Home

K3HB-R - Digi-Key

image

Contents

1. For KSHB series DeviceNet models use only the DeviceNet Connector included with the product The crimp terminals provided are for Thin Cables O N OMRON K3HB R E Characteristics Display range 19 999 to 99 999 Measurement accuracy Functions F1 F6 0 006 rgd 1 digit for voltage pulse open collector sensors at 23 5 C Functions F2 to F5 0 02 rgd 1 digit for voltage pulse open collector sensors Measurement range Functions F1 to F6 0 5 mHz to 50 kHz for voltage pulse open collector sensors Input signals Contact input dry contact input 30 Hz max with ON OFF pulse width of 15 ms min No contact voltage pulse 50 KHz max with ON OFF pulse width of 9 us min ON voltage 4 5 to 30 V OFF voltage 30 to 2 V input impedance 10 kQ Open collector 50 KHz max with ON OFF pulse width of 9 us min Connectable sensors ON residual voltage 3 V max OFF leakage current 1 5 mA max Load current Must have a switching capacity of 20 mA or higher Must be able to properly switch load currents of 5 mA or less Comparative output response Functions F1 to F6 100 ms max time until the comparative output is made when there is a forced sudden time transistor output change in the input signal from 15 to 95 or 95 to 15 Linear output response time Functions F1 to F6 110 ms max time until the final analog output value is reached when there is a forced sudden change in the input signal from 15 to 95 or 95
2. K3HB R P C Digital Indicator User s Manual Cat No N136 The manual can be downloaded from the following site in PDF format OMRON Industrial Web http www fa omron co jp K3HB R E Component Names and Functions Max Min status indicator Turns ON when the maximum value or minimum value is displayed in the RUN level Level bank display In RUN level displays the bank if the bank function is ON Turns OFF if the bank function is OFF In other levels displays the current level PV display Displays PVs maximum values minimum values parameter names and error names Displays the position of the PV with respect to a desired scale Comparative output status indicators Display the status of comparative outputs SV display Displays SV and monitor values Status indicators SV display status indicators i ications writing Indicator Function Lit when communications writing is ON enabled and not lit when OFF prohibited Turns ON when parameters for which T teaching can be performed are Turns ON OFF when HOLD input turns displayed ON OFF HH H In RUN level turn ON when the comparative set value HH H L or LL L LL is displayed MAX MIN Key LEVEL Key MODE Key SHIFT Key UP Key Used to switch the Used to switch level Used to switch the Used to change When changing a set display between the PV parameters displayed parameter settings value this key is used maximum
3. OVER and DATA VALID can be used in a wired OR DATA 1 es ccs aes 3 RUN HH H PASS L and LL are always output with or without a REQUEST signal DATA Do not used a wired OR VALID z m INT connect for these signals See note See note See note Note Leave 20 ms min between DATA VALID turning OFF and the REQUEST signal Programmable Controller Connection Example Display Unit Connection Example Digital Indicator SYSMAC Programmable Controller Digital Indicator Connector pin No See note DC Input Unit Connector pin No See note a T i 4 1 COMMON COM 4 1 COMMON Co el D ol aem 3 0 IN Internal circuit Lies DATA VALID des RUN 40O On aT jA COMMON all Transistor Output Unit Tas eee 5V CI DF 240 0 Hz O O ft Oo e _ Tek UST le CT 4 240 Q ia tat CED oS rR 31 POLARITY COM r a rm a k m poari f o o 4 SEC 24 VDC X L______ M7E 01DOn2 01HON2 D424 V lt M7E Digital Display Unit gt DC power Note The BCD output connector pin number is the D sub connector pin number when Cov supply the BCD Output Cable sold separately is connected This number differs from the pin number for the Digital Indicator narrow pitch connector manufactured by Honda Tsushin Kogyo Co Ltd Refer to the following User s Manual for application precautions and other information required when using the Digital Indicator
