Home

User Manual

image

Contents

1. 15 LightSpion user guide
2. Auto detect Extender short L Extenderlong W Ok 10 LightSpion user guide Lamp alignment The vertical alignment of the lamp is done atomically by the centred twin clamp holder and due to the shape of the lamps The clamps can also be inverted enabling smaller lamps easily to be fixed The location of the holder can also be move to facilitate different lamp types Position 1 Position 2 11 LightSpion user guide The horizontal position of the lamp should be placed so the illuminating part it is at the centre of rotation as shown belovv BD Centre of rotation I I I I I I I I I I I I I I I I I L Failing to align the lamp to the centre of rotation can affect the accuracy of peak candela value and the beam angle The lumen value is not noticeable affected of incorrect horizontal placement 12 LightSpion user guide Lamp connection The lamp to be measured is simply connected using the universal povver connector placed on the side of the goniometer base as shown below 13 LightSpion user guide Making measurements Measurement made using the LightSpion Extender is done in the exact same way as the when using the LightSpion vvithout the Extender attached Therefore please refer to the LightSpion user manual for further details 14 LightSpion user guide Specifications Coming soon Ordering information LightSpion Extender unne P N EXLIGSP001
3. the following items e Goniometer base e Center plate e LightSpion base plate 5 LightSpion user guide About this document This guide describes how to install and use the LightSpion Extender and how to align light sources to be measured 6 LightSpion user guide Installation Software installation Light Inspector software Before you can start using the LightSpion Extender the Viso Light Inspector software version 3 69 or higher must be installed to support the LightSpion Extnder LightSpion firmware During software installation of the Viso Light Inspector software is the firmware of the LightSpion also checked and automatically updated to version 2 02 or higher to enable communication with the LightSpion Extender Use the following link to download the latest version http www lightdataserver com software Viso9620Systems Ligh tinspector htm You can always check the version installed by selecting Help gt About The firmware version can also be checked by selecting Help gt Firmware information 7 LightSpion user guide Setting up the Extender The LightSpion Extender comes in 3 parts e Goniometer base e Center plate e LightSpion base plate The Extender can be set up in 2 ways Long configuration 12 Full length of 181cm from goniometer to sensor allowing for measurement of light sources up to 220mm in diameter Short configuration Reduced length of 114 cm from goniometer t
4. LightSpion Exte n d e r User guide Preliminary Last edited 2014 04 24 eoe SYSTEMS eee Dimensions Weight 7 5 Kg 2007 Viso Systems ApS Denmark All rights reserved No part of this manual may be reproduced in any form or by any means without permission in writing from Viso Systems ApS Denmark Information subject to change without notice Viso Systems ApS and all affiliated companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual Contents MOGUCOM oreraa a TERR 5 About the LightSpion Extender 5 Package CONntents RE RR EE Re Re kene 5 Aboul this AGCUIME TID se ater o ica ES at d 6 Insioliolio n se SE EE tn eee he tet ec tutte cient MOREM DE 7 Software installations 7 Setting up the Extender iese esse see ee Ee ee ee Ee ee ee 8 LightSpion alignment i 9 Connecting the Extender ee ave vene rena 10 Lamp GAMEN sk ek Bos ee ee Bar 11 Lamp CON OC LOT m Mr cc 13 Making measurements onsen ER Ee RE eee 14 SPECITICAHONS OR E 15 3 LightSpion user guide Safety Information Warning This product is not for household use Read this manual before installing and operating the controller follow the safety precautions listed below and observe all w
5. arnings in this manual Preventing electric shocks Always ground earth the power supply Use only a source of AC power that complies with local building and electrical codes and that has both overload and ground fault protection If the controller or power supply are in any way damaged defective wet or show signs of overheating disconnect the power supply from AC power and contact Viso Service for assistance Do not install or use the device outdoors Do not spray with or immerse in water or any other liquid Do not remove any covers or attempt to repair the controller or power supply Refer any service to Viso Disposing of this product Viso products are supplied in compliance with Directive 2002 96 EC of the European Parliament and of the Council of the European Union on WEEE Waste Electrical and Electronic Equipment as amended by Directive 2003 108 EC where applicable Help preserve the environment Ensure that this product is recycled at the end of its life Your supplier can give details of local arrangements for the disposal of Viso products 4 LightSpion user guide Introduction About the LightSpion Extender The LightSpion Extender allows to measure light sources up to 220mm in diameter using a existing LightSpion measurement system The Extender is simply connected to the LightSpion and the Light Inspector software detects it automatically Package contents v The LightSpion package contains
6. o sensor allowing for measurement of light sources up to 135mm in diameter This configuration can be useful when measuring low power and smaller light sources where a shorter distance will increase the sensitivity of the sensor 8 LightSpion user guide LightSpion alignment The Extender base plate comes with alignment points and a visual outline for the LightSpion ensuring that the LightSpion is fixed at the right location for accurate measurements Visual outline Alignment points The alignment points clicks into bottom of the LightSpion as shown below 9 LightSpion user guide Connecting the Extender Connecting the extender is simply done by unplugging the build in goniometer and da connecting the RJ45 of the Extender goniometer The power going to the build in goniometer lamp holder must also be unplugged and power to Extender is connected instead The Light Inspector software will automatically detect the Extender and the configuration can be seen in the photometric window M l 181c AM 114 fl Sensor Vs E ic Sensor vie 4 Colour Colour ar Fi x 0 437 1 9 7 x 0 437 CIE1931 y 0 416 CIE1931 y 0 416 Long configuration Short configuration In case the system does not detect the Extender due to outdated hardware is it possible to select it manually in Setup gt Options _ Restore defaut Select folder Goniometer type