COMFORT P70 & P70 H49 INSERT USER MANUAL

image

Contents

1. Once the front hearth wall has been removed remove the two side cast iron parts undoing the screw highlighted in the picture below Then use the poker supplied to remove and scrape the soot deposited between the pipe unit and only then use a vacuum cleaner to fully remove the ash When cleaning is complete re position the extractable cast iron with the opposite movement used to remove it When the hearth wall has been positioned turn the lockbolt to put it back in its original position Extraflame ENGLISH ROUTINE MAINTENANCE In order to guarantee proper functioning and safety of the device the operations indicated below must be performed every season or more often when necessary DOOR ASH DRAWER AND BURN POT GASKETS The gaskets ensure the tightness of the stove and its consequent proper operation They must be checked periodically in the event they are worn or damaged they must be replaced immediately These operations must be carried out by a qualified technician CONNECTION TO THE FLUE Vacuum and clean the pipe that leads to the flue yearly or whenever necessary If there are horizontal sections the residues must be removed before they can obstruct flue passage ALWAYS FO
2. A Reference A Hot convection air 550 cm The heat accumulated A a inside the covering must be vented to prevent excessive lar overheating of the insert 27 I I I I gt Reference B Forced ventilation The tangential fan distributes the heat developed by the insert into the environment l I i A A A A Reference C iiri Room air inlet 550 I IE To allow air recirculation an air inlet point must be envisioned I l l which is preferably positioned in the lower part of the I structure in order to encourage convection The air must be 4 withdrawn from the machine s working environment gt THE FLUE OUTLET PIPE MUST ALWAYS MAINTAIN A MINIMUM DISTANCE OF 50 MM FROM INFLAMMABLE PARTS QExtraflame ENGLISH Make a hole at the base of the flue figure 1 for air circulation and to ensure the required combustion air for proper insert combustion If it is not possible to make hole at the centre of the base make two openings to the sides of the base equal to the 550cm overall lower inlet 2 x 275cm See figure 2 X 1 7 ase Air inlet Rt Le P70 P70H49 PI 1 I I I Base I P70 P70H49 Air inlet Air inlet 275cm 275cm figure 1 vr iw figure 2 dina AAN A A WL foren I I 5 Pd I Sy 2
3. PELLETA ssscsssssssessscssscesscessccssccsscsesesesscsnscsesssesssesssssessesesesssnecsesssesssessssessesesssccsnassesssesssescesecssesssssassnssssssescssonssecsssssssocssonses FRONT PELLET FEEDING OPTIONAL cssusss0ssonsnnsnnsnssnnsnsnnssnsnnsnnsnnsnssnsunsnnsnnsnnsnnsnnsnnsnnsnsnnsnsnnsnnsnnsnnsnssnnsnssnssnsnnssnsnne CONTROL PANEL YY DISPLAY ICONS KEY irreali aaa GENERAL MENU BASIC INSTRUCTIONS THE REMOTE DELAYED SWITCH OFF ENABLING TYPE AND REPLACEMENT OF BATTERIES COMMISSIONING 5 ADJUSTING TIME DAY MONTH AND YEAR ADJUSTING LANGUAGE OPERATION AND LOGIC ccccsssssssssscscsscessccssscesssescsesscsnsssssssssescssessesessocssoscsssssescssocsssassessssscssocsessssscssocssscssesessocssossssesones ADDITIONAL THERMOSTAT OPTIONAL 0 20s00s0usonssnsnnenssnssnssnssnsnnsnnsnnsnnenssnnsnsnnssnsnnsnnsnnsnssnssnsnnssnsnnsnnsnnsnnsnnsnssnssnsnnsnnsnnsen USER MENU Extraflame ENGLISH WARNINGS This instructions manual is an integral part of the product make sure that it always accompanies the appliance even if transferred to another owner or user or if transferred to another place If it is damaged or lost reguest another copy from the area technician This product is intended for the use for
4. Installation with internal flue flue Protection from Protection from rain and wind SEE rain and wind I Insulated flue Insulated fl nsulated flue 23 LSC psa Li 050 lt 2 Dd 23 Insulated 2 22 densation pd vee con nsatio proof T fitting Condensation proof with inspection gt T fitting with 23 plug inspection plug LI 23 u 23 LC IT 15 NOT RECOMMENDED TO INSTALL A 90 BEND AS THE FIRST INITIAL PART SINCE THE ASH WOULD BLOCK THE PASSAGE OF THE FUMES IN A SHORT TIME CAUSING PROBLEMS TO THE STOVE DRAUGHT SEE FIGURES BELOW Ash deposited in the 90 bend Ash deposited in the 90 bend QExtraflame ENGLISH VA EXAMPLES OF CORRECT CONNECTION TO THE CHIMNEY Protection from rain and wind Protection from rain and wind Steel plate 28 gt airtight TA y 7 O X 0 Max 3 mt aN 3 5 Insulated fitting with T fitting with inspection plug T fitting with inspection plug inspection plug
5. It is mandatory to use airtight pipes CHIMNEY In addition to the general requirements the chimneys for releasing combustion products into the atmosphere must operate under negative pressure operation under positive pressure is not allowed have a preferably circular internal section square or rectangular sections must have rounded corners with a radius of no less than 20 mm hydraulically equivalent sections may be used as long as the ratio between the longer side and the shorter side of the rectangle which circumscribes the section is in any case no greater than 1 5 designed for fumes be designed for fumes expulsion be predominantly vertical and have no narrowing along their entire length have more than two direction changes with a slope angle no greater than 45 be fitted with in the event of operating in damp conditions a device for reflux drainage condensation rainwater Ducted system Aducted system can be installed with one or more ducts operating only with negative pressure with respect to the environment The flexible hose compliant with UNI EN 1856 2 with T400 G characteristics meets the requirements CHIMNEY CAPS The chimney caps must meet the following requirements they must have a useful outlet section no less than double of that of the chimney ducted system on which it is installed they must be adapted in order to prevent the penet
6. Pia gt In order for the insert to work properly observe the measurements contained in the MINIMUM DIMENSIONS when building the chimney that must be made of non flammable material As well as the dimensions of the stove given in the technical features consider at least 50 mm of air at the back of the insert see figure 3 5 figure 3 protect from any over heating the Comfort P70 and P70h49 is supplied with a probe that analyses the temperature inside the structure and intervenes by reducing the functioning power gt THIS VENTILATION SYSTEM IS TOTALLY INDEPENDENT FROM THE AIR INTAKE FOR COMBUSTION Extraflame ENGLISH ASSEMBLY WITH SLIDING BASE Take the sliding base and position it in the pre existing flue Use chalk to mark the blocking holes of the base on the flue surface Drill 8 mm holes for the steel expansion inserts Make a hole measuring 60 mm in line with the air intake Remember the power socket on the rear of the insert so that the plug is accessible once installation is completed Fix the base using the clamping screws Create a flue exhaust and socket connection respecting the points described previously Take the insert tilt it so that the wheels fit into the relative rails make it run until the flue gas insert is completely inserted into the flue gas conveyor box PEDESTAL ASSEMBLY OPTIONAL Position the base in the desired point and use the
7. positioned so that they cannot be obstructed The air flow can also be obtained from a room adjacent to that of installation indirect aeration and ventilation as long as the flow takes place freely through permanent openings communicating with the outside The adjacent room cannot be used as a garage warehouse of combustible material or for any other activity with a fire hazard bathroom bedroom or common room of the building FUMES EXHAUST SYSTEM GENERAL REQUIREMENTS Each appliance must be connected to a suitable fumes exhaust system and ensure adequate dispersion of the combustion products into the atmosphere The combustion products must discharged above the roof Direct discharge from the wall or towards closed spaces is forbidden even with clear skies In particular it is forbidden to use flexible and extendible metal pipes The chimney should only receive the exhaust of the smoke duct connected to the appliance collective flues or conveying exhausts from hoods above cooking appliances of any kind or exhausts from other generators into the chimney itself or smoke duct are not allowed The smoke duct and the chimney must be connected with a continuity solution in order to prevent the chimney from resting on the appliance It is forbidden to have other air supply channels and pipes for plant engineering transit inside the fumes exhaust systems especially if over sized The components of the fumes exhaust system must be chosen