4. Transistor output J E E es E E 7 Drive Event input C circuit E Relay output DeviceNet Safa Linear output Q circuit Communi cations Communications K driver Sensor power supply circuit Power supply OMRON K3HB R E BCD Output Timing Chart A REQUEST signal from a Programmable Controller or other external device is required to read BCD data Single Sampling Data Output Continuous Data Output 20 ms pulse min 50 ms max REQ wT OOOO REQ MAX MIN MAX MIN DATA All data High DATA All data High All data High DATA DATA VALID Approx 24 ms B a 40 ms 30 ms 64 ms 64 ms ms 16 ms The data is set in approximately 30 ms from the rising edge of the Measurement data is output every 64 ms while the REQUEST signal REQUEST signal and the DATA VALID signal is output remains ON When reading the data from a Programmable Controller start reading the data when the DATA VALID signal turns ON The DATA VALID signal will turn OFF 40 ms later and the data will turn OFF 16 ms after that Note If HOLD is executed when switching between data 1 and data 2 either data 1 or data 2 is output depending on the timing of the hold signal The data will not go LOW e The K3HB BCD output model has an open collector output so wired OR connection is possible REQ 1 Programmable Controller REQ a DATA including POL and
5. an accurate rotation speed rpm can be calculated The actual setting is X 2 0000 mantissa and Y 107 exponent OMRON K3HB R E What Is the Auto zero Function Set this function before using the Digital Indicator If a function to F is set the frequency can be force set to zero if there is no input pulse for a set period This period is called the auto zero time Set the auto zero time to slightly longer than the longest input pulse interval The display will not easily return to zero if the auto zero time is too long or left at the default setting Time Unit Settings SEAR Prescale value menu setting ASS mm ss d display d tenths of a second Note Time unit can be set only when passing time F6 is selected Input Type Setting NO Voltage pulse high NC Voltage pulse low No contact or voltage pulse input Contact e S O O Note Setto ii or i when there is a large variation in the display The largest measurement range is 30 Hz K3HB R Common Specifications E Event Input Ratings K3HB R S TMR HOLD RESET BANK1 BANK2 BANK4 ON 1 kQ max OFF 100 kQ min ON residual voltage 2 V max OFF leakage current 0 1 mA max Load current 4 mA max Maximum applied voltage 30 VDC max E Output Ratings Contact Output Transistor Outputs Resistive loads Inductive loads Maximum volt 24 VD 250 VAC coso 1 250 VAC closed 2 um 10an VOtAge 30 VDC L R 0 m
6. displayed as any value Comparative Set Value Display RIFF betas Select whether or not to display the comparative value during operation Display auto return r Ek Automatically returns the display to RUN level when there are no key operations e g max min switching bank settings using keys Other Max Min Hold Holds the maximum and minimum measurement values baH E Switch between 8 comparative value banks using the keys on the front panel or external inputs A set of set comparative values can be selected as a group Bank Copy LaPy Any bank settings can be copied to all banks Bank Selection To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multipl In the interest of product improvement specifications are subject to change without notice OMRON Read and Understand This Catalog Please read and understand this catalog before purchasing the products Please consult your OMRON representative if you have any questions or comments Warranty and Limitations of Liability WARRANTY OMRON s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year or other period if specified from date of sale by OMRON OMRON MAKES NO WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED REGARDING NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER
