Home
LC-004-600 User Manual DALI CS Combination Sensor.indd
Contents
1. be installed in recessed conduit boxes or directly on cavity walls 14 The DALI CS must not be connected to the mains It is directly supplied by the DALI line PIR Motion Detection sensibility 92 zones distance lt 12m range hor 51 vert 46 temp diff target to ambience gt 4 C Light Intensity Measurement range 0 2500lux resolution 1lux Temperature Measurement range 0 C 70 C resolution 1 C optional on request IR or RF Remote Control Receiver Functionality and Configuration The DALI CS measures various physical properties motion light intensity and temperature and offers the possibility to react according to the measurements by sending DALI commands Via a DALI USB interface the software tool DALI Cockpit can communicate with the DALI CS So the desired functionality can be configured easily on PC DALI Cockpit and DALI USB interface are required for the configuration only and can be removed when configuration is finished For further details check the DALI tutorial and DALI CS and DALI Cockpit manuals The settings of the sensor components and the configuration of the DALI commands and destination addresses can be defined in the DALI Cockpit Before going in detail the functionality of the sensors and the basic operating conditions of the DALI CS will be explained Motion Detection The motion sensor is spatially divided into 92 zones In each zone the received thermal radiation is determ
2. configuration may be sufficient The destination address can be set by the rotary switch on the rear side of the sensor 0 Broadcast 1 15 gt group addresses GO G14 In the default configuration light and temperature sensor are deactivated The motion sensor sends the DALI command RECALL MAX in case of a detected motion and the DALI command OFF without delay if movement isn t detected any longer The destination address is GO G14 or broadcast as selected by the rotary switch For any other configuration the free DALICockpit software tool can be used to adjust the sensor individually In the DALI Cockpit the DALI addressing procedure can easily be initiated After addressing has finished the spatial localization of any DALI CS can be done by forcing the desired sensor to turn on a red LED Therefore select the check box to switch on the LED in the DALI Cockpit The relationship between spatial arrangement and assigned number in the software is simply established that way The parameters like threshold and hysteresis of light intensity measurement and temperature sensor can be configured in the DALI Cockpit as well as the delay time of the PIR sensor Moreover each sensor can be separately enabled or disabled When a defined event such as crossing temperature thresholds or detected motion occurs each sensor module can send freely configurable DALI commands Send Cmd X Y to up to four destination addresses In contrast to the de
3. LED DALI CS Combination Sensor User Manual Item No LC 004 600 1 Product Description The DALI CS Combination Sensor is a Sensor unit for automatic lighting control in DALI systems wit integrated Licht intensiry measurement and additional temperature sensor for measuring and monitioring the room temperature The compact module can be mounted in a flush box or directly on cavity walls 2 Specifications shellcolor RAL9010 0 5 1 5 mm2 Dimensions L x W x H in mm 98 x 9 x 30 mm 489 3 Description 1 Sensor Module for DALI lighting systems with focus on automatic lighting control and low energy costs 2 Motion detection 3 Light intensity measurement 4 Lighting control dependent on motion 5 Ambient light dependent control 6 Sensor for ambient temperature measurement and monitoring 7 Optional an integrated IR or RF remote control receiver is available 8 The DALI CS module can be used either as active lighting control unit or just for measurements and monitoring 9 Sensor properties are set easily via the DALI line and the DALI Cockpit software tool 10 The DALI CS is able to transmit DALlcommands e g ON OFF RECALL MIN MAX GO TO SCENE X to single destination addresses group addresses or broadcast 11 The rotary switch on the back of the housing helps to assign a destination group address easily 12 Several DALI CS modules can be used within one DALI line 13 The compact module can easily
