1. 2 A Welcome screen displays prompting you to in m stall the driver Click Next Welcome to the MDMouse Setup Wizard The installer will guide you through the steps required to install MDMouse on your computer WARNING This computer program is protected by copyright law and international treaties Unauthorized duplication or distribution of this program or any portion of it may result in severe civil or criminal penalties and will be prosecuted to the maximum extent possible under the law Cancel i 3 Inthe license agreement screen click Yes to agree to the terms and continue i MDMouse License Agreement Please take a moment to read the license agreement now If you accept the terms below click I Agree then Next Otherwise click Cancel Software License Agreement End User License Agreement for CalHealth software for use with an MDMouseTM blood pressure monitoring system This End User License Agreement ts a legal agreement between you either individual or single entity and CalHealth Inc for the MDMouse software YOU AGREE TO BE BOUND BY THE TERMS OF THIS AGREEMENT BY INSTALLING OR COPYING y C IDo Not Agree MDMouse User Manual Model MD 100 4 Accept the default installation location or click Browse to select one Click Disk Space to view the hard disk space required for the installation and the disk space available on your computer Click Next to start installing the MDMouse appli cation
2. 5 Click Next to start the installation process After the MDMouse application is installed successfully click Finish 6 If prompted to install the device driver click In stall to continue 7 After device driver installation is complete a pop up window displays Click OK i MDMouse Select Installation Folder The installer will install MD Mouse to the following folder To install in this folder click Next To install to a different folder enter it below or click Browse Folder C Program Files CalHealths MD Mouse Browse Disk Cost Install MDMouse for yourself or for anyone who uses this computer Everyone Just me Cancel lt Back i i MDMouse Confirm Installation The installer is ready to install MDMouse on your computer Click Next to start the installation Cancel lt Back f s Silicon Laboratories CP210x USB to UART Bridge Driver Installer Silicon Laboratories 7 Silicon Laboratories CP210x USB to UART Bridge Installation Location Driver Version 5 3 C Program Files Silabs MCUNCPZ10x Change Install Location ji MDMouse Installation Complete MDMouse has been successfully installed Click Close to exit Please use Windows Update to check for any critical updates to the NET Framework MDMouse User Manual Model MD 100 8 After the device driver installation is complete click Close to close the window um 9 Hook up the MDMous
3. IEC60601 1 2005 CORR 1 2006 CORR 2 2007 EN 60601 1 2006 AC 2010 Medical electrical equipment Part 1 General requirements for basic safety and essential Performance EN1060 3 1997 A1 2005 A2 2009 Non invasive sohygmomanometers Part 3 Supplementary re quirements for electromechanical blood pressure measuring systems EN1060 4 2004 Non invasive sohygmomanometers Test procedures to determine the overall system accuracy of automated non invasive sohygmomanometers IEC EN 60601 1 11 General requirements for basic safety and essential performance Collateral Standard Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment IEC 80601 2 30 2009 First Edition for use in conjunction with IEC 60601 1 2005 EN 80601 2 30 2010 ANSI AAMI 80601 2 30 2009 Particular requirements for the basic safety and essential performance of automated non invasive sohygmomanometers EN60601 1 2 2007 AC 2010 Medical electrical equipment Part 1 2 General requirements for basic safety and essential performance collateral standard electromagnetic compatibility EN 55011Group 1 Class B 2009 A1 2010 Industrial scientific and medical equipment Ra dio frequency disturbance characteristics Limits and methods of measurement FCC 47CFR PART 15B AND ANSI C63 4 2003 EN ISO 10993 1 2009 Biological evaluation of medical devices Part 1 Evaluation and testing within a
4. The pop up notification screen displays only when you have opened the MDMouse application If the MDMouse application is not running when the time is reached you will not be notified 16 MDMouse User Manual Model MD 100 Data Management and Personal Health Records Data Storage Use the Data Storage menu to set the MDMouse application to ET Te send your blood pressure measurements to a selected location FE cece By default the results are stored on your computer WPD The following describes the storage location options available e Local PC only Stores your blood pressure measurements on your computer This is the default setting e Nomore Clipboard Sends and stores your blood pressure measurements to your Nomore Clipboard account You should have already created a user account on www nomoreclipboard com and specified your account information in the User Profile screen e WPD Sends and stores your blood pressure measurements to Microsoft HealthVault using the Windows Portable Device WPD technology Refer to www healthvault com for de tailed information on this service and how to create a user account Nomore Clipboard You can set the MDMouse application to send your blood pressure measurements to no moreclipboard com an online health information management system You will need to create an account from the Web site and enter your account information in the User Profile screen Refer to the instru
