Home

User Manual for 2nd Generation Gloves

image

Contents

1. CTHERMOLOGIDC gt THERMOLOGIC INSTRUCTION MANUAL HEATED GLOVE USER S GUIDE MODEL T 137 HEATED GLOVE WWW THERMOLOGICGEAR COM IMPORTANT NOTICE Thank you for choosing ThermoLogic powered cold weather gear As with any electrical device misuse of a ThermoLogic glove or failure to follow instructions may cause overheating fire or injury to you or your property Please read glove labels and all instructions before using your ThermoLogic glove Always keep the batteries out of reach of children OVERVIEW Battery Type Lithium lon 300 recharging cycles Battery Capacity 7 4 1250mAh Lithium lon Battery Storage Store at temperatures between 41 F 5 C and 86 F 30 C Ideal storage temperature is 68 77 F 20 C 25 C Heating Method Electric current pulsed through metal clad polymer fiber filament Temperature Settings High 115 Medium 100 Low 85 Heat Times Estimated 2 25 hours at High 3 25 hours at Medium 4 25 hours at Low Charger 8 4V 1 5Amp output 100V 240V Input Charging Time 3hrs for 1 battery 4 hrs for 2 batteries CHARGING THE BATTERIES HOW TO CHARGE Before initial use fully charge the batteries The Charger has a split cord so you can charge both batteries at the same time Batteries can also be charged individually If you choose to charge only one at a time do not plug in second unit midway through charging cycle This can be damaging to the
2. DS HEALTH If you experience any discomfort while wearing this item remove it immedi ately and consult your physician before resuming use Do not use if you have a pacemaker or defibrillator Check with your physician before use if you e Have a heart condition e Have diabetes e Have circulatory problems e Have sensitivity to heat Are pregnant Are under 13 years of age ADDITIONAL WARNINGS Do not submerge ThermoLogic glove in water while wearing e Keep battery in waterproof pocket at all times This ensures safety and reliability when wearing glove in the rain Do not cut puncture or tear the lining of the ThermoLogic glove The lining includes the heated filaments which may be damaged and may affect the heating ability of your Thermologic glove e Keep battery used with your ThermoLogic glove dry at all times If the battery gets wet do not turn it on Allow it to dry completely in a cool dry space and try activating battery before re inserting into your glove Like any electrical item battery may be damaged if submerged in water e Keep all components used with your ThermoLogic glove away from fire and significant sources of heat Store in doors away from direct heat sources See battery storage guidelines in Overview section e Glove and components may not activate if frozen or stored in extreme cold Should that happen allow them to thaw and or warm up before attempting to activate e When turned on this glov
3. batteries NOTE When the batteries are charging the light on the charger is red The light will turn green part way through the charge cycle Do not unplug prematurely batteries must charge the full length of time see Overview to be fully charged 110V 240V Outlet WHEN TO RECHARGE Fully charge the battery before each use for best performance The lithium ion battery will naturally discharge itself over time It is best to charge it within two days of use It is also recommended to fully charge the batteries before storing them for extended periods of time Store the batteries in a dry cool location temperature no higher than 86 F 30 C The lithium ion battery is rated for 300 recharge cycles before you will need to replace it Like other rechargeable batteries these batteries may eventually require replacement Contact ThermoLogic directly at 877 945 6837 or go to our web site at thermologicgear com to order additional batteries GETTING STARTED ASSEMBLY 1 Open the zipper pocket 2 Locate and gently pull out Glove connector plug 3 Attach Glove connector plug to the Battery connector socket push firmly together to connect 4 Gently insert Battery into zipper pocket Orient Battery so that the connected plug and socket are parallel to the zipper 5 Close the zipper pocket ACTIVATION Press and hold the heat control button on back of thumb for 3 seconds The Low L LED light will illuminate green indicating
