Home
Battery Operated Acre Counter User Manual
Contents
1. LED will light and the LCD will show the pulse count The number displayed is the pulses per 400 feet If a password is set you will not be able to adjust the pulses per mile Loup Electronics e www loupelectronics com e 1 877 489 5687 2960 N 38 St Lincoln NE 68504 Page 4 5 8 14 ACRE COUNTER e a a FIELD TOTAL PULSES WIDTH P WORD BATT Lacres Width Press the STAR button until the WIDTH LED is lit The number displayed is the length of your implement in feet To adjust the width press the UP and DOWN buttons If a password has been entered you will not be able to adjust the width The length can be adjusted from 1 to 99 9 feet in tenths of a foot Loup Electronics e www loupelectronics com 1 877 489 5687 2960 N 38 St Lincoln NE 68504 Page 5 5 8 14 ACRE COUNTER e e E t a FIELD TOTAL PULSES WIDTH P WORD BATT L acres 4 Password The password function allows you to protect the total acre count pulses per 400 feet and width settings with a password This stops anyone from accidentally changing those settings When the acre counter is shipped the password is disabled You can modify the pulses per 400 feet and implement width at any time Press the STAR button until the PASS LED is lit The digits will display the word Ent or dis If the display shows dlS The password is disabled The total acre count pulses 400 ft width and passwor
2. ACRE COUNTER e e gt a FIELD TOTAL PULSES WIDTH P WORD BATT ACRES Battery Operated Acre Counter User Manual SOFTWARE VERSION 6 0 Loup Electronics e www loupelectronics com e 1 877 489 5687 2960 N 38 St Lincoln NE 68504 Page 1 5 8 14 The battery operated acre counter operates in one of two modes In sleep mode the display is blank and the counter is accumulating acres Sleep mode will be entered if a button is not pressed for 20 seconds In entry mode the display is on and the operator can enter values To get into entry mode press the STAR button If you continue to press the STAR button the acre counter will cycle through the functions that it can perform The LEDs above the display indicate which function is selected The available functions are ACRE COUNTER p amp 2 A FIELD TOTAL PULSES WIDTH P WORD BATT Lacres Field Acres Total Acres Pulses per 400 ft Width Password and Low Battery Field Acres Press the STAR button until the FIELD LED is lit The digits indicate the acres covered since the field acre counter was cleared To clear the field acre count press the UP and DOWN buttons for two seconds If a password has been entered you will not be able to clear the total acre count Field acres will count in tenths of an acre up to 9999 9 acres It will then count in whole acres to 99 999 Loup Electronics e www loupelectronics com 1 877 489 5687 2960 N 38 S
3. bled as instructed in the setup section of this manual Loup Electronics e www loupelectronics com 1 877 489 5687 2960 N 38 St Lincoln NE 68504 Page 8 5 8 14 Magnet Pick Up Mounting MAGNET TOP VIEW MAGNET PICK UP CHASSIS GND CONNECTION MOUNTING SHAET CABLE TIE SIDE VIEW MAGNET PICK UP SHAFT PICK UP Fj MOUNTING _ A MAGNET DISTANCE FROM MAGNET TO PICKUP Notes Pick up held in place with 6 32 hardware or equivalent not included Adhesive side of Magnet goes towards shaft Magnet can be taped in place if required Magnet Pick up distance must not exceed 0 125 1 8 The chassis ground connector must be secured under the mounting screw for ESD protection Loup Electronics e www loupelectronics com 1 877 489 5687 2960 N 38 St Lincoln NE 68504 Page 9 5 8 14 Loup Electronics e www loupelectronics com e 1 877 489 5687 2960 N 38 St Lincoln NE 68504 Page 10 5 8 14 Notes Loup Electronics e www loupelectronics com 1 877 489 5687 2960 N 38 St Lincoln NE 68504 Page 11 5 8 14
4. d settings can be adjusted using the UP and DOWN buttons The password can also be changed using the UP and DOWN buttons Loup Electronics e www loupelectronics com e 1 877 489 5687 2960 N 38 St Lincoln NE 68504 Page 6 5 8 14 If the display shows Ent You must enter your password using the UP and DOWN buttons When your password is displayed press the STAR button to test the password If the password is correct you will be able to change the acre counter settings The password will be viewable until the acre counter powers down When the acre counter is powered up again you will have to re enter the password to change settings If the password is not correct you will not be able to change the acre counter settings When the PASS function is selected again Ent will appear in the display Changing the password Select a new password using the UP and DOWN buttons Press the FUNC button until the word SEt appears in the display Release the FUNC button The number in the display is your new pass code Make sure you write it down Press and hold the FUNC button until the word dIS appears in the display If the password is forgotten it can be disabled by removing the batteries The password is intended for rental units It is recommended that a seal be affixed to the rear plate of the acre counter to determine if the settings have been tampered with Metric Units Area Accumulation The meter can be set
