1. CHOICES House ID This prompt will only appear if the receiver is disabled If the receiver is enabled the FA570RF will use the House ID programmed in the panel Refer to the Application Guidelines on the previous page when selecting a House ID To program a House ID Enter 01 31 To disable the transmitter Enter 00 Note All devices that you want to receive status from the FA570RF must be set to the same House ID as the FA570RF refer to Table on Page 1 Press the x key to continue HOUSE ID XX 00 31 Enable High Security Mode Enter 1 to select High Security Mode Note If this mode is enabled the FA570RF will only recognize encrypted devices If this mode is disabled the FA570RF will recognize both encrypted and non encrypted devices Press the key to continue HIGH SECURITY OFF 1 ON 1 Enable 0 Disable Disable High Security Devices Press the key to skip this prompt and exit Program Mode Note If you need to disable encrypted devices refer to the Disabling High Security Devices section DISABLE HS DEV NO 1 YES 1 YES 0 NO f When operating the system in High Security mode the 5804BD wireless keys will still function If you want the system to recognize only encrypted wireless devices program only encrypted devices in the system ACTIVATING HIGH SECURITY DEVICES This following procedure should be followed if using High Security encrypted
2. Physical 7 3 4 W x 5 3 8 H x 1 1 8 D Current Standby 50mA 197mm x 136 5mm x 28 6mm ee Backlighting on and Wiring Refer to Table 1 Sounder on 150mA Range 200 ft 60 9 m nominal Display 2 x 16 alphanumeric supertwist LCD backlit Frequency 345 MHz Sounder Tone Generator Integrated Circuit fire alarm is loud pulsing Voltage 12VDC tone burglary audible panic alarm is continuous tone FOR DETAILS ON THE LIMITATIONS OF THE ENTIRE ALARM SYSTEM REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL BEING INSTALLED IN CONJUCTION WITH THIS DEVICE FCC STATEMENT This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User s Manual Unauthorized changes or modifications could void the user s authority to operate the equipment LIMITED WARRANTY Honeywell International Inc acting through its First Alert Professional Security Systems business Seller 165 Eileen Way Syosset New York 11791 warrants its products to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 36 months from the date
3. devices will momentarily display the serial number of the device STEP DESCRIPTION 1 Follow the normal procedure for programming the device into the control panel refer to the Installation Instructions for the device that you are programming Exit out of Programming Mode 2 Put the control panel in Go No Go Test mode See the Installation Guide for the panel being installed 3 Follow the instructions supplied with each wireless device to enroll the device in High security mode The FA570RF DISABLING HIGH SECURITY DEVICES This mode gives you the ability to disable high security on all wireless keys that have been enrolled in the FA570RF This is particularly useful if a user loses a wireless key MN Once high security encrypted devices have been disabled they will only operate if the FA57ORF is set to listen to both encrypted and non encrypted devices programming step 6 above To completely disable the devices they must be deleted from the control panel STEP DESCRIPTION DISPLAY CHOICES 1 After the keypad has been powered for at least 60 seconds hold down CONADDRESS XX 00 31 the 1 and 3 keys at the same time for 3 seconds The current keypad address will be displayed You cannot change the keypad s address at this point Press the key to continue 2 Delete High Security Devices Press the 1 key to remove all high DISABLE HS DEVP 1 YES security enc
4. First Alert eee EON o SECURITY SYSTEMS K14031 3 06 Rev C FA570RF Keypad Transceiver Installation and Setup Guide GENERAL INFORMATION The FA570RF keypad transceiver is a combination unit that combines the functions of the following devices e FA570KP Alphanumeric Addressable Keypad e 5881H RF Receiver e 5800TM Transmitter Module The FA570RF Keypad Transceiver may be used on any control panel that supports alphanumeric keypads and 5800 Series wireless devices FUNCTION KEYS refer to Figure 1 The A B and C keys are designed for use as panic keys e g fire police personal emergency etc or other special functions on certain control panels The D key may be used as a macro key or other special functions with control panels that support this feature This allows a single key to execute a preprogrammed series of system functions e g bypassing zones arming etc The A B C and D keys must be pressed and A A Y held down for at least two seconds to activate their programmed panic functions FEATURES e Supports wireless key transmitters e g 5804 and bi directional transmitters e g 5804BDV 5828 5828V e Supports wireless keys with high security encryption capability e g 5804E e Provides a nominal range of 200 for the RF transmitters some transmitters have a shorter range e Supports RF jam detection when the receiver is enabled e Capable of sending status signa