5. pound Reminder Disable feet Reminder4 Disable lt gt lt gt le lt gt lt KIRKIKIKI x inch Reminder5 Disable User Email User Name Setup Google Health Profile Password Change Password Personal Data You can enter your personal data such as your gender height weight and age in the User Data section of the User Profile screen Changing Your Account Password To change your account password in the MDMouse application click User gt User Profile and click Change Password to display the Password screen that is similar to the Login screen Type a new password in the fields and click OK The new password applies the next time you log into the MDMouse application Note If you have forgotten your login password click New User in the Login screen to create a new account Once you are logged in using the new user account you can delete the old account whose password you have forgotten refer to Deleting a User Account Automatic Reminder In the User Profile screen you can configure reminders to notify you to measure your blood pressure Under Automatic Reminder select a time for each reminder You can specify up to five re minders When the time is reached a pop up notification screen PN MDMouse Blood Pressure Measurement Tool A Hello Cindy MDMouse remind you to measure your blood pressure displays in the MDMouse application Note
6. 3 5 3 7 cm 8 8 cm OR UNE temperature hu 10 40 C 50 104 F 30 85 R H midity eee temperature hu 10 40 C 50 104 F 15 90 R H midity Data transmission Connection to PC Using USB cable Power source PC USB DC 5V 500mA detection Dimension 125 L X65 W X46 H mm Weight 158 g If your blood pressure measurement value is beyond the range of the device SYS N DIA 55 200mmHg the device will display a message that recommends you consult a doctor 25 MDMouse User Manual Model MD 100 Software and Product Update Any updated information or software download will be posted in our web site at www mdmouse com Please check periodically for any news or updates About Us The MDMouse monitor was developed by CalHealth Inc in California and manufactured in China CalHealth Inc 10620 Treena Street Suite 230 San Diego CA 92131 www mdmouse com nd Ya Horng Electronic Co LTD No 35 Shalun Anding District Tainan Taiwan Factory Atten Electronic Dongguan Co Ltd 26 MDMouse User Manual Model MD 100 Warranty CalHealth warrants your MDMouse MD 100 blood pressure monitor against defects in mate rial or workmanship for a period of one 1 year after date of purchase Who is Covered You must have proof of purchase to receive warranty service A receipt or other document showing that you acquired the MDMouse product is considered proof of purchase THIS LIMITED WARRANTY EXT
7. Starting a measurement The inflatable cuff doesn t de flate after a measurement Measurements seem erratic or vary significant ly from meas urement to measurement 1 Stop and restart the MDMouse application and try again 2 Disconnect the MDMouse USB cable and reconnect 1 Stop and restart the MDMouse application and try again 2 Disconnect the MDMouse USB cable and reconnect It is common to see some variation since blood pressure changes throughout the day and from day to day Take several measurements over a 10 15 minute period to see if they are consistent If not 1 Ensure the finger cuff is positioned all the way down the base of your left index finger 2 Make sure the cuff is snugly tightened on your left index finger every time you take a measurement 3 Hold the monitor near heart level in the same posi tion each time you take a measurement 4 Keep your finger during a measurement slight movements can affect the measurement accuracy 5 Stay still and don t talk while measuring BP 23 MDMouse User Manual Model MD 100 Error Messages You may encounter one of the following error messages when using the MDMouse monitor If so please see the following description and follow the onscreen directions Error Message Malfunction Please Measure Again Communication Er ror Reconnect MDMouse Inlfation Malfunction Please Measure Again Deflation Malfunc tion Please Meas
8. is a registered trademark of CalHealth Inc Windows is a registered trademark of Microsoft Corporation MDMouse User Manual Model MD 100 Table of Contents Understanding Blood PreSsSure sesessesesessesessesessesescesescesescesescesescesecossesessesessesessesessesesseseeee 7 What is DIOOd Presse nes TE EE AAE EAEE ARS 7 What constitutes a high blood Pressure cccccccccsscccccsseccccsececcesececausececauneceeeeeceesausecesauneceseueeeesees 7 How can I tell how high my blood pressure IS csscccccsesecccceseccccensececausececcusececcuecceeeuseceesunecetseneceetaneeeets 7 CHANGEeS IB DOG FE CS U ee ee 7 Installing the Software and Mouse cccsccscscccsccsccccccccscsccccecscsccscecscnccscccscncescecscncesescecncesess 8 Making a Blood Pressure Measurement ssesessesescesescssescssesossesoscesescesessesessesessesescesessesecee 11 Start the MID O USE APPICCIU ON ee 11 Taking a Blood Pressure Measurement ccccccccesecccueccceuecccecsccuecsceuccsceueceeeueeseuneeseuaceeeueceeeneceueneeeeeneees 12 Exploring the MDMouse Capabilities scsscsssoscsssccscsceccccscnccscccscncescccscncesccscncescsscncesess 14 About the Application Screen nenne 14 Selecting d Display LONGUGGE uninteressant 14 User Account Monga e meN einen een een 15 Switching to a Different User Account 15 Creating a New User ACCOUNL cccscceeccsccceccseccuccseceuccseccuccseceuctseceuecseceueeseceuenseceneeseceseesecesetee
