1. PASSWORD MAIN MENU LANGUAG E ENGLISH lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt 1 lt DOME SETTINGS gt lt CAMERA gt lt MOTION gt RESTART FACTORY DEFAULTS HELP EXIT DOME SETTINGS lt IR LED gt lt IDLE gt lt ALARM gt lt PRIVACY MASK gt lt CLOCK gt Ze lt PASSWORD gt lt DOME TITLE gt lt ADVANCED gt lt OTHERS gt BACK EXIT PASSWORD lt EDIT PASSWORD gt ENABLE OFF BACK EXIT The dome features password protection function to prevent unanthorized changes to the dome settings If the PASSWORD function is enabled the operator can not access any dome setting without entering a valid password EDIT PASSWORD Move the cursor here and press IRIS OPEN to enter Please under the old password before set up the new password The initial password is 111111 ENABLE Move the cursor here and press IRIS OPEN to enter Move the joystick to select between ON and OFF The user need to enter the password when opening the OSD under the status of ENABLE ON 33 DOME TITLE MAIN MENU LANGUAG E ENGLISH lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt L lt DOME SETTINGS gt lt CAMERA gt lt MOTION gt RESTART FACTORY DEFAULTS HELP EXIT DOME SETTINGS lt IR LED gt lt IDLE gt lt ALARM gt lt PRIVACY MASK gt lt CLOCK gt lt PASSWORD gt lt ADVANCED gt Ze lt OTHERS gt a BACK EXIT OTHERS
2. The user can open and close the IR LED manually and set up the IR LED work mode under this OSD mean Under normal operation mode the user can press IRIS OPEN and IRIS CLOSE to adjust the IR LED power 1 CONTROL MODE AUTO IR LED will be opened or closed automatically according to the light conditions TIMING LED will be adjusted according to Open and Close Time OPEN IR LED forcedly open CLOSE IR LED forcedly close CAMERA IR LED status Open Close will be synchronized with Camera day and night switching 2 SENSITIVIRY Here the user can manually set the sensitivity from 1 5 The smaller the number is the lower light of the environment will be when the IR LED on 3 IR LED POWER Here the use can choose the power mode covering NORMAL MATCH and USER NORMAL Near IR LED will be turned on when wide angle and Far IR LED will be turned on when small angle MATCH The Near and Far IR LED will be turned on and off automatically to match the zoom in and out USER The user can manually adjust the Near and Far IR LED 4 AUTO CONTROL When it is on the IR LED will turn its power consumption to the standby status which will effectively extend the service life of IR LEDs And under this mode when objects appear in the screen the IR LED will turn its power consumption back to the normal status 5 STANDBY POWER When the AUTO CONTROL is on the user can set up the standby power here 6 STANDBY DELAY Set up how long
3. CAMERA SETTING The user can make adjustment for the cameras under this menu FOCUS MODE AUTO FOCUS allows the camera lens to remain in focus during zooming in zooming out and pan tilt movement Move the cursor here and press IRIS OPEN to enter Setup the mode AUTO or OFF and press IRIS OPEN to confirm When auto focus is off the user needs to do manual focus DIGITAL ZOOM Move the cursor here and press IRIS OPEN to enter Setup the function to be ON or OFF BACKLIGHT Move the cursor here and press IRIS OPEN to enter Setup the function to be ON or OFF PICTURE FLIP To set up the Tilt flip for the dome Move the cursor here and press IRIS OPEN to enter Setup the function to be ON or OFF FREEZE If turn on this function the screen image will be frozen until it is turned off Move the cursor here and press IRIS OPEN to enter Setup the function to be ON or OFF ZOOM SPEED To set up the zoom speed of Low Normal and high when doing the zoom in and out Move the cursor here and press IRIS OPEN to enter Move the joystick to choose and press IRIS OPEN to confirm DAY NIGHT To set up the day and night mode of AUTO CLOUR and B W Move the cursor here and press IRIS OPEN to enter Move the joystick to choose and press IRIS OPEN to confirm 43 CAMERA ADVANCED MAIN MENU LANGUAG E ENGLISH lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt lt DOME SETTING
4. OSD Menu Operations Call Preset 95 to enter the main OSD menu or call preset No 1 two times continuously within two seconds Control the joystick to move the cursor around the menu Press Iris Open to enter the menu for selections Dip Switch the joystick up and down to select the item Press Iris Open to confirm the selection Press Iris Close to cancel the selection Note If your controller does not have a joystick use the up or down key 4 OSD Menu Functions 23 MAIN MENU LANGUAG E ENGLISH lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt lt DOME SETTINGS gt lt CAMERA gt lt MOTION gt RESTART FACTORY DEFAULTS HELP EXIT 24 SYSTEM INFORMATION DOME ID 1234567890 ADDRESS 001 BAUDRATE 9600 N 8 1 PROTOCOL PELCO P TEMPERATURE 31C ALARM 000000 00 lt OTHERS gt BACK EXIT DISPLAY DOME TITLE OFF PRESET 5 SEC MOTION 5 SEC ZONES 5 SEC DATE TIME ON PAN TILT 5 SEC lt OTHERS gt lt DISPLAY POSITION gt BACK EXIT DOME SETTINGS lt IR LED gt lt IDLE gt lt ALARM gt lt PRIVACY MASK gt lt CLOCK gt lt PASSWORD gt lt DOME TITLE lt ADVANCED gt lt OTHERS gt BACK EXIT CAMERA SETTING AUTO FOCUS ON DIGITAL ZOOM OFF BACKLIGHT OFF FREEZE OFF ZOOM SPEED NORMAL DAY NIGHT AUTO lt ADVAN CED gt BACK EXIT MOTION lt PRESET gt lt SCAN gt lt SEQUENCE gt lt PATTERN gt
5. lt ZONES gt lt TIMING ACTION gt lt MOTION DETECT gt lt AUTO TRACKING gt BACK EXIT LANGUAGE MAIN MENU ZL A NOU AO E ENGLISH lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt lt DOME SETTINGS gt lt CAMERA gt lt M OTION gt RESTART FACTORY DEFAULTS HELP EXIT The language for the on screen menus is Selectable To change the display language Press Iris Open to enter selection All on screen menus are changed to the selected language 29 SYSTEM INFORMATION MAIN MENU LANGUAG E ENGLISH IF lt SYSTEM INFORMATIONS lt DISPLAY SETUP gt lt DOME SETTINGS lt CAMERA lt MOTION gt RESTART FACTORY DEFAULTS HELP EXIT SYSTEM INFORMATION DOME ID 1234567890 ADDRESS 001 BAUDRATE 9600 N 8 1 PROTOCOL PELCO P TEMPERATURE 31C VOLTAGE 12 0V ALARM 000000 00 gt lt OTHERS gt BACK EXIT OTHERS TITLE DOME VERSION V26200 DATE 2011 01 01 TIME 10 20 00 Ir TEMP SCALE CELSIUS BACK EXIT The user can check the dome system information as required The system information includes Dome ID dome address baud rate protocol temperature voltage alarm info dome title version date time and temperature scale Use the following steps to display the System Information screens 1 Use the joystick to position the cursor along the SYSTEM INFORMATION 2 Press Iris Open The SYSTEM INFORMATION screen opens 3 Mover the joystick up and town to select