7. e Circumferential speed Roll circumference x Rotation speed rpm Flow rate ratio F5 e Passing time Length of processing stage These calculations are automatically made internally and displayed whenever any input pulse is received Measures frequency for input A and displays the Measuring roller winding speed Measuring motor speed i rotation rpm or circumferential speed proportional to for product testing circumfer the input frequency ential Display value D fa x 60 x a fa Input frequency Hz speed eres Calculation Display unit Prescale value 0 flowrate _ Rotation most j y i Frequency pulse Circumfer se m min nd N 0 06 nal Instanta Check the output neous in specifications of the input flowrate device and calculate the prescale value from the following equation Display value D fa x 60 x O N Pulses per rotation md Circumferential length per rotation m F2 B Absolute A by 100 and ratio displays the ratio as a percentage Display unit Multiples input B divided by input A Measuring the speed ratio between two rollers Warning OMRON K3HB R F3 Multiplies the error between input A and input B Measuring the line speed error ratio between two conveyors SORTAN 1 by 100 and displays the ratio as a percentage Display unit Communications output To computer remote monitoring F4 Displays the difference between input A
8. line 1 kV I O signal line Surge Immunity EN61000 4 5 1 kV with line power line 2 kV with ground power line Conducted Disturbance Immunity EN61000 4 6 3 V 0 15 to 80 MHz Power Frequency Magnetic Immunity EN61000 4 8 30 A m 50 Hz continuous time Voltage Dips and Interruptions Immunity EN61000 4 11 0 5 cycle 0 180 100 rated voltage OMRON K3HB R Operation E Functions Operating Modes F1 to F6 Functions F1 to F6 provide rpm circumferential speed and other calculation displays by measuring continuous pulses frequencies Example ene Length of f f processing stage F1 Displays rotation rpm or circumferential speed for one input e F2 to F5 Displays the calculation result for two rotation rom speeds of the processing stage for one input G To F6 Displays the passing time calculated from the circumferential speed and the length The basic principle used by the Digital Indicator to calculate the rotation speed rpm display is to count the ON OFF time T for input sensor or other device inputs using the internal system Functionname Function No clock and then automatically calculate the frequency This frequency f is multiplied by 60 and Rpm circumferential displayed as the rotation rpm speed speed Absolute ratio E Input sensor or other input pulse ON OFF time T a Frequency f gt mowo FS Rotational difference FY e Rotation speed rpm f x 60
9. to 15 Insulation resistance 20 MQ min at 500 VDC Dielectric strength 2 300 VAC for 1 min between external terminals and case Noise immunity 100 to 240 VAC models 1 500 V at power supply terminals in normal or common mode waveform with 1 ns rising edge and pulse width of 1 us 100 ns 24 VAC VDC models 1 500 V at power supply terminals in normal or common mode waveform with 1 ns rising edge and pulse width of 1 us 100 ns Frequency 10 to 55 Hz Acceleration 50 m s 10 sweeps of 5 min each in X Y and Z directions 150 m s 100 m s for relay outputs 3 times each in 3 axes 6 directions Weight appo SOO G BaseUnitonly OOS yy Degree of Front panel protection IPOO finger protection VDE0106 100 Memory protection EEPROM non volatile memory Number of rewrites 100 000 Applicable standards UL61010 1 CSA C22 2 No 1010 1 evaluated by UL EN61010 1 IEC61010 1 Pollution degree 2 Overvoltage category II EN61326 1997 A1 1998 A2 2001 EMC EMI EN61326 industrial applications Electromagnetic radiation interference CISPR 11 Group 1 Class A Terminal interference voltage CISPR 11 Group 1 Class A EMS EN61326 industrial applications Electrostatic Discharge Immunity EN61000 4 2 4 kV contact 8 kV in air Radiated Electromagnetic Field Immunity EN61000 4 3 10 V m 1 kHz sine wave amplitude modulation 80 MHz to 1 GHz 1 4 to 2 GHz Electrical Fast Transient Burst Noise Immunity EN61000 4 4 2 kV power