9. stored on your computer click Browse to locate the file If the video file is from a Web site specify the Web site URL in the field provided Click OK to save the changes and close the screen Note When selecting files from your computer select All files file type to view all files in the Open screen If you select an HTML file that includes a JPG or JPEG graphic file the graphic will not be displayed properly in the MDMouse application Starting and Storing a Measurement 1 After you have applied the finger cuff log into the MDMouse application 2 Press Enter on the keyboard or click the Start button in any screen The cuff begins to inflate and the increasing cuff pressure is indicated on the screen 18 MDMouse User Manual Model MD 100 3 You should see the animation on the screen and the music playing if the speaker sound is turned on After the cuff reaches the maximum the pump stops and the cuff begin to deflate The system starts to take your measurement a You can stop the measure at any time by pressing the Enter key again on the keyboard The cuff automatically starts to deflate 4 The measurement may take up to 70 seconds You can view the results from the View gt View Log screen Results shown are color coded based on the WHO ISH classification Sending Measurements Using Email Follow the steps below can send selected blood pressure measurements stored on your com puter through email 1 O
10. visit our website www mdmouse com support and register your monitor after purchase Product registration is not required for warranty coverage Product registration does not eliminate the need for the consumer to maintain the original proof of purchase in order to obtain warranty benefits In the event that you do not have proof of purchase date the purchase date for purposes of warranty will be the date the product was manufactured Requesting Repair Service Before requesting repair please check the troubleshooting section of this user manual If you are still unable to resolve the problem and wish to request warranty service you may con tact CalHealth at support mdmouse com Please describe the nature of your problem in your email Inthe event that product return is needed you will be provided a Return Ma terial Authorization RMA number and will be directed where you may send your MDMouse product for repair 28 MDMouse User Manual Model MD 100 Reference to Standards This device complies with the following normative documents COUNCIL DIRECTIVE 93 42 EEC of 14 June 1993 concerning medical devices as amended by Directive 2007 47 EC EN ISO 13485 2003 AC 2009 Medical devices Quality management systems Requirements for reg ulatory purposes ISO 13485 2003 Reference to standards contd EN 1S014971 2012 Medical devices Application of risk management to medical devices ISO 14971 2007 Corrected version 2007 10 01
11. E E A E A EE AE T A A A T 26 N a E EE E EE 27 Kerrem TO SION a T 29 PER EEEE E E E Er 30 MDMouse User Manual Model MD 100 Understanding Blood Pressure What is blood pressure The heart creates a force as it pushes blood into the arteries 117 and through the blood circulation system The arteries create mm Hg another force as they resist the blood flow Blood pressure is the result of these two forces The more blood your heart N Diastolic Reading pumps and the narrower your arteries the higher your blood Read as 117 over 80 pressure Blood pressure is expressed by two numbers which show your Systolic pressure the higher number when the heart is pumping out blood and Diastolic pressure the lower number when the heart is at rest between beats Guidelines per World Health Organization Severe Hypertension What constitutes a high blood pressure According to the Joint National Committee 7 JNC 7 definitions when systolic blood pressure exceeds 140 mmHg or diastolic High Normal blood pressure exceeds 90 mmHg this constitutes high blood pressure see figure below Optimal Diastolic 80 85 90 100 110 How can I tell how high my blood pressure is The MDMouse application displays measurement results including systolic blood pressure di astolic blood pressure and pulse based on the Joint National Committee 7 JNC 7 classification of blood pressure levels The color coded disp
