Regarding the purchase and use of its equipment NORAC will not be held responsible for any consequential loss or damage of any kind This warranty is in lieu of all other warranties except as set forth above Any implied war
2. Check the connection of the in line cable with the original printer socket If all the connections are secure but the unit still does not function contact your NORAC Service representative for further assistance NOT PRINTING TRANSACTIONS 2 0 If the normal transactions are not printing but the Data Capture Module s LED is flashing ensure that the paper ticket is inserted all the way in under the print head Check the cable from the printer for proper connection Check whether normal transaction printing is working after the Data Capture Module is disconnected from the header If it prints then contact your NORAC Service representative for further assistance If still no printing occurs for normal transactions remove the header cable connection and restore the printer connection directly to the original connection If it prints then contact your NORAC Service representative for further assistance 10 6 0 NORAC SYSTEMS INTERNATIONAL INC STATEMENT OF LIMITED WARRANTY NORAC SYSTEMS INTERNATIONAL INC also known as NORAC warrants all control systems equipment of its manufacture to be free of defects in material and workmanship for a period of two years This warranty period is for a period of 24 months from the date the equipment is delivered by NORAC or its authorized dealer to the purchaser NORAC will repair free of charge items returned within the warranty period to one of the following authorized warranty locations
3. 30 Operati Naena A T EA ESEA 6 EED renee T i ER ir ee E a ENA 6 Printere a a a a a 6 R setisnteno iene a d aa o loos 7 JACK e austen a teat autvavtusettadnee meee niasecs Marites tale T In order to upload the stored information to a PC the removable module must be removed from the header Power must be supplied to the module through the jack A 110Vac to 9Vdc adapter is provided with the option kit 7 1 0 Introduction Features The Data Capture Module is an accessory for NORAC s OnBoard Weighing System It will electronically record up to 500 transactions on your OnBoard scale By recording scale transactions electronically you can ensure that all product is accounted for and invoiced properly Further by reviewing the transaction times dates and product flow rates you can also assess the productivity and efficiency of your equipment and people A summary of the transaction records stored in the Data Capture Module can be printed directly on the ticket printer in the OnBoard control box These reports detail the amount of product loaded and unloaded for each day the unit is used Further the Data Capture Module can be easily removed from the OnBoard control box and connected to a personal computer PC Then these detailed transaction records can be uploaded to the PC for further processing and reporting In order to upload the records to a PC you need NORAC s PC Upload Option see Section 4 0 Package The basic pa
4. the edge connector is plugged in firmly Turn on the main control panel power switch and check that the LED is ON Reset Button Access Status LED Print Button Power Jack Edge Connector Figure 4 Data Capture Module 3 0 Operation LED The removable module receives power through the edge connector The LED will be ON to indicate a ready condition The LED will be flashing whenever data is coming in from the main control box or when the unit is busy preparing for printing Print Each load or delivery will automatically be kkkkxkkkkkkkkkkkkkkkkkkkkkkxkkk ID 1911 printed after the Date Sep 01 2000 transaction is complete START AT 2000 KGS The print button is used Teste LOAD 2009 KGS nt dail 25 MIN 162 KG MIN to print daily 15 03 DELIVERY 3623 KGS transaction reports and 23 MIN 160 KG MIN not to print individual 15 40 DELIVERY 2277 KGS 15 MIN 164 KG MIN transactions A sample Banna iro kee report 1s shown on the Se ee ee ee ee ee ee ee right The report is TOTAL LOADED 4000 KGS TOTAL DELIVERED 5900 KGS divided into sections by the ID which can be set Ge a a through the control box see the OnBoard Weighing System manual P N 42334 To print transactions from the previous day wait for the current day s transaction report to finish printing and press the print button again You may continue printing previous days until there are no more previous days left At th
