Home
Installation Instructions - Snap
Contents
1. in back of unit ZEEAC307A1 03 26 1997 REV C Page 4 of 5 PREPARING NEW RECOVERY TANK 1 So ve AO Oy GN On 12 13 Referring to FIGURE 2 open the BLUE valve on Recovery Tank to release ALL COMPRESSED AIR Remove the Yellow Hose from the gauge set box OIL the seals on each end of hose Add the anti blow back valve 4519005501 or 4519005502 to the short side of yellow hose Attach open end of Yellow Hose to BLUE valve on Recovery Tank Refer to FIGURE 2 Attach other end of Yellow Hose with the anti blow back valve to the service port on back of unit Open ball valve on yellow hose Plug AC Cord to a 115VAC outlet Turn compressor switch to ON and turn the 3 way valve to VACUUM Pull a vacuum for about 15 minutes FIGURE 2 RECOVERY TANK Once completed turn the 3 way valve to OFF and the compressor switch to OFF Close Recovery Tank valve BLUE and remove Yellow Hose from Recovery Tank Re OIL seal on Yellow Hose and connect to center port on Gauge Set Place Recovery Tank on scale Tank fittings should face straight out the back of unit Connect the Yellow Hose from the bottom of unit to the purge valve A shown in FIGURE 3 on top of the Recovery Tank Connect the Red Hose from the bottom of the unit to the RED valve B on the Recovery Tank Connect the Tank Brace EASC076C10A C to the frame and secure with Wing Nuts 04070019 Slide the Temperature Lead between the Velcro Strap D
2. on the recovery tank Ensure that the velcro strap is 2 above the weld of the tank Top of Tank FIGURE 3 INSTALLING TANK ZEEAC307A1 03 26 1997 REV C Page 5 of 5 CHARGING RECOVERY TANK NOTE 10 11 THIS PROCEDURE IS USED TO SETUP THE UNIT FOR CHARGING RECOVERY TANK SHOULD HAVE AT LEAST A 25 VACUUM THIS PROCEDURE IS DONE WHEN RECOVERY TANK IS ON THE SCALE Be sure Recovery Tank valves B are closed Refer to FIGURE 4 Disconnect the Red hose from the Recovery Tank Disconnect and Re il both the seals on Yellow hose C Connect the long side of the Yellow Hose to the Virgin Tank Connect the short side of the Yellow Hose to the Red Valve on the Recovery Tank B Open the Red Valve on the Recovery Tank Invert the Virgin Tank A and open valve Open Hand Valve D on the Yellow Hose to allow the refrigerant to flow ce Raise the Virgin Tank to a higher level than the l Recovery Tank Gravity and vacuum will transfer the liquid refrigerant to the Recovery Tank faster than reclaiming it Refer to the LCD Display to view the amount of refrigerant that has been transferred After the desired amount of refrigerant has been ls transferred close valves on Virgin Tank and a Recovery Tank Set Virgin Tank on ground upright Close Hand Valve on Yellow Hose Disconnect Yellow Hose from Recovery Tank Re Oil seals on anti blow back valve on
3. the Red Hose from unit and connect to Recovery Tank Open Recovery Tank valve RED FIGURE 4 CHARGING TANK 12 Re Oil seal on Yellow Hose and connect to service 13 14 15 port on back of unit Open Hand Valve on Yellow Hose Plug the unit into a 115VAC outlet Turn the compressor switch to ON and the 3 way valve to RECYCLE This will reclaim the refrigerant from the hose Optional Opening Virgin Tank valve will recover the rest of the refrigerant Once complete disconnect Yellow Hose from Virgin Tank Re Oil seals on Yellow Hose and connect to center port on Gauge Set REMEMBER TO OIL O RINGS AND SEALS WHEN ATTACHING HOSES OR FITTINGS INSTALLATION COMPLETE SETUP COMPLETE ZEEAC307A1 03 26 1997 REV C
