1. lead acid gel cell Voltage capacity 6V 1 2AHr Temperature compensation 10 C to 70 C Operating time Normal approximately 10 hours Low power approximately 3 months Internal Backup Battery For real time clock and internal data storage backup Type 3V 1 2AA Lithium Physical and Environment Construction Powder coated fabricated steel Physical dimensions 260 x 110 x 85mm height 104mm with PC Card Weight 2 2kg 4kg shipping Environment temperature range 45 C to 70 C Humidity 85 RH non condensing Accessories Included Line adaptor 110 240Vac 500mA Comms cable for PC with 9 to 25 pin adaptor Resource CD which includes standard software Manuals Getting Started with datalaker User s Manual Options amp Accessories Channel Expansion Module CEMS3 Multiplexer relay Number 2 per DT500 Series unit Channel number 10 two wire 30 two wire shared terminals 20 digital inputs 10 digital outputs 5 with relay contacts Portable Carrying Case PE500 Capacity 1 DT500 range unit 1 x CEMS3 Requires AS1072 Environmental protection IP66 SRAM PC Card MC1024P MC4096P Capacity 1MByte approximately 340 000 data points 4MByte approximately 1 390 000 data points DeLogger 4 Pro Graphical programming and supervision software Supports a large network of DT500 range units connected via modem Features include comprehensive plotting reporting mimics database web publishing and
2. other powerful capabilities datalaker TS 0044 B3
3. 0 00 uV 500 Q 2 50 MQ 2 50 Vdc 200 00 uV 5 000 Q 25 00 mO 100 0 Vdc 500 00 uV 100 Hz 0 01 0 25 mA 0 20 pA 10 kHz 0 01 2 50 mA 1 00 pA 25 00 mA 10 00 pA 100 Vdc range of DT505 and DT605 only Accuracy Measurement at 251 45 C to 60 C DC Voltage 0 15 0 25 DC Current 0 25 0 35 DC Resistance 0 20 0 30 Multiplexer Channel Selector DT500 and DT600 solid state 5V input range DT505 and DT605 _ relay 100V input Input impedance 1MQ or gt 100MQ programmable Common mode range DT500 and DT600 DT505 and DT605 Sampling Sampling for accuracy and noise rejection by integrating over 50 60Hz line period Maximum sample speed 25Hz up to 70Hz without noise rejection Effective resolution Linearity 0 01 Common mode rejection 25mV range gt 90dB Line 50 60Hz series mode rejection gt 35dB Sensor Excitation Each channel 4 5V 250uA or 2 5mA DC voltage 5V at 100mA max switched Internal Channels Temperature thermocouple reference junction 1 Reference voltage channels 1 Internal battery voltage 1 Sensor Support Supports a wide range of sensors types including but not limited to the following Thermocouples Types B C D E G J K N R S T Reference junction compensation accuracy 3 5V 100V on 100V range 15 bits Case temperature 215C 20 to 60 C Accuracy 1 0 C 15 C RTDs Types Pt Ni Cu Resistance range 10Q to 2kO Measure
4. DI500 amp datalaker DT600 Range Intelligent Data Logging Products e General Purpose Low Power Data Logger e 10 30 Sensor Channels 7 Digital Channels e Unique Universal Channels e Up to 1 390 000 Data Points e Stand Alone and Real Time Data Acquisition e Remote Monitoring and Control e Removable Screw Terminals e Expandable The datalaker DT500 amp DI600 Range The datalaker DT500 range of general purpose battery powered data acquisition and data logging systems measure inputs from most sensor types Data can be conveniently and securely stored in battery backed RAM and removable memory cards The datalaker DT500 range consists of four models DT500 DT505 DT600 DT605 The DT500 and DT600 models have Solid State Channel Selectors Low Voltage The DT505 and DT605 models have Relay Channel Selectors High Voltage The DT600 and DT605 both have an integral display and keypad that allows users to view channel data alarm status and system information including time battery status and amount of data stored Programmable function keys allow keypad control over the unit s operation Applications include e Fault Finding e Automotive Testing e Temperature Profiling e Weather Stations e Flood Warnings e Research amp Development FREE Software amp Technical ae l l Support e Process Monitoring Machine Down Time Load Cells e Building Monitoring Strain Guages datalaker software an
5. d Resource CD The datalaker Resource CD is provided FREE with every new logger It contains software to enable easy setup fast download real time viewing of data and direct export to excel spreadsheets The Resource CD also contains helpful training videos manuals application and technical notes and other valuable utilities DeLogger 4 Pro is the enhanced graphical package including additional automation reporting database and remote datalaker management features For your nearest local Datataker distributor visit www datataker com Australasia Europe Americas Datataker Pty Ltd Grant Instruments Cambridge Ltd Computer Aided Solutions 7 Seismic Court Shepreth 8588 Mayfield Rd Suite One Rowville Melbourne Cambridgeshire Chesterland OH 44026 Victoria 3178 SG8 6GB Tel 1 800 9 LOGGER Tel 61 3 9764 8600 Tel 44 0 1763 264780 Tel 1 440 729 2570 Fax 61 3 9764 8997 Fax 44 0 1763 262410 Fax 1 413 375 6137 Email sales datataker com au Email sales datataker co uk Email sales computeraidedsolutions com www datataker com Analog Channels Channel Number Number of input channels depends on sensor wiring configuration Sensor configurations may be mixed Two wire with one shared terminal 30 Three and Four wire 10 Expansion by Channel Expansion Modules CEM Fundamental Input Ranges Full Scale Resolution Full Scale Resolution 25 00mVde 2 00 pV 500 25mQ 250 0 mVdc 2