6. Open to enter the item Move the joystick select the status and press Iris Open to confirm Titles can be placed anywhere on the monitor This feature allows you to customize the window of your monitor screen To set a DISPLAY POSITION lt DATE TIME gt title position lt DOME TITLE gt lt ZONES gt lt MOTION gt 1 Use the joystick to position the cursor in the DISPLAY POSITION lt ALARM gt 2 Press Iris Open lt PAN TILT gt 3 Use the joystick to move the title up down left or right BACK 4 Press Iris Open 7 EXIT 5 Repeat steps 1 through 4 to position other titles 6 Position the cursor at BACK or EXIT Press Iris Open to save settings and exit menu 27 IR LED MAIN MENU LANIGUAG E E MGL ISH lt SYSTEM INFORMA TION gt lt DISPLAY SETUP gt UF DOME SETTINGS gt lt CAMERA gt MOTION gt RESTAR FACTORY DEFAULTS HELP EKI DOME SETTINGS lt lRi LED I E gt lt ALARM gt lt PRIVACY MASK gt LLOCK gt PASSVWVORD gt lt DOME TITLE ADVANCED lt OTHERS gt BACK EXIT IR LED SETTING L CONTROL MODE AUTO SENSITIVITY barr 2 98 lt IR LED POWER gt AUTO CONTROL OFF AU TU CONTROL S ADVANCED gt m BACK ERIT IR LED POWER F POWER MODE USER BACK EXIT t IR AUTO CONTROL STANDBY POWER 60 gt LANDBY DELAY 10 SEC SENSITIVITY MID BACK EXIT i ADVANCED SET ENHANCED MODE STATIC START TIME 13 00 STOP TIME 06 00 BACK EXIT
7. P lt ADVANCED gt lt OTHERS gt BACK EXIT EXIT ADVANCED lt SOFT ADDRESS SET gt lt AUX gt T gt lt SOFT LIMIT gt lt DOME SPEED gt lt POWER ON ACTION gt lt CAMERA gt lt COMMUNICATION TEST gt LIMIT SETTING SOFT LIMIT OFF lt LEFT LIMIT gt lt RIGHT LIMIT gt LIMIT DELETE BACK EXIT The user can set up the soft limit to define the left and right boundaries for the pan movement SOFT LIMIT Move the cursor here and press IRIS OPEN to enter Move the joystick to select ON or OFF to enable or disable this function LEFT LIMIT Move the cursor here and press IRIS OPEN to enter Now the user can mover the joystick to control the PAN movement of the dome to a defined position for the left limit Press IRIS OPEN to confirm RIGHT LIMIT Move the cursor here and press IRIS OPEN to enter Now the user can mover the joystick to control the PAN movement of the dome to a defined position for the right limit Press IRIS OPEN to confirm LIMIT DELETE Move the cursor here and press IRIS OPEN to delete all the settings EE DOME SPEED MAIN MENU To make a selection of the dome speed the user can enter this LANGUAG E ENGLISH menu to set up lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt IF lt DOME SETTINGS gt Move the cursor to DOME SPEED and press IRIS OPEN to enter oe Move the joystick to select the dome speed when doing the pan RESTART movement FACTORY DEFAULT
8. Protocol through RS485 or coaxial cable e 8 auto scan with use defined left and right boundaries and settable scan speed e 8 Privacy Zones with defined English camera title e Auto Compatible PELCO_P PELCO_D compatible e Guard Location the dome will rotate back to preset position after a period of vacant time e Alarm triggering the alarm can trigger preset auto scan cruising and pattern tours functions e Soft Address Function the use can set up the dome address without uninstall the dome 2 2 Integrated Super Speed PTZ Rotator e Delicate stepping motor stable sensitive and accurate e 360 Pan and 90 Tilt range auto flip without blind area e Stepless speed change auto zoom speed matching e Near far IR Light auto matches camera zoom in out 2 3 Built in High Definition Day Night Camera e Auto iris auto back light compensation e Auto manual white balance e Auto manual brightness control e Auto manual focus e Multiple compatible camera brands including Sony Samsung LG CNB Sanyo etc 2 4 All weather Outdoor Design e 6 Inch High die cast alloy aluminum construction e High Precision Mould with high heat conductivity e Fully enclosed isolation design for heat sink e Nanometer Dustproof waterproof and fog proof lens e P66 Waterproof e 3000V lightning and surge current protection 2 5 Function Instructions e Focus PTZ Speed Auto Match The pan tilt rotation speed could be automatically adjusted acc
9. if there is not moving object the IR LED will turn into standby status 7 SENSITIVITY When the AUTO CONTROL is on the user can set up the sensitivity to detect the moving objects 8 ENHANCED MODE Under normal status press IRIS OPEN to enhance the IR LED power when it is turned to maximum press IRIS OPEN continuously for 2 seconds to enter the enhanced mode And the whole brightness of the image will be improved Move the cursor to EHNANCED MODE and press IRIS to enter and select between STATIC and DYNAMIC 9 START STOP TIME Set up time for IR LED to open and close under TIMING of control mode 28 IDLE MAIN MENU IDLE setting means if there is no command for the dome for a ANGUAG E ENGLISH period of time the dome will run the actions as defined lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt 1 Ze lt DOME SETTINGS gt lt CAMERA gt lt MOTION gt RESTART FACTORY DEFAULTS HELP 2 EXIT DOME SETTINGS lt IR LED gt UP lt IDLE gt lt ALARM gt lt PRIVACY MASK gt lt CLOCK gt lt PASSWORD gt lt DOME TITLE gt lt ADVANCED gt lt OTHERS gt BACK EXIT IDLE ACTION TIME 30SEC ACTION NONE BACK EXIT TIME Move the cursor to TIME and press IRIS OPEN to enter and move the joystick up and dome to select among 30 sec 1 min 5 min 10 min and 30 min And press IRIS OPEN to confirm ACTION Move the cursor to ACTION and
10. the item 4 Press Iris Open to enter the setup of each item 26 DISPLAY SETUP MAIN MENU Display setup allows the user to define the way to display the LANGUAG E ENGLISH dome titles on the monitor lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt s lt DOME SETTINGS gt The displayed titles are listed as follows lt CAMERA gt eee DOMETITLE Indicate dome FACTORY DEFAULTS PRESET Indicate the dwell time for preset title HELP MOTION Indicate the dwell time for auto function titles l EAL auto scan auto cruise pattern tour l ZONES Indicate the dwell time for zone titles P DISPLAY DATE TIME Display the current date and time DOME TITLE OFF PAN TILT Time to display PTZ info and zoom info PRESET 5 SEC ALARM Time to display alarm in out info MOTION 5 SEC display IR LED inf ZONES 5 SEC IR LED INFO Time to display info DATE TIME O N PROMPT Display prompt info a PAN TILT 5 SEC OTHERS l E vr aT Two options for the Dome Title and Date Time OFF and ON BACK Other setup selections include EXIT OFF Title will not be displayed when activated DISPLAY T ON Title will be continuously displayed when activated ALARM 5 SEC 2 SEC Title will be displayed for 2 seconds after activation IR LED INFO SSEC 5 SEC Title will be displayed for 5 seconds after activation PROMPT Sa 10 SEC Title will be displayed for 5 seconds after activation BACK EXIT Move the cursor by joystick to the one you need to set and press Iris