10. C 5 A resistive load oe Mechanical life expectancy 5 000 000 operations Electrical life expectancy 100 000 operations meinen Transistor output Maximum load voltage 24 VDC Maximum load current 50 mA Leakage current 100 uA max Linear output Linear output 0 to 20 mA DC 4 to 20 mA DC Load 500 Q max Resolution Approx 10 000 Output error 0 5 FS Linear output 0 to 5 VDC 1 to 5 VDC 0 to 10 VDC Load 5 kQ max Resolution Approx 10 000 Output error 0 5 FS 1 V or less 0 15 V no output for O V or less Display method Negative LCD backlit LED display 7 segment digital display Character height PV 14 2 mm green red SV 4 9 mm green Scaling function measurement operation selection averaging output hysteresis output OFF delay output test teaching display value selection display color selection key protection bank selection display refresh period max imum minimum hold reset Accessories Watertight packing 2 fixtures terminal cover unit stickers instruction manual DeviceNet models also include a De viceNet connector Hirose HR31 5 08P 5SC 01 and crimp terminals Hirose HR31 SC 121 See note 3 Note 1 DC power supply models require a control power supply capacity of approximately 1 A per Unit when power is turned ON Particular attention is required when using two or more DC power supply models The OMRON S8VS series DC Power Supply Unit is recommended PNP input types are also available
11. N open collector 2 8 inputs 10 pin MIL connector NPN open collector 3 5 inputs M3 terminal blocks PNP open collector 4 8 inputs 10 pin MIL connector PNP open collector Note 1 CPA can be combined with relay outputs only 2 Only one of the following can be used by each Digital Indicator RS 232C RS 485 communications BCD communications or DeviceNet communications Accessories Sold Separately Rubber Packing K32 DICN Special Cable for event inputs with 8 pin connector Po Model yY YO K32 BCD Special BCD Output Cable K32 P1 Note Rubber packing is provided with the Controller OMRON K3HB R Specifications E Ratings Supply voltage 100 to 240 VAC 24 VAC VDC DeviceNet power supply 24 VDC Allowable power supply voltage 85 to 110 of the rated power supply voltage DeviceNet power supply 11 to 25 VDC range Power consumption 100 to 240 VAC 18 VA max max load See note 1 24 VAC DC 11 VA 7 W max max load DeviceNet power supply 50 mA max 24 VDC Input No voltage contact voltage pulse open collector External power supply 12 VDC 10 80 mA models with external power supply only Event inputs Startup compen NPN open collector or no voltage contact signal See note 2 sation timer input ON residual voltage 2 V max ON current at 0 Q 4 mA max Reset t Max applied voltage 30 VDC max OFF leakage current 0 1 mA max Bank input Output ratings Relay output 250 VAC 30 VD
12. OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE OMRON DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED ON CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY REPAIR OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED STORED INSTALLED AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION ABUSE MISUSE OR INAPPROPRIATE MODIFICATION OR REPAIR Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combination of products in the customer s application or use of the products At the customer s request OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product machine system or other application or use The following are
13. Rotary Pulse Indicator K3HB R Digital Rotary Pulse Meter Capable of 50 kHz Measurements e Visual confirmation of judgement results through display colors that switch between red and green 1 e Measures High speed Pulses at 50 kHz Provides high speed pulse measurements up to 50 kHz of rotary encoder or ON OFF pulse signals and can perform rotating measurement of high speed rotating objects Note No voltage contacts of up to 30 Hz are supported e Six Measurement Operations Including Rotation rpm Circumferential Speed Ratio and Cumulative One Rotary Pulse Meter has 6 rotary pulse measurement functions to support a variety of pulse measurement applications Select the best function for your application from the following Rotation rpm circumferential soeed instantaneous flowrate value proportional to frequency absolute ratio error ratio error flow rate 4 D ratio and passing speed value inversely proportional to frequency cAi us e DeviceNet models added to the series 2 1 Visual confirmation of judgement results is not supported on models that do not have an output or models that do not support DeviceNet You can change the display color by setting it but you cannot switch it based on the judgement results 2 DeviceNet models have a depth of 97 mm Refer to Safety Precautions for All Digital Panel Meters Model Number Structure E Model Number Legend Base Units and Optional Boards can be ordered individua