5. fire or otherwise or that the products will in all cases provide adequate warning or protection Customer understands that a properly installed and maintained alarm may only reduce the risk of a burglary robbery fire or other events occurring without providing an alarm but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a result CONSEQUENTLY SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING HOWEVER IF SELLER IS HELD LIABLE WHETHER DIRECTLY OR INDIRECTLY FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE REGARDLESS OF CAUSE OR ORIGIN SELLER S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER This warranty replaces any previous warranties and is the only warranty made by Seller on this product No increase or alteration written or verbal of the obligations of this Limited Warranty is authorized First 149 Eileen Way Syosset NY 11791 TTA THAN i Alert www firstalertprofessional com NS PROFESSIONAL Copyright 2006 Honeywell International Inc K14031 3 06 Rev C EEO STEMS
6. he case back The breakouts must be punched out using a screwdriver before mounting the case back b If desired wires may be strain relieved to the wire tie point on the inside of the case back with a tie wrap not supplied 3 Mount the case back to a wall or electrical box 4 Use the wiring table on the next page when connecting the keypad Wire directly from the keypad s terminal block to the terminal block on the control s PC board Wire functions are marked next to terminals See the control panel s Installation Instructions for more complete details o Wr GA HAH oo0000000 jaa a aalala a aalala a WIRING TERMINALS TO CONTROL PANEL Figure 2 FA570RF Wiring Details back cover removed 5 Reattach the keypad to its case back Attach the top of the keypad first and then press the bottom section down until it snaps into place securely 6 Peel off protective film on the LED panel and install the z keypad labels as required Table 1 Wiring Table Keypad Control Panel Wire Color A G Data Out Data In Green Aux Pwr GND Black Aux Pwr Red vY Data In Data Out Yellow APPLICATION GUIDELINES FOR THE FA570RF Use the following guidelines when planning an installation If And Then This is the only transceiver on the system You want to use both
7. ices In this case the wireless keys must be assigned to the same partition as the FA570RF On FA168CPS panels the FA570RF will use the House ID programmed in the panel for the partition to which it is assigned Wireless keypads can only be used on Partition 1 PROGRAMMING THE FA570RF Refer to the following procedure to program the FA570RF STEP DESCRIPTION DISPLAY CHOICES 1 Enter the program mode by pressing the 1 and 3 keys simultaneously for a few seconds within 60 seconds after applying power 2 Keypad Address Enter the two digit keypad address Press the x key to CONADDRESS XX 00 31 continue Notes 1 Refer to the control panel s installation instructions for the acceptable keypad addresses 2 On the FA1220CV and above the FA570RF s partition assignment must match the RF keypad partition assignment programmed in field 1 48 3 Receiver Enable Enter 1 to enable or 0 to disable Receiver Enable the RECEIVER 1 ON receiver if RF transmitters or wireless keypads are programmed into the ON 0 OFFI 0 OFF control and no other receivers are enabled Press the key to continue 4 Receiver Address If receiver is enabled enter the two digit receiver REC ADDRESS XX 00 30 address 01 30 Note Refer to the control panel s installation instructions for the acceptable receiver addresses Press the x key to continue STEP DESCRIPTION DISPLAY
8. ls Armed Ready etc to bi directional units such as 5804BDV and 5828 5828V e The FA570RF automatically times out the backlighting of all keypad keys UL The following 5800 series transmitters are not intended for use in UL installations 5802 5804 5804BD 5804BDV 5804E 5814 5816TEMP 5819 5819BRS 5819WHS 5828 5828V and 5850 INSTALLING THE FA570RF Locate the FA570RF in an area and at a height where it is convenient for user operation The FA570RF must be at least ten feet from the control panel to ensure proper operation of the RF receiver Mounting And Wiring The FA570RF has terminal blocks for connection to power and data wires Removing the keypad s case back provides access to the terminal blocks The FA570RF can be surface mounted directly to a drywall or to a single or double gang electrical box 1 To remove the case back insert a small screwdriver blade at a downward angle into Slot 1 and twist the right side pops up Insert the screwdriver blade at a downward angle into Slot 2 and twist the left side pops up Insert the screwdriver blade into right side narrow Slot 3 and twist Separate the case back from upper case Special Function FA270 001 V2 Case Back Figure 1 Removing the Case Back 2 Route wiring from the control panel through the large opening in the case back a If surface wiring is being used wiring may be routed through the top or the bottom left side breakout in t