12. ENDS ONLY TO THE ORIGINAL CONSUMER ACQUIRER OR ANY PER SON RECEIVING THE MDMOUSE PRODUCT AS A GIFT FROM THE ORIGINAL CONSUMER AC QUIRER AND TO NO OTHER ACQUIRER OR TRANSFEREE THIS WARRANTY DOES NOT EX TEND TO COMMERCIAL USERS This warranty applies only for product purchased and used in the United States MDMouse product offered in countries other than the United States may or may not be covered under warranty offered by the product distributor in your country Please contact that distributor for further information on warranty coverage in that country What is Covered Warranty coverage begins the day you acquire the MDMouse product From one 1 year from the acquisition date at the option of CalHealth the MDMouse product will be repaired or replaced with a new repaired refurbished or comparable product whichever is deemed necessary if it becomes defective or inoperative This exchange is done without charge to you for parts and labor You will be responsible for the cost of shipping to a location designated by CalHealth CalHealth will be responsible for the costs of shipping the replacement product to you If CalHealth cannot reasonably re pair or replace the MDMouse product then CalHealth may at is sole discretion refund the price you paid for the product All products including replacement products are covered only for the original warranty pe riod When the warranty on the original product expires the warranty on the repl
13. User Cindy Selecting a Display Language MDMouse Blood Pressure Measurement Tool File View Tools View Log User DataStorage Help Inthe MDMouse application you can select your own lan guage instead of the using the default English Start the MDMouse application click View gt Language and select your View Inquiry English Chinese Simplified language from the list The MDMouse application restarts Chinese Traditional French automatically and displays in your selected language You do fein Italian not have to re log in again ee Korean Spanish 14 MDMouse User Manual Model MD 100 User Account Management This section shows you how to create or delete user accounts and configure a user profile If more than one person is going to use the MDMouse monitor to measure their blood pressure each user should set up their own account Note If multiple people use the same user account the measurement history will consist of data from the different users making this data useless Switching to a Different User Account MDMouse Blood Pressure Measurement Tool After you have logged in the MDMouse application you can al me we To er mens EI ways switch to another user account From the main menu click nibs User gt Select User and select the user account you want to use ae A screen similar to the login screen displays Enter the password for
14. acement product also expires After one 1 year from the date of purchase you pay for the re placement of all parts and for all labor charges SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO ABOVE LIMITATIONS MAY NOT APPLY TO YOU What is Excluded Your MDMouse warranty does NOT cover 27 MDMouse User Manual Model MD 100 e Product replacement because of misuse accident lightning damage unauthorized repair or other cause not within the control of CalHealth e Incidental or consequential damages resulting from the product SOME STATES DO NOT ALLOW EXCLUSION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU e Any modifications or changes to the product including but not limited to software or hardware modification in any way other than as expressly authorized by CalHealth will void this limited warranty Except in the case of hardware or soft ware provided by CalHealth installing software modifications hacks or using ser vice access or back doors will void this limited warranty e A product used for commercial or institutional purposes Keep Your Documentation Please keep your receipt or other document showing proof of purchase Attach it to the Quick Start user guide provided with your MDMouse product Itis also recommended that you keep the original box and packing material in case you need to return your product We also recommend that you
15. ctions on www nomoreclipboard com to create a user account Note Select a Data Storage option to configure where you want to store your blood pressure measurements 17 MDMouse User Manual Model MD 100 Options MDMouse Options You can use the Options screen click Tools gt Zn Options to enable or disable MDMouse tutorial Do not show tutorial video at startup at start up and select a video for the default intial Display MDMouse application display during blood IE HER he fm Loc Mach pressure measure and or after blood pressure Zu measurement URL From Video File from Local Machine After Measurement Display URL From Video File from Local Machine Activating or De activating MDMouse Tutorial at Start up By default when you start the MDMouse application the MDMouse tutorial video plays You can disable MDMouse tutorial at start up in the start up screen or in the Options screen Select Do not show tutorial video at startup to disable the tutorial To enable it again clear the check box Click OK to save the settings and close the screen Selecting a Video Clip You can select your own video clip to play as the initial screen during blood pressure meas urement and or after blood pressure measurement The MDMouse application supports HTML AVI and WMV file formats In the Options screen select the type and location of the video file from the URL From drop down list If the video file is