8. CONTROLS PROCEDURE Press key 6 and SET CLOCK will appear Press key 2 several times to reach SET USER Confirm using key 6 Press key 2 several times to reach STAND BY Using key 4 or 5 select at ON Press key 6 to confirm and key 1 to return to the previous menus up to the initial status The STAND BY function is active 060 6 KEYS LOCKED The menu allows to lock the display keys like with mobile phones With the function engaged every time a key is pressed KEYS LOCKED will appear CONTROLS PROCEDURE Press key 6 and SET CLOCK will appear Press key 2 several times until USER is displayed Press key 6 DISPLAY will appear Press key 2 until KEYS LOCKED appears Use keys 4 5 to select enable disable Press key 6 to confirm and key 1 to return to the previous menus up to the initial status 0 0 ONCE THE FUNCTION IS ACTIVATED USE KEYS 1 AND 5 AT THE SAME TIME TO LOCK OR UNLOCK THE KEYBOARD QExtraflame ENGLISH V2 AIR NOT USED The menu allows to adjust the speed of the ducted fan in percentage CONTROLS PROCEDURE Press key 6 and SET CLOCK will appear Press key 2 several times until USER is displayed Press key 6 DISPLAY will appear Press key 2 until V2 AIR appears i 2 Use keys 4 5 to increase 4 or decrease 5 Press key 6 to confirm and key 1 to return to the previous menus up to the initial status 0 9199 RESET Allo
9. ave 2 z 2 RE 2 Lj OK Kil QExtraflame ENGLISH counter slope sections are not allowed thesmoke ducts must have along their entire length a diameter that is no less than that of the attachment of the appliance exhaust pipe any section changes are allowed only on the inlet to the chimney they must be installed so as to limit the formation of condensation and prevent their release from the joints they must be positioned at a distance no less than that indicated in the product specifications from combustible materials the smoke channel duct must allow to collect the soot and to be cleaned using a swab and inspected after being disassembled or through inspection openings when not accessible from inside the appliance ADDITIONAL REQUIREMENTS FOR APPLIANCES FITTED WITH AN ELECTRIC FAN FOR FUMES EXPULSION For the heat generator appliances equipped with electric fan for expelling fumes the instructions below must be followed The horizontal sections must have a minimum upward slope of 3 The length of the horizontal section must be minimal and in any case no longer than 3 metres The number of direction changes including the one due to the use of the T element must not be more than 4 VA EXAMPLES OF CORRECT CONNECTION TO THE CHIMNEY Installation with internal external
10. 9 INCREASE 10 ESC KEY 11 BACK 12 CONFIRMATION KEY 13 FORWARD 14 ENABLE FUNCTION F1 15 DECREASE 16 STOVE STATUS Pressing this key will display the general status of the stove Important note the numbers shown on the remote control are purely indicative and are not present on the remote control supplied with the product TYPE AND REPLACEMENT OF BATTERIES The batteries are housed in the lower part of the remote control To replace them remove the battery holder as indicated in the figure at the back of the remote control remove or insert the battery according to the symbol on the remote control and on the battery itself For operation 1 CR2025 lithium buffer battery is required The batteries used contain metals harmful for the environment They must therefore be disposed of separately in appropriate containers gt If the remote control is off because it has no batteries the stove can be controlled from the control panel on top of it While replacing the battery pay attention to the polarity by observing the symbol on the inside compartment of the remote control Extraflame ENGLISH COMMISSIONING SETT NGS Once the power cable at the back of the stove has been connected move the switch also located on the back to 1 The switch at the back of the stove powers the stove board The stove remains off and a first screen appears on the panel reading
11. FRAME ASSEMBLY FOR P70 AND FOR P70H49 The side frames are fitted using 2 screws per side as shown in figure 3 THE INSERT MUST OVERLAP THE MARBLE COVERING SURFACE BY AT LEAST 1 CM MUST BE PROTECTED WITH NON INFLAMMABLE MATERIAL FRAME ASSEMBLY IS IMPORTANT AS IT ALLOWS CORRECT RECIRCULATION OF THE AIR AND CONSEQUENTLY OPTIMAL PRODUCT OPERATION A N B ANY WOODEN BEAMS LOCATED ABOVE THE INSERT figure 3 QExtraflame ENGLISH INSERT LOCKING AND RELEASING SAFETY DEVICE Open the door and turn using the poker supplied insert the lockbolt in the corner at the bottom on the left and turn anticlockwise to open release or clockwise to close lock 1 NA A N NA NN UNS N x N N X_NT A 5 NN NA 5 AN N 3 N N N x N N N N N N 222 OPEN RELEASED CLOSED LOCKED To understand whether the insert is attached to the base properly connect the plug to the socket and make sure it works with the supplied remote control REMOVING THE INSERT AND LOADING PELLETS The extraction of the insert allows pellets to be loaded inside the feed box and to perform routine maintenance cleaning the ash pipe at the end of the year or special maintenance replacement of mechanical parts if the product should
12. OFF ADJUSTINGTIME DAY MONTH AND YEAR Set clock allows to adjust the time and date SET CLOCK CONTRO ele DURE DAY MON TUE WED SUN Press key 6 and SET CLOCK will appear ne E MINUTES 00 59 Use keys 4 5 to select the day DATE 1 31 Proceed by pressing key 2 MONTH 1 12 With the same procedure use keys 4 or 5 to set and key YEAR 00 99 2 to move forward to adjust the hours minutes day month and year Press key 6 to confirm and key 1 to return to the previous menus up to the initial status ADJUSTING LANGUAGE It is possible to select the preferred language to display the various messages SET LANGUAGE CONTROLS PROCEDURE ITALIAN Press key 6 and SET CLOCK will appear ER Press key 2 until SET LANGUAGE appears Confirm using key 6 PENG Select the language using key 4 or 5 SPANISH Press key 6 to confirm and key 1 to return to the previous menus up to the initial status NO IGNITION 20278 FIRST IGNITION COULD EVEN FAIL AS THE AUGER IS EMPTY AND IS NOT ALWAYS ABLE TO LOAD THE BURN POT WITH THE REQUIRED AMOUNT OF PELLETS ON TIME TO REGULARLY START THE FLAME IF THE PROBLEM OCCURS AFTER ONLY A FEW MONTHS WORKING CHECK THAT ROUTINE CLEANING STATED IN THE STOVE BOOKLET HAS BEEN CARRIED OUT CORRECTLY CLEAN CHECK UP 1 2 BURN POT BOTTOM IN THE EVENT THE ALL NO FLUSSO ALL CLEAN CHECK UP ALARM IS TRIGGER
13. blocked Electronic pressure switch in the event of inadequate depression it sends the machine in alarm conditions F 2 5 A 250V fuse stoves protects the machine from violent current surges 85 C calibrated mechanical bulb with manual rearm intervenes by blocking fuel feed whenever the pellet tank t reaches the limit of 85 C Rearm must be performed by qualified staff and or the manufacturer s technical after sales assistance Pellet tank temperature control probe if the tank over heats the machine automatically modulates to return to 2 normal temperature values in the applicable models Mechanical air pressure switch blocks the pellet in the event of insufficient depression in the relevant models REFERENCE STANDARDS The installation must be in compliance with UNI 10683 2012 heat generators fed with wood and other solid fuels installation The chimneys must be in compliance with UNI EN 13063 1 and UNI EN 13063 2 UNI EN 1457 UNI EN 1806 in the event of non metallic chimneys EN 13384 1 13384 chimneys Thermal and fluid dynamic calculation methods UNI EN 1443 2005 chimneys general requirements UNI EN 1457 2012 chimneys clay ceramic flue liners UNI TS 11278 2008 Metal chimneys flue liners flue ducts UNI 7129 point 4 3 3 Fire Brigade provisions local rules and regulations NATIONAL REGIONAL PROVINCIAL AND TOWN COUNCIL REGULATIONS One must a
14. in relation to the type of appliance to be installed in compliance with inthe event of metal chimneys UNI TS 11278 with particular attention to what is stated in the specification inthe event of non metallic chimneys UNI EN 13063 1 and UNI EN 13063 2 UNI EN 1457 UNI EN 1806 Considering especially temperature class pressure class fumes seal at least equal to the seal required for the appliance moisture resistance resistance to condensation class or level of corrosion and specification of the materials constituting the inner wall in contact with the fumes soot fire resistance class minimum distance from combustible materials The installer of the fumes exhaust system once the installation is complete and the relevant checks and inspections have been made must fix the chimney plaque supplied by the manufacturer with the product in a visible manner near the fireplace and which must be completed with the following information 99 Extraflame ENGLISH nominal diameter distancefrom combustible materials indicated in millimetres followed by the arrow and flame symbol installer data and date of installation Every time one must cross combustible materials the following indications must be complied with a 7 1 Rp a AN 1 5 DESCRIPTION QUOTAIMM b Minimum di