14. and input B Measuring the rotation rpm circumferential speed error absolute error Rotational B A as the rotation rom speed error or between two conveyors difference circumferential speed error Display unit rpm rps rph Hz kHz mm s m s m min km h l min I h etc LL L Warning F5 Displays the flow rate ratio of B from inputs A and B Flow rate B ratio A B Display unit i Linear output ig Recording meter as a ratio F6 Passing by measuring the frequency of input A lime Passing time s 1 fa x Q fa Input frequency Hz Set the prescale value for the desired display unit using the following table for reference Display unit Prescale value o TEN N Pulses per rotation p md Circumferential length per rotation m L Length of process m Display unit Seconds s minutes min hours minutes seconds h min s minutes seconds tenths of seconds min s 1 10s etc OMRON E What Is Prescaling To make calculations using the input pulse to display rotation rpm or circumferential speed the number of pulses per rotation or the length of the circumference must be multiplied by a certain coefficient This coefficient is called the prescale value JS I _kaH8 R Proximity sensor Rotation speed rom f x 60xa f Input pulse frequency No of pulses per second a Prescale value If there are 5 pulses per rotation then a 1 5 0 2 2 x 10 and
15. eck the required power supply type B Sensor Power Supply Output Sensor power supply PASS output C Relays Transistors BCD and DeviceNet Relay Outputs Relay Outputs Transistor Outputs DeviceNet Connector Included lt C1 gt lt C2 gt lt T1 gt lt T2 gt PNP les a no 12 VDC H C H E 80 mA com 3 PASS lt CPA gt L C 1 V Power supply cable Black Sensor power supply linear output LL C3 2 CAN L Communications cable Blue 3 Shield COM C9 4 CAN H Communications cable White 0 5 1 5 5 V Power supply cable Red 0 10 V Applicable Connector HR31 5 08P 5SC 01 HIROSE ELECTRIC CO LTD N C Attach the provided crimp terminals BCD NPN Open Collector lt BCD gt Applicable Connector Sold separately 12 VDC K32 BCD OMRON 80 mA HDR E50MAG1 with 0 3 m cable REQUEST MAX REQ lt L2A gt lt L1A gt Sensor power supply The BCD COMMON is shared The pins indicated in the above diagram as blank white boxes have been removed COMMON Only one of the following can be used for each Digital Indicator communications BCD or DeviceNet Contact Outputs Transistor Outputs NPN Open Collector 12 VDC 80 mA Safety Standards Conformance RS 485 RS 232C lt FLK3A gt lt FLK1A gt e Always use a EN IEC compliant power supply with reinforced insulation or double insulation for the DeviceNet power supply e The product must be used indoors for t
16. ed by DDK Connector Equivalent to 17JE 13370 02 manufactured by DDK Stud 17L 002A manufactured by DDK Note The BCD Output Cable has a D sub plug Cover 17JE 37H 1A manufactured by DDK Connector equivalent to 17JE 23370 02 D1 manufactured by DDK Special Cable for Event Inputs with 8 pin Connector Model Appearance Wirin _ K32 DICN HOLD QQOQOQQQQQOOQO O OQO OOOHO QGOOQOOOOOOOOOOOOOE LL COMMON a OO Sa a 0 a N 0AN OAN OAN OANA Nh o 3 000 mm 3 m a Cable marking DOIN ODO oO OMRON K3HB R E Derating Curve for Sensor Power Supply Reference Values For 12V Maximum current mA 20 10 0 10 20 30 40 50 60 Ambient temperature C Note 1 The above values were obtained under test conditions with the standard mounting The derating curve will vary with the mounting conditions so be sure to adjust accordingly 2 Internal components may be deteriorated or damaged Do not use the Digital Indicator outside of the derating range i e do not use it in the area labeled above E internal Block Diagram Pulse input E circuit z Pulse input C EEPROM r Drive circuit a Waveform shaping circuit r Drive circuit BCD e Input circuit e Output circuit e Transistor output circuit Digital input circuit Linear output ie beat 6 circuit