11. 1 100 high speed Pan 0 5 35 S Tilt 0 5 35 S Vair speed 360 S high speed 35 S Vari speed 360 continuous pan rotation 90 Auto Flip 220 0 1 8 auto scan tracks user defined left and right boundaries and scan speed 8 cruising tracks each cruising tracks has 32 preset positions user defined dwell time 4 groups each one with 10 Mins memory 500 programmable instructions The dome will rotate back to preset position after a period of vacant time Manual Auto Timing RS 485 Auto Compatible PELCO_P DELCO D Camera Module Auto Compatible SONY LG Samsung CNB HITACH etc Baud Rate 2400 4800 9600bps Operating Humidity O0 90 Operating Temp 35 60 C 4 Installation Guide 4 1 Preparations 1 Basic Requirements All the electric work must be finished under the latest electric amp fire prevention law and rules and any related law and rules Please check according to the packing list if every accessory is included And also make sure the installation is operated as required Please contact us for any help during the installation 2 Installation Space and Density Checkup Please make sure the space is big enough to install our dome And also ensure the density of the Max Distance Feet Meter ceilings or walls to hold total weight of the dome and its accessories 3 Cables Preparation Please choose the proper cable according to the transmission distance The min requirement o
12. Dome starts auto scan Default as Auto Scan 1 Dome runs auto cruise Default as Auto Cruise 1 Dome runs pattern Default as Pattern 1 39 CAMERA MAIN MENU LANGUAG E ENGLISH lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt Ze lt DOME SETTINGS gt lt CAMERA gt lt MOTION gt RESTART FACTORY DEFAULTS HELP EXIT DOME SETTINGS lt IR LED gt lt IDLE gt lt ALARM gt lt PRIVACY MASK gt lt CLOCK gt lt PASSWORD gt lt DOME TITLE gt 1 lt ADVANCED gt lt OTHERS gt BACK EXIT ADVANCED lt SOFT ADDRESS SET gt lt AUX gt lt SOFT LIMIT gt lt DOME SPEED gt lt POWER ON ACTION gt F lt CAMERA gt lt COMMUNICATION TEST gt EXIT BACK y CAMERA CAMERA AUTO BAUDRATE 2400 PARITY EVEN BACK EXIT The dome can automatically recognize the main camera modules in the market For the cameras it can not recognize the user can set up here CAMERA Move the cursor here and press IRIS OPEN to enter the setup mode Move the joystick up and down to select the camera types Press IRIS OPEN to confirm BAUDRATE Move the cursor here and press IRIS OPEN to enter the setup mode Move the joystick up and down to select the baud rate Press IRIS OPEN to confirm PARITY Move the cursor here and press IRIS OPEN to enter the setup mode Move the joystick up and down to select the parity mode Press IRIS OPEN to confirm 40 COMMUNICATIO
13. E ACTION Set the alarm action NONE default No action PRESET Dome goes to preset Default as Preset 1 SCAN Dome starts auto scan Default as Auto Scan 1 SEQ Dome runs auto cruise Default as Auto Cruise 1 PATTERN Dome runs pattern Default as Pattern 1 ALARM OUT Set the auxiliary to activate OFF Not alarm output will be activated OUT1 An alarm action will close AUX 1 output OUT2 An alarm action will activate AUX2 output RESET TIME Set up time for the alarm output such as an alarm buzzed when is triggered by the detector START STOP TIME Set up the time to start alarm and stop alarm ONLY under the AUTO mode under ALARM MODE 30 PRIVACY MASK MAIN MENU LANGUAG E ENGLISH lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt i lt DOME SETTINGS gt lt CAMERA gt lt MOTION gt RESTART FACTORY DEFAULTS AELP EXIT Ma A DOME SETTINGS lt IR LED gt lt IDLE gt lt ALARM gt Ze lt PRIVACY MASK gt lt CLOCK gt lt PASSWORD gt lt DOME TITLE gt lt ADVANCED gt lt OTHERS gt BACK EXIT PRIVACY MASK MASK NO 1 ENABLE ON SE T gt DELETE BACK EXIT Privacy mask allows the user to mask the privacy areas with black frame The user can set up 8 privacy masks at most MASK NO Move the cursor here and press IRIS OPEN to enter the setup of Mask Number of the privacy zone ENABLE To enable or disable this privacy mask function
14. ENE SET lt TRACKING SCENE SET gt DELETE RETURN DELAY 10SEC BACK EXIT Under the auto tracking mode the dome will auto track the moving objects entering the scene When the object is moving out of the scene the dome will return to a preset position as defined after the defined time SENSITIVITY The user can set up the auto tracking sensitivity under this menu When set as LOW the dome will do auto tracking when obvious object entering the screen When set as HIGH the dome will do auto tracking when small object moving into the screen Move the cursor there and press the IRIS OPEN to enter The options include LOW MID and HIGH TARGET To set up the size of the tracking object The options include Large MID and SMALL AUX If set ON here the object auto tracking will activate alarm aux output at the same time Press IRIS OPEN to enter to select ON or OFF ZOOM MATCH Under the auto tracking model if turn on the function of ZOOM MATCH the dome will do zooming in and out during auto tracking to keep the right proportion between the object and background Move the cursor there and press the IRIS OPEN to enter And move the joystick to select the optical zoom ENABLE Move the cursor here and press IRIS OPEN to enter to select ON or OFF to enable or disable this function TRACKING SCENE SET Here the user can set up the scene that the dome will get back to when finishing the action of auto tra
15. IR HIGH SPEED DOME CAMERA USER S MANUAL V3 0 Table of Contents POC AION TT 2 Fe CUT OS areen IE 3 Te ANC DUS a E 9 Installation Guide sss 10 DOme SeN Siirsin A EEEO 18 Operation IG ge Ee glen S aissein 22 1 Precaution 1 Please read this manual carefully before the installations and operations 2 Transportation Security No heavy stress violent vibration or water splash are allowed during transportation storage The unit should be transported in separated packing In shipments of distributor and delivery of maintenance any damages caused by integral packing are not covered by warranty 3 Installation Avoid heavy stress and violent vibration during installation Don t touch the dome cover directly by hand When connecting the power source please follow all electric safety standards and only use the power supply designated for this device Keep the video and control signal in a decent distance from high voltage devices and cable Don t apply power to dome before finishing the installation 4 Internal Environment Keep metal and inflammable material away from dome body to avoid fire short circuit and damage Please prevent all liquids material from entering the dome If this occurs please shut down the power and pull out the plug in Then please inform the technical personnel immediately 5 Electrical Safety The video image would be interfered when the dome is installed near Television radio transmitter volt