15. technical compartment even in new buildings Sealed installation Installation of an appliance with sealed operation so that all the air required for combustion is taken from outside Maintenance Set of procedures required to ensure and maintain safety and functionality over time and maintain the efficiency of the system within the prescribed parameters Chimney system Chimney installed using a combination of compatible components manufactured or specified by a sole manufacturer whose product liability covers the entire chimney Fumes exhaust system Flue gas exhaust system independent from the appliance made up of a smoke duct chimney or individual flue and chimney cap Radiation area Area immediately in front of the hearth in which the radiant heat caused by combustion is diffused Reflux area Area beyond the extrados of the roof in which overpressure or depressions occur which may affect the proper discharge of the combustion products Extraflame ENGLISH FUNCTIONAL OPERATIONS DIAGRAM State of the art installation and proper system operation include a series of activities 1 Preliminary activities verification of the suitability of the installation site verification of the suitability of the fumes exhaust system verification of the suitability of the outside air inlets 2 Installation implementation of ventilation and connection to the outer air inlets implementation and connection to the fume
16. the contact of the external additional thermostat d Contact closed the contact of the external additional Flashing with closed the contact of the external additional thermostat thermostat is closed and the STBY contact is closed and the STBY function is active N function is disabled 2 Contact open the contact of the external additional Flashing with open the contact of the external additional thermostat thermostat is open and the STBY contact 15 open and the STBY function is active function is disabled Extraflame ENGLISH GENERAL MENU D 1 GO BACK EXIT 2 3 PARAMETER SCROLLING NEXT 2 PREVIOUS 3 0 WE MODIFY SETTINGS DATA INCREASE 4 DECREASE 5 6 CONFIRM ACCESS MENU SET CLOCK O Eo CHRONO SETTING H6 ENABLE CHRONO DAY LANGUAGE H6 gt ITEN FR DEES gt wmvs START PRG1 HOURS USER 6 DISPLAY STOP PRG1 MINUTES PELLETS MONDAY PRG1 IN ON OFF V1 AIR SUNDAY PRG1 TANGENTIAL ON OFF 7 TECHNIC SET RESERVED TO THE QUALIFIED STAND BY SET PRG1 TECHNICIAN WE REPEAT THE SAME STEPS FOR KEYS LOCKED THE OTHER 3 TIME SLOTS V2 AIR RESET NOT USED BASIC INSTRUCTIONS The following recommendations mus
17. ACTED QExtraflame ENGLISH CONTROL PANEL OPERATION POWER DISPLAY OF VARIOUS TEMPERATURE TO ACCESS ADJUSTMENT TEXT MESSAGES SETTING THE MENU BUTTON ON OFF DISPLAY ICONS KEY Indicates the receipt of the radio signal ZA On during radio communication Off no radio communication Fixed on serial input disabled It indicates weekly programming functioning Indicator on weekly programming active Indicator off weekly programming disabled Indicates the stove modulation On the stove is working at the set power Flashing the power at which the stove is working is different to the power set the stove is modulating for various reasons It indicates fumes motor operation Sez Off fumes motor disabled On fumes motor active Flashing breakdown DON On working Flashing motor at minimum Indicates the presence of an alarm Triangle On 1 flashing key Indicates the presence of an alarm 211 indicates pellet feed motor operation Off pellet feed motor disabled lt On pellet feed motor active It indicates tangential fan operation where applicable CZ Off not working ae fo Indicates the compensation function Indicates the room temperature status Off the function is disabled Off the T read by the probe is above the set temperature On the function is active 2 On the T read by the probe is below the set temperature Indicates
18. ANTY IS NOT CONSIDERED VALID IN THE FOLLOWING CASES The warranty conditions described above have not been respected Installation has not been performed with respect to the Standards in force regarding the provisions described in the manual book provided with the appliance Negligence of the customer due to lack of or incorrect maintenance of the product Presence of electric and or hydraulic plants that do not comply with the standards in force Damages deriving from atmospheric chemical electro chemical agents improper use of the product modifications and tampering with the product inefficacy and or unsuitability of the flue and or other causes not deriving from the manufacture of the product Combustion of materials not compliant with the types and quantities indicated in the manual book supplied All damages caused by transport It is therefore recommended to carefully check the goods on receipt immediately informing the dealer of any damage making a note on the transport document and on the carrier s copy EXTRAFLAME S p A is not liable for any damage that can directly or indirectly affect persons objects and pets as a consequence of failure to comply with the prescriptions indicated in this manual book ALL PARTICULARS SUBJECT TO NORMAL WEAR ARE NOT COVERED BY WARRANTY This category includes The gaskets all ceramic or toughened glass coverings and cast iron or lronker grates the painted chrome or gold plated
19. CTS NON INFLAMMABLE OBJECTS A 200 mm 100mm B 1500mm 750 mm 200 mm 100 mm figure 1 Inspection figure 2 9 Air inlet S floor protection In any case the temperature of the adjacent combustible materials must not reach a temperature equal to or greater than the room temperature increased by 65 C The minimum volume of the premises in which to install the appliance must be greater than 15 m QExtraflame ENGLISH VENTILATION AND AERATION OF THE INSTALLATION PREMISES Ventilation is deemed sufficient when the room is equipped with air inlets according to the table Air inlet See figure 2 Percentage of the gt net opening section with Minimum net opening value of Appliance categories Referen ndar Joi Sference standard respect to the appliance fumes the ventilation duct outlet section Pellet stoves UNI EN 14785 80 cm In any case ventilation is deemed sufficient when the pressure difference between the external and internal environment is equal to or less than 4 Pa In the presence of type B gas appliances with intermittent operation not intended for heating they must have their own aeration and or ventilation opening The air inlets must meet the following requirements they must be protected with grids metal mesh etc but without reducing the net useful section they must be made so as to make the maintenance operations possible
20. ED MAKE SURE THAT THE BOTTOM OF THE BURN POT IS FREE OF RESIDUES OR SCALES THE HOLES AT THE BOTTOM MUST BE COMPLETELY FREE TO GUARANTEE CORRECT COMBUSTION ONE CAN USE THE FUNCTION PELLET FEED ADJUSTMENT TO ADJUST COMBUSTION ACCORDING TO THE DESCRIBED REQUIREMENTS IF THE ALARM PERSISTS AND THE ABOVE LISTED CONDITIONS HAVE BEEN CHECKED CONTACT THE QUALIFIED AFTER SALES ASSISTANCE CENTRE QExtraflame ENGLISH OPERATION AND LOGIC OFF 22 5 C 14 10 IGNITION Once the points listed previously have been checked press key 1 for three seconds to ignite the stove 15 minutes are given for the ignition stage after ignition and once the control temperature has been reached the stove interrupts the ignition phase and switches to the START UP mode STARTING During the start up stage the stove stabilises combustion increasing it gradually to then start ventilation and switch to the WORK mode WORK During the work stage the stove reaches the set power and works to reach the set room temperature See following item THERMOSTAT SETTING ADJUSTMENT The room temperature setting can be set using buttons 4 and 5 from Low 07 to 40 C Hot LOW HOT If the temperature setting is on Low set below the 7 C threshold the stove will always function at minimum If the setting is on Hot set above the 40 C threshold the stove will not modulate always functioning a
21. LLOW THE INSTRUCTIONS IN MAXIMUM SAFETY CONDITIONS e WITHTHE STOVE FULLY COOLED DOWN SWITCHED OFF AND DISCONNECTED FROM THE MAINS ELECTRICITY gt e FAILURE TO CLEAN JEOPARDISES SAFETY e FORPROPER OPERATION THE STOVE MUST UNDERGO ROUTINE MAINTENANCE BY A QUALIFIED TECHNICIAN AT LEAST ONCE A YEAR e IF THE POWER SUPPLY CABLE IS DAMAGED IT MUST BE REPLACED BY THE AFTER SALES SERVICE OR BY A SIMILARLY QUALIFIED PERSON SO AS TO AVOID ALL RISKS Fumes motor disassembly and cleaning and fumes pipe new silicone in required points Inspection of gaskets and door replace them and apply silicone where required Combustion chamber total cleaning of the entire chamber and ignition plug holder tube cleaning Tank complete emptying V and cleaning Room air fan disassembly and removal of dust and any pellet debris 5 Air intake pipe inspection and of flow sensor Mm cleaning Extraflame ENGLISH DISPLAYS DISPLAY REASON OFF Stove off START The start phase is in progress PELLET FEEDING Pellet feeding during the ignition phase is in progress IGNITION The ignition phase is in progress START UP T