17. he above applicable standards to apply OMRON NPN Input Model K3HB R PNP Input Model e NPN input section E3 E6 12V e Rotary Pulse Meter KSHB R COM NPN Input PNP Input K3HB LINB K3HB LIPB mS E 510 Q E2 E5 Voltage e Input A 1 N Input A PNP l 7 LO COM E3 com E9 E9 Input B PNP ES PN Ecom Ecom Note E3 and E6 as Note E3 and E6 as well as B6 well as B5 are are internally internally connected connected D Event Inputs Input B Voltage N e Use terminal pin D6 as the common terminal e Use NPN open collector or no voltage contacts for event input Models with Terminal Blocks Models with Connectors lt 1 gt lt 3 gt lt 2 gt lt 4 gt ENG 2 S TMR PNP types are a available i k N C 3 HOLD py e 5 N C 6 COM S TMR D2 S TMR 7 BANK4 8 BANK2 HOLD D3 e Applicable Connector Sold separately RESET XG4M 1030 OMRON NIC e Special Cable Sold separately K32 DICN OMRON COM XG4M 1030 with 3 m cable RESET D4 BCD Output Cable K32 BCD Connected device end COMMON K3HB end PLC display device etc OVER DATA VALID HH jo D 1 p 300 mm 38 mm 46 5 mm Cover HDR E50LPA5 manufactured by Honda Tsushin Co Ltd Cover Connector HDR E50MAG1 manufactured by Honda Tsushin Co Ltd POLARITY HH H D sub connector 37 pin female PASS L 17JE 37H 1A manufactur
18. he following three functions for receiving and displaying input pulses F1 Individual inputs F2 Phase differential inputs F3 Pulse counting input Filters Average Processing Aluti bk Aub a Average processing of input signals with extreme changes or noise smooths out the display and makes control stable Input Types Ln EA un ktb Specify the types of sensor connected to input A and input B OMRON Input Compensation ALZA Ae Zb The frequency is forced to zero if there is no pulse input for a set period Key Operations The present measurement value can be used as a scaling value Key Protection Key protection restricts level or parameter changes using the keys to prevent unintentional key operations and malfunctions Auto zero Times Outputs Comparative Output Pattern PIH da Standard zone and level comparative output patterns can be selected for comparative outputs Hysteresis HYS Prevents comparative outputs from chattering when the measurement value fluctuates slightly near the set value Output Refresh Stop o 5E P Holds the output status when a comparative result output other than PASS turns ON PASS Output Change BRES Comparative results other than PASS and error signals can be output from the PASS output terminal Output OFF Delay aFF d Delays turning OFF comparatives for a set period This can be used to provide sufficient time to read the comparative output ON status whe
19. he unit sticker sheets provided Sasa sss saa Sasa brs asa rasa basa sass as as a VIA N Al 6 J Pal o S N m w cm Ela min mm ep y y Z j j y 9 7 y 9 4 4 7 9 9 y 4 7 j VA mV mA Hz psa LCD Field of Vision The K3HB is designed to have the best visibility at the angles shown in the following diagram Note For measurements for commercial purposes be sure to use the unit required by any applicable laws or regulations 10 Rubber Packing Sold Separately K32 P1 If the rubber packing is lost or damaged it can be ordered using the following model number K32 P1 Depending on the operating environment deterioration contraction or hardening of the rubber packing may occur and so in order to ensure the level of waterproofing specified in NEMA4 periodic replacement is recommended Note Rubber packing is provided with the Controller OMRON Main Functions K3HB R E Main Functions and Features Measurement Function I The K3HB R has the following six functions for receiving and displaying input pulses F1 Rotation rpm circumferential speed F2 Absolute ratio F3 Error ratio F4 Rotational difference F5 Flow rate ratio F6 Passing time The K3HB P has the following six functions for receiving and displaying input pulses F1 Passing speed F2 Cycle F3 Time difference F4 Time band F5 Measuring length F6 Interval The K3HB C has t