6. digital event Conditional scanning while digital input high Time based scheduling from seconds to months in increments of 1 second 1 minute 1 hour and 1 day Maximum scheduled rate typically 25 samples per second Dynamic scan time base change yes Maximum number of channel entries 110 Alarms Condition high low within range and outside range Delay optional time period for alarm response Actions set digital outputs execute any datalaker commands Alarms can be combined in a logical fashion Data Storage Internal Type battery backed SRAM Capacity 166 530 data points PC Card Types SRAM up to 4MByte Type 1 Card voltage 5V types Capacity up to 1 390 000 data points Data format proprietary Download Data Format Format ASCII floating point fixed point or exponential formats Compatibility spreadsheets word processors graphing packages statistical programs and SCADA software Serial Interface RS232 The DT500 range are programmed and data extracted via the RS232 serial interface Speed 300 to 9600 baud 9600 default Handshake XON and XOFF Wake from sleep yes Isolation 500V Compatibility computers modems satellite modems radio modems and printers cE trademarks of Datataker Pty Ltd Manufactured and designed in Australia Warranty Equipment manufactured by Datataker is warranted against faulty materials or workmanship for three years For repairs carried out under warrant
7. ment accuracy 4 wire 0 15 of resistance value 3 wire 0 25 of resistance value Monolithic Temperature Sensors Types supported LM34 LM35 AD590 Thermistors Types YSI 400xx Series Resistance range lt 7kQ lt 20kQ with parallel resistor Bridge Sensors Configurations 4 wire and 6 wire Bridge completion external or internal half bridge 4 20mA Current Loops Shunt value 1000 to a shared common Accuracy 0 25 at 25 C Sensors Comments A wide range of sensor scaling and linearising facilities is provided including polynomials expressions and functions Digital Channels Number of channels Bi directional channels 4 Dedicated counter channels 3 Digital Input Number 4 shared with output channels Input Type logic level protected and 5kQ pull up to 5V Counter Channels Number 4 low speed 10Hz shared with input channels 3 high speed 1kHz sleep mode with switchable internal clocking options Size 16 bit 65 535 counts Digital Output Number 4 shared with input channels Output type open collector npn transistor Rating 30V 100mA Calculation Channels Any expression involving variables and functions including sin cos tan asin acos atan abs sqrt average maximum minimum time of max time of min variance integral histogram Scheduling of Data Acquisition Number of schedules 4 acquisition schedules 1 immediate schedule 1 alarm schedule Scan triggers time base or
8. y no charge is made for labour materials or return carriage All non Datataker manufactured products are covered by original manufacturer s warranty Quality Statement Datataker operates a Quality Management System complying with IS09001 2000 It is Datataker s policy to supply customers with products which are fit for their intended purpose safe in use perform reliably to published specification and are backed by a fast and efficient customer support service Trademarks dataTaker DeLogger DeTransfer DePlot are either registered trademarks or www datataker com 1 second or as fast as possible Your local distributor Network Interface Multiple datalaker only Standard RS485 Protocol proprietary with error correction Speed 1200 Baud Distance 1000 meter maximum System Display and Keypad Models on DT600 and DT605 only Type LCD 2 lines by 16 characters back light Display functions channels data alarms battery status data capacity Key pad 5 keys for scrolling function execution Beeper for alarms etc Indicator LED s 3 programmable Real Time Clock For time stamping of data scheduling and timers Normal resolution 1 second Accuracy 2 seconds per day 25 C Power Supply Voltage range 11 to 24Vdc or 9 to 18Vac Power Consumption In normal mode 1W 2W with battery charging Sleeping 2mW 350A from battery Typical low power operation 20mW Internal Main Battery Chemistry