22. PLAY This menu allows to adjust the brightness of the display By default set on OFF the display and keys backlight will switch off after a preset delay The back light will go on as soon as a key is pressed or if an alarm should be triggered in the machine By setting between 10 and 31 adjust the lighting intensity of the display 10 minimum brightness 31 maximum brightness and the backlight always stays active CONTROLS PROCEDURE Press key 6 and SET CLOCK will appear Press key 2 several times until USER is displayed Press key 6 DISPLAY will appear Use keys 4 5 to select the brightness of the display OFF Press key 6 to confirm and key 1 to return to the previous menus z 225 C 14 10 up to the initial status 225 C 14 10 0 0 PELLET FEED ADJUSTMENT The following menu allows to adjust the percentage of pellet feed If the stove has functioning problems owing to the quantity of pellets adjust pellet feeding directly from the control board The problems correlated to the amount of fuel can be divided into 2 categories QExtraflame ENGLISH NO FUEL the stove can never develop a suitable flame tending to remain very low even at high powers at minimum power the stove tends to almost switch off taking the stove into NO PELLETS alarm condition when the stove displays the NO PELLETS alarm there may be non burned pellets inside the burn pot EXCESS FUEL the stove develop
23. T SYSTEM PRODUCT REQUIREMENTS Temperature class In the event of a pellet appliance temperature classes below T200 are not allowed Soot fire resistance class The fumes exhaust system interlocked with appliances supplied by solid fuels require soot fire resistance and the specification must be indicated by the letter G followed by the distance from combustible materials in millimeters XX in compliance with UNI EN 1443 In the event of pellet appliances the fumes exhaust systems must be airtight if double designation elements are used G and O with or without seal elastomer for connecting the appliance to the chimney one must comply with the minimum distance XX in millimeters indicated for designation G in the event of fire due to soot one must ensure the restoration of the initial conditions by replacing the gaskets and damaged items and cleaning those remaining in use Ignition tests Operation of the appliance must be verified with an ignition test i e for mechanical feed appliances one must complete the ignition test verify proper operation for at least the next 15 minutes and adjust the switch off For appliances installed in a hot water heating system closed fireplaces thermo stoves testing must also extend to the entire hydraulic circuit QExtraflame ENGLISH Coverings and finishings The coverings and finishings must only be applied after having verified the proper operation of the appliance according to the
24. XTRAFLAME S p A does not grant any compensation for direct or indirect damage caused or depending on the product LAW COURT The Vicenza Law Court is elected as the competent court for any disputes QEXtraflame Extraflame uExtraflame Riscaldamento a Pellet EXTRAFLAME S p A Via Dell Artigianato 12 36030 MONTECCHIO PRECALCINO VI ITALY FN 39 0445 865911 E 39 0445 865912 24 info extraflame it A www lanordica extraflame com Extraflame reserves the right to vary the features and data shown in this booklet at any time and without prior notice in order to improve its products This manual cannot be considered as a contract for third parties This document is available at www extraflame it support 004275999 Manuale Utente Inserti P70 P70h49 002
25. ame ENGLISH ALARMS DISPLAY EXPLANATION SOLUTION AB The fixed triangle on the display and key 1 flashing slowly indicate the presence of an alarm On and flashing indicates the presence of an alarm The alarm can be reset by pressing button 3 for 3 seconds only if the fumes motor has stopped and if 15 minutes have elapsed from when the alarm was displayed ASPIRAT FAULTY Fault correlated to the flue gas exhaust motor The restoration operations must be carried out by an authorised technician The restoration operations must be carried out by an authorised FUMES PROBE Fault correlated to the fumes probe chnician Check pellet flow see Pellet feed adjustment ALARM Thefuegastemperanurenas Shchhatthe machine dn he fumes passage FUMES OVERHEATING exceeded 310 C Other restoration operations must be carried out by an authorised technician CLEAN CHECK UP 1 2 1 IN START UP STAGE 2 IN OPERATING STAGE The combustion chamber or burn pot bottom are dirty The door is not closed correctly The ash drawer is not closed correctly The depression sensor is faulty The flue exhaust pipe is blocked Incorrect installation Make sure the holes at the burn pot bottom are completely free Check cleanliness of the fumes pipe and the combustion chamber Check hermetic door closure Check hermetic closure of the ash drawer Other restoration operations must be c
26. an be adjusted using the remote control The table below provides a detailed description of the various functions Pressing the key for three seconds the stove will switch on or off Pressing the key will increase the operating power Pressing the key will decrease the operating power The temperature setting can be increased by pressing this key The set temperature can be decreased by pressing this key Pressing the key once will enable or disable the chrono The delayed switch off can be set by pressing this key For example if the stove is set to switch off in an hour it shall switch off automatically once the set time elapses displaying the countdown every minute for delayed automatic shutdown This key allows to access the user and technical menu the technical menu is reserved for assistance The temperature setting can be increased by pressing this key The key allows the user to exit any program or display and returns to the main menu without saving the data The key returns to the display of the various menus This key confirms the adjustments made during the user menu programming phase The key allows to go forward in the various menus Pre set key for future applications The key decreases the value to be set 1 ON OFF 2 POWERINCREASE 3 POWER DECREASE 4 T INCREASE 5 T DECREASE 6 ENABLE DISABLE CHRONO 7 DELAYED SWITCH OFF ENABLING 8 MENU
27. arried out by an authorised technician The mechanical depression sensor DEPR ALARM i Contact after sales centre has tripped The pellet feed box is empty Check for the presence of pellets in the feed box MN Adjust pellet flow see Pellet feed adjustment NO Pellettred c lihrati n inadeguate Check the procedures described in the Ignition chapter IGNITION Incorrect installation p g pter Other restoration operations must be carried out by an authorised technician BLACK OUT NO IGN No current during the ignition phase Set the stove on OFF using key 1 and repeat the procedure described in the Ignition chapter Other restoration operations must be carried out by an authorised technician NO PELLETS In the work phase the t of the flue gases has dropped below default parameters Check for the presence of pellets in the feed box Regulate the pellet flow Other restoration operations must be carried out by an authorised technician COOLING STAND BY Attempt to release the alarm with stove still in cooling mode Every time the stove displays one of the alarms listed above it will switch off automatically The stove will block any alarm unlock attempt during this phase showing the alarm itself and STAND BY alternately on the display The alarm can be reset by pressing button 1 for 3 seconds only if the fumes motor has stopped and if 15 minutes have elapsed from when the alarm was displ
28. ayed of pellet motor ge ni Component disconnected or faulty Contact after sales assistance AUGER CONTROL Anomalous functioning liana ALARM of pellet feeding Abnormal functioning AUGER BLOCK Contact after sales assistance Extraflame ENGLISH WARRANTY CONDITIONS EXTRAFLAME S p A with offices in via dell Artigianato 12 Montecchio Precalcino VI guarantees this product for 2 two YEARS from the date of purchase for manufacture and material faults The warranty becomes void in the event the defect is not reported to the dealer within two months from the date it was detected The responsibility of EXTRAFLAME S p A is limited to the supply of the appliance which must be installed as per regulations and following the instructions contained in the relevant manuals and booklets provided with the purchased product and in compliance with the laws in force Installation must be performed by qualified staff under the responsibility of the person entrusting him who will assume complete responsibility for the definitive installation and consequent good functioning of the product installed EXTRAFLAME S p A cannot be held responsible in the event that these precautions are not be respected WARNING It is essential to carry out the functioning inspection of the product before its completion with the relative masonry finishings counterhood external coating pilasters wall painting etc EXTRAFLAME S p A does not assu