20. lly or as sets CSM_K3HB R_DS_E_ 9 _ 1 Base Units Base Units with Optional Boards K3HB R LIL K3HB R I TIL 1 5 1 234 5 1 Input Sensor Code 2 Sensor Power Supply Output Type Code NB NPN input voltage pulse input None None PB PNP input CPA Relay output PASS SPDT Sensor power supply 5 Supply Voltage 12 VDC 10 80 mA See note 1 100 240 VAC 100 to 240 VAC L1A Linear current output 0 to 20 or 4 to 20 mA DC Sensor power supply 12 VDC 10 80 mA See note 2 L2A Linear voltage output 0 to 5 1 to 5 or O to 10 VDC Sensor power supply 12 VDC 10 80 mA See note 2 24 VAC VDC 24 VAC VDC Optional Boards A Sensor power supply 12 VDC 10 80 mA FLK1A Communications RS 232C Sensor power suppl Sensor Power Supply Output Boards 12 VDC 10 a mA ee note 2 P PES FLK3A Communications RS 485 Sensor power supply K33 _ 12 VDC 10 80 mA See note 2 2 3 Relay Transistor Output Type Code None None Relay Transistor Output Boards C1 Relay contact H L SPDT each C2 Relay contact HH H LL L SPST NO each K34 T1 Transistor NPN open collector HH H PASS L LL ai T2 Transistor PNP open collector HH H PASS L LL 3 BCD BCD output transistor output NPN open collector HH H PASS L LL DRT DeviceNet See note 2 Event Input Boards A Special BCD Output Cable sold separately is required 4 Event Input Type Code K35 _ None None 4 ile 5 inputs M3 terminal blocks NP
21. n the comparative result changes at short intervals shot Output Ea Turns ON the comparative output for a specific time Output Logic AWE n Reverses the output logic of comparative results Startup Compensation Timer ERT Measurements can be stopped for a set time using an external input Output Test FESE Output operation can be checked without using actual input signals by using the keys to set a test measurement value ER N 5E L L 5Etu LSEEH LSEEL A current or voltage proportional to the change in the measurement value can be output Stdby The comparison outputs can be kept OFF until the measurement value enters the PASS range Standby Sequence ALL DIMENSIONS SHOWN ARE IN MILLIMETERS K3HB R Display DIES EWAVEVUC MSI Yel eam of GP The display value can be set to the present value the maximum value or the minimum value DENA mH OL Or The present value display color can be set to green or red The color of the present value can also be switched according to the comparative output Display Refresh Period fax When the input changes rapidly the display refresh period can be lengthened to control flickering and make the display easier to read Position Meter PaS t PaS H PoS t The present measurement value can be displayed as a position in relation to the scaling width on a 20 gradation position meter GCE SAG PS AY PS bo PS bY The input signal can be converted and
22. nges are made However some specifications of the products may be changed without any notice When in doubt special model numbers may be assigned to fix or establish key specifications for your application on your request Please consult with your OMRON representative at any time to confirm actual specifications of purchased products DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes even when tolerances are shown PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty It may represent the result of OMRON s test conditions and the users must correlate it to actual application requirements Actual performance is subject to the OMRON Warranty and Limitations of Liability ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate however no responsibility is assumed for clerical typographical or proofreading errors or omissions 2012 4 In the interest of product improvement specifications are subject to change without notice OMRON Corporation Industrial Automation Company http www ia omron com c Copyright OMRON Corporation 2012 All Right Reserved
23. rea 2 blocks 60 words max Output area 1 block 29 words max The first word in the area is always allocated for the Output Execution Enabled Flags Message Explicit message communications communications CompoWay F communications commands can be executed using explicit message communications Connection methods Combination of multi drop and T branch connections for trunk and drop lines DeviceNet 500 250 or 125 Kbps automatic follow up Special 5 wire cable 2 signal lines 2 power supply lines 1 shield line CAE EE Baud rate Network length Drop line length Total drop line length max max max 500 Kbps 100 m max 6 m max 39 m max 100 m max 250 Kbps 100 m max 6 m max 78 m max 250 m max 125 Kbps 100 m max 6 m max 156 m max 500 m max The values in parentheses are for Thick Cable Supplied from DeviceNet communications connector OMRON K3HB R OMRON K3HB R Connections E External Connection Diagrams Terminal Arrangements Note Refer to nternal Block Diagram on page 12 for information on isolation A A Operating Power Supply j 100 to 240 VAC 24 VAC VDC JJ a e i wae Le E FN WN et 7 r cor E a z tea as a RT ET Kes Ke x AN Sy PAAA j Si E Co deee sn lt NIA mia S FaN Ly N y FAN AN Kad Zen TN im P AA EA R ca too a i 1 SY Y SY ze ae ea AG rej Re OOA WAN Ch