4. ECO 12 EEAC307A ECO 134 EEAC308A UNIT SETUP 1of5 Installation Instructions INSTALLATION MUST BE PERFORMED BY QUALIFIED SNAP ON EQUISERV PERSONNEL ONLY INSTALLATION OVERVIEW The Installation Procedures listed are for the Snap on ECO units EEAC307A for R 12 amp EEAC308A for R 134a The unit is shipped as a fully assembled unit with the exception of the items listed in the Parts amp Accessories per tester PLEASE READ THESE INSTRUCTIONS COMPLETELY BEFORE SETTING UP UNIT A CAUTION THIS UNIT MUST BE PLUGGED INTO A PROPER AC OUTLET FOR UNIT TO OPERATE CORRECTLY REFER TO THE UNIT ID PLATE LOCATED ON BACK OF UNIT EXTENSION CORDS ARE NOT RECOMMENDED BUT IF AN EXTENSION CORD MUST BE USED USE A CORD THAT IS LESS THAN 50 FEET WITH A 16 AWG OR ABOVE 50 FEET AND LESS THAN 100 FEET WITH A 14 AWG A WARNING USE STANDARD REFRIGERANT HANDLING SAFETY PROCEDURES WHEN PERFORMING INSTALLATION ALWAYS WEAR SAFETY GOGGLES DON T SPILL OR TOUCH LIQUID REFRIGERANT AVOID FLAMES AND EXCESSIVE HEAT USE ONLY IN WELL VENTILATED AREA ZEEAC307A1 03 26 1997 REV C Page 2 of 5 PARTS amp ACCESSORIES FOR EEAC307A PART NUMBER 04070019 0647019601 0647019701 0647019901 0647020001 0692183401 0692191401 0692192801 0692224201 0692229101 1285 4519005501 EAA0157C00A EAH0013C00A EASCO76C10A SS1450VHS ZEEAC307A ZEEAC307A1 DESCRIPTION Nut Wing Adapter GM Adapter Quick Disconnect GM Ford Adapte
5. et box D Remove accessory and tank boxes C E and packing material F from scale tank compartment From the back side of the unit carefully lean the unit backwards and roll off the bottom runner assembly G Inventory all items using the Parts amp Accessories list and inspect for damage FIGURE 1 Unit Package PARTS 8 ACCESSORIES SETUP 1 af oO DN Remove the Gauge Set Assembly EAH0013C00A or EAH0014C01A from the gauge set box and place on gauge set bracket Bracket is part of rear panel Remove the Blue and Red Hoses from the gauge set box and OIL the seals on each end Connect the open end of the Blue and Red Hoses to the Gauge Set respectively Remove the Beaker 1285 and place it in the hole next to the left rear wheel For the EEAC307A place the four adapters in the beaker This is only a temporary place until the customer finds a more suitable location For the EEAC308A connect the Red and Blue adapters 0647028707 and 0647028708 to the Red and Blue Hoses from the Gauge Set respectively For the EEAC308A place the O Ring Kit EAK0027C00AS and Adapter Fitting 115080 on the bottom foot panel Remove the User s Manual MAC Form Certification Product Registration Form Warranty Registration and Video Tape from the box Hand these items to the Owner or Manager Remove Recovery Tank EAA0157C00A or EAA0158C00A from its box Remove cardboard wrap from Recovery Tank Seton floor
6. r Quick Disconnect Large GM Adapter Ford Questionnaire SEL 1403C MACS Form Mail in Product Registration Form MACS Certification Form Product amp Warranty Registration Form Beaker Disposable 5oz Anti Blow Back Valve Recovery Tank Assembly Gauge Set Uniweld Brace Tank Video Tape User s Manual Installation instructions PARTS amp ACCESSORIES FOR EEAC308A PART NUMBER 04070019 0647028707 0647028708 0692183401 0692191401 0692192801 0692224201 0692229101 115080 1285 4519005502 EAA0158C00A EAHO014C01A EAK0027C00AS EASCO76C10A SS1450VHS ZEEAC307A ZEEAC307A1 DESCRIPTION Nut Wing Adapter Vehicle High Side Adapter Vehicle Low Side Questionnaire SEL 1403C MACS Form Mail In Product Registration Form MACS Certification Form Product amp Warranty Registration Form Adapter Low Side Beaker Disposable 5oz Anti Blow Back Valve Recovery Tank Assembly Gauge Set R134a Kit Vehicle Adapter O Ring Brace Tank Video Tape User s Manual Installation Instructions REQUIRED TOOLS e Safety Goggles 0001 5005 e Refrigerant Oil Mineral or Superlube 0681 0193 02 or 03 ZEEAC307A1 03 26 1997 REV C oo ooo Stl Arr BoA Brn tintn nnn ni ip lt lt Page 3 of 5 INSTALLATION INSTRUCTIONS 1 a fF oO DN Open top of box A Split one corner and unwrap box A off unit Remove the protective pad B Remove the plastic bag from unit Remove the gauge s
Download Pdf Manuals
Related Search
Related Contents
4032 630 004 0f MBA TC42 de,en,fr,nl ME 27.03 - NEC Display Solutions Europe Samsung DVR SHR-2040 User's Manual MULTÍMETRO DIGITAL Bulletin Technique Teclado Ejecutivo Axim con tecnología inalámbrica Bluetooth NetworX V3 Installation Manual Dutch User Manual MIOe-DB5000 Copyright © All rights reserved.
Failed to retrieve file