16. N lt DOME TITLE gt lt AZIMUTH ZERO gt BACK EXIT The user can set up TEMP MODE INTERNAL FAN PRESET FREEZE STOP TIME MENU OFF TIME and NORTH ZERO here under the menu of OTHERS TEMP MODE To set up the control mode of dome fans and heaters It includes three modes of AUTO FAN HIGH SPEED and FAN LOW SPEED PRESET FREEZE This feature freezes the scene on the monitor when going to a preset This allows smooth switching from one preset scene to another AUTO FLIP When the camera tilts downward and goes just beyond the vertical position the camera will rotate 180 degrees The user can press IRIS OPEN to enter and choose to turn on off this function STOP TIME To set up the time that dome will stops after receiving the last command Options include 5 15 30 60 Sec MENU OFF TIME To set up the time that OSD menu be off when no operations Options include 1 2 5 10 min NORTH ZERO To set up the due north of the dome pan 0 Move the cursor here and press IRIS OPEN to enter Move the joystick to control the dome to pan 0 and press IRIS OPEN to confirm 42 CAMERA MAIN MENU LANGUAG E ENGLISH lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt lt DOME SETTINGS gt ip lt CAMERA gt lt MOTION gt RESTART FACTORY DEFAULTS HELP EXIT FOCUS MODE AUTO DIGITAL ZOOM OFF BACKLIGHT OFF PICTURE FLIP OFF FREEZE OFF ZOOM SPEED NORMAL DAY NIGHT AUTO lt ADVAN CED gt BACK EXIT a
17. N TEST MAIN MENU LANGUAG E ENGLISH lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt 1 lt DOME SETTINGS gt lt CAMERA gt lt MOTION gt RESTART FACTORY DEFAULTS HELP EXIT DOME SETTINGS lt IR LED gt lt IDLE gt lt ALARM gt lt PRIVACY MASK gt lt CLOCK gt lt PASSWORD gt lt DOME TITLE gt IF lt ADVANCED gt lt OTHERS gt BACK EXIT Y ADVANCED lt SOFT ADDRESS SET gt lt AUX gt lt SOFT LIMIT gt lt DOME SPEED gt lt POWER ON ACTION gt lt CAMERA gt 1 lt COMMUNICATION TEST gt COMMUNICATION TEST KEYBOARD gt DOME 100 100 KEYBOARD lt DOME 100 100 DOME RECEIVE 100 KEYBOARD RECEIVE 100 BACK EXIT The dome can do self diagnosis for the communications between keyboard and speed dome The test needs to match with our software VK200 If the self testing is successfully finished via the software the system will show up the testing results as left diagram 41 OTHERS MAIN MENU LANGUAG E ENGLISH lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt Cr lt DOME SETTINGS gt lt CAMERA gt lt MOTION gt RESTART FACTORY DEFAULTS DOME SETTINGS lt IR LED gt lt IDLE gt lt ALARM gt lt PRIVACY MASK gt lt CLOCK gt lt PASSWORD gt lt ADVANCED gt 17 gt lt OTHERS gt BACK EXIT OTHERS TEMP MODE AUTO PRESET FREEZE OFF AUTO FLIP ON BROADCAST ON MENU STYLE IMAGE2 STOP TIME 30 SEC MENU OFF 5 MI
18. ORMATION gt lt DISPLAY SETUP gt lt DOME SETTINGS gt lt CAMERA gt i lt MOTION gt RESTART FACTORY DEFAULTS HELP EXIT a MOTION i gt lt PRESET gt lt SCAN gt lt SEQUENCE gt lt PATTERN gt lt ZONES gt lt TIMING ACTION gt lt MOTION DETECT gt lt AUTO TRACKING gt BACK EXIT a PRESET PRESET NO 001 TITLE PRESETO1 CALL lt SET gt DELETE SPEED HIGH BACK EXIT The dome supports 220 presets Please check the following steps to set up a preset 1 2 3 4 5 6 PRESET NO Move the cursor here and press IRIS OPEN to enter the setup of Preset Number Move the joystick to select a preset number 1 64 and 100 255 and press IRIS OPEN to confirm TITLE Move the cursor here and press IRIS OPEN to enter the setup of Preset Title Check the detailed above in DOME TITLE settings lt SET gt Move the cursor here and press IRIS OPEN to enter Move the dome to a defined position as preset point and press IRIS OPEN to save the preset position CALL Move the cursor here and press IRIS OPEN to call up the current preset DELETE Move the cursor here and press IRIS OPEN to delete the current preset SPEED Move the cursor here and press IRIS OPEN to set up the preset call up speed of LOW MID and HIGH 45 AUTO SCAN MAIN MENU LANGUAG E ENGLISH lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt lt DOME SETTINGS gt lt CAMERA gt iF lt M
19. OTION gt RESTART FACTORY DEFAULTS HELP EXIT MOTION lt PRESET gt ip lt SCAN gt lt SEQUENCE gt lt PATTERN gt lt ZONES gt lt TIMING ACTION gt lt MOTION DETECT gt lt AUTO TRACKING gt BACK EXIT en SCAN SCAN NO 1 TITLE SCAN 1 START lt LEFT LIMIT gt lt RIGHT LIMIT gt SCAN SPEED 20 BACK EXIT The dome supports 8 groups of auto scan Please check the following steps to set up a scan 1 2 3 4 5 6 SCAN NO Move the cursor here and press IRIS OPEN to enter the setup of SCAN Number Move the joystick to select a preset number 1 8 and press IRIS OPEN to confirm TITLE Move the cursor here and press IRIS OPEN to enter the setup of SCAN Title Check the detailed above in DOME TITLE settings lt LEFT LIMIT gt Move the cursor here and press IRIS OPEN to enter Move the dome to a defined position as left limit and press IRIS OPEN to save this left boundary lt RIGHT LIMIT gt Move the cursor here and press IRIS OPEN to enter Move the dome to a defined position as right limit and press IRIS OPEN to save this right boundary START Move the cursor here and press IRIS OPEN to start the current scan SCAN SPEED Move the cursor here and press IRIS OPEN to set up the scan speed ranging 1 30 46 AUTO CRUISE SEQUENCE MAIN MENU LANGUAG E ENGLISH lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt lt DOME SETTINGS gt lt CAMERA gt i
20. S wld Move the cursor to BACK EXIT and press IRIS OPEN to run the S se command of BACK or EXIT DOME SETTINGS lt IR LED gt lt IDLE gt lt ALARM gt lt PRIVACY MASK gt lt CLOCK gt lt PASSWORD gt lt DOME TITLE gt 1 lt ADVANCED gt lt OTHERS gt BACK EXIT ADVANCED lt SOFT ADDRESS SET gt lt AUX gt lt SOFT LIMIT gt Ze lt DOME SPEED gt lt POWER ON ACTION gt lt CAMERA gt lt COMMUNICATION TEST gt BACK EXIT f DOME SPEED SETTING DOME SPEED 180 BACK EXIT 38 POWER ON ACTION MAIN MENU The user can define the dome action when power on LANGUAG E ENGLISH lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt Move the cursor to POWER ON ACTION and press IRIS OPEN to i gt lt DOME SETTINGS gt enter the mode of setup lt CAMERA gt lt MOTION gt RESTART NONE FACTORY DEFAULTS PRESET HELP EXIT SCAN SEQ _ PATTERN DOME SETTINGS lt IR LED gt lt IDLE gt lt ALARM gt lt PRIVACY MASK gt lt CLOCK gt lt PASSWORD gt lt DOME TITLE gt Ze lt ADVANCED gt lt OTHERS gt BACK EXIT l ADVANCED lt SOFT ADDRESS SET gt lt AUX gt lt SOFT LIMIT gt lt DOME SPEED gt ZP lt POWER ON ACTION gt lt CAMERA gt lt COMMUNICATION TEST gt BACK EXIT Y POWER ON ACTION 1 POWER ON ACTION NONE BACK EXIT default No action Dome goes to preset Default as Preset 1