29. been reset to zero DO NOT ALLOW THE BAG OF PELLETS TO COME INTO CONTACT WITH THE BOILING HOT STOVE DURING THE FILLING PHASE IN THE EVENT OF CONTINUOUS NO IGNITION CONTACT AN AUTHORISED TECHNICIAN gt DO NOT USE ANY INFLAMMABLE LIQUIDS FOR IGNITION Extraflame ENGLISH ADDITIONAL THERMOSTAT OPTIONAL The appliance can control the room temperature using an additional external thermostat optional After ignition pressing key 1 or via chrono mode the stove will work to reach the setting set on the thermostat displaying WORK contact closed The standard room probe is automatically ignored When the room temperature has been reached open contact the stove will go to minimum displaying MODULATE TO INSTALL AND ENABLE IT A mechanical or digital thermostat is required Remove the plug from the socket Referring to the figure to the side connect the two thermostat wires dry contact not 220 V on the relative terminals at the back of the machine one is red and the other one is black Power the stove Press key 5 setting the temperature on LOW The stove is now configured correctly It will work controlling the additional external thermostat gt INSTALLATION MUST BE PERFORMED BY OUALIFIED STAFF AND OR THE MANUFACTURER S TECHNICAL AFTER SALES ASSISTANCE THERE ARE TWO STOVE OPERATING MODES WHICH ARE DIFFERENT ACCORDING TO THE STAND BY FUNCTION SEE STAND BY CHAPTER USER MENU DIS
30. break Follow this procedure to extract the insert Open the door and turn the lockbolt in the corner at the bottom on the left anticlockwise Using the relevant pokers pull the machine towards yourself until it blocks automatically gt THE INSERT MUST ONLY BE EXTRACTED WHEN THE MACHINE IS SWITCHED OFF AND COMPLETELY COLD QExtraflame ENGLISH PELLETS The pellet used must comply with the features described by Standards EN PLUS UNI EN 16961 2 class Al or A2 0 7135 DINPLUS 51731 recommends using pellets with a diameter of 6mm with its products THE USE OF POOR QUALITY PELLETS OR ANY OTHER MATERIAL DAMAGES THE FUNCTIONS OF YOUR STOVE AND CAN gt VOID THE WARRANTY AND THE ANNEXED RESPONSIBILITY OF THE MANUFACTURER TO GUARANTEE COMBUSTION WITHOUT PROBLEMS THE PELLETS MUST BE KEPT IN A DRY PLACE FRONT PELLET FEEDING KIT OPTIONAL The optional pellet feeding kit allows pellets to be fed into the feed box from the front without having to extract the insert operation that requires machine switch off Further information on the accessories is x available on the website a www extraflame it support in the category ee accessories or IN THE EVENT OF INSTALLATION WITH FEEDING KIT OPTIONAL THE MACHINE MUST NOT BE EXTR
31. details the majolica the handles and the electric cables QExtraflame ENGLISH Colour variations crackles and slight size differences of the majolica parts are not a reason for claims as they are natural features of the materials themselves Parts made of refractory material Masonry work The system particulars for the production of domestic hot water not supplied by EXTRAFLAME S p A water products only The heat exchanger is excluded from the warranty unless an adequate anti condensate circuit which guarantees a minimum return temperature of the appliance of at least 55 C only water products FURTHER CLAUSES The warranty also excludes any calibration or regulation interventions of the product in relation to the type of fuel or the type of installation The warranty is not extended if particulars are replaced No compensation will be paid for the time the product is inefficient This warranty is valid only for the purchaser and cannot be transferred RECOMMENDED INSPECTION WITH PAYMENT EXTRAFLAME S p A recommends that the functional inspection of the product is performed by a qualified Technical After Sales Centre which will supply all information for correct use WARRANTY INTERVENTIONS The request for intervention must be sent to the dealer or after sales assistance Centre The warranty intervention envisions the repair of the appliance without any charge as provided by the law in force LIABILITY E
32. e do not put the bag of pellets to into contact with the product The majolicas are top quality artisan products and as such can have micro dots crackles and chromatic imperfections These features highlight their valuable nature Due to their different dilation coefficient they produce crackling which demonstrate their effective authenticity To clean the majolicas it is recommended to use a soft dry cloth If a detergent or liquid is used the latter could penetrate inside the crackles highlighting them 60 0 0 0 0 ROUTINE MAINTENANCE Based on Decree 22 January 2008 n 37 art 2 routine maintenance means interventions aimed at reducing degradation due to normal use as well as dealing with accidental events entailing the need of first interventions which however do not modify the structure of the system upon which one is intervening or its intended use according to the requirements laid down by the technical standards in force and by the manufacturer s use and maintenance manual Extraflame SAFETY DEVICES SAFETY DEVICES NOT PRESENT STOVES KEY PRESEN Circuit board it intervenes directly sending the product into alarm conditions until it has fully cooled down in the event of fumes motor breakage pellet feed motor breakage black out if above 10 seconds failed ignition Door micro switch With the door open the operation of the burn pot cleaning system is
33. east once a day To do this just use the relevant scrapers positioned in the upper part of the stove making upward movements and vice versa several times WEEKLY Cleaning the ash drawer Empty the ash drawer every week or when required It is recommended to remove the ash in the combustion chamber at least once a week using a suitable vacuum cleaner Extraflame ENGLISH CLEANING UNDER USER S RESPONSIBILITY The images are for illustration purposes MONTHLY Cleaning the heat exchanger The heat exchangers chamber must be cleaned every month as the soot deposited on the rear ofthe cast iron hearth wall blocks the regular flow of fumes To access the heat exchangers remove the front piece from the hearth wall following the operations described below Remove the burn pot from its seat Turn the lockbolt by 90 clockwise manually Take the removable cast iron part with your hands lift upwards and then pull it out of the combustion chamber by pulling it towards yourself paying attention to the 2 cast iron hooks at the bottom Remove the two cast iron parts at the base of the burn pot by pushing them towards each other
34. es must not be modified without the authorisation or indications of the manufacturer Do not pull disconnect twist electric cables leaving the stove even if disconnected from the electric power supply mains It is advised to position the power supply cable so that it does not come into contact with hot parts of the appliance The power supply plug must be accessible after installation Do not close or reduce the dimensions of the airing vents in the place of installation The airing vents are essential for correct combustion Do not leave the packaging elements within reach of children or unassisted disabled persons The hearth door must always be closed during normal functioning of the product When the appliance is functioning and hot to the touch especially all external surfaces attention must be paid Check for the presence of any obstructions before switching the appliance on following a prolonged period of inactivity The stove has been designed to function in any climatic condition even critical In particularly adverse conditions strong wind freezing safety systems may intervene that switch the stove off If this occurs contact the technical after sales service and always disable the safety systems In the event the flue catches fire use suitable systems for suffocating the flames or request help from the fire brigade This appliance must not be used to burn waste Do not use any flammable liquids for ignition During the filling phas
