1. Press again A if a second angle is required Enter the second angle set value Press START Run output is activated but waitthe Ready input saw head raises to top position When the saw angle positioned at wanted position the controller sets the outputs to move to the desired angle As it reaches a distance from its destination equal to Pr 4 it will drop the high speed output and the drive will move with slow speed to the desired angle when set angle is reached run outputs are deactivated Note Output Zone relay closes if angle pos is negative or at the Main screen Set Speed Press S when the display shows main screen Enter the sawing speed set value Press START New set value is taken to 0 10V analog output 1 2 4 Press 1 2 4 5 for quick speed change u 2 4 1 SET HEAD HEIGHT Set Height Press H when the display shows main screen Enter the height set value Press START 1 Output relay H LMT contacts closes if the head position passes over this soft limit value INot2 f the entered limit value is greater than the existing head pos Output H OUT relay contacts closes 1 sec to bring the head to this new position 4 2 SAW HEAD POSITION TEACH su Press sH when the display shows main screen The existing height of the saw head is teached to the controller and shown on the display 5 1 PROGRAM SELECT 3
2. programs Press or P2or P3 when the display shows main screen The recalled programs contains the stored set values Pe for angle height and sawing speed 5 2 PROGRAM TEACH EA Press or P20rP3 for 3 sec when the display shows main screen Bsn till its led is off Pe Angle Height and speed writes to memory 3sn 5 6 PARAMETERS Press 0 when the display shows main screen Enter password 1971 Press START Enter the parameter no cesses Press START Enter the new parameter value x Press START Repeat the same for the other parameters Press STOP two times to exit e Press START to save the entered values lt START gt Save elle lt STOP gt Don t Save Press STOP to exit paramerters without any change Www Range Factory e 1 Angle Mul Angle encoder multiplier 1 9999 541 2 Angle Div Angle encoder divider 1 9999 6396 3 Angle Tol Angle tolerance 0 1 9 9 0 1 4 Angle Slow Angle Slow distance 0 1 99 9 4 0 5 Angle Min Angle Min Set value 60 0 60 0 60 0 6 Angle Max Angle Max Set value 60 0 60 0 60 0 1 Angle Rst Angle Reset value 60 0 60 0 60 0 8 Angle 2 Clamp pos at the zero angle 0 1 0 9 H Set Min Head pos min limit 0 999 10 H Set Max Head pos max limit 450 H Reset Head height Reset value Speed Min Saw speed min set Speed Max Saw spee
3. Max31 Saw Full Automatic Saw Controller B Max31Saw BMSY 440DGH NC 10 30 1 50 gt 30 O gt 20 P Helef y S 100 0001 Operating Manual MAX31SawV10UMR1EN CDR 0916 rev 1 0 2 Axis Control Encoder feedback 2 speed positioning Manual ve Auto positioning 3 quick program buttons Analog output 0 10V for sawing speed LCD graphic display 128x64 dot Help button Service display Real time clock User friendly Removable memory module 1 1 FRONT VIEW V Max31saw 1 2 KEYPAD START Ok FFF STOP Cancel M MANUAL Angle AUTO Angle HEIGHT H HIGHT TEACH H h 1 PROGRAM Angle height Speed 2 PROGRAM 3 PROGRAM SAW SPEEDI 0 10V CLS Counter Reset EN IIIS PRI 1 SPEED 10 if main screen ANGLE FAST FORWARD if manual mode 2 SPEED 1 if main screen HELP ANGLE SLOW FORWARD if manual mode 4 SPEED 10 if main screen ANGLE FAST BACKWARD if manual mode 5 SPEED 1 if main screen ANGLE SLOW BACKWARD if manual mode 9 SERVICE 0 PARAMETER SIGN 2 1 MANUAL ANGLE fw H Ls 2 2 AUTO ANGLE Press M when the display shows main screen Press to move forward fast Press to move forward slow Press to move backward fast Press move backward slow Press STOP to exit 3 SAW SPEED Press A when the display shows main screen Enter angle set value
4. NP 11 PE Protective Earth 9 NEXT NextAngle Count Input 12 12V Encoder Supply 12VDC 1 A Encoder A A Encoder Angle 14 B Encoder B 11 PE Protective Earth 15 OV Encoder Supply 0V 12 H Encoder Supply 12VDC 13 A Encoder A Uther 14 B Encoder B 33 H LMT Height Limit NO 15 0V Encoder Supply OV 34 ZONE Clamp Pos Close Negative Es 35 Common Angle Axis Outputs 36 H OUT Height change out NO dm Angle Forward 37 H OUT Height change out NO Angle Backward ess Slow Fast Slow Fast RUN out CC RUN out NOTE STOP input must be shorted to common if itis not used
5. ctual value and angle height positions are displayed on the screen 8 SERVICE MENU Press 9 when the display shows main screen OFF ON and keep pressing and switch on the supply bdo ats LEE Encoder A Encoder H Digital inputs P selected are activate 3 Press 3 to enter the date and clock S 5 STOP 6 READY Encoder 7 A RST real counter H RST 5 9 NEXT CONNECTIONS and PANEL CUT OUT DIMENSION r 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 i x S W lt m wees u 1608090 E lax31 Saw BM1 N toe e v1 0 3 m miss RS232 j vo LS Hencooer eum Mes 24 VAC DC s D INPUTS PNP A ENCODER A CONTROL RUN 5 gt r r gt G O u u 5 a lt m o DE nc t1 12 13 14 15 16 17 18 19 20 21 22 B MM 1 Protective Earth 23 GND RS232 0V 2 N 24V AC DC 15 50Hz 24 RX RS232 Receive 3 L 24V AC DC 15 50Hz 25 TX RS232 Transmit 4 I 3COM 12V Common 26 AOUT 0 10Vdc Analog Out sawing speed 5 STOP Stop Input NC PNP 27 OV GND 6 READY Ready Input NO PNP 1 A RST Angle Reset Input NO PNP oder neat neig 8 H RST Height Reset Input NO P
6. d max set 14 SpeedOutMax Saw speed mm min for 10V out 0 999 120 15 Pass Password 0 9999 1971 NOTE Clamp pos at zero angle 0 atthe right 1 atthe left If this parameter is changed manual or auto positioning is needed EXFACT 0 11 Switch off the supply press 1 keep pressing 1 and switch on the supply keep pressing OF ov the display shows factory loaded 7 1 ANGLE CALIBRATION POSITION CORRECTION Press A for 10 sec when the display shows main screen PSS 10sec Enter the Password 1971 Press START Enter the new angle value Press START GAG 7 2 HEAD HEIGHT CALIBRATION Press H for 10 sec when the display shows main screen 10sec Enter the Password 1971 hal BE Press START Height Cal Enter the new head height value Press START GAG 7 3 AUTO CALIBRATION By switch on cal mode is asked For auto cal mode just press START to activate RUN output contact close signals PLC to rise the saw head to the top switch Then saw head movement stops and PLC send READY signal closes to saw controller to start angle positioning toward A RST siwtch Angle positioning outputs continue to be active for 1 sec after A RST switch is closed then positioning stops just at this moment calibration values pr 8 and pr 11 respectively are transferred as a