21. S gt ip lt CAMERA gt lt MOTION gt RESTART FACTORY DEFAULTS HELP EXIT A ae S CAMERA SETTING FOCUS MODE AUTO DIGITAL ZOOM OFF BACKLIGHT OFF PICTURE FLIP OFF FREEZE OFF ZOOM SPEED NORMAL DAY NIGHT AUTO i gt lt ADVAN CED gt BACK EXIT T nnn A N ADVANCED WB AUTO RED GAIN 208 BLUE GAIN 167 BRIGHT 01 EXPOSURE AUTO WIDE DYNAMIC OFF BACK EXIT The use can set up more detailed parameters of camera here under the menu of CAMERA ADVANCED WB To set up the white balance of the camera Options include AUTO MANUAL INDOOR and OUTDOOR The use can select different mode according the different locations RED GAIN Only can be adjusted whet WB set as manual BLUE GAIN Only can be adjusted whet WB set as manual BIRGHT To set up the brightness of the image Move the cursor here and press IRIS OPEN to enter Move the joystick to adjust and press IRIS OPEN to confirm EXPOSURE To set up the exposure mode of the camera Options include AUTO MANUAL SHUTTER PRIORITY IRIS PRIORITY and BRIGHT PRIORITY The use can select different mode according the different locations WIDE DYNAMIC Wide dynamic range WDR balances the brightest and darkest sections of a scene to produce a picture that is perfectly balanced in light and clarity Available settings are OFF LOW MID and HIGH The default setting is OFF 44 PRESET MAIN MENU LANGUAG E ENGLISH lt SYSTEM INF
22. SET Move the cursor here and press IRIS OPEN to enter the mode of setting the privacy mask Move the joystick Left Right Up Down on the screen to set up the privacy zone and press IRIS OPEN to confirm DELETE Move the cursor here and press IRIS OPEN to delete the current No of privacy mask zone 31 CLOCK MAIN MENU LANGUAG E ENGLISH lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt i gt lt DOME SETTINGS gt lt CAMERA gt lt MOTION gt RESTART FACTORY DEFAULTS HELP EXIT as IT TT at La DOME SETTINGS lt IR LED gt lt I IDLE gt lt ALARM gt lt PRIVACY MASK gt i lt CLOCK gt lt PASSWORD gt lt DOME TITLE gt lt ADVANCED gt lt OTHERS gt BACK EXIT a DATE TIME DATE 2009 01 01 TIME 12 00 SAVE CANCEL The dome can display the data and time And the user could enter this CLOCK menu to set up the DATE and TIME DATE Move the cursor here and press IRIS OPEN to enter Move the joystick left and right to choose the date position and move it up and dome to adjust the figures Press IRIS OPEN to confirm TIME Move the cursor here and press IRIS OPEN to enter Move the joystick left and right to choose the time position and move it up and dome to adjust the figures Press IRIS OPEN to confirm SAVE CANCEL Move the cursor to SAVE and press IRIS OPEN to save the settings Move the cursor to DELETE and press IRIS OPEN to cancel the settings 32
23. T FACTORY DEFAULTS HELP EXIT MOTION lt PRESET gt lt SCAN gt lt SEQUENCE gt lt PATTERN gt lt ZONES gt lt TIMING ACTION gt Ze lt MOTION DETECT gt lt AUTO TRACKING gt MOTION DETECT SCENE NO 1 lt EDIT SCENE gt IF lt EDIT AREA gt lt DELETE SCENE gt AUX ACTIVATE OFF CANCEL SEC 5 lt START gt BACK EXIT oy AREA EDIT AREA NO 1 lt AREA EDIT gt DELETE SEN SITIVITY MID BACK EXIT The user can set up 8 motion detection scenes each scene with 4 detecting areas under this menu The alarm output will be triggered when moving objects enter these detecting areas SCENE NO Move the cursor here and press IRIS OPEN to enter the setup of Scene Number Move the joystick to select a preset number 1 8 and press IRIS OPEN to confirm lt EDIT SCENE gt Move the cursor here and press IRIS OPEN to enter Move the dome to a user defined detecting scene Press IRIS OPEN to confirm lt EDIT AREA gt Move the cursor here and press IRIS OPEN to enter the menu of AREA EDIT a AREA NO Move the cursor here and press IRIS OPEN to enter the setup of AREA Number Move the joystick to select a preset number 1 4 and press IRIS OPEN to confirm b lt AREA EDIT gt Move the cursor here and press IRIS OPEN to enter the setup of AREA EDIT The screen will display frame with Serial No The user can move the frame to the top left conner of the wanted detectin
24. TEMP MODE AUTO PRESET FREEZE OFF AUTO FLIP ON BROADCAST ON MENU STYLE IMAGE2 STOP TIME 30 SEC MENU OFF 5 MIN lt DOME TITLE gt lt AZIMUTH ZERO gt BACK EXIT DOME TITLE SET INPUT lt CAPS gt ABCDEFGHIJ KLMNOPQRST UVWXYZ OK CANCEL The user can set up the dome title to define each camera Dome title support up to 12 characters Move the cursor according the left steps and select INPUT Press IRIS OPEN to enter 1 4 5 6 7 Move the joystick left and right to position and press IRIS OPEN to delete the character at lt Press IRIS CLOSE to exit the edit mode Move the cursor to lt CAP gt and press IRIS OPEN to enter Move the joystick up and down to select the input method such as English Cap English Chinese Figures and Symbols Mover the cursor to next line of lt CAP gt and press IRIS OPEN to enter the mode of character input The selected character will be shown in high brightness Move the joystick up down left right to choose the needed characters Press IRIS OPEN to move the selected character to the INPUT position aL After finishing the character inputs move the cursor to OK and press IRIS OPEN to confirm Also user can move the cursor to CANCEL to cancel the character input settings 34 SOFT ADDRESS SET 6 lt DOME SETTINGS MAIN MENU LANGUAG E ENGLISH lt SYSTEM INFORMATIONS lt DISPLAY SETUP gt CAMERA gt
25. age changer and audio amplifier 6 Camera Protection Avoid shooting very bright objects directly into the camera s CCD such As the sun or light fittings and avoid fixating the camera lens on bright static object for long time as it will cause Irreparable damage to the camera s CCD 7 Cleaning Method Please don t use abrasive and violent detergent to clean the dome Please choose dry fabric and neutral detergent And please use lens paper to clean the lens 8 Internal removing assembly repair and operations should be only performed by qualified service personnel 9 Please use our production under the following environmental standards Environmental Temperature 35 60 C Power Supply DC12V AA 2 Features 2 1 Main Features e Stepless speed changes auto zoom speed matching e Pan 0 01 360 S Tilt 0 01 120 S Preset 400 S high speed IR speed dome e Pan 0 5 20 Tilt 0 5 20 Preset 20 s for Vari speed IR dome e Auto object track with zoom in out and motion detection Auto Track Model e Timing actions for 7 days of programmable schedule e Built in Semi conductor heater amp digital temperature sensor e PWM cooling fan vari speed temperature control e Reserved network interface and space for network module e Pan Tilt accuracy 0 1 220preset positions e 8 cruising tracks each cruising track has 32 presets e 4 pattern tours 10 Mins memory 500 programmable instructions e Multi