4. e may affect compasses or magnetic sensing equipment e Your ThermoLogic glove is not intended for use in warm weather Using your ThermoLogic glove at temperatures above 65 F may place YOU at risk of overheating e Ifyou are going to store your ThermoLogic battery for long periods of time in between seasons we recommend that you fully charge the battery before storage PLEASE REVIEW YOUR WARRANTY ANY MISUSE OF YOUR THERMOLOGIC GLOVE WILL VOID YOUR WARRANTY THERMOLOGIC 1 YEAR LIMITED WARRANTY NTA Enterprises Inc NTA warrants to the original retail purchaser that this ThermoLogic glove the Product will be free of defects in materials and workmanship for a period of one 1 year from the date of initial purchase the Warranty Period NTA at its option will repair or replace the Product or any part of the Product that is defective during the warranty period Replacements will be made with a new or remanufactured Product If the Product is no longer available NTA may replace the Product with a similar product of equal or greater value This LIMITED WARRANTY is the exclusive warranty for the Product and it is valid only during the Warranty Period to the original retail purchaser and is not transferable Proof of purchase is required to obtain performance of this LIMITED WARRANTY Proof of purchase may be provided to us with the original sales receipt for the product through registration on NTA s web site t
5. hermologicgear com or by returning the attached warranty card Retailers and other resellers of the Product do not have authority to alter modify amend or otherwise change the terms of this warranty This LIMITED WARRANTY does NOT cover damage or wear resulting from negligent use or misuse of the Product use with any battery not provided or approved by NTA for use with the Product use contrary to the operating instructions of the Product disassembly or repair or alteration by anyone other than NTA or its authorized agent NTA DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW IF REQUIRED AND PERMITTED BY LAW ANY IMPLIED WARRANTY IS LIMITED IN DURATION TO ONE 1 YEAR FROM THE DATE OF INITIAL RETAIL PURCHASE NTA SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY ALLEGED BREACH OF WARRANTY SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF CONSEQUEN TIAL DAMAGES OR A LIMITATION ON THE DURATION OF AN IMPLIED WARRANTY SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY HAVE RIGHTS THAT VARY FROM STATE TO STATE SERVICE INSTRUCTIONS TO OBTAIN WARRANTY SERVICE Do not return the product to place of purchase for warranty service If you have any problems questions or to obtain instructions for returning the product to us for warranty service contact us through our web site at thermologicgear co
6. m or call us at 1 877 945 6837 We are here to help TROUBLESHOOTING If the lights flash L M H this is a sign that the battery needs to be recharged If this happens recharge the battery
7. that the unit is on and the temperature is set to Low puhand _ TEMPERATURE ADJUSTMENT To change the old for 3 Seconds Peat setting momentarily press and release the heat control button This will toggle between heat settings The LED light on the battery will switch from L Low to M Medium to H High each time you press and release the HEAT button LED light will indicate temperature selected TO SHUT DOWN Press and hold the heat control button for 3 seconds The LED light will turn off When the battery runs low the indicator will alternately flash the L M H settings This indicates it is time to recharge the battery Extra batteries are available at www thermologicgear com TO RECHARGE Remove battery from zipper pocket and disconnect from glove plug connector Connect charger cord to battery Allow battery to fully recharge before resuming use Follow instructions listed in How to Charge NOTE If the lights flash L M H this is a sign that the battery needs to be recharged WASH amp CARE IMPORTANT PREPARING GLOVE FOR WASHING Remove batteries from glove and close the zipper pocket prior to hand spot washing WASHING INSTRUCTIONS Do NOT SUBMERGE IN WATER Gently spot clean with a damp soapy wash cloth Line Dry Do NOT machine wash Do NOT bleach Do NOT tumble dry Do NOT iron Do NOT dry clean Keep batteries and connector plugs away from water PI Hk Bt BS RL WARNINGS AND SAFEGUAR

Download Pdf Manuals

image

Related Search

Related Contents

    User Manual - Grandbeing  

Copyright © All rights reserved.
Failed to retrieve file