16. dition 2003 15 Microsoft Licer Mode Driver Framework Feature Pack 1 0 J Microsoft visual C 2005 Recktrbutable Currently installed programs D show updates ID Opening AAC Add on Module 1 0 00 JB Opening Limited Patch 4 5 05 05 12 01 IB Opening Secure Module 4 5 01 JB POF Manual NW S200 Series E Powers Gear QuickTime O ReaPiryer 5 Reakek High Definition Audo Driver Wd RoboHelp Office x5 1 RoboSource Conkrol re Silicon Laboratories CP2 10x USB to UART Bridge Driver Removal To change this program or remove R from your computer cick hanga Remove GB Iypem 3 6 D Soniestage 4 0 Synaptics Pointing Device Driver PD Trend Mero OfficeScan Client Trend Moro Threat Management Agent Mme X Silicon Laboratories CP210x USB to UART Bridge Driver Unins Silicon Laboratories Silicon Laboratories CP210x USB to UART Bridge Installation Location Driver Yersion 5 3 c Program Files Silabs MCU CP21 0x5 i Cancel MDMouse User Manual Model MD 100 Care of Your MDMouse Monitor Your MDMouse blood pressure monitor requires no maintenance and simple care to keep it clean Dirt or smudges on the MDMouse are easily cleaned with a lightly dampened cloth Do not use chemical cleaners as they could damage the bladder or components Clean the device with a soft damp cloth The dirt on the cuff can be cleaned by the moisten cloth and soap Do not flush the device and cuff with water Do not bend o
17. e by connecting the USB connector to an available USB port on your com puter P You re done Now let s take a blood pressure measurement 10 MDMouse User Manual Model MD 100 Making a Blood Pressure Measurement Start the MDMouse Application 1 To log into the MDMouse application click the MDMouse application on your desktop Tip You can use the login screen to MDMouse create new user accounts If you Blood Pressure have forgotten your account pass d ei word you can also use the login screen to create your account again 2 For your first login attempt enter a user name and password to create a new account then click OK to log in New User Password Cancel CalHealth Inc 3 The animated MDMouse tutorial starts It is recommended that you complete the tutorial before using your MDMouse Note You can choose to stop playing this tutorial every time you log into the MDMouse application 11 MDMouse User Manual Model MD 100 Taking a Blood Pressure Measurement Before taking a reading you should sit quietly for around 10 minutes and there should be an interval of at least 5 minutes between readings While taking a measurement you should stay calm and relaxed and try not to talk This will improve the accuracy of the readings Follow the instructions below to take a blood pressure measurement l Liftthe protective cover from the mouse and flip the finger cuff out Flip the
18. e innovative MDMouse blood pressure monitor High blood pressure is a significant contributor to serious diseases such as heart attack and stroke but it is largely controllable with knowledge lifestyle and diet and working with your physician Regular monitoring will provide you and your physician with the knowledge needed to decrease your risk of disease Use the MDMouse monitor as your normal computer mouse and you will always have a handy blood pressure monitor right at your fingertips making it easy to quickly track of your blood pressure a great step towards staying healthy The following instructions will guide you through installation and how to take a blood pressure measurement set user profiles review your history and transfer your data history to your phy sician You can also find more information in the Help section of the MDMouse application or learn more on our website at www mdmouse com Also please register your new MDMouse monitor to receive any updates or future information You can do this on our website at www mdmouse com support Disclaimer Information in this guide may change without notice The manufacturer assumes no responsi bilities for errors that may appear in this guide Copyright 2013 CalHealth Inc All rights reserved No part of this publication may be repro duced photocopied stored in a retrieval system or transmitted without prior written consent of CalHealth Inc MDMouse
19. lays provide a convenient way of gauging the condition of your blood pressure N Itis recommended that you consult a physician to fully understand blood pressure levels Changes in Blood Pressure A person s blood pressure is constantly changing Blood pressure can fluctuate considerably through the course of a single day and it is also affected by the seasons and by the weather One or two readings are not sufficient to get an accurate picture of your blood pressure Ideally you should get into the habit of checking your blood pressure at fixed time several times a day every day and keep a detailed record of these readings This record can then be e mailed or faxed to your doctor helping you to monitor your health on an ongoing basis A normal healthy person s blood pressure fluctuates within a range of approximately 10 mmHg MDMouse User Manual Model MD 100 Installing the Software and Mouse Follow the steps below to install the MDMouse application and driver on your computer to use the built in blood pressure monitor 1 Insert the software CD into the CD ROM drive on x The following components will be installed on your machine your computer The CD should auto run other wise locate and double click setup exe If you are prompted to install Visual C runtime librar Do you wish to install these components ies click Install If you choose Cancel setup will exit Install Canco Visual C Runtime Libraries x86