26. atically return to preset position if there is no operation ina period of vacant time e Default Action When you start up the dome camera or do not send commands over a long time the dome camera will return to its default functions which include the home place auto pan auto cruise and pattern e Dome Address Setup The dome supports up to 256 addresses and the dome will only response to the instructions given to its own address Please check the dip switch on the bottom of the dome for address setup e Manual Object Tracking The use can move the joystick up down left or right to track the appearing object in the screen and use the joystick to zoom in and out with auto focus e Privacy Mask Protection Set black mask areas to protect the privacy zones The black privacy locations can be set and support up to 8 mask zones e Timing Running Function Users can set soeed dome operation task at total 8 timing areas during 7 days e Coordinates and Directions Display User can define the domes direction of due north which will help to show up the exact moving directions on screen And zone title is supported to display when the dome moves to the specified zone e Auto Tracking The dome will automatically fix and track the moving object according to the user s setup via OSD e Motion Detection The dome will detect the changes in the defined video zone and trigger alarm It supports to 8 video Locations each with 4 detection zone
27. bracket from the package as shown mark the installation hole positions on the ceiling referencing to the bottom of bracket 2 Drill the hole and install 4 pieces of M8 expansion bolt into the hole Drill Installation Holes 3 Take out the IR speed dome and put the cables through the sockets on the bottom of the pendant bracket Use M5 screws to fix the bracket and dome body i i Pendant mount bracket 220 485 4 Use screw nuts with washer to fix the bracket on the wall Notice Pendant bracket is not designed for outdoor installation If specially required please do make sure the waterproof installation of the dome Dome Setting Before the dome is installed please finish the setup of the communication protocol baud rate and dome address Set the DIP switch inside the dome body The relative DIP switch site and connecting wires are diagramed below for reference FUS VIDEO KS485 POWER ALARM IN ALAR OUT SW1 Dip switch for the dome address SW2 Dip switch for the dome protocol 1 Protocol Setup Our IR speed dome supports three protocols including Pelco P Pelco D and HS All of them supports baud rate of 9600bps 4800bps 2400bps Set the No 1 4 dip switch for the protocol configuration SW2 1 SW2 2 SW2 3 SW2 4 OFF OFF OFF OFF PELCOP ON OFF OFF OFF PELCOD QE ON OFF OFF e o o o l o d e 2 Baud Rate Setup Set the No 5 6 dip switch for the baud rate configu
28. cking Move the cursor here and press IRIS OPEN to enter Move the dome to the wanted scene and press IRIS OPEN to confirm DELETE Move the cursor here and press IRIS OPEN to delete the return scene RETURN DELAY To set up the time that dome will waiting to return to this scene RESTART 52 MAIN MENU The dome allows the user to reset its settings remotely under LANGUAG E ENGLISH this menu lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt Move the cursor here and press IRIS OPEN to enter lt DOME SETTINGS gt Select OK or CANCEL to continue the reset or cancel the lt CAMERA gt reset lt MOTION gt I RESTART FACTORY DEFAULTS HELP EXIT WARNING ARE YOU SURE OK CANCEL 53 FACTORY DEFAULTS MAIN MENU FACTORY DEFAULTS will allow the user to recover all the LANGUAG E ENGLISH setting to factory default setting lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt Move the cursor here and press IRIS OPEN to enter lt DOME SETTINGS gt Select OK or CANCEL to continue the reset or cancel the lt CAMERA gt reset lt MOTION gt RESTART Ge FACTORY DEFAULTS HELP EXIT WARNING ARE YOU SURE OK CANCEL 54
29. f coaxial BNC cable is listed as follows for reference RG59 U 750ft 229m RG6 U 1 000ft 305m RG11 U 1 500ft 457m 4 Setup Dip Switch for Dome Address Please turn to Part 5 for details 4 2 Installation Method The IR speed dome could be installed in wall mount and pedant mount 304 _ Power adapter bracket Dome housing Wiper Double lens Pendant mount Unit mm 11 4 3 Installation Dimensions Wall Mount pa 297 5 i 1 L G 1 S _ Power adapter bracket Dome housing Wiper Double lens 1 125 100 100 Pendant Mount 6 j i i Pendant mount bracket 485 105 4 4 Installation Procedures Notice The wall and ceiling must be thick enough to install the expansion bolts and can bear 4 times the weight of the dome camera itself Wall mount Installation Procedures 1 Take out the bracket from the package as shown mark the installation hole positions on the wall referencing to the bottom of bracket L 1 l Th 100 78 2 Drill the hole and install 4 pieces of M8 expansion bolt into the hole 3 Take out the IR speed dome and put the cables through the bracket Use M5 screws to fix the bracket and dome body 4 Use 4 pieces of M8 screw nuts with washer to fix the bracket on the wall Pendant mount Installation Procedures 1 Take out the
30. g area and press IRIS OPEN to confirm Then move the joystick to adjust the size of the detecting area and press IRIS OPEN to confirm c DELETE Move the cursor here and press IRIS OPEN to delete the current detecting area d SENSITIVITY Move the cursor here and press IRIS OPEN to enter Select among LOW MID and HIGH and press IRIS OPEN to confirm the sensitivity e DELETE SCENE Move the cursor here and press IRIS OPEN to delete the current scene f AUX ACTIVATE The dome can activate the alarm aux output when detecting the moving object Press IRIS OPEN to enter and select between ON and OFF to activate or deactivate this function g CANCEL SEC Here means when the alarm aux output is activated by the detecting function for how long it will last before the aux output will be closed The time ranging 1 60 Sec h START Move the cursor here and press IRIS OPEN to start the function of motion detection 51 AUTO TRACKING P hai Ur G MAIN MENL LANGUAG E ENGLISH SYSTEM INFORMATION gt lt DISPLAY SETUP gt lt DOME SETTINGS lt CAMERA lt MOTION gt RESTART FACTORY DEFAULTS HELP EXIT MOTION lt PRESET gt SCAN gt lt SEQUENCE gt PATTERN lt ZONES gt lt TIMING ACTION gt lt MOTION DETECT AUTO TRACKING gt BACK EXIT AUTO TRACKING SENSITIVITY MID TARGET MID ZOOM MATCH OFF AUX OFF ENABLE OFF lt TRACKING SCENE SE T gt BACK EXIT i TRACKING SC
31. gt lt MOTION gt RESTART FACTORY DEFAULTS HELP EXIT MOTION lt PRESET gt lt SCAN gt i lt SEQUENCE gt lt PATTERN gt lt ZONES gt lt TIMING ACTION gt lt MOTION DETECT gt lt AUTO TRACKING gt BACK EXIT SEQUENCE SEQ NO 1 TITLE SEQ 1 START i lt SEQUENCE SET gt DELETE BACK EXIT SEQUENCE PESET INTERVAL 002 03 001 03 NO gt gt 01 02 03 04 05 06 KZEDIT 01 003 03 INS BACK EXIT The dome supports 8 groups of auto cruise and each cruise supports 32 presets Please check the following steps to set up cruise 1 2 3 4 SEQ NO Move the cursor here and press IRIS OPEN to enter the setup of Sequence Number Move the joystick to select a preset number 1 8 and press IRIS OPEN to confirm TITLE Move the cursor here and press IRIS OPEN to enter the setup of Sequence Title Check the detailed above in DOME TITLE Settings lt SEQUENCE SET gt Move the cursor here and press IRIS OPEN to enter Move the cursor to EDIT and press IRIS OPEN enter edit mode of sequence Move the joystick left and right to select each item a When the lt gt is on the item NO move joystick up or down to select the Serial NO of the preset in a sequence There are up to 32 presets in each sequence b When the lt gt is on the item PRESET move the joystick up or down to select the preset NO that the user wants to add in the seque