9. rypted devices Press the key to continue NO ES 0 NO 3 If YES was selected in Step 2 the unit will display a confirm request to ARE YOU SUREP 1 YES delete the stored high security device Press the 1 key to accept z followed by the key to exit the programming mode NO ES 0 NO TROUBLESHOOTING The error messages listed in the following table causes the FA570RF to produce a single ding tone The table describes the error messages and the corrective actions Display Probable Cause Corrective Action Low Bat XXX XXX Low battery in the wireless key 1 Replace the battery if the wireless key has a replaceable transmitter zone number battery 2 Replace the transmitter if the wireless key does not have a replaceable battery Open Ckt No data is being received from the control Verify that the keypad Data in yellow wire is connected panel properly Check 09 1 The control panel does not see the 1a Verify that the keypad Data In yellow and Data Out green Check 1XX or FA570RF Receiver or the Receiver is not wires are connected properly Check 6XX functioning 1b Verify that the control s receiver address is correct XX device address of 2 Another device on the keypad terminals is 2 Verify the wiring connections between the control and all the FA570RF not communicating to the control panel other devices Note Message depends on control panel SPECIFICATIONS
10. stamp control on the product or for products not having a date stamp for 30 months from date of original purchase unless the installation instructions or catalog sets forth a shorter period in which case the shorter period shall apply Seller s obligation shall be limited to repairing or replacing at its option free of charge for materials or labor any product which is proved not in compliance with Seller s specifications or proves defective in materials or workmanship under normal use and service Seller shall have no obligation under this Limited Warranty or otherwise if the product is altered or improperly repaired or serviced by anyone other than First Alert Professional factory service For warranty service return product transportation prepaid to First Alert Professional Factory Service 165 Eileen Way Syosset New York 11791 THERE ARE NO WARRANTIES EXPRESS OR IMPLIED OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT Seller does not represent that the products it sells may not be compromised or circumvented that the products will prevent any personal injury or property loss by burglary robbery
11. the receiver and transmitter function on a single partition system Set the keypad to a device address assigned to the desired partition e Enable the receiver e Program a system House ID in the control panel this will enable the transmitter function e Set the wireless devices that will communicate with this FA570RF to the same system House ID There is another You want to use only Set the keypad to a device address assigned to the desired partition receiver or the transmitter Disable the receiver t i f ti aa on Hoe Aah oma second e Program a DIFFERENT House ID in the FA570RF than is programmed in the e system partition control panel e Set the wireless devices that will communicate with this FA570RF to the same E LE House ID as the FASZOR You want to use only e Set the keypad to a device address assigned to the Partition 1 Ai S i e Disable the receiver OTO TA aS e Program a House ID in the FA570RF that matches the system House ID partition system f programmed in the control panel e Set the wireless devices that will communicate with this FA570RF to the same House ID Notes On FA1220CV panels and above wireless keypads e g 5828V can only be used on a single partition This partition is programmed in field 1 48 and must match the partition assigned to the FA570RF Wireless keys can be used on more than one partition using a House ID programmed in the FA570RF and the dev
Download Pdf Manuals
Related Search
Related Contents
Tusk Handlebar Grip Heater Kit Instructions 特選中古車情報!! PSC-Rシリーズ 活用ガイド Audiovox APS57E Warranty Card Wire Grind Advanced Noise Gate v1.8 AN731 national radio astronomy observatory green bank, west virginia Copyright © All rights reserved.
Failed to retrieve file