20. mMdemouse MD 100 Blood Pressure Monitor User Guide MDMouse User Manual Model MD 100 Intended Use The MDMouse blood pressure monitor is a noninvasive blood pressure measurement system intended to measure the systolic and diastolic blood pressures and pulse rate of an adult indi vidual over age 18 at home by using a non invasive technique in which an inflatable cuff is wrapped around the left index finger The cuff circumference is designed to fit adult Left In dex Fingers from 1 5 to 3 5 inches 3 7 8 8 cm in circumference AN Caution This device is not intended to be a diagnostic device Self diagnosis and self treatment are dangerous Contact your physician if you observe values indicating hypertension People with severe blood flow problems or disorders should consult their physician prior to using any blood pressure monitoring device as cuff inflation can cause damage or in ternal bleeding Do not take measurements right after drinking alcohol smoking exercise or eating as those activities may distort the results Performance can be affected by a number of health factors including age diabetes common arrhythmias ventricular premature beats atrial fibrillation arterial sclerosis and pregnancy This unit will not serve as a cure for any symptoms of your heart or disease The meas urement result is only for reference Always consult your physician if any measuring re sults are to be interpreted Always foll
21. n the Display panel select the display format Table or Chart To search and display a log select a date from the From and To drop down list boxes The screen can display the results of the three most recent measurements Results shown are col or coded based on the WHOJ ISH classification Printing Logs To print the queried logs click File gt Print You can also display a print preview of the logs be fore printing click File gt Print Preview 20 MDMouse User Manual Model MD 100 Uninstalling the MDMouse Application If you need to remove the MDMouse application from your computer use the following steps 1 Display the Control Panel screen click Start gt Settings gt Control Panel 2 Click Start gt Programs gt MDMouse Add or Remove Programs then select Uninstall MDMouse and click Remove The uninstalla tion screen displays Click Next 3 A prompt screen displays Click Yes to All to delete all related system files to remove the MDMouse application 4 Inthe Add or Remove Programs screen se lect Silicon Laboratories CP210x USB to UART Bridge Controller Driver Removal and click Change Remove 5 When a prompt screen displays click Unin stall to continue 6 After device driver uninstall is complete you may need to restart your computer Click Yes to restart 21 Add or Remove Programs AD ripe Networks Network Connect 6 0 0 JB Marumads Shocemane Mayer rosaft Office Professional E
22. nced radio TV technician for help You are cautioned that changes or modifications not expressly approved by the party respon sible for compliance could void the user s authority to operate the equipment 30 MDMouse User Manual Model MD 100 MOemouse CalHealth Inc 10620 Treena Street Suite 230 San Diego CA 92131 www mdmouse com 31
23. ow the operation procedures described in this manual to measure your blood pressure correctly Do not use the MDMouse to measure blood pressure on infants or children it is OK to use as a normal computer mouse Do not use the unit on infants or persons who cannot express one s intention Do not inflate the cuff without being wrapped on an index finger Do not drop the MDMouse Safeguard the unit from strong impact Measurement may be inaccurate if the device is used close to a television microwave oven mobile phone X ray or other devices with strong electrical field Do not attempt to service the unit yourself please refer to an authorized repair facility if your MDMouse system needs repair Be sure to store this manual for future reference MDMouse User Manual Model MD 100 Requirements Your MDMouse monitor requires the following to use Windows based Personal Computer with available USB port CD ROM drive to install software or internet connection to download software if you don t have a CD ROM drive Internet connection to email data or update online data records Included in Package 1MDMouse blood pressure monitor 1 Quick Start User Guide E 1 CD ROM with MDMouse application software Mdemnouse Model MD 100 Blood Pressure Monitor Quick Start User Guide en gt Sverre gt MDMouse User Manual Model MD 100 A Great Step to a Healthier Life Thank you for choosing th