5. sition of the magnet actuator and sensor against the set up instructions in this manual 2 Verify that the magnet s have not come out of the actuator if it is a round plastic type snap on actuator 3 Place the Acre Meter display in Calibrate mode by pressing the star key until the P Word indictor is lit and then press the up down arrow keys until the display shows O and the LED is blinking Break the connection between the display and the sensor and short between pins A and B on the display harness connector You should see the display increment 1 with each contact of the connector terminals 4 f 3 works then wave a magnet in front of the sensor face with it re connected to the display and see if the display increments up If not put an ohm meter or continuity tester on the contacts of the sensor harness and place a magnet in front of the sensor face The sensor should show continuity or near O ohms resistance Note The ground wire is for static discharge protection and has no effect on the ability of the sensor to function properly under normal conditions Problem Can not change the width or pulse count settings or clear the field and total acres Check to see if a password needs to be entered by pressing the star key until the P Word indicator LED is lit If dIS is displayed password disabled no password is set If Ent is displayed a password must be entered to change the settings or the password must be disa
6. t Lincoln NE 68504 Page 2 5 8 14 ACRE COUNTER G e 2 E FIELD TOTAL PULSES WIDTH P WORD BATT L acres Total Acres Press the STAR button until the TOTAL LED is lit The digits indicate the acres covered since the total acre counter was cleared To clear the total acre count press and hold the UP and DOWN buttons for two seconds If a password has been entered you will not be able to clear the total acre count Total acres will count from 1 to 9999 9 acres It will then count in whole acres to 99 999 Loup Electronics e www loupelectronics com e 1 877 489 5687 2960 N 38 St Lincoln NE 68504 Page 3 5 8 14 ACRE COUNTER e e p t 4 FIELD TOTAL PULSES WIDTH P WORD BATT L ACRES J Pulses per 400 feet Press the FUNC button until the PULSES LED is lit The number in the display indicates how many pulses are generated for every 400 feet driven There are two methods to enter the pulses per 400 feet 1 If you know the number select it using the UP and DOWN buttons When you press the STAR button the Acre Counter will accept the number in the display as the new pulses per 400 feet 2 If you do not know the pulses per mile press and hold the UP and DOWN buttons until the O appears in the display The PULSES LED will blink The acre counter is now counting shaft rotations Enter the cab and drive 400 feet Press the FUNC button to wake up the acre counter The PULSES
7. to accumulate area in US or Metric Units by pressing and holding all 3 switch buttons for 5 seconds The units will toggle every 5 seconds or until the switches are released The current units can be checked by pressing all 3 buttons and releasing them before 5 seconds time passes US units are indicated by a scrolling U metric units by a scrolling E All defaults are reset when the units are changed The meter does not convert acres to hectares It resets the accumulation to 0 The password is reset to none when switching between modes Battery Replacement The battery operated acre counter uses 3 AA batteries The batteries should last between 5 and 10 years The acre counter will last much longer than that Eventually you will have to replace the batteries The BATT LED will light when the batteries require replacement Remove the acre counter from the implement and undo the 4 screws on the back of the case This will separate the housing from the rear plate Replace the batteries with 3 high quality AA alkaline batteries Loup Electronics e www loupelectronics com 1 877 489 5687 2960 N 38 St Lincoln NE 68504 Page 7 5 8 14 NOTE This unit is dust and splash resistant under no circumstances should this unit be submerged in any conductive corrosive or flammable liquid Acre meter trouble shooting Guide Problem Does not count pulses during calibration or does not count acres during operation 1 Check the po
Download Pdf Manuals
Related Search
Related Contents
取扱説明書 (操作編) Stereo Headphones ImageMaster VDS-CL - GE Healthcare Life Sciences User Manual - Key Prog Tools WT3000-I-Pro Undercounter Refrigerator Service Manual OVIPAR : une plate-forme d`initiation au parallélisme sous UNIX Manual do usuário Copyright © All rights reserved.
Failed to retrieve file