32. is time segment Press IRIS OPEN to confirm lt SCAN gt lt SEQUENCE gt lt PATTERN gt MOTION To setup the motion that will be operated in this lt ZONES gt time segment The motion includes NONE PRESET 1 8 SCAN Ze lt TIMING ACTION gt lt MOTION DETECT gt lt AUTO TRACKING gt 1 4 SEQUENCE 1 4 and PATTERN 1 4 ON OFF Move the cursor here and press IRIS OPEN to enter to BACK enable or disable this function Press IRIS OPEN to confirm EXIT COPY The user could set up each 8 segment of 7 days separately or can copy the finished setting for one day to the current day Move the cursor there and press IRIS OPEN to TIMING ACTION copy the settings NO START STOP MOTION 1 00 00 00 00 NONE 2 00 00 00 00 NONE BACK Press IRIS OPEN to save and be back to last menu 3 00 00 00 00 NONE 4 00 00 00 00 NONE 5 00 00 00 00 NONE NOTE It is not allowed to set up the same time segment 6 00 00 00 00 NONE during one day And the time segment can not exceed 00 00 7 00 00 00 00 NONE During the timing action segment the defined action will be 8 00 00 00 00 NONE stopped if the user moves the dome If there is operation OFF MON COPY BACK during the defined time segment the action will re activated as long as it is in the defined timing action segment 50 MOTION DETECT MAIN MENU LANGUAG E ENGLISH lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt lt DOME SETTINGS gt lt CAMERA gt F lt MOTION gt RESTAR
33. lt MOTION gt RESTART 1 FACTORY DEFAULTS HELP EXIT DOME SETTINGS lt IR LED gt lt IDLE gt ALARM gt 2 lt PRIVACY MASK gt lt CLOCK gt lt PASSWORD gt Ze ADVANCED lt OTHERS BACK EXIT 3 ADVANCED gt lt SOFT SETTING gt AUS SOFT LIMIT gt lt DOME SPEED gt lt POWER ON ACTIONS CAMERA gt lt COMMUNICATION TEST gt BACK EXIT 4 lt SOFT SETTING gt lt SOFT ADDRESS SET gt SOFT PROTOCOL OFF SOFT BAUD RATE OFF BACK EXIT DOME SOFT ADDRESS SET SOFT ADDRESS 001 INPUT 000 255 INPUT 0123456789 SOFT ADDRESS OFF OK CANCEL The use can set up the SOFT ADDRESS SOFT PROTOCOL and SOFT BAUD RATE under this menu here to activate the soft address function And then the defined dome address by dip switch will be disabled Move the cursor to INPUT under DOME ID and press IRIS OPEN to enter the mode of setting dome ID Move the joystick to position the cursor beside 0 1234567 8 9 and press IRIS OPEN to enter And move the joystick again to select numbers of dome ID and press IRIS OPEN to confirm The number selected will be input on the upper line Move the cursor to INPUT the bottom menu and press IRIS OPEN to enter the mode of setting soft address Move the joystick to position the cursor beside 0 12 34567 89 and press IRIS OPEN to enter And move the joystick again to select numbers of dome soft address and press IRIS OPEN to confirm The number selected will be i
34. nce c When the lt gt is on the INTERVAL move the joystick up or down to select the interval time between each preset d When the lt gt is on the last item move the joystick up or down to select edition mode as INS insert ok and delete Press IRIS OPEN when selecting INS to insert the settings into the position of current Serial No Press IRIS OPEN when selecting OK to override the settings of Current Serial No Press IRIS OPEN when selecting delete to delete the settings of the Current Serial No Press IRIS OPEN to save all the setting and press IRIS CLOSE to exit DELETE START Move the cursor here and press IRIS OPEN to delete start the current sequence 47 PATTERN TOUR MAIN MENU LANGUAG E ENGLISH lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt lt DOME SETTINGS gt lt CAMERA gt i lt MOTION gt RESTART FACTORY DEFAULTS HELD EXIT a MOTION lt PRESET gt lt SCAN gt lt SEQUENCE gt i lt PATTERN gt lt ZONES gt lt TIMING ACTION gt lt MOTION DETECT gt lt AUTO TRACKING gt BACK EXIT PATTERN PATTERN NO 1 TITLE PATTERN 1 START lt SET gt DELETE BACK EXIT The dome supports 4 pattern tours and each pattern cover at most 10 Minutes of 500 commands Please check the following steps to set up a pattern 1 2 3 4 5 PATTERN NO Move the cursor here and press IRIS OPEN to enter the setup of Pa
35. nput on the upper line Enable or disable the soft address function Press IRIS CLOSE to exit last step Move the cursor to to SOFTADDRESS ON OFF Press iris open to enter Move the joystick up or down to select ON of OFF Press IRIS OPEN to confirm Press OK to save and confirm all the settings and press CANCEL to exit all the settings 35 AUX MAIN MENU LANGUAG E ENGLISH lt SYSTEM INFORMATION lt DISPLAY SETUP gt lt DOME SETTINGS gt lt CAMERA gt lt MOTION gt RESTART FACTORY DEFAULTS DOME SETTINGS lt R LED gt lt DLE gt lt ALARM gt lt PRIVACY MASK gt lt CLOCK lt PASSWORD TZ lt ADVANCED gt ZJ lt OTHERS BACK EXIT ADVANCED lt SOFT ADDRESS SET gt lt AUX gt lt SOFT LIMIT gt lt DOME SPEED gt lt POVWER ON ACTION gt lt CAMERA gt lt COMMUNICATION TEST BACK EXIT AUX AUX1 0FF AUA2 OFF BACK EXIT The user can set up the auxiliary output to trigger other devices from an alarm or a controller Move the cursor to AUX and press IRIS OPEN to enter to select ON or OFF to enable or disable this function 36 SOFT LIMIT E i ot MAIN MENU LANGUAG E ENGLISH lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt lt DOME SETTINGS gt lt CAMERA gt lt MOTION gt RESTART FACTORY DEFAULTS HELP EXIT DOME SETTINGS lt IR LED gt lt IDLE gt lt ALARM gt lt PRIVACY MASK gt lt CLOCK gt
36. ording to the focus in out which makes it much more practical for manual target tracking Only for the auto tracking IR soeed dome e Auto Flip When the camera tilts downward and goes just beyond the vertical position the camera will rotate 180 degrees e Preset Position Set up and Call Up In the Preset function the dome stores the current pan tilt angle zoom and other position parameters in its memory When necessary the dome recalls these parameters and adjusts the camera to a particular position The user can store recall and clear the presets easily and promptly by using the keyboard controller The dome can store up to 220 presets e Auto Scan Users can set up the left and right boundaries by control keyboard Then speed dome can scan between this boundary It supports up to 8 groups of scanning paths e Cruising Track The preset position can be programmed to be recalled in a set of sequences This sequence can be set to let the camera scan from one position to the next in a cycle at a set speed This feature is called the auto cruise The cruise sequence and dwell time of each preset can be set It supports up to 8 cruising tracks each cruising track with 32 presets e Pattern Tour Dome can memorize 600s running path or 500 programmable instructions When start pattern tour soeed dome will move automatically according recorded action path It supports 4 groups of pattern tours e Guard Location The dome will autom