24. pen the MDMouse application and click View gt View Log 2 Select one or more blood pressure measurements you want to send over email 3 Click Tools gt Email Measurement A new email screen displays with the selected meas urements in ASCII format 4 Enter the sender email and your message if required before you send the email Deleting Measurements The MDMouse application gives you the option to delete one or all blood pressure measure ments stored on your computer To delete a blood pressure measurement stored on your computer click Tools gt Delete Meas urement select a measurement and click Delete To delete all blood pressure measurements stored on your computer click Tools gt Delete All Measurements A screen displays prompting you to confirm the deletion Click OK to delete 19 MDMouse User Manual Model MD 100 Using Data Logs To view blood pressure measurements stored on your computer click View gt View Logs The log screen displays listing the stored measurements by date You can send selected logs through email refer to Sending Measurements Using Email for information Log Inquiry and Analysis You can search logs by date and display the information in a table or chart Click View gt View ing Inquiry to display the Inquiry amp Analysis screen q MDMouse Blood Pressure Measurement Tool Nes File View Tools User DataStorage Help Sunday May 10 2009 m Saturday May 16 2009 m I
25. pro tective cover back closed 2 Slide your left index finger all the way into the cuff so that the cuff is on the lowest part of your finger 3 Hold your finger against the MDMouse so that the inside of your finger is laying along the side of the MDMouse 4 Tighten the finger ring for the suitable finger size position It should feel snug on your finger but not so tight that it restricts blood flow 5 Locate the bottom of your sternum this is the level you ll want to hold the MDMouse while taking a measurement This places the MDMouse at the same level as your heart helping improve the consistency and accuracy of the meas urement 12 MDMouse User Manual Model MD 100 6 Place the MDMouse at your sternum and click Enter on your keyboard to begin a measurement 7 During a blood pressure measurement support your left arm by resting your el bow on a table or holding it with your other arm to help reduce the muscle tension in your arm which can affect accuracy 8 Note If your finger feels cold please warm it up before measuring your blood pressure as cold temperature can affect accuracy Please make sure the room temperature will not be below 50 degree Fahrenheit or 10 degree centigrade During the measurement process you will hear the inflation pump in the MDMouse activate and will feel the cuff pressure on your finger Atypical measurement takes approximately 35 45 seconds If at any time during this process yo
26. r fold the cuff E Donot place a sharp or pointed object again the cuff Doing so may scratch or cut the cuff and damage the air bag Do not dismantle the device or disconnect the cuff or try to repair by yourself If any problem happens refer to the distributor Do not operate the device under the severe environment of extreme temperature or humidity or direct sunshine Do not shake the unit violently E Do not use an alcoholic base or solvent agent to clean the device E Do not inflate the inflatable cuff without a finger inserted inside the cuff Clean with a lightly dampened cloth don t use chemical cleaners Do not bend or fold the cuff or use sharp objects on the cuff which could damage the air bladder Disposal pd This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sus tainable reuse of material resources To return your used device please use the re turn and collection systems or contact the retailer where the product was purchased They can take this product for environmentally safe recycling 22 MDMouse User Manual Model MD 100 Troubleshooting If you are experiencing problems with the MDMouse monitor please check the following Problem Try This The inflatable finger cuff does not inflate after
27. risk management process ISO 10993 1 2009 ANSI AAMI SP10 2002 A1 2003 R 2008 Manual electronic or automated sohygmomanometers ANSI AAMI ISO 81060 1 2007 ANSI AAMI IEC 80601 2 30 2009 ANSI AAMI ISO 81060 2 2009 Non invasive sohygmomanometers Part 2 Clinical validation of automated measurement type 29 MDMouse User Manual Model MD 100 FCC Statement POTENTIAL FOR RADIO TELEVISION INTERFERENCE for USA only This product has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the ins tructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by tur ning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the re ceiver is connected e Consult the dealer or an experie