35. feet to adjust the desired height the bolts are positioned in the four external sides of the pedestal in the lower part Remember the power socket on the rear of the pedestal so that the plug is accessible once installation is completed Fix the pedestal to the floor using strong steel plugs with a diameter of 8 mm Fix the sliding base to the frame using bolts Connect the flue gas exhaust pipe and the air vent as stated in the previous paragraph Take the insert tilt it so that the wheels fit into the relative rails make it run until the flue gas auger is completely inserted into the flue gas conveyor box Finally open the fire door and use the supplied Allen key to turn the screw at the bottom left corner clockwise To understand whether the insert is correctly attached to the base connect the plug to the socket and make sure the display switches on N B If our pedestal is used a slot must be created in the flue that allows the pellet level in the feed box to be checked thus preventing spillage during filling Extraflame ENGLISH MOUNTING THE FRAMES As standard the insert has a finishing frame that as well as finishing covers the side slot required between the structure and covering P70 UPPER FRAME ASSEMBLY Simply fit the frame on the relevant pins as shown in figure 1 P70H49 UPPER FRAME ASSEMBLY The upper frame is fitted via 2 screws as shown in figure 2 SIDE
36. he start phase is in progress WORK The normal work phase is in progress MODULATION The stove is modulating BURN POT CLEANING The automatic burn pot cleaning is in progress When the stove is switched off final cleaning is in progress The f nal cleaning phase lasts about 10 FINAL CLEANING nisse STAND BY Stove off due to temperature reached and in stand by for re ignition EXT STAND BY Stove off due to an external thermostat in stand by for re ignition COOLING STAND BY A new ignition is attempted when the stove has just been switched off When the stove switches off one must wait for the complete shutdown of the fumes motor then clean the burn pot The stove can only be re ignited when these operations have been performed COOLING STAND BY The stove is cooling due to black out BLACK OUT Room thermostat set at minimum value LOW In this mode the stove only works at 1st power independently from the power set To exit this function just raise the room temperature using button 4 and then key 2 Room thermostat set at maximum value HOT The stove works at the set speed without ever modulating To exit this function just lower the set temperature using button 4 and then key 1 PELLETS LOW The PELLETS LOW message combined with key 1 flashing slowly indicates that the pellets tank is at minimum With the machine switched off and fully cooled down load the pellets tank Extrafl
37. indicated modalities TECHNICAL INSTALLATION DOCUMENTATION When installation is complete the installer must provide the owner or person acting for him according to the legislation in force with the declaration of conformity supplied with 1 the use and maintenance manual of the appliance and of the system components such as for example the smoke ducts chimney etc 2 photocopy or photograph of the chimney plaque 3 system booklet where applicable The installer must ask to be issued with a receipt stating that the documentation has been provided and must keep it with a copy of the technical documentation relating to the installation Installation performed by several parties If the individual installation steps are carried out by different parties each must document the work carried out for the customer and the for the operator working on the next step INSPECTION AND MAINTENANCE Frequency of operations Maintenance of the heating system and of the appliance must be carried out on a regular basis according to the table below TYPE OF APPLIANCE INSTALLED lt 15kW 15 35 kw Pellet operated appliance 1 year 1 year Water operated appliances 1 r 1 r closed fireplaces thermo stoves thermo kitchens yea yea Boilers 1 year 1 year Fumes exhaust system 4 t of fuel used 4 t of fuel used For further details refer to the cleaning and maintenance chapter Inspection and maintenance repo
38. lso bear in mind all laws and national regional provincial and town council Standards present in the country in which the appliance has been installed ENGLISH TERMS AND DEFINITIONS Aeration Air renewal is required both for the disposal of the combustion products and to prevent mixtures with a hazardous content of non combusted gases Closed hearth appliance Appliance designed for operation with closed combustion chamber Forced draught appliance Appliance with ventilation in the fumes circuit and combustion with fumes flow at a positive pressure with respect to the environment Chimney Structure consisting in one or several walls containing one or several outflow airways The purpose of this predominantly vertical element is to expel the combustion products at a convenient height from the ground Smoke duct Component or components that connect the outlet of the heat generator to the chimney Chimney cap Device that placed on the chimney outlet allows the dispersion of the combustion products even in presence of adverse weather conditions Condensation Liquid products which form when the fumes temperature is lower or equal to the water dew point Ducting pipe Pipe made up of one or several predominantly vertical elements specifically suitable for collecting and expelling the fumes as well as to withstand the relative components and any condensate over time suitable to be installed in a chimney existing or new
39. me any responsibility for any damages and consequent restore expenses of the above finishings even ifthe same occur following the replacement of malfunctioning parts THE WARRANTY IS VALIDATED ON THE CONDITION THAT EXTRAFLAME S p A assures that all its products are manufactured with top quality materials and with manufacturing techniques which guarantee total efficiency If during normal use of the product defective or malfunctioning parts are detected the partwill be replaced free of charge by the dealer who made the sale TERRITORIAL EXTENSION OF THE WARRANTY Italian territory VALIDITY THE WARRANTY IS CONSIDERED VALID ON THE CONDITION THAT The purchaser sends the attached coupon within 8 days from the purchase date filled in in all parts The purchase date must be validated by the possession of a valid fiscal document issued by the dealer The appliance is installed in compliance with the Standards in force on this subject the instructions contained in the provided manual and by professionally qualified staff The appliance is used as prescribed in the instructions manual provided with all products The warranty certificate has been filled in and signed by the customer validated by the dealer The warranty document filled in and accompanied by the purchase fiscal document issued by the dealer must be kept and shown to staff of the EXTRAFLAME S p A Technical After sales Service in the event of intervention THE WARR
40. me slot must Use keys 4 5 to enter the time 08 00 a Bn i which corresponds to the switch on START PRG1 PISO i 1 START PRG2 time of the 1st time slot 08 00 OFF The sequence to be followed is the To confirm and continue programming e RE T press button 6 Press button to go back to the previous parameter 2ND TIME SLOT SWITCH ON At this point the second time slot must be programmed The sequence to be followed is the same and is repeated as per the 15 TIME SLOT SWITCH ON On this occasion simply enter the time for example start at 15 00 and Stop at 22 00 and to activate the days Saturday and Sunday by setting them at WHEN THE WEEKLY PROGRAMMER IS ACTIVE A BOX OF THE RELATIVE ICON WILL APPEAR ON THE o CONTROL BOARD QExtraflame ENGLISH CLEANING UNDER USER S RESPONSIBILITY The images are for illustration purposes DAILY Burn pot Remove the burn pot from the relevant compartment and free the holes using the special poker supplied remove the ash from the burn pot using a vacuum cleaner Vacuum the ash deposited in the brazier compartment Scrapers The heat exchangers must only be cleaned when the stove is cold Cleaning the heat exchangers allows to ensure constant heat output over time This type of maintenance must be performed at l
41. nd only at the set power ADJUSTING POWER SETTING The power setting features 5 operating levels via button 5 access 1 and 2 adjustment Power 1 minimum level Power 5 maximum level WORK WITH ROOM PROBE STANDARD The appliance controls the room temperature via a probe fitted on the appliance Once the the set temperature has been reached it will automatically go to minimum or switch off activating the Stand by function reducing pellet consumption to a minimum By default the STBY function is always set on OFF light o on For its activation and logic follow the indications on the next page chapter Stand by BURN POT CLEANING During the work stage the stove has an internal counter which cleans the burn pot after a set amount of time This stage will be shown on the display it will bring the stove to a lower power level and will increase the fumes motor for a programmed amount of time When the cleaning stage is finished the stove will continue its work going back to the selected power level SWITCH OFF Press key 1 for three seconds When the operation has been performed the appliance automatically enters the switch off phase blocking the supply of pellets The fumes motor and the hot air ventilation motor will remain on until the temperature of the stove has dropped below the factory parameters RE IGNITION The stove can only be re ignited if the flue gas temperature has lowered and the preset timer has