37. oystick to select a zone number 1 8 and press IRIS OPEN to confirm TITLE Move the cursor here and press IRIS OPEN to enter the setup of Zone Title Check the detailed above in DOME TITLE settings lt LEFT LIMIT gt Move the cursor here and press IRIS OPEN to enter Move the dome to a defined position as left limit and press IRIS OPEN to save this left boundary lt RIGHT LIMIT gt Move the cursor here and press IRIS OPEN to enter Move the dome to a defined position as right limit and press IRIS OPEN to save this right boundary DELETE Move the cursor here and press IRIS OPEN to delete the current zone 49 TIMING ACTION TIMING ACTION allows the user to set up the actions of the dome in 7 days each day with 8 timing segments When fishing the setup the dome will do the actions according to the setup motion during the defined time segment MAIN MENU LANGUAG E ENGLISH lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt lt DOME SETTINGS gt lt CAMERA gt i lt MOTION gt RESTART FACTORY DEFAULTS NO Here shows the day within a week Move the cursor here and press IRIS OPEN to enter Move joystick up or down to select the Serial No 1 8 for the timing action Press IRIS HELP OPEN to confirm EXIT START To set up the start time for the defined motion within IT 1 this time segment Press IRIS OPEN to confirm MOTION STOP To set up the stop time for the defined motion within lt PRESET gt th
38. press IRIS OPEN to enter Move the joystick to select the actions including NONE PRESET SCAN SEQUENCE PATTERN Press IRIS OPEN to confirm 29 3 ALARM MAIN MENU LANGUAG E ENGLISH lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt i gt lt DOME SETTINGS gt lt CAMERA gt lt MOTION gt RESTART FACTORY DEFAULTS HELP EXIT DOME SETTINGS lt IR LED gt lt IDLE gt i lt ALARM gt lt PRIVACY MASK gt lt CLOCK gt lt PASSWORD gt lt DOME TITLE gt lt ADVANCED gt lt OTHERS gt BACK EXIT ALARM SETTING ALARM NO 1 CONTACT N O INPUT STATE OPEN ALARM MODE OFF ACTION NONE ALARM OUT OFF RESET TIME 10 SEC START TIME 00 00 STOP TIME 00 00 BACK EXIT The dome system has 2alarm inputs and 1 alarm output optional function When an alarm is received an input signal to the dome triggers the user defined action such as presets patterns etc and at meantime the alarm output signals is activated ALARM NO Move the cursor to the ALARM NO Press IRIS OPEN to enter and move the joystick up and down to select the alarm input no Channel 1 and Channel 2 INPUT STATE Set the alarm contact status There are two input states OPEN and CLOSE OPEN normally open CLOSE normally close ALARM MODE OFF Alarm function is deactivated ON Alarm function is activated AUTO AUTO Alarm function will be activated and deactivated between START TIME and STOP TIM
39. ration 3 Dome Address Setup PELCO P amp PELCO D Protocol of ofolo o ofo etot a i o o o o o 7 a Pee o o0 o fo 83o ojoj 1j o o o 0 9 2 o o a1 o oO OUT o sto of a1 of 1 of oO Oh fF LO a 0 1 o o o o 20 4 Cable Definition BNC Connector il Power Connector _ _ _ IM Red RS485A o Ce Yellow RS4858B BNC Connector Video Coaxial Cable 21 Power Connector DC12V Red RS485A Yellow RS485B Operation Instructions 1 Main Functions Fast Call Up Our IR Speed dome supports 220 preset positions You can activate some special functions by calling upon code number 65 99 ial 1 Start Auto Scan Call 99 Default to start auto scan of group No 1 2 Start Auto Cruise Call 98 Default to start auto cruise of group No 1 3 Start Pattern Tour Call 97 Default to start pattern tour of group No 1 A f sans arte Call 80 Call pp Call 99 Group No pp means Group No 1 8 5 Start Auto Cruise of Bal EE Group No pp Start Pattern Tour of Il 80 Call pp Call 97 1 Setting Open OSD Menu Set 95 Cor Call 95 eS 10 Recover Factory Default Call 82 COEF 2 System Self Testing The dome will do self testing after power up and system status will show Normal if system Is running normally If error happens testing result will be shown in O or X O means normal and X means error Please check the according meaning as follows 22 3
40. s e PTZ and Lens Control 1 Zoom Control Users can control zoom by keyboard to get near or far images 2 Focus Control The default setting is auto focus The camera will auto focus based on the center of the video display to get the clear image In some special occasions the user could do the manual focus to get the desired image effect 3 Auto Iris Control Auto Iris is aiming to detect the environmental lights condition and adjust the iris to get the stabilized brightness of the image 4 Auto Back Light Compensation In the highly bright background auto back light compensation is aiming to compensate the brightness of the dark object and adjust the background brightness to get a clear image 5 Auto Manual White Balance Auto Manual WB adjust depending on the environment light changes 6 Day and Night Switch Only for Day Nigh Camera Speed dome camera can auto switch according to the environmental illumination changes 7 OSD Setup Only for camera with menu Call upon preset No 95 to enter into OSD menu setup interface Press Focus to choose menu items and press Iris to set menu contents 3 Technical Specifications Power Supply Night IR Distance Manual Speed Preset Speed Pan Angle Tilt Angle Presets Positions Preset Accuracy Auto Scan Auto Cruising Pattern Tour Guard Location IR LED On Mode Data Communication Protocols DC12V 10 SOW 120 150 180meters Pan 0 01 180 Tilt 0 0
41. ttern Number Move the joystick to select a pattern number 14 and press IRIS OPEN to confirm TITLE Move the cursor here and press IRIS OPEN to enter the setup of Pattern Title Check the detailed above in DOME TITLE settings lt SET gt Move the cursor here and press IRIS OPEN to enter Move the dome up down left right make the zoom in out and press IRIS OPEN to save the pattern tour START Move the cursor here and press IRIS OPEN to start the current pattern tour DELETE Move the cursor here and press IRIS OPEN to delete the current pattern tour 48 ZONES MAIN MENU LANGUAG E ENGLISH lt SYSTEM INFORMATION gt lt DISPLAY SETUP gt lt DOME SETTINGS gt lt CAMERA gt i lt MOTION gt RESTART FACTORY DEFAULTS FELP EXIT lt PRESET gt lt SCAN gt lt SEQUENCE gt lt PATTERN gt ZP lt ZONES gt lt TIMING ACTION gt lt MOTION DETECT gt lt AUTO TRACKING gt BACK EXIT ZONES ZONE IS NOT SET ZONE NO 1 TITLE ZONE 1 lt LEFT LIMIT gt lt RIGHT LIMIT gt DELETE BACK EXIT C lt 3 ES MOTION The use can set up zone title when the camera moves to a defined location which will make it much easier for the user to identify the location The dome supports 8 zone titles Please check the following steps to set up a zone 1 2 3 4 5 ZONE NO Move the cursor here and press IRIS OPEN to enter the setup of Zone Number Move the j