28. seueeseceneseeees 15 Pee NO U SEF ACC HUN ee been meer 15 Sano 1 ee EEE A 16 Per ona D A E E E E E E E E 16 Chanana Your Account POSS ONO seen S EEE ee ee 16 Anona FETUNG GP see E E E tear tear eienmcteuadiaaceacentaes 16 Data Management and Personal Health RecordS sessesescssesessesessesessesessesessesescesessesescesesee 17 DIT OI e E E E EE ee A 17 NOMOFe GODO ee Eee 17 E E ET 18 Activating or De activating MDMouse Tutorial at Start up ccccccceseccceeeccccescceecseeececeeceeeeeeeeneeeees 18 SEIELLNGO V O E 18 Starting ONG Storing g Measurement nern een 18 Sending Measurements Using Email cccccccccccccuseccccvecccuecccunccccuecsceecsceuecseeueeeeuuceseecsseueceteueceneneseueneees 19 DOLCE Measurement S serere Aen narn E EE E A EE EA 19 e DAN E E E E EE E A ETE E 20 MDMouse User Manual Model MD 100 Log TAGUITY and Analysis zueinander ur 20 PIC INO OOS ne a E 20 Uninstalling the MDMouse Application ccccccccsssssscscscesccscsccscccscnccscccscncesccscncescscscncesess 21 Care of Your MDMouse MONItOT ccsssssccsccccccsccsccsccecccsscsscsccescssssssceccescsssessceccessessesccesoosss 22 TOUNO DOO PSRPEETETERIENEERRUENEERELUEUTERTEUELLETEEEIENEERUEETERTEUEUNERTRETELTREECHTEREORUERTERFERFOREETERERUERENENER 23 EOF DIES gt e E EE E E EE E E ES 24 Pt Ma seas nE a E S AN a a 25 Software and Product Update sesessesessesessesescesescesesoesessesessesescesesoesesossesesoesossesessesessesesses 26 PS PER
29. the user account and click OK to switch Creating a New User Account There are two ways to create a new user account The first method is to create a new user account using the login screen When you start the MDMouse application the login screen dis d Health displays simply enter a new user name and password to create ae a new account and log in at the same time Alternatively you can click User gt Add User in the MDMouse application to display the login screen Enter a new user name and password and click OK eso be Deleting a User Account To delete a user account click User gt Remove User from the main menu and click the user name you want to delete A warning screen displays prompting you to confirm the deletion Once you delete an ac count all related data is also removed MDMouse Blood Pressure Measurement Tool 2 j Are you sure you want to remove user test All data belongs to user test will also be removed 15 MDMouse User Manual Model MD 100 User Profiles You can use the User Profile screen click User gt User Profile to configure the following set tings User Profile Current User Cindy e Personal data such as gender weight and so on een es Reminder 09 30 Gender e Blood pressure measurement alarms T e NoMore Clipboard _ e Change your login password Google Health Normore Clipboard Reminder2 22 00
30. u need to stop the measurement hit En ter again on your computer keyboard and the cuff will deflate After you have finished measuring loosen the finger cuff by with the rotating finger ring Re move your finger and rotate the cuff back inside the MDMouse into its original position and close the protective cover 13 MDMouse User Manual Model MD 100 Exploring the MDMouse Capabilities Although it is simple and quick to begin using the MDMouse blood pressure monitor there are other features and capabilities you may wish to use You can change the display language set up user profiles and manage how you store your data or how to send it to your physician About the Application Screen The MDMouse application screen consists of the following elements Navigation Panel Use to navigate to a configuration screen or view logs and online help contents Settings and Display Area This area displays settings logs or BP measurements Start Click Enter when you are ready to start your BP measurement Status Panel This panel displays the current user account Z MDMouse Blood Pressure Measurement Tool A ile View Tools User DataStorage Help Category Classification Level Severe gt 180 derate 160 179 i Systote u Cu 140 159 Sys N WHOASH en ee hypertension 130 139 ht s120 spat 10 0 al B B TE 100 109 High normal BP 90 99 Normal BP o 8589 Optimal BP Diastolic c D urrent
31. ure Again Finger Ring Too Loose Readjust and Measure Again Finger Ring Too Tight Readjust and Measure Again Data Invalid Please Measure Again Description A problem occurred when during operation If the problem persists try disconnecting and reconnecting the MDMouse and try again A data communication error between the MDMouse and your PC has occurred Disconnect the USB cable and recon nect A problem occurred when inflating the finger cuff Readjust the cuff and try measuring again Keep your finger still since movement can affect measurements A problem occurred while deflating the finger cuff Readjust the cuff and try measuring again Keep your finger still since even slight movements can affect measurements Readjust the finger cuff and measure again Make sure the cuff is snugly tightened at the base of the left index finger Readjust the finger cuff and measure again The cuff should feel snug on the finger but not so tight it is restrict ing blood flow The collected data appeared to have a problem The most common cause is movement of the finger during measure ment Readjust the finger cuff and measure again 24 MDMouse User Manual Model MD 100 Product Specification Measuring method Oscillometric method Measuring range Pressure 55 200 mmHg Pulse rate 40 200 pulses min Pressure 3 mmH Pulse 5 of reading value Cuff specification Designed for Left Index Finger circumference 1 5