4. ckpit switching threshholds for light intensity can be defined by setting values for th reshold and hysteresis When the measured value falls below the lower limit or exceeds the upper one various DALIcommands can be selected to be sent as response Send Cmd Y threshold t Y Lightlevel lux hysteresis Send Cmd X hysteresis light sensor Besides direct lighting control the light sensor can be used for measurement and monitoring as well The measured value can be transmitted to a superimposed control A combined functionality of light intensity sensor and motion detector can be selected optionally With this option the motion sensor can be forced to work only at night while it is deactivated during daytime Temperature Measurement The temperature sensor covers a range from 0 C to 70 C The resolution is 1 C The setting of switching thresholds is implemented similar to the light sensor The temperature sensor can be used for measurement and monitoring purposes only The measured value can then be transmitted to a higher level controller Send Cmd Y threshold ji Y Temperature PC hysteresis Send Cmd X hysteresis temperature sensor Optional Sensors On request the DALI CS is available with infrared IR or radio frequency RF remote control receiver The transmission of DALI commands can then be manually triggered by a remote control Configuration For applications requiring a motion sensor only the default
5. fault setting multiple destination addresses can be selected These can be either individual addresses or group addresses as well as broadcast Besides the destination addresses the DALlcommand to be transmitted must also be selected Available DALI commands can be separated into commands for Switching On CmdX and Switching Off CmdY CmdX ON commands DIRECT ARC direct arc power in POWER gt 0 RECALL MAX recalls MAX value ON AND STEP Increases light level by one UP increment if OFF switch ON MIN value GO TO SCENE go to scene 0 15 6 RECALL MIN recalls MIN value CmdY OFF commands DIRECT ARC direct arc power in POWER gt O If there is no destination address no DALI commands will be sent The DALI CS may be used for measurement and monitoring purposes in this mode The measured values can be retrieved using special commands For more details check the DALI CS manual 4 Abmessungen l 9 mm 8 mm 30 mm 46 mm samm 20 5 mm Installation The DALI CS module is connected to the DALIline Like all DALI modules it is powered directly via the DALI signal line which is supplied by a DALI PS A separate power supply is not needed A typical value for the current consumption is 3 5mA The DALI line input is polarity free and protected against overvoltage of up to 270Vac DALI signals are not SELV Therefore the same procedures should be applied as working with main voltage Al
6. ined and differentially compared to the adjacent zones PIR sensor For motion detection there is aneed for a temperature difference of at least 4 C between moving object and environment Heat sources such as copiers or heaters may have a negative influence on motion detection This method allows observation of relatively large areas by using only one sensor head With opening angles of 46 3 and 51 3 and a sensor mounted at a height of 5 meters the 92 zones cover an area of more than 100m2 The distance between sensor and the object of interest should be less than 12 meters 13 8 m 10m 5m 5m 10m opening angel detection area The DALI CS can send DALI commands on movement detection as well as on disappearance of a previ ously detected motion In the case of the disappearance of a previously detected motion a delay time between the occurrence of the event and the transmission of the DALI command can be defined I A Ki Le _ 2 0 Status Detected Delay Send Cmd X Send Cmd Y This functionality offers a simple and convenient way to implement an automatic lighting control The light is turned on and off as reaction on motion Light Intensity Sensor The light sensor measures illuminance in a range from 0 to 2500 lux The resolution is 1 lux The incident light is rated by the spectral sensitivity of the human eye and thus a property for the subjective visual perception of brightness In the DALI Co
7. lowed connection wire cross sections range from 0 5mm2 to 1 5mm2 The DALI CS mounting ring can be attached to cavity walls directly or by using an electrical box The housing can then simply be attached on the mounting ring Even in a flush mounted box there is enough room for a sunken sensor head Finally the sensor head can be aligned to the desired position Declination angles of 40 in vertical and 360 in axial direction are provided 5 Safety Warnings 6 1 To avoid installed the product in minefield strong magnetic field and high voltage area 6 2 To ensure the wiring is correct and firm avoiding short circuit damages to components and cause fire 6 3 Please install the product in a well ventilated area to ensure appropriate temperature environment 6 4 The product must be worked with DC constant voltage power supply Please check the consistence of input power with the product if the output voltage of the power comply with that of the product 6 5 Connect the wire with the power on is forbidden Ensure proper wiring first then check to ensure no short circuit then power on 6 6 Don t repair it by yourself whenever an error occur Contact the supplier for any inquiry sensor head sunken and extended aligned sensor head 6 Wiring Diagram DALI CS Kombisensor Combination Sensor LC 004 600 DALI PS1 Bus Stromversorgung Deckeneinwurf Bus Power Supply In Ceiling Void LC 004 100