42. nsert support pedestal optional kit in fact the latter attaches the insert to the floor COMPONENTS DESCRIPTION T A Primary air intake pipe B Flue exhaust pipe C Adaptation frame D Sliding base and rails MINIMUM DIMENSIONS P70 P70H49 MINIMUM 500 X 720mm WITHOUT OPTIONAL DRAWER MINIMUM 570 X 720mm WITH OPTIONAL DRAWER MINIMUM 570 X 720MM WITH OR WITHOUT OPTIONAL DRAWER IF N 1 1 58 720 8 m 720 gt Extraflame ENGLISH 7 2 A i 1 VY 7 N m Ls 1 nd gt LF lt 22 i be 225 270 225 V 72 720 Li 2 AIR CIRCULATION PIPES Create air recirculation inside the structure that covers the insert for correct operation This prevents the appliance from over heating To guarantee this just make one or more openings in the lower and upper parts of the covering The following measurements must be respected LOWER PART COLD AIR INLET WITH TOTAL MINIMUM SURFACE 550 CM UPPER PART HOT AIR OUTLET WITH TOTAL MINIMUM SURFACE 550
43. ration of rain and snow in the chimney ducted system they must be built so that in the event of winds coming from all directions and from any angle the expulsion of combustion products is in any case ensured they must be free from mechanical intake aids Extraflame ENGLISH COMBUSTION PRODUCTS OUTLET OUOTA The outlet guota is determined by measuring the minimum height between the roof covering and the lower point of the fumes expulsion section into the atmosphere this quota must be outside the reflux area and at an adequate distance from obstacles which hinder or make the expulsion of the combustion products difficult or from openings or accessible areas Reflux area The outlet guota must be outside the reflux area calculated according to the indications below Near the ridge one considers the lowest between the two Buffer area for outlet guota Clear area for outlet quota above the roof slope 4 gt 10 REFERENCE DESCRIPTION CLEAR AREA MM Distance measured at 90 from the roof surface 1300 a Height above the ridge of the roof 500 The outlet of a chimney ducted system must not be near obstacles that may create turbulence areas and or prevent proper expulsion of combustion products and maintenance operations to be carried out on the roof Verify the presence of other chimney caps or skylights and dormers FUMES EXHAUS
44. rt At the end of the inspection and or maintenance operations a report must be issued and released to the owner or person acting for him who must confirm its receipt in writing The report must indicate the situations encountered the action taken any components replaced or installed and any comments recommendations and requirements The report must be kept with the relative documentation In the inspection and maintenance report one must mention anomalies detected that cannot be removed which pose a risk to the safety of the user or serious damage to building components that have been tampered with If anomalies as per above were detected the owner or person acting for him must be warned in writing in the maintenance report to refrain from using the system until the safety conditions have been fully restored The inspection and maintenance report must include the main information of the technician or company who performed the inspection and or maintenance operations with their contact details date of intervention and the signature of the operator Extraflame ENGLISH COMFORT P70 P70H49 INSTALLATION The insert is supplied with a sliding metal base that allows it to be installed in a pre existing flue The sliding base allows the easy extraction of the insert both for feeding pellets into the feed box and for any maintenance or cleaning at the end of the season If there is no pre existing flue it can be built using the i
45. s a very high flame even at low power the panoramic glass is very dirty obscuring it almost totally the burn pot tends to become encrusted blocking the holes for air intake due to the excessive pellet feed as it is only burned partially The adjustment to be performed is in percentage Therefore changing this parameter will lead to a proportional variation of all stove feeding speeds Feeding is from 20 to 30 Follow the procedure on the display to perform the procedure CONTROLS PROCEDURE Press key 6 and SET CLOCK will appear Press key 2 several times until USER is displayed Press key 6 DISPLAY will appear Press key 2 until PELLET appears Use keys 4 increase 5 to 4 or decrease 5 the load during the WORK stage Press key 6 to confirm and key 1 to return to the previous menus up to the initial status V1 AIR The menu allows to adjust the speed of the front fan in percentage CONTROLS PROCEDURE Press key 6 and SET CLOCK will appear Press key 2 several times until USER is displayed CZ Press key 6 DISPLAY will appear C Press key 2 until V1 AIR appears Use keys 4 5 to increase 4 or decrease 5 1 Press key 6 to confirm and key 1 to return to the previous menus up to the initial status 0 0 0 0 6 STAND BY STAND BY WITH DIGITAL THERMOSTAT STANDARD STBY FUNCTION SET AT ON If the Stby function is active ON when the stove reaches the se
46. s exhaust system assembly and installation electric and hydraulic connections installation of insulation ignition and operation test installation of finishings and coverings 0 3 Issue of complementary documentation 4 Inspection and maintenance Other actions may be required in relation to specific requests ofthe competent authority PRELIMINARY ACTIVITIES GENERAL Verification of compatibility of the system of any restrictions required by local administrative regulations special or conventional requirements resulting from condominium regulations constraints laws or administration deeds must precede any other assembly or installation operation One must especially verify the suitability of the installation premises of the appliances already installed in the installation premises and in the adjacent and adjoining premises also powered by different fuels with particular reference to non compliant installations of the fumes exhaust system of the outside air inlets SUITABILITY OF THE FUMES EXHAUST SYSTEM Installation must be preceded by a compatibility test between the appliance and the fumes exhaust system by verifying the existence of documentation relating to the system existence and content of the chimney plaque suitability of the internal section of the chimney absence of obstructions all along the chimney predominantly vertical height and development of the chimney exi
47. stance of combustible materials from the intrados of the framework floor wall 500 b 1 Minimum distance of combustible materials from the extrados of the framework floor 500 a Minimum distance from combustible materials defined by the manufacturer G xxx The single wall pipes are indicated in white The insulated double wall chimney systems are indicated in grey One can disregard the quota only in the event of using an appropriate heat protection screen for example wall plate to protect the intrados of the framework floor SMOKE DUCT General requirements The smoke ducts must be installed in compliance with the following general requirements they must be insulated if they cross through rooms that are not to be heated or outside the building they must not cross rooms in which the installation of combustion appliances is forbidden nor in other premises compartmentalised against fire or with a fire hazard nor in rooms and or areas that cannot be inspected they must be installed so as to allow normal thermal expansion they must be fitted to the opening of the chimney without protruding inwards the use of flexible metal pipes to connect the appliance to the chimney is not allowed NY gt lt gt lt sor Chimney ya 22 e x Incorrect 227 lid 4 7 Correct lt 7 of