5. NORAC 27 WEIGHING AND CONTROL SYSTEMS Canada United States NORAC Systems International NORAC Inc Inc TOLL FREE 1 800 667 3921 TOLL FREE 1 866 306 6722 306 664 6711 763 786 3080 SHIPPING ADDRESS SHIPPING ADDRESS 3702 Kinnear Place 1290 Osborne Rd NE Suite F Saskatoon SK Fridley MN S7P 0A6 55432 2892 For other service locations please view our website www norac ca Improving the Competitiveness of Industry and Agriculture through Precision Measurement Printed in Canada Copyright 2000 NORAC Systems International Inc Reorder P N 42337 MAN Rev C NOTICE NORAC Systems International Inc reserves the right to improve products and their specifications without notice and without the requirement to update products sold previously Every effort has been made to ensure the accuracy of the information contained in this manual The technical information in this manual was reviewed at the time of approval for publication Table of Contents 1 0 Introduction cc ccc ceccccccceeseccceceeeececeeeeeecsseeeeseeeseeaees 1 TC ECS a eck sat id case eal aloe he cask el ake alah ads eke Calg 1 Packa Cr sistent aes ora mice nanan EENE EATE EEEIEE 2 2 0 Installati n a a E a R at aie 3 Header Frame essesesseseessresesrrrrsssrrresesrreresrreressrrrrseseeeree 3 Printer Connection esssseseessesrcersssrceeseseteresreereesrrerseseeeree 4 Data Capture Module eesseesessesrcessesrrressrrerresrrersesrrrres 5
6. ckage consists of a header frame unit and the removable module as shown below The header frame is installed in the printer compartment of the OnBoard control box Header Frame Figure 1 Basic Package 2 0 Installation Header Frame The header frame should be mounted on the left side of the ticket printer in the control cabinet The front edge will fit between the bottom foam and the front panel The back edge will fit between the back foam and the bottom foam A self tapping screw may be used to secure the front edge of the header frame to the panel of the control cabinet Printer Plug Control Box Plug Front Figure 2 Header Frame Printer Connection Disconnect the existing printer cable from the top of the printer compartment Re connect the printer cable to the panel mount connector on the header frame Connect the in line cable from the header frame to the original printer socket at the top of the printer compartment Figure 3 Connecting the System Insert paper into the printer and push the START button on the OnBoard control panel Printing should occur if the cable has been connected properly Data Capture Module NOTE Before installing or removing the Data Capture Module ALWAYS power down the system first One end of the Data Capture Module has a printed circuit board edge connector After powering down slide the edge connector into the header frame guide and push it all the way in until
7. is point the printer will print NO TRANSACTIONS FOUND Before printing a report make sure there is enough paper To give you time to change paper the module will wait up to three minutes for you to print a previous day before resetting to print the most recent transaction day turning the power OFF then ON will also do this NOTE The module will automatically skip days on which there were not any transactions NOTE You may not print in the middle of a transaction Reset To clear all the stored transactions put a piece of paper into the printer Use a small pencil eraser or the handle of a small screwdriver to push on the recessed Reset Button through the hole opening The button should be pushed for 2 seconds The LED will flash to indicate clearing in progress When the clearing is done it will print Clearing done Version XX to the printer Jack In order to upload the stored information to a PC the removable module must be removed from the header Power must be supplied to the module through the jack A 110Vac to 9Vdc adapter is provided with the option kit A snap cap is provided to cover this hole opening D Connector The removable module can be connected to a PC communication port using a null modem cable supplied with the PC Upload option through the D connector at the end of the module Figure 5 25 Pin D connector Computer 4 0 PC Upload Option 42343 The PC Upload Option allows y
8. ou to use the Data Capture Module to its full potential The Data Capture Module stores up to 500 transactions which can be transferred to a computer quickly and seamlessly The Data Capture Software included in this option will download all transactions at the click of a button and create a detailed customized report within seconds If your organization has multiple stations you can even generate station reports from headquarters And if you need that extra degree of freedom the Data Capture Software also allows you to export to most popular spreadsheet software such as Microsoft Excel where data can be converted into concise and meaningful graphs and charts among other things 0 x NORAC F If you would like to try amp Data Capture Settings Troubleshooting demonstration version of the software which does not actually communicate with the Data Capture Module please contact your NORAC Sales Representative The PC Upload Option includes e the following E rCommunications Communications with data capture module stopped To start uploading click on the cable e One null modem cable e One power adapter e PC Upload Software full version and Manual Refer to the Data Capture Software s user manual for details 5 0 Trouble Shooting NO POWER 1 0 If the Data Capture Module s LED is off when the power is ON for the NH3 system check that the module is plugged in completely
9. ranty merchantability or fitness for a particular purpose is hereby disclaimed This warranty is in lieu of all other warranties expressed or implied 11