24. s circuit cos 0 4 Maximum load current 30 YOC UREE MS Leakage current 100 uA max Rated load 5 A at 250 VAC 1 A at 250 VAC 5 A at 30 VDC 1 A at 30 VDC Mechanical life 5 000 000 operations expectancy Electrical life 100 000 operations expectancy Linear Output C iem Outputs 010 20 mA 41020 mA 01 10V Allowable load impedance 500 0 max Resolution si Resolution _ Approx 10 000 Output error 0 5 FS 0 5 FS 0 15 V for 1 V or less and no output for 0 V Serial Communications Output BCD Output I O Ratings Item Type RS 232C RS 485 Input Signal Logic Negative Communications method Half duplex O signal name ltem Rating _ Synchronization method Start stop synchronization asynchronous input signal No voltage Baud rate 0600719200 3840 bps Input current for no voltage input Signal level ON voltage OFF voltage Maximum load voltage 24 VDC POLARITY OVER Maximum load current 10 mA DATA VALID Refer to the K3HB Communications User s Manual Cat No N129 for details on serial and DeviceNet communications OMRON K3HB R DeviceNet Communications Supported _ Remote I O Master Slave connection polling bit strobe COS cyclic communications communications Conforms to DeviceNet communications standards I O allocations Allocate any I O data using the Configurator Allocate any data such as DeviceNet specific parameters and variable area for Digital Indicators Input a
25. some examples of applications for which particular attention must be given This is not intended to be an exhaustive list of all possible uses of the products nor is it intended to imply that the uses listed may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equipment and installations subject to separate industry or government regulations Systems machines and equipment that could present a risk to life or property Please know and observe all prohibitions of use applicable to the products NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user s programming of a programmable product or any consequence thereof Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons It is our practice to change model numbers when published ratings or features are changed or when significant construction cha
26. value and When changing a set to change the actual minimum value and to value this key is used value reset the maximum and to move along the When a measurement minimum values digits value is displayed this key is used to execute or clear the forced zero function or to execute teaching OMRON K3HB R E Dimensions Terminal cover included Character Size for Main Display mm Panel Cutout Dimensions PV display SV display ae g i 120 min Mounting Recommended Panel Thickness 1 to 8mm Mount the product horizontally DeviceNet models 97 mm Terminal M3 Terminal Cover Accessory Wiring Precautions Mounting Method e For terminal blocks use the crimp terminals suitable for M3 screws 1 Insert the KSHB into the mounting cutout in the panel e Tighten the terminal screws to the recommended tightening torque 2 Insert watertight packing around the Unit to make the mounting of approx 0 5 N m watertight e To prevent inductive noise separate the wiring for signal lines from Watertight that for power lines packing Wiring e Use the crimp terminals suitable for M3 screws shown below l 5 8 mm max h d E 5 8 da 3 Insert the adapter into the grooves on the left and right sides of the rear case and push until it reaches the panel and is fixed in Unit Stickers included place e No unit stickers are attached to the Digital Indicator e Select the appropriate units from t