48. stence and suitability of the chimney cap distance of the outside wall of the chimney and of the smoke duct from combustible materials chimney type and material absence of other chimney connections 999999 Extraflame ENGLISH INSTALLATION Installation in premises with fire hazards is forbidden Installation in residential premises except for sealed operation appliances is also forbidden in which there are liquid fuel operated appliances with continuous or intermittent operation which draw the combustion air in the room in which they are installed or inwhich there are type gas appliances intended for room heating with or without production of domestic hot water and in adjacent and adjoining premises or in which in any case the depression measured during installation between the internal and external environment is greater than 4 Pa Installations in bathrooms bedrooms and studio flats Installation in bathrooms bedrooms and studio flats is only allowed for sealed or closed hearth appliances with ducted combustion air taken from the outside Installation premises requirements The support surfaces and or points must have a suitable load bearing capacity to support the weight of the appliance of the accessories and coatings The adjacent side and rear walls and the supporting surface must be made of non combustible material according to the table REFERENCES INFLAMMABLE OBJE
49. t be followed the first Before lighting the stove the following points must be times the stove is ignited verified Faint smells may be produced due to the drying ofthe hydraulic system must be completed in compliance paints and silicones used Do not remain in the environment with the guidelines of the regulations and the manual for long periods The tank must be full of pellets not touch the surfaces as they could still be combustion chamber must be clean unstable pot must be completely free and clean Air the room well several times Check the hermetic closure of the fire door and the ash The hardening of the surfaces is terminated after drawer several heating processes Check that the power supply cable is connected correctly This appliance must not be used to burn waste The bipolar switch in the rear right part must be positioned on 1 BURN POT DIVIDER IT IS FORBIDDEN TO USE THE APPLIANCE WITHOUT THE DIVIDER AND OR GLASS PROTECTION SEE THE FIGURE TO THE SIDE ITS REMOVAL JEOPARDISES THE SAFETY OF THE PRODUCT AND i gt IMMEDIATELY VOIDS THE WARRANTY PERIOD INTHE EVENT OF WEAR OR DETERIORATION CONTACT THE ASSISTANCE SERVICE TO REPLACE THE PART THE REPLACEMENT IS NOT COVERED BY THE PRODUCT WARRANTY AS IS A PART SUBJECT TO WEAR GLASS PROTECTION u lt Extraflame ENGLISH THE REMOTE CONTROL All that can normally be implemented through the LCD c
50. t room temperature and exceeds it by 2 C it will switch off after a default delay time displaying stand by When the room temperature is 2 C lower than the setting and once the stove has cooled it will start to work again at the set power and displaying work Extraflame ENGLISH STBY FUNCTION SET AT OFF DEFAULT SETT NG If the Stby function is not active OFF if the stove reaches the set room temperature it will go to minimum modulating and displaying modulate When the room temperature is below the setting it will start to work again at the set power and displaying work STAND BY WITH ADDITIONAL THERMOSTAT The STBY function is used if immediate stove switch off is required when the set temperature has been reached By default the STBY function is always set on OFF light o on e STBYFUNCTION SET AT OFF DEFAULT SETTING If the STBY function is not active OFF if the stove reaches the set room temperature it will go to minimum modulating and displaying MODULATE When the room temperature is below the setting it will start to work again at the set power and displaying WORK STBY FUNCTION SET AT ON When the STBY function is activated ON the stove upon reaching the set room temperature and exceeding it by 2 C will switch off after a pre set default delay displaying STAND BY When the room temperature is 2 C lower than the setting the stove will start to work again at the set power displaying WORK
51. t time slot from 08 00 to 12 00 every day of the week with room temperature at 19 C excluding Saturday and Sunday 2nd time slot from 15 00 to 22 00 only on Saturday and Sunday with room temperature setting of 21 C 1ST TIME SLOT SWITCH OFF CONTROLS PROCEDURE SET CLOCK Use keys 4 5 to enter the time 12 00 which corresponds to the switch off STOP PRG1 time of the 1st time slot 12 00 To confirm and continue programming S once CEE wil press button 6 Press button 3 to go ESCE SETTING back to the previous parameter Press key 2 until SET CHRONO appears ENABLING THE 1ST TIME SLOT DAYS ENABLE CHRONO To enable disable the days use keys 4 N i MONDAY PRG1 Press key 6 ENABLE CHRONO and OFF ENABLE CHRONO and 5 key 2 and 3 to scroll the various NE will appear ON days the day of the week will appear followed by OFF select from Monday to Friday on ON excluding Saturday and Sunday OFF Press key 4 to activate or disable the CHRONO function Select ON 1ST TIME SLOT H20 TEMPERATURE SETTING Press key 6 to confirm and continue START PRG1 Press key 6 to confirm and continue programming OFF programming SET PRG1 Using buttons 4 5 select the desired 19 C START PRG1 OFF will appear temperature Low 07 40 C Hot To confirm and proceed press key 6 1ST TIME SLOT SWITCH ON END UME SONS ICON At this point the second ti
52. uExtraflame Riscaldamento a Pellet COMFORT P70 amp P70 H49 INSERT USER MANUAL ENGLISH INGLESE OExtraflame OExtraflame We thank you for having chosen our company our product is a great heating solution developed from the most advanced technology with top quality machining and modern design aimed at making you enjoy the fantastic sensation that the heat of a flame gives in complete safety Extraflame S p A ENGLISH 4 INSTALLATION 200200000000000000n000n00n0nesunssnnnnonsnsnnsnonesnnnsnnnssanennnssnnnsnnnsnnnsnnnnsnnnsnsnsnnnssnnssnnnsnnnsnnnnsnnnsnnnsnnnsnnnnsnnsssnnsnnnnsnnnsnnsssnnnsnnnsne FUMES EXHAUST SYSTEM s00sssosesonssonssonsssnnenonenonnsnnnssonennnssnnnennnsnnnennnnsnnnsnnnsnnnssnnnsnnnennnsnnnnsnnnsnnnsnnnsnnnnsnnnsnnnsnnnnsnnnsnnsssnnnannnnne GENERAL REQUIREMENTS SMOKE DUCT un a AMAN CHIMNEY CAPS AN EEE EM EDE RA L ME a eat FUMES EXHAUST SYSTEM PRODUCT REOUIREMENTS COMBUSTION PRODUCTS OUTLET QUOTA rivi einer renali rn 5 DOCUMENTATION Ei ae nn kn benennen COMFORT 70 7 49 INSTALLATION sn sie MINIMUM DIMENSIONS 2
53. which it has been expressly designed The manufacturer is exempt from any liability contractual and extracontractual for injury damage caused to persons animals and objects due to installation adjustment and maintenance errors and improper use Installation must be performed by qualified staff which assumes complete responsibility for the definitive installation and consequent good functioning of the product installed One must also bear in mind all laws and national regional provincial and town council Standards present in the country in which the appliance has been installed Extraflame S p A cannot be held responsible for the failure to comply with such precautions After removing the packaging ensure that the content is intact and complete Otherwise contact the dealer where the appliance was purchased All electric components that make up the product must be replaced with original spare parts exclusively by an authorised after sales centre thus guaranteeing correct functioning SAFETY The stove must not be used by persons including children with reduced physical sensory and mental capacities or who are unskilled persons unless they are supervised and trained regarding use of the appliance by a person responsible for their safety Children must be checked to ensure that they do not play with the appliance Do not touch the stove when you are barefoot or when parts of the body are wet or damp The safety and adjustment devic
54. ws to reset all values modifiable by the user to the default values The modified data is the following SET TEMPERATURE 35 C CONTROLS PROCEDURE SET POWER 5 Press SET CLOCK will appear ENABLE CHRONO OFF Press key 2 several times until USER is displayed E MONDAY PRG1 OFF DISPLAY will appear all chrono parameters OFF Press key 2 until RESET appears PELLET 00 Press keys 4 5 to select ON and press key 6 STAND BY OFF DONE will appear on the display to confirm e VIAIR 0 V2AIR 0 CHRONO The chrono allows to program 4 time spans within a day to use every day of the week The switch on and switch off time can be set in every time slot along with the days of use of the programmed time slot and the desired room temperature 07 40 C RECOMMENDATIONS The ignition and switch off times must be within the arc of one day from 0 to 24 and not over several days Before using the chrono function set the current day and time Therefore check that the points listed in the Set clock sub chapter have been followed so that the chrono function works Aside from programming it activate it as well EXAMPLE SWITCH ON TIME 07 00 11223 SWITCH OFF TIME 18 00 CORRECT SWITCH OFF 05 00 NCORRECT QExtraflame ENGLISH PROGRAMMING EXAMPLE Let s suppose that the weekly Programmer function is to be used and 4 time slots are to be used in the following way 1s